Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. What are the security measures at security level 1?
Your Answer: (Not answered)
Correct Answer: B (The minimum protective measures maintained at all times in normal conditions, such as controlling access and monitoring restricted areas)
💡 ISPS Code Part A/12 requires security level 1 to be maintained continuously, including control of access to the ship, monitoring of restricted areas and supervision of persons and cargo embarking. These are the basic measures in normal operation.
✗
Question 2. Before the ship proceeds to sea, the voyage plan shall be prepared by:
Your Answer: (Not answered)
Correct Answer: B (the master)
💡 SOLAS V/34: the voyage plan shall be prepared before departure by the master.
✗
Question 3. What is the stability concern when carrying grain in bulk?
Your Answer: (Not answered)
Correct Answer: B (Heeling moments from grain settling and shifting cause a list, assessed under the International Grain Code)
💡 Grain in bulk settles and shifts as the ship rolls, producing heeling moments and a persistent list. The International Grain Code requires stability to be assessed using assumed heeling moments from grain shift, with the resulting angle of heel limited to a prescribed value, normally 12 degrees.
✗
Question 4. At what angle of list must lifeboat launching appliances still operate?
Your Answer: (Not answered)
Correct Answer: A (A list of up to 20 degrees to either side)
💡 SOLAS requires launching appliances to be capable of operation with the ship listed up to 20 degrees either way. Free-fall lifeboats have additional conditions such as trim by the stern.
✗
Question 5. What should be noted about steering gear in cold climates?
Your Answer: (Not answered)
Correct Answer: C (The increased oil viscosity and the effect of low temperature on pipes must be considered, with heating or low temperature oil as necessary)
💡 In cold climates the increased viscosity of the hydraulic oil slows the steering response and increases pressure loss in the piping. Oil suited to low temperature should be used as the maker requires, with heating where necessary, and the steering gear fully tested before sailing, preventing loss of steering in confined waters.
✗
Question 6. The ISPS Code applies to:
Your Answer: (Not answered)
Correct Answer: A (passenger ships and cargo ships of 500 GT and above engaged on international voyages)
💡 SOLAS XI-2/3: the ISPS Code applies to passenger ships and cargo ships of 500 GT and above engaged on international voyages.
✗
Question 7. Survival craft drills shall be conducted at what minimum frequency?
Your Answer: (Not answered)
Correct Answer: D (at least once a month)
💡 SOLAS III/19 requires abandon-ship and fire drills at least monthly.
✗
Question 8. What is the position under SOLAS V and the related rules regarding responsibility when a pilot is on board?
Your Answer: (Not answered)
Correct Answer: B (The pilot advises; the master retains full responsibility for the safety of the ship)
💡 A pilot contributes local knowledge and handling expertise but commands no authority over the ship; the master retains overall responsibility and command for her safety.
✗
Question 9. What is the purpose of the emergency source of electrical power?
Your Answer: (Not answered)
Correct Answer: A (To supply essential services such as emergency lighting, communications and steering when the main source fails)
💡 The emergency source supplies essential safety services when the main source fails, maintaining lighting, communication and steering capability. It is not intended to replace the main source for extended operation.
✗
Question 10. What marking shall survival craft have for night detection?
Your Answer: (Not answered)
Correct Answer: D (Lighting or retro-reflective material to aid detection)
💡 Lighting or retro-reflective material to aid detection.
✗
Question 11. What is required for backup power of the firefighting system?
Your Answer: (Not answered)
Correct Answer: C (The emergency fire pump must have a source of power independent of the main fire pumps, so water is available on a blackout or machinery space fire)
💡 SOLAS requires the emergency fire pump to be independently driven, such as by a dedicated diesel engine or an independent power supply, so that it can still supply water if a blackout or a fire in the machinery space puts the main fire pumps out of action. It is essential to the redundancy of the firefighting system.
✗
Question 12. Sea area A3 means an area, excluding sea areas A1 and A2, within the coverage of:
Your Answer: (Not answered)
Correct Answer: C (an Inmarsat geostationary satellite service)
💡 SOLAS IV/2: Sea area A3 is the area, excluding A1 and A2, within the coverage of an Inmarsat geostationary satellite service.
✗
Question 13. What overload protection is required for electrical equipment?
Your Answer: (Not answered)
Correct Answer: C (Overload protection for essential motors and cables, preventing overheating which damages insulation and causes fire)
💡 SOLAS requires overload protection for essential motors, cables and distribution equipment, operating to trip or alarm on overload, preventing prolonged overheating from ageing the insulation and causing an electrical fire, particularly in the high temperature environment of a machinery space.
✗
Question 14. For a cargo ship, the pressure at any hydrant below the maximum breadth shall be not less than:
Your Answer: (Not answered)
Correct Answer: A (0.2 N/mm² (2 bar))
💡 SOLAS II-2/10 requires a pressure of not less than 0.2 N/mm² (2 bar) at any hydrant below the maximum breadth of a cargo ship.
