Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. Navigational notices received on board have not been applied for a long period. What does SOLAS V/27 require?
Your Answer: (Not answered)
Correct Answer: B (Charts and publications shall be adequate and kept up to date)
💡 SOLAS V/27 requires ships to carry and maintain adequate and up-to-date charts and nautical publications, corrected from notices to mariners. Failure to correct is a deficiency.
✗
Question 2. What is required regarding the stability information at a renewal survey?
Your Answer: (Not answered)
Correct Answer: D (Verify that it agrees with the actual condition of the ship and update it if the loading conditions have changed)
💡 SOLAS requires the approved stability information to be verified at survey as agreeing with the actual condition of the ship, structure, equipment and loading conditions. Where the ship is converted, the loading method changes or the weight distribution alters, the information should be updated and approved.
✗
Question 3. What do GMDSS procedures require regarding relaying a distress alert?
Your Answer: (Not answered)
Correct Answer: A (Where the casualty cannot establish communication or the alert has not been acknowledged, a ship receiving it must relay the alert)
💡 GMDSS procedures require a ship receiving a distress alert to relay it where a coast station has not acknowledged it, the casualty cannot establish reliable communication, or relaying would help. The alert must reach the search and rescue service.
✗
Question 4. What rowing equipment shall a liferaft carry?
Your Answer: (Not answered)
Correct Answer: D (Oars suitable for rowing)
💡 Oars shall be provided so the raft can be moved short distances.
✗
Question 5. What is the purpose of a ship's echo sounder?
Your Answer: (Not answered)
Correct Answer: D (To measure the depth of water from the keel to the seabed, assisting navigation, positioning and shallow-water warning)
💡 Under SOLAS V/19 a ship of 3000 gross tonnage and above should be provided with an echo sounder to measure the depth of water from the keel to the seabed, assisting in judging depth changes, giving shallow-water warning and cross-checking position, especially useful in shoal areas, at anchor and when berthing.
✗
Question 6. What is required in responding to a chemical cargo leak on a chemical tanker?
Your Answer: (Not answered)
Correct Answer: A (Follow the measures in the cargo emergency schedule (EmS), including protection, containment, collection and neutralisation, not using water indiscriminately)
💡 A chemical leak requires the measures in the EmS and the safety data sheet to be followed, since chemicals react differently with water, some generating heat or toxic gas. Using water without regard to the chemical may make the situation worse.
✗
Question 7. What are the common risks in launching and recovering survival craft?
Your Answer: (Not answered)
Correct Answer: A (Inadvertent operation of the release gear dropping the boat and injuring persons, and persons being crushed between the falls and the boat)
💡 The principal risks in launching and recovering a lifeboat include the release gear operating inadvertently and dropping the boat, persons being crushed between the falls and the boat and the boat striking the ship's side. Procedures should be strictly followed, coordination maintained and positions chosen with care.
✗
Question 8. What does SOLAS address regarding the remote control system of the main engine?
Your Answer: (Not answered)
Correct Answer: C (The main engine must be controllable from the bridge and the machinery control room, with reliable transfer between positions with indication and alarms)
💡 SOLAS requires the main engine to be controllable from both the bridge and the machinery control room, with reliable transfer between control positions and appropriate indication and alarms, preventing loss of control or misoperation during transfer.
✗
Question 9. What shall the bridge be able to indicate for watertight doors?
Your Answer: (Not answered)
Correct Answer: C (Whether each door is open or closed)
💡 The bridge shall indicate whether remotely controlled doors are open or closed.
✗
Question 10. Which principle applies to the stowage of survival craft?
Your Answer: (Not answered)
Correct Answer: D (They must be readily available and capable of being launched and boarded rapidly and safely in an emergency)
💡 Under SOLAS III/13 survival craft should be stowed in a position where they are readily available and can be launched and boarded rapidly and safely, protected from the effects of fire and explosion, the arrangement of the craft and their launching and boarding appliances ensuring that in an emergency persons can muster, board and clear quickly.
✗
Question 11. Why shall spaces where flammable gases may accumulate be ventilated?
Your Answer: (Not answered)
Correct Answer: B (To prevent gases reaching dangerous concentrations)
💡 To prevent accumulation of flammable gases to dangerous concentrations.
✗
Question 12. Which statement about the enhanced programme of inspections for tankers and bulk carriers is correct?
Your Answer: (Not answered)
Correct Answer: B (It prescribes stricter close-up examination and thickness measurement, and requires a survey planning document)
💡 The ESP requires a survey planning document identifying the extent of close-up surveys and thickness measurements, and is stricter than routine surveys. Its application is not determined solely by an age of 20 years.
✗
Question 13. What are the key points in checking the falls of a launching appliance?
Your Answer: (Not answered)
Correct Answer: C (Check for broken wires, corrosion, deformation and the security of the terminations, replacing when beyond the limit)
💡 The falls of a launching appliance should be checked for the number of broken wires, corrosion, kinks and deformation and for the security of the terminations, replaced at once when beyond the rejection criteria. Failure of the falls would drop the craft during launching with fatal consequences.
