Question 1. What does SOLAS address regarding the effect on stability of loading high density cargo?
Your Answer: (Not answered)
Correct Answer: C (A low centre of gravity increases the initial metacentric height but may cause violent rolling and increased structural stress)
💡 High density cargo stowed low produces an excessive initial metacentric height and a stiff ship with a short rolling period and violent rolling, which may shift cargo and increase structural stresses. Stability should therefore be kept within a reasonable range.
✗
Question 2. What are the security measures at security level 1?
Your Answer: (Not answered)
Correct Answer: B (The minimum protective measures maintained at all times in normal conditions, such as controlling access and monitoring restricted areas)
💡 ISPS Code Part A/12 requires security level 1 to be maintained continuously, including control of access to the ship, monitoring of restricted areas and supervision of persons and cargo embarking. These are the basic measures in normal operation.
✗
Question 3. What safety management is required for modifications to equipment?
Your Answer: (Not answered)
Correct Answer: A (Assess the risk and compliance, obtain the necessary approval, revise documentation and train the crew before the modification)
💡 Before modifying the ship's equipment or structure a risk and compliance assessment should be carried out, considering any effect on certificates and statutory requirements, approval obtained from the classification society or Administration where statutory matters are involved, the documentation and procedures revised and the crew trained, preventing non-compliance or incorrect operation afterwards.
✗
Question 4. What is required for cleaning the galley range hood and exhaust duct?
Your Answer: (Not answered)
Correct Answer: B (Periodic cleaning of grease deposits, preventing accumulated oil from being ignited by heat)
💡 Grease accumulating in a galley hood and exhaust duct is readily ignited by high temperature or flame, so thorough periodic cleaning is required, with the nozzles of the fixed extinguishing system checked for grease blockage. This is a common cause of galley fires.
✗
Question 5. The muster list is found not updated after crew changes and some duties are vacant. The finding is?
Your Answer: (Not answered)
Correct Answer: A (The muster list must match the crew on board; failure to update is an emergency preparedness deficiency)
💡 The muster list should set out the duties and muster station of each crew member in an emergency and be updated promptly with crew changes so that everyone knows their duty. Failure to update leaves some posts vacant and causes confusion in an emergency. It is a deficiency to be corrected.
✗
Question 6. What is the master's obligation regarding charts and nautical publications before sailing?
Your Answer: (Not answered)
Correct Answer: B (They shall be adequate and kept up to date)
💡 SOLAS V/27: charts and nautical publications shall be adequate and kept up to date.
✗
Question 7. A distress signal from another ship is received while at sea. What must the master do?
Your Answer: (Not answered)
Correct Answer: B (Proceed with all speed to render assistance and report the situation to the rescue coordination centre)
💡 SOLAS requires the master to proceed with all speed to the assistance of persons in distress and to inform the search and rescue service. The obligation is released only in the circumstances prescribed, for example when other ships have been instructed to assist.
✗
Question 8. What must the navigational safety measures for polar waters include?
Your Answer: (Not answered)
Correct Answer: D (A voyage plan taking account of ice conditions, visibility and the ship's capabilities, with action to be taken if they are exceeded)
💡 The Polar Code requires the voyage plan for polar waters to consider ice conditions, visibility, the ship's ice class capability and the experience of the crew, and to state the action to be taken if conditions exceed the ship's capabilities, such as altering course or stopping.
✗
Question 9. For how long shall the emergency source of power on a passenger ship be capable of supplying the emergency services?
Your Answer: (Not answered)
Correct Answer: B (36 hours)
💡 SOLAS II-1/42: 36 hours on passenger ships; 18 hours on cargo ships.
✗
Question 10. What does SOLAS address regarding fire protection of the cargo pump room on a tanker?
Your Answer: (Not answered)
Correct Answer: D (Class A divisions at its boundaries with a fixed extinguishing system and fire detection inside)
💡 SOLAS requires the boundaries of a cargo pump room on a tanker to be class A divisions, with a fixed extinguishing system, normally CO2 or foam, and fire detection inside, since the pump room is a high risk space for accumulation and explosion of vapour.
✗
Question 11. A VHF radio installation shall maintain a continuous watch on:
Your Answer: (Not answered)
Correct Answer: A (channel 16)
💡 SOLAS IV/7: a VHF installation shall maintain a continuous watch on channel 16 and, where required, on channel 70.
✗
Question 12. Surveys shall be carried out by:
Your Answer: (Not answered)
Correct Answer: D (officers of the Administration or recognised organisations acting on its behalf)
💡 SOLAS I/5 requires surveys by officers of the Administration or recognised organisations on its behalf.
✗
Question 13. What are the limitations on the use of the automatic pilot?
Your Answer: (Not answered)
Correct Answer: B (Hand steering must be resumed in restricted visibility, dense traffic, narrow channels or when frequent manoeuvring is required)
💡 STCW and SOLAS require hand steering to be resumed in restricted visibility, dense traffic, narrow channels or when frequent manoeuvring is needed on ships using an automatic pilot. The autopilot does not reduce the number of look-outs required and the officer must be ready to steer by hand at any time.
✗
Question 14. What does SOLAS require regarding consistency between the muster list and the persons actually on board?
