Question 1. In which circumstances must the supply of inert gas to cargo tanks be stopped?
Your Answer: (Not answered)
Correct Answer: A (When the oxygen content of the gas exceeds the prescribed limit or the system fails)
💡 Where the oxygen content of the inert gas exceeds the limit or the system develops a fault, supply must be stopped and contingency measures taken. Otherwise gas with too much oxygen enters the tanks and defeats the inerting.
✗
Question 2. What are the limitations on the use of the automatic pilot?
Your Answer: (Not answered)
Correct Answer: B (Hand steering must be resumed in restricted visibility, dense traffic, narrow channels or when frequent manoeuvring is required)
💡 STCW and SOLAS require hand steering to be resumed in restricted visibility, dense traffic, narrow channels or when frequent manoeuvring is needed on ships using an automatic pilot. The autopilot does not reduce the number of look-outs required and the officer must be ready to steer by hand at any time.
✗
Question 3. What does SOLAS address regarding the stowage of extinguishers?
Your Answer: (Not answered)
Correct Answer: C (Readily accessible and clearly visible positions, marked with the class of fire for which they are suitable)
💡 SOLAS requires extinguishers to be stowed in readily accessible and clearly visible positions, marked with the class of fire for which they are intended. Locking them away or storing them centrally delays the attack on a fire in its early stage.
✗
Question 4. What is the principal method of structural fire protection in accommodation and service spaces under SOLAS II-2?
Your Answer: (Not answered)
Correct Answer: B (Division into main vertical zones by class A and B divisions to limit fire spread)
💡 SOLAS II-2 protects accommodation and service spaces principally by fire-resisting divisions into main vertical zones with class A and B boundaries, rather than by extinguishing or detection equipment alone.
✗
Question 5. What do SOLAS and good practice address regarding monitoring of cargo during a voyage?
Your Answer: (Not answered)
Correct Answer: B (Check cargo securing, temperature and humidity and ventilation as planned, detecting and dealing with abnormalities in good time)
💡 During the voyage, the security of the cargo lashings, the temperature and humidity and the ventilation of the holds and any smell or sign of heating should be checked as planned, with action taken on self-heating, shifting or chemical reaction. A check before sailing alone does not cover the voyage.
✗
Question 6. Why must fire nozzles be of the water-fog and jet dual-purpose type?
Your Answer: (Not answered)
Correct Answer: B (spray suiting oil and electrical fires and covering the approach, the jet reaching a distance and cooling the plating)
💡 One nozzle has to serve fires of quite different kinds. On a surface of burning oil, spray covers the fire, holds off the radiation and cools the compartment, whereas a solid jet breaks the oil about and spreads the fire with it; on electrical equipment and in live spaces spray is what may be used, and then only from the distance the practice allows. A water curtain also covers the party as they close on the seat of the fire. Yet to strike from a distance, or to cool a bulkhead or a cargo surface, a solid column is wanted, which is why the nozzle changes between the two without being swapped. Sparing fresh water and ease of carrying are not the point, and calling the jet a spare misreads what the fire demands.
✗
Question 7. Which channel is used for VHF DSC distress alerting?
Your Answer: (Not answered)
Correct Answer: B (Channel 70)
💡 VHF DSC distress and calling use channel 70, which is not used for speech. Channel 16 is for radiotelephony distress and safety traffic.
✗
Question 8. What is the purpose of the weak link in a liferaft arrangement?
Your Answer: (Not answered)
Correct Answer: D (To part once the raft has inflated and floats, freeing it from the sinking ship)
💡 The weak link has a designed breaking strength so that it parts once the raft has inflated and is lifted by the water, freeing it from the sinking ship. If too strong the raft may be dragged under; if too weak it may part before inflation.
✗
Question 9. What additional safety measure does SOLAS require for remote closing of watertight doors from the bridge?
Your Answer: (Not answered)
Correct Answer: C (An audible and visual alarm before closing, so that persons can move clear)
💡 SOLAS requires an audible and visual alarm and a delay before remote closing of a watertight door from the bridge, giving persons nearby time to move clear and preventing injury. Visual confirmation is not sufficient when operating at a distance.
✗
Question 10. What ventilation is required in spaces carrying dangerous goods?
Your Answer: (Not answered)
Correct Answer: A (Effective ventilation which can be shut off when necessary, removing harmful gas while allowing the air supply to be cut in a fire)
💡 SOLAS requires spaces carrying dangerous goods to have effective ventilation to remove harmful or flammable gas, with openings capable of being closed to cut off the air supply in a fire. The capacity and method of control must suit the cargo carried.
✗
Question 11. What does SOLAS require of an embarkation ladder?
Your Answer: (Not answered)
Correct Answer: A (It must extend from the deck to a point below the lightest waterline as prescribed, enabling persons to board the craft)
💡 SOLAS requires an embarkation ladder to extend from the stowage position or deck to a point below the lightest seagoing waterline, normally not less than 2 m, enabling persons to board the craft safely. Insufficient length forces people to jump.
