Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. What arrangements does SOLAS permit to ensure the availability of radio equipment in sea areas A1 and A2?
Your Answer: (Not answered)
Correct Answer: A (Duplication of equipment, a shore-based maintenance agreement, or at-sea maintenance capability — one of the three)
💡 SOLAS IV/15 allows availability to be ensured by duplication of equipment, a shore-based maintenance contract or at-sea maintenance capability, used singly or in combination.
✗
Question 2. A bypass pipe allowing oily water to be discharged overboard while circumventing the oily water separator is found on board. The finding is?
Your Answer: (Not answered)
Correct Answer: C (An illegal bypass is a serious violation that may lead to detention and administrative penalty)
💡 Oily water must be processed and meet the discharge standard before discharge. Fitting a bypass pipe to discharge overboard while circumventing the separator is a serious violation evading pollution prevention rules. Once found it is not only a detainable deficiency but may also trigger administrative penalty and investigation.
✗
Question 3. What ventilation shall be provided for cargo spaces carrying dangerous goods?
Your Answer: (Not answered)
Correct Answer: B (Independent ventilation controllable according to the nature of the goods)
💡 Independent, controllable ventilation shall be provided.
✗
Question 4. On receiving a request for assistance coordinated by a rescue centre, the master should:
Your Answer: (Not answered)
Correct Answer: B (Proceed to assist so far as safety permits)
💡 The master shall proceed to assist so far as safety of his own ship and crew permit.
✗
Question 5. The recording device of an inert gas system may record:
Your Answer: (Not answered)
Correct Answer: B (oxygen content, gas pressure and time)
💡 SOLAS II-2/5 requires continuous recording of oxygen content, gas pressure and time.
✗
Question 6. What does the propeller speed and direction indicator show?
Your Answer: (Not answered)
Correct Answer: A (The speed and direction of rotation of the propeller)
💡 The speed and direction of rotation of the propeller.
✗
Question 7. Where must the water ingress alarm of a bulk carrier be displayed?
Your Answer: (Not answered)
Correct Answer: B (On the navigation bridge, so the watchkeeper learns at once of flooding in a hold)
💡 SOLAS XII/12 requires the water ingress detection alarm of a bulk carrier to be displayed on the bridge so the officer of the watch can identify the flooded hold and act immediately. Display elsewhere delays response.
✗
Question 8. How must cable penetrations of fire divisions be treated under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (They must be sealed to maintain the original fire and smoke integrity of the division)
💡 SOLAS requires approved penetration seals where cables pass through class A or B divisions, maintaining fire and smoke integrity. Cotton waste or loose packing provides no fire resistance.
✗
Question 9. What should be done if a problem is found with a breathing apparatus face mask?
Your Answer: (Not answered)
Correct Answer: B (Replace it if perished, damaged or not sealing, otherwise it leaks and the apparatus fails)
💡 A face mask that is perished, damaged or not sealing will let the wearer inhale toxic smoke and must be replaced at once. Repair by tape or other temporary means cannot ensure airtightness and is a deficiency affecting the safety of firefighters.
✗
Question 10. What does SOLAS address regarding fire protection on the cargo tank deck of a tanker?
Your Answer: (Not answered)
Correct Answer: B (Measures to prevent sparks and high temperature and to keep firefighting equipment available)
💡 SOLAS requires the deck and openings of a tanker's cargo area to be arranged to prevent sparks, high temperature and impact from creating a source of ignition, with deck foam systems, hydrants and other equipment kept ready for use.
✗
Question 11. What is the cycle for safety management system audits?
Your Answer: (Not answered)
Correct Answer: D (Internal audits normally not exceeding 12 months, annual verification of the DOC and intermediate verification of the SMC)
💡 The ISM Code requires internal audits at intervals not exceeding 12 months, annual verification of the Document of Compliance to keep it valid and intermediate verification of the Safety Management Certificate within its period of validity. Failure to verify in time affects the validity of the certificates.
✗
Question 12. What should be done with a fire hose after use?
Your Answer: (Not answered)
Correct Answer: A (Clean and dry it, then roll and stow it in the proper manner in place, keeping it ready for use)
💡 After use a fire hose should be washed free of oil and salt water, dried and then rolled and stowed in the proper manner in its position, preventing rot and ageing which affect pressure resistance. Stowing it damp or exposing it long term shortens its life.
✗
Question 13. Which system, directly related to fire protection, is required in accommodation and service spaces?
Your Answer: (Not answered)
Correct Answer: B (Fixed fire detection and alarm system)
💡 SOLAS II-2/12 requires fixed fire detection and alarm systems in accommodation and service spaces.
✗
Question 14. Emergency lighting was tested and some survival craft embarkation stations had no lighting. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: C (Embarkation stations, survival craft stowage positions and the water alongside must be lit from the emergency source)
💡 SOLAS requires embarkation stations, survival craft stowage positions and the water alongside to be illuminated from the emergency source of power, ensuring safe abandonment. Torches are not a substitute for fixed emergency lighting.
✗
Question 15. When the ship is taking in water, to control flooding and maintain stability the primary measure is?
