Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. What is the principal characteristic of class 1 dangerous goods?
Your Answer: (Not answered)
Correct Answer: C (Explosives, with mass explosion, projection or fire hazard)
💡 Class 1 of the IMDG Code covers explosives, including substances with mass explosion, projection or fire hazard, distinguished from flammable liquids (class 3), oxidisers (class 5) and radioactive material (class 7).
✗
Question 2. What does SOLAS IV/4 require regarding the independence of means for transmitting distress alerts?
Your Answer: (Not answered)
Correct Answer: B (At least two separate and independent means of transmitting a distress alert)
💡 SOLAS IV/4 requires the ship to be capable of transmitting distress alerts by at least two separate and independent means, so that failure of one device does not prevent the alert.
✗
Question 3. Besides the muster station, what else must the muster list specify?
Your Answer: (Not answered)
Correct Answer: D (The specific duty assigned to each crew member in an emergency)
💡 SOLAS III/37 requires the muster list to specify the duty of each crew member in an emergency and the muster station, and to identify the crew assigned to each survival craft.
✗
Question 4. The fire main pressure gauge shows an abnormally low pressure. What is the concern?
Your Answer: (Not answered)
Correct Answer: C (It may indicate reduced pump performance, leakage or a valve not properly opened and the cause should be established)
💡 Abnormally low pressure in the fire main may result from reduced fire pump performance, leakage in the piping or valves, a valve not correctly opened or a problem on the suction side. It would mean insufficient pressure at the jets in a fire, so the cause should be established and dealt with at once, as this is a deficiency that may affect firefighting capability.
✗
Question 5. Which statement about cooperation with a marine casualty investigation is correct?
Your Answer: (Not answered)
Correct Answer: C (Provide information truthfully, preserve the scene and evidence and cooperate, without falsifying or concealing)
💡 In a marine casualty investigation the ship should provide information truthfully, preserve the scene and evidence such as VDR data, the official log book, bell and engine movement records and pollution samples, and cooperate. Falsifying, concealing or destroying evidence is a serious violation with legal consequences.
✗
Question 6. Emergency lighting batteries are found of insufficient capacity so that the lights cannot last the required time after a power failure. The finding is?
Your Answer: (Not answered)
Correct Answer: A (Emergency lighting cannot last the required duration, a deficiency affecting escape and operational safety)
💡 Emergency lighting, including the emergency source of power, must last the required duration after the main power fails so as to light escape routes, muster stations, engine room escapes and essential operations. Insufficient capacity defeats this function and is a deficiency to be corrected.
✗
Question 7. Under the ISM Code, the company shall designate person(s) (DPA) to be responsible for:
Your Answer: (Not answered)
Correct Answer: C (linking the company with the ship on safety and pollution prevention matters)
💡 SOLAS IX/6: the company shall designate person(s) (DPA) to link the company with the ship on safety and pollution prevention matters.
✗
Question 8. What is required for maintenance and inspection of radio equipment?
Your Answer: (Not answered)
Correct Answer: A (Periodic inspection and maintenance to keep it ready for use)
💡 Periodic inspection and maintenance to keep it available at all times.
✗
Question 9. What is the purpose of a bulk carrier's Loading Manual?
Your Answer: (Not answered)
Correct Answer: D (It provides the permissible stresses, stability, shear force and bending moment data for loading conditions, guiding safe loading and ballasting)
💡 Under SOLAS XII/11 and related requirements a bulk carrier should carry an approved Loading Manual stating the permissible stresses, stability, shear force and bending moment data for loading conditions and guidance on ballasting and loading sequence, enabling the crew to prepare the loading plan and check stress and stability, preventing overloading and structural damage.
✗
Question 10. Bulk carriers required to be fitted with water level detectors are those of:
Your Answer: (Not answered)
Correct Answer: D (500 GT and above)
💡 SOLAS XII/12: bulk carriers of 500 GT and above shall be fitted with water level detectors in cargo holds.
✗
Question 11. What should be done about a failed water ingress detector on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (Repair promptly and, pending repair, increase manual checks such as sounding the bilges, with records kept)
💡 A failed water ingress detector should be repaired as soon as possible and, pending repair, manual checks increased, such as periodic sounding of holds, ballast tanks and bilges, with the failure and the temporary measures recorded. Switching the system off would remove the warning of flooding and is a serious deficiency.
✗
Question 12. What is the capacity requirement for survival craft on a passenger ship?
Your Answer: (Not answered)
Correct Answer: A (Each side must accommodate all persons on board, with additional liferafts as prescribed)
💡 SOLAS III requires the survival craft on each side of a passenger ship to accommodate all persons on board, with additional liferafts as prescribed, so all can escape even if one side is unusable.
✗
Question 13. How should medical advisory services be used?
Your Answer: (Not answered)
Correct Answer: B (Contact a shore-based medical advisory service by radio or satellite for guidance when a crew member is ill or injured)
💡 SOLAS and the MLC require the ship to contact a shore-based medical advisory service such as a TMAS by radio, satellite or other means for professional guidance when needed, recording the consultation and the treatment given. Prompt advice on an ocean passage markedly improves the outcome.