✗
Question 12. How many firefighter's outfits must a cargo ship of 1000 GT and above carry?
Your Answer: (Not answered)
Correct Answer: C (At least two)
💡 SOLAS II-2/10.10 requires at least two firefighter's outfits on cargo ships of 1000 GT and above. Tankers are additionally required to carry extra outfits, normally four.
✗
Question 13. What does SOLAS address regarding the effect on stability of loading high density cargo?
Your Answer: (Not answered)
Correct Answer: C (A low centre of gravity increases the initial metacentric height but may cause violent rolling and increased structural stress)
💡 High density cargo stowed low produces an excessive initial metacentric height and a stiff ship with a short rolling period and violent rolling, which may shift cargo and increase structural stresses. Stability should therefore be kept within a reasonable range.
✗
Question 14. How must a ship fulfil the duty to render assistance at sea under SOLAS V?
Your Answer: (Not answered)
Correct Answer: A (To proceed with all speed to render assistance where there is reasonable ground to believe another ship is in distress, and to inform the owner or agent)
💡 SOLAS requires the master to proceed with all speed to render assistance where there is reasonable ground to believe a ship is in distress, and to inform the owner or agent. Assistance is a legal duty.
✗
Question 15. What preparation do SOLAS and good seamanship require before berthing or unberthing?
Your Answer: (Not answered)
Correct Answer: A (Test the main engine, steering gear and windlass, check the telegraph and communications, and station the mooring party with duties confirmed)
💡 Before berthing, the main engine, steering gear, windlass and thrusters should be tested, the telegraph and communications checked, and the mooring party stationed with duties confirmed. Failure of any item at the critical moment causes collision or damage.
✗
Question 16. Which statement about cooperation with a marine casualty investigation is correct?
Your Answer: (Not answered)
Correct Answer: C (Provide information truthfully, preserve the scene and evidence and cooperate, without falsifying or concealing)
💡 In a marine casualty investigation the ship should provide information truthfully, preserve the scene and evidence such as VDR data, the official log book, bell and engine movement records and pollution samples, and cooperate. Falsifying, concealing or destroying evidence is a serious violation with legal consequences.
✗
Question 17. What is required when testing DSC or radio equipment in port?
Your Answer: (Not answered)
Correct Answer: A (Test on the prescribed channel or under the prescribed conditions, avoiding a false distress alert and taking precautions before testing)
💡 Testing radio equipment, especially DSC, should be carried out on the prescribed channel or under the prescribed conditions with precautions against transmitting a false distress alert, such as using the specific test setting and avoiding an actual distress alert. A false alert wastes search and rescue resources and may attract a penalty.
✗
Question 18. For the discharge of bilge water treated by an oily water separator, what is the general oil content limit?
Your Answer: (Not answered)
Correct Answer: B (15 parts per million)
💡 Under MARPOL Annex I, bilge water treated by an oily water separator may generally be discharged only if its oil content does not exceed fifteen parts per million, with the 15ppm alarm and automatic stopping device. Tankers are subject to stricter distance and monitoring requirements.
✗
Question 19. What is examined in testing a fixed fire detection and alarm system?
Your Answer: (Not answered)
Correct Answer: B (The alarm function of detectors tested point by point or by section, and that the display corresponds to the actual location)
💡 Testing a fixed detection and alarm system involves triggering detectors point by point or by section and confirming that the alarm sounds correctly and accurately indicates the space concerned, so that the watchkeeper can locate it quickly. Powering it on or listening for the sound alone does not confirm correct sectional indication.
✗
Question 20. What is required when using AIS safety related messages?
Your Answer: (Not answered)
Correct Answer: C (AIS safety related messages may inform other vessels of the ship's status but must not replace the prescribed distress alerting means)
💡 AIS safety related messages, such as not under command, restricted in ability to manoeuvre or in distress, may be used to inform surrounding vessels, but they must not replace the prescribed means of distress alerting, DSC, radiotelephony, satellite or EPIRB. AIS is supplementary only.
✗
Question 21. What does SOLAS address regarding fire protection of the cargo pump room on a tanker?
Your Answer: (Not answered)
Correct Answer: D (Class A divisions at its boundaries with a fixed extinguishing system and fire detection inside)
💡 SOLAS requires the boundaries of a cargo pump room on a tanker to be class A divisions, with a fixed extinguishing system, normally CO2 or foam, and fire detection inside, since the pump room is a high risk space for accumulation and explosion of vapour.
✗
Question 22. A fire drill must do more than muster and call names. What else has to happen?
Your Answer: (Not answered)
Correct Answer: D (mustering to the station bill and reporting, doors, dampers, outfits and communication examined, a fire simulated and water streamed)
💡 The drill has to be worked through for real: mustering to the station bill and reporting the numbers and the positions taken; fire doors and dampers closed and their closing confirmed; the firemen's outfits ready to be put on, the cylinders charged, the communication gear tested; a fire simulated, the way found and approached, the fire pump started and water streamed from a hydrant, so that pump, pipe, nozzle and people are proved together. A fire party drilling alone while the rest wait in their cabins, or a lecture in place of the exercise, tests nothing about the duties the station bill assigns and leaves a record no inspector can accept.
