Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. In which spaces must a bulk carrier be fitted with water ingress detection and alarm systems?
Your Answer: (Not answered)
Correct Answer: C (Cargo holds, ballast tanks and dry spaces)
💡 SOLAS XII/12 requires water level detectors with alarms in cargo holds, ballast tanks and dry spaces so that flooding is detected early.
✗
Question 2. What is the maximum period of validity of a Passenger Ship Safety Certificate?
Your Answer: (Not answered)
Correct Answer: B (12 months)
💡 SOLAS I/8: the Passenger Ship Safety Certificate shall be valid for not more than 12 months.
✗
Question 3. What should be met as to the stowage position of two-way radiotelephones and SARTs?
Your Answer: (Not answered)
Correct Answer: D (They should be positioned for easy carriage to the survival craft in an abandonment, such as on the bridge and near the survival craft stations)
💡 Under SOLAS IV/7 and related requirements two-way radiotelephones and SARTs should be positioned where they can be readily obtained and taken into the survival craft during abandonment, such as on the bridge and near the survival craft stations. If stowed together there should be clear marking and ready access, so that they are not left behind.
✗
Question 4. Which equipment does a ship in sea area A3 use to receive maritime safety information and satisfy GMDSS?
Your Answer: (Not answered)
Correct Answer: A (An enhanced group calling (EGC) receiver)
💡 Beyond NAVTEX coast station coverage, a ship in sea area A3 must use EGC to receive SafetyNET MSI. NAVTEX is available only within A1 and A2 coverage.
✗
Question 5. What is the consequence of directing a solid water jet onto burning oil in a machinery space fire?
Your Answer: (Not answered)
Correct Answer: A (It may splash and spread the burning oil and enlarge the fire; foam or water spray should be used to cover the surface)
💡 A solid jet striking burning oil splashes and spreads it, enlarging the fire and endangering personnel. Oil fires should be smothered with foam or cooled with water spray; a solid jet must not be used.
✗
Question 6. An inflatable liferaft is found beyond its annual service interval and not serviced at an approved service station. The finding is?
Your Answer: (Not answered)
Correct Answer: D (Liferafts must be serviced at the required intervals; being overdue means reliability cannot be assured, a deficiency to be corrected)
💡 An inflatable liferaft should be serviced at an approved service station at the required intervals, normally not exceeding twelve months, when its body, gas cylinder, equipment and inflation arrangements are checked. Being overdue, its inflation and buoyancy reliability cannot be assured. It is a deficiency affecting life-saving capability and should be sent for service.
✗
Question 7. How long must dangerous goods documentation be kept on board?
Your Answer: (Not answered)
Correct Answer: A (For the prescribed period, normally until some time after discharge at the port of destination, for traceability and investigation)
💡 The documentation for dangerous goods, the manifest, stowage plan and special cargo information, must be retained for the prescribed period, normally until a certain time after discharge at the port of destination depending on the rules, so that the nature and stowage of the goods can be traced in the event of an incident or pollution.
✗
Question 8. The ECDIS safety contour and safety depth settings are found not adjusted according to the voyage for a long time. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Safety parameters must be set for each voyage and draught; not adjusting them is an operational deficiency)
💡 Parameters such as the ECDIS safety contour, safety depth and shallow contour should be set sensibly for the water, draught and under-keel clearance of each voyage so that shallow-water and danger alarms work effectively. Leaving them unchanged makes the alarms meaningless. It is an operational deficiency to be corrected.
✗
Question 9. What language does SOLAS require for life-saving appliance markings?
Your Answer: (Not answered)
Correct Answer: C (The working language of the ship or English, with operating illustrations)
💡 SOLAS requires markings and instructions on life-saving appliances to be in the working language of the ship or in English, with illustrations, so that seafarers of different nationalities can understand them.
✗
Question 10. Class A and class B divisions: what separates them?
Your Answer: (Not answered)
Correct Answer: A (class A of steel or equivalent with non-combustible insulation, stopping flame and smoke; class B need only be non-combustible and for a shorter time)
💡 Three things decide the class: the material, the limit on temperature rise on the unexposed face, and the time the division stands up to the standard fire test. Class A asks for steel or equivalent material with non-combustible insulation behind, so that neither flame nor smoke passes, and for the longest test period; class B asks only that the material be non-combustible, with lower insulation and strength and a much shorter time holding flame. Either class may be a bulkhead or a deck, the name not fixing the use; which class a boundary needs depends on how dangerous the space is, whether the ship carries passengers or cargo, and what the rules require around machinery spaces, stairways and control stations. Cut a hole for a pipe and leave it unsealed and the division stops being what it was, which is the commonest thing an inspection finds.
✗
Question 11. From what tonnage shall speed and distance measuring equipment be fitted?
Your Answer: (Not answered)
Correct Answer: B (500 GT)
💡 500 GT and above.
✗
Question 12. What should be noted when using HF for long range communication?