Your Answer: (Not answered)
Correct Answer: A (The muster list must match the persons actually on board and be updated and re-posted after crew changes)
💡 SOLAS requires the muster list to agree with the persons actually on board and to be updated and re-posted after changes, so that every crew member can find his duty. Using an out-of-date list leaves duties unclear in an emergency.
✗
Question 15. What reward mechanisms for crew suggestions may be used?
Your Answer: (Not answered)
Correct Answer: D (Rewards and recognition may encourage the crew to propose improvements, driving continual refinement)
💡 The ISM system encourages mechanisms of reward, recognition and inclusion in appraisal for crew who put forward effective improvements or detect significant hazards in time, giving them an incentive to take part in safety management and driving continual enhancement and genuine effectiveness of the system.
✗
Question 16. What records and reporting are required for injury and illness?
Your Answer: (Not answered)
Correct Answer: B (Record the time, symptoms, treatment given and outcome and report to the company as required, including for work injuries)
💡 An injury or illness on board should be recorded with the time, how it happened, the symptoms, the first aid and treatment given, the outcome and the follow-up, and reported to the company as the system and regulations require, promptly for a work related injury, occupational disease or serious illness, providing a basis for claims and improvement.
✗
Question 17. What should be done if a launching appliance fails during a drill?
Your Answer: (Not answered)
Correct Answer: B (Stop the operation at once, establish the cause and arrange repair, recording the defect and assessing availability)
💡 If a launching appliance fails during a drill, such as a slipping brake, seized release gear or an abnormal fall, the operation should stop at once, the cause established and repair arranged, with the defect recorded and the availability of the craft assessed. Measures should be taken to maintain the life-saving capability and the company informed.
✗
Question 18. When a pilot is on board, how is responsibility allocated?
Your Answer: (Not answered)
Correct Answer: A (The pilot provides pilotage and advice but does not relieve the master of responsibility for the safety of the ship)
💡 A pilot on board provides local pilotage and manoeuvring advice but does not relieve the master of responsibility for the safety of the ship. The master and officer of the watch should still monitor the ship's movement and, if the pilot's orders are likely to cause danger, should speak up promptly and take necessary action.
✗
Question 19. Should satellite positioning fail, the vessel relies on which alternative means?
Your Answer: (Not answered)
Correct Answer: A (Compass bearings together with chart observation)
💡 Traditional observation with compasses and charts remains the fall-back means.
✗
Question 20. What does SOLAS address regarding level measurement and alarms for fuel and lubricating oil tanks?
Your Answer: (Not answered)
Correct Answer: B (Level measuring arrangements, with high level alarms where overflow is possible, preventing spillage)
💡 SOLAS requires fuel and lubricating oil tanks to be provided with level measuring arrangements and, where overflow is possible, high level alarms, preventing spillage during bunkering or transfer which would create a fire hazard and pollution.
✗
Question 21. What does SOLAS address regarding updating structural strength information for a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (Updated promptly and approved when the structure or loading limitations change)
💡 SOLAS requires the structural strength and loading limitation information of a bulk carrier to be updated promptly and approved by the classification society or the Administration when the structure, equipment or loading conditions change significantly. The crew must not modify it themselves.
✗
Question 22. To which ship types does the Enhanced Programme of Inspections apply?
Your Answer: (Not answered)
Correct Answer: C (Oil tankers and bulk carriers)
💡 SOLAS XI-1/2 applies the enhanced programme of inspections to oil tankers and bulk carriers, imposing stricter survey requirements on these higher-risk ship types. It does not apply to all ships.
✗
Question 23. Who fixes the minimum safe manning document and how is it used on board?
Your Answer: (Not answered)
Correct Answer: A (settled and issued by the flag administration for the type of ship and the trade)
💡 The figure is the flag's to fix: taking the type of ship, her tonnage and machinery power, the trade she plies and her organisation, with the automation she carries, and following the international guidelines on the subject, the administration settles the least number and the grades needed and sends the document to the ship. She is then manned to it, and those actually on board are not below what it asks; if the two disagree the discrepancy is a deficiency however the work is being done. The port State does not as a rule substitute its own calculation, but where it judges the people on board too few or too untalented for her ordinary and emergency working it may consult the flag. To give the number to the society or to leave it with the company crosses a line: the society surveys hull, machinery and equipment, and what the ship costs to man cannot change the least she needs.
✗
Question 24. What does SOLAS require regarding the arrangement of scuppers, inlets and discharges on a ship's sides?
Your Answer: (Not answered)
Correct Answer: C (They must not lead water into spaces where it would be dangerous, and reliable means of closure must be fitted)
💡 SOLAS II-1 regulates the arrangement and closing appliances of overboard scuppers and inlets so that water cannot enter spaces where it would create a hazard through damage or inadvertent operation.
✗
Question 25. What coordination is required when using tugs in confined waters?
Your Answer: (Not answered)
Correct Answer: C (Agree beforehand on the means of communication, the method of working and the command relationship, maintaining communication throughout)
💡 When tugs assist with berthing or manoeuvring in confined waters, the VHF channel, the position for taking the line, the direction of thrust and the command relationship should be agreed in advance, with communication maintained throughout, preventing a misunderstanding of orders from causing collision or damage.
✗
Question 26. How do hinged and sliding watertight doors differ in use while the ship is at sea?
