Question 1. What emergency preparedness is required while the ship is at anchor?
Your Answer: (Not answered)
Correct Answer: A (The emergency organisation and equipment must remain available, with the ship's condition monitored under the anchor watch)
💡 At anchor the emergency organisation must remain effective and emergency equipment such as survival craft, firefighting appliances and emergency communications available, with the position, weather and surroundings monitored under the anchor watch, ready at all times to respond to the unexpected.
✗
Question 2. What are the key points in checking the falls of a launching appliance?
Your Answer: (Not answered)
Correct Answer: C (Check for broken wires, corrosion, deformation and the security of the terminations, replacing when beyond the limit)
💡 The falls of a launching appliance should be checked for the number of broken wires, corrosion, kinks and deformation and for the security of the terminations, replaced at once when beyond the rejection criteria. Failure of the falls would drop the craft during launching with fatal consequences.
✗
Question 3. In restricted visibility, the look-out shall use:
Your Answer: (Not answered)
Correct Answer: C (Sight, hearing and all available means appropriate to the circumstances)
💡 SOLAS V/30: in restricted visibility all available means appropriate to the circumstances shall be used.
✗
Question 4. What safety requirements apply to compressed air systems?
Your Answer: (Not answered)
Correct Answer: D (Safety valves and drains, preventing accumulation of oil causing explosion, with piping pressure rated and inspected periodically)
💡 SOLAS and good practice require compressed air systems to have safety valves and drains, with condensate and oil removed periodically, preventing overpressure of receivers and piping and accumulation of oil which can cause an explosion, a common cause of scavenge box explosions, with the piping and fittings inspected periodically.
✗
Question 5. What is the requirement for the stowage of lifebuoys?
Your Answer: (Not answered)
Correct Answer: D (They must be readily available, normally distributed on both sides and near survival craft muster stations)
💡 SOLAS requires lifebuoys to be readily available, distributed on both sides and near muster stations. Central stowage delays the rescue of a person overboard.
✗
Question 6. To which ship types does the Enhanced Programme of Inspections apply?
Your Answer: (Not answered)
Correct Answer: C (Oil tankers and bulk carriers)
💡 SOLAS XI-1/2 applies the enhanced programme of inspections to oil tankers and bulk carriers, imposing stricter survey requirements on these higher-risk ship types. It does not apply to all ships.
✗
Question 7. In which spaces must ceilings and linings be of non-combustible material?
Your Answer: (Not answered)
Correct Answer: A (In enclosures of stairways and corridors forming escape routes)
💡 SOLAS requires non-combustible linings and ceilings in critical spaces such as stairway enclosures and corridors serving as escape routes, limiting the spread of fire and keeping the escape route safe.
✗
Question 8. Which statement about the changeover to emergency steering is correct?
Your Answer: (Not answered)
Correct Answer: B (Emergency steering should be possible in the steering gear space or at an alternative position, and the crew should be familiar with the operating and communication procedures)
💡 Under SOLAS II-1/29 and the operational requirements emergency steering should be possible in the steering gear space or at a designated alternative position, with communication to the bridge by direct telephone or as required. The crew should become familiar with the changeover and steering procedures through emergency steering drills, and test records should be retained.
✗
Question 9. What do SOLAS and the related rules emphasise for position fixing in ice or polar waters?
Your Answer: (Not answered)
Correct Answer: A (Cross-check by several means, since compass and position fixing equipment may be affected by magnetic variation and signal conditions in polar regions)
💡 Magnetic variation is large in polar regions and satellite signals may be affected by ionospheric conditions. SOLAS and good seamanship require the position and heading to be cross-checked by several means, avoiding the risk from a single equipment error.
✗
Question 10. B class divisions shall be capable of withstanding a standard fire test for:
Your Answer: (Not answered)
Correct Answer: B (30 minutes)
💡 SOLAS II-2/3 requires B class divisions to withstand a standard fire test for 30 minutes.
✗
Question 11. What is the responsibility of the GMDSS radio operator on board?
Your Answer: (Not answered)
Correct Answer: C (Distress, urgency and safety communications, with watchkeeping and recording as required)
💡 Under SOLAS IV and STCW, the holder of a GMDSS certificate is responsible for distress, urgency and safety communications and watchkeeping, and handles public correspondence under the master's authority.
✗
Question 12. Where shall the collision bulkhead be fitted and why?
Your Answer: (Not answered)
Correct Answer: B (Forward, to confine flooding from bow damage)
💡 The collision bulkhead limits flooding to the forward region after a collision.
✗
Question 13. Where a certificate expires and the ship is not in a port of survey, the Administration may extend the certificate for a period not exceeding:
Your Answer: (Not answered)
Correct Answer: A (5 months)
💡 SOLAS I/14: where a ship is not in a port of survey at expiry, the Administration may extend the certificate for a period not exceeding 5 months.
