Question 1. What does SOLAS require for quick closing valves in the fuel oil system of a machinery space?
Your Answer: (Not answered)
Correct Answer: A (Quick closing valves at fuel tank outlets and at fuel pumps, remotely operable from outside the space)
💡 SOLAS requires quick closing valves at fuel tank outlets and at fuel pumps, capable of remote operation from a readily accessible position, normally outside the space, so the fuel supply can be cut off rapidly in a machinery space fire.
✗
Question 2. What fire protection is required in the cargo area of a gas carrier?
Your Answer: (Not answered)
Correct Answer: A (Gas detection and alarm, intrinsically safe or explosion-protected electrical equipment and safety devices protecting the cargo containment system)
💡 SOLAS and the IGC Code require the cargo area of a gas carrier to have flammable gas detection and alarm, intrinsically safe or explosion-protected electrical equipment and devices protecting the pressure and temperature of the cargo containment system, preventing accumulation of leaks and overpressure.
✗
Question 3. Regarding the accuracy of AIS information, what does SOLAS V require for navigational data?
Your Answer: (Not answered)
Correct Answer: D (Voyage related static and dynamic data must be entered promptly and accurately)
💡 SOLAS V/19 requires the AIS static and dynamic data to be correct, with voyage information updated as circumstances change. Incorrect data misleads other ships and affects collision avoidance decisions.
✗
Question 4. In SOLAS I/2 the expression "upright position" is used to define which condition of the ship?
Your Answer: (Not answered)
Correct Answer: B (The reference condition with no heel, used for measuring freeboard and similar particulars)
💡 SOLAS and the Load Line Convention take the upright (no heel) condition as the datum for measuring moulded depth, freeboard and similar particulars, irrespective of the loading condition.
✗
Question 5. What is the basic principle for the provision of lifejackets?
Your Answer: (Not answered)
Correct Answer: D (One for every person on board, with additional ones for watchkeepers, remote locations and survival craft stations)
💡 Under SOLAS III/7 and III/32 a lifejacket should be provided for every person on board, with additional ones to meet the needs of watchkeeping positions, remote locations and survival craft stations, so that one can be obtained at any time and place.
✗
Question 6. Which tanks are normally excluded from ballast use?
Your Answer: (Not answered)
Correct Answer: C (Fuel, lubricating oil and fresh water tanks, preventing contamination and cross-connection)
💡 SOLAS and MARPOL prohibit fuel, lubricating oil and fresh water tanks from being used as ballast tanks, preventing ballast water from cross-connecting with oils and causing pollution, or oil entering the ballast system and affecting equipment. Dedicated ballast tanks and cargo oil tanks are treated separately under MARPOL.
✗
Question 7. What must the embarkation arrangements for survival craft satisfy?
Your Answer: (Not answered)
Correct Answer: C (All persons can be safely embarked and launched within the prescribed time)
💡 SOLAS III/11 requires embarkation arrangements enabling all persons to board and be launched safely within the prescribed time, including lighting, ladders and the arrangement of muster stations.
✗
Question 8. What is required for maintenance and inspection of radio equipment?
Your Answer: (Not answered)
Correct Answer: A (Periodic inspection and maintenance to keep it ready for use)
💡 Periodic inspection and maintenance to keep it available at all times.
✗
Question 9. What separation is required for the deck between accommodation spaces and a machinery space?
Your Answer: (Not answered)
Correct Answer: A (Normally A-60 class, protecting a high fire risk boundary)
💡 SOLAS requires A-60 class boundaries between category A machinery spaces and accommodation spaces. Because the fire risk in machinery spaces is high, the strongest protection is required to prevent spread to the accommodation.
✗
Question 10. What layers of protection do SOLAS and the IMO resolutions require for enclosed space entry?
Your Answer: (Not answered)
Correct Answer: B (Ventilation, testing, a permit, a standby person and rescue preparation forming a complete entry procedure)
💡 SOLAS and the IMO resolutions require a complete procedure for enclosed space entry: ventilation, testing, a permit, a standby person and rescue arrangements. The layers work together; no single measure ensures safety.
✗
Question 11. How should a deficiency concerning crew training found at a PSC inspection be rectified?
Your Answer: (Not answered)
Correct Answer: A (Organise targeted training and drills, assess the outcome and record it, revising the training plan if necessary)
💡 A training deficiency, such as unfamiliarity with equipment or unclear emergency duties, should be met by targeted training and practical drills, with the outcome assessed and records kept and the training plan and its execution analysed and revised, so that the problem is genuinely resolved.
✗
Question 12. What does SOLAS address regarding stopping machinery space ventilation fans?
Your Answer: (Not answered)
Correct Answer: D (Fans must be capable of remote stopping, with the control outside the space)
💡 SOLAS requires machinery space ventilation fans to be capable of being stopped remotely, with the control outside the space, working together with the closing of dampers to cut off the air supply quickly in a fire and prevent it from intensifying.
✗
Question 13. Each person in a lifeboat shall be provided with food of an energy value of not less than:
Your Answer: (Not answered)
Correct Answer: D (10 000 kJ)
💡 SOLAS III/34 requires food of not less than 10 000 kJ per person in a lifeboat.