✗
Question 15. What is the usual maximum validity of a Cargo Ship Safety Radio Certificate?
Your Answer: (Not answered)
Correct Answer: B (Five years, with periodical surveys)
💡 Under SOLAS I/12 the Cargo Ship Safety Radio Certificate has a usual validity of not more than five years, with periodical surveys as required. The performance and provision of the radio installation, including distress alerting, communications and the reserve source of energy, are the focus of the survey.
✗
Question 16. A paint locker shall be located behind:
Your Answer: (Not answered)
Correct Answer: B (A class divisions, with independent ventilation and extinguishing arrangements)
💡 SOLAS II-2/9 requires paint lockers to be bounded by A class divisions with independent ventilation and extinguishing.
✗
Question 17. What is the required interval for emergency steering drills?
Your Answer: (Not answered)
Correct Answer: C (At least once every three months)
💡 Under SOLAS III/19 emergency steering drills should be held at least once every three months. The drill makes the crew familiar with the procedures and communications for changing to the emergency steering gear when the main steering fails, and is a key emergency preparedness item.
✗
Question 18. A radar transponder (SART) shall operate in the frequency band:
Your Answer: (Not answered)
Correct Answer: D (9 GHz (X-band))
💡 SOLAS IV/7: a SART operates in the 9 GHz (X-band) band so that it can be displayed on a ship's radar.
✗
Question 19. What are the handling requirements when encountering heavy swell and seas?
Your Answer: (Not answered)
Correct Answer: A (Adjust course and speed so that the hull meets the seas at a suitable angle, avoiding a beam sea and direct head seas which cause damage)
💡 In heavy seas and swell the course and speed should be adjusted so the hull meets the seas at a suitable angle, normally obliquely, avoiding a beam sea which causes heavy rolling and cargo shift and direct head seas which cause violent pitching and slamming that damages the hull.
✗
Question 20. The ship security alert system (SSAS) fails its test and cannot transmit an alert to the Administration. The finding is?
Your Answer: (Not answered)
Correct Answer: B (SSAS failure affects the ability to call for help when attacked, a security equipment deficiency to be corrected)
💡 The ship security alert system should be able to transmit an alert to the shore receiving point designated by the Administration when the ship is under a security threat and should be available at all times. A failed test shows it cannot fulfil its function at the critical moment. It is a security equipment deficiency to be corrected.
✗
Question 21. If more than the specified proportion of the crew of a cargo ship is changed, when should abandon-ship and fire drills be held?
Your Answer: (Not answered)
Correct Answer: C (Within 24 hours after leaving port if more than 25 per cent of the crew has changed)
💡 Under SOLAS III/19, if more than twenty-five per cent of the crew has been changed, abandon-ship and fire drills should be held within twenty-four hours after the ship leaves port. This ensures that newly joined crew quickly become familiar with their emergency duties without waiting for the routine monthly drill.
✗
Question 22. Each ship shall carry at least how many sets of firefighter's outfits?
Your Answer: (Not answered)
Correct Answer: C (2)
💡 SOLAS II-2/10: each ship shall carry at least two sets of firefighter's outfits.
✗
Question 23. In SOLAS I/2 the expression "upright position" is used to define which condition of the ship?
Your Answer: (Not answered)
Correct Answer: B (The reference condition with no heel, used for measuring freeboard and similar particulars)
💡 SOLAS and the Load Line Convention take the upright (no heel) condition as the datum for measuring moulded depth, freeboard and similar particulars, irrespective of the loading condition.
✗
Question 24. A PSC inspection found the radio maintenance arrangements unclear. Which of the following is NOT an acceptable option under SOLAS IV/15?
Your Answer: (Not answered)
Correct Answer: D (Relying on the crew's experience at sea with no training or spare parts support)
💡 SOLAS IV/15 allows availability to be assured by duplication of equipment, a shore-based maintenance agreement, or at-sea maintenance capability with trained personnel, spares and test equipment. Experience-based repair without training or spares is not an acceptable arrangement.
✗
Question 25. What does SOLAS II-2 require regarding combustible materials in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: B (Surface materials and furnishings must be restricted in combustibility and comply with prescribed flame spread requirements)
💡 SOLAS II-2 limits the combustibility of bulkheads, ceilings, deck coverings and furniture in accommodation spaces, reducing fire load and the rate of spread.
✗
Question 26. What is the function of a thermal protective aid?
Your Answer: (Not answered)
Correct Answer: D (To reduce loss of body heat in a survival craft and prevent hypothermia)
💡 A thermal protective aid is used to wrap a person and reduce loss of body heat in a survival craft, preventing hypothermia. It has no buoyancy and is not used to immobilise casualties.
✗
Question 27. From what tonnage shall speed and distance measuring equipment be fitted?