✗
Question 14. Which high risk areas do SOLAS and the ESP require to be examined on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Hatch covers, the internal structure of top side and hopper side tanks and the corrosion and cracking of bulkheads and side structure)
💡 The ESP and SOLAS require close-up examination and thickness measurement of hatch covers, the internal structure of top side and hopper side tanks and the stiffening of bulkheads and sides, since these areas corrode readily and directly affect the longitudinal strength of the hull.
✗
Question 15. The loading of solid bulk cargoes shall:
Your Answer: (Not answered)
Correct Answer: A (comply with the IMSBC Code, taking account of cargo properties)
💡 SOLAS VI/6 requires loading of solid bulk cargoes in accordance with the IMSBC Code.
✗
Question 16. A voyage data recorder (VDR) shall be capable of retaining data for the preceding:
Your Answer: (Not answered)
Correct Answer: C (12 hours)
💡 SOLAS V/20: a VDR shall be capable of retaining data for at least the preceding 12 hours in a protective storage unit.
✗
Question 17. How does the survey programme change as a bulk carrier ages under SOLAS and the ESP?
Your Answer: (Not answered)
Correct Answer: D (The scope and frequency increase with age, particularly close-up survey and thickness measurement)
💡 The ESP prescribes the survey scope by age band, requiring more as the ship grows older, including wider close-up survey and thickness measurement, to assess corrosion and fatigue and decide on repair or reinforcement.
✗
Question 18. What is the principal risk addressed by the requirements for venting arrangements of tanker cargo tanks?
Your Answer: (Not answered)
Correct Answer: B (Preventing overpressure or vacuum in the tanks caused by cargo operations and temperature changes)
💡 Venting arrangements equalise tank pressure during cargo operations and temperature changes, preventing structural damage from overpressure and deformation from vacuum.
✗
Question 19. What should be noted about using survival craft at low temperature in polar waters?
Your Answer: (Not answered)
Correct Answer: B (Difficulty in starting engines, reduced battery capacity and changed equipment performance, with insulation and pre-heating measures taken)
💡 Using survival craft in polar conditions requires attention to difficulty in starting engines, addressed by insulation, pre-heating and oil suited to low temperature, reduced battery capacity, addressed by insulation or spares, changed performance of equipment and the risk of hypothermia, with plans and drills in place.
✗
Question 20. A ship is to load dangerous goods but lacks the emergency information required. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (Obtain the EmS Guide, MFAG and other emergency information before loading; otherwise refuse to load)
💡 SOLAS VII requires a ship carrying dangerous goods to have the EmS Guide, MFAG and similar emergency information. Without it the master should not agree to load. Loading first and supplying the information afterwards would leave the ship unable to respond effectively to an incident, a breach.
✗
Question 21. Segregation is required when dangerous goods are stowed on board. What is the fundamental purpose?
Your Answer: (Not answered)
Correct Answer: B (To prevent incompatible substances reacting dangerously on contact)
💡 Segregation under SOLAS VII/3 and the IMDG Code prevents incompatible substances from reacting if released, causing fire, explosion or toxic gas. It is not a tallying convenience.
✗
Question 22. The recording device of an inert gas system may record:
Your Answer: (Not answered)
Correct Answer: B (oxygen content, gas pressure and time)
💡 SOLAS II-2/5 requires continuous recording of oxygen content, gas pressure and time.
✗
Question 23. What are the key points in using a portable extinguisher?
Your Answer: (Not answered)
Correct Answer: D (Pull the pin, aim the nozzle at the base of the fire and sweep while pressing the lever)
💡 Using a portable extinguisher involves pulling the pin, holding the nozzle and aiming at the base of the fire, that is the burning surface, then sweeping while pressing the lever. Aiming at the top of the flames is ineffective, and the position should allow a line of retreat.
✗
Question 24. After grounding, what should the master give priority to?
Your Answer: (Not answered)
Correct Answer: D (Ascertain the extent of flooding and damage, assess stability and pollution risk, prevent further damage and pollution and report)
💡 After grounding the first priority is to ascertain the flooding of compartments, the damage to the hull and the ship's position, assess stability, the grounding forces and the pollution risk, and take measures to prevent further damage and pollution, such as closing watertight doors, controlling draught and trim, informing those concerned and reporting. Forcing a refloat at once may worsen the damage and must be carefully assessed.
✗
Question 25. Under SOLAS V/33, the master:
Your Answer: (Not answered)
Correct Answer: A (shall proceed with all speed to assist upon receiving a distress message, unless doing so would seriously endanger the ship and persons on board)
💡 SOLAS V/33: the master shall proceed with all speed to assist upon receiving a distress message unless doing so would seriously endanger the ship and persons on board.
✗
Question 26. What is the purpose of AIS?
Your Answer: (Not answered)
Correct Answer: B (Automatic broadcast and reception of ship identification and navigational information)
💡 To broadcast and receive ship identification and navigational information automatically.