Your Answer: (Not answered)
Correct Answer: C (Choose the appropriate band according to time and distance, taking account of ionospheric conditions, and establish contact after a test call)
💡 HF communication relies on ionospheric reflection, and the suitable band differs by day and night and with distance, higher bands by day and lower bands at night. Contact should be established after the prescribed test call with the frequency watched. A single fixed frequency often means no contact at all.
✗
Question 13. What is the main purpose of the requirements for fire main diameter and pressure?
Your Answer: (Not answered)
Correct Answer: A (To ensure that the required number of jets can be supplied simultaneously with effective reach)
💡 The SOLAS II-2 requirements for fire main diameter and pressure ensure that the required number of jets can be maintained simultaneously at an effective reach when the fire pumps are running.
✗
Question 14. Communication between the engine room and bridge fails at sea so that telegraph orders cannot be confirmed. What does SOLAS II-1 require regarding control of the main machinery?
Your Answer: (Not answered)
Correct Answer: D (The main machinery must be controllable from the bridge, with an independent control position in the machinery space)
💡 SOLAS II-1 requires the main machinery to be operable from the navigation bridge while an independent control position is retained in the machinery space, so the machinery can still be controlled if bridge control fails.
✗
Question 15. What does the ISM Code provide regarding the master's responsibility and authority?
Your Answer: (Not answered)
Correct Answer: B (The master has overriding authority in matters of safety and pollution prevention, which the company must state in writing)
💡 ISM Code 5 gives the master overriding authority in matters of safety and pollution prevention, and requires the company to document this in writing. It is a cornerstone of the SMS.
✗
Question 16. What is the maximum interval for servicing an inflatable liferaft?
Your Answer: (Not answered)
Correct Answer: C (12 months)
💡 SOLAS III/20: inflatable liferafts shall be serviced at an approved station at intervals not exceeding 12 months.
✗
Question 17. What do SOLAS and good practice recommend for the handling of survival craft after abandonment?
Your Answer: (Not answered)
Correct Answer: B (Move clear of the ship as soon as possible, avoiding suction by the sinking ship or being trapped by burning oil)
💡 After abandonment, survival craft should be moved clear of the ship as soon as possible, avoiding the suction of a sinking ship, falling debris or being surrounded by burning oil. Remaining close to the ship greatly increases the danger.
✗
Question 18. After failure of the main source of power, within what period must the emergency generator take over automatically?
Your Answer: (Not answered)
Correct Answer: A (Within 45 seconds)
💡 SOLAS II-1/41 requires the emergency generator to start automatically and connect to the emergency switchboard within 45 seconds. Fifteen seconds applies to the transitional reserve source of power (batteries).
✗
Question 19. What capability should the bridge retain when navigating in ice?
Your Answer: (Not answered)
Correct Answer: D (The ability to manoeuvre at any time at an appropriate speed, with engines on standby if necessary)
💡 Navigation in ice requires engines on standby, controlled speed and the ability to manoeuvre at any time, avoiding damage from changing ice conditions. Driving at full speed or shutting down the engine carries serious risk.
✗
Question 20. What are the limitations on the use of the automatic pilot?
Your Answer: (Not answered)
Correct Answer: B (Hand steering must be resumed in restricted visibility, dense traffic, narrow channels or when frequent manoeuvring is required)
💡 STCW and SOLAS require hand steering to be resumed in restricted visibility, dense traffic, narrow channels or when frequent manoeuvring is needed on ships using an automatic pilot. The autopilot does not reduce the number of look-outs required and the officer must be ready to steer by hand at any time.
✗
Question 21. How do the fire requirements for vehicle and ro-ro spaces differ from ordinary cargo holds?
Your Answer: (Not answered)
Correct Answer: A (Because vehicles carry fuel and the spaces are large, a fixed extinguishing system and effective drainage are required)
💡 SOLAS II-2/20 lays down specific requirements for vehicle and ro-ro spaces, including fixed extinguishing systems and drainage, because vehicles carry fuel and fire spreads rapidly between them.
✗
Question 22. What protection does SOLAS require for electric and electrohydraulic steering gear?
Your Answer: (Not answered)
Correct Answer: A (Short circuit and overload protection, with an alarm for single phase failure)
💡 SOLAS II-1/30 requires electric and electrohydraulic steering gear to have short circuit and overload protection and to give an alarm in the event of a single phase failure, preventing sudden loss of steering.
✗
Question 23. Which describes the periodical survey under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (Carried out periodically and may replace an annual survey)
💡 The periodical survey may replace one of the annual surveys.
✗
Question 24. How often must inflatable liferafts be serviced under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (At intervals not exceeding 12 months at an approved servicing station)
💡 SOLAS requires inflatable liferafts to be serviced at intervals not exceeding 12 months at an approved servicing station, while rigid lifeboats are subject to the prescribed annual inspection. The crew cannot replace the approved servicing.