Your Answer: (Not answered)
Correct Answer: C (the hinged door shut before the ship leaves port and kept shut at sea, while a sliding door permitted to be used may be closed at any moment from the bridge and from either side)
💡 The line is drawn not by which way the door swings or how fast it shuts, but by whether it may be standing open at sea. A hinged door, open, leaves the bulkhead doing nothing, so it is to be shut before the ship parts from the port and kept shut on the voyage. A power slide sits where people must pass, so it is allowed to work at sea where permission covers it, on the terms that it can be closed at any moment from the bridge and from either side of it, that the closing has a sound and a indication, that lamps show where the door stands, that it is tested at intervals and written up, and that a document on board says which doors may be used at sea and when they must be closed, the master seeing it carried out before sailing. Whether the indication, the alarm and the local control work is a common thing to test in an inspection and in a drill; to treat it as long as somebody keeps an eye on it is the opposite of the requirement.
✗
Question 27. How must the loading instrument of a bulk carrier be used?
Your Answer: (Not answered)
Correct Answer: B (Compute strength and stability for the planned sequence before cargo work and monitor continuously during it)
💡 SOLAS requires the approved loading instrument to be used to compute hull strength and stability at each stage of the planned sequence before cargo work, with continuous monitoring during the operation and updating as it progresses, preventing excessive stress at any stage. Computing only at the end cannot prevent damage during the work.
✗
Question 28. How should the hands-on ability of the crew be assessed?
Your Answer: (Not answered)
Correct Answer: D (Assessed through practical drills on critical equipment, with training strengthened where it is weak)
💡 The ISM Code and STCW require the practical ability of the crew on critical equipment to be assessed through drills, such as donning breathing apparatus, using extinguishers and hoses, preparing to launch a lifeboat, emergency steering and damage control operations, with training strengthened where skill is lacking, so that the ability is genuinely usable.
✗
Question 29. A PSCO tested ventilation closing devices and found some seized. What does SOLAS address?
Your Answer: (Not answered)
Correct Answer: A (Closing devices of machinery space ventilators must close rapidly to cut off ventilation and air supply)
💡 SOLAS II-2 requires machinery space ventilator closing devices to close rapidly and remain effective, cutting off the air supply in a fire. Seized devices or a lack of regular testing are common deficiencies.
✗
Question 30. What structural measure against inadvertent operation does SOLAS address in machinery spaces?
Your Answer: (Not answered)
Correct Answer: B (Clear identification of critical valves and switches to prevent accidents from incorrect operation)
💡 SOLAS and good practice require clear, durable identification of critical valves and switches in machinery spaces, preventing an accident from opening or closing the wrong item in an emergency. Temporary labels or reliance on memory do not comply.
✗
Question 31. A ship trades between 60 degrees north and south within Inmarsat coverage but too far offshore to receive MF coast station DSC. In which sea area is she?
Your Answer: (Not answered)
Correct Answer: B (Sea area A3)
💡 Sea area A3 is the area, excluding A1 and A2, within the coverage of an Inmarsat geostationary satellite, approximately between 70 degrees north and south. A2 requires coverage of at least one MF coast station DSC.
✗
Question 32. Under the SOLAS chapter V requirements for the field of vision from the conning position, which statement about seeing the sea surface ahead of the bow is correct?
Your Answer: (Not answered)
Correct Answer: B (the field should run from dead ahead to 22.5 degrees abaft the beam on each side, the sea surface ahead being visible at not less than twice the ship's length and in any case 500 m)
💡 Regulation V/22 sets checkable figures: an arc from dead ahead to 22.5 degrees abaft the beam on each side, with the sea surface visible from an eye height of 1.5 times the maximum summer draft or 15 m, whichever is greater, at twice the ship's length but not less than 500 m — in both loaded and ballast conditions.
✗
Question 33. What do SOLAS and the ISM Code require after equipment failure at sea?
Your Answer: (Not answered)
Correct Answer: B (Record the failure and the action taken, report to the company and, where required, to the Administration)
💡 SOLAS and the ISM Code require failures affecting safety to be recorded, including the time, nature of the failure, action taken and result, reported to the company as required and, where necessary, to the Administration or port State, as a basis for the operation of the system and later repair.
✗
Question 34. A ship is 135 m in length. What is the minimum number of lifebuoys required?
Your Answer: (Not answered)
Correct Answer: A (18)
💡 SOLAS III/7.1.1: for ships of 120 m and under 180 m the minimum number of lifebuoys is 18.
✗
Question 35. Which statement about the remote starting of fire pumps is correct?
Your Answer: (Not answered)
Correct Answer: C (Fire pumps should be capable of being started remotely from the bridge or fire control station, or readily started locally, for prompt water supply)
💡 Under SOLAS II-2/10 fire pumps should be capable of being started from the bridge or fire control station, or otherwise ensured to start promptly and supply the fire main in a fire. The means of starting should be stated in the operating instructions, with which the crew should be familiar. The emergency fire pump should have an independent source of power and self-priming capability.
✗
Question 36. What loading limitation must be observed when a bulk carrier loads high density cargo?
Your Answer: (Not answered)
Correct Answer: D (Limits on the maximum weight in each hold and on differences between adjacent holds, preventing excessive local stresses)
💡 Concentrated high density cargo overstresses the tank top and double bottom. SOLAS and the IMSBC Code require limits on the maximum weight per hold and on differences between adjacent holds to be observed. Limiting deadweight alone does not protect the structure.