✗
Question 14. What is the purpose of the line-throwing appliance among life-saving appliances?
Your Answer: (Not answered)
Correct Answer: A (To throw a line over a required distance so that contact can be established with another ship or the shore)
💡 SOLAS requires a line-throwing appliance capable of throwing a line over a prescribed distance, normally not less than 230 m, to establish contact with a casualty or the shore.
✗
Question 15. What does the requirement for course and position recording equipment under SOLAS V/19 address?
Your Answer: (Not answered)
Correct Answer: B (Recording position and heading so that they can be checked afterwards and used in investigation)
💡 SOLAS requires equipment such as a VDR or equivalent capable of recording position and heading, providing evidence for casualty investigation and voyage review.
✗
Question 16. What is required regarding VHF channel 16 watchkeeping?
Your Answer: (Not answered)
Correct Answer: A (Continuous watch while under way)
💡 A continuous watch on VHF channel 16 shall be kept while under way.
✗
Question 17. What is the requirement for testing life-saving appliances?
Your Answer: (Not answered)
Correct Answer: C (They shall be examined and tested at prescribed intervals)
💡 All life-saving appliances shall be examined and tested at the prescribed intervals.
✗
Question 18. The muster list shall specify:
Your Answer: (Not answered)
Correct Answer: A (the duties, stations and emergency signals for each person)
💡 SOLAS III/37 requires the muster list to specify the duties and stations of each person and the emergency signals.
✗
Question 19. Besides the ship, where else shall life-saving appliances be provided?
Your Answer: (Not answered)
Correct Answer: A (One full set at the shore establishment)
💡 A full set shall also be kept at the shore establishment.
✗
Question 20. What must the navigational safety measures for polar waters include?
Your Answer: (Not answered)
Correct Answer: D (A voyage plan taking account of ice conditions, visibility and the ship's capabilities, with action to be taken if they are exceeded)
💡 The Polar Code requires the voyage plan for polar waters to consider ice conditions, visibility, the ship's ice class capability and the experience of the crew, and to state the action to be taken if conditions exceed the ship's capabilities, such as altering course or stopping.
✗
Question 21. Cargo ships of 1 000 GT and above shall be provided with at least how many independently driven fire pumps?
Your Answer: (Not answered)
Correct Answer: D (2)
💡 SOLAS II-2/10 requires at least two independently driven fire pumps for cargo ships of 1 000 GT and above.
✗
Question 22. What is the purpose of self-closing doors on escape routes?
Your Answer: (Not answered)
Correct Answer: B (To block the spread of smoke and flame)
💡 They block smoke and flame from spreading.
✗
Question 23. What do SOLAS and good practice address regarding the inspection of the propulsion shafting?
Your Answer: (Not answered)
Correct Answer: A (Periodic inspection of the tail shaft, intermediate shaft and bearings for wear, sealing and alignment)
💡 SOLAS and the classification societies require periodic inspection of the propulsion shafting for stern tube sealing, bearing wear and alignment, detecting abnormalities that could cause oil leakage, vibration or shaft failure with loss of propulsion.
✗
Question 24. For how long must the GMDSS reserve source of energy supply the radio installation when the main source fails under SOLAS IV/9?
Your Answer: (Not answered)
Correct Answer: C (At least one hour, for both passenger and cargo ships)
💡 SOLAS IV/9 requires the reserve source to supply the radio installation for at least one hour. The 18-hour figure applies to emergency lighting on cargo ships under a different regulation.
✗
Question 25. What is the required interval for emergency steering drills?
Your Answer: (Not answered)
Correct Answer: C (At least once every three months)
💡 Under SOLAS III/19 emergency steering drills should be held at least once every three months. The drill makes the crew familiar with the procedures and communications for changing to the emergency steering gear when the main steering fails, and is a key emergency preparedness item.
✗
Question 26. How long must dangerous goods documentation be kept on board?
Your Answer: (Not answered)
Correct Answer: A (For the prescribed period, normally until some time after discharge at the port of destination, for traceability and investigation)
💡 The documentation for dangerous goods, the manifest, stowage plan and special cargo information, must be retained for the prescribed period, normally until a certain time after discharge at the port of destination depending on the rules, so that the nature and stowage of the goods can be traced in the event of an incident or pollution.
✗
Question 27. What does SOLAS address regarding fuel for lifeboat engines?
Your Answer: (Not answered)
Correct Answer: B (Fuel with a flashpoint of not less than 43 degrees Celsius, and tank capacity allowing the boat to run at the prescribed speed for a specified time)
💡 SOLAS requires lifeboat engines to use fuel with a flashpoint of not less than 43 degrees Celsius, reducing fire risk, and a tank capacity allowing the boat to run at the prescribed speed for a specified period, ensuring mobility after abandonment.