✗
Question 14. What does sea area A4 cover?
Your Answer: (Not answered)
Correct Answer: A (The area outside sea areas A1, A2 and A3, principally polar waters with no satellite coverage)
💡 Sea area A4 means the area outside A1, A2 and A3, principally polar waters beyond Inmarsat coverage. It is not a collective term for all sea areas.
✗
Question 15. What should the crew do after the abandon ship alarm is sounded?
Your Answer: (Not answered)
Correct Answer: A (Act in accordance with the duties in the muster list, taking the designated items to the muster station and awaiting orders)
💡 On the abandon ship alarm the crew acts under the muster list: taking the designated emergency items such as lifejackets, certificates and the log and reporting to the muster station, with the master or the officer in charge deciding whether to abandon and the order of boarding. No one acts independently.
✗
Question 16. Navigation publications required under SOLAS include:
Your Answer: (Not answered)
Correct Answer: C (charts, sailing directions and notices to mariners)
💡 SOLAS V/27 requires adequate charts, nautical publications and notices to mariners.
✗
Question 17. Which statement about the use of weather routeing is correct?
Your Answer: (Not answered)
Correct Answer: D (The route should be chosen taking account of weather forecasts and the ship's condition, avoiding severe weather and monitoring the passage plan)
💡 Weather routeing should combine professional weather forecasts with the ship's condition, such as stability, cargo and draught, to choose a relatively safe route avoiding typhoons, heavy seas and severe weather, monitoring and adjusting the plan during the voyage. It is an aid, the final navigational decision being the master's responsibility.
✗
Question 18. What does the shipboard oil pollution emergency plan have the crew exercise in?
Your Answer: (Not answered)
Correct Answer: A (the alarm and the report when oil is seen, getting the gear out, working the containment and recovery, and who is to be told and what is said to them)
💡 The plan has to set out each step as the ship would take it: who sees it and when, how the source and position of the spill are judged, the order of raising the alarm and telling the bridge, the muster and the split of duties, what valves and pumps are worked on deck, where the boom and the absorbents live and who handles them, how the spread is held and the oil gathered, and then the report to the company, to the coastal State and to the port, its form and its timing, contact with the salvors and with other ships, the writing up and the look back afterwards. It is the exercise that puts these in the crew's hands: once a man has carried the gear and sent a practice report he knows what his own ship, at her speed and with her arrangement, can actually do. Exercises go best alongside the other drills and at the intervals the plan names, and what they show comes back into the plan and the training. A signature with no exercise, or another drill's record standing in for it, will not hold when the inspection asks or when the oil is on the water.
✗
Question 19. Which types of emergency source of power does SOLAS permit?
Your Answer: (Not answered)
Correct Answer: A (An emergency generator or a battery, supplying the emergency services for the prescribed period)
💡 SOLAS permits the emergency source to be an emergency generator or a battery. Where a battery is used its capacity must carry the emergency services, such as emergency lighting, communications and alarms, for the prescribed period.
✗
Question 20. A newly joined crew member is found not to have completed familiarisation training and records before the ship sailed. The finding is?
Your Answer: (Not answered)
Correct Answer: A (New crew should complete familiarisation before taking up duties; absence is a training deficiency)
💡 Before taking up duties on board a crew member should receive familiarisation training on the ship's life-saving and firefighting equipment, emergency duties and relevant procedures, with records kept. Absence leaves the crew member unable to act correctly in an emergency. It is a training and management deficiency to be corrected.
✗
Question 21. How many lifebuoys must be fitted with self-igniting lights under SOLAS III/7.1?
Your Answer: (Not answered)
Correct Answer: A (Not less than one half of the total number of lifebuoys)
💡 SOLAS III/7.1 requires not less than one half of the total lifebuoys to be fitted with self-igniting lights. The requirement for buoyant lifelines is a separate provision.
✗
Question 22. What does SOLAS V require when a ship enters a deep-water route?
Your Answer: (Not answered)
Correct Answer: A (To report to the appropriate authority as required and comply with the conditions of use)
💡 SOLAS V requires ships using deep-water routes to report as prescribed and comply with conditions such as under-keel clearance, so as to reduce the risk of grounding.
✗
Question 23. Three crew members were replaced during the voyage. What should be done with the muster list?
Your Answer: (Not answered)
Correct Answer: B (It must be amended without delay and re-posted so that new crew know their duties)
💡 SOLAS III/37 requires the muster list to be kept up to date as the crew changes and re-posted, so that every person on board can find his duty and muster station. An oral briefing or a log entry alone is not sufficient.
✗
Question 24. What shall be the relationship between the main and emergency sources of power?
Your Answer: (Not answered)
Correct Answer: A (They are independent and the emergency source takes over automatically)
💡 They shall be independent and the emergency source shall take over automatically.
✗
Question 25. For a cargo ship of less than 100 m in length, the minimum number of lifebuoys shall be:
Your Answer: (Not answered)
Correct Answer: C (8)
💡 SOLAS III/32 requires at least eight lifebuoys for cargo ships of less than 100 m in length.