Your Answer: (Not answered)
Correct Answer: B (500 GT)
💡 500 GT and above.
✗
Question 28. Subdivision and damage stability keep a passenger ship afloat after damage. What is the basic assumption of the flooding calculation under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (Flooding of an assumed group of adjacent compartments is considered)
💡 SOLAS requires the flooding calculation to consider an assumed extent of damage affecting a group of adjacent compartments, verifying the ship's survivability in that condition. It is neither single-compartment damage nor flooding of the whole ship.
✗
Question 29. How should the master deal with a cargo liable to liquefy whose moisture content exceeds the transportable moisture limit?
Your Answer: (Not answered)
Correct Answer: D (Refuse to load, or take measures permitted by the Code such as re-consigning or trimming and drainage before loading)
💡 The IMSBC Code recognises that a cargo liable to liquefy with moisture above the TML may liquefy at sea and capsize the ship. The master must refuse to load or take approved measures to bring the cargo within limits, never load on the chance it will be all right.
✗
Question 30. What may follow if a port State inspection finds a deficiency seriously affecting safety?
Your Answer: (Not answered)
Correct Answer: A (The ship may be detained until the deficiency is rectified and the flag State and recognised organisation notified)
💡 Under PSC procedures, where a deficiency seriously endangers the ship, persons or the environment, the port State may detain the ship until it is rectified, normally notifying the flag State and recognised organisation. A deadline or a record alone is not enough for a serious deficiency.
✗
Question 31. What is one of the core objectives of the safety management system under the ISM Code?
Your Answer: (Not answered)
Correct Answer: B (Preventing human injury or loss of life, pollution and damage to property, with continuous improvement of safety management)
💡 ISM Code 1 sets out the objectives of ensuring safety at sea, prevention of human injury or loss of life and avoidance of damage to the environment and to property, with continuous improvement of safety management as the means. Commercial performance is not among the objectives.
✗
Question 32. A portable fire extinguisher is found without its securing bracket and may topple and be damaged in rough weather. The finding is?
Your Answer: (Not answered)
Correct Answer: C (Extinguishers should be properly secured and readily available; failure to secure is a deficiency to be corrected)
💡 A portable fire extinguisher should be secured in its designated position so that it is readily available and does not topple, collide and be damaged or cause injury as the ship rolls. Failure to secure it affects both availability and the risk of damage. It is a deficiency to be corrected.
✗
Question 33. What does SOLAS address regarding the protective clothing of a firefighter's outfit?
Your Answer: (Not answered)
Correct Answer: B (It must protect the skin from flame and heat radiation without impeding the wearer's movement)
💡 SOLAS requires the protective clothing of a firefighter's outfit to protect the skin from harm by flame and heat radiation, with an outer surface that is water resistant, and of a size that allows the wearer to move freely.
✗
Question 34. What shall a B-class division satisfy?
Your Answer: (Not answered)
Correct Answer: D (Prevent passage of flame for a stated time and of smoke)
💡 B-class divisions prevent passage of flame for the stated time and of smoke.
✗
Question 35. The double bottom shall be fitted:
Your Answer: (Not answered)
Correct Answer: B (extending from the collision bulkhead to the afterpeak bulkhead)
💡 SOLAS II-1/9 requires the double bottom generally to extend from the collision bulkhead to the afterpeak bulkhead.
✗
Question 36. What does SOLAS and the Polar Code require regarding manning and training for polar waters?
Your Answer: (Not answered)
Correct Answer: A (The master and officers in charge of a navigational watch must have completed appropriate polar waters training and gained the required experience)
💡 SOLAS XIV and STCW require the master and officers in charge of a navigational watch of a ship in polar waters to have completed polar waters training appropriate to the ship's category and to have the prescribed seagoing experience, ensuring the ability to operate in polar conditions.
✗
Question 37. What is the minimum number of radar transponders (SARTs) for a cargo ship of 500 gross tonnage and above?
Your Answer: (Not answered)
Correct Answer: D (Two, one on each side)
💡 Under SOLAS IV/7 a cargo ship of five hundred gross tonnage and above should carry at least two radar transponders, normally one on each side, so that one can be taken into the survival craft on either side during abandonment. The SART marks the distress position on the radar.
✗
Question 38. Which types of emergency source of power does SOLAS permit?
Your Answer: (Not answered)
Correct Answer: A (An emergency generator or a battery, supplying the emergency services for the prescribed period)
💡 SOLAS permits the emergency source to be an emergency generator or a battery. Where a battery is used its capacity must carry the emergency services, such as emergency lighting, communications and alarms, for the prescribed period.
✗
Question 39. Which fixed fire-extinguishing system shall be provided for the cargo tank deck area of a tanker?
Your Answer: (Not answered)
Correct Answer: A (Deck foam system)
💡 SOLAS II-2/10.5: tankers shall be fitted with a fixed deck foam system for the cargo tank deck area.