✗
Question 27. What does SOLAS address regarding drainage of ro-ro spaces?
Your Answer: (Not answered)
Correct Answer: A (Effective drainage removing firefighting water and leaked oil promptly)
💡 SOLAS requires ro-ro spaces to have effective drainage and storage arrangements able to remove firefighting water and leaked oil promptly, preventing free surface from affecting stability and reducing the risk of oil spreading the fire.
✗
Question 28. For internal combustion engines in machinery spaces, which requirement of the fuel system shall be met?
Your Answer: (Not answered)
Correct Answer: A (high-pressure fuel pipes shall be protected to prevent fuel spraying)
💡 SOLAS II-2/4 requires high-pressure fuel pipes to be protected to prevent spray of fuel onto hot surfaces or ignition.
✗
Question 29. What is required regarding mutual supervision and assistance among the crew?
Your Answer: (Not answered)
Correct Answer: B (Encouraged, particularly in high risk work, creating a mutual safety climate)
💡 Good safety practice encourages the crew to remind, watch over and correct one another in high risk work such as work at height, enclosed space entry and hot work, creating a mutual safety climate in which an individual lapse can be noticed and stopped by another.
✗
Question 30. What should be noted about fog signals in restricted visibility?
Your Answer: (Not answered)
Correct Answer: A (Sound fog signals as COLREG prescribes and listen attentively to other vessels' signals to judge bearing and movement)
💡 In restricted visibility fog signals should be sounded as COLREG prescribes, for example one prolonged blast at intervals of not more than two minutes for a power-driven vessel under way, while listening carefully to other vessels' signals to judge their approximate bearing and movement, combined with radar observation. Sounding must not be delayed.
✗
Question 31. How should a lifeboat be launched?
Your Answer: (Not answered)
Correct Answer: D (Controlled from within the boat (gravity davit) with the lowering speed controlled and the boat kept steady)
💡 A lifeboat is launched under control from within the boat, with a release arrangement in the boat for a gravity davit. The lowering speed should be controlled, contact with the ship's side prevented and the boat turned and cleared for release before entering the water. Too fast a descent causes casualties and structural damage.
✗
Question 32. How must a ship fulfil the duty to render assistance at sea under SOLAS V?
Your Answer: (Not answered)
Correct Answer: A (To proceed with all speed to render assistance where there is reasonable ground to believe another ship is in distress, and to inform the owner or agent)
💡 SOLAS requires the master to proceed with all speed to render assistance where there is reasonable ground to believe a ship is in distress, and to inform the owner or agent. Assistance is a legal duty.
✗
Question 33. A nozzle of the fixed CO2 fire extinguishing system is blocked by paint. The finding is?
Your Answer: (Not answered)
Correct Answer: B (The discharge path of the system is obstructed, a deficiency seriously affecting its effectiveness)
💡 A fixed fire extinguishing system relies on its nozzles to distribute the agent evenly through the protected space. A blocked nozzle prevents the agent from reaching the seat of fire, seriously weakening the system. It should be cleared at once and all nozzles of the system checked.
✗
Question 34. What do SOLAS and good practice address regarding operational testing of a fixed foam system?
Your Answer: (Not answered)
Correct Answer: C (Periodic inspection of piping and nozzles and, as required, a discharge test to confirm the system works)
💡 SOLAS and good practice require periodic inspection of the piping, valves and nozzles of a fixed foam system for obstruction, with a discharge test as required, confirming that the system will operate when needed.
✗
Question 35. What are the core documents of the safety management system required by SOLAS Chapter IX?
Your Answer: (Not answered)
Correct Answer: A (A safety management manual together with supporting procedures covering the elements of the system)
💡 SOLAS IX and the ISM Code require a safety management manual with supporting procedures covering the elements of the Code. A policy statement or a single plan does not constitute a complete system.
✗
Question 36. What power supply does SOLAS require for a fixed fire detection system?
Your Answer: (Not answered)
Correct Answer: B (Supplied from both the main and the emergency source, with automatic change-over if the main source fails)
💡 SOLAS requires the fixed fire detection system to be supplied from both the main and the emergency sources with automatic change-over if the main source fails, so that detection continues to work during a blackout.
✗
Question 37. What do SOLAS and good practice address regarding insulation resistance of ship's electrical equipment?
Your Answer: (Not answered)
Correct Answer: A (Periodic measurement and recording of insulation resistance, investigating and rectifying any decline)
💡 SOLAS and good practice require periodic measurement and recording of insulation resistance. A fall in insulation resistance usually indicates moisture, ageing or damage, and early detection prevents short circuits and electrical fire.
✗
Question 38. What do SOLAS and good practice address regarding watertight doors kept open while in port?
Your Answer: (Not answered)
Correct Answer: A (They may be opened as required for operations, but must remain capable of immediate closing with attention to changes in the ship's condition)
💡 Some watertight doors may be opened in port for cargo work or access, but must remain capable of being closed at once, with their status indicated on the bridge, and must be closed again if the ship's condition changes, such as draught change during cargo work, preventing inadvertent flooding.
