Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. A ship is to load a concentrate liable to liquefy. Under SOLAS VI/1 which two key data must the shipper provide to the master before loading?
Your Answer: (Not answered)
Correct Answer: B (The moisture content and the transportable moisture limit (TML))
💡 SOLAS VI/1 and the IMSBC Code require the moisture content and the TML to be provided before loading. The cargo may be accepted only when the moisture content is below the TML; weight alone gives no indication of liquefaction risk.
✗
Question 2. Cargo tank hatch covers on a tanker shall:
Your Answer: (Not answered)
Correct Answer: C (be kept closed and prevent the escape of vapour when opened)
💡 SOLAS II-2/4 requires cargo tank hatches to be kept closed and to prevent vapour escape.
✗
Question 3. What is the stowage factor used for?
Your Answer: (Not answered)
Correct Answer: C (Estimating the volume the cargo will occupy and judging whether the hold capacity is sufficient)
💡 The stowage factor expresses the volume occupied by unit weight of cargo. It is used to estimate the space required and to judge whether the ship's hold capacity is sufficient for the planned quantity, and is fundamental to stowage calculations.
✗
Question 4. How does the survival craft requirement for a passenger ship differ from that for a cargo ship?
Your Answer: (Not answered)
Correct Answer: A (Each side must accommodate all persons, with additional liferafts for a percentage of the total number of persons)
💡 SOLAS III/21 requires each side of a passenger ship to accommodate all persons on board, with additional liferafts for a percentage of the total number of persons, so that everyone can escape if one side is unavailable.
✗
Question 5. The carriage of dangerous chemicals in bulk shall follow:
Your Answer: (Not answered)
Correct Answer: B (the International Bulk Chemical Code (IBC Code))
💡 SOLAS VII/7: the carriage of dangerous chemicals in bulk shall follow the IBC Code.
✗
Question 6. What minimum duration of air supply does SOLAS II-2/10.1 require for the self-contained compressed air breathing apparatus of a firefighter's outfit?
Your Answer: (Not answered)
Correct Answer: A (30 minutes)
💡 SOLAS II-2/10.1 requires the self-contained breathing apparatus to have a capacity of at least 30 minutes of air. Do not confuse this with the 3-hour electric safety lamp or the 30 m lifeline.
✗
Question 7. Which statement about immersion suits is correct?
Your Answer: (Not answered)
Correct Answer: C (immersion suits reduce body heat loss in cold water)
💡 SOLAS III/32 requires immersion suits for rescue boat crew to reduce body heat loss in cold water.
✗
Question 8. What maintenance does the radar antenna and waveguide require?
Your Answer: (Not answered)
Correct Answer: A (Check that the antenna rotates freely, that the waveguide is not damp or damaged and that the antenna is not obstructed)
💡 Radar requires periodic checking that the antenna turning gear is free, that the waveguide and joints are not damp, damaged or waterlogged and that no new structure such as a mast or antenna obstructs the antenna, with performance checks as prescribed, keeping the detection capability of the radar.
✗
Question 9. What does SOLAS address regarding the protective clothing of a firefighter's outfit?
Your Answer: (Not answered)
Correct Answer: B (It must protect the skin from flame and heat radiation without impeding the wearer's movement)
💡 SOLAS requires the protective clothing of a firefighter's outfit to protect the skin from harm by flame and heat radiation, with an outer surface that is water resistant, and of a size that allows the wearer to move freely.
✗
Question 10. What must the ship security plan contain under the ISPS Code?
Your Answer: (Not answered)
Correct Answer: A (The security organisation and duties, restricted areas, training of personnel, drills and security incident procedures)
💡 ISPS Code Part A/9 requires the ship security plan to cover the security organisation and duties, restricted areas and their control, personnel training and drills, and procedures for security incidents, subject to Administration approval.
✗
Question 11. What guards against fire in a paint locker?
Your Answer: (Not answered)
Correct Answer: C (position, boundaries, extinguishing and detection as the rules require, ventilation independent and clear of ignition sources)
💡 Four things have to hold at once in a space that small: it sits where it is effectively separated from accommodation and cargo, its boundaries are of the class that keeps a fire inside it, extinguishing suited to the hazard is fitted and can be worked from outside, and ventilation carries vapour away without bringing a spark in. Lighting and electrical gear are chosen as for a hazardous area, the entrance carries its warning, and how much is stored and in what containers is limited as well. To stand an extinguisher inside, or to let the crew decide by feel where the danger ends, trades three lines of defence for one spoken judgment. What gets looked at afterwards: whether the enclosure is intact, whether the ventilation works, whether the extinguishing gear is still in date, and whether the paint has been moved somewhere else for convenience.
✗
Question 12. What records of drills and training are required?
Your Answer: (Not answered)
Correct Answer: B (Records of drills and training kept, including dates, content, participants and problems found)
💡 The ISM Code and SOLAS require records of drills and training to be kept, including dates, content, participants, problems found and the improvement action taken, as evidence of the effective operation of the system and a focus of attention at survey and PSC.