Your Answer: (Not answered)
Correct Answer: A (Close the relevant watertight doors and openings in accordance with procedures, locate the flooding and assess stability)
💡 When water is entering, the watertight doors, hatch covers and openings of the affected area should be closed in accordance with procedures to limit the spread to other compartments, while the location and rate of flooding are ascertained, stability and residual buoyancy assessed and those concerned informed. Opening doors to drain may worsen the flooding and must be done with caution.
✗
Question 16. Which equipment shall be provided to maintain an effective watch against collision with a towing operation in restricted visibility?
Your Answer: (Not answered)
Correct Answer: D (Radar and AIS)
💡 Towing operations present a large, dispersed target, so radar and AIS are required in addition to visual watch.
✗
Question 17. Which is the 4 MHz band DSC distress frequency among the HF frequencies?
Your Answer: (Not answered)
Correct Answer: A (4207.5 kHz)
💡 HF DSC distress frequencies are 4207.5, 6312, 8414.5, 12577 and 16804.5 kHz. 2187.5 kHz is an MF frequency and 6312 kHz belongs to the 6 MHz band.
✗
Question 18. Ventilation closing appliances for machinery spaces shall be operable:
Your Answer: (Not answered)
Correct Answer: A (from a readily accessible position outside the machinery space)
💡 SOLAS II-2/8 requires ventilation closing appliances operable from outside the machinery space.
✗
Question 19. When ECDIS is used to satisfy the carriage of charts requirement, the ship must also have:
Your Answer: (Not answered)
Correct Answer: A (Appropriate back-up arrangements)
💡 SOLAS V/19: ECDIS may satisfy chart carriage only if appropriate back-up arrangements are provided.
✗
Question 20. What checks are required for the shafting and propeller?
Your Answer: (Not answered)
Correct Answer: A (Stern tube sealing for oil leakage, the propeller for damage or fouling and the shafting for abnormal vibration)
💡 The stern tube seal should be checked for oil leakage, which affects both lubrication and pollution, the propeller for deformation, damage or fouling by nets and ropes and the shafting and bearings for abnormal vibration and temperature rise, with problems dealt with promptly, preventing loss of propulsion.
✗
Question 21. What material and structural requirements apply to class A divisions?
Your Answer: (Not answered)
Correct Answer: A (They must be of steel or another approved equivalent material, suitably stiffened to maintain structural integrity)
💡 SOLAS requires class A divisions to be of steel or another approved equivalent material, suitably stiffened so that they retain structural integrity and prevent the passage of smoke and flame after the standard fire test.
✗
Question 22. At what stage must the initial survey for statutory certificates be completed?
Your Answer: (Not answered)
Correct Answer: A (Before the ship is put into service)
💡 SOLAS I/7 requires the initial survey to be completed and the certificates obtained before the ship is put into service. Operating without them is a serious breach of the Convention.
✗
Question 23. What is the function of the hydrostatic release unit of an inflatable liferaft?
Your Answer: (Not answered)
Correct Answer: D (To release the raft automatically and allow it to inflate when the ship sinks to a given depth)
💡 The hydrostatic release unit operates at a set depth, cutting the painter and freeing the raft so that it floats free and inflates automatically. It does not add buoyancy nor hold the raft to the ship.
✗
Question 24. What capability must valves on fuel oil tanks have under SOLAS II-2/4.5.3?
Your Answer: (Not answered)
Correct Answer: D (They must be capable of being closed remotely from outside the space in which they are located)
💡 SOLAS requires remote closing of fuel tank valves from outside the space so that the fuel supply can be shut off from a safe position if that space is on fire.
✗
Question 25. The length of a fire hose in a machinery space shall generally not exceed:
Your Answer: (Not answered)
Correct Answer: C (15 m)
💡 SOLAS II-2/10 requires hose length in machinery spaces not to exceed 15 m.
✗
Question 26. When transiting a high-risk piracy area, which of the following is NOT among the measures recommended by Best Management Practices?
Your Answer: (Not answered)
Correct Answer: C (Switching off AIS and automatic identification to avoid being tracked)
💡 Best Management Practices recommend measures such as increasing speed and freeboard, fitting razor wire and physical barriers, providing and drilling a citadel, strengthening lookout and lighting, and reporting as required and reporting pirate activity. AIS should generally remain on, and switching it off may breach the rules and hinder search and rescue, so it is not a recommended measure.
✗
Question 27. What is the basic requirement of a proper look-out during a navigational watch?
Your Answer: (Not answered)
Correct Answer: A (Maintain look-out by sight and hearing as well as by all available means, with the look-out not impeded by other duties)
💡 COLREG and SOLAS require a look-out at all times by sight, hearing and all available means, making a full appraisal of the situation and risk of collision. The look-out must not be given duties that interfere with the watch.
✗
Question 28. The double-side-skin requirement for new bulk carriers does not apply to every bulk carrier. What triggers it?
