Question 18. Where must emergency lighting be provided, and what is it for?
Your Answer:
(Not answered)
Correct Answer:
C (escape routes and exits, muster and boarding stations and the places where work must go on, lighting that survives the failure)
💡 When the main supply has gone people evacuate through smoke and steam, and a route or an exit that is only painted is no use at all. Emergency lighting therefore covers the escape ways in the machinery and accommodation spaces, the exits, the muster and boarding stations, and the positions where work or watching must still go on, such as the steering gear, the fire pumps and the emergency source itself; spaces where passengers gather carry their own requirement. The lamps come on of themselves when the main supply fails and run from the emergency source for the period laid down, longer for passenger ships than for cargo. Luminous markers only assist, a hand lamp is not a substitute for fixed lighting, and neither takes the place of exit and stairway lit all the way out.