✗
Question 39. How does the damage stability requirement for bulk carriers differ from that for ordinary cargo ships?
Your Answer: (Not answered)
Correct Answer: C (Residual stability must be calculated assuming flooding of a cargo hold, so that the ship survives under the assumed condition)
💡 SOLAS XII requires the residual stability and strength of a bulk carrier to be assessed assuming flooding of one cargo hold, taking the density of the cargo into account. Ordinary cargo ships have no equivalent provision.
✗
Question 40. What is the purpose of the voyage data recorder required by SOLAS V/19?
Your Answer: (Not answered)
Correct Answer: C (To provide data on the navigation and operation of the ship for accident investigation)
💡 The VDR records navigational and operational data for use in casualty investigation. The data is protected and must not be used for crew assessment or other purposes.
✗
Question 41. Extension of a certificate is permitted:
Your Answer: (Not answered)
Correct Answer: B (only in special circumstances when the ship is not in a port of survey, as authorized by the Administration)
💡 SOLAS I/14: extension of a certificate is permitted only in special circumstances when the ship is not in a port of survey.
✗
Question 42. Who decides to abandon ship?
Your Answer: (Not answered)
Correct Answer: B (The master, after assessing the condition of the ship; no one else may abandon her)
💡 The decision to abandon ship rests with the master, taken after assessing flooding, fire, stability and the possibility of rescue. Abandoning without authority would squander the chance of saving the ship and expose persons to the dangers of the sea, a serious breach.
✗
Question 43. During the voyage the temperature records for a solid bulk cargo show a steady rise. What treatment of the matter is acceptable for the master?
Your Answer: (Not answered)
Correct Answer: C (testing made more frequent and the cause looked into, ventilation or sealing decided by what the cargo schedule requires, company and port informed)
💡 The Code prescribes different treatment by cargo: some self-heating materials want surface ventilation to carry heat off, others must have air restricted so the oxygen does not feed the reaction, and carbon dioxide is released in one dose to the designed concentration once the space is proved clear and tight. The basis is the proper name, the moisture and the trend, not the single clue of a rising thermometer; opening a hold can also bring smoke back over the working party. Closer record-keeping, report and measurement are the practical ship's side of it.
✗
Question 44. What measures do SOLAS and the IMSBC Code require for solid bulk cargoes liable to self-heat or release harmful gas?
Your Answer: (Not answered)
Correct Answer: A (Obtain full cargo information before loading, increase ventilation and gas testing and restrict entry into the holds)
💡 The IMSBC Code requires precautions for cargoes liable to self-heat or release harmful gas: full cargo information, increased ventilation and gas testing, restricted entry into the holds and emergency preparation, preventing spontaneous combustion, poisoning or explosion.
✗
Question 45. What does SOLAS address regarding the equilibrium condition in damage stability calculations?
Your Answer: (Not answered)
Correct Answer: B (After flooding the ship must satisfy the residual stability criteria in the equilibrium condition)
💡 SOLAS requires that, once the ship reaches equilibrium after flooding, taking account of the water entered and the resulting heel, the residual stability curve satisfies the prescribed criteria such as the range of righting levers and the maximum righting lever. Intact stability criteria alone are not a substitute.
✗
Question 46. What is required in controlling trim during loading?
Your Answer: (Not answered)
Correct Answer: A (Maintain an appropriate stern trim or even keel, avoiding excessive trim affecting manoeuvrability, speed and structural stress)
💡 A moderate stern trim favours propeller efficiency and rudder response, but excessive trim by the stern or by the head reduces forward freeboard or lifts the propeller out, affecting manoeuvrability and speed and increasing structural stress. Trim should be controlled according to the stability and strength information.
✗
Question 47. What is required when fire and abandon ship drills are combined?
Your Answer: (Not answered)
Correct Answer: A (They may be combined where reasonable and practicable, provided the objectives of each are achieved without omitting essential elements)
💡 SOLAS permits drills of different kinds to be combined where reasonable and practicable, provided that the objectives of each, such as preparing and launching survival craft in an abandon ship drill and firefighting and rescue in a fire drill, are fully achieved. Essential elements must not be omitted because the drills are combined.
✗
Question 48. Before departure the master shall ensure that:
Your Answer: (Not answered)
Correct Answer: D (the ship's stability and trim are satisfactory)
💡 SOLAS II-1/5 requires the master to verify stability and trim before departure.
✗
Question 49. What stability concern does SOLAS address when a ship encounters deck seas or ice accretion?
Your Answer: (Not answered)
Correct Answer: B (Assess the adverse effect of water on deck and ice accretion on stability and freeboard and take measures)
💡 SOLAS and the Load Line Convention require account to be taken of the added weight of water on deck and ice accretion and their effect on stability and freeboard, with measures such as reducing deck cargo or altering course to reduce risk.