✗
Question 25. What is required for route monitoring when using electronic charts?
Your Answer: (Not answered)
Correct Answer: B (Continuously monitor the deviation from the planned route, act on and acknowledge safety alarms and correct as necessary)
💡 When ECDIS is in use the deviation from the planned route should be monitored continuously and safety alarms such as off-track and approaching danger acted on and acknowledged, with course corrections as necessary. Setting the route and then neglecting to monitor it is not acceptable.
✗
Question 26. What does SOLAS address regarding fire protection of the cargo pump room on a tanker?
Your Answer: (Not answered)
Correct Answer: D (Class A divisions at its boundaries with a fixed extinguishing system and fire detection inside)
💡 SOLAS requires the boundaries of a cargo pump room on a tanker to be class A divisions, with a fixed extinguishing system, normally CO2 or foam, and fire detection inside, since the pump room is a high risk space for accumulation and explosion of vapour.
✗
Question 27. Where an enclosed means of escape is provided from a category A machinery space, what minimum fire protection does SOLAS II-2/13.4.3 require?
Your Answer: (Not answered)
Correct Answer: C (A-60 class division)
💡 SOLAS II-2/13.4.3 requires the enclosed means of escape from a category A machinery space to be of A-60 standard so that the route remains usable during a machinery space fire.
✗
Question 28. What shall the bridge visibility design ensure?
Your Answer: (Not answered)
Correct Answer: C (A continuous view of the sea surface ahead and around from the conning position)
💡 An uninterrupted view of the sea surface from the conning position.
✗
Question 29. What emergency medical equipment must be carried?
Your Answer: (Not answered)
Correct Answer: D (A first aid kit, oxygen resuscitation equipment, a stretcher, splints and similar basic equipment, kept serviceable)
💡 A ship should carry basic first aid equipment: a first aid kit appropriate to the trading area, oxygen resuscitation equipment, a stretcher, splints and a tourniquet, kept serviceable and inspected periodically. Medicines without equipment cannot deal with fractures, asphyxia and similar emergencies.
✗
Question 30. What is the main purpose of the main engine and steering gear information required on board?
Your Answer: (Not answered)
Correct Answer: B (To enable the master to know the machinery and steering response and plan safe manoeuvres)
💡 SOLAS requires information on the main engine and steering gear so the master understands acceleration, deceleration and steering response, and can plan berthing and narrow channel manoeuvres.
✗
Question 31. What does SOLAS V/34 require of the master when using a ships' routeing system?
Your Answer: (Not answered)
Correct Answer: A (To use the system in accordance with the relevant rules, at a safe speed and with good seamanship)
💡 Ships must follow routeing systems; the master must apply them with a safe speed and good seamanship and may not depart from them simply to shorten the passage.
✗
Question 32. What is required for emergency steering drills carried out by the crew?
Your Answer: (Not answered)
Correct Answer: D (At least once every three months, including direct control from the steering gear compartment)
💡 SOLAS III/19 requires emergency steering drills at least every three months, including direct steering from the steering gear compartment and the communication procedure with the bridge. A briefing is not a substitute.
✗
Question 33. Under SOLAS Chapter IX, which certificate shall the Company hold?
Your Answer: (Not answered)
Correct Answer: B (DOC)
💡 The Document of Compliance (DOC).
✗
Question 34. Among the information entered into AIS, which is static?
Your Answer: (Not answered)
Correct Answer: B (The IMO number, call sign and ship's name, being fixed particulars of the ship)
💡 AIS static information includes the IMO number, call sign, name and type of ship, entered at installation and rarely changed. Position, course and speed are dynamic; destination and ETA are voyage related.
✗
Question 35. Regarding main and emergency sources of electrical power, which statement is correct?
Your Answer: (Not answered)
Correct Answer: A (the emergency source comes into operation automatically upon failure of the main source)
💡 SOLAS II-1 requires the emergency source to come into operation automatically upon failure of the main source, being independent from it.
✗
Question 36. On what basis is the extent of close-up survey determined?
Your Answer: (Not answered)
Correct Answer: A (Ship type, age, cargo characteristics and known high risk areas taken together)
💡 The ESP requires the extent of close-up survey to be determined by the ship type and age, the characteristics of the cargoes carried, such as the corrosive or abrasive effect of coal and ore, and the known high risk areas such as hatch coamings and hopper tanks, supported by a survey programme.
✗
Question 37. What is required for checking the tightness of hatch covers on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Periodic inspection of seals, cleats and drain channels with a hose test to verify weathertightness)
💡 SOLAS requires the hatch covers of a bulk carrier to remain weathertight, with periodic checks of seal ageing, the effectiveness of cleats and the clearance of drain channels, and a hose test where necessary to verify tightness, preventing sea water from entering the holds and damaging structure and cargo.
✗
Question 38. When a fixed CO2 system serves a machinery space, what key parameter does SOLAS address?