✗
Question 28. What separation is required between accommodation spaces and a stairway enclosure?
Your Answer: (Not answered)
Correct Answer: A (The enclosure must be separated from the accommodation by class A divisions with fire doors at openings)
💡 SOLAS requires a stairway enclosure to be separated from accommodation spaces by class A divisions with fire doors of the same rating at the openings, preventing fire from spreading upwards through the stairway. Stairways are the principal path for vertical spread and inadequate separation has serious consequences.
✗
Question 29. What minimum speed must a powered rescue boat be capable of maintaining in calm water with its full complement aboard?
Your Answer: (Not answered)
Correct Answer: B (6 knots)
💡 SOLAS III/17 requires a powered rescue boat to maintain at least 6 knots for not less than 4 hours. Four knots is a frequently confused figure.
✗
Question 30. What calibration is required for portable gas detectors?
Your Answer: (Not answered)
Correct Answer: C (Calibrated at the prescribed intervals with a functional test before each use and records kept)
💡 SOLAS and the manufacturers require portable gas detectors to be calibrated at the prescribed intervals, normally not exceeding 12 months, with a functional test including zero and span checks before each use and records kept. Readings from an uncalibrated instrument cannot be trusted, and a wrong appreciation can be fatal.
✗
Question 31. When the ship security level is raised from level 1 to level 2, what should be done?
Your Answer: (Not answered)
Correct Answer: D (Enhanced security measures should be applied under the approved ship security plan, such as tighter access control, surveillance and checking of persons)
💡 When the security level is raised the ship should apply enhanced security measures under the approved ship security plan, such as restricted access, closer surveillance of decks and sides, checking of persons and goods and controlling passages and lighting. The master may request a higher level for local conditions.
✗
Question 32. A PSCO checked the escape arrangements from a category A machinery space. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: D (Two means of escape distant from each other, one of which may be an enclosed route)
💡 SOLAS II-2/13 requires two means of escape from a category A machinery space, remote from each other, normally two steel ladders one of which may be enclosed, so that one remains usable if the other is blocked by fire or smoke.
✗
Question 33. What do COLREG and SOLAS require for overtaking in a narrow channel?
Your Answer: (Not answered)
Correct Answer: D (The overtaking vessel must obtain the agreement of the vessel being overtaken and keep a sufficient distance)
💡 COLREG Rule 9 requires a vessel intending to overtake in a narrow channel to obtain the agreement of the vessel to be overtaken, normally by VHF or sound signal, and to pass at a sufficient distance. Overtaking without agreement risks collision.
✗
Question 34. How must operating instructions and markings for equipment be managed?
Your Answer: (Not answered)
Correct Answer: B (Clear instructions and warnings, available near the equipment and kept in good condition)
💡 Operating instructions and warning markings for critical equipment should be provided near the equipment, clear and in good condition, not fallen off or illegible, so that the operator can consult them at any time. Relying on memory without markings makes errors likely after a change of personnel or under pressure.
✗
Question 35. What does the Polar Code require regarding life-saving appliances in polar waters?
Your Answer: (Not answered)
Correct Answer: C (They must work at low temperature, with measures to extend survival time in the polar environment)
💡 The Polar Code requires life-saving appliances to function at low temperature and for measures to extend survival time, such as additional thermal protection, collective survival equipment and search aids.
✗
Question 36. What should be done after a water ingress alarm on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (Identify the flooded hold, assess the effect on stability and strength and take measures such as pumping or adjustment, reporting as required)
💡 On a water ingress alarm the flooded hold and the cause should be established at once, such as hatch leakage, hull damage or piping leakage, the effect on stability, strength and draught assessed and measures taken such as pumping, adjusting ballast or reducing cargo, with the company and the Administration informed under the SMS.
✗
Question 37. What protection is required when handling corrosive cargo on a chemical tanker?
Your Answer: (Not answered)
Correct Answer: C (Appropriate protective equipment such as acid-resistant gloves, face protection and protective clothing, with washing facilities available)
💡 SOLAS and the IBC Code require appropriate personal protective equipment for handling corrosive or toxic chemicals, such as resistant gloves, face and eye protection and protective clothing, with emergency washing facilities available for prompt treatment on contact. The ship should carry her own protective equipment.
✗
Question 38. What language does SOLAS require for life-saving appliance markings?
Your Answer: (Not answered)
Correct Answer: C (The working language of the ship or English, with operating illustrations)
💡 SOLAS requires markings and instructions on life-saving appliances to be in the working language of the ship or in English, with illustrations, so that seafarers of different nationalities can understand them.
✗
Question 39. What do the blind sector limitations of SOLAS V/22 principally concern?