✗
Question 26. What should be done first when a fire breaks out in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: C (Raise the alarm, organise evacuation and shut off ventilation to the area and, as required, the power)
💡 A fire in accommodation should first trigger the alarm, with evacuation and firefighting organised under the muster list, ventilation shut off as necessary to limit smoke spread and power controlled. Breaking in hastily admits air that feeds the fire and endangers personnel.
✗
Question 27. What cooperation with an external audit is required?
Your Answer: (Not answered)
Correct Answer: A (Provide documentation, records and the actual condition truthfully, arrange personnel to assist and explain the operation honestly, without concealing or falsifying)
💡 An external audit requires the system documentation, records and the actual condition of the ship to be provided truthfully, personnel arranged to assist and the operation explained honestly. Concealing problems, making up records at short notice or obstructing the audit is a serious breach and may lead to suspension or withdrawal of certificates.
✗
Question 28. What quality requirement applies to the foam concentrate of a fixed foam system?
Your Answer: (Not answered)
Correct Answer: B (It must be approved, used within its shelf life and periodically tested for performance)
💡 SOLAS and the related standards require approved foam concentrate used within its shelf life, with periodic sampling to verify expansion and extinguishing performance. Deteriorated or out-of-date concentrate will fail when needed.
✗
Question 29. For a cargo ship of 2000 GT and above, the auxiliary steering gear shall put the rudder over how quickly?
Your Answer: (Not answered)
Correct Answer: C (From 15° one side to 15° the other in not more than 30 seconds)
💡 SOLAS II-1/29: the auxiliary steering gear shall be capable of putting the rudder over in 30 seconds.
✗
Question 30. What is required for testing the emergency lighting system?
Your Answer: (Not answered)
Correct Answer: A (Periodic testing of automatic operation and duration, with records kept)
💡 SOLAS and good practice require periodic testing of the automatic operation of the emergency lighting and of its duration, for example by simulating failure of the main source, observing the lighting come on and timing it, verifying the prescribed period with records kept, preventing failure during an actual blackout.
✗
Question 31. When a fire breaks out, which sequence of actions should be completed first under the muster list?
Your Answer: (Not answered)
Correct Answer: C (Raise the fire alarm, report to the bridge, muster as per the list and begin locating the fire and initial firefighting)
💡 On discovering a fire the alarm should first be raised and the bridge informed, then personnel mustered as per the muster list, the seat and extent of the fire located, initial firefighting begun with escape routes assured and ventilation closed. Raising the alarm has priority in all procedures and cannot follow mustering or informing the company.
✗
Question 32. What is the purpose of the automatic closing and hold-back release arrangements of fire doors?
Your Answer: (Not answered)
Correct Answer: D (To enable the doors to be held open for passage in normal service and to close automatically on a fire alarm to maintain the fire division)
💡 Under SOLAS II-2/9 fire doors required to be self-closing should be fitted with automatic closing arrangements and, where necessary, hold-back release arrangements that release the door on detection of a fire. The door may be held open in normal service for passage and ventilation and closes automatically on a fire alarm to maintain the fire division. The arrangements should be tested regularly.
✗
Question 33. What is required for liferafts to float free when the ship sinks?
Your Answer: (Not answered)
Correct Answer: C (Their stowage and securing must allow them to float free, unhindered by lashings or structure)
💡 SOLAS requires liferafts to be stowed and secured so that they can float free if the ship sinks, with the hydrostatic release unit and weak link correctly arranged. Additional lashings or structural obstruction would prevent the raft floating free, a serious deficiency.
✗
Question 34. Which account of the segregation of dangerous goods holds up?
Your Answer: (Not answered)
Correct Answer: A (keeping the goods apart as the IMDG Code requires, from other dangerous goods, from foodstuffs and from accommodation)
💡 Segregation pulls chemically unsuitable substances apart horizontally and vertically to the level the Code gives, so that a leak does not bring them into reaction, foul foodstuffs or reach accommodation; on the stowage plan that becomes the choice of hold and tier, the distance from heat and from living spaces, and the number each term - away from, separated from - calls for. It is not advice and two parties cannot agree it away: the levels already reckon the consequence of a leak, and an agreed change of position may only be made within what the level demands. One hold with two tiers commonly does not satisfy it, some combinations calling for a different hold or separation by a complete deck. The requirement belongs in the plan prepared before loading and is re-worked whenever the stow changes.
✗
Question 35. Before a towing operation, whether towing another vessel or being towed, what should be prepared in particular?
Your Answer: (Not answered)
Correct Answer: D (Check the strength and arrangement of the towline, define the towing force and means of communication, assess stability and manoeuvring safety and prepare contingency plans)
💡 Before a towing operation the strength and arrangement of the towline, including the emergency towline, should be checked, the towing force and speed determined, the manoeuvring and communication arrangements, including emergency signals, defined, the stability and manoeuvring safety of both vessels assessed and contingency plans for a towline failure prepared. A continuous lookout and communication should be maintained during the tow.
✗
Question 36. What do SOLAS and GMDSS procedures require when a ship receives a distress alert from another ship?