✗
Question 40. How does a non-conformity differ from an accident under the system?
Your Answer: (Not answered)
Correct Answer: D (a non-conformity being a state in which a requirement is not met, an accident an event that has caused injury, loss or pollution, and both, with near misses, to be reported and looked into)
💡 The non-conformity says a requirement has not been met: an entry missing from the record book, a drill or a course not done as planned, a survey overdue, the procedure on paper and another way on board, an observation from the last audit left unclosed. None of these has yet harmed anyone and all of them call for correction. The accident is named by what it did - injury, loss or pollution has in fact happened. Both are to be reported, looked into for cause and corrected, and the inquiry is meant to end at the management system rather than at the statement that a man handled it badly, which is also why the hazardous occurrence is listed by itself: the close run that did no harm is precisely the accident that has not yet happened. Downgrading whatever did no damage to a non-conformity, or holding that a departure in how work is done is not one either, takes the edge off the statistics and leaves the review with nothing to decide on.
✗
Question 41. Which of the following are statutory certificates of a cargo ship under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (The Cargo Ship Safety Construction Certificate, the Cargo Ship Safety Equipment Certificate and the Cargo Ship Safety Radio Certificate)
💡 Under SOLAS I/7 and I/12 the statutory certificates of a cargo ship mainly include the Cargo Ship Safety Construction Certificate, the Cargo Ship Safety Equipment Certificate and the Cargo Ship Safety Radio Certificate, or a combined Cargo Ship Safety Certificate, as well as the International Load Line Certificate and the Safety Management Certificate. A certificate of competency belongs to the STCW, and insurance policies and receipts are not statutory certificates.
✗
Question 42. In the event of an incident involving dangerous goods, the ship shall:
Your Answer: (Not answered)
Correct Answer: D (report in accordance with the IMDG Code procedures and take emergency measures)
💡 SOLAS VII/4 requires reporting in accordance with IMDG Code procedures and emergency measures.
✗
Question 43. Where must the muster list be posted?
Your Answer: (Not answered)
Correct Answer: A (On the bridge and in the spaces where emergency duties are assigned)
💡 The muster list is posted on the bridge and at each station where emergency duties are performed.
✗
Question 44. What is required for pilot transfer arrangements?
Your Answer: (Not answered)
Correct Answer: D (Comply with the SOLAS safety requirements and be inspected regularly)
💡 They shall comply with SOLAS safety requirements and be regularly inspected.
✗
Question 45. What should be noted about using survival craft at low temperature in polar waters?
Your Answer: (Not answered)
Correct Answer: B (Difficulty in starting engines, reduced battery capacity and changed equipment performance, with insulation and pre-heating measures taken)
💡 Using survival craft in polar conditions requires attention to difficulty in starting engines, addressed by insulation, pre-heating and oil suited to low temperature, reduced battery capacity, addressed by insulation or spares, changed performance of equipment and the risk of hypothermia, with plans and drills in place.
✗
Question 46. When is the safety signal SECURITE used?
Your Answer: (Not answered)
Correct Answer: C (To broadcast navigational safety information such as a floating hazard or a gale warning)
💡 SECURITE is the safety signal, used to broadcast navigational safety information such as a hazard, a weather warning or a navigational warning. Its priority is lower than MAYDAY and PAN PAN but it is still safety traffic, and unrelated calls must not occupy the frequency.
✗
Question 47. What does SOLAS XII require regarding the sequence of loading or unloading bulk carriers?
Your Answer: (Not answered)
Correct Answer: A (An approved sequence complying with structural strength limitations must be used)
💡 SOLAS XII requires loading and unloading to follow an approved sequence within structural limits. Skipping holds or working for speed alone can overstress the hull.
✗
Question 48. What attention must be paid to crew mental health and fatigue?
Your Answer: (Not answered)
Correct Answer: C (Attention to the effect of mental state and fatigue on safety, mitigated by sensible work and rest arrangements and communication)
💡 The MLC and STCW require attention to the mental health and fatigue of the crew, addressed by sensible arrangement of work and rest, maintained lines of communication and support and improved living conditions. Fatigue and mental stress affect judgement and performance and are major contributors to accidents.
✗
Question 49. What does SOLAS address regarding fixed fire detection in ro-ro spaces?
Your Answer: (Not answered)
Correct Answer: B (A fixed fire detection and fire alarm system capable of detecting a fire in the vehicle space promptly)
💡 SOLAS requires ro-ro and vehicle spaces to have a fixed fire detection and fire alarm system. Because these spaces are large and vehicles carry fuel, fire spreads rapidly, and periodic rounds alone would not detect it in time.
✗
Question 50. A PSCO checked the gyro compass error. What does SOLAS and the related standards require of the gyro compass?