✗
Question 50. An emergency steering drill was held and direct steering from the steering gear compartment was required. What do SOLAS and STCW require?
Your Answer: (Not answered)
Correct Answer: A (An emergency steering drill at least every three months, including direct steering from the steering gear compartment and the communication procedure)
💡 SOLAS and STCW require emergency steering drills at least every three months, practising direct steering from the steering gear compartment and the communication procedure with the bridge, so that the crew can respond if steering control fails. A briefing is not a substitute.
✗
Question 51. SOLAS requires that the main propulsion machinery be:
Your Answer: (Not answered)
Correct Answer: A (controllable from the navigation bridge and also from the machinery space)
💡 SOLAS II-1 requires the main propulsion machinery to be controlled from the navigation bridge as well as from the machinery space.
✗
Question 52. What is required of drinking water containers in survival craft?
Your Answer: (Not answered)
Correct Answer: D (Hygienic containers preventing contamination, with the water renewed as prescribed)
💡 SOLAS requires survival craft to have hygienic containers for fresh water, preventing contamination and deterioration, with the water renewed at the prescribed servicing intervals. Water not renewed for a long time becomes undrinkable and affects survival.
✗
Question 53. How shall cargo units be loaded and secured?
Your Answer: (Not answered)
Correct Answer: B (So as to withstand the forces expected during the voyage without shifting)
💡 So as to withstand expected forces without shifting.
✗
Question 54. A renewal survey shall normally be completed within how long before the expiry of the existing certificate?
Your Answer: (Not answered)
Correct Answer: B (three months before expiry)
💡 SOLAS I/6: a renewal survey shall normally be completed within three months before the expiry of the existing certificate.
✗
Question 55. What is the principal concern of SOLAS XII regarding cargo hatch covers of bulk carriers?
Your Answer: (Not answered)
Correct Answer: B (They must remain weathertight and structurally adequate, preventing sea water entering holds and causing structural failure)
💡 SOLAS XII requires hatch covers of bulk carriers to be weathertight and of adequate strength. Failure of hatch covers allowing sea water into the holds is a major cause of structural failure and loss of bulk carriers.
✗
Question 56. What principle governs the selection of electrical equipment within the cargo area of a tanker?
Your Answer: (Not answered)
Correct Answer: D (Equipment of an explosion-protected type appropriate to the hazard level of the area must be used)
💡 SOLAS II-2 requires electrical equipment in hazardous areas of a tanker to be of an explosion-protected type suited to the hazard level. Ordinary equipment is not permitted even with more frequent inspection.
✗
Question 57. In radiocommunication, what is the priority of distress communication?
Your Answer: (Not answered)
Correct Answer: B (It has the highest priority above all other communication, which must give way to it)
💡 Under the Radio Regulations and the GMDSS distress communication has the highest priority and all other communication must give way and keep silence while it is in progress. A ship receiving a distress alert or distress traffic must not use the distress frequencies for non-distress communication.
✗
Question 58. What do SOLAS and good practice recommend for the handling of survival craft after abandonment?
Your Answer: (Not answered)
Correct Answer: B (Move clear of the ship as soon as possible, avoiding suction by the sinking ship or being trapped by burning oil)
💡 After abandonment, survival craft should be moved clear of the ship as soon as possible, avoiding the suction of a sinking ship, falling debris or being surrounded by burning oil. Remaining close to the ship greatly increases the danger.
✗
Question 59. What should be noted about the use of distress signals during drills?
Your Answer: (Not answered)
Correct Answer: A (Signals should not be fired in a drill unless necessary; if fired, the direction and safety must be confirmed and the matter recorded)
💡 Distress signals are dangerous goods with a limited life. They are not normally fired in a drill, alternative means being used to check them. If firing is genuinely required, the direction and the safety of the surroundings must be confirmed, the bridge informed and the expenditure recorded, avoiding misunderstanding or danger.
✗
Question 60. What does COLREG require for crossing a traffic lane in a routeing scheme?
Your Answer: (Not answered)
Correct Answer: C (Cross as nearly as practicable at right angles to the lane and avoid impeding vessels following the lane)
💡 COLREG Rule 10 requires a vessel crossing a traffic lane to do so as nearly as practicable at right angles to the general direction of traffic flow and to avoid impeding vessels following the lane. Diagonal or contrary navigation disrupts the flow and increases the risk of collision.
✗
Question 61. Radio antennas shall be so installed that they can operate:
Your Answer: (Not answered)
Correct Answer: A (under all weather conditions with adequate protection)
💡 SOLAS IV/13 requires radio antennas to operate under all weather conditions with adequate protection.
✗
Question 62. The carriage of liquefied gases in bulk shall follow:
Your Answer: (Not answered)
Correct Answer: B (the International Gas Carrier Code (IGC Code))
💡 SOLAS VII/11: the carriage of liquefied gases in bulk shall follow the IGC Code.
✗
Question 63. What does SOLAS address regarding earthing of the ship's electrical system?
