Question 1. What does SOLAS V require regarding danger messages?
Your Answer: (Not answered)
Correct Answer: A (A danger message must be sent immediately on encountering a danger to navigation, with notification to the competent authority)
💡 SOLAS V/31 requires the master to send a danger message immediately on encountering a danger such as floating objects, uncharted obstructions or severe ice, and to notify the competent authority so warnings can be issued.
✗
Question 2. What shall the Polar Water Operational Manual contain?
Your Answer: (Not answered)
Correct Answer: B (Operational procedures and limitations for polar waters)
💡 Operational procedures and limitations for polar waters.
✗
Question 3. What shall embarkation arrangements for survival craft ensure?
Your Answer: (Not answered)
Correct Answer: D (Rapid and orderly boarding and ease of launching)
💡 They shall permit rapid, orderly embarkation and launching.
✗
Question 4. Where the main steering gear comprises two or more identical power units, what does SOLAS require if one fails?
Your Answer: (Not answered)
Correct Answer: C (The remaining units must continue to steer the ship and change-over must be effected quickly)
💡 SOLAS requires that, with multiple power units, the remaining unit or units continue to steer the ship and that change-over is effected within the prescribed time, so control is never lost.
✗
Question 5. Under SOLAS I/2, from what point does a ship under construction become subject to the Convention?
Your Answer: (Not answered)
Correct Answer: C (From the date the keel is laid or the ship is at a similar stage of construction)
💡 SOLAS uses keel laying, or a comparable identifiable stage of construction, as the date determining which standards apply to a new ship. Launching and delivery are not the reference points.
✗
Question 6. What is required when an electronic aid such as GPS behaves abnormally?
Your Answer: (Not answered)
Correct Answer: B (Recognise the abnormality and switch promptly to other means of position fixing, recording and reporting the situation)
💡 Abnormal behaviour of GPS, such as a jump in position, loss of signal or an integrity alarm, should be recognised with prompt recourse to radar, visual fixing and other means for cross-checking, and the matter recorded and reported. In confined waters this avoids grounding from an error in a single aid.
✗
Question 7. What does SOLAS address regarding fixed fire detection in ro-ro spaces?
Your Answer: (Not answered)
Correct Answer: B (A fixed fire detection and fire alarm system capable of detecting a fire in the vehicle space promptly)
💡 SOLAS requires ro-ro and vehicle spaces to have a fixed fire detection and fire alarm system. Because these spaces are large and vehicles carry fuel, fire spreads rapidly, and periodic rounds alone would not detect it in time.
✗
Question 8. What fire detection is required in spaces carrying dangerous goods?
Your Answer: (Not answered)
Correct Answer: C (Detection suited to the cargo, with gas detection for certain cargoes)
💡 SOLAS and the IMDG Code require spaces carrying dangerous goods to have detection suited to the cargo, such as smoke, heat or gas detection, with gas detection and alarm where flammable gas may be released, so that an incipient fire or a leak is detected promptly.
✗
Question 9. What does the daily check of radio equipment require under SOLAS IV/13 and the performance standards?
Your Answer: (Not answered)
Correct Answer: D (Daily checks of the equipment with a record of whether it functions correctly)
💡 SOLAS IV/13 and the GMDSS performance standards require daily checks of radio equipment, such as DSC self-tests and battery voltage, with a record kept, keeping the equipment in a state of readiness.
✗
Question 10. A cargo ship completed its renewal survey in June 2020. Under SOLAS I/10, when must the subsequent annual surveys be held?
Your Answer: (Not answered)
Correct Answer: D (Every 12 months, within three months before or after the anniversary date)
💡 SOLAS I/10 requires annual surveys every 12 months, normally within a window of three months before or after the anniversary date.
✗
Question 11. Regarding fuel oil in the Antarctic area, which is correct?
Your Answer: (Not answered)
Correct Answer: C (The use and carriage of heavy fuel oil are prohibited)
💡 MARPOL/SOLAS prohibit the use and carriage of heavy fuel oil in the Antarctic area.
✗
Question 12. Ships shall be provided with heading indication by means of:
Your Answer: (Not answered)
Correct Answer: D (a gyro-compass or magnetic compass providing heading indication on the bridge)
💡 SOLAS V/19 requires heading indication equipment providing heading to the bridge.
✗
Question 13. What is the definition of GMDSS sea area A2?
Your Answer: (Not answered)
Correct Answer: A (An area within MF coast station DSC coverage)
💡 In the GMDSS, sea area A2 is an area within MF coast station continuous digital selective calling coverage, excluding A1. The provision of MF DSC equipment and the corresponding distress alerting means for the trading area is a basic requirement of fitness for that area.
✗
Question 14. What is required for the maintenance of water ingress detectors on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: B (Tested at regular intervals and kept operational, with tests and maintenance recorded)
💡 SOLAS requires the water ingress detection system of a bulk carrier to be tested and maintained at regular intervals with records kept, so that it alarms reliably when flooding occurs. Long neglect of testing means the system may fail unnoticed.
✗
Question 15. What does SOLAS chapter III say about the performance standards for life-saving appliances?