Your Answer: (Not answered)
Correct Answer: B (new bulk carriers of 150 metres in length and upwards, of single skin construction, intended to carry solid bulk cargo of a density of 1000 kg per cubic metre or greater)
💡 The line is drawn by length and cargo density: new bulk carriers of 150 metres in length and upwards, of single skin construction and intended for solid bulk cargo of a density of 1000 kg per cubic metre or greater, must have double side spaces, so that a breach in the side leaves reserve buoyancy and slows flooding. Carriers of lighter grain and ships under that length fall outside the regulation while still meeting other stability and structural requirements.
✗
Question 29. What is required in managing certificates of competence?
Your Answer: (Not answered)
Correct Answer: A (Ensure they are valid and appropriate to the position held and produce them for port State inspection as required)
💡 The certificates of competence, training certificates and medical certificates of the crew should be kept valid and appropriate to the positions held, kept safely on board and produced at inspection. Expired certificates or a mismatch with the position held is a serious deficiency and may lead to the ship being detained or the crew member being required to be replaced.
✗
Question 30. What do SOLAS and good practice require if remote control of the main engine fails?
Your Answer: (Not answered)
Correct Answer: D (Transfer promptly to local or emergency control and inform the bridge so that appropriate measures can be taken)
💡 If remote control of the main engine fails, the change-over to local or emergency control should be made promptly and the bridge informed at once so that measures such as reducing speed, stopping or anchoring can be taken. In confined waters manoeuvring capability must be restored as quickly as possible.
✗
Question 31. A ship holding a certificate extended under SOLAS I/14:
Your Answer: (Not answered)
Correct Answer: B (may proceed to a port of survey, but shall not carry cargo beyond the specified limitations)
💡 SOLAS I/14: a ship holding an extended certificate may proceed to a port of survey but shall not carry cargo beyond the specified limitations.
✗
Question 32. What reward mechanisms for crew suggestions may be used?
Your Answer: (Not answered)
Correct Answer: D (Rewards and recognition may encourage the crew to propose improvements, driving continual refinement)
💡 The ISM system encourages mechanisms of reward, recognition and inclusion in appraisal for crew who put forward effective improvements or detect significant hazards in time, giving them an incentive to take part in safety management and driving continual enhancement and genuine effectiveness of the system.
✗
Question 33. What is required for stowage and securing of containers?
Your Answer: (Not answered)
Correct Answer: B (Load according to the approved securing plan and stowage plan, securing tier by tier with attention to weight distribution and the order of lashing)
💡 SOLAS and the CSS Code require containers to be loaded in accordance with the approved securing plan and stowage plan, lashed tier by tier with attention to weight distribution, heavier boxes below and avoiding uneven loading, and to the order of lashing, with weights and conditions verified, preventing stack collapse or loss overboard.
✗
Question 34. Who shall approve the Cargo Securing Manual?
Your Answer: (Not answered)
Correct Answer: A (The Administration or its recognized organization)
💡 The Administration or its recognized organization.
✗
Question 35. What fire precautions are required before bunkering?
Your Answer: (Not answered)
Correct Answer: A (Confirm firefighting equipment in place, close relevant openings, clear deck of oil and establish communication with the barge)
💡 Before bunkering, firefighting equipment such as extinguishers, hoses and absorbents should be in place, openings through which oil could enter should be closed and the deck kept free of oil, with communication and an agreed emergency stop arranged with the supplier, preventing overflow and fire.
✗
Question 36. How do hinged and sliding watertight doors differ in use while the ship is at sea?
Your Answer: (Not answered)
Correct Answer: C (the hinged door shut before the ship leaves port and kept shut at sea, while a sliding door permitted to be used may be closed at any moment from the bridge and from either side)
💡 The line is drawn not by which way the door swings or how fast it shuts, but by whether it may be standing open at sea. A hinged door, open, leaves the bulkhead doing nothing, so it is to be shut before the ship parts from the port and kept shut on the voyage. A power slide sits where people must pass, so it is allowed to work at sea where permission covers it, on the terms that it can be closed at any moment from the bridge and from either side of it, that the closing has a sound and a indication, that lamps show where the door stands, that it is tested at intervals and written up, and that a document on board says which doors may be used at sea and when they must be closed, the master seeing it carried out before sailing. Whether the indication, the alarm and the local control work is a common thing to test in an inspection and in a drill; to treat it as long as somebody keeps an eye on it is the opposite of the requirement.
✗
Question 37. Before the release of a fixed gas fire-extinguishing system, an alarm shall be given in order to:
Your Answer: (Not answered)
Correct Answer: A (warn personnel to evacuate the protected space)
💡 SOLAS II-2/10: before the release of a fixed gas fire-extinguishing system an alarm shall be given to warn personnel to evacuate the protected space.
✗
Question 38. What does SOLAS address regarding the helmet and boots of a firefighter's outfit?
Your Answer: (Not answered)
Correct Answer: C (A helmet able to withstand impact and protect the head, and boots resistant to puncture and electrically insulating)
💡 SOLAS requires a rigid helmet able to withstand impact with a face shield, and boots resistant to puncture and electrically insulating. An ordinary safety helmet and rubber boots do not meet the requirements for firefighting.