Your Answer: (Not answered)
Correct Answer: C (It must indicate true north steadily with the error within the prescribed limits while the ship is under way)
💡 SOLAS V/19 requires the gyro compass to indicate true north steadily within prescribed error limits while the ship is under way and rolling, with regular checks and records during the voyage.
✗
Question 51. What is the main purpose of a ship reporting system?
Your Answer: (Not answered)
Correct Answer: B (Providing information for search and rescue and navigational safety)
💡 To provide information for SAR and navigational safety.
✗
Question 52. In a crossing situation, what determines who must keep out of the way?
Your Answer: (Not answered)
Correct Answer: D (The vessel which has the other on her starboard side must keep out of the way)
💡 Under the collision regulations when two power-driven vessels are crossing so as to involve risk of collision, the vessel which has the other on her starboard side must keep out of the way and should avoid crossing ahead of the other, while the stand-on vessel keeps her course and speed. The give-way vessel should act in ample time and obviously.
✗
Question 53. What should be done if abnormal heel develops during cargo operations?
Your Answer: (Not answered)
Correct Answer: D (Stop work at once, establish the cause such as cargo shift, flooding or uneven ballast, and then decide the course of action)
💡 If abnormal heel develops during cargo work, operations should stop immediately and the cause established, whether cargo has shifted, a compartment is flooding or the ballast is uneven, with stability and structural condition assessed before deciding what to do. Continuing could allow the heel to increase rapidly and cause capsize.
✗
Question 54. What must the enclosed space entry testing record contain under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (The date, location, parameters tested and results, and the issue of the permit)
💡 SOLAS and the IMO resolutions require records of enclosed space entry testing and permits, including the date, the space, the parameters tested — oxygen, toxic and flammable gases — the results and the permit issued, for traceability and inspection.
✗
Question 55. What do SOLAS and good practice address regarding monitoring hull deformation during cargo work on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: B (Monitoring hogging and sagging to prevent deformation exceeding the permitted range)
💡 SOLAS and good practice require hogging and sagging to be monitored during cargo work on a bulk carrier, judging from the loading instrument or draught readings whether stresses are within limits, preventing structural damage from excessive deformation.
✗
Question 56. What coordination is required when using tugs in confined waters?
Your Answer: (Not answered)
Correct Answer: C (Agree beforehand on the means of communication, the method of working and the command relationship, maintaining communication throughout)
💡 When tugs assist with berthing or manoeuvring in confined waters, the VHF channel, the position for taking the line, the direction of thrust and the command relationship should be agreed in advance, with communication maintained throughout, preventing a misunderstanding of orders from causing collision or damage.
✗
Question 57. What safety requirements apply to steam systems?
Your Answer: (Not answered)
Correct Answer: A (Insulation and marking of piping and valves, with safety valves and drains, preventing burns and overpressure)
💡 SOLAS and good practice require steam piping to be insulated and marked for temperature and steam valves and fittings to have safety valves and drains, preventing burns, overpressure and water hammer damage. Steam systems are hazardous and must be operated strictly under the procedure.
✗
Question 58. What should be noted about launching lifeboats while the ship has headway?
Your Answer: (Not answered)
Correct Answer: A (Reduce speed or stop if possible before launching, avoiding the boat being swept away or striking the hull)
💡 A lifeboat should be launched with speed reduced or the ship stopped where possible, since headway produces a flow that can sweep the boat away or dash it against the hull. If stopping is impossible in an emergency, the boat should be launched on the lee side with due preparation.
✗
Question 59. To which tankers does the emergency towing arrangement requirement of SOLAS II-1/3-3 apply?
Your Answer: (Not answered)
Correct Answer: D (Oil tankers of 20000 tonnes deadweight and above)
💡 SOLAS II-1/3-3 requires oil tankers of 20000 tonnes deadweight and above to be fitted with an emergency towing arrangement at bow and stern, so that a disabled tanker can be taken in tow. It is not limited to new ships.
✗
Question 60. The carriage of dangerous chemicals in bulk shall follow:
Your Answer: (Not answered)
Correct Answer: B (the International Bulk Chemical Code (IBC Code))
💡 SOLAS VII/7: the carriage of dangerous chemicals in bulk shall follow the IBC Code.
✗
Question 61. What should be noted about the use of distress signals during drills?
Your Answer: (Not answered)
Correct Answer: A (Signals should not be fired in a drill unless necessary; if fired, the direction and safety must be confirmed and the matter recorded)
💡 Distress signals are dangerous goods with a limited life. They are not normally fired in a drill, alternative means being used to check them. If firing is genuinely required, the direction and the safety of the surroundings must be confirmed, the bridge informed and the expenditure recorded, avoiding misunderstanding or danger.
✗
Question 62. How should training needs be identified and met?
Your Answer: (Not answered)
Correct Answer: C (Identified from the operation of the system, drills and inspections and then delivered)
💡 The ISM Code and STCW require the company and the ship to identify training needs from drill assessments, findings at inspection and the analysis of accidents and near misses, such as unfamiliarity with equipment or unclear emergency duties, and to organise targeted training and assessment, so that training matches the actual need.