Your Answer: (Not answered)
Correct Answer: C (the performance standards of the International Life-Saving Appliance Code, or other appliances accepted by the Administration as equally safe)
💡 Chapter III requires appliances to comply with the International Life-Saving Appliance Code, which standardises the testing and performance of rafts, boats, launching and embarkation appliances, fittings and pyrotechnics. Other appliances of equal safety may be accepted by the Administration, but only through type approval on the record. Class rules cover structure and machinery and do not set life-saving performance; a contractual specification below the Code prevents the issue of the equipment safety certificate and will be listed on inspection.
✗
Question 16. What is the hazardous characteristic of a Group A solid bulk cargo under the IMSBC Code?
Your Answer: (Not answered)
Correct Answer: B (It may liquefy if shipped above the TML, causing cargo shift and capsize)
💡 Group A cargoes contain fines and moisture and may liquefy, causing a shift of cargo and loss of stability. The hazard is physical, not chemical.
✗
Question 17. What reporting do SOLAS and the related rules require for ships carrying dangerous goods?
Your Answer: (Not answered)
Correct Answer: D (Report the class, quantity and location of the dangerous goods as required by the port State)
💡 SOLAS VII and the related rules require the ship to report the class, quantity and location on board of the dangerous goods as required by the port State, so that the port can respond promptly if an incident occurs.
✗
Question 18. A company is reviewing the scope statement of a Cargo Securing Manual. Which wording should be adopted?
Your Answer: (Not answered)
Correct Answer: A (the securing of cargo units such as containers, vehicles and portable tanks; solid and liquid bulk fall under their own codes, the manual being Administration-approved and available on board)
💡 The manual covers cargo units; solid and liquid bulk cargoes fall under their own codes and cannot be mixed in. It must be approved and kept available on board, and it does not replace the loading calculation. Narrowing it to one ship type, or leaving it to the Master's discretion, fails VI/5.
✗
Question 19. What checking of survival craft stowage cradles is required?
Your Answer: (Not answered)
Correct Answer: C (Check the structure for corrosion and deformation and the lashings and limiters for reliability)
💡 Survival craft cradles should be checked for serious corrosion or deformation of the structure and for the reliability of the lashings and limiters, with the sliding surfaces smooth so that launching is unobstructed. Structural failure would prevent launching or allow the craft to move in a seaway, a serious hazard.
✗
Question 20. The carriage of liquefied gases in bulk shall follow:
Your Answer: (Not answered)
Correct Answer: B (the International Gas Carrier Code (IGC Code))
💡 SOLAS VII/11: the carriage of liquefied gases in bulk shall follow the IGC Code.
✗
Question 21. What does SOLAS address regarding life-saving appliances when trading in cold climates?
Your Answer: (Not answered)
Correct Answer: C (The effect of low temperature on equipment performance and on survival must be considered, with insulating and warming provisions)
💡 SOLAS requires ships trading in cold climates to take account of the effect of low temperature on life-saving appliances, such as reduced battery capacity, difficulty in starting engines and changed equipment performance, and on survival, such as the risk of hypothermia, providing immersion suits, thermal protective aids and corresponding emergency supplies.
✗
Question 22. Which best describes the fundamental objective of SOLAS Chapter II-2?
Your Answer: (Not answered)
Correct Answer: C (To minimise fire risk and protect persons and the ship by fire prevention, detection and extinguishing)
💡 SOLAS II-2 combines fire prevention, detection and extinction, using structural protection, detection and alarm systems and fixed extinguishing systems. Extinguishing alone is only part of the objective.
✗
Question 23. How must Class 1 explosives be segregated from Class 4 flammable solids?
Your Answer: (Not answered)
Correct Answer: B (Segregation is required as set out in the Code and the Cargo Securing Manual)
💡 Incompatible dangerous goods must be segregated in accordance with the Code and the Cargo Securing Manual.
✗
Question 24. What is the core issue addressed by the International Grain Code in relation to stability?
Your Answer: (Not answered)
Correct Answer: D (The effect on stability of heeling moments arising from grain shifting and settling during the voyage)
💡 The International Grain Code requires the heeling moments from grain shifting and settling to be calculated and the residual stability verified for the prescribed angles of heel, preventing excessive list from grain shift.
✗
Question 25. A high-temperature exhaust pipe in the engine room is found without thermal insulation. The finding is?
Your Answer: (Not answered)
Correct Answer: D (Hot surfaces should be insulated to prevent ignition of combustibles; absence is a fire protection deficiency)
💡 Surfaces in a machinery space whose temperature could ignite combustibles or scald personnel, such as exhaust and steam pipes, should be insulated or otherwise protected as required. Unprotected they can become an ignition source when fuel or oil mist leaks. It is a fire protection deficiency to be corrected.
✗
Question 26. A PSCO asks how many separate means of escape each main vertical zone must have. What is the correct answer?
Your Answer: (Not answered)
Correct Answer: C (At least two)
💡 SOLAS II-2/13 requires at least two means of escape from each main vertical zone or similar space, remote from each other, so that one route is not cut off by fire or smoke.
✗
Question 27. The radar and ARPA are found without the required periodic performance tests and records. The finding is?