✗
Question 39. What does SOLAS address regarding the subdivision of bilge drainage arrangements?
Your Answer: (Not answered)
Correct Answer: A (The bilge system must be arranged in sections so that water in any compartment can be drained independently)
💡 SOLAS requires the bilge system to be arranged in sections with independent suctions, so that water in any compartment can be drained on its own without affecting others, and the location of flooding can be identified. A single central suction does not meet the requirement.
✗
Question 40. A ship's radio reserve source is a battery. For how long must its capacity sustain operation under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (At least one hour of communication, including distress alerting capability)
💡 SOLAS IV/9 requires the reserve source to sustain at least one hour of essential communication including distress alerting after the main source fails. Where the emergency source also supplies the radio installation, it may be taken into account.
✗
Question 41. The ship security alert system (SSAS) fails its test and cannot transmit an alert to the Administration. The finding is?
Your Answer: (Not answered)
Correct Answer: B (SSAS failure affects the ability to call for help when attacked, a security equipment deficiency to be corrected)
💡 The ship security alert system should be able to transmit an alert to the shore receiving point designated by the Administration when the ship is under a security threat and should be available at all times. A failed test shows it cannot fulfil its function at the critical moment. It is a security equipment deficiency to be corrected.
✗
Question 42. With regard to openings in the collision bulkhead, which is correct?
Your Answer: (Not answered)
Correct Answer: D (the number of openings shall be reduced to a minimum and no doors or manholes shall be fitted)
💡 SOLAS II-1/12 requires openings in the collision bulkhead to be reduced to a minimum, with no doors, manholes or ventilation ducts.
✗
Question 43. In radiocommunication, what is the priority of distress communication?
Your Answer: (Not answered)
Correct Answer: B (It has the highest priority above all other communication, which must give way to it)
💡 Under the Radio Regulations and the GMDSS distress communication has the highest priority and all other communication must give way and keep silence while it is in progress. A ship receiving a distress alert or distress traffic must not use the distress frequencies for non-distress communication.
✗
Question 44. How often must the radio reserve source of energy (batteries) be tested?
Your Answer: (Not answered)
Correct Answer: C (Weekly)
💡 SOLAS IV/13 and the associated performance standards require the reserve batteries to be checked and tested weekly to confirm capacity and condition of connections.
✗
Question 45. A watertight door open/closed indicator at the central control station shows the wrong state, a door actually open being indicated as closed. The finding is?
Your Answer: (Not answered)
Correct Answer: D (A wrong indication may mislead the bridge as to the subdivision state; a deficiency to be corrected)
💡 The open/closed indicator at the central control station is an important basis for judging the actual state of each watertight door and deciding on closing measures. A wrong indication misleads the bridge as to subdivision integrity and may delay closure in the event of flooding. It is a deficiency to be corrected.
✗
Question 46. Which systems shall be used to receive navigational warnings?
Your Answer: (Not answered)
Correct Answer: C (Maritime safety information systems such as NAVTEX and SafetyNET)
💡 Systems such as NAVTEX and SafetyNET.
✗
Question 47. What cooperation with an external audit is required?
Your Answer: (Not answered)
Correct Answer: A (Provide documentation, records and the actual condition truthfully, arrange personnel to assist and explain the operation honestly, without concealing or falsifying)
💡 An external audit requires the system documentation, records and the actual condition of the ship to be provided truthfully, personnel arranged to assist and the operation explained honestly. Concealing problems, making up records at short notice or obstructing the audit is a serious breach and may lead to suspension or withdrawal of certificates.
✗
Question 48. The engine telegraph shall display orders and replies:
Your Answer: (Not answered)
Correct Answer: C (both on the bridge and in the engine room control position)
💡 SOLAS II-1/31 requires the telegraph to display orders and replies both on the bridge and at the engine control position.
✗
Question 49. The loading of solid bulk cargoes shall:
Your Answer: (Not answered)
Correct Answer: A (comply with the IMSBC Code, taking account of cargo properties)
💡 SOLAS VI/6 requires loading of solid bulk cargoes in accordance with the IMSBC Code.
✗
Question 50. What are the key points in using a portable extinguisher?
Your Answer: (Not answered)
Correct Answer: D (Pull the pin, aim the nozzle at the base of the fire and sweep while pressing the lever)
💡 Using a portable extinguisher involves pulling the pin, holding the nozzle and aiming at the base of the fire, that is the burning surface, then sweeping while pressing the lever. Aiming at the top of the flames is ineffective, and the position should allow a line of retreat.
✗
Question 51. What fire precautions apply to tank cleaning on a tanker?
Your Answer: (Not answered)
Correct Answer: C (Follow the approved procedure, controlling static electricity, maintaining inerting and monitoring tank gas and oxygen content)
💡 Crude oil washing or water washing should follow the approved procedure, controlling jet velocity and the generation of static electricity by limiting nozzle pressure and maintaining earthing, keeping the tanks inerted and monitoring hydrocarbon concentration and oxygen content, preventing static discharge from igniting vapour.