✗
Question 14. What do SOLAS V and COLREG require when navigating in a narrow channel?
Your Answer: (Not answered)
Correct Answer: A (Keep as near to the outer limit on the starboard side as is safe and practicable, at a safe speed with an adequate look-out)
💡 COLREG Rule 9 requires a vessel in a narrow channel to keep as near to the outer limit on her starboard side as is safe and practicable, at a safe speed with an adequate look-out. High speed or occupying any part of the channel greatly increases the risk of collision.
✗
Question 15. What is required in managing certificates of competence?
Your Answer: (Not answered)
Correct Answer: A (Ensure they are valid and appropriate to the position held and produce them for port State inspection as required)
💡 The certificates of competence, training certificates and medical certificates of the crew should be kept valid and appropriate to the positions held, kept safely on board and produced at inspection. Expired certificates or a mismatch with the position held is a serious deficiency and may lead to the ship being detained or the crew member being required to be replaced.
✗
Question 16. Into how many classes does the IMDG Code divide packaged dangerous goods?
Your Answer: (Not answered)
Correct Answer: D (Nine)
💡 The IMDG Code divides packaged dangerous goods into nine classes by hazard type, for example Class 1 explosives, Class 2 gases and Class 3 flammable liquids. The number is fixed at nine.
✗
Question 17. A safety protection device of the main propulsion plant, such as the overspeed trip, is found bypassed in the engine room. The finding is?
Your Answer: (Not answered)
Correct Answer: D (Bypassing a safety protection device is a serious violation that may cause machinery casualties and lead to detention)
💡 Safety protection devices such as the overspeed trip and low lubricating oil pressure trip of the main engine are used to reduce speed or shut down automatically in abnormal conditions, protecting machinery and personnel. Bypassing them removes the protection and may cause damage to the main engine or even an engine room casualty. It is a serious violation that may normally lead to detention.
✗
Question 18. What is required when using electrical tools in a paint locker?
Your Answer: (Not answered)
Correct Answer: A (Confirm adequate ventilation and vapour concentration within safe limits and use explosion-protected or intrinsically safe tools, restricting the work if necessary)
💡 Flammable vapour may accumulate in a paint locker. Before using electrical or spark-producing tools, adequate ventilation and vapour concentration within safe limits should be confirmed and explosion-protected or intrinsically safe tools used, with the work prohibited inside the locker if necessary.
✗
Question 19. What is the initial response of the officer of the watch in an emergency?
Your Answer: (Not answered)
Correct Answer: C (Take the necessary action immediately to avoid danger and inform the master at once, without delay)
💡 STCW requires the officer of the watch in an emergency to take immediate action to avoid danger and to inform the master at once. Delay to seek instructions is often the reason an incident escalates.
✗
Question 20. What securing is required for vehicles carried as ro-ro cargo?
Your Answer: (Not answered)
Correct Answer: A (Secure using the lashings or chains specified in the securing manual, confirming brake and gear status)
💡 SOLAS and the CSS Code require ro-ro cargo to be secured with the lashing straps, chains or dedicated devices specified in the securing manual, with the vehicle confirmed braked and in a suitable gear and its fuel and battery condition acceptable, preventing movement and collision during the voyage.
✗
Question 21. Which systems shall be used to receive navigational warnings?
Your Answer: (Not answered)
Correct Answer: C (Maritime safety information systems such as NAVTEX and SafetyNET)
💡 Systems such as NAVTEX and SafetyNET.
✗
Question 22. What measures do SOLAS and the IMSBC Code require for solid bulk cargoes liable to self-heat or release harmful gas?
Your Answer: (Not answered)
Correct Answer: A (Obtain full cargo information before loading, increase ventilation and gas testing and restrict entry into the holds)
💡 The IMSBC Code requires precautions for cargoes liable to self-heat or release harmful gas: full cargo information, increased ventilation and gas testing, restricted entry into the holds and emergency preparation, preventing spontaneous combustion, poisoning or explosion.
✗
Question 23. In severe weather, what measures may be taken to reduce cargo shifting and hull stress?
Your Answer: (Not answered)
Correct Answer: C (Adjust course and speed to ease rolling and slamming, check cargo securing and alter course to shelter if necessary)
💡 In severe weather the course and speed may be adjusted to ease rolling, pitching and slamming, cargo and deck fittings' securing checked and reinforced, the course altered flexibly to seek shelter, and stability and hull stress closely monitored. Driving fast through severe conditions worsens hull stress and cargo shifting.
✗
Question 24. For the discharge of bilge water treated by an oily water separator, what is the general oil content limit?
Your Answer: (Not answered)
Correct Answer: B (15 parts per million)
💡 Under MARPOL Annex I, bilge water treated by an oily water separator may generally be discharged only if its oil content does not exceed fifteen parts per million, with the 15ppm alarm and automatic stopping device. Tankers are subject to stricter distance and monitoring requirements.