Your Answer: (Not answered)
Correct Answer: A (Radar and ARPA should be tested and recorded periodically; failure is a navigational equipment management deficiency)
💡 Radar and ARPA are key equipment for collision avoidance and positioning and should undergo periodic performance tests, such as display, range, gain, and ARPA acquisition and tracking, with records kept, to confirm they are in good working order. Without testing or records their reliability cannot be shown. It is a deficiency to be corrected.
✗
Question 28. What is required regarding the timeliness of system records?
Your Answer: (Not answered)
Correct Answer: A (Records must be completed truthfully and promptly when the event occurs, not written up in a batch later or in advance)
💡 System records, of inspections, maintenance, drills and training, should be completed truthfully and promptly at the time. Writing them up in a batch afterwards or in advance makes them inconsistent with reality, and inconsistencies such as times conflicting with the voyage are readily detected at an inspection and treated as falsification.
✗
Question 29. A ship is to load a concentrate liable to liquefy. Under SOLAS VI/1 which two key data must the shipper provide to the master before loading?
Your Answer: (Not answered)
Correct Answer: B (The moisture content and the transportable moisture limit (TML))
💡 SOLAS VI/1 and the IMSBC Code require the moisture content and the TML to be provided before loading. The cargo may be accepted only when the moisture content is below the TML; weight alone gives no indication of liquefaction risk.
✗
Question 30. What safety is required in ballast water operations?
Your Answer: (Not answered)
Correct Answer: A (Operate according to the plan with valve positions verified, preventing cross-connection between compartments or a sudden change in stability from misoperation)
💡 Ballast operations should follow the approved ballast plan with valve positions verified, preventing inadvertent opening of valves from cross-connecting compartments, contaminating cargo or producing a sudden change in stability. The operations should be recorded, and important ones carried out by experienced personnel with the bridge informed.
✗
Question 31. A PSCO checked the continuous synopsis record against the ship's history. What changes must the CSR record?
Your Answer: (Not answered)
Correct Answer: D (Significant events such as changes of name, flag, company, recognised organisation and class)
💡 SOLAS XI-1/5 requires the CSR to record the ship's history and significant changes, including changes of name, flag, company, recognised organisation and class, so the record is traceable. Incomplete or out-of-date entries are a deficiency.
✗
Question 32. A fixed fire detection and fire alarm system shall cover:
Your Answer: (Not answered)
Correct Answer: C (machinery spaces, accommodation spaces and control stations as specified)
💡 SOLAS II-2/7: a fixed fire detection and fire alarm system shall cover machinery spaces, accommodation spaces and control stations as specified.
✗
Question 33. A lifebuoy (liferaft) hydrostatic release unit is found beyond its specified service or renewal date. The finding is?
Your Answer: (Not answered)
Correct Answer: B (The overdue release unit prevents the liferaft from releasing automatically as required, a deficiency to be corrected)
💡 A hydrostatic release unit must be within its specified service life; beyond it reliability cannot be assured. If the ship sinks, a failed unit means the liferaft cannot float free automatically, directly endangering survival after abandonment. Any unit found overdue is recorded as a deficiency and must be replaced.
✗
Question 34. Which statement about the purpose of the international shore connection is correct?
Your Answer: (Not answered)
Correct Answer: A (To enable water to be supplied to the ship's fire main from the shore or another ship if necessary, its dimensions being internationally standardised)
💡 Under SOLAS II-2/10 the relevant ships should carry at least one international shore connection so that, if necessary, the ship's fire main can be connected to the fire system of the shore or another ship for an external supply of water. Its dimensions should be standardised and its accessories such as bolts and gaskets complete and properly stowed.
✗
Question 35. A section of the fire detection system fails to alarm during testing. What should be done?
Your Answer: (Not answered)
Correct Answer: C (Establish the cause at once, such as a failed detector, broken wiring or incorrect zoning, and repair it)
💡 A section that does not alarm means a fire there would not be detected in time. The cause must be established at once, whether a failed detector, broken wiring, incorrect zoning or an inhibited circuit, and repaired. Disabling the section or relying on another leaves a serious latent hazard.
✗
Question 36. What is required for periodic running of lifeboat engines?
Your Answer: (Not answered)
Correct Answer: B (Run at least once each week for not less than the prescribed period, checking the cooling and fuel systems)
💡 SOLAS requires the lifeboat engine to be run at least once each week for not less than the prescribed period, bringing it to normal operating condition and checking the cooling and fuel systems. Long neglect leads to difficulty in starting and the engine may not work when genuinely needed.
✗
Question 37. What must be done on receiving maritime safety information at sea?
Your Answer: (Not answered)
Correct Answer: B (Assess its effect on the voyage promptly, adjusting course or speed and informing those concerned as necessary)
💡 On receiving navigational warnings or weather warnings, the officer of the watch should promptly assess their effect on the route, speed and operations, adjusting the plan and informing the master and others as necessary. Recording alone is not sufficient.
✗
Question 38. Emergency lighting shall ensure illumination of:
Your Answer: (Not answered)
Correct Answer: D (escape routes, muster stations, embarkation stations, steering gear and fire pump spaces)
💡 SOLAS II-1/42 requires emergency lighting to cover escape routes, muster and embarkation stations, fire pump and steering gear spaces.