✗
Question 52. What does SOLAS address regarding lighting and marking of survival craft stowage?
Your Answer: (Not answered)
Correct Answer: D (Lighting and markings at the stowage positions and embarkation stations, enabling identification and operation at night)
💡 SOLAS requires the stowage positions of survival craft and the embarkation stations to be provided with lighting and clear markings such as signs or reflective tape, enabling persons to find the boarding positions and appliances quickly at night or in dense smoke.
✗
Question 53. What is the relationship between an extension and a short-term certificate?
Your Answer: (Not answered)
Correct Answer: B (An extension applies where a certificate expires during a voyage; a short-term certificate is issued to enable the ship to reach a port of survey or for another specific purpose)
💡 An extension under SOLAS is a remedy where a certificate expires during a voyage before survey can be carried out, while a short-term certificate is issued for a limited period to enable the ship to reach the port of survey or for another specific purpose. The situations differ and neither may replace the full certificate long term.
✗
Question 54. What is the time requirement for launching and recovering a rescue boat under SOLAS III?
Your Answer: (Not answered)
Correct Answer: B (Recovery must be possible within 5 minutes in moderate sea conditions)
💡 SOLAS III requires a rescue boat to be capable of being launched and recovered within 5 minutes in moderate sea conditions, so that a person in the water can be recovered quickly.
✗
Question 55. What does SOLAS address regarding the construction of side doors and cargo doors in the shell?
Your Answer: (Not answered)
Correct Answer: C (They must be of strength equivalent to the adjacent hull with reliable closing appliances, included in survey and records)
💡 SOLAS requires shell doors and cargo doors in a cargo ship to have strength and watertightness equivalent to the adjacent hull, with reliable closing appliances, and to be included in periodic survey and maintenance records, since such openings are a high risk point for flooding.
✗
Question 56. What is the basic principle of handling when a tropical cyclone is encountered?
Your Answer: (Not answered)
Correct Answer: B (deciding which semicircle the ship is in and working to stay far from the centre with room enough)
💡 There is one principle: do not meet the centre. The first thing is where the ship lies in the system - the way the wind turns and how fast the pressure is falling, the sequence of weather and the sea, with the forecast and any advice from the routing service - deciding which side of the track she is on, since on the right in the northern hemisphere the spin of the wind adds to the motion of the system and lays the ship across the path the centre is taking, while on the left a course and a speed can be found that walk her away. Distance from the centre matters more than shelter from a strong wind, the region near it with its falling barometer and confused swell being what no ship should be asked to stand. To stop in deep water is not safety: the ship drifts with the wind into the very path she wished to avoid, and the speed that could have bought position is given up. Held in the navigable semicircle the aim is to keep the centre on a stated quarter and run out; found in the dangerous one the ship must try to pass round into the other, not across the track. Where to turn depends on the force, the water there is and the ship.
✗
Question 57. When a lifeboat also serves as a rescue boat, what conditions must it satisfy under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (It must meet the requirements for a rescue boat in respect of rapid launching and recovery, speed and manoeuvrability)
💡 SOLAS requires a lifeboat serving as a rescue boat to meet all the rescue boat requirements for rapid launching and recovery, minimum speed and manoeuvrability. Labelling or adding equipment alone is not sufficient.
✗
Question 58. What must be done on receiving maritime safety information at sea?
Your Answer: (Not answered)
Correct Answer: B (Assess its effect on the voyage promptly, adjusting course or speed and informing those concerned as necessary)
💡 On receiving navigational warnings or weather warnings, the officer of the watch should promptly assess their effect on the route, speed and operations, adjusting the plan and informing the master and others as necessary. Recording alone is not sufficient.
✗
Question 59. What is the purpose of a compass corrector on board?
Your Answer: (Not answered)
Correct Answer: C (Eliminating residual deviation of the magnetic compass)
💡 A compass corrector compensates for residual deviation caused by the ship's magnetic field.
✗
Question 60. What does SOLAS V require of the master when heavy weather is encountered at sea?
Your Answer: (Not answered)
Correct Answer: D (To take appropriate measures to safeguard the ship, altering course or speed if necessary, and to report to the company)
💡 SOLAS V/33 places responsibility for the safety of the ship and persons on board on the master, who must take measures such as sheltering, altering course or reducing speed, and must report under the SMS.
✗
Question 61. Why does SOLAS require firefighter's outfits to be stowed in more than one location?
Your Answer: (Not answered)
Correct Answer: A (To prevent a fire in one place from making all the outfits unavailable, so they are distributed)
💡 SOLAS requires firefighter's outfits to be stowed in two or more positions because, if they were all in one place, a fire there would make every outfit unavailable and firefighting and rescue could not proceed.
✗
Question 62. On the night watch the OOW must keep track of every watertight door. Under SOLAS chapter II-1, which requirement for power-operated sliding watertight doors is stated correctly?