✗
Question 13. Under what speed and draught conditions is the capability of the main steering gear determined?
Your Answer: (Not answered)
Correct Answer: D (At maximum service speed and deepest seagoing draught)
💡 SOLAS determines the required capability of the main steering gear at maximum service speed and deepest seagoing draught, which forms the basis of its design.
✗
Question 14. Each person in a lifeboat shall be provided with fresh water of not less than:
Your Answer: (Not answered)
Correct Answer: A (3 litres)
💡 SOLAS III/34 requires not less than 3 litres of fresh water per person in a lifeboat.
✗
Question 15. Under the ISM Code, the master has:
Your Answer: (Not answered)
Correct Answer: A (overriding authority regarding safety and pollution prevention)
💡 SOLAS IX/5: the master has overriding authority regarding safety and pollution prevention and may deviate from the SMS when necessary.
✗
Question 16. What should the crew do after the abandon ship alarm is sounded?
Your Answer: (Not answered)
Correct Answer: A (Act in accordance with the duties in the muster list, taking the designated items to the muster station and awaiting orders)
💡 On the abandon ship alarm the crew acts under the muster list: taking the designated emergency items such as lifejackets, certificates and the log and reporting to the muster station, with the master or the officer in charge deciding whether to abandon and the order of boarding. No one acts independently.
✗
Question 17. How many lifebuoys shall be fitted with self-igniting lights and self-activating smoke signals?
Your Answer: (Not answered)
Correct Answer: D (Two)
💡 At least two, capable of quick release from the bridge.
✗
Question 18. What is the relationship between an extension and a short-term certificate?
Your Answer: (Not answered)
Correct Answer: B (An extension applies where a certificate expires during a voyage; a short-term certificate is issued to enable the ship to reach a port of survey or for another specific purpose)
💡 An extension under SOLAS is a remedy where a certificate expires during a voyage before survey can be carried out, while a short-term certificate is issued for a limited period to enable the ship to reach the port of survey or for another specific purpose. The situations differ and neither may replace the full certificate long term.
✗
Question 19. Emergency lighting shall ensure illumination of:
Your Answer: (Not answered)
Correct Answer: D (escape routes, muster stations, embarkation stations, steering gear and fire pump spaces)
💡 SOLAS II-1/42 requires emergency lighting to cover escape routes, muster and embarkation stations, fire pump and steering gear spaces.
✗
Question 20. What do SOLAS and COLREG emphasise about radar use in restricted visibility?
Your Answer: (Not answered)
Correct Answer: D (Switch on the radar early, use the longer range scales, observe continuously and interpret echoes correctly)
💡 COLREG and SOLAS require the radar to be switched on early in restricted visibility, used on the longer range scales and observed continuously, supplementing visual look-out. Radar must never replace the look-out.
✗
Question 21. What must be recorded in the radio log?
Your Answer: (Not answered)
Correct Answer: B (Distress, urgency and safety traffic, equipment tests and faults and the watchkeeping arrangements)
💡 SOLAS IV/17 requires the radio log to record the content and time of distress, urgency and safety traffic, the daily, weekly and other tests of equipment, faults and repairs and the watchkeeping arrangements, making the management of the equipment and the communication traceable.
✗
Question 22. A PSC inspection found the container holding the fire control plan had taken water and the plan was illegible. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (The plan must be kept in a conspicuously marked weathertight container and remain clear and legible)
💡 SOLAS II-2/15 requires the fire control plan to be permanently stowed in a conspicuously marked weathertight enclosure outside the deckhouse and to remain complete and legible so shore firefighters can use it quickly. Damage to the plan is a deficiency.
✗
Question 23. Which VHF channel is used for distress and safety radiotelephony?
Your Answer: (Not answered)
Correct Answer: A (Channel 16 (156.8 MHz))
💡 VHF channel 16 (156.8 MHz) is for distress and safety radiotelephony. Channel 70 is reserved for DSC calling and must not be used for speech.
✗
Question 24. What does SOLAS address regarding lighting and marking of survival craft stowage?
Your Answer: (Not answered)
Correct Answer: D (Lighting and markings at the stowage positions and embarkation stations, enabling identification and operation at night)
💡 SOLAS requires the stowage positions of survival craft and the embarkation stations to be provided with lighting and clear markings such as signs or reflective tape, enabling persons to find the boarding positions and appliances quickly at night or in dense smoke.
✗
Question 25. What does SOLAS XI-2/8 provide regarding the master's authority and responsibility for security?
Your Answer: (Not answered)
Correct Answer: C (The master has ultimate responsibility for the safety and security of the ship and authority to make necessary decisions)
💡 SOLAS XI-2/8 emphasises that the master has ultimate responsibility for the safety and security of the ship and the authority to take necessary decisions, seeking company or port facility assistance as needed, free of constraint by owner or charterer.