✗
Question 39. What marking shall survival craft have for night detection?
Your Answer: (Not answered)
Correct Answer: D (Lighting or retro-reflective material to aid detection)
💡 Lighting or retro-reflective material to aid detection.
✗
Question 40. What is required for the position of air pipe openings on deck?
Your Answer: (Not answered)
Correct Answer: B (Located where they are not readily flooded by seas, with effective closing appliances)
💡 SOLAS requires air pipe openings to be positioned where they are not readily flooded by seas, with effective closing appliances. A poor position allows water to enter the tanks directly, causing stability and structural problems.
✗
Question 41. What is the purpose of the water ingress detection system required on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: B (To give an alarm when water enters the cargo holds and fore and aft spaces, enabling the crew to detect and deal with it promptly)
💡 Under SOLAS XII/12 a bulk carrier should have water ingress detection and alarm systems for the cargo holds and the forepeak and similar spaces, giving an alarm on the bridge promptly when water enters so that the crew can detect the ingress early and take pumping, leak-hunting and damage control measures, preventing the situation from worsening. The testing of the system should be kept effective.
✗
Question 42. What additional safety measure does SOLAS require for remote closing of watertight doors from the bridge?
Your Answer: (Not answered)
Correct Answer: C (An audible and visual alarm before closing, so that persons can move clear)
💡 SOLAS requires an audible and visual alarm and a delay before remote closing of a watertight door from the bridge, giving persons nearby time to move clear and preventing injury. Visual confirmation is not sufficient when operating at a distance.
✗
Question 43. What does SOLAS address regarding the use of watertight doors in drills?
Your Answer: (Not answered)
Correct Answer: A (Closing and remote operation of watertight doors should be practised in drills so the crew is familiar with the procedure)
💡 SOLAS requires the closing and remote operation of watertight doors to be practised in drills, so that the crew is familiar with the procedure and the operating positions for closing doors in an emergency. A briefing alone does not ensure correct operation when it matters.
✗
Question 44. What is the purpose of the rescue quoit in a lifeboat's equipment?
Your Answer: (Not answered)
Correct Answer: A (Thrown to a person in the water to be grasped, the line being used to pull the person alongside)
💡 A rescue quoit with its buoyant line is thrown to a person in the water to be grasped, and the rescuers pull the person alongside using the line before lifting him out. It is basic equipment for recovering a person from the water and a key item in a rescue boat's equipment.
✗
Question 45. Which extinguisher is least suitable for a galley cooking oil fire?
Your Answer: (Not answered)
Correct Answer: C (Direct water jets)
💡 Water on a fat fire causes splashing and reignition; a blanket or fat-fire agent must be used.
✗
Question 46. What does the Polar Code address regarding safety equipment for ships in polar waters?
Your Answer: (Not answered)
Correct Answer: B (Equipment suited to the polar environment for life-saving, firefighting, ice protection and emergencies)
💡 The Polar Code requires equipment suited to the polar environment, such as thermally protective life-saving appliances, firefighting equipment suitable for low temperature, ice protection and de-icing arrangements and emergency communication and escape means. Ordinary water equipment is not sufficient.
✗
Question 47. What does SOLAS address regarding sounding pipes?
Your Answer: (Not answered)
Correct Answer: A (They must reach the bottom of the tank with reliable closing appliances, positioned for easy sounding without impairing watertightness)
💡 SOLAS requires sounding pipes to reach the bottom of the tank for accurate measurement, with reliable closing appliances, positioned for convenient sounding without impairing watertightness or safety. Pipes passing through accommodation spaces require particular care to prevent escape of vapour.
✗
Question 48. What is required for checking the tightness of hatch covers on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Periodic inspection of seals, cleats and drain channels with a hose test to verify weathertightness)
💡 SOLAS requires the hatch covers of a bulk carrier to remain weathertight, with periodic checks of seal ageing, the effectiveness of cleats and the clearance of drain channels, and a hose test where necessary to verify tightness, preventing sea water from entering the holds and damaging structure and cargo.
✗
Question 49. What does the monthly check and test of radio equipment normally include?
Your Answer: (Not answered)
Correct Answer: B (A more comprehensive performance test with records, including checks of the reserve source of energy)
💡 SOLAS and the GMDSS performance standards require a more thorough monthly check and performance test, including verification of the capacity of the reserve source and the change-over to emergency supply, with records kept.
✗
Question 50. Which Convention governs the ship's handling of ballast water?
Your Answer: (Not answered)
Correct Answer: B (The Ballast Water Management Convention)
💡 Ballast water is to be managed under the Ballast Water Management Convention.
✗
Question 51. A lifeboat shall be provided with at least how many buoyant smoke signals?
Your Answer: (Not answered)
Correct Answer: B (2)
💡 SOLAS III/34 requires at least two buoyant smoke signals in a lifeboat.
✗
Question 52. What is the purpose of the radar reflector among the lifeboat equipment?