Your Answer: (Not answered)
Correct Answer: B (Earth fault detection and protection must be provided to avoid electric shock and electrical fire)
💡 SOLAS requires means for earth fault detection and protection in the ship's electrical system, detecting insulation deterioration or earth faults in good time and preventing electric shock and electrical fire.
✗
Question 64. What is required for the batteries of two-way VHF radiotelephones in survival craft?
Your Answer: (Not answered)
Correct Answer: D (Capacity meeting the required operating time, with periodic testing and replacement)
💡 SOLAS requires the batteries of two-way VHF sets to have capacity for the prescribed operating time, with periodic testing and replacement. Neglecting this means the equipment may not work on abandonment.
✗
Question 65. What does SOLAS address regarding the watertight integrity of spaces above the bulkhead deck?
Your Answer: (Not answered)
Correct Answer: C (Openings must be fitted with effective closing appliances to prevent sea water entering the hull through them)
💡 SOLAS requires openings such as doors, side scuttles and ventilators above the bulkhead deck to have effective closing appliances, preventing sea water from entering the hull and causing loss of stability.
✗
Question 66. Where must the equipment of a lifeboat be stowed?
Your Answer: (Not answered)
Correct Answer: C (Inside the boat in designated positions, secured to prevent loss or injury if the boat capsizes)
💡 SOLAS requires the equipment of a lifeboat to be stowed inside the boat in designated positions, such as a locker or secured by lashings, preventing loss or injury if the boat capsizes or during launching. The equipment belongs with the boat and must not be kept on the parent ship.
✗
Question 67. What limitation must the officer of the watch bear in mind when using ARPA?
Your Answer: (Not answered)
Correct Answer: D (Target tracking may be lost or erroneous due to sea state, target manoeuvres or shadowing, so it cannot be relied upon entirely)
💡 ARPA tracking is affected by sea state, target manoeuvres, shadowing and input data accuracy, and targets may be lost or plotted in error. The officer must cross-check with the raw radar picture and visual look-out.
✗
Question 68. What is the principle for the food ration provided per person in the equipment of a lifeboat?
Your Answer: (Not answered)
Correct Answer: D (Not less than 10 000 kilojoules (about 2400 kilocalories) per person)
💡 Under SOLAS III/34 a lifeboat should carry a food ration of not less than ten thousand kilojoules, about twenty-four hundred kilocalories, for each person the boat is permitted to accommodate, to sustain them while awaiting rescue at sea after abandonment. The ration should be properly packed and within its shelf life.
✗
Question 69. For SOLAS purposes, a passenger ship is one which carries more than how many passengers?
Your Answer: (Not answered)
Correct Answer: A (More than 12)
💡 SOLAS I/2: a passenger ship carries more than 12 passengers; children under one year are not counted.
✗
Question 70. A watertight door open/closed indicator at the central control station shows the wrong state, a door actually open being indicated as closed. The finding is?
Your Answer: (Not answered)
Correct Answer: D (A wrong indication may mislead the bridge as to the subdivision state; a deficiency to be corrected)
💡 The open/closed indicator at the central control station is an important basis for judging the actual state of each watertight door and deciding on closing measures. A wrong indication misleads the bridge as to subdivision integrity and may delay closure in the event of flooding. It is a deficiency to be corrected.
✗
Question 71. What does the Polar Code address regarding ice class of ships in polar waters?
Your Answer: (Not answered)
Correct Answer: A (A ship must have an ice class appropriate to the ice conditions, with action taken if conditions exceed her capability)
💡 The Polar Code requires a ship to have an ice class appropriate to the ice conditions of the intended area, categorised as A, B or C, and to take action such as altering course or stopping if conditions exceed her capability. Blindly entering ice beyond her ability is not acceptable.
✗
Question 72. What is the general requirement of SOLAS Chapter II-1 for machinery and electrical installations?
Your Answer: (Not answered)
Correct Answer: C (They shall ensure the safety of the ship under normal and emergency conditions)
💡 They shall ensure the ship's safety under both normal and emergency conditions.
✗
Question 73. What priority applies to distress communication under SOLAS and the Radio Regulations?
Your Answer: (Not answered)
Correct Answer: D (Distress takes priority over urgency, and urgency over safety)
💡 SOLAS and the Radio Regulations set the order of priority as distress, urgency, safety and other communication. Distress traffic has absolute priority; other traffic must give way and must not occupy distress frequencies for unrelated communication.
✗
Question 74. What must the cargo securing manual contain under SOLAS VI/5 and the CSS Code?
Your Answer: (Not answered)
Correct Answer: C (Securing methods for the various cargo units, specifications of securing equipment and methods of strength verification)
💡 SOLAS VI/5 and the CSS Code require the cargo securing manual to contain the securing methods for the various cargo units, the specification and number of securing devices, methods of strength verification and inspection requirements, for correct securing by the crew.
✗
Question 75. What shall be provided between the bridge and the steering gear compartment?