✗
Question 37. One space uses smoke detectors and another heat detectors. What is the main basis for choosing detector type?
Your Answer: (Not answered)
Correct Answer: A (The type and characteristics of fire likely in the space, such as smoke production or rapid temperature rise)
💡 SOLAS requires the detector type to suit the fire expected in the space: smoke detectors where smoke will be produced, heat detectors where rapid temperature rise without much smoke may occur. The wrong choice delays the alarm.
✗
Question 38. Where must the remote controls of quick closing valves be located?
Your Answer: (Not answered)
Correct Answer: C (Outside the machinery space in an accessible position, clearly marked)
💡 SOLAS requires the remote controls of quick closing valves to be located outside the machinery space in a readily accessible and clearly marked position, so fuel can be shut off even if the space is on fire and cannot be entered.
✗
Question 39. Lifeboats of a cargo ship shall be capable of being launched when the ship is listed up to:
Your Answer: (Not answered)
Correct Answer: B (20°)
💡 SOLAS III/16 requires launching appliances to operate with the ship listed up to 20°.
✗
Question 40. What does SOLAS require for change-over of power supplies for radio equipment?
Your Answer: (Not answered)
Correct Answer: A (Change-over between the main and reserve sources must be completed within the prescribed time, keeping communication unbroken)
💡 SOLAS requires radio equipment to be capable of rapid change-over between the main and reserve sources, so that distress and safety communication is not interrupted for a long period by the change. The change-over arrangement should be tested periodically for reliability.
✗
Question 41. What should be done about a failed water ingress detector on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (Repair promptly and, pending repair, increase manual checks such as sounding the bilges, with records kept)
💡 A failed water ingress detector should be repaired as soon as possible and, pending repair, manual checks increased, such as periodic sounding of holds, ballast tanks and bilges, with the failure and the temporary measures recorded. Switching the system off would remove the warning of flooding and is a serious deficiency.
✗
Question 42. What insulation monitoring is required for the electrical system?
Your Answer: (Not answered)
Correct Answer: B (Insulation monitoring means such as a switchboard insulation resistance meter or monitor, detecting a fall promptly)
💡 SOLAS requires means of insulation monitoring, such as an insulation resistance meter on the main switchboard or an insulation monitor, giving continuous or periodic indication of the insulation to earth and an alarm when it falls, so that leakage and faults are found in time.
✗
Question 43. Before a fixed gas fire-extinguishing system is released, what precaution does SOLAS require?
Your Answer: (Not answered)
Correct Answer: A (An alarm shall be given and evacuation of the space ensured, normally with a delay)
💡 SOLAS requires an audible and visual alarm and a delay or interlock before release of a fixed gas system, so that persons can leave the space and casualties are avoided.
✗
Question 44. A PSCO asks you to explain the term 'Administration' as used in SOLAS. What is the correct meaning?
Your Answer: (Not answered)
Correct Answer: B (The Government of the State whose flag the ship is entitled to fly)
💡 SOLAS I/2 defines 'Administration' as the Government of the State whose flag the ship is entitled to fly. A classification society acts only as a recognised organisation authorised by the Administration.
✗
Question 45. What maintenance does the radar antenna and waveguide require?
Your Answer: (Not answered)
Correct Answer: A (Check that the antenna rotates freely, that the waveguide is not damp or damaged and that the antenna is not obstructed)
💡 Radar requires periodic checking that the antenna turning gear is free, that the waveguide and joints are not damp, damaged or waterlogged and that no new structure such as a mast or antenna obstructs the antenna, with performance checks as prescribed, keeping the detection capability of the radar.
✗
Question 46. What do SOLAS and the IBC Code address regarding the operation of the inert gas system?
Your Answer: (Not answered)
Correct Answer: D (It must remain in operation with tank pressure and oxygen content monitored during cargo, ballast and tank cleaning operations)
💡 SOLAS and the IBC Code require the inert gas system to remain in operation during cargo handling, ballasting and tank washing, with the oxygen content and pressure of each tank monitored continuously. If limits are exceeded, operations must stop to avoid the risk of explosion.
✗
Question 47. What does SOLAS require regarding the loading instrument on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (Bulk carriers of 150 m and above must carry an approved loading instrument for calculating strength and stability during cargo work)
💡 SOLAS XII/11 requires bulk carriers of 150 m and above to be fitted with an approved loading instrument for calculating hull stresses and stability during cargo operations. Unapproved software does not satisfy the requirement.
✗
Question 48. To which new bulk carriers does the double side skin requirement apply?
Your Answer: (Not answered)
Correct Answer: C (a new single-side-skin bulk carrier of 150 m and up carrying solid bulk of a density of 1000 kg/m3 and above)
💡 The requirement addresses new single-side-skin bulk carriers of 150 m and over intended to carry solid bulk cargoes of a density of 1000 kg/m3 and above, the inner skin being supported by the double side when cargo is discharged and in the event of damage; it does not apply to every bulk carrier. Chapter XII carries other structural requirements taking 100 m as their threshold, the two lengths covering different things, and running them together is the commonest error; the numbering and scope of the provisions have been revised, so the text carried on board governs, and this item makes no reference to a particular sub-regulation. Both the length and the density must be met, so "any bulk carrier" and "the cargo decides" alike fail.