✗
Question 23. What principle should the officer of the watch follow in using ECDIS in confined waters or a port approach?
Your Answer: (Not answered)
Correct Answer: B (Adjust the display scale appropriately and keep the chart updated, avoiding over-reliance on a single display for position)
💡 ECDIS should be used with the scale adjusted to the leg of the passage, charts kept updated and the position cross-checked. Switching off safety alarms or fixing one scale weakens the warning function and increases the risk of grounding.
✗
Question 24. What is the validity of the DOC?
Your Answer: (Not answered)
Correct Answer: C (5 years)
💡 Not more than 5 years, subject to annual verification.
✗
Question 25. How should hazard identification and risk assessment be carried out on board?
Your Answer: (Not answered)
Correct Answer: B (Identify hazards and assess risks for shipboard operations and equipment and take control measures accordingly)
💡 The ISM Code requires hazard identification and risk assessment on board for operations and equipment, covering routine and non-routine work and new equipment and new operations, from which control measures are decided and incorporated into procedures and checklists, bringing risks under control in advance.
✗
Question 26. A 120 m cargo ship has one lifeboat on each side. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (The capacity on each side must accommodate all persons, with at least one boat serving as a rescue boat)
💡 SOLAS requires the capacity on each side of a cargo ship to accommodate all persons on board, with at least one boat meeting the rescue boat requirements. Counting the two boats together would not ensure escape if one side were lost.
✗
Question 27. An alarm was replaced but not entered in the equipment record. What does SOLAS address?
Your Answer: (Not answered)
Correct Answer: A (Changes of equipment must be entered in the record book and kept consistent with the certificate)
💡 SOLAS requires the equipment record, such as the record of equipment for the cargo ship safety equipment certificate, to reflect the equipment fitted and any changes, keeping the certificate, the record and the ship consistent. An unrecorded change breaks that consistency and affects the survey and validity.
✗
Question 28. What should be done with a fire hose after use?
Your Answer: (Not answered)
Correct Answer: A (Clean and dry it, then roll and stow it in the proper manner in place, keeping it ready for use)
💡 After use a fire hose should be washed free of oil and salt water, dried and then rolled and stowed in the proper manner in its position, preventing rot and ageing which affect pressure resistance. Stowing it damp or exposing it long term shortens its life.
✗
Question 29. Where a fixed pressure water-spraying system is fitted in a machinery space, its nozzles shall cover:
Your Answer: (Not answered)
Correct Answer: B (all areas of the machinery space where fire may occur)
💡 SOLAS II-2/10 requires the fixed pressure water-spraying system to cover all areas of the machinery space where fire may occur.
✗
Question 30. What is required for bridge lighting at night?
Your Answer: (Not answered)
Correct Answer: A (Kept dim enough to preserve night vision while providing the lighting needed for instruments and chart work)
💡 Bridge lighting at night should be dim enough to preserve night vision while meeting the need for instrument, chart and equipment lighting, preferably red or dimmable. Excessive or white light destroys the watchkeeper's dark adaptation.
✗
Question 31. What do SOLAS and the related handbooks recommend for contact between survival craft after abandonment?
Your Answer: (Not answered)
Correct Answer: B (Maintain contact by two-way VHF, whistle or light and act together so as to be found more easily)
💡 SOLAS and the survival craft handbooks recommend that craft maintain contact by two-way VHF, whistle or light after abandonment, keeping together or close, acting in a coordinated way and conserving energy and supplies, improving the chance of detection by rescuers.
✗
Question 32. What checks are required after cargo operations on a tanker?
Your Answer: (Not answered)
Correct Answer: A (Confirm valves closed, lines depressurised and drained properly and the deck free of oil before standing down)
💡 After cargo operations on a tanker the procedure requires confirmation that the relevant valves are closed, the lines depressurised and drained, residual oil and drips dealt with, the deck clean and free of oil and the inert gas system normal, with a record made, before standing down, preventing danger from residual vapour.
✗
Question 33. What does a SIRE inspection focus on regarding equipment maintenance?
Your Answer: (Not answered)
Correct Answer: D (Records of execution of the maintenance programme, the condition of critical equipment and records of faults and repairs)
💡 On equipment maintenance a SIRE inspection focuses on whether the planned maintenance programme is actually carried out at the prescribed intervals with records, the real condition of critical equipment such as the main engine, steering gear, fire pumps and emergency source, records of faults and repairs and the identification of equipment and the performance of routine checks.
✗
Question 34. In what state must fire doors be kept at sea under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (Closed, opened only for passage of persons, and fitted with self-closing devices)
💡 SOLAS requires fire doors to be kept closed at sea, opened only when someone passes through, and to be fitted with self-closing devices. Holding them open with rope or wedges is a common PSC deficiency and defeats the fire protection of the division.
✗
Question 35. What radio communication measures are required when operating in polar regions?