✗
Question 25. Navigation publications required under SOLAS include:
Your Answer: (Not answered)
Correct Answer: C (charts, sailing directions and notices to mariners)
💡 SOLAS V/27 requires adequate charts, nautical publications and notices to mariners.
✗
Question 26. How must a ship respond to an increase in the security level?
Your Answer: (Not answered)
Correct Answer: C (Implement the additional measures for that level in the ship security plan and inform the crew and relevant parties)
💡 When the security level is raised the ship must apply the measures for that level in the ship security plan, such as tighter access control, monitoring of restricted areas, additional patrols, searching baggage and cargo and coordinating with the port facility security officer, informing the crew and relevant parties and reporting to the company where necessary.
✗
Question 27. What is the function of the hydrostatic release unit of an inflatable liferaft?
Your Answer: (Not answered)
Correct Answer: D (To release the raft automatically and allow it to inflate when the ship sinks to a given depth)
💡 The hydrostatic release unit operates at a set depth, cutting the painter and freeing the raft so that it floats free and inflates automatically. It does not add buoyancy nor hold the raft to the ship.
✗
Question 28. What fire rating does SOLAS normally require for the boundaries of main vertical zones?
Your Answer: (Not answered)
Correct Answer: B (A-60 class)
💡 SOLAS requires the boundaries between main vertical zones to be class A-60 divisions, confining a fire to the zone in which it starts and preventing spread to adjacent zones.
✗
Question 29. What is required for backup power of the firefighting system?
Your Answer: (Not answered)
Correct Answer: C (The emergency fire pump must have a source of power independent of the main fire pumps, so water is available on a blackout or machinery space fire)
💡 SOLAS requires the emergency fire pump to be independently driven, such as by a dedicated diesel engine or an independent power supply, so that it can still supply water if a blackout or a fire in the machinery space puts the main fire pumps out of action. It is essential to the redundancy of the firefighting system.
✗
Question 30. For passenger ships of less than 4 000 GT, the number of independently driven fire pumps required is:
Your Answer: (Not answered)
Correct Answer: C (not less than 2)
💡 SOLAS II-2/10 requires at least two independently driven fire pumps for passenger ships of less than 4 000 GT.
✗
Question 31. What does 'Administration' mean in SOLAS?
Your Answer: (Not answered)
Correct Answer: A (The Government of the State whose flag the ship is entitled to fly)
💡 It means the Government of the flag State.
✗
Question 32. For a ship without an approved treatment plant, what is the general distance requirement for the discharge of sewage?
Your Answer: (Not answered)
Correct Answer: C (Beyond 12 nautical miles from the nearest land and at the specified speed)
💡 Under MARPOL Annex IV, where no approved treatment plant is fitted, sewage may generally be discharged beyond twelve nautical miles from the nearest land and subject to speed and other conditions, while a ship with an approved plant may discharge closer when the conditions are met. Port States may also have stricter local rules.
✗
Question 33. What special stowage requirements apply to ships loading explosives?
Your Answer: (Not answered)
Correct Answer: B (Keep them away from heat, sources of ignition and accommodation as the IMDG Code requires, with special protection and segregation)
💡 The IMDG Code sets strict requirements for the stowage of class 1 explosives: away from the machinery space, heat and accommodation, segregated from incompatible goods, with special measures for explosion-protected electrical equipment, fire protection and security, and subject to approval by the port authority.
✗
Question 34. What does SOLAS address regarding gravity davits?
Your Answer: (Not answered)
Correct Answer: B (The craft must be launched by gravity without power and capable of being released from within the craft)
💡 SOLAS requires a gravity davit to launch the craft by gravity without power and to be capable of release from within the craft, so that abandonment can still be carried out if power is lost or personnel are dispersed.
✗
Question 35. The watertight door indicator showed a door open while it was in fact closed. What is the finding?
Your Answer: (Not answered)
Correct Answer: B (A deficiency; the indicator must accurately reflect the actual status, as a false indication misleads the assessment of watertight integrity)
💡 The watertight door indicator on the bridge must accurately reflect the actual open or closed status. A false indication would lead the watchkeeper to a wrong appreciation of watertight integrity and to incorrect measures after damage, so it is a deficiency affecting safety.
✗
Question 36. What does SOLAS address regarding drainage of ro-ro spaces?
Your Answer: (Not answered)
Correct Answer: A (Effective drainage removing firefighting water and leaked oil promptly)
💡 SOLAS requires ro-ro spaces to have effective drainage and storage arrangements able to remove firefighting water and leaked oil promptly, preventing free surface from affecting stability and reducing the risk of oil spreading the fire.
✗
Question 37. What are the key points in lowering a lifeboat during an abandon ship drill?
Your Answer: (Not answered)
Correct Answer: A (Check the brake and release gear, lower under the procedure and take account of the ship's condition)
💡 Lowering a lifeboat in a drill requires checking the brake and release gear, lowering under the procedure with account taken of list and sea conditions and the work done by not fewer than two persons. Rapid release or solo operation is a principal cause of casualties in drills.
✗
Question 38. What is the purpose of self-closing doors on escape routes?