Your Answer: (Not answered)
Correct Answer: A (the bridge shall carry indicators showing each door open or closed, closing normally taking between 20 and 40 seconds with the alarm sounding throughout)
💡 Bridge indicators showing each door individually exist so the OOW can confirm watertight integrity at any moment, not only after flooding; the 20-40 second closing time and continuous alarm give persons below the door time to clear. Verbal relaying or control-room-only indication is a substitute the regulation does not accept.
✗
Question 63. Navigation equipment shall be capable of operating:
Your Answer: (Not answered)
Correct Answer: C (with an independent supply if the main and emergency sources fail)
💡 SOLAS V/19: navigation equipment shall have an independent supply where the main and emergency sources of electrical power fail.
✗
Question 64. After failure of the main source of power, within what period must the emergency generator take over automatically?
Your Answer: (Not answered)
Correct Answer: A (Within 45 seconds)
💡 SOLAS II-1/41 requires the emergency generator to start automatically and connect to the emergency switchboard within 45 seconds. Fifteen seconds applies to the transitional reserve source of power (batteries).
✗
Question 65. What should be done if abnormal heel develops during cargo operations?
Your Answer: (Not answered)
Correct Answer: D (Stop work at once, establish the cause such as cargo shift, flooding or uneven ballast, and then decide the course of action)
💡 If abnormal heel develops during cargo work, operations should stop immediately and the cause established, whether cargo has shifted, a compartment is flooding or the ballast is uneven, with stability and structural condition assessed before deciding what to do. Continuing could allow the heel to increase rapidly and cause capsize.
✗
Question 66. While a pilot is on board, the officer of the watch should:
Your Answer: (Not answered)
Correct Answer: D (Maintain a proper look-out and monitor the pilot's actions)
💡 The OOW remains responsible and must monitor the pilot and keep a proper look-out.
✗
Question 67. Besides the ship, where else shall life-saving appliances be provided?
Your Answer: (Not answered)
Correct Answer: A (One full set at the shore establishment)
💡 A full set shall also be kept at the shore establishment.
✗
Question 68. By when must a newly joined crew member complete familiarisation with his duties under the ISM Code?
Your Answer: (Not answered)
Correct Answer: C (Before taking up his duties)
💡 ISM Code 6.5 requires the company to ensure that newly assigned personnel are familiar with their duties before they take them up, not afterwards.
✗
Question 69. What does the ISM Code require regarding training of personnel on board?
Your Answer: (Not answered)
Correct Answer: C (Crew must be trained and have the knowledge and skills needed for their duties, with records kept)
💡 ISM Code 6 requires the company to establish training procedures ensuring that personnel are trained and have the knowledge and skills needed for their duties, with records kept. Training must be completed before taking up duties, not afterwards.
✗
Question 70. What does SOLAS require regarding a look-out when the ship is under way?
Your Answer: (Not answered)
Correct Answer: A (A look-out must be posted when conditions require it, to assist the officer in maintaining a proper look-out)
💡 SOLAS and COLREG require a look-out to be posted when conditions demand it, such as in restricted visibility, dense traffic or narrow channels. The look-out's sole duty is to keep watch and report, without other tasks such as steering.
✗
Question 71. For a passenger ship, within what time after a loss of propulsion shall the ship be able to restore propulsion?
Your Answer: (Not answered)
Correct Answer: A (30 minutes)
💡 SOLAS II-1/26: passenger ships shall restore propulsion within 30 minutes of a dead-ship condition.
✗
Question 72. What does the annual inspection of an extinguisher include?
Your Answer: (Not answered)
Correct Answer: D (Checking pressure or weight, the seal and pin, the hose and nozzle and corrosion of the body, with records kept)
💡 SOLAS and good practice require the annual inspection of an extinguisher to cover internal pressure or weight, detecting leakage, the condition of the pin and seal, the freedom of the hose and nozzle and corrosion or damage of the body, with records and marking.
✗
Question 73. What does SOLAS require of the water ingress detection and alarm system on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: B (Detection in cargo holds, ballast tanks and dry spaces, with an audible and visual alarm on the bridge)
💡 SOLAS XII/12 requires a bulk carrier to have water ingress detection in cargo holds, ballast tanks and dry spaces, with an audible and visual alarm on the bridge, enabling the watchkeeper to detect flooding promptly and act.
✗
Question 74. What are the restrictions on non-protected portable equipment in tanker cargo tanks?
Your Answer: (Not answered)
Correct Answer: D (Equipment such as ordinary torches or non-protected radios may not be used where vapour may accumulate)
💡 Vapour may accumulate in the cargo tanks, pump room and adjacent spaces of a tanker, so equipment that may produce a spark, such as ordinary torches, non-protected radios, power tools and camera flashes, is prohibited. Intrinsically safe or explosion-protected equipment must be used.
✗
Question 75. A lifeboat shall be provided with at least how many hand flares?
Your Answer: (Not answered)
Correct Answer: B (6)
💡 SOLAS III/34 requires at least six hand flares in a lifeboat.
✗
Question 76. What should the ventilation measures meet before entering an enclosed space?