✗
Question 26. Which principle applies to the stowage of survival craft?
Your Answer: (Not answered)
Correct Answer: D (They must be readily available and capable of being launched and boarded rapidly and safely in an emergency)
💡 Under SOLAS III/13 survival craft should be stowed in a position where they are readily available and can be launched and boarded rapidly and safely, protected from the effects of fire and explosion, the arrangement of the craft and their launching and boarding appliances ensuring that in an emergency persons can muster, board and clear quickly.
✗
Question 27. Rules for carrying liquid dangerous goods divide by the form and packing of the cargo. How?
Your Answer: (Not answered)
Correct Answer: A (the International Maritime Dangerous Goods Code for packaged cargo, the Chemical Code for bulk liquid chemicals and the Gas Code for liquefied gas)
💡 The line is whether the goods are packaged: packaged dangerous goods fall under Part A of Chapter VII and the International Maritime Dangerous Goods Code with its emergency response schedules; bulk liquid chemicals under Part B and the IBC Code, BCH for older hulls, which fix the ship type and arrangements; liquefied gas under Part C and the Gas Code. Port and route requirements are additional, not a substitute.
✗
Question 28. What is the hazardous characteristic of a Group A solid bulk cargo under the IMSBC Code?
Your Answer: (Not answered)
Correct Answer: B (It may liquefy if shipped above the TML, causing cargo shift and capsize)
💡 Group A cargoes contain fines and moisture and may liquefy, causing a shift of cargo and loss of stability. The hazard is physical, not chemical.
✗
Question 29. What does SOLAS require for communication between the bridge and machinery space?
Your Answer: (Not answered)
Correct Answer: B (Reliable means must be provided so that the bridge and machinery space can communicate at all times)
💡 SOLAS requires reliable means of communication, such as telegraph or telephone, between the bridge and machinery space at all times. A mobile phone is not an acceptable compliant means.
✗
Question 30. Which is NOT a function of the GMDSS?
Your Answer: (Not answered)
Correct Answer: A (Commercial advertising)
💡 The GMDSS does not provide commercial advertising.
✗
Question 31. An echo sounder shall be fitted on:
Your Answer: (Not answered)
Correct Answer: D (passenger ships on international voyages and cargo ships of 500 GT and above)
💡 SOLAS V/19: passenger ships on international voyages and cargo ships of 500 GT and above shall be fitted with an echo sounder.
✗
Question 32. What should be checked on hatch covers before loading a bulk carrier?
Your Answer: (Not answered)
Correct Answer: C (That the seals, cleats and drain channels are sound, with a hose test to verify watertightness if necessary)
💡 Before loading, the hatch cover seals should be checked for ageing or damage, the cleats for completeness and effectiveness and the drain channels and non-return devices for clearance, with a hose test to verify watertightness where necessary. Hatch cover failure is the principal cause of flooding in bulk carriers.
✗
Question 33. What are the handling requirements when encountering heavy swell and seas?
Your Answer: (Not answered)
Correct Answer: A (Adjust course and speed so that the hull meets the seas at a suitable angle, avoiding a beam sea and direct head seas which cause damage)
💡 In heavy seas and swell the course and speed should be adjusted so the hull meets the seas at a suitable angle, normally obliquely, avoiding a beam sea which causes heavy rolling and cargo shift and direct head seas which cause violent pitching and slamming that damages the hull.
✗
Question 34. How many firefighter's outfits must a cargo ship of 1000 GT and above carry?
Your Answer: (Not answered)
Correct Answer: C (At least two)
💡 SOLAS II-2/10.10 requires at least two firefighter's outfits on cargo ships of 1000 GT and above. Tankers are additionally required to carry extra outfits, normally four.
✗
Question 35. What does SOLAS require for change-over of power supplies for radio equipment?
Your Answer: (Not answered)
Correct Answer: A (Change-over between the main and reserve sources must be completed within the prescribed time, keeping communication unbroken)
💡 SOLAS requires radio equipment to be capable of rapid change-over between the main and reserve sources, so that distress and safety communication is not interrupted for a long period by the change. The change-over arrangement should be tested periodically for reliability.
✗
Question 36. What is the minimum number of lifebuoys for a cargo ship of 90 metres in length?
Your Answer: (Not answered)
Correct Answer: B (Eight)
💡 Under SOLAS III/32 a cargo ship of less than one hundred metres in length carries at least eight lifebuoys, the number increasing with length above that. The lifebuoys and their attachments such as self-igniting lights and lines must also meet the relevant requirements.
✗
Question 37. What action principle do SOLAS and COLREG emphasise once a risk of collision exists?
Your Answer: (Not answered)
Correct Answer: A (Take early and substantial action so as to be readily apparent to the other vessel and avoid a close-quarters situation)
💡 COLREG requires action to be positive, made in ample time and large enough to be readily apparent. Waiting, hesitating or making a succession of small alterations creates confusion and leads to a close-quarters situation.