Your Answer: (Not answered)
Correct Answer: A (Take account of limited satellite coverage and provide means such as HF unaffected by the region, with enhanced watchkeeping)
💡 Geostationary satellite coverage is limited in polar regions, above about 75 degrees latitude, so SOLAS and the Polar Code require means such as HF communication to be provided with a watch maintained and, where necessary, relaying through a coast station or another ship, ensuring that distress communication gets through.
✗
Question 36. Passenger ships of 4 000 GT and above shall be provided with at least how many independently driven fire pumps?
Your Answer: (Not answered)
Correct Answer: B (3)
💡 SOLAS II-2/10 requires at least three independently driven fire pumps for passenger ships of 4 000 GT and above.
✗
Question 37. How often shall the Company carry out internal audits of the SMS?
Your Answer: (Not answered)
Correct Answer: A (At least once a year)
💡 At least once a year.
✗
Question 38. What are the usual transmit power settings of a ship's VHF radiotelephone?
Your Answer: (Not answered)
Correct Answer: A (1 watt (low) and 25 watts (high))
💡 A ship's VHF normally has two settings, one watt for low power and twenty-five watts for high power, low power being used for short-range communication to reduce interference and high power for long range or distress communication to ensure coverage. Selecting the right setting is a basic watchkeeping requirement.
✗
Question 39. What does SOLAS V require regarding the use of traffic separation schemes?
Your Answer: (Not answered)
Correct Answer: B (Ships must use the scheme in accordance with the relevant rules and navigate within the appropriate lane)
💡 SOLAS V and COLREG require ships to use traffic separation schemes in accordance with the rules, navigating within the appropriate lane in the established direction. Sailing against the flow or crossing at will is not permitted.
✗
Question 40. What is the scope of SOLAS II-1?
Your Answer: (Not answered)
Correct Answer: A (Construction of ships to which the Convention applies, including subdivision, stability and machinery and electrical installations)
💡 SOLAS II-1 covers construction including subdivision, stability and machinery and electrical installations. Fire protection is Chapter II-2 and life-saving appliances Chapter III.
✗
Question 41. What is required to restore survival craft after use?
Your Answer: (Not answered)
Correct Answer: A (Clean promptly after use or a drill, replenish consumables, re-secure and return to stowage, restoring immediate readiness)
💡 SOLAS requires survival craft to be cleaned promptly after a drill or use, the equipment and supplies consumed such as water and pyrotechnics replenished and the craft re-secured and returned to stowage, restoring immediate readiness. Long neglect would make the appliance unusable in an emergency.
✗
Question 42. Safe speed is judged by whether the ship can:
Your Answer: (Not answered)
Correct Answer: A (Stop within a distance appropriate to the circumstances and prevailing conditions)
💡 Stop within a distance appropriate to the prevailing circumstances and conditions.
✗
Question 43. When must the Polar Water Operational Manual be updated?
Your Answer: (Not answered)
Correct Answer: A (On major changes to the ship or its equipment and on updates to the relevant requirements of the Polar Code)
💡 The Polar Code requires the PWOM to be revised on major changes to the ship, its equipment or its operations, and when the relevant requirements are updated, keeping it consistent with the actual situation. Operating from an out-of-date manual creates risk.
✗
Question 44. What is required regarding the difference between indicated and actual rudder angle?
Your Answer: (Not answered)
Correct Answer: D (The difference must be within the permitted tolerance and corrected if exceeded)
💡 SOLAS and good seamanship require the difference between the indicated and actual rudder angle to be within the permitted tolerance. An excessive difference, such as more than five degrees, misleads the helmsman and the officer, and should be found and corrected at trials.
✗
Question 45. Lifeboat and liferaft launching appliances shall be capable of operating when the ship is trimmed by:
Your Answer: (Not answered)
Correct Answer: A (not more than 10°)
💡 SOLAS III/16 requires launching appliances to operate with the ship trimmed up to 10° and listed up to 20°.
✗
Question 46. The Polar Water Operational Manual (PWOM) is intended to:
Your Answer: (Not answered)
Correct Answer: A (provide the ship's operational limitations and procedures for operating in polar waters)
💡 SOLAS XIV/2: the Polar Water Operational Manual provides the ship's operational limitations and procedures for operating in polar waters.
✗
Question 47. What is required regarding the stability information at a renewal survey?
Your Answer: (Not answered)
Correct Answer: D (Verify that it agrees with the actual condition of the ship and update it if the loading conditions have changed)
💡 SOLAS requires the approved stability information to be verified at survey as agreeing with the actual condition of the ship, structure, equipment and loading conditions. Where the ship is converted, the loading method changes or the weight distribution alters, the information should be updated and approved.
✗
Question 48. Why does SOLAS V/19.2.2 require a heading repeater at the steering position?
Your Answer: (Not answered)
Correct Answer: D (So that the helmsman can read the heading without leaving the steering position)
💡 SOLAS requires a heading repeater at the steering position so the helmsman can read the heading directly without leaving his station.