Your Answer: (Not answered)
Correct Answer: B (Acknowledge it under the procedures and take the appropriate action, relaying if necessary, without transmitting anything that would interfere with distress traffic)
💡 GMDSS procedures require a distress alert to be acknowledged under the procedures and appropriate action taken, such as relaying it, informing a coast station or proceeding to assist, while nothing unrelated is transmitted on the distress frequency to interfere with the traffic.
✗
Question 37. The auxiliary steering gear shall be capable of putting the rudder from 15° on one side to 15° on the other, at half speed, within:
Your Answer: (Not answered)
Correct Answer: A (60 seconds)
💡 SOLAS II-1/29: the auxiliary steering gear shall be capable of the 15°-to-15° rudder movement at half speed within 60 seconds.
✗
Question 38. Besides the manual, what documentation of the SMS must be kept on board?
Your Answer: (Not answered)
Correct Answer: A (The procedures, instructions and records relevant to the ship, accessible to the crew)
💡 ISM Code 5 requires the ship to carry the SMS documentation relevant to her, including procedures, instructions and records, accessible to the crew for reference and compliance.
✗
Question 39. A cargo declared as steel is in fact scrap liable to self-heat. What should the master do?
Your Answer: (Not answered)
Correct Answer: B (Require accurate cargo information from the shipper and take measures suited to the true nature; refuse to load if the information is false)
💡 SOLAS VI/1 and the IMSBC Code require the shipper to provide accurate cargo information. Where the nature of the cargo differs from the declaration, the master should require correction, including the group, self-heating properties and hazards, and refuse to load where accurate information cannot be obtained or the cargo is not suitable, avoiding danger from self-heating.
✗
Question 40. What segregation is required between dangerous goods and foodstuffs?
Your Answer: (Not answered)
Correct Answer: D (Toxic or contaminating dangerous goods must be segregated from foodstuffs as the IMDG Code requires, preventing contamination)
💡 The IMDG Code requires class 6 toxic substances and materials liable to contaminate foodstuffs to be segregated from food cargoes as prescribed, normally in different holds or separated by a complete bulkhead, preventing leakage from contaminating food and poisoning persons. Stowing them adjacent on the ground that the packages are sound does not comply.
✗
Question 41. What reporting is required if equipment fails within a VTS area?
Your Answer: (Not answered)
Correct Answer: A (Report the failure and the ship's movements to the VTS at once so traffic can be managed)
💡 A failure within a VTS area should be reported to the VTS promptly, enabling the traffic centre to warn and manage surrounding vessels. Concealing or delaying the report increases the risk of collision.
✗
Question 42. What capability must a bulk carrier have for loading sequence and strength verification under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (The ability to verify hull stresses and stability at each stage of the approved loading sequence)
💡 SOLAS requires bulk carriers to work to an approved loading or unloading sequence and to verify hull stresses and stability at each stage using the loading instrument, preventing structural damage from concentrated local loading.
✗
Question 43. What fire detection arrangement is required for category A machinery spaces?
Your Answer: (Not answered)
Correct Answer: A (A fixed fire detection and fire alarm system capable of detecting a fire and indicating its location)
💡 SOLAS II-2/7 requires a fixed fire detection and alarm system in category A machinery spaces, giving early detection and indicating the location on the bridge or at a control station.
✗
Question 44. What monitoring of moisture content is required for cargoes liable to liquefy?
Your Answer: (Not answered)
Correct Answer: B (Confirm the moisture content is below the transportable moisture limit before loading and guard against rain increasing it during loading)
💡 The IMSBC Code requires confirmation that the moisture content is below the TML before loading, normally from a certificate or test report, with attention during loading to rain, changes in the moisture of the cargo and water in the hold, preventing the content rising above the TML and liquefaction at sea.
✗
Question 45. What isolation is required between ballast and cargo hold piping?
Your Answer: (Not answered)
Correct Answer: D (The ballast system must not be connected to the cargo spaces, preventing contamination or cross-connection affecting stability)
💡 SOLAS and MARPOL require the piping between the ballast system and the cargo holds or cargo tanks to be effectively isolated, by isolating valves, blanks or separate piping, preventing ballast water and cargo from cross-connecting, which would contaminate the cargo, cause abnormal stability or lead to an illegal discharge.
✗
Question 46. What do SOLAS and the related conventions address regarding sewage treatment systems?
Your Answer: (Not answered)
Correct Answer: D (The plant must operate and discharge in accordance with the requirements, with attention to the risk of harmful gas)
💡 A sewage treatment plant must be operated and discharge in accordance with MARPOL, and attention paid to the harmful gases which may be produced in the process. The relevant spaces should be ventilated, entry restricted and testing carried out as prescribed to prevent poisoning.
✗
Question 47. A self-igniting light on a lifebuoy is found inoperative because its battery has failed. The finding is?
Your Answer: (Not answered)
Correct Answer: C (The lifebuoy has lost its night-marking capability, a life-saving equipment deficiency to be replaced)
💡 The self-igniting light is used at night to mark the position of a person overboard and is a key attachment of the lifebuoy. A failed battery makes the lifebuoy unidentifiable at night. This is a functional deficiency of life-saving equipment; the battery or light should be replaced so that it is always ready for use.