✗
Question 38. What information must drill records contain under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (The date, the type and scenario of the drill, the craft and equipment used, the persons taking part and any defects found)
💡 SOLAS requires drill records to include the date, the scenario, the craft and equipment used, the persons taking part and any problems found with the action taken, enabling a surveyor to judge whether the drills were genuine and effective.
✗
Question 39. What is required regarding the release of lifeboat gripes in an abandon ship drill?
Your Answer: (Not answered)
Correct Answer: B (Practise releasing the securing arrangements so the crew is familiar with the method and sequence)
💡 An abandon ship drill should include practical release of the lifeboat gripes, limiters and securing arrangements, so that the crew is familiar with the sequence, such as releasing the limiter before the securing, and with the tools. A briefing does not ensure correct operation in an emergency.
✗
Question 40. What special stowage requirements apply to ships loading explosives?
Your Answer: (Not answered)
Correct Answer: B (Keep them away from heat, sources of ignition and accommodation as the IMDG Code requires, with special protection and segregation)
💡 The IMDG Code sets strict requirements for the stowage of class 1 explosives: away from the machinery space, heat and accommodation, segregated from incompatible goods, with special measures for explosion-protected electrical equipment, fire protection and security, and subject to approval by the port authority.
✗
Question 41. The emergency fire pump needs manual priming before it will draw water. What does SOLAS address?
Your Answer: (Not answered)
Correct Answer: B (A deficiency; the emergency fire pump must draw water by itself, and manual priming would delay emergency use)
💡 SOLAS requires the emergency fire pump to be self-priming, or to have a priming arrangement meeting the requirements, so that it draws water without manual priming in an emergency. Needing manual priming would delay the water supply when it matters and is a deficiency.
✗
Question 42. What is the principal characteristic of class 7 dangerous goods?
Your Answer: (Not answered)
Correct Answer: B (Radioactive material, presenting ionising radiation hazards)
💡 Class 7 of the IMDG Code covers radioactive material, whose carriage requires packaging, marking, segregation and personnel exposure to be controlled in accordance with radiation protection requirements. Corrosives are class 8 and miscellaneous dangerous substances class 9.
✗
Question 43. What fire division requirement applies to cargo spaces carrying dangerous goods?
Your Answer: (Not answered)
Correct Answer: B (The prescribed fire division rating, preventing spread of fire to adjacent spaces)
💡 SOLAS requires spaces carrying dangerous goods to be separated from adjacent spaces by class A divisions of the appropriate rating according to position, preventing a dangerous goods fire from spreading rapidly into the machinery space or accommodation.
✗
Question 44. What preparation do SOLAS and BMP require before entering a high risk area?
Your Answer: (Not answered)
Correct Answer: C (Complete a security risk assessment, apply hardening and protective measures, conduct drills and report to the company, with reporting maintained)
💡 Before entering a high risk area a security risk assessment should be completed, protective and hardening measures applied in accordance with BMP, drills held, the company informed and reports made to the relevant bodies as required, so that the ship is prepared if threatened.
✗
Question 45. A ship is found without a permit system or gas testing procedure for entry into enclosed spaces. The finding is?
Your Answer: (Not answered)
Correct Answer: C (A permit and testing procedure for enclosed space entry is required; absence is a serious safety deficiency)
💡 Entry into enclosed spaces requires a permit system with testing for oxygen, flammable gas and toxic gas before entry, ventilation and an attendant, in accordance with procedures. The absence of a permit and testing procedure directly threatens the lives of those entering. It is a serious safety deficiency that may normally lead to detention.
✗
Question 46. What shall embarkation arrangements for survival craft ensure?
Your Answer: (Not answered)
Correct Answer: D (Rapid and orderly boarding and ease of launching)
💡 They shall permit rapid, orderly embarkation and launching.
✗
Question 47. What should be done if the loading instrument of a bulk carrier computes abnormally?
Your Answer: (Not answered)
Correct Answer: D (Stop relying on it and use an approved manual method or shore support, repairing and verifying it as soon as possible)
💡 If a loading instrument computes abnormally, such as results clearly differing from hand calculation or the program reporting errors, reliance on it should cease and an approved manual method or shore support used to complete the strength and stability checks, with the instrument repaired and verified as soon as possible, preventing a wrong result from causing overloading or structural damage.
✗
Question 48. What does SOLAS address regarding the arrangement of ventilation inlets and outlets in machinery spaces?
Your Answer: (Not answered)
Correct Answer: D (They must be arranged to avoid short circuiting and ensure effective air change)
💡 SOLAS requires the inlets and outlets of machinery space ventilation to be arranged to avoid short circuiting and ensure effective air change, preventing excessive temperature or accumulation of flammable gas, both of which affect equipment and safety.
✗
Question 49. What does SOLAS address regarding the arrangement of lubricating oil systems in machinery spaces?