Your Answer: (Not answered)
Correct Answer: A (The total arc and individual arcs of blind sectors ahead as seen from the conning position)
💡 SOLAS V/22 limits the number and total arc of blind sectors ahead from the conning position so that the look-out remains effective. It does not deal with radar shadows or window reflection.
✗
Question 40. What is required for the maintenance of water ingress detectors on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: B (Tested at regular intervals and kept operational, with tests and maintenance recorded)
💡 SOLAS requires the water ingress detection system of a bulk carrier to be tested and maintained at regular intervals with records kept, so that it alarms reliably when flooding occurs. Long neglect of testing means the system may fail unnoticed.
✗
Question 41. What is the essential requirement of SOLAS II-2/9 for fire doors?
Your Answer: (Not answered)
Correct Answer: B (They must maintain the fire integrity of the division and close reliably in the event of fire)
💡 SOLAS II-2/9 requires fire doors to preserve the rating of the division and to close in a fire by self-closing means or remote control. Securing them permanently open is a common deficiency.
✗
Question 42. What information must drill records contain under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (The date, the type and scenario of the drill, the craft and equipment used, the persons taking part and any defects found)
💡 SOLAS requires drill records to include the date, the scenario, the craft and equipment used, the persons taking part and any problems found with the action taken, enabling a surveyor to judge whether the drills were genuine and effective.
✗
Question 43. How should a lifeboat be launched?
Your Answer: (Not answered)
Correct Answer: D (Controlled from within the boat (gravity davit) with the lowering speed controlled and the boat kept steady)
💡 A lifeboat is launched under control from within the boat, with a release arrangement in the boat for a gravity davit. The lowering speed should be controlled, contact with the ship's side prevented and the boat turned and cleared for release before entering the water. Too fast a descent causes casualties and structural damage.
✗
Question 44. For a cargo ship with a double bottom, the minimum height of the inner bottom above the top of the keel at midships shall be:
Your Answer: (Not answered)
Correct Answer: D (B/20 or 2 m, whichever is less)
💡 SOLAS II-1/6: the double bottom height shall be not less than B/20 and in no case less than 760 mm; in machinery spaces it may be reduced to B/20 or 2 m, whichever is less.
✗
Question 45. Internal safety audits under the ISM Code shall be carried out:
Your Answer: (Not answered)
Correct Answer: B (at least annually)
💡 SOLAS IX/5: internal safety audits shall be carried out at least annually.
✗
Question 46. What problem may an excessive initial metacentric height cause?
Your Answer: (Not answered)
Correct Answer: C (A short rolling period and violent rolling, which may shift cargo or injure personnel)
💡 An excessive initial metacentric height produces a short rolling period and violent rolling, a stiff ship, which can shift cargo and equipment, injure personnel and increase structural stresses. More stability is not always better; it should be within a reasonable range.
✗
Question 47. Segregation is required when dangerous goods are stowed on board. What is the fundamental purpose?
Your Answer: (Not answered)
Correct Answer: B (To prevent incompatible substances reacting dangerously on contact)
💡 Segregation under SOLAS VII/3 and the IMDG Code prevents incompatible substances from reacting if released, causing fire, explosion or toxic gas. It is not a tallying convenience.
✗
Question 48. What is required regarding the composition of the navigational watch?
Your Answer: (Not answered)
Correct Answer: A (Sufficient officers, look-outs and helmsmen according to visibility, traffic density, trading area and the ship's condition)
💡 STCW and SOLAS require sufficient personnel for the navigational watch, officers, look-outs and helmsmen, according to visibility, traffic density, the characteristics of the area, the condition of the ship's equipment and the demands of the operation. A single-handed watch does not satisfy the requirement in most circumstances.
✗
Question 49. From what tonnage shall a gyro compass be fitted?
Your Answer: (Not answered)
Correct Answer: A (150 GT and above)
💡 150 GT and above on international voyages.
✗
Question 50. What is the main purpose of ship reporting systems?
Your Answer: (Not answered)
Correct Answer: A (To provide information on ship movements for search and rescue and safety of navigation)
💡 SOLAS V/11 establishes ship reporting systems to supply movement information for search and rescue and safety of navigation, not for commercial or charging purposes.
✗
Question 51. A Passenger Ship Safety Certificate shall be issued for a period not exceeding:
Your Answer: (Not answered)
Correct Answer: D (12 months)
💡 SOLAS I/12: a Passenger Ship Safety Certificate shall be issued for a period not exceeding 12 months.
✗
Question 52. An owner asks which statutory surveys a cargo ship safety radio certificate requires. Which combination is correct?
Your Answer: (Not answered)
Correct Answer: C (Initial, annual and renewal surveys)
💡 The cargo ship safety radio certificate requires initial, annual and renewal surveys. The intermediate survey applies to the safety equipment and safety construction certificates.