Your Answer: (Not answered)
Correct Answer: C (To increase the radar echo of the boat so that it is detected by searching vessels)
💡 SOLAS requires a lifeboat to carry a radar reflector, increasing the radar echo so that searching vessels detect the boat at a greater distance, improving the chance of rescue.
✗
Question 53. What must the enclosed space entry testing record contain under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (The date, location, parameters tested and results, and the issue of the permit)
💡 SOLAS and the IMO resolutions require records of enclosed space entry testing and permits, including the date, the space, the parameters tested — oxygen, toxic and flammable gases — the results and the permit issued, for traceability and inspection.
✗
Question 54. What is the minimum number of lifebuoys for a cargo ship of 90 metres in length?
Your Answer: (Not answered)
Correct Answer: B (Eight)
💡 Under SOLAS III/32 a cargo ship of less than one hundred metres in length carries at least eight lifebuoys, the number increasing with length above that. The lifebuoys and their attachments such as self-igniting lights and lines must also meet the relevant requirements.
✗
Question 55. Which statement about the accounting for persons and boarding sequence during abandonment is correct?
Your Answer: (Not answered)
Correct Answer: D (All persons on board should be accounted for under the muster list and boarding carried out in order, giving priority to the injured and those with reduced mobility)
💡 During abandonment the persons on board, including watchkeepers and visitors, should be accounted for under the muster list and organised to board the survival craft in order, giving priority to the injured and those with reduced mobility, taking the required equipment, communication sets and necessary items. Abandoning without accounting leads to persons being left behind.
✗
Question 56. A container packing certificate shall be issued by:
Your Answer: (Not answered)
Correct Answer: D (the person or organisation responsible for packing the container)
💡 SOLAS VII/3: a container packing certificate shall be issued by the person or organisation responsible for packing the container.
✗
Question 57. What is the principal method of structural fire protection in accommodation and service spaces under SOLAS II-2?
Your Answer: (Not answered)
Correct Answer: B (Division into main vertical zones by class A and B divisions to limit fire spread)
💡 SOLAS II-2 protects accommodation and service spaces principally by fire-resisting divisions into main vertical zones with class A and B boundaries, rather than by extinguishing or detection equipment alone.
✗
Question 58. When a fire breaks out in a machinery space, what is the principle for dealing with the ventilation system?
Your Answer: (Not answered)
Correct Answer: A (Stop the relevant fans and close dampers and fire flaps, cutting off the supply of fresh air and the spread of smoke)
💡 When a fire breaks out in a machinery space the fans of the affected space should be stopped and the dampers and fire flaps closed, cutting off the fresh air supply and preventing smoke spreading to other spaces through the ducts and creating the closed condition needed for releasing a fixed extinguishing system. Increasing ventilation blindly feeds the fire.
✗
Question 59. What does routine checking of the bilge system include?
Your Answer: (Not answered)
Correct Answer: C (Strainers free of blockage, valves operating freely and pumps priming properly, with records kept)
💡 Routine checks of the bilge system should cover strainers and mud boxes for blockage and cleanliness, valves for free and correct operation and pumps for starting and priming, with records kept. Checking only in dry dock would leave the system failing in service without anyone knowing.
✗
Question 60. To which ships does the Polar Code apply?
Your Answer: (Not answered)
Correct Answer: C (Ships operating in polar waters, categorised as category A, B or C as applicable)
💡 SOLAS XIV/1 applies the Polar Code to ships operating in polar waters, categorised as A, B or C. Warships and fishing vessels outside the convention are not within its mandatory scope.
✗
Question 61. What do SOLAS and STCW emphasise about the master's instructions to the officer of the watch?
Your Answer: (Not answered)
Correct Answer: D (The master should issue clear standing and night orders, which the watchkeeper follows, with the orders recorded)
💡 STCW and SOLAS require the master to issue clear standing orders and night orders, normally in writing, which the officer of the watch is familiar with and follows, calling the master immediately in any unforeseen situation.
✗
Question 62. Which extinguishing medium should be used on an electrical fire?
Your Answer: (Not answered)
Correct Answer: A (A non-conducting medium such as CO2 or dry powder, with the power cut first)
💡 An electrical fire requires a non-conducting medium such as CO2 or dry powder with the power cut as soon as possible. Water or foam risks electric shock and further damage to equipment, and cutting the power is the first step.
✗
Question 63. Which certificate shall a ship hold under the ISPS Code?
Your Answer: (Not answered)
Correct Answer: A (ISSC)
💡 The International Ship Security Certificate.
✗
Question 64. On what basis is the Polar Ship Certificate issued, and what does it state?
Your Answer: (Not answered)
Correct Answer: D (issued on the results of survey, attesting conformity with the applicable polar safety and pollution requirements and recording the category and the limits)
💡 The work comes before the paper: before trading in polar waters the ship is assessed for the areas she intends to reach, a polar water operational manual is built on that assessment covering both safety and pollution prevention, and survey then establishes that the arrangements, equipment, training and manual on board answer one another. The certificate records the ship's category, the ice conditions she may operate in, the limitations and any exemptions attached, and is examined and renewed as required. The category is tied to the life-saving, fire and radio arrangements, so ice class alone says nothing; and a class notation for ice is given under the society's own rules, which is not the category in the Code. Without the certificate the ship does not trade there, and a master cannot plead that this voyage meant to stay clear of ice.