✗
Question 63. What should be done with a fire hose after use?
Your Answer: (Not answered)
Correct Answer: A (Clean and dry it, then roll and stow it in the proper manner in place, keeping it ready for use)
💡 After use a fire hose should be washed free of oil and salt water, dried and then rolled and stowed in the proper manner in its position, preventing rot and ageing which affect pressure resistance. Stowing it damp or exposing it long term shortens its life.
✗
Question 64. A nozzle of the fixed CO2 fire extinguishing system is blocked by paint. The finding is?
Your Answer: (Not answered)
Correct Answer: B (The discharge path of the system is obstructed, a deficiency seriously affecting its effectiveness)
💡 A fixed fire extinguishing system relies on its nozzles to distribute the agent evenly through the protected space. A blocked nozzle prevents the agent from reaching the seat of fire, seriously weakening the system. It should be cleared at once and all nozzles of the system checked.
✗
Question 65. What familiarisation training is required for newly joined crew?
Your Answer: (Not answered)
Correct Answer: A (Completed before taking up duties, covering duties, the location and operation of equipment and emergency duties and procedures)
💡 The ISM Code and STCW require newly joined crew to complete familiarisation training before taking up their duties, covering their responsibilities on board, the location and operation of relevant equipment and emergency duties and procedures and safety and pollution prevention requirements, with records kept. Training after taking up duties is not acceptable.
✗
Question 66. The clear width of stairways forming means of escape shall generally be not less than:
Your Answer: (Not answered)
Correct Answer: C (800 mm)
💡 SOLAS II-2/13 generally requires the clear width of escape stairways to be not less than 800 mm.
✗
Question 67. How must revisions of system documentation be managed?
Your Answer: (Not answered)
Correct Answer: D (Approved by authorised persons, issued promptly, superseded versions withdrawn and the crew informed)
💡 The ISM Code requires revisions of system documentation to be approved by authorised persons and issued in a controlled way, with the version and effective date shown and superseded versions withdrawn or marked as obsolete, and the crew informed so that they work to the latest version. Uncontrolled amendment leaves different versions in use on board.
✗
Question 68. What does SOLAS address regarding electrical equipment in a paint locker?
Your Answer: (Not answered)
Correct Answer: C (Explosion-protected equipment or no electrical equipment within the space)
💡 SOLAS requires explosion-protected equipment in a paint locker, or no electrical equipment inside it, such as lighting fitted outside, preventing an electrical spark from igniting paint vapour.
✗
Question 69. What principle governs the selection of electrical equipment within the cargo area of a tanker?
Your Answer: (Not answered)
Correct Answer: D (Equipment of an explosion-protected type appropriate to the hazard level of the area must be used)
💡 SOLAS II-2 requires electrical equipment in hazardous areas of a tanker to be of an explosion-protected type suited to the hazard level. Ordinary equipment is not permitted even with more frequent inspection.
✗
Question 70. For how long shall a VDR retain its recorded data as a minimum?
Your Answer: (Not answered)
Correct Answer: B (12 hours)
💡 SOLAS V/20: the VDR shall retain at least the last 12 hours of data.
✗
Question 71. Survival craft shall be capable of rapid launching:
Your Answer: (Not answered)
Correct Answer: B (under unfavourable conditions of trim and list)
💡 SOLAS III/16 requires rapid launching under unfavourable conditions of trim and list.
✗
Question 72. What safety management is required for modifications to equipment?
Your Answer: (Not answered)
Correct Answer: A (Assess the risk and compliance, obtain the necessary approval, revise documentation and train the crew before the modification)
💡 Before modifying the ship's equipment or structure a risk and compliance assessment should be carried out, considering any effect on certificates and statutory requirements, approval obtained from the classification society or Administration where statutory matters are involved, the documentation and procedures revised and the crew trained, preventing non-compliance or incorrect operation afterwards.
✗
Question 73. A section of the fire detection system fails to alarm during testing. What should be done?
Your Answer: (Not answered)
Correct Answer: C (Establish the cause at once, such as a failed detector, broken wiring or incorrect zoning, and repair it)
💡 A section that does not alarm means a fire there would not be detected in time. The cause must be established at once, whether a failed detector, broken wiring, incorrect zoning or an inhibited circuit, and repaired. Disabling the section or relying on another leaves a serious latent hazard.
✗
Question 74. What is the purpose of the rudder angle indicator?
Your Answer: (Not answered)
Correct Answer: C (Showing the actual rudder angle)
💡 It shows the actual rudder angle.
✗
Question 75. What is required when new piping is passed through a fire division during a conversion?