Your Answer: (Not answered)
Correct Answer: C (Piping must be leak-tight and kept away from hot surfaces, with level monitoring of oil tanks)
💡 SOLAS requires lubricating oil piping to be leak-tight and clear of hot surfaces, with level monitoring of the oil tanks. Oil leaking onto a hot surface or a turbine is a common cause of machinery space fires.
✗
Question 50. What training does the ISPS Code require of the ship security officer?
Your Answer: (Not answered)
Correct Answer: B (Security training approved by the Administration, with the necessary knowledge and ability)
💡 ISPS Code Part A/18 requires the ship security officer to have approved security training covering security assessment, implementation of the plan and organisation of drills. Reading the plan or a verbal briefing is not sufficient.
✗
Question 51. How must revisions of system documentation be managed?
Your Answer: (Not answered)
Correct Answer: D (Approved by authorised persons, issued promptly, superseded versions withdrawn and the crew informed)
💡 The ISM Code requires revisions of system documentation to be approved by authorised persons and issued in a controlled way, with the version and effective date shown and superseded versions withdrawn or marked as obsolete, and the crew informed so that they work to the latest version. Uncontrolled amendment leaves different versions in use on board.
✗
Question 52. Apart from when navigation requires, in what state should watertight doors be kept?
Your Answer: (Not answered)
Correct Answer: A (Closed, with their status indicated on the navigation bridge)
💡 SOLAS II-1/15 requires watertight doors to be kept closed except when navigation necessitates opening, with their status shown on the bridge. Being left permanently open is a common PSC deficiency.
✗
Question 53. The muster list is found not updated after crew changes and some duties are vacant. The finding is?
Your Answer: (Not answered)
Correct Answer: A (The muster list must match the crew on board; failure to update is an emergency preparedness deficiency)
💡 The muster list should set out the duties and muster station of each crew member in an emergency and be updated promptly with crew changes so that everyone knows their duty. Failure to update leaves some posts vacant and causes confusion in an emergency. It is a deficiency to be corrected.
✗
Question 54. The engine telegraph shall display orders and replies:
Your Answer: (Not answered)
Correct Answer: C (both on the bridge and in the engine room control position)
💡 SOLAS II-1/31 requires the telegraph to display orders and replies both on the bridge and at the engine control position.
✗
Question 55. What confidentiality applies to the ship security plan?
Your Answer: (Not answered)
Correct Answer: C (Unauthorised access to its contents must be prevented, with the document marked and distribution restricted)
💡 The ISPS Code requires the ship security plan to be a confidential document, marked as such, with restricted distribution and protected against unauthorised access, including electronic versions, preventing the security measures from being circumvented. It may be shown to authorised persons on inspection.
✗
Question 56. The gas regulating valve in a tanker inert gas system is used to:
Your Answer: (Not answered)
Correct Answer: C (regulate the flow of inert gas into cargo tanks and prevent backflow)
💡 SOLAS II-2/5 requires a gas regulating valve to control inert gas flow into cargo tanks and prevent backflow.
✗
Question 57. What checking of rations in lifeboats is required?
Your Answer: (Not answered)
Correct Answer: B (Check the packaging is sound and the rations are within date, replacing them if not)
💡 Lifeboat rations should be checked for sound packaging, free of damage or damp, and for being within their expiry date, with any failing replaced at once. Expired or damp rations provide no nourishment after abandonment and may even cause illness. It is a common deficiency.
✗
Question 58. What are the capacity and pressure requirements of the emergency fire pump?
Your Answer: (Not answered)
Correct Answer: A (Capacity not less than forty per cent of the required total of the main fire pumps and able to maintain the required main pressure in any condition)
💡 Under SOLAS II-2/10 the emergency fire pump should have a capacity not less than forty per cent of the required total of the main fire pumps and be able to maintain the required pressure on the fire main in any condition, including the most unfavourable draught and trim. It should have an independent source of power and self-priming capability.
✗
Question 59. What valves and fittings does SOLAS require on fire pumps?
Your Answer: (Not answered)
Correct Answer: A (A relief valve and pressure gauge on each pump, preventing overpressure damage to the piping)
💡 SOLAS requires a relief valve and pressure gauge on each fire pump, preventing overpressure damage when the discharge valve is closed or the line is blocked, with the gauge enabling the watchkeeper to judge the water supply.
✗
Question 60. In the subdivision of a passenger ship, what does the "subdivision load line" mean?
Your Answer: (Not answered)
Correct Answer: D (An assumed load line used to determine subdivision requirements, not the ship's actual service load line)
💡 The subdivision load line is an assumed load line used in determining subdivision requirements such as bulkhead positions and the subdivision index. It is a different concept from the summer or tropical load lines actually used in service.
✗
Question 61. Which statement about the use of weather routeing is correct?
Your Answer: (Not answered)
Correct Answer: D (The route should be chosen taking account of weather forecasts and the ship's condition, avoiding severe weather and monitoring the passage plan)
💡 Weather routeing should combine professional weather forecasts with the ship's condition, such as stability, cargo and draught, to choose a relatively safe route avoiding typhoons, heavy seas and severe weather, monitoring and adjusting the plan during the voyage. It is an aid, the final navigational decision being the master's responsibility.