Your Answer: (Not answered)
Correct Answer: C (The quantity released must achieve the prescribed extinguishing concentration and the space must be reasonably gas-tight)
💡 SOLAS requires the CO2 quantity to be calculated from the volume of the space to achieve the prescribed concentration, and the space to be reasonably gas-tight so that leakage does not defeat the system.
✗
Question 39. What is the purpose of electronic position fixing and navigation systems such as satellite systems on board?
Your Answer: (Not answered)
Correct Answer: A (To provide continuous position and navigation information supporting navigation and collision avoidance)
💡 Electronic position fixing systems such as satellite systems provide continuous position, course and speed information forming the basis of navigation and collision avoidance. Their accuracy and reliability must be monitored and cross-checked.
✗
Question 40. What should be done if dangerous goods packages are found damaged on board?
Your Answer: (Not answered)
Correct Answer: B (Take the measures in the EmS Guide, segregate the damaged packages, protect personnel and assess whether carriage may continue)
💡 On discovering damaged packages of dangerous goods, the measures in the EmS Guide should be taken: segregating the damaged packages, protecting personnel and ventilating, collecting the spillage and notifying the port and the company where necessary, assessing whether carriage may continue or the goods must be discharged. Discarding them at random or ignoring the matter is not acceptable.
✗
Question 41. Which of the following must be included in a distress alert sent by DSC?
Your Answer: (Not answered)
Correct Answer: C (Ship's identification and her position at the time)
💡 A DSC distress alert carries the ship's identity, position, nature of distress and the time of the alert.
✗
Question 42. What is the maximum interval between ship security drills required by the ISPS Code?
Your Answer: (Not answered)
Correct Answer: C (Three months)
💡 ISPS Code Part A/13 and SOLAS XI-2 require ship security drills at intervals of not more than three months, with additional drills where the security level changes.
✗
Question 43. In what condition must a lifeboat be kept while stowed?
Your Answer: (Not answered)
Correct Answer: C (In a condition of immediate readiness for launching, with securing arrangements that can be released quickly without impairing safety)
💡 SOLAS requires a lifeboat when stowed to be ready for immediate launching: equipment complete on board, a gravity davit in a releasable condition and securing arrangements that hold the boat secure at sea yet can be released quickly in an emergency. Multiple lashings or dismantled parts would delay abandonment.
✗
Question 44. What cooperation with an investigation is required?
Your Answer: (Not answered)
Correct Answer: B (Preserve the scene and evidence, including VDR data and records, provide information truthfully and cooperate with the investigation)
💡 After a casualty the scene should be preserved and relevant evidence retained, such as VDR data, the deck and engine logs, photographs and statements, with information provided truthfully and cooperation given to the investigation by the company, flag State or port State. Clearing the scene or altering records obstructs the establishment of the cause and may be unlawful.
✗
Question 45. Fire drills shall be conducted at least:
Your Answer: (Not answered)
Correct Answer: D (once a month)
💡 SOLAS III/19: fire drills shall be conducted at least once a month.
✗
Question 46. What pressure testing does the fire main require?
Your Answer: (Not answered)
Correct Answer: B (Periodic pressure testing, normally annually, confirming no leakage in the piping and valves at the rated pressure)
💡 SOLAS and good practice require periodic pressure testing of the fire main, normally annually at not less than the design working pressure, confirming that the piping, valves and joints show no leakage or deformation under pressure, ensuring a reliable water supply in a fire.
✗
Question 47. Who shall approve the Cargo Securing Manual?
Your Answer: (Not answered)
Correct Answer: A (The Administration or its recognized organization)
💡 The Administration or its recognized organization.
✗
Question 48. What is the usual replacement interval for a hydrostatic release unit of an inflatable liferaft?
Your Answer: (Not answered)
Correct Answer: A (Not more than twelve months, checked or replaced with the annual liferaft service)
💡 A hydrostatic release unit should be checked together with the annual service of the liferaft and replaced at the required interval, normally not more than twelve months, so that it operates reliably and lets the liferaft float free when the ship sinks.
✗
Question 49. Indication of propeller pitch and speed shall show:
Your Answer: (Not answered)
Correct Answer: B (pitch (where applicable), propeller speed and direction of rotation)
💡 SOLAS V/19: the bridge shall be provided with indicators for pitch (where applicable), propeller speed and direction of rotation.
✗
Question 50. What should be done if a cable penetration seal in a division is damaged?
Your Answer: (Not answered)
Correct Answer: B (Repair promptly with an approved penetration seal to restore the fire and smoke integrity of the division)
💡 A damaged cable penetration seal leaves an opening through the division and should be repaired promptly with an approved penetration seal. Filling it with cement, foam or unsuitable material does not provide equivalent fire and smoke performance and is a deficiency.
✗
Question 51. In which frequency band does a search and rescue radar transponder operate?