Your Answer: (Not answered)
Correct Answer: D (Reliable communication such as a sound-powered telephone)
💡 Reliable communication, such as a sound-powered telephone, shall be provided.
✗
Question 76. The inert gas system shall keep the oxygen content in cargo tanks below:
Your Answer: (Not answered)
Correct Answer: A (8%)
💡 Below 8% by volume.
✗
Question 77. Who fixes the minimum safe manning document and how is it used on board?
Your Answer: (Not answered)
Correct Answer: A (settled and issued by the flag administration for the type of ship and the trade)
💡 The figure is the flag's to fix: taking the type of ship, her tonnage and machinery power, the trade she plies and her organisation, with the automation she carries, and following the international guidelines on the subject, the administration settles the least number and the grades needed and sends the document to the ship. She is then manned to it, and those actually on board are not below what it asks; if the two disagree the discrepancy is a deficiency however the work is being done. The port State does not as a rule substitute its own calculation, but where it judges the people on board too few or too untalented for her ordinary and emergency working it may consult the flag. To give the number to the society or to leave it with the company crosses a line: the society surveys hull, machinery and equipment, and what the ship costs to man cannot change the least she needs.
✗
Question 78. What does the Polar Code address regarding equipment for low temperature in polar waters?
Your Answer: (Not answered)
Correct Answer: A (Materials and operating temperatures of essential equipment must suit the low temperatures, preventing brittle fracture and failure)
💡 The Polar Code requires essential equipment, materials and systems of a ship in polar waters to be designed for low temperatures, preventing failure through brittle fracture of steel, increased viscosity of hydraulic oil or reduced battery capacity.
✗
Question 79. What do SOLAS and the ISM Code require in the execution of the planned maintenance programme?
Your Answer: (Not answered)
Correct Answer: B (Carry out the programme and record completion, with reasons given and re-scheduling for items not completed)
💡 ISM Code 10 requires the planned maintenance programme to be carried out with completion and any problems found recorded. Items not completed should have the reason stated, the risk assessed and the work re-scheduled, keeping equipment in good order at all times.
✗
Question 80. The main steering gear shall be capable of putting the rudder from 35° on one side to 35° on the other side, at maximum ahead service speed, within:
Your Answer: (Not answered)
Correct Answer: A (28 seconds)
💡 SOLAS II-1/29 requires the main steering gear to move the rudder from 35° on one side to 35° on the other within 28 seconds at maximum ahead service speed.
✗
Question 81. What is required of the torch carried in survival craft?
Your Answer: (Not answered)
Correct Answer: D (It must be watertight and capable of continuous illumination, provided in the craft for use at night)
💡 SOLAS requires survival craft to carry a watertight torch, normally one per boat or as prescribed, providing light at night after abandonment for checking the condition of the craft, signalling or assisting a person. An ordinary torch is not waterproof and would fail at sea.
✗
Question 82. What is the definition of GMDSS sea area A2?
Your Answer: (Not answered)
Correct Answer: A (An area within MF coast station DSC coverage)
💡 In the GMDSS, sea area A2 is an area within MF coast station continuous digital selective calling coverage, excluding A1. The provision of MF DSC equipment and the corresponding distress alerting means for the trading area is a basic requirement of fitness for that area.
✗
Question 83. What is the relationship between lifejackets and immersion suits in survival craft?
Your Answer: (Not answered)
Correct Answer: A (A lifejacket provides buoyancy while an immersion suit provides thermal protection and buoyancy; they have different functions)
💡 A lifejacket principally provides buoyancy and a face-up attitude in the water, while an immersion suit provides both thermal protection and buoyancy. Their functions differ. In cold waters the ship should carry immersion suits while lifejackets remain required for every person; the two are used together.
✗
Question 84. When a vessel at sea receives a distress alert, what is the master's obligation?
Your Answer: (Not answered)
Correct Answer: A (To proceed as quickly as possible to assist persons in distress, there being an obligation to assist unless doing so would seriously endanger the vessel and persons on board)
💡 Under SOLAS V/33 and the international obligation to render assistance, a vessel in a position to assist, on receiving information about persons in distress, should proceed as quickly as possible to their assistance unless doing so would seriously endanger the vessel and those on board. It should also inform those concerned and maintain communication.
✗
Question 85. The isolating valve on the fire main serving the accommodation side has long been seized and cannot be operated. How should this be judged?
Your Answer: (Not answered)
Correct Answer: D (Fire main isolating valves must be operable at all times; being seized is a deficiency affecting the isolating function)
💡 Isolating valves on the fire main are used to isolate a damaged section of piping so that the rest of the system still receives water. They must be capable of manual operation at all times. Being seized deprives them of their isolating function and is a deficiency affecting the reliability of the firefighting system, which should be rectified.
✗
Question 86. What should be done about failed lighting in an escape route?
Your Answer: (Not answered)
Correct Answer: D (Repair or replace promptly; lighting in escape routes is vital for emergency evacuation)
💡 Lighting in escape routes, including emergency and low level lighting, is essential for evacuation in fire and dense smoke. Failed fittings must be repaired or replaced promptly; their absence greatly increases the difficulty of evacuation and the risk of casualties.