✗
Question 49. A PSC inspection found a lifeboat engine that would not start. What does SOLAS require of lifeboat engines?
Your Answer: (Not answered)
Correct Answer: A (They must start at the prescribed low temperature, with adequate fuel and regular testing including weekly running)
💡 SOLAS requires lifeboat engines to start at the prescribed low temperature, with fuel tanks kept filled, and to be run and tested regularly, including weekly running. No fuel or long neglect of testing are common deficiencies.
✗
Question 50. The securing of cargo units such as containers shall be carried out in accordance with:
Your Answer: (Not answered)
Correct Answer: A (the approved Cargo Securing Manual)
💡 SOLAS VI/5 requires securing of cargo units in accordance with the approved Cargo Securing Manual.
✗
Question 51. What is the total embarkation and launching time for survival craft on a passenger ship?
Your Answer: (Not answered)
Correct Answer: B (Not more than 30 minutes from the abandon ship signal)
💡 Within 30 minutes of the abandon ship signal.
✗
Question 52. A new chief officer needs to familiarise himself with the damage control plan. Where does SOLAS II-1/23 require it to be permanently exhibited?
Your Answer: (Not answered)
Correct Answer: B (On the navigation bridge, in the cargo control room and at the damage control station)
💡 SOLAS II-1/23 requires the damage control plan to be permanently exhibited at the positions where it will be needed, including the navigation bridge, cargo control room and damage control station.
✗
Question 53. What shall the maintenance plan for life-saving appliances include?
Your Answer: (Not answered)
Correct Answer: C (Maintenance intervals and the allocation of responsibility)
💡 Maintenance intervals and the assignment of responsibility.
✗
Question 54. What safety precautions apply when using a CO2 extinguisher?
Your Answer: (Not answered)
Correct Answer: A (Hold the insulated handle to avoid cold burns and leave a poorly ventilated space promptly after use to avoid asphyxiation)
💡 CO2 discharges at a very low temperature, so the insulated handle should be held to avoid cold burns. CO2 displaces oxygen, so after heavy use in a confined space personnel should leave promptly and the space be ventilated, avoiding asphyxiation.
✗
Question 55. If a fire drill cannot be held in a month due to bad weather, what does SOLAS require?
Your Answer: (Not answered)
Correct Answer: A (Hold it as soon as conditions permit and record the reason in the deck log)
💡 SOLAS requires a drill not held in the scheduled month to be held as soon as conditions permit, normally within 24 hours afterwards, with the reason for the delay recorded in the deck log.
✗
Question 56. For a ship loading grain, what should its stability mainly address?
Your Answer: (Not answered)
Correct Answer: D (The heel and stability loss caused by grain shift, with stability calculated as required and measures taken to restrain movement)
💡 Under SOLAS VI/6 and the International Grain Code, when loading grain the assumed heel and stability loss caused by grain shift should be calculated and measures taken such as trimming, longitudinal divisions or strapping to restrain movement, ensuring the required stability criteria are met during the voyage. Grain flows, so it is a focus of stability.
✗
Question 57. In restricted visibility, which measure is NOT in accordance with SOLAS?
Your Answer: (Not answered)
Correct Answer: D (accelerate to pass through quickly)
💡 SOLAS V/8: in restricted visibility measures such as reducing speed, using radar and keeping a proper lookout shall be taken; accelerating is not permitted.
✗
Question 58. What do SOLAS and good practice address regarding insulation resistance of ship's electrical equipment?
Your Answer: (Not answered)
Correct Answer: A (Periodic measurement and recording of insulation resistance, investigating and rectifying any decline)
💡 SOLAS and good practice require periodic measurement and recording of insulation resistance. A fall in insulation resistance usually indicates moisture, ageing or damage, and early detection prevents short circuits and electrical fire.
✗
Question 59. Rescue boat launching appliances shall be capable of launching and recovering the rescue boat when the ship is making headway at up to:
Your Answer: (Not answered)
Correct Answer: A (5 knots)
💡 SOLAS III/16 requires the rescue boat launching appliance to operate at ship's headway of up to 5 knots.
✗
Question 60. What preparations should a ship make before an annual survey?
Your Answer: (Not answered)
Correct Answer: A (Keep equipment in good order and have records, certificates and survey reports ready so that the survey proceeds smoothly)
💡 Before a survey, equipment should be in working order, records and certificates available, routine maintenance completed and known problems dealt with, avoiding deficiencies, or even an effect on the validity of certificates, from equipment not working or records missing.
✗
Question 61. What steering gear checks should be made before navigating in confined waters?
Your Answer: (Not answered)
Correct Answer: C (Check the steering gear alarms, test rudder movement and the rudder angle indicator and confirm the power and control systems are in order)
💡 Before navigating in confined waters such as a narrow channel or when berthing, the steering gear should be tested, the rudder angle indicator checked and the alarms and the power and control systems verified. A sudden steering failure in confined waters has serious consequences.
✗
Question 62. On receiving a distress signal at sea, what shall the master do if the ship is able to assist?