Your Answer: (Not answered)
Correct Answer: C (9 GHz (X band))
💡 A SART operates in the 9 GHz band; when interrogated by a 9 GHz radar it produces a series of response blips on the rescuing ship's display. 406 MHz is the EPIRB frequency.
✗
Question 52. What is the total embarkation and launching time for survival craft on a passenger ship?
Your Answer: (Not answered)
Correct Answer: B (Not more than 30 minutes from the abandon ship signal)
💡 Within 30 minutes of the abandon ship signal.
✗
Question 53. What is the role of the designated person ashore under the ISM Code?
Your Answer: (Not answered)
Correct Answer: D (To provide a direct link between the company and those on board, monitoring safety and pollution prevention)
💡 ISM Code 4 requires the company to designate a person ashore providing a direct link with the ship and monitoring safety and pollution prevention. Command remains with the master.
✗
Question 54. What is required when comparing radar and AIS targets?
Your Answer: (Not answered)
Correct Answer: D (Compare the targets shown and establish the cause of any inconsistency, such as incorrect AIS data or radar shadowing)
💡 Where radar and AIS show different targets, such as an AIS target with no radar echo or a large positional difference, the cause should be established: an AIS data entry error, a target without AIS, radar shadowing or a false echo. Verifying promptly avoids a wrong appreciation.
✗
Question 55. What do SOLAS and the related standards require for the pressure containers of a fixed CO2 system?
Your Answer: (Not answered)
Correct Answer: B (Containers must be tested with capacity, charge and test date marked, and checked periodically)
💡 SOLAS and the pressure vessel standards require CO2 cylinders to be tested and clearly marked with charge and test date, and to be checked periodically for weight and pressure, since slow leakage leaves less agent than required.
✗
Question 56. What fire detection arrangement is required for category A machinery spaces?
Your Answer: (Not answered)
Correct Answer: A (A fixed fire detection and fire alarm system capable of detecting a fire and indicating its location)
💡 SOLAS II-2/7 requires a fixed fire detection and alarm system in category A machinery spaces, giving early detection and indicating the location on the bridge or at a control station.
✗
Question 57. What is required of watertight doors during navigation?
Your Answer: (Not answered)
Correct Answer: B (Kept closed, opened only for necessary passage)
💡 SOLAS II-1/22: watertight doors shall be kept closed during navigation, opened only for passage.
✗
Question 58. What is the maximum extension the Administration may grant to an expired certificate?
Your Answer: (Not answered)
Correct Answer: B (5 months)
💡 An extension of not more than 5 months may be granted.
✗
Question 59. What is required for testing the emergency lighting system?
Your Answer: (Not answered)
Correct Answer: A (Periodic testing of automatic operation and duration, with records kept)
💡 SOLAS and good practice require periodic testing of the automatic operation of the emergency lighting and of its duration, for example by simulating failure of the main source, observing the lighting come on and timing it, verifying the prescribed period with records kept, preventing failure during an actual blackout.
✗
Question 60. What is required for lubrication and maintenance of launching appliances?
Your Answer: (Not answered)
Correct Answer: B (Periodic lubrication of moving parts and checking of sheave and pin wear as the manufacturer requires, with records kept)
💡 SOLAS requires periodic lubrication of the moving parts of launching appliances and checking of sheave and pin wear and freedom of movement as the manufacturer's instructions require, with maintenance recorded. Lack of maintenance leaves the appliance liable to seize or fail in an emergency.
✗
Question 61. Each lifeboat shall be provided with equipment including:
Your Answer: (Not answered)
Correct Answer: B (a complete set including oars, compass, sea anchor, first-aid kit, etc.)
💡 SOLAS III/34 lists lifeboat equipment including oars, compass, sea anchor, first-aid kit, food and water.
✗
Question 62. In which circumstances must the officer of the watch notify the master immediately?
Your Answer: (Not answered)
Correct Answer: B (In restricted visibility, on failure of machinery or steering gear, or on encountering a hazard to safety)
💡 STCW and SOLAS require the officer of the watch to call the master immediately in restricted visibility, on failure of machinery or steering gear, or on encountering anything that may endanger safety, or when in doubt.
✗
Question 63. A ship carries 11 passengers plus one infant under one year of age. Under SOLAS I/2, is she a passenger ship?
Your Answer: (Not answered)
Correct Answer: B (No, persons under one year are excluded)
💡 SOLAS I/2 excludes persons under one year of age from the definition of 'passenger'. With 11 passengers the threshold of 12 is not met.
✗
Question 64. What does SOLAS address regarding surface materials on bulkheads in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: A (They must restrict flame spread and meet the prescribed requirements for non-combustibility and low flame spread)
💡 SOLAS II-2 prescribes requirements for non-combustibility and low flame spread for the surfaces of bulkheads, ceilings and linings, preventing rapid spread of flame over surfaces. The materials must be approved.
✗
Question 65. What do SOLAS and good practice address for periods when the machinery space is unattended?