Your Answer: (Not answered)
Correct Answer: A (Adequate ventilation should be provided and the atmosphere tested as satisfactory before entry, with continuous ventilation and an attendant during the work)
💡 Before entering an enclosed space adequate ventilation should be provided and the atmosphere tested for oxygen, flammable gas and toxic gas and confirmed satisfactory, and during entry ventilation should be continuous, an attendant stationed at the entrance and communication maintained. Entry without ventilation, testing or an attendant is prohibited.
✗
Question 77. What is sea area A2?
Your Answer: (Not answered)
Correct Answer: D (An area within MF coast station coverage, excluding A1)
💡 Within MF coast station coverage with DSC, excluding A1.
✗
Question 78. What do SOLAS and the IMDG Code require if dangerous goods leak on board?
Your Answer: (Not answered)
Correct Answer: D (Follow the measures in the EmS Guide for the relevant UN number, preventing ignition and personnel exposure)
💡 SOLAS VII requires the measures in the EmS Guide for the UN number concerned to be followed, including personal protection, ventilation, collection and isolation. Some substances react with water, so washing with water is not always appropriate; the Guide must be followed.
✗
Question 79. What do SOLAS and the IBC Code address regarding the operation of the inert gas system?
Your Answer: (Not answered)
Correct Answer: D (It must remain in operation with tank pressure and oxygen content monitored during cargo, ballast and tank cleaning operations)
💡 SOLAS and the IBC Code require the inert gas system to remain in operation during cargo handling, ballasting and tank washing, with the oxygen content and pressure of each tank monitored continuously. If limits are exceeded, operations must stop to avoid the risk of explosion.
✗
Question 80. What does the Polar Code address regarding ice class of ships in polar waters?
Your Answer: (Not answered)
Correct Answer: A (A ship must have an ice class appropriate to the ice conditions, with action taken if conditions exceed her capability)
💡 The Polar Code requires a ship to have an ice class appropriate to the ice conditions of the intended area, categorised as A, B or C, and to take action such as altering course or stopping if conditions exceed her capability. Blindly entering ice beyond her ability is not acceptable.
✗
Question 81. The navigation lights are found not to meet the required position, colour or arc of visibility. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Non-compliant navigation lights affect the ability of other ships to judge the situation, a deficiency to be corrected)
💡 The position, colour and arc of visibility of the navigation lights, such as masthead, sidelights and stern light, must meet the requirements so that other ships can judge the heading and movement of the vessel from the correct bearing and distance. Non-compliance may lead to misjudgement and increased risk of collision. It is a deficiency to be corrected.
✗
Question 82. How should the hands-on ability of the crew be assessed?
Your Answer: (Not answered)
Correct Answer: D (Assessed through practical drills on critical equipment, with training strengthened where it is weak)
💡 The ISM Code and STCW require the practical ability of the crew on critical equipment to be assessed through drills, such as donning breathing apparatus, using extinguishers and hoses, preparing to launch a lifeboat, emergency steering and damage control operations, with training strengthened where skill is lacking, so that the ability is genuinely usable.
✗
Question 83. What emergency supplies are required in polar waters?
Your Answer: (Not answered)
Correct Answer: D (Sufficient warm clothing, emergency food and water, heating means and emergency lighting)
💡 The Polar Code requires emergency supplies suited to the polar environment: ample warm clothing and thermal protection, emergency food and water, means of heating such as a spare heater, emergency lighting and communication equipment, in view of the long search and rescue response times.
✗
Question 84. The stability information supplied to the master shall:
Your Answer: (Not answered)
Correct Answer: D (be approved and include stability for various loading conditions)
💡 SOLAS II-1/5 requires approved stability information covering various loading conditions.
✗
Question 85. Which account of the segregation of dangerous goods holds up?
Your Answer: (Not answered)
Correct Answer: A (keeping the goods apart as the IMDG Code requires, from other dangerous goods, from foodstuffs and from accommodation)
💡 Segregation pulls chemically unsuitable substances apart horizontally and vertically to the level the Code gives, so that a leak does not bring them into reaction, foul foodstuffs or reach accommodation; on the stowage plan that becomes the choice of hold and tier, the distance from heat and from living spaces, and the number each term - away from, separated from - calls for. It is not advice and two parties cannot agree it away: the levels already reckon the consequence of a leak, and an agreed change of position may only be made within what the level demands. One hold with two tiers commonly does not satisfy it, some combinations calling for a different hold or separation by a complete deck. The requirement belongs in the plan prepared before loading and is re-worked whenever the stow changes.
✗
Question 86. Under the ISM Code, non-conformities shall be:
Your Answer: (Not answered)
Correct Answer: B (analysed, corrected and prevented from recurring)
💡 SOLAS IX/9 (ISM) requires non-conformities to be analysed, corrected and prevented from recurring.
✗
Question 87. What securing is required for vehicles carried as ro-ro cargo?
Your Answer: (Not answered)
Correct Answer: A (Secure using the lashings or chains specified in the securing manual, confirming brake and gear status)
💡 SOLAS and the CSS Code require ro-ro cargo to be secured with the lashing straps, chains or dedicated devices specified in the securing manual, with the vehicle confirmed braked and in a suitable gear and its fuel and battery condition acceptable, preventing movement and collision during the voyage.