✗
Question 53. What is the main value of combining radar with ARPA?
Your Answer: (Not answered)
Correct Answer: C (Automatic tracking and computation of relative motion to assess collision risk)
💡 ARPA tracks targets automatically and computes CPA/TCPA to assess collision risk.
✗
Question 54. A renewal survey shall normally be completed within how long before the expiry of the existing certificate?
Your Answer: (Not answered)
Correct Answer: B (three months before expiry)
💡 SOLAS I/6: a renewal survey shall normally be completed within three months before the expiry of the existing certificate.
✗
Question 55. What are the security measures at security level 1?
Your Answer: (Not answered)
Correct Answer: B (The minimum protective measures maintained at all times in normal conditions, such as controlling access and monitoring restricted areas)
💡 ISPS Code Part A/12 requires security level 1 to be maintained continuously, including control of access to the ship, monitoring of restricted areas and supervision of persons and cargo embarking. These are the basic measures in normal operation.
✗
Question 56. What protection does SOLAS require for electric and electrohydraulic steering gear?
Your Answer: (Not answered)
Correct Answer: A (Short circuit and overload protection, with an alarm for single phase failure)
💡 SOLAS II-1/30 requires electric and electrohydraulic steering gear to have short circuit and overload protection and to give an alarm in the event of a single phase failure, preventing sudden loss of steering.
✗
Question 57. In a crossing situation, what principle governs the stand-on vessel's action?
Your Answer: (Not answered)
Correct Answer: C (keep course and speed at first; but once it is clear the give-way vessel is not acting as the rules require, take avoiding action alone)
💡 Where one of two vessels is to keep out of the way the other keeps course and speed - not a bar on moving but a predictable target offered to the other. The keeping has a condition: as soon as the stand-on vessel finds the give-way vessel plainly not acting as the rules require, she should act alone in the way best to avoid collision, and a turn to starboard generally serves better than one to port, which would put her across his bow. When collision cannot be avoided by the give-way vessel's action alone, she may depart from the rules. Easing ahead across his bow, doing his keeping-out-of-the-way for him, or stopping on the spot all throw away the predictability.
✗
Question 58. What is required for monitoring and re-entry after releasing a fixed extinguishing system?
Your Answer: (Not answered)
Correct Answer: C (Monitor the boundary temperature of the space to judge the fire, and enter only after cooling, adequate ventilation and satisfactory testing)
💡 After releasing a fixed extinguishing system the boundary temperature of the space should be monitored to judge whether the fire is out and the space kept closed for a sufficient period. Entry is permitted only after the boundary temperature has clearly fallen, adequate ventilation has been carried out and oxygen and harmful gas tests are satisfactory, with breathing apparatus worn.
✗
Question 59. Regarding the emergency fire pump, which statement about its location is correct?
Your Answer: (Not answered)
Correct Answer: B (it shall be located outside the machinery space and its source of power shall also be outside the machinery space)
💡 SOLAS II-2/10 requires the emergency fire pump to be located outside the machinery space with its source of power also outside, to ensure water supply if the machinery space is on fire.
✗
Question 60. What is the significance of the distinction between life-saving appliances and arrangements in SOLAS Chapter III?
Your Answer: (Not answered)
Correct Answer: A (Appliances are items such as survival craft and lifejackets, while arrangements are the boarding, launching, stowage and lighting provisions)
💡 In SOLAS Chapter III, life-saving appliances are items such as craft, lifejackets and equipment, while arrangements refer to the structural provisions for boarding, launching, stowage and lighting. The two attract different points of attention at survey.
✗
Question 61. For a tanker fitted with an inert gas system, the deck foam system application rate shall be not less than:
Your Answer: (Not answered)
Correct Answer: C (1.0 L/min·m²)
💡 SOLAS II-2/20 requires the foam application rate to be not less than 1.0 L/min·m² for tankers with an inert gas system.
✗
Question 62. Insulation was removed from a fire division for work and not replaced. What is the finding?
Your Answer: (Not answered)
Correct Answer: B (A deficiency; missing insulation reduces the fire performance of the division and must be restored promptly)
💡 Insulation removed from a fire division, for example to gain access during work, and not replaced significantly reduces its fire performance, so heat and fire cannot be effectively contained. It is a deficiency affecting safety and must be restored promptly with approved material.
✗
Question 63. A PSC inspection found a lifeboat equipment locker locked with the key not in the boat. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: A (Equipment of survival craft must be ready for immediate use and must not be locked away)
💡 SOLAS requires survival craft equipment to be ready for immediate use. Locking it away or storing it elsewhere means it cannot be reached promptly in an abandonment, contrary to the readiness requirement, and is a deficiency.