Your Answer: (Not answered)
Correct Answer: B (Alarms must reliably reach the duty engineer and the bridge, with periodic rounds maintained)
💡 During unattended periods the alarm system must work reliably and transmit alarms to the engineers' accommodation or the bridge, with periodic rounds maintained so that machinery abnormalities are detected promptly. A failed alarm system is a serious deficiency.
✗
Question 66. What is the minimum requirement for electronic position fixing equipment under SOLAS V/19?
Your Answer: (Not answered)
Correct Answer: B (It must be capable of receiving signals from at least one terrestrial radio navigation system or satellite navigation system)
💡 SOLAS V/19 requires equipment capable of receiving signals from at least one terrestrial radio navigation system or satellite navigation system. Visual fixing or chart plotting alone does not satisfy the requirement.
✗
Question 67. A PSC inspection found the AIS switched off throughout the voyage. On what basis is this a deficiency?
Your Answer: (Not answered)
Correct Answer: C (AIS must remain in operation and may be switched off only where the master considers this necessary for safety or security)
💡 SOLAS V/19.2.10 requires AIS to remain in operation. It may be switched off only where the master believes its operation might compromise safety or security, with the reason and period recorded in the log. Leaving it off without justification is a deficiency.
✗
Question 68. What is the responsibility of the GMDSS radio operator on board?
Your Answer: (Not answered)
Correct Answer: C (Distress, urgency and safety communications, with watchkeeping and recording as required)
💡 Under SOLAS IV and STCW, the holder of a GMDSS certificate is responsible for distress, urgency and safety communications and watchkeeping, and handles public correspondence under the master's authority.
✗
Question 69. The recording device of an inert gas system may record:
Your Answer: (Not answered)
Correct Answer: B (oxygen content, gas pressure and time)
💡 SOLAS II-2/5 requires continuous recording of oxygen content, gas pressure and time.
✗
Question 70. For a ship with no emergency generator, for how long shall the GMDSS reserve source of energy supply?
Your Answer: (Not answered)
Correct Answer: C (6 hours)
💡 SOLAS IV/13: the reserve source shall be capable of supplying for 6 hours on ships without an emergency generator.
✗
Question 71. What material shall be used for fuel oil piping and fittings?
Your Answer: (Not answered)
Correct Answer: B (Steel or other approved material, securely connected)
💡 Steel or approved material with secure connections shall be used.
✗
Question 72. How must new regulations and circulars be implemented?
Your Answer: (Not answered)
Correct Answer: D (Obtain and assess their effect on the ship promptly, implement the measures and train the crew)
💡 The ISM system requires the ship to obtain new regulations, flag State notices and company circulars promptly, assess their actual effect on the ship, covering equipment, procedures, training and records, implement the necessary measures and brief and train the crew, keeping the ship in compliance with the latest requirements.
✗
Question 73. Which persons are not counted as passengers under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (Children under one year of age)
💡 Children under one year of age are not counted.
✗
Question 74. How is agreement between what is written and what is done verified?
Your Answer: (Not answered)
Correct Answer: B (comparing practice against the document item by item at set intervals, and where they disagree finding the cause: weak training or supervision where the practice is at fault, a document change where the document is wrong)
💡 The comparison is made at intervals through internal audit, ship visits and day to day supervision, and it looks at movements rather than forms: if the document says a lifejacket on boarding, whether anyone skips it; if it says the engine tested before passing alongside, whether the time in the record stands up. A disagreement has to be put in one of two boxes - where execution falls short, training and supervision are tightened and a non-conformity raised if needed; where the document simply does not match reality, it is revised and the revision comes back to the ship, or the two stay apart. Doing it in a heap before each audit leaves the system permanently detached from practice.
✗
Question 75. Which is NOT a function of the GMDSS?
Your Answer: (Not answered)
Correct Answer: A (Commercial advertising)
💡 The GMDSS does not provide commercial advertising.
✗
Question 76. What does SOLAS address regarding the location of the main switchboard?
Your Answer: (Not answered)
Correct Answer: D (Located where it is accessible and protected from water, oil and fire, with appropriate guarding)
💡 SOLAS requires the main switchboard to be located where it is accessible, well ventilated and protected from water, oil and fire, with protective measures such as insulating mats in front, ensuring safe operation and reliable supply.
✗
Question 77. How does the survey programme change as a bulk carrier ages under SOLAS and the ESP?
Your Answer: (Not answered)
Correct Answer: D (The scope and frequency increase with age, particularly close-up survey and thickness measurement)
💡 The ESP prescribes the survey scope by age band, requiring more as the ship grows older, including wider close-up survey and thickness measurement, to assess corrosion and fatigue and decide on repair or reinforcement.
✗
Question 78. Navigation equipment shall be capable of operating:
Your Answer: (Not answered)
Correct Answer: C (with an independent supply if the main and emergency sources fail)
💡 SOLAS V/19: navigation equipment shall have an independent supply where the main and emergency sources of electrical power fail.