✗
Question 48. What does COLREG require regarding sound signals in areas of dense traffic?
Your Answer: (Not answered)
Correct Answer: A (Manoeuvring and warning signals must be given as prescribed, with light signals where appropriate)
💡 COLREG requires vessels in sight of one another to give the prescribed manoeuvring signals, such as one short blast for a starboard alteration, and to sound warning signals in narrow channels or at a bend. Sound signals are an important means of indicating intention and warning others.
✗
Question 49. The self-contained breathing apparatus in a firefighter's outfit shall be capable of being used for at least:
Your Answer: (Not answered)
Correct Answer: C (30 minutes)
💡 SOLAS II-2/10: the self-contained breathing apparatus in a firefighter's outfit shall be capable of being used for at least 30 minutes.
✗
Question 50. Regarding ventilation of cargo tank areas on a tanker:
Your Answer: (Not answered)
Correct Answer: D (adequate ventilation shall be provided with inlets and outlets arranged to prevent accumulation of vapour)
💡 SOLAS II-2/4 requires adequate ventilation arranged to prevent accumulation of vapour.
✗
Question 51. What is required for the frequency of position checks?
Your Answer: (Not answered)
Correct Answer: A (Determined by the trading area and navigational conditions, with more frequent checks in confined waters)
💡 The frequency of position checks should be determined by the risks of the area and the navigational conditions: longer intervals may be acceptable in open waters, while in confined waters, coastal passages and when entering port checks should be more frequent, such as at short intervals or at every alteration, ensuring deviations and dangers are detected in time.
✗
Question 52. What is the purpose of a loading instrument on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Computing hull strength and stability at each stage of loading)
💡 Computing hull strength and stability at each stage of loading and discharging.
✗
Question 53. Which of the following is NOT part of an abandon ship drill under SOLAS III/19?
Your Answer: (Not answered)
Correct Answer: C (Checking crew wage and leave records)
💡 SOLAS III/19 lists summoning of persons, checking dress and lifejackets, briefing and operation of launching appliances and checking equipment readiness. Wage and leave records are not part of a drill.
✗
Question 54. What is the requirement for rescue boats on cargo ships?
Your Answer: (Not answered)
Correct Answer: D (At least one rescue boat)
💡 At least one rescue boat shall be provided.
✗
Question 55. A high-temperature exhaust pipe in the engine room is found without thermal insulation. The finding is?
Your Answer: (Not answered)
Correct Answer: D (Hot surfaces should be insulated to prevent ignition of combustibles; absence is a fire protection deficiency)
💡 Surfaces in a machinery space whose temperature could ignite combustibles or scald personnel, such as exhaust and steam pipes, should be insulated or otherwise protected as required. Unprotected they can become an ignition source when fuel or oil mist leaks. It is a fire protection deficiency to be corrected.
✗
Question 56. What should be checked on hatch covers before loading a bulk carrier?
Your Answer: (Not answered)
Correct Answer: C (That the seals, cleats and drain channels are sound, with a hose test to verify watertightness if necessary)
💡 Before loading, the hatch cover seals should be checked for ageing or damage, the cleats for completeness and effectiveness and the drain channels and non-return devices for clearance, with a hose test to verify watertightness where necessary. Hatch cover failure is the principal cause of flooding in bulk carriers.
✗
Question 57. What does SOLAS III/19 require regarding lifeboats in abandon ship drills?
Your Answer: (Not answered)
Correct Answer: A (At least once every three months the boat is to be launched, and where reasonable and practicable lowered to the water and manoeuvred)
💡 SOLAS III/19 requires launching drills at least every three months, with the boat, where reasonable and practicable, lowered into the water and manoeuvred at least once in that period.
✗
Question 58. What electrical equipment is required in a pump room on a tanker?
Your Answer: (Not answered)
Correct Answer: B (Explosion-protected equipment, with the number of items and wiring minimised)
💡 A pump room is a high-risk space where hydrocarbon vapour can accumulate. SOLAS and the IBC Code require explosion-protected equipment with the number of items and wiring kept to a minimum, preventing electrical sparks from igniting vapour.
✗
Question 59. During a PSC inspection the firefighter's outfits were checked. Under SOLAS II-2/10.1, which of the following is NOT part of a firefighter's outfit?
Your Answer: (Not answered)
Correct Answer: D (A portable gas detector)
💡 SOLAS II-2/10.1 defines a firefighter's outfit as personal equipment (protective clothing, boots and gloves, rigid helmet, electric safety lamp and axe) together with a self-contained compressed air breathing apparatus. A gas detector belongs to other requirements such as enclosed space entry and is not part of the outfit.
✗
Question 60. In which spaces must ceilings and linings be of non-combustible material?
Your Answer: (Not answered)
Correct Answer: A (In enclosures of stairways and corridors forming escape routes)
💡 SOLAS requires non-combustible linings and ceilings in critical spaces such as stairway enclosures and corridors serving as escape routes, limiting the spread of fire and keeping the escape route safe.