✗
Question 64. In a narrow channel, a vessel engaged in fishing shall not impede:
Your Answer: (Not answered)
Correct Answer: A (any other vessel which can navigate only within the narrow channel)
💡 SOLAS V/27: in a narrow channel, a vessel engaged in fishing shall not impede any vessel which can navigate only within that channel.
✗
Question 65. What is the purpose of a compass corrector on board?
Your Answer: (Not answered)
Correct Answer: C (Eliminating residual deviation of the magnetic compass)
💡 A compass corrector compensates for residual deviation caused by the ship's magnetic field.
✗
Question 66. The engine telegraph is used to:
Your Answer: (Not answered)
Correct Answer: C (transmit main engine manoeuvring orders from the bridge to the engine room)
💡 SOLAS II-1/31 requires an engine telegraph for transmitting orders from the bridge to the engine room.
✗
Question 67. How should hazard identification and risk assessment be carried out on board?
Your Answer: (Not answered)
Correct Answer: B (Identify hazards and assess risks for shipboard operations and equipment and take control measures accordingly)
💡 The ISM Code requires hazard identification and risk assessment on board for operations and equipment, covering routine and non-routine work and new equipment and new operations, from which control measures are decided and incorporated into procedures and checklists, bringing risks under control in advance.
✗
Question 68. If the Inmarsat equipment fails while a ship is in sea area A3, what alternative does SOLAS permit?
Your Answer: (Not answered)
Correct Answer: A (Using MF/HF equipment to meet the distress and safety communication requirements)
💡 Where the primary satellite equipment fails, the ship must use MF/HF to maintain distress and safety communication in sea area A3. Reliance on another ship or on repair is not acceptable.
✗
Question 69. Sea area A4 means an area outside sea areas:
Your Answer: (Not answered)
Correct Answer: D (A1, A2 and A3)
💡 SOLAS IV/2: Sea area A4 is the area outside sea areas A1, A2 and A3.
✗
Question 70. The carriage of grain in bulk shall follow:
Your Answer: (Not answered)
Correct Answer: B (the International Grain Code)
💡 SOLAS VI/6: the carriage of grain in bulk shall follow the International Grain Code.
✗
Question 71. Where are firefighter's outfits stowed?
Your Answer: (Not answered)
Correct Answer: B (distributed over two or more readily accessible spots, clearly marked and lit, one still reachable if another is cut off)
💡 One question decides the stowage: can they still be reached when a fire is burning. The positions are to be readily accessible, plainly marked and permanently lighted, and distributed according to the size and layout of the ship so that a fire or a space full of smoke does not put every outfit out of reach. How many outfits, with the breathing sets and spares that go with them, is separately laid down; apart does not mean scattered, and each location must serve on its own. To lock them in a store and fetch the key when the alarm goes, to group them where the watchkeeper sits, to keep them with the paperwork because that is easy to register, all push the moment of use later, and a fire does not wait. The periodic check covers the positions as well: goods stacked in front of them, a dead light, a fallen sign, each makes sound gear unreachable.
✗
Question 72. What does SOLAS emphasise in the launching and recovery of survival craft?
Your Answer: (Not answered)
Correct Answer: A (Operations must be carried out under safe conditions with adequate lighting and by persons familiar with the procedure)
💡 SOLAS requires launching and recovery to be conducted under safe conditions, with adequate lighting, by persons familiar with the procedure and equipment, to avoid casualties during drills.
✗
Question 73. A PSCO checked the permanent markings on the hull. Where must the IMO number be marked under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (Permanently marked on the hull, such as on the stern or side, and internally as required)
💡 SOLAS XI-1/3 requires the IMO ship identification number to be permanently marked on the hull, normally on the stern and sides, and also internally as required, so that the ship can be identified and traced.
✗
Question 74. Which arrangements does SOLAS permit for the survival craft of a cargo ship?
Your Answer: (Not answered)
Correct Answer: C (One or more lifeboats on each side, or a combination of lifeboats and liferafts)
💡 SOLAS III/31 permits arrangements such as lifeboats on each side or a combination of lifeboats and liferafts. Whichever is used, the capacity on each side must accommodate all persons on board.
✗
Question 75. What are the main requirements for air pipes on the freeboard deck?
Your Answer: (Not answered)
Correct Answer: D (Their openings should have effective closing appliances, and the pipes should be so arranged that water cannot enter the tanks when the ship heels)
💡 Air pipes ventilate the tanks and their opening height and closing appliances must meet the requirements, ensuring that in conditions of heeling and boarding seas water cannot enter the tanks and affect stability and liquid management. The closing appliances should be kept effective and closed as required.
✗
Question 76. Which VHF channel is used for distress and safety radiotelephony?