✗
Question 79. What does SOLAS address regarding the remote control system of the main engine?
Your Answer: (Not answered)
Correct Answer: C (The main engine must be controllable from the bridge and the machinery control room, with reliable transfer between positions with indication and alarms)
💡 SOLAS requires the main engine to be controllable from both the bridge and the machinery control room, with reliable transfer between control positions and appropriate indication and alarms, preventing loss of control or misoperation during transfer.
✗
Question 80. What should be checked on hatch covers before loading a bulk carrier?
Your Answer: (Not answered)
Correct Answer: C (That the seals, cleats and drain channels are sound, with a hose test to verify watertightness if necessary)
💡 Before loading, the hatch cover seals should be checked for ageing or damage, the cleats for completeness and effectiveness and the drain channels and non-return devices for clearance, with a hose test to verify watertightness where necessary. Hatch cover failure is the principal cause of flooding in bulk carriers.
✗
Question 81. What does SOLAS address regarding product certification of life-saving appliances?
Your Answer: (Not answered)
Correct Answer: C (Appliances must hold type approval or product certificates from a recognised body attesting compliance with the performance standards)
💡 SOLAS requires life-saving appliances to comply with the performance standards such as the LSA Code and to hold type approval or product certificates. Approval marks and certificates are checked at survey and PSC, and equipment without an approval mark may not be accepted.
✗
Question 82. What does 'Company' mean in SOLAS?
Your Answer: (Not answered)
Correct Answer: A (The shipowner or an organization which has assumed responsibility for operation)
💡 It means the owner or any organization which has assumed responsibility for the ship's operation.
✗
Question 83. What are the requirements for managing notices to mariners on board?
Your Answer: (Not answered)
Correct Answer: D (Received and processed promptly, with charts and publications corrected and a record of corrections kept)
💡 SOLAS requires notices to mariners to be received continuously and used to correct charts and publications promptly, with a record kept. Accumulating them uncorrected or merely receiving them makes the charts unreliable.
✗
Question 84. What is required for electrical equipment in areas of machinery spaces where flammable gas may accumulate?
Your Answer: (Not answered)
Correct Answer: B (Explosion-protected equipment or effective ventilation with gas detection, preventing ignition by electrical sparks)
💡 In spaces such as purifier rooms and fuel pump rooms where flammable gas may accumulate, explosion-protected equipment or effective ventilation with gas detection is required, preventing an electrical spark from becoming a source of ignition.
✗
Question 85. An escape route in the engine room is found permanently blocked by stores. The finding is?
Your Answer: (Not answered)
Correct Answer: C (Escape routes must be kept clear; blockage seriously affects emergency evacuation, a serious deficiency)
💡 A machinery space should have two escape routes as widely separated as practicable, always available. A blocked escape route endangers the evacuation of engine room personnel in a fire or other emergency. It is a serious deficiency affecting personnel safety and the obstruction should be removed at once.
✗
Question 86. How do statutory certificates and surveys stand in relation to each other?
Your Answer: (Not answered)
Correct Answer: D (certificates rest on the prescribed surveys being completed and endorsed; annual, intermediate or renewal surveys overdue void them)
💡 Chapter I treats a certificate as the outcome of survey rather than a status held once and for all: an initial survey issues it, annual, intermediate and renewal surveys are completed and endorsed on it, and an overdue survey voids it, so trading on a lapsed endorsement is non-compliance. Extension of a certificate is hedged by conditions and a maximum period; the class of a hull or a survey report does not stand in its place.
✗
Question 87. The purpose of an inclining experiment is to:
Your Answer: (Not answered)
Correct Answer: B (determine the ship's stability elements such as the position of the centre of gravity)
💡 SOLAS II-1/5 requires an inclining experiment to determine stability elements for the master's stability information.
✗
Question 88. Which statement about the application of SOLAS Chapter III is correct?
Your Answer: (Not answered)
Correct Answer: C (It applies to life-saving appliances and arrangements for all ships to which the Convention applies)
💡 SOLAS Chapter III applies to life-saving appliances and arrangements for all ships covered by the Convention, with additional requirements for passenger ships, cargo ships and tankers.
✗
Question 89. What should be noted when using the echo sounder to monitor under-keel clearance?
Your Answer: (Not answered)
Correct Answer: B (Use it with draught and tidal information, remembering that readings are affected by aeration under the hull and the nature of the seabed)
💡 Echo sounder readings may be affected by aeration beneath the hull, water temperature and salinity and the nature of the seabed, and give the depth below the ship. They must be used with the draught, tide and chart to judge under-keel clearance, and a shoal area must not be entered on the strength of the sounder alone.
✗
Question 90. For a passenger ship, within what time after a loss of propulsion shall the ship be able to restore propulsion?