✗
Question 49. What shall be done if radio equipment fails?
Your Answer: (Not answered)
Correct Answer: D (Repair it as soon as practicable and report as required)
💡 It shall be repaired as soon as practicable and reported as required.
✗
Question 50. A fire breaks out at the deep-fat fryer in the galley. What fixed protection does SOLAS II-2/10.6 require?
Your Answer: (Not answered)
Correct Answer: A (A fixed extinguishing system over the cooking range, supplemented by a fire blanket)
💡 SOLAS II-2/10.6 requires a fixed extinguishing system over the galley cooking range together with a fire blanket. Portable extinguishers do not satisfy the requirement for a fixed system.
✗
Question 51. Which statement about the use of weather routeing is correct?
Your Answer: (Not answered)
Correct Answer: D (The route should be chosen taking account of weather forecasts and the ship's condition, avoiding severe weather and monitoring the passage plan)
💡 Weather routeing should combine professional weather forecasts with the ship's condition, such as stability, cargo and draught, to choose a relatively safe route avoiding typhoons, heavy seas and severe weather, monitoring and adjusting the plan during the voyage. It is an aid, the final navigational decision being the master's responsibility.
✗
Question 52. After a marine casualty such as a collision or grounding with serious loss, what is required of the master as to reporting?
Your Answer: (Not answered)
Correct Answer: C (Report to the flag Administration as required and, where necessary, to the nearest coastal State, and preserve the relevant records and information)
💡 Under SOLAS I/21 and related requirements, after a marine casualty the ship should report to the flag Administration as required and, where necessary, to the nearest coastal State, and should preserve evidence, the official log book and related records for the investigation. Concealing or delaying a report aggravates liability.
✗
Question 53. What does the shipboard oil pollution emergency plan have the crew exercise in?
Your Answer: (Not answered)
Correct Answer: A (the alarm and the report when oil is seen, getting the gear out, working the containment and recovery, and who is to be told and what is said to them)
💡 The plan has to set out each step as the ship would take it: who sees it and when, how the source and position of the spill are judged, the order of raising the alarm and telling the bridge, the muster and the split of duties, what valves and pumps are worked on deck, where the boom and the absorbents live and who handles them, how the spread is held and the oil gathered, and then the report to the company, to the coastal State and to the port, its form and its timing, contact with the salvors and with other ships, the writing up and the look back afterwards. It is the exercise that puts these in the crew's hands: once a man has carried the gear and sent a practice report he knows what his own ship, at her speed and with her arrangement, can actually do. Exercises go best alongside the other drills and at the intervals the plan names, and what they show comes back into the plan and the training. A signature with no exercise, or another drill's record standing in for it, will not hold when the inspection asks or when the oil is on the water.
✗
Question 54. What is the use of the maximum permissible centre of gravity curve in the stability information?
Your Answer: (Not answered)
Correct Answer: D (To judge quickly during loading whether the centre of gravity exceeds the permissible value at each displacement)
💡 The curve or table of maximum permissible height of the centre of gravity gives the permissible value for each displacement, so that during loading the calculated actual height can simply be compared with it to judge whether stability is satisfactory, without computing the full stability curve each time.
✗
Question 55. Which spaces must emergency lighting cover at a minimum under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (Embarkation stations, survival craft stowage positions, escape routes, machinery spaces and the bridge, among other essential spaces)
💡 SOLAS requires emergency lighting for essential spaces including embarkation stations, survival craft stowage positions, escape routes, machinery spaces, the bridge and fire control stations, supporting abandonment and emergency operations.
✗
Question 56. What should be noted about fog signals in restricted visibility?
Your Answer: (Not answered)
Correct Answer: A (Sound fog signals as COLREG prescribes and listen attentively to other vessels' signals to judge bearing and movement)
💡 In restricted visibility fog signals should be sounded as COLREG prescribes, for example one prolonged blast at intervals of not more than two minutes for a power-driven vessel under way, while listening carefully to other vessels' signals to judge their approximate bearing and movement, combined with radar observation. Sounding must not be delayed.
✗
Question 57. What does SOLAS address regarding action if the inert gas system fails?
Your Answer: (Not answered)
Correct Answer: C (Stop the relevant operations immediately and notify the terminal and take emergency measures)
💡 SOLAS and industry guidance require the relevant operations to stop at once if the inert gas system fails, with the terminal informed and emergency measures taken, preventing explosion from carrying on operations with inerting lost.
✗
Question 58. Apart from when navigation requires, in what state should watertight doors be kept?
Your Answer: (Not answered)
Correct Answer: A (Closed, with their status indicated on the navigation bridge)
💡 SOLAS II-1/15 requires watertight doors to be kept closed except when navigation necessitates opening, with their status shown on the bridge. Being left permanently open is a common PSC deficiency.
✗
Question 59. Which measure complies with SOLAS for protection against electric shock?
Your Answer: (Not answered)
Correct Answer: C (Live parts shall be protected against accidental contact)
💡 Live parts which may be accidentally touched shall be protected.
✗
Question 60. The sewage treatment plant is found not in operation and untreated sewage is being discharged directly. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Discharging untreated sewage does not meet the rules, a pollution prevention deficiency)
💡 Discharge of sewage must meet the applicable rules, that is, be treated by an approved treatment plant and meet the discharge conditions, or be discharged as permitted beyond the specified distance. Direct discharge of untreated sewage with the plant not running does not meet pollution prevention requirements and is a deficiency to be corrected.