✗
Question 65. What are the requirements for using a ship's call sign and identity?
Your Answer: (Not answered)
Correct Answer: C (Use the registered call sign and MMSI, never another ship's identity or an incorrect code)
💡 Ship radio communication must use the registered call sign and MMSI. Using another ship's identity or an incorrect number misleads coast stations and other ships and, in a distress, affects the location of the casualty, and is a serious breach.
✗
Question 66. What is the main purpose of the two-way VHF radiotelephone apparatus carried in survival craft?
Your Answer: (Not answered)
Correct Answer: C (On-scene communication between the survival craft and rescuing ships or aircraft)
💡 SOLAS III requires a two-way VHF set in survival craft for on-scene communications with rescuing ships and aircraft after abandonment. It is not for routine internal use.
✗
Question 67. What does SOLAS address regarding the function of the double bottom in the event of damage?
Your Answer: (Not answered)
Correct Answer: B (The inner space limits flooding and protects the inner bottom structure when the bottom is damaged)
💡 One of the principal reasons SOLAS requires a double bottom is that when the bottom is damaged by grounding or stranding, the double bottom space limits the extent of flooding and protects the inner bottom structure, reducing the volume of water admitted and improving survivability.
✗
Question 68. Which means of look-out meets SOLAS requirements?
Your Answer: (Not answered)
Correct Answer: A (Sight, hearing and all available means appropriate to the circumstances)
💡 Sight, hearing and all available means appropriate to the circumstances.
✗
Question 69. A ship's AIS is found switched off while under way. The finding is?
Your Answer: (Not answered)
Correct Answer: B (AIS must be kept in operation as required and may be switched off only in the specified circumstances; failing to keep it on is a violation)
💡 The AIS should be kept in operation as required and may be switched off only in the specific cases permitted by the rules, such as where continuous operation would compromise the safety or security of the ship, and the reason should be recorded. Switching it off at will while under way is a violation that may lead to detention and investigation.
✗
Question 70. What is required on completion of a job?
Your Answer: (Not answered)
Correct Answer: B (Clear the site, restore equipment and guards, close the permit and keep records)
💡 On completion of a job the site should be cleared of oil, debris and tools, the guards and safety devices removed for access restored, such as rails, gratings and covers, the permit closed and the persons and tools accounted for, with the completion recorded, preventing hazards from being left behind.
✗
Question 71. What does SOLAS address regarding the equilibrium condition in damage stability calculations?
Your Answer: (Not answered)
Correct Answer: B (After flooding the ship must satisfy the residual stability criteria in the equilibrium condition)
💡 SOLAS requires that, once the ship reaches equilibrium after flooding, taking account of the water entered and the resulting heel, the residual stability curve satisfies the prescribed criteria such as the range of righting levers and the maximum righting lever. Intact stability criteria alone are not a substitute.
✗
Question 72. The bow structure requirements for bulk carriers mainly address:
Your Answer: (Not answered)
Correct Answer: B (carriage of high-density solid bulk cargoes such as ore)
💡 SOLAS XII/9: the bow structure requirements address the carriage of high-density solid bulk cargoes such as ore.
✗
Question 73. What is the time requirement for launching and recovering a rescue boat under SOLAS III?
Your Answer: (Not answered)
Correct Answer: B (Recovery must be possible within 5 minutes in moderate sea conditions)
💡 SOLAS III requires a rescue boat to be capable of being launched and recovered within 5 minutes in moderate sea conditions, so that a person in the water can be recovered quickly.
✗
Question 74. What does SOLAS II-2 require for the sounding pipes of fuel oil tanks in machinery spaces?
Your Answer: (Not answered)
Correct Answer: D (Self-closing shut-off devices to prevent oil escaping)
💡 SOLAS requires sounding pipes of fuel tanks to be fitted with self-closing devices and a self-closing cock below the deck, preventing accidental escape of oil. A cap alone is not sufficient.
✗
Question 75. How must operating instructions and markings for equipment be managed?
Your Answer: (Not answered)
Correct Answer: B (Clear instructions and warnings, available near the equipment and kept in good condition)
💡 Operating instructions and warning markings for critical equipment should be provided near the equipment, clear and in good condition, not fallen off or illegible, so that the operator can consult them at any time. Relying on memory without markings makes errors likely after a change of personnel or under pressure.
✗
Question 76. How is the value of the subdivision index R related to ship type?
Your Answer: (Not answered)
Correct Answer: D (For passenger ships it is determined by length and zone of service, and there are prescribed values for cargo ships)
💡 SOLAS II-1 prescribes values of the subdivision index R by ship type — for passenger ships by length and zone of service, and prescribed values for cargo ships. It is neither uniform nor a matter of choice.
✗
Question 77. On encountering a danger to navigation such as an uncharted shoal, what does SOLAS V require of the master?
Your Answer: (Not answered)
Correct Answer: B (To communicate the information immediately to ships in the vicinity and to the competent authority)
💡 SOLAS V/31 requires the master to communicate such dangers immediately to ships nearby and to the competent authority so that a navigational warning can be issued. A log entry alone is insufficient.