Your Answer: (Not answered)
Correct Answer: A (30 minutes)
💡 SOLAS II-1/26: passenger ships shall restore propulsion within 30 minutes of a dead-ship condition.
✗
Question 91. What is the purpose of the emergency source of electrical power?
Your Answer: (Not answered)
Correct Answer: A (To supply essential services such as emergency lighting, communications and steering when the main source fails)
💡 The emergency source supplies essential safety services when the main source fails, maintaining lighting, communication and steering capability. It is not intended to replace the main source for extended operation.
✗
Question 92. What arrangements does SOLAS permit to ensure the availability of radio equipment in sea areas A1 and A2?
Your Answer: (Not answered)
Correct Answer: A (Duplication of equipment, a shore-based maintenance agreement, or at-sea maintenance capability — one of the three)
💡 SOLAS IV/15 allows availability to be ensured by duplication of equipment, a shore-based maintenance contract or at-sea maintenance capability, used singly or in combination.
✗
Question 93. To which new bulk carriers does the double side skin requirement apply?
Your Answer: (Not answered)
Correct Answer: C (a new single-side-skin bulk carrier of 150 m and up carrying solid bulk of a density of 1000 kg/m3 and above)
💡 The requirement addresses new single-side-skin bulk carriers of 150 m and over intended to carry solid bulk cargoes of a density of 1000 kg/m3 and above, the inner skin being supported by the double side when cargo is discharged and in the event of damage; it does not apply to every bulk carrier. Chapter XII carries other structural requirements taking 100 m as their threshold, the two lengths covering different things, and running them together is the commonest error; the numbering and scope of the provisions have been revised, so the text carried on board governs, and this item makes no reference to a particular sub-regulation. Both the length and the density must be met, so "any bulk carrier" and "the cargo decides" alike fail.
✗
Question 94. What calibration is required for portable gas detectors?
Your Answer: (Not answered)
Correct Answer: C (Calibrated at the prescribed intervals with a functional test before each use and records kept)
💡 SOLAS and the manufacturers require portable gas detectors to be calibrated at the prescribed intervals, normally not exceeding 12 months, with a functional test including zero and span checks before each use and records kept. Readings from an uncalibrated instrument cannot be trusted, and a wrong appreciation can be fatal.
✗
Question 95. What are the key points of the monthly inspection of survival craft launching appliances?
Your Answer: (Not answered)
Correct Answer: B (Check the brake, release gear, falls and sheaves and the securing arrangements for operation and condition)
💡 SOLAS III/20 requires a monthly inspection of the launching appliances of survival craft: checking that the brake holds reliably, the release gear operates correctly, the falls and sheaves are free of broken wires and wear and the securing arrangements release properly, with any defects found and the action taken recorded.
✗
Question 96. The isolating valve on the fire main serving the accommodation side has long been seized and cannot be operated. How should this be judged?
Your Answer: (Not answered)
Correct Answer: D (Fire main isolating valves must be operable at all times; being seized is a deficiency affecting the isolating function)
💡 Isolating valves on the fire main are used to isolate a damaged section of piping so that the rest of the system still receives water. They must be capable of manual operation at all times. Being seized deprives them of their isolating function and is a deficiency affecting the reliability of the firefighting system, which should be rectified.
✗
Question 97. A PSCO checked the continuous synopsis record against the ship's history. What changes must the CSR record?
Your Answer: (Not answered)
Correct Answer: D (Significant events such as changes of name, flag, company, recognised organisation and class)
💡 SOLAS XI-1/5 requires the CSR to record the ship's history and significant changes, including changes of name, flag, company, recognised organisation and class, so the record is traceable. Incomplete or out-of-date entries are a deficiency.
✗
Question 98. What does SOLAS address regarding sounding pipes?
Your Answer: (Not answered)
Correct Answer: A (They must reach the bottom of the tank with reliable closing appliances, positioned for easy sounding without impairing watertightness)
💡 SOLAS requires sounding pipes to reach the bottom of the tank for accurate measurement, with reliable closing appliances, positioned for convenient sounding without impairing watertightness or safety. Pipes passing through accommodation spaces require particular care to prevent escape of vapour.
✗
Question 99. What are the requirements for keeping a radio log?
Your Answer: (Not answered)
Correct Answer: C (Distress, urgency and safety communications and equipment tests must be recorded as required)
💡 SOLAS IV/17 requires a radio log recording distress and safety communications, equipment tests and significant events, for use at surveys and in casualty investigation.
✗
Question 100. What maintenance does the radar antenna and waveguide require?
Your Answer: (Not answered)
Correct Answer: A (Check that the antenna rotates freely, that the waveguide is not damp or damaged and that the antenna is not obstructed)
💡 Radar requires periodic checking that the antenna turning gear is free, that the waveguide and joints are not damp, damaged or waterlogged and that no new structure such as a mast or antenna obstructs the antenna, with performance checks as prescribed, keeping the detection capability of the radar.