✗
Question 62. The crew rest hour records are found clearly inconsistent with the watchkeeping arrangements. The finding is?
Your Answer: (Not answered)
Correct Answer: C (Rest hours must be truthfully recorded and meet the minimum; inconsistency is a violation)
💡 Crew rest hours should meet the minimum requirements and be truthfully and completely recorded. Inconsistency with the watchkeeping arrangements may conceal insufficient rest and endanger the safety of watchkeeping. It is a deficiency against the rest hour rules to be investigated and corrected.
✗
Question 63. What should be done if fuel oil drips onto a hot surface in the machinery space?
Your Answer: (Not answered)
Correct Answer: A (Stop or reduce the load at once, cut off the fuel and cool the area, preventing ignition)
💡 Oil dripping onto a hot surface such as an exhaust pipe or turbocharger may ignite at any moment. The fuel should be cut off at once, the load reduced or the engine stopped and the area cooled. Cleaning up the oil without removing the ignition condition remains highly dangerous.
✗
Question 64. A self-igniting light on a lifebuoy is found inoperative because its battery has failed. The finding is?
Your Answer: (Not answered)
Correct Answer: C (The lifebuoy has lost its night-marking capability, a life-saving equipment deficiency to be replaced)
💡 The self-igniting light is used at night to mark the position of a person overboard and is a key attachment of the lifebuoy. A failed battery makes the lifebuoy unidentifiable at night. This is a functional deficiency of life-saving equipment; the battery or light should be replaced so that it is always ready for use.
✗
Question 65. What readiness of survival craft is required while the ship is in port?
Your Answer: (Not answered)
Correct Answer: C (Kept serviceable and ready; security measures may be applied but must be capable of rapid removal)
💡 While in port survival craft should remain serviceable and ready. Measures against theft may be taken, but they must be capable of being removed quickly to restore use. Locking them up completely or dismantling them would leave persons without the appliances in an emergency.
✗
Question 66. When is a Declaration of Security concluded?
Your Answer: (Not answered)
Correct Answer: D (When security levels differ between ship and port facility, or the interface risk is high)
💡 ISPS Code A/5: a DoS is concluded when levels differ or the security risk at the interface is high.
✗
Question 67. What should be done about failed lighting in an escape route?
Your Answer: (Not answered)
Correct Answer: D (Repair or replace promptly; lighting in escape routes is vital for emergency evacuation)
💡 Lighting in escape routes, including emergency and low level lighting, is essential for evacuation in fire and dense smoke. Failed fittings must be repaired or replaced promptly; their absence greatly increases the difficulty of evacuation and the risk of casualties.
✗
Question 68. What should be noted in steering and handling a lifeboat?
Your Answer: (Not answered)
Correct Answer: A (Familiarity with the rudder and propulsion controls, coordination with those on board and avoiding injury from wave impact)
💡 Handling a lifeboat involves familiarity with the way the rudder and propulsion respond, coordination with the persons on board such as even distribution, holding on and avoiding high speed in heavy seas, preventing persons being thrown about or lost over the side.
✗
Question 69. The length of a fire hose in a machinery space shall generally not exceed:
Your Answer: (Not answered)
Correct Answer: C (15 m)
💡 SOLAS II-2/10 requires hose length in machinery spaces not to exceed 15 m.
✗
Question 70. What is the minimum number of radar transponders (SARTs) for a cargo ship of 500 gross tonnage and above?
Your Answer: (Not answered)
Correct Answer: D (Two, one on each side)
💡 Under SOLAS IV/7 a cargo ship of five hundred gross tonnage and above should carry at least two radar transponders, normally one on each side, so that one can be taken into the survival craft on either side during abandonment. The SART marks the distress position on the radar.
✗
Question 71. What is required for checking the tightness of hatch covers on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Periodic inspection of seals, cleats and drain channels with a hose test to verify weathertightness)
💡 SOLAS requires the hatch covers of a bulk carrier to remain weathertight, with periodic checks of seal ageing, the effectiveness of cleats and the clearance of drain channels, and a hose test where necessary to verify tightness, preventing sea water from entering the holds and damaging structure and cargo.
✗
Question 72. For how long must the GMDSS reserve source of energy supply the radio installation when the main source fails under SOLAS IV/9?
Your Answer: (Not answered)
Correct Answer: C (At least one hour, for both passenger and cargo ships)
💡 SOLAS IV/9 requires the reserve source to supply the radio installation for at least one hour. The 18-hour figure applies to emergency lighting on cargo ships under a different regulation.
✗
Question 73. As a minimum, the flash point of fuel oil (excluding diesel lubricating oil) shall be:
Your Answer: (Not answered)
Correct Answer: B (60°C)
💡 SOLAS II-2/4.2: fuel oil, other than diesel lubricating oil, shall have a flash point of at least 60°C.