Your Answer: (Not answered)
Correct Answer: A (Proceed with all speed to assist)
💡 SOLAS V/33: the master shall proceed with all speed to assist persons in distress when able to do so.
✗
Question 63. What quantity of fresh water is provided per person in the equipment of a lifeboat?
Your Answer: (Not answered)
Correct Answer: A (Three litres per person)
💡 Under SOLAS III/34 and the equipment requirements for lifeboats, three litres of fresh water should be provided for each person the boat is permitted to accommodate. Fresh water and food are basic provisions for survival after abandonment and a drinking vessel should also be provided.
✗
Question 64. What should be done first when a fire breaks out in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: C (Raise the alarm, organise evacuation and shut off ventilation to the area and, as required, the power)
💡 A fire in accommodation should first trigger the alarm, with evacuation and firefighting organised under the muster list, ventilation shut off as necessary to limit smoke spread and power controlled. Breaking in hastily admits air that feeds the fire and endangers personnel.
✗
Question 65. What is required of the master during a PSC inspection?
Your Answer: (Not answered)
Correct Answer: B (Provide information truthfully and arrange for personnel to assist, without concealing deficiencies or obstructing the inspection)
💡 Port State control is a legal power. The master should provide certificates, records and information truthfully, arrange for the crew to assist and explain the situation truthfully. Concealing, falsifying or obstructing leads to escalation and even coercive measures and a higher risk profile for the ship.
✗
Question 66. For how long must the GMDSS reserve source of energy supply the radio installation when the main source fails under SOLAS IV/9?
Your Answer: (Not answered)
Correct Answer: C (At least one hour, for both passenger and cargo ships)
💡 SOLAS IV/9 requires the reserve source to supply the radio installation for at least one hour. The 18-hour figure applies to emergency lighting on cargo ships under a different regulation.
✗
Question 67. What shall be provided between the bridge and the steering gear compartment?
Your Answer: (Not answered)
Correct Answer: D (Reliable communication such as a sound-powered telephone)
💡 Reliable communication, such as a sound-powered telephone, shall be provided.
✗
Question 68. How does the number of firefighter's outfits differ between tankers and ordinary cargo ships?
Your Answer: (Not answered)
Correct Answer: B (Tankers normally require four outfits, ordinary cargo ships two)
💡 SOLAS II-2/10.10 requires at least two firefighter's outfits on cargo ships of 1000 GT and above. Tankers must carry additional outfits, normally four in total, with extra breathing apparatus.
✗
Question 69. What does SOLAS address regarding action if the inert gas system fails?
Your Answer: (Not answered)
Correct Answer: C (Stop the relevant operations immediately and notify the terminal and take emergency measures)
💡 SOLAS and industry guidance require the relevant operations to stop at once if the inert gas system fails, with the terminal informed and emergency measures taken, preventing explosion from carrying on operations with inerting lost.
✗
Question 70. Which measure complies with SOLAS for protection against electric shock?
Your Answer: (Not answered)
Correct Answer: C (Live parts shall be protected against accidental contact)
💡 Live parts which may be accidentally touched shall be protected.
✗
Question 71. What does SOLAS address regarding protection of hot surfaces in machinery spaces?
Your Answer: (Not answered)
Correct Answer: D (Surfaces above the prescribed temperature must be insulated or guarded, preventing ignition of oil on contact)
💡 SOLAS requires piping and equipment surfaces above the prescribed temperature, such as 220 degrees Celsius, to be insulated or guarded, preventing fuel or lubricating oil from being ignited on contact.
✗
Question 72. What does SOLAS address regarding the minimum height of the double bottom in the machinery space?
Your Answer: (Not answered)
Correct Answer: D (The height must meet the prescribed structural requirements, allowing inspection and maintenance of the inner bottom structure)
💡 SOLAS requires the height of the double bottom to meet the prescribed structural requirements, not less than a specified value, one purpose being to provide space for personnel to inspect and maintain the inner bottom structure and piping and to prevent corrosion from going unnoticed.
✗
Question 73. What readiness of firefighting equipment is required during cargo operations on a tanker?
Your Answer: (Not answered)
Correct Answer: B (Deck foam, hydrants and extinguishers immediately available, with hoses laid out on deck)
💡 SOLAS and industry guidance require a tanker's deck foam system, fire main and extinguishers to be kept immediately available during cargo operations, with fire hoses, couplings and nozzles laid out on deck ready for use, so that a fire can be attacked at once.
✗
Question 74. What does SOLAS address regarding automatic operation of emergency lighting after loss of the main source?
Your Answer: (Not answered)
Correct Answer: A (Emergency lighting must come on automatically after failure of the main source, without manual action)
💡 SOLAS requires emergency lighting to operate automatically when the main source fails, so that the crew has illuminated guidance at the moment of the blackout. A system requiring manual change-over would be delayed by confusion during the blackout, a common deficiency.
✗
Question 75. What is the core principle SOLAS requires for the arrangement of ballast and bilge piping?