✗
Question 61. Which statement about the lashing and securing of containers is correct?
Your Answer: (Not answered)
Correct Answer: A (Securing should be carried out in accordance with the approved cargo securing manual, taking account of the effect of the trading area and ship motions on the securing loads)
💡 Under SOLAS V/5 and the Code of Safe Practice for Cargo Stowage and Securing, containers and similar cargo should be lashed and secured in accordance with the approved cargo securing manual, taking account of the trading area, ship motions and accelerations on the securing loads, preventing cargo shifting or going overboard during the voyage.
✗
Question 62. What is the emergency bilge suction for?
Your Answer: (Not answered)
Correct Answer: B (Dewatering the machinery space using the main engine cooling pump)
💡 It allows the machinery space to be dewatered using the main cooling or sea water pump.
✗
Question 63. With regard to spare antennas:
Your Answer: (Not answered)
Correct Answer: C (a spare antenna shall be provided so that it can be rigged if the main antenna is damaged)
💡 SOLAS IV/13 requires a spare antenna capable of being rigged if the main antenna is damaged.
✗
Question 64. How does a non-conformity differ from an accident under the system?
Your Answer: (Not answered)
Correct Answer: D (a non-conformity being a state in which a requirement is not met, an accident an event that has caused injury, loss or pollution, and both, with near misses, to be reported and looked into)
💡 The non-conformity says a requirement has not been met: an entry missing from the record book, a drill or a course not done as planned, a survey overdue, the procedure on paper and another way on board, an observation from the last audit left unclosed. None of these has yet harmed anyone and all of them call for correction. The accident is named by what it did - injury, loss or pollution has in fact happened. Both are to be reported, looked into for cause and corrected, and the inquiry is meant to end at the management system rather than at the statement that a man handled it badly, which is also why the hazardous occurrence is listed by itself: the close run that did no harm is precisely the accident that has not yet happened. Downgrading whatever did no damage to a non-conformity, or holding that a departure in how work is done is not one either, takes the edge off the statistics and leaves the review with nothing to decide on.
✗
Question 65. Where shall the emergency radio communication equipment be located for ready access?
Your Answer: (Not answered)
Correct Answer: B (Wherever it is readily accessible on the ship)
💡 SOLAS IV/9: the equipment shall be sited so that it is readily accessible at all times.
✗
Question 66. When trading outside sea area A1, NAVTEX is one of the principal means of receiving MSI. Which is the international NAVTEX frequency?
Your Answer: (Not answered)
Correct Answer: D (518 kHz)
💡 The international NAVTEX service uses 518 kHz. 490 kHz is the national NAVTEX frequency and 2182 kHz is the MF radiotelephony distress frequency.
✗
Question 67. What protection against freezing is required for bilge and fire piping in cold weather?
Your Answer: (Not answered)
Correct Answer: C (Drain or insulate piping liable to freeze, preventing water in it freezing and bursting the pipe)
💡 In cold weather the bilge, fire and ballast piping liable to freeze should be protected by draining, insulation or trace heating, preventing trapped water from freezing and expanding to burst the pipe or valves and so impairing the supply and drainage capability needed in an emergency.
✗
Question 68. As a minimum, the flash point of fuel oil (excluding diesel lubricating oil) shall be:
Your Answer: (Not answered)
Correct Answer: B (60°C)
💡 SOLAS II-2/4.2: fuel oil, other than diesel lubricating oil, shall have a flash point of at least 60°C.
✗
Question 69. What do SOLAS and good practice address regarding the conduct of ship during drills?
Your Answer: (Not answered)
Correct Answer: D (Sea state and the ship's condition must be considered, avoiding drills in hazardous conditions that could cause an accident)
💡 SOLAS and good practice require the timing and conditions of a drill to be chosen with regard to the sea state, the trading area and the ship's condition, with particular care or postponement in heavy weather or confined waters, avoiding casualties or damage caused by the drill itself.
✗
Question 70. The steering gear takes 35 seconds to move the rudder from 35 degrees one side to 30 degrees the other. What is the finding?
Your Answer: (Not answered)
Correct Answer: B (It exceeds the prescribed 28 seconds and does not comply; the steering gear performance must be investigated)
💡 SOLAS II-1/29 requires the main steering gear, at maximum service speed and deepest seagoing draught, to complete the movement from 35 degrees one side to 30 degrees the other within 28 seconds. Thirty five seconds exceeds the limit and indicates a problem with the power or control capability of the steering gear.
✗
Question 71. An embarkation ladder is found with missing treads and corroded ropes. The finding is?
Your Answer: (Not answered)
Correct Answer: C (The embarkation ladder is vital for safe boarding during abandonment; damage is a serious life-saving deficiency)
💡 The embarkation ladder is the means by which personnel board the survival craft from the deck during abandonment and its treads, side ropes and securing arrangements should be intact. Damage may cause a person to fall and be injured during emergency boarding, directly endangering safety. It is a serious life-saving deficiency to be corrected.
✗
Question 72. What preparation do SOLAS and BMP require before entering a high risk area?