✗
Question 74. A cargo ship is 140 m in length with a crew of 20. What capacity must the survival craft on each side provide under SOLAS III/31?
Your Answer: (Not answered)
Correct Answer: D (Each side must accommodate all 20 persons on board)
💡 SOLAS III/31 requires the survival craft on each side of a cargo ship to accommodate all persons on board, so that everyone can escape whichever side is unusable. Counting the total for both sides only is not sufficient.
✗
Question 75. A ship grounded and the investigation found no adequate scale charts of the area on board. What does SOLAS require regarding charts?
Your Answer: (Not answered)
Correct Answer: C (Charts or ENCs of adequate scale covering the intended voyage, kept corrected to the latest information)
💡 SOLAS V/19 requires charts or ENCs of adequate scale covering the whole intended voyage, corrected to the latest information. A general chart or overview display is not sufficient for safe navigation, and the absence of adequate charts is a common cause of grounding.
✗
Question 76. Why can liquefiable bulk cargoes endanger the stability of a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (High moisture content reduces flow resistance, allowing the cargo to liquefy and shift)
💡 Above the flow moisture point the cargo liquefies and shifts, reducing stability.
✗
Question 77. What does an automatic tracking aid do?
Your Answer: (Not answered)
Correct Answer: D (Track targets automatically and assist in assessing collision risk)
💡 It tracks targets and assists in assessing the risk of collision.
✗
Question 78. Before departure, a steering gear test shall be carried out to:
Your Answer: (Not answered)
Correct Answer: A (verify that the main and emergency steering gear are working properly)
💡 SOLAS V/12: a steering gear test shall be carried out before departure to verify that the main and emergency steering gear work properly.
✗
Question 79. Segregation is required when dangerous goods are stowed on board. What is the fundamental purpose?
Your Answer: (Not answered)
Correct Answer: B (To prevent incompatible substances reacting dangerously on contact)
💡 Segregation under SOLAS VII/3 and the IMDG Code prevents incompatible substances from reacting if released, causing fire, explosion or toxic gas. It is not a tallying convenience.
✗
Question 80. An A-60 class division means a division capable of withstanding a standard fire test for:
Your Answer: (Not answered)
Correct Answer: D (60 minutes)
💡 SOLAS II-2/3: an A-60 class division is an A class division capable of withstanding a standard fire test for 60 minutes.
✗
Question 81. Fire hydrant couplings shall:
Your Answer: (Not answered)
Correct Answer: D (be compatible so that hydrants, hoses and nozzles on the same ship are interchangeable)
💡 SOLAS II-2/10: hydrant couplings, hoses and nozzles on the same ship shall be interchangeable.
✗
Question 82. What do SOLAS and the Load Line Convention address regarding the height of air pipe openings on deck?
Your Answer: (Not answered)
Correct Answer: A (The height must be as prescribed, preventing sea water entering the tanks when the deck is swept)
💡 SOLAS and the Load Line Convention require air pipe openings on the freeboard deck and superstructure deck to reach the prescribed height, so that sea water does not readily enter the tanks when the deck is swept or the ship lists, preventing loss of stability.
✗
Question 83. What should be checked on a fire hydrant before use?
Your Answer: (Not answered)
Correct Answer: A (That the valve operates correctly, that the coupling and gasket are sound and that there is no leakage or blockage)
💡 Before use a hydrant should be checked for correct operation of the valve, soundness of the coupling and gasket and correct connection of the hose, with leakage and blockage checked during routine maintenance, ensuring water is available quickly in an emergency.
✗
Question 84. What expansion ratio is generally required for a tanker deck foam system?
Your Answer: (Not answered)
Correct Answer: C (Not exceeding about 12)
💡 The expansion ratio shall generally not exceed about 12.
✗
Question 85. From what tonnage shall speed and distance measuring equipment be fitted?
Your Answer: (Not answered)
Correct Answer: B (500 GT)
💡 500 GT and above.
✗
Question 86. What identification is required for fire main isolation valves?
Your Answer: (Not answered)
Correct Answer: A (Clear marking of their position and direction of operation, enabling prompt and correct action in a fire)
💡 SOLAS requires fire main isolation valves to be clearly marked as to position and direction of operation, so that in an emergency the crew can find them quickly and correctly isolate the section affected. Missing or wrong marking delays firefighting.
✗
Question 87. What is the significance of the marine pollutant mark required by the IMDG Code?
Your Answer: (Not answered)
Correct Answer: A (It identifies a cargo harmful to the environment, requiring stricter pollution prevention measures if it leaks)
💡 The IMDG Code requires the marine pollutant mark on goods meeting the criteria, identifying a cargo that would harm the environment if released. Stricter pollution prevention and response requirements apply to a spill, with reporting as prescribed.
✗
Question 88. What does SOLAS require regarding manoeuvring information?