Your Answer: (Not answered)
Correct Answer: B (Bilge water from one compartment must not be able to pass through the piping system into another compartment)
💡 SOLAS requires bilge and ballast piping to be arranged so that water cannot pass from one compartment to another through the system, causing inadvertent flooding or cargo contamination. The arrangement is subject to approval.
✗
Question 76. When ECDIS is used to satisfy the carriage of charts requirement, the ship must also have:
Your Answer: (Not answered)
Correct Answer: A (Appropriate back-up arrangements)
💡 SOLAS V/19: ECDIS may satisfy chart carriage only if appropriate back-up arrangements are provided.
✗
Question 77. Where are firefighter's outfits stowed?
Your Answer: (Not answered)
Correct Answer: B (distributed over two or more readily accessible spots, clearly marked and lit, one still reachable if another is cut off)
💡 One question decides the stowage: can they still be reached when a fire is burning. The positions are to be readily accessible, plainly marked and permanently lighted, and distributed according to the size and layout of the ship so that a fire or a space full of smoke does not put every outfit out of reach. How many outfits, with the breathing sets and spares that go with them, is separately laid down; apart does not mean scattered, and each location must serve on its own. To lock them in a store and fetch the key when the alarm goes, to group them where the watchkeeper sits, to keep them with the paperwork because that is easy to register, all push the moment of use later, and a fire does not wait. The periodic check covers the positions as well: goods stacked in front of them, a dead light, a fallen sign, each makes sound gear unreachable.
✗
Question 78. What should a training record contain?
Your Answer: (Not answered)
Correct Answer: A (The date, content, method, participants and the assessment or evaluation of the outcome)
💡 A training record should contain the date, the content such as equipment operation, emergency procedures or safety requirements, the method, the participants and the assessment or evaluation of the outcome, so that the record shows the training was genuinely effective, not merely a sheet of signatures.
✗
Question 79. What is the role of the bulkhead deck in subdivision?
Your Answer: (Not answered)
Correct Answer: A (It is the deck to which the main watertight bulkheads extend upward from the bottom)
💡 The bulkhead deck is the uppermost deck to which the main watertight bulkheads extend, forming the basis for subdivision and damage stability calculations.
✗
Question 80. A cargo ship has lifeboats on one side and liferafts on the other. What is the basic requirement of SOLAS?
Your Answer: (Not answered)
Correct Answer: A (The survival craft capacity on each side must accommodate all persons on board)
💡 SOLAS requires that, whether lifeboats or liferafts are used, the capacity on each side accommodates all persons on board, so everyone can escape if one side is unavailable.
✗
Question 81. What is the main characteristic of a "bulk carrier" as defined in SOLAS XII/1?
Your Answer: (Not answered)
Correct Answer: D (A ship generally having a single deck, top side tanks and hopper side tanks, intended primarily to carry dry cargo in bulk)
💡 SOLAS XII/1 defines a bulk carrier as a ship generally with a single deck, top side tanks and hopper side tanks, intended primarily to carry dry cargo in bulk. Not every ship carrying bulk cargo falls within the definition.
✗
Question 82. What is the purpose of AIS?
Your Answer: (Not answered)
Correct Answer: B (Automatic broadcast and reception of ship identification and navigational information)
💡 To broadcast and receive ship identification and navigational information automatically.
✗
Question 83. What communication is required when entering an enclosed space?
Your Answer: (Not answered)
Correct Answer: B (Continuous communication with the standby person, including periodic contact, with immediate withdrawal if it is lost)
💡 SOLAS and the IMO resolutions require the entrant to maintain continuous communication with the standby person at the entrance, normally by agreed periodic contact, and to withdraw at once if communication cannot be restored, preventing an incident from going unnoticed.
✗
Question 84. Which Code governs the construction of ships carrying liquefied gases in bulk?
Your Answer: (Not answered)
Correct Answer: B (The IGC Code)
💡 The IGC Code.
✗
Question 85. What distinguishes A-0 from A-60 among class A divisions?
Your Answer: (Not answered)
Correct Answer: D (A-60 requires limitation of temperature rise for 60 minutes, while A-0 requires no such limitation but must still prevent smoke and flame)
💡 Class A divisions are graded A-60, A-30, A-15 and A-0 by the period for which temperature rise is limited. A-0 must still prevent the passage of smoke and flame and maintain structural integrity; only the temperature limitation is absent.
✗
Question 86. What must be done on receiving maritime safety information at sea?
Your Answer: (Not answered)
Correct Answer: B (Assess its effect on the voyage promptly, adjusting course or speed and informing those concerned as necessary)
💡 On receiving navigational warnings or weather warnings, the officer of the watch should promptly assess their effect on the route, speed and operations, adjusting the plan and informing the master and others as necessary. Recording alone is not sufficient.
✗
Question 87. What must the navigational safety measures for polar waters include?
Your Answer: (Not answered)
Correct Answer: D (A voyage plan taking account of ice conditions, visibility and the ship's capabilities, with action to be taken if they are exceeded)
💡 The Polar Code requires the voyage plan for polar waters to consider ice conditions, visibility, the ship's ice class capability and the experience of the crew, and to state the action to be taken if conditions exceed the ship's capabilities, such as altering course or stopping.