Your Answer: (Not answered)
Correct Answer: A (Channel 16 (156.8 MHz))
💡 VHF channel 16 (156.8 MHz) is for distress and safety radiotelephony. Channel 70 is reserved for DSC calling and must not be used for speech.
✗
Question 77. What is the usual maximum validity of a Cargo Ship Safety Construction Certificate?
Your Answer: (Not answered)
Correct Answer: C (Five years, with annual and intermediate surveys)
💡 Under SOLAS I/12 the Cargo Ship Safety Construction Certificate has a usual validity of not more than five years, with annual and intermediate surveys within it. It remains valid only if the surveys are carried out and endorsed, otherwise it lapses.
✗
Question 78. What time limits apply to work in an enclosed space?
Your Answer: (Not answered)
Correct Answer: D (Work according to the conditions and period in the permit, with re-testing and a new permit if the period expires or conditions change)
💡 SOLAS and the IMO resolutions require work in an enclosed space to be carried out under the conditions and for the period stated in the permit, with ventilation and testing maintained. If the permit period expires, ventilation is interrupted or conditions change, work must stop, the atmosphere be re-tested and a new permit issued.
✗
Question 79. SOLAS requires each ship to be provided with:
Your Answer: (Not answered)
Correct Answer: A (a training manual describing the use of life-saving appliances and survival knowledge)
💡 SOLAS III/35 requires a training manual describing the use of the ship's life-saving appliances and survival knowledge.
✗
Question 80. What do SOLAS and good practice address regarding the hydraulic steering gear?
Your Answer: (Not answered)
Correct Answer: A (Oil level and pressure monitoring with alarms, preventing loss of steering through low oil or loss of pressure)
💡 The hydraulic steering gear should have oil level and pressure monitoring with alarms, detecting oil loss or loss of pressure in good time, since steering failure directly endangers the safe manoeuvring of the ship.
✗
Question 81. What do SOLAS and STCW emphasise about the master's instructions to the officer of the watch?
Your Answer: (Not answered)
Correct Answer: D (The master should issue clear standing and night orders, which the watchkeeper follows, with the orders recorded)
💡 STCW and SOLAS require the master to issue clear standing orders and night orders, normally in writing, which the officer of the watch is familiar with and follows, calling the master immediately in any unforeseen situation.
✗
Question 82. Lifejackets stowed in lockers on deck or at the ship's side are intended to be:
Your Answer: (Not answered)
Correct Answer: A (Easy to don and quickly accessible in an emergency)
💡 Lifejackets shall be easy to don and quickly accessible in an emergency.
✗
Question 83. What does SOLAS address regarding the protection of stairway enclosures?
Your Answer: (Not answered)
Correct Answer: D (Stairways must be enclosed by class A or B divisions, preventing a chimney effect from accelerating fire and smoke spread)
💡 SOLAS requires enclosed stairways in accommodation spaces to be protected by class A or B divisions, preventing the stairwell from acting as a chimney that accelerates the upward spread of flame and smoke, and protecting the escape route.
✗
Question 84. What should be noted about using survival craft at low temperature in polar waters?
Your Answer: (Not answered)
Correct Answer: B (Difficulty in starting engines, reduced battery capacity and changed equipment performance, with insulation and pre-heating measures taken)
💡 Using survival craft in polar conditions requires attention to difficulty in starting engines, addressed by insulation, pre-heating and oil suited to low temperature, reduced battery capacity, addressed by insulation or spares, changed performance of equipment and the risk of hypothermia, with plans and drills in place.
✗
Question 85. What does SOLAS address regarding fire doors in an enclosed escape route?
Your Answer: (Not answered)
Correct Answer: C (Self-closing fire doors must be fitted, maintaining the fire integrity of the route)
💡 SOLAS requires self-closing fire doors in an enclosed escape route, allowing normal passage and closing automatically in a fire to preserve the fire integrity of the route. Ordinary or removed doors destroy that protection.
✗
Question 86. Besides the proper shipping name, what must appear on a dangerous goods document?
Your Answer: (Not answered)
Correct Answer: C (The UN number and the hazard class)
💡 Dangerous goods documents must show the proper shipping name, UN number, class and packing group.
✗
Question 87. What separation is required for the deck between accommodation spaces and a machinery space?
Your Answer: (Not answered)
Correct Answer: A (Normally A-60 class, protecting a high fire risk boundary)
💡 SOLAS requires A-60 class boundaries between category A machinery spaces and accommodation spaces. Because the fire risk in machinery spaces is high, the strongest protection is required to prevent spread to the accommodation.
✗
Question 88. What routine maintenance does the fire main require?