✗
Question 61. What is the relationship between a lifeboat's permitted complement and the overload test?
Your Answer: (Not answered)
Correct Answer: B (The boat should be used within its permitted complement, with an overload test carried out as required to verify strength and safety)
💡 A lifeboat's permitted complement is the specified safe carrying capacity and must not be exceeded in use. Under the relevant requirements a lifeboat may undergo an overload test, such as at one point one times the permitted complement or a specified load, to verify the strength and safety margin of the davits and the boat. Overloading endangers the safety of launching.
✗
Question 62. What does SOLAS address regarding zoning of fire detection systems?
Your Answer: (Not answered)
Correct Answer: C (The system must identify the section in which the alarm originated, enabling the fire to be located quickly)
💡 SOLAS requires fixed fire detection systems to be arranged in sections so that the alarm indicates the section or space in which it originated, enabling the watchkeeper to confirm the actual location and act quickly.
✗
Question 63. The Continuous Synopsis Record (CSR) is intended to:
Your Answer: (Not answered)
Correct Answer: C (record the history and major events of the ship such as changes of name, owner and class)
💡 SOLAS XI-1/3: the Continuous Synopsis Record records the history and major events of the ship such as changes of name, owner and class.
✗
Question 64. What must be done before a 406 MHz satellite EPIRB is brought into service?
Your Answer: (Not answered)
Correct Answer: C (Registered with the relevant authority with up-to-date information)
💡 406 MHz EPIRBs shall be registered with current information so that alerts can be verified and rescue coordinated.
✗
Question 65. What is the main purpose of establishing restricted areas under the ship security plan?
Your Answer: (Not answered)
Correct Answer: C (To prevent unauthorised access and the introduction of weapons or dangerous articles)
💡 ISPS Code Part A/10 requires restricted areas to be identified and controlled in order to prevent unauthorised access and the introduction of weapons or dangerous articles on board. Convenience of operations is not the purpose.
✗
Question 66. On what document shall the stowage and securing of cargo units and vehicles be based?
Your Answer: (Not answered)
Correct Answer: B (A Cargo Securing Manual approved by the Administration)
💡 SOLAS VI: an approved Cargo Securing Manual shall be carried and followed.
✗
Question 67. What is required for monitoring stability during loading and unloading?
Your Answer: (Not answered)
Correct Answer: C (Monitor stability and strength at each stage against the loading plan, preventing excessive hogging or sagging or insufficient initial stability)
💡 SOLAS requires stability and hull strength to be monitored at each stage against the loading plan, preventing excessive hogging or sagging and insufficient initial stability. Calculating only afterwards cannot prevent structural damage during cargo work.
✗
Question 68. A free-fall lifeboat shall be capable of being launched safely:
Your Answer: (Not answered)
Correct Answer: C (within the specified range of trim and list)
💡 SOLAS III/16 requires a free-fall lifeboat to launch safely within the specified trim and list range.
✗
Question 69. A watertight door is found unable to be closed remotely from the bridge. The finding is?
Your Answer: (Not answered)
Correct Answer: A (Watertight doors must be remotely closable with indication of their open or closed position; failure affects subdivision integrity)
💡 Where subdivision requires it a watertight door, especially a remotely controlled one, must be capable of remote closure from the central control station on the bridge with position indication there. Loss of remote control affects the ability to close doors rapidly and maintain subdivision integrity in the event of flooding. It is a deficiency to be corrected.
✗
Question 70. A radar transponder (SART) shall operate in the frequency band:
Your Answer: (Not answered)
Correct Answer: D (9 GHz (X-band))
💡 SOLAS IV/7: a SART operates in the 9 GHz (X-band) band so that it can be displayed on a ship's radar.
✗
Question 71. On what basis is the extent of close-up survey determined?
Your Answer: (Not answered)
Correct Answer: A (Ship type, age, cargo characteristics and known high risk areas taken together)
💡 The ESP requires the extent of close-up survey to be determined by the ship type and age, the characteristics of the cargoes carried, such as the corrosive or abrasive effect of coal and ore, and the known high risk areas such as hatch coamings and hopper tanks, supported by a survey programme.
✗
Question 72. The gas regulating valve in a tanker inert gas system is used to:
Your Answer: (Not answered)
Correct Answer: C (regulate the flow of inert gas into cargo tanks and prevent backflow)
💡 SOLAS II-2/5 requires a gas regulating valve to control inert gas flow into cargo tanks and prevent backflow.
✗
Question 73. A portable gas detector is found beyond its calibration validity. The finding is?
Your Answer: (Not answered)
Correct Answer: C (An uncalibrated detector gives untrustworthy readings, a deficiency affecting enclosed space safety)
💡 A portable gas detector is essential for judging whether the atmosphere is safe before entering an enclosed space or carrying out hot work. Beyond its calibration validity its readings cannot be trusted and may lead to a wrong judgement that endangers personnel. It is a deficiency to be corrected.
✗
Question 74. What is a typical measure for controlling heel in the damage control information?