Your Answer: (Not answered)
Correct Answer: B (To block the spread of smoke and flame)
💡 They block smoke and flame from spreading.
✗
Question 39. How does a non-conformity differ from an accident under the system?
Your Answer: (Not answered)
Correct Answer: D (a non-conformity being a state in which a requirement is not met, an accident an event that has caused injury, loss or pollution, and both, with near misses, to be reported and looked into)
💡 The non-conformity says a requirement has not been met: an entry missing from the record book, a drill or a course not done as planned, a survey overdue, the procedure on paper and another way on board, an observation from the last audit left unclosed. None of these has yet harmed anyone and all of them call for correction. The accident is named by what it did - injury, loss or pollution has in fact happened. Both are to be reported, looked into for cause and corrected, and the inquiry is meant to end at the management system rather than at the statement that a man handled it badly, which is also why the hazardous occurrence is listed by itself: the close run that did no harm is precisely the accident that has not yet happened. Downgrading whatever did no damage to a non-conformity, or holding that a departure in how work is done is not one either, takes the edge off the statistics and leaves the review with nothing to decide on.
✗
Question 40. What is required in setting the safety contour on ECDIS?
Your Answer: (Not answered)
Correct Answer: D (Set it in accordance with the ship's draught and the required under-keel clearance so that it reflects the actual safe depth)
💡 The safety contour and safety depth on ECDIS should be set according to the ship's draught, her under-keel clearance policy and the depths of the area, so that the system alarms accurately when approaching shoal water. An unsuitable default setting may make the alarm ineffective or cause constant false alarms.
✗
Question 41. What is the required interval for enclosed space entry and rescue drills on a cargo ship?
Your Answer: (Not answered)
Correct Answer: D (At least once every two months)
💡 Under SOLAS III/19 enclosed space entry and rescue drills should be held at least once every two months. The requirement addresses the high risk of enclosed space work, making the crew familiar with the testing, permit, attendant and rescue procedures before entry.
✗
Question 42. In the event of an incident involving dangerous goods, the ship shall:
Your Answer: (Not answered)
Correct Answer: D (report in accordance with the IMDG Code procedures and take emergency measures)
💡 SOLAS VII/4 requires reporting in accordance with IMDG Code procedures and emergency measures.
✗
Question 43. When ECDIS is used to satisfy the carriage of charts requirement, the ship must also have:
Your Answer: (Not answered)
Correct Answer: A (Appropriate back-up arrangements)
💡 SOLAS V/19: ECDIS may satisfy chart carriage only if appropriate back-up arrangements are provided.
✗
Question 44. What shall a B-class division satisfy?
Your Answer: (Not answered)
Correct Answer: D (Prevent passage of flame for a stated time and of smoke)
💡 B-class divisions prevent passage of flame for the stated time and of smoke.
✗
Question 45. What monitoring of cargo temperature and humidity is required?
Your Answer: (Not answered)
Correct Answer: D (Measure and record hold temperature and humidity periodically as the cargo requires, dealing with abnormal heating or condensation promptly)
💡 For cargoes liable to self-heat, heat or sensitive to moisture, such as coal, grain and certain chemicals, the hold temperature and humidity should be measured and recorded periodically, and abnormal temperature rise or condensation investigated, whether from self-heating or incorrect ventilation, with ventilation or other measures taken.
✗
Question 46. What preparation is required after receiving a warning of severe weather?
Your Answer: (Not answered)
Correct Answer: B (Assess the effect on the route, secure cargo, check and close watertight arrangements and consider altering course and speed)
💡 On receiving a warning of severe weather, its effect on the route should be assessed and cargo securing reinforced, watertight arrangements such as ventilators and doors checked and closed and ballast, course and speed adjusted in advance, avoiding losses from defects exposed in heavy weather.
✗
Question 47. How does the scope of the renewal survey compare with that of an annual survey?
Your Answer: (Not answered)
Correct Answer: B (The renewal survey is more comprehensive, including detailed examination of structure, machinery and equipment)
💡 SOLAS requires the renewal survey to include a comprehensive inspection of structure, machinery and equipment with the prescribed items, whereas the annual survey is a more general overall inspection.
✗
Question 48. What does SOLAS require of the water ingress detection and alarm system on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: B (Detection in cargo holds, ballast tanks and dry spaces, with an audible and visual alarm on the bridge)
💡 SOLAS XII/12 requires a bulk carrier to have water ingress detection in cargo holds, ballast tanks and dry spaces, with an audible and visual alarm on the bridge, enabling the watchkeeper to detect flooding promptly and act.
✗
Question 49. Within what time shall the emergency generator start automatically and supply power?
Your Answer: (Not answered)
Correct Answer: A (30 seconds)
💡 Within 30 seconds.
✗
Question 50. How many means of escape, widely separated, shall be provided on each deck in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: B (Two)
💡 SOLAS II-2/13: at least two widely separated means of escape shall be provided on each deck.
✗
Question 51. What are the usual transmit power settings of a ship's VHF radiotelephone?