Your Answer: (Not answered)
Correct Answer: C (Complete a security risk assessment, apply hardening and protective measures, conduct drills and report to the company, with reporting maintained)
💡 Before entering a high risk area a security risk assessment should be completed, protective and hardening measures applied in accordance with BMP, drills held, the company informed and reports made to the relevant bodies as required, so that the ship is prepared if threatened.
✗
Question 73. Which best describes the fundamental objective of SOLAS Chapter II-2?
Your Answer: (Not answered)
Correct Answer: C (To minimise fire risk and protect persons and the ship by fire prevention, detection and extinguishing)
💡 SOLAS II-2 combines fire prevention, detection and extinction, using structural protection, detection and alarm systems and fixed extinguishing systems. Extinguishing alone is only part of the objective.
✗
Question 74. With regard to charts, which requirement is correct?
Your Answer: (Not answered)
Correct Answer: A (up-to-date charts covering the intended voyage shall be carried)
💡 SOLAS V/27 requires up-to-date charts covering the intended voyage.
✗
Question 75. The deck water seal in a tanker inert gas system primarily serves to:
Your Answer: (Not answered)
Correct Answer: A (prevent cargo tank gas from flowing back into the machinery space)
💡 SOLAS II-2/5 requires a deck water seal to prevent backflow of cargo tank gas to the inert gas generator and machinery space.
✗
Question 76. What is the purpose of the Polar Water Operational Manual (PWOM)?
Your Answer: (Not answered)
Correct Answer: B (To provide the master and crew with operational procedures and limitations for polar waters)
💡 The Polar Code requires a PWOM setting out procedures, operational capabilities, limitations and emergency arrangements for use by the master and officers when operating in ice.
✗
Question 77. What does SOLAS require regarding manoeuvring information?
Your Answer: (Not answered)
Correct Answer: C (Manoeuvring information such as turning circles and stopping distances must be available on board for the master's use)
💡 SOLAS V/19.2.8 requires manoeuvring information such as turning circles, stopping distances and track reach to be on board for the master's use in narrow channels and during berthing. Shore-side retention does not comply.
✗
Question 78. What are the common risks in launching and recovering survival craft?
Your Answer: (Not answered)
Correct Answer: A (Inadvertent operation of the release gear dropping the boat and injuring persons, and persons being crushed between the falls and the boat)
💡 The principal risks in launching and recovering a lifeboat include the release gear operating inadvertently and dropping the boat, persons being crushed between the falls and the boat and the boat striking the ship's side. Procedures should be strictly followed, coordination maintained and positions chosen with care.
✗
Question 79. What monitoring of moisture content is required for cargoes liable to liquefy?
Your Answer: (Not answered)
Correct Answer: B (Confirm the moisture content is below the transportable moisture limit before loading and guard against rain increasing it during loading)
💡 The IMSBC Code requires confirmation that the moisture content is below the TML before loading, normally from a certificate or test report, with attention during loading to rain, changes in the moisture of the cargo and water in the hold, preventing the content rising above the TML and liquefaction at sea.
✗
Question 80. On the navigation bridge, the main propulsion machinery shall be provided with:
Your Answer: (Not answered)
Correct Answer: A (indications of speed and direction of rotation and the necessary communication)
💡 SOLAS II-1/31 requires indications of propeller speed and direction and necessary communication on the bridge.
✗
Question 81. Emergency lighting shall be capable of operating for at least:
Your Answer: (Not answered)
Correct Answer: B (18 hours)
💡 SOLAS II-1/42 requires the emergency source to provide emergency lighting for at least 18 hours.
✗
Question 82. What are the duties of the deck watch during cargo operations on a tanker?
Your Answer: (Not answered)
Correct Answer: B (Monitor piping, valves and tanks, detecting leaks, overflow or abnormalities and taking action)
💡 During cargo operations on a tanker a deck watch must be maintained, monitoring pipeline joints for leakage, tank levels and pressures, overflow and unusual noise, with communication kept with the engine room and the terminal, so that abnormalities are detected and dealt with promptly.
✗
Question 83. Regarding the master's duties, which is correct?
Your Answer: (Not answered)
Correct Answer: D (the master has ultimate responsibility for safe navigation and shall take charge when necessary)
💡 SOLAS V/34: the master has ultimate responsibility for safe navigation and shall take charge when necessary.
✗
Question 84. A fixed fire detection and fire alarm system shall cover:
Your Answer: (Not answered)
Correct Answer: C (machinery spaces, accommodation spaces and control stations as specified)
💡 SOLAS II-2/7: a fixed fire detection and fire alarm system shall cover machinery spaces, accommodation spaces and control stations as specified.
✗
Question 85. What does SOLAS address regarding sounding and observation arrangements for fuel oil tanks?
Your Answer: (Not answered)
Correct Answer: C (Safe and reliable measuring arrangements, preventing oil from overflowing or spraying out)
💡 SOLAS requires fuel oil tank measuring arrangements to be safe and reliable, such as self-closing sounding pipes or closed level gauges, preventing oil from overflowing or spraying onto hot surfaces during measurement and causing fire.
✗
Question 86. How many means of escape are required on each deck in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: A (At least two, widely separated)
💡 At least two widely separated means of escape per deck.
✗
Question 87. At the change of watch, which statement about what should be handed over is correct?