✗
Question 78. What communication is required for key shipboard operations?
Your Answer: (Not answered)
Correct Answer: D (Operations involving several parties must have a designated person in charge, maintained communication and confirmation of key steps)
💡 The ISM Code requires key operations involving several persons or departments, such as cargo work, ballasting, bunkering and hot work, to have a designated person in charge, a communication arrangement including a briefing before starting and confirmation of the key steps, preventing accidents or pollution from a failure of communication.
✗
Question 79. On a passenger ship, each space shall be provided with at least how many means of escape?
Your Answer: (Not answered)
Correct Answer: D (2)
💡 SOLAS II-2/13 requires at least two widely separated means of escape from each space on a passenger ship.
✗
Question 80. What is the purpose of a ship's echo sounder?
Your Answer: (Not answered)
Correct Answer: D (To measure the depth of water from the keel to the seabed, assisting navigation, positioning and shallow-water warning)
💡 Under SOLAS V/19 a ship of 3000 gross tonnage and above should be provided with an echo sounder to measure the depth of water from the keel to the seabed, assisting in judging depth changes, giving shallow-water warning and cross-checking position, especially useful in shoal areas, at anchor and when berthing.
✗
Question 81. Where must the distress signals of a lifeboat be stowed?
Your Answer: (Not answered)
Correct Answer: A (In a watertight container inside the lifeboat, readily available and protected from damp)
💡 SOLAS requires the distress signals to be stowed in a watertight container in the lifeboat, protected from damp and available at hand if the ship is abandoned. Stowing them on the bridge or in a store would make them unavailable.
✗
Question 82. What shall be the relationship between the main and emergency sources of power?
Your Answer: (Not answered)
Correct Answer: A (They are independent and the emergency source takes over automatically)
💡 They shall be independent and the emergency source shall take over automatically.
✗
Question 83. What does SOLAS require for change-over of power supplies for radio equipment?
Your Answer: (Not answered)
Correct Answer: A (Change-over between the main and reserve sources must be completed within the prescribed time, keeping communication unbroken)
💡 SOLAS requires radio equipment to be capable of rapid change-over between the main and reserve sources, so that distress and safety communication is not interrupted for a long period by the change. The change-over arrangement should be tested periodically for reliability.
✗
Question 84. What confidentiality applies to the ship security plan?
Your Answer: (Not answered)
Correct Answer: C (Unauthorised access to its contents must be prevented, with the document marked and distribution restricted)
💡 The ISPS Code requires the ship security plan to be a confidential document, marked as such, with restricted distribution and protected against unauthorised access, including electronic versions, preventing the security measures from being circumvented. It may be shown to authorised persons on inspection.
✗
Question 85. What is the difference between the bulkhead deck and the freeboard deck under SOLAS II-1?
Your Answer: (Not answered)
Correct Answer: C (The bulkhead deck limits the extent of the main watertight bulkheads, while the freeboard deck is the datum for freeboard and load line)
💡 The bulkhead deck is the uppermost deck to which the main watertight bulkheads extend, whereas the freeboard deck is the datum for measuring freeboard and assigning load lines. Their roles in subdivision and load line calculations differ.
✗
Question 86. The continuous synopsis record is examined during a PSC inspection. What does the CSR record?
Your Answer: (Not answered)
Correct Answer: A (The ship's history and significant events, such as changes of name, flag, company and recognised organisation)
💡 SOLAS XI-1/5 requires the CSR to record the history of the ship and significant events, including changes of name, flag, company and recognised organisation, so that the ship's record can be traced.
✗
Question 87. What is sea area A1?
Your Answer: (Not answered)
Correct Answer: D (An area within coverage of at least one VHF coast station)
💡 An area within coverage of at least one VHF coast station with DSC.
✗
Question 88. What do SOLAS and good practice address regarding testing the emergency source of power?
Your Answer: (Not answered)
Correct Answer: A (Periodic testing of automatic starting, change-over and the ability to carry load, with records kept)
💡 SOLAS and good practice require periodic testing of the automatic starting, change-over and load carrying capability of the emergency source, verifying that it can take up the emergency load as prescribed when the main source fails, with records kept for verification at survey.
✗
Question 89. While underway the ship receives word from her Administration that the security level has been raised, while the terminal remains at the former level. What applies on board?
Your Answer: (Not answered)
Correct Answer: A (the notified level being implemented with the master's instructions, co-ordinated with the port facility security officer, the facility's own level not reducing the ship's duty)
💡 Levels are set for the ship by her Administration and for the facility by the Contracting Government; on notice of an increase the ship implements the additional measures of her plan for that level, informs the master, crew and the facility concerned, and settles any mismatch by co-ordination. The terminal staying at the lower level does not reduce the ship's duty, and relaxing the ship to match it is not the answer.
✗
Question 90. A ship is 180 m in length. What is the minimum number of lifebuoys under SOLAS III/7.1?
Your Answer: (Not answered)
Correct Answer: A (18)
💡 SOLAS III/7.1 sets bands by length: under 60 m — 8; 60 to 120 m — 12; 120 to 180 m inclusive — 18; over 180 m — 24. A length of 180 m falls in the third band.