Your Answer: (Not answered)
Correct Answer: A (1 watt (low) and 25 watts (high))
💡 A ship's VHF normally has two settings, one watt for low power and twenty-five watts for high power, low power being used for short-range communication to reduce interference and high power for long range or distress communication to ensure coverage. Selecting the right setting is a basic watchkeeping requirement.
✗
Question 52. The radar and ARPA are found without the required periodic performance tests and records. The finding is?
Your Answer: (Not answered)
Correct Answer: A (Radar and ARPA should be tested and recorded periodically; failure is a navigational equipment management deficiency)
💡 Radar and ARPA are key equipment for collision avoidance and positioning and should undergo periodic performance tests, such as display, range, gain, and ARPA acquisition and tracking, with records kept, to confirm they are in good working order. Without testing or records their reliability cannot be shown. It is a deficiency to be corrected.
✗
Question 53. Within what period before departure shall the steering gear be tested?
Your Answer: (Not answered)
Correct Answer: C (Within 12 hours)
💡 SOLAS V/25: the steering gear shall be tested within 12 hours before departure.
✗
Question 54. What is the purpose of isolation valves on the fire main required by SOLAS?
Your Answer: (Not answered)
Correct Answer: B (To isolate a damaged section so the rest of the main can continue to supply water)
💡 SOLAS requires isolation valves on the fire main so that if a section, for example in the machinery space, is damaged, it can be isolated while the remainder still supplies the hydrants, preserving at least part of the firefighting capability.
✗
Question 55. What is required for the display of alarms from a fixed fire detection and fire alarm system?
Your Answer: (Not answered)
Correct Answer: A (The alarm must be displayed on the bridge or at a continuously manned central control station and indicate the space concerned)
💡 SOLAS requires fire alarms to be displayed on the bridge or at a continuously manned central control station and to indicate the space in which the alarm was initiated, so the fire can be located at once.
✗
Question 56. How does SOLAS I/8 treat passenger ship certification differently from cargo ships?
Your Answer: (Not answered)
Correct Answer: C (The passenger ship safety certificate is valid for not more than 12 months)
💡 SOLAS I/8 limits the passenger ship safety certificate to 12 months, whereas cargo ship certificates are generally valid for not more than five years. The periods differ.
✗
Question 57. What are the approval and use requirements for the Cargo Securing Manual?
Your Answer: (Not answered)
Correct Answer: C (It should be approved by the Administration and carried on board, the crew securing cargo and inspecting the securing equipment as it requires)
💡 Under SOLAS V/5 and related requirements the relevant ships should carry a Cargo Securing Manual approved by the Administration, containing the list, strength, arrangement and use of the securing devices, the crew securing cargo as it requires and inspecting and maintaining the equipment at the required intervals, recording defects and repairs.
✗
Question 58. What does SOLAS address regarding sounding and observation arrangements for fuel oil tanks?
Your Answer: (Not answered)
Correct Answer: C (Safe and reliable measuring arrangements, preventing oil from overflowing or spraying out)
💡 SOLAS requires fuel oil tank measuring arrangements to be safe and reliable, such as self-closing sounding pipes or closed level gauges, preventing oil from overflowing or spraying onto hot surfaces during measurement and causing fire.
✗
Question 59. Stairways penetrating more than one deck within accommodation spaces shall generally be enclosed by:
Your Answer: (Not answered)
Correct Answer: A (A class divisions)
💡 SOLAS II-2/9 requires stairways penetrating two or more decks to be enclosed by A class divisions.
✗
Question 60. What must the cargo securing manual contain under SOLAS VI/5 and the CSS Code?
Your Answer: (Not answered)
Correct Answer: C (Securing methods for the various cargo units, specifications of securing equipment and methods of strength verification)
💡 SOLAS VI/5 and the CSS Code require the cargo securing manual to contain the securing methods for the various cargo units, the specification and number of securing devices, methods of strength verification and inspection requirements, for correct securing by the crew.
✗
Question 61. What does SOLAS address regarding the protection of stairway enclosures?
Your Answer: (Not answered)
Correct Answer: D (Stairways must be enclosed by class A or B divisions, preventing a chimney effect from accelerating fire and smoke spread)
💡 SOLAS requires enclosed stairways in accommodation spaces to be protected by class A or B divisions, preventing the stairwell from acting as a chimney that accelerates the upward spread of flame and smoke, and protecting the escape route.
✗
Question 62. What is required for checking the tightness of hatch covers on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Periodic inspection of seals, cleats and drain channels with a hose test to verify weathertightness)
💡 SOLAS requires the hatch covers of a bulk carrier to remain weathertight, with periodic checks of seal ageing, the effectiveness of cleats and the clearance of drain channels, and a hose test where necessary to verify tightness, preventing sea water from entering the holds and damaging structure and cargo.
✗
Question 63. What does SOLAS address regarding separation between the galley and the machinery space?
Your Answer: (Not answered)
Correct Answer: A (Class A divisions to prevent a fire in one spreading to the other)
💡 SOLAS requires class A divisions between high risk spaces such as the galley and the machinery space to prevent the spread of fire from one to the other. The galley has open flames and oil while the machinery space has fuel and hot surfaces, so reliable separation is essential where they adjoin.