✗
Question 88. What is the core issue addressed by the International Grain Code in relation to stability?
Your Answer: (Not answered)
Correct Answer: D (The effect on stability of heeling moments arising from grain shifting and settling during the voyage)
💡 The International Grain Code requires the heeling moments from grain shifting and settling to be calculated and the residual stability verified for the prescribed angles of heel, preventing excessive list from grain shift.
✗
Question 89. How many fire pumps are required on a passenger ship of 4000 GT and above?
Your Answer: (Not answered)
Correct Answer: D (Three)
💡 At least three.
✗
Question 90. What is the purpose of self-closing doors on escape routes?
Your Answer: (Not answered)
Correct Answer: B (To block the spread of smoke and flame)
💡 They block smoke and flame from spreading.
✗
Question 91. When is a Declaration of Security concluded?
Your Answer: (Not answered)
Correct Answer: D (When security levels differ between ship and port facility, or the interface risk is high)
💡 ISPS Code A/5: a DoS is concluded when levels differ or the security risk at the interface is high.
✗
Question 92. What do SOLAS and good practice address for periods when the machinery space is unattended?
Your Answer: (Not answered)
Correct Answer: B (Alarms must reliably reach the duty engineer and the bridge, with periodic rounds maintained)
💡 During unattended periods the alarm system must work reliably and transmit alarms to the engineers' accommodation or the bridge, with periodic rounds maintained so that machinery abnormalities are detected promptly. A failed alarm system is a serious deficiency.
✗
Question 93. What compass equipment must a lifeboat carry under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (A compass with suitable mounting in each lifeboat)
💡 SOLAS requires each lifeboat to carry a compass with a suitable mounting, so that a course can be held after abandonment. Its absence or poor mounting reduces the chance of being found.
✗
Question 94. Communication between the engine room and bridge fails at sea so that telegraph orders cannot be confirmed. What does SOLAS II-1 require regarding control of the main machinery?
Your Answer: (Not answered)
Correct Answer: D (The main machinery must be controllable from the bridge, with an independent control position in the machinery space)
💡 SOLAS II-1 requires the main machinery to be operable from the navigation bridge while an independent control position is retained in the machinery space, so the machinery can still be controlled if bridge control fails.
✗
Question 95. Which of the following are common types of fixed fire detection systems?
Your Answer: (Not answered)
Correct Answer: A (Smoke, heat and flame (radiation) detectors)
💡 SOLAS recognises fixed detection systems including smoke, heat and flame (radiation) types, selected according to the nature of the space and the fire characteristics expected.
✗
Question 96. What time limits apply to work in an enclosed space?
Your Answer: (Not answered)
Correct Answer: D (Work according to the conditions and period in the permit, with re-testing and a new permit if the period expires or conditions change)
💡 SOLAS and the IMO resolutions require work in an enclosed space to be carried out under the conditions and for the period stated in the permit, with ventilation and testing maintained. If the permit period expires, ventilation is interrupted or conditions change, work must stop, the atmosphere be re-tested and a new permit issued.
✗
Question 97. Life-saving appliances are kept on a planned maintenance schedule. How are the weekly and monthly checks divided?
Your Answer: (Not answered)
Correct Answer: C (weekly testing of the general alarm and of lighting at muster and embarkation stations, monthly examination of all appliances with their equipment confirmed complete and recorded)
💡 The Convention separates the two by object: weekly, the general emergency alarm system and the emergency lighting at muster and embarkation stations are tested; monthly, all life-saving appliances are examined, boats, rafts, their equipment, launching arrangements and engines being confirmed ready for immediate use, with defects logged. Shrinking the monthly check to one pass before the annual survey, or leaving rafts out of the ship's duties, is how equipment turns up missing when it is wanted.
✗
Question 98. The steering gear suddenly loses power while running. What alarm does SOLAS II-1/29 require?
Your Answer: (Not answered)
Correct Answer: D (An audible and visual alarm on the bridge on failure of the steering gear power unit)
💡 SOLAS II-1/29 requires an audible and visual alarm on the bridge when a steering gear power unit fails, so that the officer can immediately take emergency steering action.
✗
Question 99. An 80 m cargo ship is under plan approval. What does SOLAS II-1/10 require regarding the double bottom?
Your Answer: (Not answered)
Correct Answer: A (For ships of 76 m and above a double bottom shall be fitted as far as practicable between the collision and afterpeak bulkheads)
💡 SOLAS II-1/10 requires a double bottom, as far as practicable, between the collision bulkhead and the afterpeak bulkhead for cargo ships of 76 m and above. It does not require it throughout the whole ship.
✗
Question 100. The purpose of an inclining experiment is to:
Your Answer: (Not answered)
Correct Answer: B (determine the ship's stability elements such as the position of the centre of gravity)
💡 SOLAS II-1/5 requires an inclining experiment to determine stability elements for the master's stability information.