✗
Question 91. A ship is 90 m in length. Must she carry a rescue boat under SOLAS III/17?
Your Answer: (Not answered)
Correct Answer: D (Yes; a cargo ship must carry a rescue boat, and a lifeboat meeting the requirements may serve as one)
💡 SOLAS III/17 requires cargo ships to carry a rescue boat. A lifeboat complying with the requirements for a rescue boat may be accepted as one. A length below 100 m is not a ground for exemption.
✗
Question 92. What does SOLAS require for suction valves in watertight bulkheads?
Your Answer: (Not answered)
Correct Answer: D (Suction valves below the waterline must be capable of remote operation from above the bulkhead deck)
💡 SOLAS requires overboard and bulkhead suction valves below the waterline to be operable by remote control from above the bulkhead deck, so that they need not be operated by hand in a space which may already be flooded.
✗
Question 93. What does SOLAS require for communication between the bridge and machinery space?
Your Answer: (Not answered)
Correct Answer: B (Reliable means must be provided so that the bridge and machinery space can communicate at all times)
💡 SOLAS requires reliable means of communication, such as telegraph or telephone, between the bridge and machinery space at all times. A mobile phone is not an acceptable compliant means.
✗
Question 94. What are the key points in simulating search and rescue in a fire drill?
Your Answer: (Not answered)
Correct Answer: B (Practise donning breathing apparatus, entering with firefighter's equipment to search and moving casualties)
💡 A fire drill should include simulated entry for search and rescue: donning breathing apparatus, taking the axe and safety lamp, using a hose for protection and searching for and moving casualties, so that the crew acquires the skills needed in a smoke filled environment.
✗
Question 95. What is required regarding toolbox meetings?
Your Answer: (Not answered)
Correct Answer: C (A short meeting before starting work to confirm the task, risks, duties and safety measures)
💡 The ISM Code and good practice require a toolbox meeting before work starts, particularly for high risk or complex work, at which the person in charge explains the task, the risks identified, the safety measures, the allocation of duties and the emergency arrangements and confirms that those taking part understand them, preventing accidents from inadequate communication.
✗
Question 96. What is the basic principle for the provision of lifejackets?
Your Answer: (Not answered)
Correct Answer: D (One for every person on board, with additional ones for watchkeepers, remote locations and survival craft stations)
💡 Under SOLAS III/7 and III/32 a lifejacket should be provided for every person on board, with additional ones to meet the needs of watchkeeping positions, remote locations and survival craft stations, so that one can be obtained at any time and place.
✗
Question 97. For a ship without an approved treatment plant, what is the general distance requirement for the discharge of sewage?
Your Answer: (Not answered)
Correct Answer: C (Beyond 12 nautical miles from the nearest land and at the specified speed)
💡 Under MARPOL Annex IV, where no approved treatment plant is fitted, sewage may generally be discharged beyond twelve nautical miles from the nearest land and subject to speed and other conditions, while a ship with an approved plant may discharge closer when the conditions are met. Port States may also have stricter local rules.
✗
Question 98. What is the basic principle for selecting portable extinguishers for a machinery space?
Your Answer: (Not answered)
Correct Answer: B (the class of fire likely in the space deciding the choice, oil and electrical fires requiring a suitable agent, the number and siting as prescribed)
💡 In a machinery space the likely fires are oil and electrical. Water will spread a burning oil fire and carries the shock risk on live equipment, so it belongs to solid combustible fires; here foam, powder or carbon dioxide suits the class, with the capacity, number and siting the rules call for along passages and in spaces, placed where a hand can reach it and not blocked by gear or cargo. Carbon dioxide released in quantity in a small closed space drives the oxygen down, which has to be thought of as the party withdraws. Counting only the extinguishers and their service dates, without regard to whether the type suits the space, is a deficiency waiting to be written up and a mistake waiting to be made at the fire itself.
✗
Question 99. What overload protection is required for electrical equipment?
Your Answer: (Not answered)
Correct Answer: C (Overload protection for essential motors and cables, preventing overheating which damages insulation and causes fire)
💡 SOLAS requires overload protection for essential motors, cables and distribution equipment, operating to trip or alarm on overload, preventing prolonged overheating from ageing the insulation and causing an electrical fire, particularly in the high temperature environment of a machinery space.
✗
Question 100. Which account of the segregation of dangerous goods holds up?
Your Answer: (Not answered)
Correct Answer: A (keeping the goods apart as the IMDG Code requires, from other dangerous goods, from foodstuffs and from accommodation)
💡 Segregation pulls chemically unsuitable substances apart horizontally and vertically to the level the Code gives, so that a leak does not bring them into reaction, foul foodstuffs or reach accommodation; on the stowage plan that becomes the choice of hold and tier, the distance from heat and from living spaces, and the number each term - away from, separated from - calls for. It is not advice and two parties cannot agree it away: the levels already reckon the consequence of a leak, and an agreed change of position may only be made within what the level demands. One hold with two tiers commonly does not satisfy it, some combinations calling for a different hold or separation by a complete deck. The requirement belongs in the plan prepared before loading and is re-worked whenever the stow changes.