Your Answer: (Not answered)
Correct Answer: A (Periodic checks for corrosion and leakage, freedom of valve operation and prevention of water standing and freezing in the pipe)
💡 The fire main should be checked periodically for corrosion and leakage of the pipe wall and for freedom of valve operation, with standing water prevented from freezing in cold weather and periodic pressure testing, ensuring the system works reliably when needed.
✗
Question 89. What happens to the statutory certificates when a ship changes to a new owner and flag?
Your Answer: (Not answered)
Correct Answer: B (The existing certificates cease to be valid and new ones must be issued by the new flag Administration or its authorised body after survey)
💡 SOLAS requires certificates to be issued by the Administration of the State whose flag the ship is entitled to fly. After a change of flag the existing certificates are no longer valid and new ones must be issued following survey by the new Administration. Using the old certificates is a serious deficiency.
✗
Question 90. Why does SOLAS V/19.2.2 require a heading repeater at the steering position?
Your Answer: (Not answered)
Correct Answer: D (So that the helmsman can read the heading without leaving the steering position)
💡 SOLAS requires a heading repeater at the steering position so the helmsman can read the heading directly without leaving his station.
✗
Question 91. A lifeboat shall be provided with at least how many hand flares?
Your Answer: (Not answered)
Correct Answer: B (6)
💡 SOLAS III/34 requires at least six hand flares in a lifeboat.
✗
Question 92. The ECDIS safety contour and safety depth settings are found not adjusted according to the voyage for a long time. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Safety parameters must be set for each voyage and draught; not adjusting them is an operational deficiency)
💡 Parameters such as the ECDIS safety contour, safety depth and shallow contour should be set sensibly for the water, draught and under-keel clearance of each voyage so that shallow-water and danger alarms work effectively. Leaving them unchanged makes the alarms meaningless. It is an operational deficiency to be corrected.
✗
Question 93. What safety is required for personnel entering a fire?
Your Answer: (Not answered)
Correct Answer: C (Enter in teams of two or more, maintain communication and keep within the air supply of the cylinders, following a known route)
💡 Entry for search and rescue requires teams of two or more, communication maintained with the command and outside, time strictly limited to the air supply of the breathing apparatus with allowance for the return, a known route followed and marked and a lifeline used where necessary. Entry alone and without communication is never permitted.
✗
Question 94. At what stage must the initial survey for statutory certificates be completed?
Your Answer: (Not answered)
Correct Answer: A (Before the ship is put into service)
💡 SOLAS I/7 requires the initial survey to be completed and the certificates obtained before the ship is put into service. Operating without them is a serious breach of the Convention.
✗
Question 95. What do SOLAS V and COLREG require when navigating in a narrow channel?
Your Answer: (Not answered)
Correct Answer: A (Keep as near to the outer limit on the starboard side as is safe and practicable, at a safe speed with an adequate look-out)
💡 COLREG Rule 9 requires a vessel in a narrow channel to keep as near to the outer limit on her starboard side as is safe and practicable, at a safe speed with an adequate look-out. High speed or occupying any part of the channel greatly increases the risk of collision.
✗
Question 96. What does SOLAS address regarding the remote control system of the main engine?
Your Answer: (Not answered)
Correct Answer: C (The main engine must be controllable from the bridge and the machinery control room, with reliable transfer between positions with indication and alarms)
💡 SOLAS requires the main engine to be controllable from both the bridge and the machinery control room, with reliable transfer between control positions and appropriate indication and alarms, preventing loss of control or misoperation during transfer.
✗
Question 97. What is the maximum interval between ship security drills required by the ISPS Code?
Your Answer: (Not answered)
Correct Answer: C (Three months)
💡 ISPS Code Part A/13 and SOLAS XI-2 require ship security drills at intervals of not more than three months, with additional drills where the security level changes.
✗
Question 98. Who is responsible for acting on navigational warnings received during the voyage?
Your Answer: (Not answered)
Correct Answer: B (The master or the officer of the watch)
💡 The master shall ensure warnings received are acted upon and the voyage adjusted if necessary.
✗
Question 99. What must the emergency preparedness procedures contain?
Your Answer: (Not answered)
Correct Answer: A (Identification of the emergencies possible and the alarm and response procedures, duties and external contacts)
💡 The ISM Code requires the emergency preparedness procedures to cover the identification of the emergencies possible, such as fire, flooding, collision, pollution and injury, the alarm and response steps, the duties of each position and shore support and external contacts with search and rescue, the port and the company, with regular drills.
✗
Question 100. What is the purpose of the reference documents in a ship security plan, such as the security assessment report?
Your Answer: (Not answered)
Correct Answer: C (To provide the basis for the measures in the plan, showing the risks they address)
💡 The ISPS Code requires the ship security plan to contain reference documents such as the security assessment report, showing the risks that the measures in the plan address and the conclusions of the assessment, so that the measures are targeted. Without that basis the measures become a formality.