✗
Question 87. From what gross tonnage must ships carry AIS?
Your Answer: (Not answered)
Correct Answer: B (300 GT)
💡 SOLAS V/19: AIS is required for ships of 300 GT and above on international voyages.
✗
Question 88. What is required regarding problems found at a renewal survey before a new certificate is issued?
Your Answer: (Not answered)
Correct Answer: D (All matters affecting issue must be resolved before issue, or accepted by the Administration with conditions recorded)
💡 SOLAS requires matters found at a renewal survey which affect the issue of the certificate to be resolved before issue, or accepted by the Administration with restrictions or additional requirements recorded after assessment. Issuing with the problem outstanding leaves the certificate inconsistent with the actual condition.
✗
Question 89. What additional safety is required when carrying timber deck cargo?
Your Answer: (Not answered)
Correct Answer: A (Enhanced securing, safe access and unobstructed visibility, with attention to deck load and stability)
💡 Timber deck cargo requires enhanced securing with the prescribed methods and attention to the weight gained by water absorption, safe access for the crew and an unobstructed view from the bridge, with deck loading and stability calculated including the effects of water absorption and ice accretion, in accordance with the timber deck cargo requirements of the Load Line Convention.
✗
Question 90. The inert gas system alarms shall operate on:
Your Answer: (Not answered)
Correct Answer: A (high oxygen content, abnormal gas pressure and abnormal water level conditions)
💡 SOLAS II-2/5 requires alarms for high oxygen content, abnormal pressure and abnormal water levels.
✗
Question 91. Which ships shall be fitted with a VDR?
Your Answer: (Not answered)
Correct Answer: A (Passenger ships and cargo ships of 3000 GT and above)
💡 Passenger ships and cargo ships of 3000 GT and above.
✗
Question 92. What is the purpose of the bilge water high level alarm in a machinery space?
Your Answer: (Not answered)
Correct Answer: C (To give an alarm when the bilge level rises abnormally, indicating flooding or failure of the drainage system)
💡 SOLAS II-1 requires a bilge water high level alarm in machinery spaces so that the watchkeeper is warned of abnormal accumulation, indicating flooding or a failure of the drainage system.
✗
Question 93. What authority does the master have in security matters?
Your Answer: (Not answered)
Correct Answer: D (To make security decisions that affect the safety of the ship)
💡 The master may make security decisions affecting the safety of the ship.
✗
Question 94. The ship must clear water from the machinery space in heavy weather. What does SOLAS II-1 require of the bilge system?
Your Answer: (Not answered)
Correct Answer: B (It must be capable of draining any watertight compartment, with at least two power-driven pumps)
💡 SOLAS II-1 requires the bilge system to drain any watertight compartment effectively, with not fewer than two power-driven pumps in the machinery space, one of which may be independently driven.
✗
Question 95. What is the principal cause of deviation error in a magnetic compass?
Your Answer: (Not answered)
Correct Answer: C (The effect of the ship's steel and electrical equipment)
💡 Deviation is caused by the ship's own steel and electrical equipment; deviation tables must be applied.
✗
Question 96. If a DSC alert in sea area A1 receives no response, what does GMDSS procedure require?
Your Answer: (Not answered)
Correct Answer: C (Make a radiotelephony distress call on VHF channel 16 and try other means available)
💡 If a DSC alert is not acknowledged, a radiotelephony distress call should be made on VHF channel 16 or MF 2182 kHz, at the same time or afterwards, and other means such as satellite or HF tried, ensuring the alert is received. Channel 70 must not be used for speech.
✗
Question 97. What shall the Ship Security Plan contain?
Your Answer: (Not answered)
Correct Answer: B (Security organisation, duties, measures and training)
💡 Security organisation, duties, protective measures and training.
✗
Question 98. Which statement about internal auditors under the ISM Code is correct?
Your Answer: (Not answered)
Correct Answer: C (Auditors must be trained and, as far as practicable, independent of the activity being audited)
💡 The ISM Code requires internal audits to be carried out by trained personnel independent of the activity being audited so far as practicable, ensuring objectivity. Self-auditing or untrained auditors do not comply.
✗
Question 99. Means of escape shall:
Your Answer: (Not answered)
Correct Answer: D (be continuous to the embarkation deck or muster station)
💡 SOLAS II-2/13 requires continuous means of escape to the embarkation deck or muster station.
✗
Question 100. What do SOLAS and STCW require regarding the use of the automatic pilot?
Your Answer: (Not answered)
Correct Answer: B (A proper look-out must be kept, and hand steering must be resumed in restricted visibility or dense traffic)
💡 STCW and SOLAS require a proper look-out to be maintained when the automatic pilot is engaged, and hand steering to be resumed in restricted visibility, dense traffic or narrow channels. Automatic steering does not permit relaxation of watchkeeping.