✗
Question 88. Who provides long-range identification and tracking information?
Your Answer: (Not answered)
Correct Answer: D (The flag State)
💡 The flag State.
✗
Question 89. What is required regarding medication affecting the ability to keep watch?
Your Answer: (Not answered)
Correct Answer: A (Crew taking medication that may impair judgement or reaction must not keep watch, with the company managing the risk)
💡 Medication that may cause drowsiness, reduced attention or slow reactions, such as some cold remedies, sedatives and antihistamines, impairs the ability to keep watch. Crew should report it and avoid standing watch or be relieved, and the company should have management requirements and a means for seafarers to declare their condition.
✗
Question 90. Who is responsible for the maintenance of life-saving appliances under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (A suitably qualified person on board for routine maintenance, with complex servicing by an approved service station)
💡 SOLAS requires a suitably qualified person on board to be responsible for routine inspection and maintenance, with complex servicing of inflatable liferafts, launching appliances and similar items carried out by an approved service station.
✗
Question 91. What are the stowage and testing requirements for the emergency towing arrangement?
Your Answer: (Not answered)
Correct Answer: C (Stowed so as to be readily available and inspected at regular intervals)
💡 SOLAS requires the emergency towing arrangement to be stowed where it can be rapidly deployed and to be inspected regularly, so that it works in an emergency. Long-term stowage in a hold or neglect of inspection may delay assistance.
✗
Question 92. For portable fire extinguishers, the most important check item is:
Your Answer: (Not answered)
Correct Answer: D (pressure indication and seal integrity)
💡 SOLAS II-2/10 requires extinguishers to be kept ready for use; checks include pressure indication and seal integrity.
✗
Question 93. What is the basic requirement of SOLAS for protection against electric shock?
Your Answer: (Not answered)
Correct Answer: A (Live parts must be protected, and safety voltage or isolation used in hazardous locations)
💡 SOLAS requires exposed live parts to be protected and safety voltage or isolation and residual current protection to be used in damp or metal-enclosed locations, reducing the risk of electric shock.
✗
Question 94. What do SOLAS and the IMSBC Code address regarding trimming of solid bulk cargo?
Your Answer: (Not answered)
Correct Answer: B (Cargo should be trimmed to reduce the risk of shifting and heeling, with special trimming required for certain cargoes)
💡 SOLAS and the IMSBC Code require trimming according to the nature of the cargo, distributing it evenly and reducing shifting and heeling during the voyage. Certain cargoes such as those liable to liquefy have specific trimming requirements, and failure to trim can lead to cargo shift and capsize.
✗
Question 95. What is the core issue addressed by the International Grain Code in relation to stability?
Your Answer: (Not answered)
Correct Answer: D (The effect on stability of heeling moments arising from grain shifting and settling during the voyage)
💡 The International Grain Code requires the heeling moments from grain shifting and settling to be calculated and the residual stability verified for the prescribed angles of heel, preventing excessive list from grain shift.
✗
Question 96. A ship carrying dangerous goods is asked by PSCOs to produce documentation. What does SOLAS VII/4 require on board?
Your Answer: (Not answered)
Correct Answer: B (A dangerous goods manifest or stowage plan showing the location of each class of goods)
💡 SOLAS VII/4 requires a manifest or stowage plan listing the dangerous goods and their location on board so they can be found quickly in an emergency. An ordinary cargo manifest is not a substitute.
✗
Question 97. The reserve source of energy for radio installations shall be capable of operating for at least:
Your Answer: (Not answered)
Correct Answer: A (6 hours)
💡 SOLAS IV/13: the reserve source of energy shall be capable of operating the radio installation for at least 6 hours.
✗
Question 98. When navigating in or near an area of restricted visibility, which action is required?
Your Answer: (Not answered)
Correct Answer: A (Proceed at a safe speed, have engines ready, sound fog signals, stop if necessary and take avoiding action in ample time)
💡 Under the collision regulations a vessel navigating in or near an area of restricted visibility should proceed at a safe speed, have engines ready for immediate manoeuvre, sound fog signals, stop if necessary and take avoiding action in ample time for detected targets. On hearing a fog signal apparently forward of the beam, speed should be reduced or the vessel stopped.
✗
Question 99. A radar transponder (SART) shall operate in the frequency band:
Your Answer: (Not answered)
Correct Answer: D (9 GHz (X-band))
💡 SOLAS IV/7: a SART operates in the 9 GHz (X-band) band so that it can be displayed on a ship's radar.
✗
Question 100. What do SOLAS and STCW require regarding the use of the automatic pilot?
Your Answer: (Not answered)
Correct Answer: B (A proper look-out must be kept, and hand steering must be resumed in restricted visibility or dense traffic)
💡 STCW and SOLAS require a proper look-out to be maintained when the automatic pilot is engaged, and hand steering to be resumed in restricted visibility, dense traffic or narrow channels. Automatic steering does not permit relaxation of watchkeeping.