Your Answer: (Not answered)
Correct Answer: A (Counter-flooding the opposite side to reduce the heel and restore some stability and floating position)
💡 Measures for controlling heel include counter-flooding the side opposite the damaged compartment, reducing the heel, lifting the opening clear of the water or restoring some stability. The plan should follow the damage control information and booklet after calculation; blind action makes matters worse.
✗
Question 75. What is the basic requirement of a proper look-out during a navigational watch?
Your Answer: (Not answered)
Correct Answer: A (Maintain look-out by sight and hearing as well as by all available means, with the look-out not impeded by other duties)
💡 COLREG and SOLAS require a look-out at all times by sight, hearing and all available means, making a full appraisal of the situation and risk of collision. The look-out must not be given duties that interfere with the watch.
✗
Question 76. Before hot work in the cargo tank area of a tanker, what must be done under SOLAS and related guidance?
Your Answer: (Not answered)
Correct Answer: D (Gas testing, a hot work permit, removal of combustibles and firefighting standby precautions)
💡 SOLAS and ISGOTT require gas testing, removal of combustible material, a hot work permit and firefighting standby before hot work in a tanker's cargo area. None of these steps may be omitted.
✗
Question 77. What is the first action if dangerous goods catch fire on board?
Your Answer: (Not answered)
Correct Answer: D (Raise the alarm, establish the nature of the cargo from the EmS Guide and select the appropriate extinguishing medium, with protection of personnel)
💡 A dangerous goods fire requires the alarm to be raised at once and the nature of the cargo established from the EmS Guide, with the extinguishing medium selected accordingly, since some cargoes react with water or liberate toxic gas and water is prohibited. Personnel must be protected and evacuated, and blind use of water or a close approach avoided.
✗
Question 78. What should be done after a water ingress alarm on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (Identify the flooded hold, assess the effect on stability and strength and take measures such as pumping or adjustment, reporting as required)
💡 On a water ingress alarm the flooded hold and the cause should be established at once, such as hatch leakage, hull damage or piping leakage, the effect on stability, strength and draught assessed and measures taken such as pumping, adjusting ballast or reducing cargo, with the company and the Administration informed under the SMS.
✗
Question 79. What does SOLAS require for air pipes and sounding pipes passing through watertight bulkheads?
Your Answer: (Not answered)
Correct Answer: A (Reliable means of closing and sealing must be provided to maintain watertight integrity)
💡 SOLAS requires reliable closing and sealing arrangements for air and sounding pipes crossing watertight bulkheads, maintaining watertight integrity. Open ends or a deck cap alone are not sufficient.
✗
Question 80. What oxygen level is normally required before entering an enclosed space?
Your Answer: (Not answered)
Correct Answer: B (Between 19.5 and 23 per cent by volume)
💡 The oxygen content in an enclosed space should be between 19.5 and 23 per cent before entry. Below 19.5 per cent there is a risk of asphyxiation; above 23 per cent the risk of combustion and explosion increases. Both departures are unsafe.
✗
Question 81. Cargo ships shall be provided with survival craft having a capacity for:
Your Answer: (Not answered)
Correct Answer: D (100% of the total number of persons on board)
💡 SOLAS III/31 requires cargo ships to be provided with survival craft for 100% of the total number of persons on board.
✗
Question 82. How must the loading instrument of a bulk carrier be used?
Your Answer: (Not answered)
Correct Answer: B (Compute strength and stability for the planned sequence before cargo work and monitor continuously during it)
💡 SOLAS requires the approved loading instrument to be used to compute hull strength and stability at each stage of the planned sequence before cargo work, with continuous monitoring during the operation and updating as it progresses, preventing excessive stress at any stage. Computing only at the end cannot prevent damage during the work.
✗
Question 83. Which material is prohibited for bulkheads on board?
Your Answer: (Not answered)
Correct Answer: B (Combustible material (other than as provided))
💡 Combustible materials are restricted; non-combustible material shall generally be used.
✗
Question 84. Lifeboat launching drills shall be conducted:
Your Answer: (Not answered)
Correct Answer: B (under sailing conditions as well, to train the crew in emergency operations)
💡 SOLAS III/19: lifeboat launching drills shall be conducted under sailing conditions as well, so as to train the crew in actual operation.
✗
Question 85. What does SOLAS require for side scuttles in the shell below the freeboard deck?
Your Answer: (Not answered)
Correct Answer: D (Effective hinged closing appliances capable of maintaining watertightness at sea)
💡 SOLAS II-1/16 requires side scuttles below the freeboard deck to have effective hinged watertight closing appliances capable of maintaining watertightness at sea. Fixed windows or improvised timber blanking do not comply.
✗
Question 86. A ship carrying bulk grain must satisfy which stability requirement?
Your Answer: (Not answered)
Correct Answer: C (The stability requirements of the International Grain Code)
💡 SOLAS VI/8: bulk grain carriers must comply with the International Grain Code stability requirements.
✗
Question 87. What is required of the torch carried in survival craft?
Your Answer: (Not answered)
Correct Answer: D (It must be watertight and capable of continuous illumination, provided in the craft for use at night)
💡 SOLAS requires survival craft to carry a watertight torch, normally one per boat or as prescribed, providing light at night after abandonment for checking the condition of the craft, signalling or assisting a person. An ordinary torch is not waterproof and would fail at sea.