Your Answer: (Not answered)
Correct Answer: A (Course and speed, position, traffic situation, condition of the ship's equipment and existing risks and other essential information)
💡 The change of watch should ensure that the relieving officer takes responsibility with a full understanding of the situation, including course and speed, position and passage plan, traffic and intentions, equipment condition and alarms, weather and visibility, and existing risks and outstanding matters. A poor handover is a common cause of navigational accidents.
✗
Question 88. Where a certificate expires and the ship is not in a port of survey, the Administration may extend the certificate for a period not exceeding:
Your Answer: (Not answered)
Correct Answer: A (5 months)
💡 SOLAS I/14: where a ship is not in a port of survey at expiry, the Administration may extend the certificate for a period not exceeding 5 months.
✗
Question 89. The whistle is found inoperative or the sound signalling appliance has failed. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Failure of the sound signalling appliance affects collision avoidance and navigation in fog, a deficiency to be corrected)
💡 The whistle and sound signalling appliance are used to give the prescribed signals in fog, in narrow channels and when coordinating with other ships, being important means of collision avoidance and safe navigation. Failure prevents the ship from giving the required sound signals and increases the risk of collision. It is a deficiency to be corrected.
✗
Question 90. What does SOLAS address regarding automatic closing of fire dampers?
Your Answer: (Not answered)
Correct Answer: C (Fire dampers where ducts pass through class A divisions must close automatically or by remote control in a fire)
💡 SOLAS requires fire dampers at duct penetrations of class A divisions to close automatically, for example by fusible elements, or by remote control, preventing fire and smoke from spreading through the ventilation system. Manual closing alone is often too late.
✗
Question 91. What medical care is required on board?
Your Answer: (Not answered)
Correct Answer: A (Prescribed medicines and medical equipment, access to medical guides and personnel trained in first aid)
💡 SOLAS and the MLC require a ship to carry the prescribed medicines and medical equipment, determined by the trading area and the number of crew, to keep the International Medical Guide for Ships and access to medical advice available and to have crew trained in first aid and medical care, so that basic treatment can be given on board.
✗
Question 92. What does the propeller speed and direction indicator show?
Your Answer: (Not answered)
Correct Answer: A (The speed and direction of rotation of the propeller)
💡 The speed and direction of rotation of the propeller.
✗
Question 93. Where shall the collision bulkhead be fitted and why?
Your Answer: (Not answered)
Correct Answer: B (Forward, to confine flooding from bow damage)
💡 The collision bulkhead limits flooding to the forward region after a collision.
✗
Question 94. What is the purpose of the ship security assessment?
Your Answer: (Not answered)
Correct Answer: C (To identify security risks and weaknesses of the ship, forming the basis for the ship security plan)
💡 ISPS Code Part A/6 requires a ship security assessment identifying security risks, weaknesses and possible threats, the results of which form the basis for developing and updating the ship security plan.
✗
Question 95. On a passenger ship, each space shall be provided with at least how many means of escape?
Your Answer: (Not answered)
Correct Answer: D (2)
💡 SOLAS II-2/13 requires at least two widely separated means of escape from each space on a passenger ship.
✗
Question 96. What is required when using AIS safety related messages?
Your Answer: (Not answered)
Correct Answer: C (AIS safety related messages may inform other vessels of the ship's status but must not replace the prescribed distress alerting means)
💡 AIS safety related messages, such as not under command, restricted in ability to manoeuvre or in distress, may be used to inform surrounding vessels, but they must not replace the prescribed means of distress alerting, DSC, radiotelephony, satellite or EPIRB. AIS is supplementary only.
✗
Question 97. What compliance with ship reporting systems is required?
Your Answer: (Not answered)
Correct Answer: A (Report at the prescribed positions and times with the prescribed content and report changes in the ship's condition promptly)
💡 SOLAS V/11 requires ships to report the prescribed content, such as name, position, course and speed, cargo and defects, at the prescribed positions and times, and to report promptly any change affecting the safety of navigation, such as equipment failure or deviation from the route.
✗
Question 98. What is the requirement for the brake of a lifeboat launching appliance?
Your Answer: (Not answered)
Correct Answer: D (It must brake reliably and hold the boat in position during lowering)
💡 SOLAS requires a reliable brake so that the lifeboat can be stopped and held at any position during lowering, preventing an uncontrolled descent.
✗
Question 99. Why must fire nozzles be of the water-fog and jet dual-purpose type?
Your Answer: (Not answered)
Correct Answer: B (spray suiting oil and electrical fires and covering the approach, the jet reaching a distance and cooling the plating)
💡 One nozzle has to serve fires of quite different kinds. On a surface of burning oil, spray covers the fire, holds off the radiation and cools the compartment, whereas a solid jet breaks the oil about and spreads the fire with it; on electrical equipment and in live spaces spray is what may be used, and then only from the distance the practice allows. A water curtain also covers the party as they close on the seat of the fire. Yet to strike from a distance, or to cool a bulkhead or a cargo surface, a solid column is wanted, which is why the nozzle changes between the two without being swapped. Sparing fresh water and ease of carrying are not the point, and calling the jet a spare misreads what the fire demands.
✗
Question 100. Emergency lighting shall ensure illumination of:
Your Answer: (Not answered)
Correct Answer: D (escape routes, muster stations, embarkation stations, steering gear and fire pump spaces)
💡 SOLAS II-1/42 requires emergency lighting to cover escape routes, muster and embarkation stations, fire pump and steering gear spaces.