✗
Question 64. From what tonnage shall a gyro compass be fitted?
Your Answer: (Not answered)
Correct Answer: A (150 GT and above)
💡 150 GT and above on international voyages.
✗
Question 65. Where must the muster list be posted?
Your Answer: (Not answered)
Correct Answer: A (On the bridge and in the spaces where emergency duties are assigned)
💡 The muster list is posted on the bridge and at each station where emergency duties are performed.
✗
Question 66. What is the correct practice for ventilating an enclosed space before entry?
Your Answer: (Not answered)
Correct Answer: C (Continuous mechanical ventilation, followed by testing to confirm acceptable readings before entry)
💡 Continuous mechanical ventilation should be carried out before entry, followed by gas testing, if necessary after a settling period, to confirm acceptable readings. Natural ventilation through an open hatch, or ventilating without testing, does not ensure safety.
✗
Question 67. Where should the fire control plan be stowed on board?
Your Answer: (Not answered)
Correct Answer: B (In a conspicuously marked weathertight enclosure outside the deckhouse, with a further copy on the bridge or equivalent position)
💡 SOLAS II-2/15 requires the fire control plan to be permanently stowed in a conspicuously marked weathertight enclosure outside the deckhouse, with another copy on the bridge or equivalent, for use by shore firefighters.
✗
Question 68. What type of seal is required for cable penetrations of a fire division?
Your Answer: (Not answered)
Correct Answer: D (An approved penetration seal whose fire rating is not less than the division penetrated)
💡 SOLAS requires cable penetration seals to be approved with a fire rating not less than that of the division penetrated, for example an A-60 rated seal where an A-60 division is crossed. Ordinary packing or expanding foam does not meet the fire and smoke requirements.
✗
Question 69. What are the requirements for the position of the satellite EPIRB on board?
Your Answer: (Not answered)
Correct Answer: C (Readily accessible, capable of floating free and activating automatically if the ship sinks)
💡 SOLAS requires the EPIRB to be mounted where it is readily accessible manually, will float free and activate automatically if the ship sinks. Keeping it locked in a room or drawer does not comply.
✗
Question 70. What does SOLAS emphasise in the launching and recovery of survival craft?
Your Answer: (Not answered)
Correct Answer: A (Operations must be carried out under safe conditions with adequate lighting and by persons familiar with the procedure)
💡 SOLAS requires launching and recovery to be conducted under safe conditions, with adequate lighting, by persons familiar with the procedure and equipment, to avoid casualties during drills.
✗
Question 71. What shall be the relationship between the main and emergency sources of power?
Your Answer: (Not answered)
Correct Answer: A (They are independent and the emergency source takes over automatically)
💡 They shall be independent and the emergency source shall take over automatically.
✗
Question 72. In a bridge design review for a new multi-purpose vessel the yard submits four statements: (1) five forward windows with frames kept as narrow as practicable; (2) a refrigeration compressor casing at the conning position blocking about 15 degrees ahead; (3) in ballast the sea surface ahead of the bow is not visible from the conning position; (4) fixed wipers with washing and defrosting on the forward windows. Which statements are non-compliant with SOLAS chapter V?
Your Answer: (Not answered)
Correct Answer: D (items 2 and 3)
💡 The permitted blind sector forward of the conning position is limited, so a 15-degree obstruction ahead is a classic layout error, and the field must be met in both loaded and ballast conditions — a bare claim that the bow can be seen is not enough. Narrow frames, fixed wipers and wash/defrost are what V/22 expects, so 1 and 4 comply.
✗
Question 73. What does SOLAS V/19.2.3 require for the heading indication of a ship?
Your Answer: (Not answered)
Correct Answer: B (A duly adjusted magnetic compass or other suitable means of determining and displaying the heading)
💡 SOLAS V/19.2.3 requires an adjusted magnetic compass or other approved means of determining and displaying heading. GPS gives course over ground and cannot replace heading indication.
✗
Question 74. Each firefighter's outfit shall consist of:
Your Answer: (Not answered)
Correct Answer: D (protective clothing, helmet, boots, gloves and breathing apparatus, etc.)
💡 SOLAS II-2/10: each firefighter's outfit shall consist of protective clothing, helmet, boots, gloves and breathing apparatus, etc.
✗
Question 75. A PSCO checked the chart updating of ECDIS. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: D (Electronic charts must be kept up to date and consistent with the ENCs in use)
💡 SOLAS requires the electronic charts used in ECDIS to be kept corrected to the latest state and consistent with the ENCs in use. Late updating means missing recent navigational warnings and increases the risk of grounding, a common deficiency.
✗
Question 76. When is the safety signal SECURITE used?
Your Answer: (Not answered)
Correct Answer: C (To broadcast navigational safety information such as a floating hazard or a gale warning)
💡 SECURITE is the safety signal, used to broadcast navigational safety information such as a hazard, a weather warning or a navigational warning. Its priority is lower than MAYDAY and PAN PAN but it is still safety traffic, and unrelated calls must not occupy the frequency.