Your Answer: (Not answered)
Correct Answer: C (Manoeuvring information such as turning circles and stopping distances must be available on board for the master's use)
💡 SOLAS V/19.2.8 requires manoeuvring information such as turning circles, stopping distances and track reach to be on board for the master's use in narrow channels and during berthing. Shore-side retention does not comply.
✗
Question 89. Where shall the emergency fire pump required by SOLAS be located?
Your Answer: (Not answered)
Correct Answer: C (Outside the machinery space)
💡 The emergency fire pump must be located outside the machinery space so that it remains available if that space is on fire.
✗
Question 90. If a survey reveals a major deficiency affecting the validity of a certificate, what may the Administration do?
Your Answer: (Not answered)
Correct Answer: B (Require rectification before the certificate remains valid, and suspend or withdraw the certificate where the deficiency seriously affects safety)
💡 SOLAS I/12 permits the Administration to suspend or withdraw a certificate where the ship or its equipment substantially fails to comply or there is a deficiency seriously affecting safety, until the deficiency is rectified.
✗
Question 91. What do SOLAS and good practice require of the electrical system after a fire?
Your Answer: (Not answered)
Correct Answer: A (Assess the circuits and equipment affected, isolate the faulty part and prioritise supply to emergency and firefighting equipment)
💡 After a fire the circuits affected should be assessed, the faulty part isolated and priority given to supplying emergency lighting, fire pumps and communications, preventing secondary incidents from short circuits or water. Cutting all power would defeat firefighting and evacuation.
✗
Question 92. With regard to openings in the collision bulkhead, which is correct?
Your Answer: (Not answered)
Correct Answer: D (the number of openings shall be reduced to a minimum and no doors or manholes shall be fitted)
💡 SOLAS II-1/12 requires openings in the collision bulkhead to be reduced to a minimum, with no doors, manholes or ventilation ducts.
✗
Question 93. Which is not required when security level 2 is in force?
Your Answer: (Not answered)
Correct Answer: A (Suspending all cargo operations)
💡 Level 2 tightens security and restricts areas but does not require cargo work to stop.
✗
Question 94. How shall watertight doors be operable locally?
Your Answer: (Not answered)
Correct Answer: B (By two persons, one from each side)
💡 They shall be operable locally by two persons, one from each side.
✗
Question 95. What communication is required for key shipboard operations?
Your Answer: (Not answered)
Correct Answer: D (Operations involving several parties must have a designated person in charge, maintained communication and confirmation of key steps)
💡 The ISM Code requires key operations involving several persons or departments, such as cargo work, ballasting, bunkering and hot work, to have a designated person in charge, a communication arrangement including a briefing before starting and confirmation of the key steps, preventing accidents or pollution from a failure of communication.
✗
Question 96. What does SOLAS address regarding stability when carrying timber deck cargo?
Your Answer: (Not answered)
Correct Answer: B (The increase in weight from water absorbed by the timber and ice accretion must be included, with the prescribed stability criteria applied)
💡 SOLAS and the Load Line Convention prescribe stability requirements for ships carrying timber deck cargo, requiring account to be taken of the weight gained from water absorbed, ice accretion and increased windage, assessed against the prescribed criteria, failing which capsize may occur.
✗
Question 97. What attention must be paid to crew mental health and fatigue?
Your Answer: (Not answered)
Correct Answer: C (Attention to the effect of mental state and fatigue on safety, mitigated by sensible work and rest arrangements and communication)
💡 The MLC and STCW require attention to the mental health and fatigue of the crew, addressed by sensible arrangement of work and rest, maintained lines of communication and support and improved living conditions. Fatigue and mental stress affect judgement and performance and are major contributors to accidents.
✗
Question 98. What is the SOLAS concern regarding the protection of stairways in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: A (They must be enclosed by class A or B divisions so they do not become paths for fire and smoke spread)
💡 SOLAS requires stairways in accommodation spaces to be enclosed in class A or B divisions according to their location, because vertical openings create a chimney effect that accelerates the spread of fire and smoke.
✗
Question 99. What must the emergency preparedness procedures contain?
Your Answer: (Not answered)
Correct Answer: A (Identification of the emergencies possible and the alarm and response procedures, duties and external contacts)
💡 The ISM Code requires the emergency preparedness procedures to cover the identification of the emergencies possible, such as fire, flooding, collision, pollution and injury, the alarm and response steps, the duties of each position and shore support and external contacts with search and rescue, the port and the company, with regular drills.
✗
Question 100. What is the core requirement of SOLAS regarding the number and arrangement of bulkheads in a passenger ship?
Your Answer: (Not answered)
Correct Answer: A (The number and position of main bulkheads are determined by the subdivision calculation so that residual stability is adequate after damage)
💡 SOLAS requires the number and position of main bulkheads in a passenger ship to be determined by the subdivision calculation, taking permeability and assumed extents of damage into account, so that the prescribed residual stability and floating position are met. Adding bulkheads at random is not the intent.