✗
Question 88. The inert gas system shall keep the oxygen content in cargo tanks below:
Your Answer: (Not answered)
Correct Answer: A (8%)
💡 Below 8% by volume.
✗
Question 89. Which ships shall be fitted with a VDR?
Your Answer: (Not answered)
Correct Answer: A (Passenger ships and cargo ships of 3000 GT and above)
💡 Passenger ships and cargo ships of 3000 GT and above.
✗
Question 90. What is the officer of the watch's responsibility after a pilot boards?
Your Answer: (Not answered)
Correct Answer: D (Continue to assist the pilot with look-out, position monitoring and checking the execution of engine and rudder orders; the pilot's presence does not relieve the master or officers)
💡 A pilot provides local advice but does not bear responsibility for the safety of the ship. The officer of the watch must continue to assist with the look-out, check the position and monitor the execution of engine and rudder orders. The duty of the watch must never be abandoned.
✗
Question 91. What does SOLAS and the related rules address regarding cargo ventilation?
Your Answer: (Not answered)
Correct Answer: B (Ventilating appropriately according to the nature of the cargo, preventing self-heating, harmful gas accumulation or condensation damage)
💡 SOLAS and the IMSBC Code require the method and timing of ventilation to suit the cargo: some need ventilation to remove heat, others must not be ventilated to avoid moisture uptake or increased self-heating. Ventilating blindly may make matters worse.
✗
Question 92. Where must the muster list be posted?
Your Answer: (Not answered)
Correct Answer: A (On the bridge and in the spaces where emergency duties are assigned)
💡 The muster list is posted on the bridge and at each station where emergency duties are performed.
✗
Question 93. When an oil pollution incident occurs at sea, besides taking control and clean-up measures, what should be done?
Your Answer: (Not answered)
Correct Answer: B (Report to the Administration and those concerned under the Shipboard Oil Pollution Emergency Plan and record the incident and cooperate with the clean-up)
💡 When an oil pollution incident occurs, control, clean-up and reporting measures should be taken under the Shipboard Oil Pollution Emergency Plan, the incident reported to the flag State, coastal State and those concerned, records kept and the authorities' clean-up and investigation cooperated with. Concealing or delaying a report aggravates liability and hinders response.
✗
Question 94. What must the PWOM contain regarding operational measures for polar waters?
Your Answer: (Not answered)
Correct Answer: A (Ice assessment in voyage planning, ship capability limitations, emergency procedures and training requirements)
💡 The Polar Water Operational Manual must cover voyage planning, ice assessment, the ship's ice class capabilities and limitations, operation of equipment in low temperature, emergency procedures and training, guiding the master's decisions in ice.
✗
Question 95. What is the master's duty when an incident involves dangerous goods?
Your Answer: (Not answered)
Correct Answer: A (Report to the authorities and take emergency measures)
💡 Report to the authorities and take the appropriate emergency measures.
✗
Question 96. A Passenger Ship Safety Certificate shall be issued for a period not exceeding:
Your Answer: (Not answered)
Correct Answer: D (12 months)
💡 SOLAS I/12: a Passenger Ship Safety Certificate shall be issued for a period not exceeding 12 months.
✗
Question 97. What is required in responding to a chemical cargo leak on a chemical tanker?
Your Answer: (Not answered)
Correct Answer: A (Follow the measures in the cargo emergency schedule (EmS), including protection, containment, collection and neutralisation, not using water indiscriminately)
💡 A chemical leak requires the measures in the EmS and the safety data sheet to be followed, since chemicals react differently with water, some generating heat or toxic gas. Using water without regard to the chemical may make the situation worse.
✗
Question 98. What is required regarding the order of abandonment when passengers are on board?
Your Answer: (Not answered)
Correct Answer: B (Passengers organised to leave first under the prepared procedure, with crew guiding, assisting boarding and handling the craft, the master leaving last)
💡 SOLAS requires passengers to be evacuated first in an orderly way under the prepared procedure on a passenger ship, with the crew guiding, assisting with boarding and handling the craft and the master leaving last. The crew leaving first or disorder would cause heavy casualties.
✗
Question 99. What maintenance is required for steering gear hydraulic oil and filters?
Your Answer: (Not answered)
Correct Answer: B (Oil quality checked, filters and oil changed as the manufacturer requires, with maintenance recorded)
💡 The hydraulic steering gear should have its oil quality checked periodically, including water, contamination and viscosity changes, with filters and oil changed as the maker requires and the maintenance recorded. Deteriorated oil causes valves to stick and steering to fail, so this is preventive maintenance of essential equipment.
✗
Question 100. What is the recommended action if a ship develops a list while under way?
Your Answer: (Not answered)
Correct Answer: B (Establish the cause, such as cargo shift, flooding or uneven ballast, and correct it promptly to prevent increasing list)
💡 An abnormal list at sea requires the cause to be established and corrective action taken, such as adjusting ballast or checking for flooding in a hold. A list of unknown cause or increasing may be the precursor of cargo shift or flooding, and ignoring it endangers the ship.