Your Answer: (Not answered)
Correct Answer: D (Execute the approved penetration sealing arrangement, updating the fire control plan and records)
💡 New penetrations of a fire division require the approved penetration sealing arrangement to be used, with approved seals of equivalent fire rating, while the fire control plan and records are updated and the work verified by the classification society. A plain hole or cement sealing destroys the fire integrity of the division.
✗
Question 76. Which ships does the International Safety Management Code reach?
Your Answer: (Not answered)
Correct Answer: A (every class of ship to which the Convention applies, together with their companies - passenger ships, tankers, chemical carriers and bulk carriers included)
💡 The Code runs along the Convention's own scope rather than sorting by ship type: passenger ships, cargo ships (tankers, chemical and gas carriers, bulk carriers among them) and mobile offshore drilling units required by the Convention, together with the companies that operate them, must all have a system. The certificate is issued to the ship (the Safety Management Certificate), but the system is built at company level, which is why companies and ships enter the scope together. Reading the Code as reaching one type of ship only usually means it has been confused with the ship-type technical provisions.
✗
Question 77. How many lifebuoys shall be fitted with self-igniting lights and self-activating smoke signals?
Your Answer: (Not answered)
Correct Answer: D (Two)
💡 At least two, capable of quick release from the bridge.
✗
Question 78. What do the blind sector limitations of SOLAS V/22 principally concern?
Your Answer: (Not answered)
Correct Answer: A (The total arc and individual arcs of blind sectors ahead as seen from the conning position)
💡 SOLAS V/22 limits the number and total arc of blind sectors ahead from the conning position so that the look-out remains effective. It does not deal with radar shadows or window reflection.
✗
Question 79. What does SOLAS specifically require regarding the correction of nautical charts and publications?
Your Answer: (Not answered)
Correct Answer: B (They must be corrected promptly from notices to mariners, with a record of the corrections kept)
💡 SOLAS V/27 requires charts and nautical publications to be corrected promptly from notices to mariners with a record kept, such as a chart correction log. Late or missing correction is a common ground for detention.
✗
Question 80. What does the weather criterion of the intact stability code examine?
Your Answer: (Not answered)
Correct Answer: B (a gust heeling lever added to that of the steady wind, the angle of heel and the downflooding angle retaining adequate margin)
💡 The criterion splits the wind into a steady pressure and a gust: the ship heels under the steady heeling lever and the gust pushes her further, the area under the righting lever curve having to exceed that under the wind levers, the gust heel staying within the fraction of the downflooding angle and inside the stated limit. Metacentric height or roll period alone cannot answer that question.
✗
Question 81. What does SOLAS address regarding the subdivision of bilge drainage arrangements?
Your Answer: (Not answered)
Correct Answer: A (The bilge system must be arranged in sections so that water in any compartment can be drained independently)
💡 SOLAS requires the bilge system to be arranged in sections with independent suctions, so that water in any compartment can be drained on its own without affecting others, and the location of flooding can be identified. A single central suction does not meet the requirement.
✗
Question 82. Bulk carriers of 150 m and above must be fitted with a loading instrument. What is its purpose?
Your Answer: (Not answered)
Correct Answer: A (To calculate hull stress and intact stability during loading and unloading)
💡 SOLAS XII/11 requires the loading instrument for calculating hull stresses and intact stability during cargo work, preventing structural damage from overloading or incorrect sequence. Water level detection is a separate requirement.
✗
Question 83. What number of thermal protective aids must a lifeboat carry under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (10 per cent of the rated number of persons, and not fewer than two)
💡 SOLAS requires a lifeboat to carry thermal protective aids for 10 per cent of the rated number of persons, and not fewer than two. An insufficient number leaves some persons without thermal protection in cold conditions.
✗
Question 84. The self-contained breathing apparatus in a firefighter's outfit shall be capable of being used for at least:
Your Answer: (Not answered)
Correct Answer: C (30 minutes)
💡 SOLAS II-2/10: the self-contained breathing apparatus in a firefighter's outfit shall be capable of being used for at least 30 minutes.
✗
Question 85. What is the minimum number of two-way VHF radiotelephone sets for a cargo ship?
Your Answer: (Not answered)
Correct Answer: A (Three, with at least one on each side)
💡 Under SOLAS IV/7 a cargo ship should carry at least three two-way VHF radiotelephone sets, with at least one on each side and the remainder stowed such as on the bridge, so that they can be taken into the respective survival craft for on-scene communication during abandonment.
✗
Question 86. A 4200 GT cargo ship on international voyages has three pumps in the machinery space. Under SOLAS II-2/10.2, what is the minimum fire pump arrangement?
Your Answer: (Not answered)
Correct Answer: B (At least two independently driven fire pumps)
💡 SOLAS II-2/10.2 requires cargo ships of 1000 GT and above to have at least two independently driven fire pumps. At 4200 GT the ship is well above the threshold, so two is the minimum.
✗
Question 87. How often shall the Company carry out internal audits of the SMS?