✗
Question 77. What is the core requirement of SOLAS II-2/4.5.9 for the arrangement of fuel oil, lubricating oil and other flammable oils?
Your Answer: (Not answered)
Correct Answer: A (They shall be kept clear of hot surfaces and arranged and protected to prevent ignition)
💡 SOLAS II-2 requires flammable oils to be kept away from hot surfaces and protected against spraying onto sources of ignition.
✗
Question 78. For a cargo ship of 2000 GT and above, the auxiliary steering gear shall put the rudder over how quickly?
Your Answer: (Not answered)
Correct Answer: C (From 15° one side to 15° the other in not more than 30 seconds)
💡 SOLAS II-1/29: the auxiliary steering gear shall be capable of putting the rudder over in 30 seconds.
✗
Question 79. What verification of the effectiveness of rectification is required?
Your Answer: (Not answered)
Correct Answer: B (Verify through re-inspection, testing or practical demonstration, not merely by documents or undertakings)
💡 After rectification its effectiveness should be verified by actual re-inspection, testing equipment or observing the crew, such as re-testing after a repair or checking the crew's operation after training, with evidence that the deficiency has been removed. A plan or an undertaking does not show that the work is done.
✗
Question 80. What are the handling requirements when encountering heavy swell and seas?
Your Answer: (Not answered)
Correct Answer: A (Adjust course and speed so that the hull meets the seas at a suitable angle, avoiding a beam sea and direct head seas which cause damage)
💡 In heavy seas and swell the course and speed should be adjusted so the hull meets the seas at a suitable angle, normally obliquely, avoiding a beam sea which causes heavy rolling and cargo shift and direct head seas which cause violent pitching and slamming that damages the hull.
✗
Question 81. What are the duties of the deck watch during cargo operations on a tanker?
Your Answer: (Not answered)
Correct Answer: B (Monitor piping, valves and tanks, detecting leaks, overflow or abnormalities and taking action)
💡 During cargo operations on a tanker a deck watch must be maintained, monitoring pipeline joints for leakage, tank levels and pressures, overflow and unusual noise, with communication kept with the engine room and the terminal, so that abnormalities are detected and dealt with promptly.
✗
Question 82. How must alarms be handled at sea?
Your Answer: (Not answered)
Correct Answer: D (Establish the cause and deal with it promptly; alarms must not be silenced or inhibited at will)
💡 Every alarm, whether fire, machinery or water ingress, requires the cause to be established and appropriate action taken. It must not be silenced or inhibited at will for the sake of quiet. Inhibiting alarms conceals real faults, so that a genuine problem goes unnoticed.
✗
Question 83. Ships shall be provided with means to determine their position, which may include:
Your Answer: (Not answered)
Correct Answer: D (adequate means such as radar, ECDIS or GPS to fix position)
💡 SOLAS V/19 requires adequate means to determine the ship's position.
✗
Question 84. How do the fire protection requirements for the cargo area of a chemical tanker differ from those of an oil tanker?
Your Answer: (Not answered)
Correct Answer: D (The extinguishing medium must be chosen according to the properties of the chemicals carried, with water or foam prohibited for certain cargoes)
💡 Because chemicals vary greatly in reactivity, SOLAS and the IBC Code require the extinguishing medium to suit the cargo. Some cargoes react with water or liberate toxic gas, so water or foam is prohibited.
✗
Question 85. What does SOLAS address regarding the arrangement for boarding survival craft?
Your Answer: (Not answered)
Correct Answer: A (Boarding in order according to the list, with numbers not exceeding the rated capacity, avoiding crowding and overload)
💡 Boarding should follow the prepared list and order, with the number in each craft not exceeding the rated capacity and persons detailed to let go the lifelines, handle the boat and attend to casualties, avoiding confusion, crowding and overloading which would affect the safety of the craft.
✗
Question 86. What do COLREG and SOLAS require for overtaking in a narrow channel?
Your Answer: (Not answered)
Correct Answer: D (The overtaking vessel must obtain the agreement of the vessel being overtaken and keep a sufficient distance)
💡 COLREG Rule 9 requires a vessel intending to overtake in a narrow channel to obtain the agreement of the vessel to be overtaken, normally by VHF or sound signal, and to pass at a sufficient distance. Overtaking without agreement risks collision.
✗
Question 87. What is the purpose of the automatic closing and hold-back release arrangements of fire doors?
Your Answer: (Not answered)
Correct Answer: D (To enable the doors to be held open for passage in normal service and to close automatically on a fire alarm to maintain the fire division)
💡 Under SOLAS II-2/9 fire doors required to be self-closing should be fitted with automatic closing arrangements and, where necessary, hold-back release arrangements that release the door on detection of a fire. The door may be held open in normal service for passage and ventilation and closes automatically on a fire alarm to maintain the fire division. The arrangements should be tested regularly.
✗
Question 88. What do SOLAS and good practice require in preparation for mooring before berthing?
Your Answer: (Not answered)
Correct Answer: C (Station the mooring party in advance, prepare ropes and fenders and agree the mooring plan with the terminal)
💡 Before berthing, the mooring party should be stationed in advance, ropes and fenders prepared and the mooring plan agreed with the terminal, with the berth condition confirmed. Inadequate preparation leads to impact or a parted line during the operation.
✗
Question 89. In an overtaking situation, how are responsibility and duties allocated?
Your Answer: (Not answered)
Correct Answer: C (The overtaking vessel must keep out of the way and the overtaken vessel keeps her course and speed)
💡 Under the collision regulations the overtaking vessel must keep out of the way of the vessel being overtaken in all situations until finally past and clear, while the overtaken vessel keeps her course and speed. A vessel approaching from more than twenty-two point five degrees abaft the beam of the vessel ahead is overtaking.
✗
Question 90. What must the ship security plan contain under the ISPS Code?
Your Answer: (Not answered)
Correct Answer: A (The security organisation and duties, restricted areas, training of personnel, drills and security incident procedures)
💡 ISPS Code Part A/9 requires the ship security plan to cover the security organisation and duties, restricted areas and their control, personnel training and drills, and procedures for security incidents, subject to Administration approval.
✗
Question 91. What material and structural requirements apply to class A divisions?
Your Answer: (Not answered)
Correct Answer: A (They must be of steel or another approved equivalent material, suitably stiffened to maintain structural integrity)
💡 SOLAS requires class A divisions to be of steel or another approved equivalent material, suitably stiffened so that they retain structural integrity and prevent the passage of smoke and flame after the standard fire test.
✗
Question 92. The main functions of an Inmarsat ship earth station include:
Your Answer: (Not answered)
Correct Answer: C (distress alerting, communication and reception of maritime safety information)
💡 SOLAS IV/7 requires an Inmarsat ship earth station for distress alerting, communication and reception of MSI.
✗
Question 93. What is the basic requirement of SOLAS for protection against electric shock?
Your Answer: (Not answered)
Correct Answer: A (Live parts must be protected, and safety voltage or isolation used in hazardous locations)
💡 SOLAS requires exposed live parts to be protected and safety voltage or isolation and residual current protection to be used in damp or metal-enclosed locations, reducing the risk of electric shock.
✗
Question 94. What fire protection is required in the cargo area of a gas carrier?
Your Answer: (Not answered)
Correct Answer: A (Gas detection and alarm, intrinsically safe or explosion-protected electrical equipment and safety devices protecting the cargo containment system)
💡 SOLAS and the IGC Code require the cargo area of a gas carrier to have flammable gas detection and alarm, intrinsically safe or explosion-protected electrical equipment and devices protecting the pressure and temperature of the cargo containment system, preventing accumulation of leaks and overpressure.
✗
Question 95. What does SOLAS address regarding the quantity of extinguishing medium in a fixed system?
Your Answer: (Not answered)
Correct Answer: B (Calculated from the volume of the protected space with the prescribed margin)
💡 SOLAS requires the quantity of extinguishing medium to be calculated from the net volume of the protected space and to meet the prescribed minimum concentration and margin, ensuring an effective concentration after release.
✗
Question 96. Lifeboat and liferaft launching appliances shall be capable of operating when the ship is trimmed by:
Your Answer: (Not answered)
Correct Answer: A (not more than 10°)
💡 SOLAS III/16 requires launching appliances to operate with the ship trimmed up to 10° and listed up to 20°.
✗
Question 97. What is required when testing DSC or radio equipment in port?
Your Answer: (Not answered)
Correct Answer: A (Test on the prescribed channel or under the prescribed conditions, avoiding a false distress alert and taking precautions before testing)
💡 Testing radio equipment, especially DSC, should be carried out on the prescribed channel or under the prescribed conditions with precautions against transmitting a false distress alert, such as using the specific test setting and avoiding an actual distress alert. A false alert wastes search and rescue resources and may attract a penalty.
✗
Question 98. A ship of 3200 GT. Under SOLAS V/19, is a second radar required?
Your Answer: (Not answered)
Correct Answer: A (Yes; ships of 3000 GT and above must carry a second radar)
💡 SOLAS V/19 requires ships of 3000 GT and above to be fitted with a second radar operating independently. At 3200 GT the ship is above the threshold.
✗
Question 99. The navigation lights are found not to meet the required position, colour or arc of visibility. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Non-compliant navigation lights affect the ability of other ships to judge the situation, a deficiency to be corrected)
💡 The position, colour and arc of visibility of the navigation lights, such as masthead, sidelights and stern light, must meet the requirements so that other ships can judge the heading and movement of the vessel from the correct bearing and distance. Non-compliance may lead to misjudgement and increased risk of collision. It is a deficiency to be corrected.
✗
Question 100. What condition regarding the suction of the emergency fire pump does SOLAS address?
Your Answer: (Not answered)
Correct Answer: D (It must be capable of drawing water under all operating draughts and trims of the ship)
💡 SOLAS requires the emergency fire pump suction to be arranged so that water can be drawn under all operating draughts and trims. Otherwise it may fail in a particular condition, a common ground for detention.