Your Answer: (Not answered)
Correct Answer: A (At least once a year)
💡 At least once a year.
✗
Question 88. Within what time shall the emergency generator start and supply power automatically on loss of the main supply?
Your Answer: (Not answered)
Correct Answer: D (30 seconds)
💡 SOLAS II-1/44: the emergency generator shall start automatically within 30 seconds.
✗
Question 89. What are the stowage and inspection interval requirements for the firefighter's outfits?
Your Answer: (Not answered)
Correct Answer: A (They should be stowed where they are readily available and protected from damage, and inspected for completeness at the required intervals)
💡 Firefighter's outfits should be stowed where they are readily available and protected from heat, damp and damage, and inspected at the required intervals, such as weekly or monthly, for the condition of the protective clothing, helmet, safety lamp, axe and breathing apparatus and for adequate cylinder pressure, with records kept.
✗
Question 90. In the subdivision of a passenger ship, what does the "subdivision load line" mean?
Your Answer: (Not answered)
Correct Answer: D (An assumed load line used to determine subdivision requirements, not the ship's actual service load line)
💡 The subdivision load line is an assumed load line used in determining subdivision requirements such as bulkhead positions and the subdivision index. It is a different concept from the summer or tropical load lines actually used in service.
✗
Question 91. When ECDIS is used to satisfy the carriage of charts requirement, the ship must also have:
Your Answer: (Not answered)
Correct Answer: A (Appropriate back-up arrangements)
💡 SOLAS V/19: ECDIS may satisfy chart carriage only if appropriate back-up arrangements are provided.
✗
Question 92. The length of a fire hose in a machinery space shall generally not exceed:
Your Answer: (Not answered)
Correct Answer: C (15 m)
💡 SOLAS II-2/10 requires hose length in machinery spaces not to exceed 15 m.
✗
Question 93. The scrubber in an inert gas system mainly functions to:
Your Answer: (Not answered)
Correct Answer: C (cool and purify the inert gas, removing sulphur compounds and water)
💡 SOLAS II-2/5 requires a scrubber to cool and purify the inert gas, removing sulphur dioxide and moisture.
✗
Question 94. What should be done after a water ingress alarm on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (Identify the flooded hold, assess the effect on stability and strength and take measures such as pumping or adjustment, reporting as required)
💡 On a water ingress alarm the flooded hold and the cause should be established at once, such as hatch leakage, hull damage or piping leakage, the effect on stability, strength and draught assessed and measures taken such as pumping, adjusting ballast or reducing cargo, with the company and the Administration informed under the SMS.
✗
Question 95. What quantity of fresh water is provided per person in the equipment of a lifeboat?
Your Answer: (Not answered)
Correct Answer: A (Three litres per person)
💡 Under SOLAS III/34 and the equipment requirements for lifeboats, three litres of fresh water should be provided for each person the boat is permitted to accommodate. Fresh water and food are basic provisions for survival after abandonment and a drinking vessel should also be provided.
✗
Question 96. How should hazard identification and risk assessment be carried out on board?
Your Answer: (Not answered)
Correct Answer: B (Identify hazards and assess risks for shipboard operations and equipment and take control measures accordingly)
💡 The ISM Code requires hazard identification and risk assessment on board for operations and equipment, covering routine and non-routine work and new equipment and new operations, from which control measures are decided and incorporated into procedures and checklists, bringing risks under control in advance.
✗
Question 97. What is the final means required by SOLAS if the main steering power is completely lost?
Your Answer: (Not answered)
Correct Answer: B (An approved alternative steering arrangement such as an emergency tiller or independent power-driven emergency steering)
💡 SOLAS requires an approved alternative steering arrangement, such as an emergency tiller or an independent power-driven emergency steering gear, usable in an emergency, with regular drills so the crew can operate it.
✗
Question 98. What is the primary fire safety objective of SOLAS Chapter II-2?
Your Answer: (Not answered)
Correct Answer: A (To prevent the occurrence and spread of fire)
💡 The primary objective is to prevent fires and limit their spread.
✗
Question 99. How should true and relative motion radar displays be chosen?
Your Answer: (Not answered)
Correct Answer: A (Choose the display suited to the appreciation required and be able to interpret the target's movement correctly)
💡 True and relative motion displays each have their use: relative motion allows the risk of collision and CPA to be judged quickly, while true motion shows the actual tracks of targets and the ship's position relative to them. The officer should be able to choose and interpret correctly, avoiding a wrong appreciation.
✗
Question 100. What do SOLAS and good practice address regarding fire safety in boiler spaces?
Your Answer: (Not answered)
Correct Answer: C (Quick closing valves and ventilation shut-off arrangements, with guarding and alarms around the boiler)
💡 SOLAS requires quick closing valves and ventilation shut-off arrangements in boiler spaces, with guarding around the boiler, preventing leaking fuel from being ignited by heat. The boiler space is a high fire risk location in the machinery space.