Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. From what gross tonnage must ships carry AIS?
Your Answer: (Not answered)
Correct Answer: B (300 GT)
💡 SOLAS V/19: AIS is required for ships of 300 GT and above on international voyages.
✗
Question 2. What do SOLAS and the IMDG Code require if dangerous goods leak on board?
Your Answer: (Not answered)
Correct Answer: D (Follow the measures in the EmS Guide for the relevant UN number, preventing ignition and personnel exposure)
💡 SOLAS VII requires the measures in the EmS Guide for the UN number concerned to be followed, including personal protection, ventilation, collection and isolation. Some substances react with water, so washing with water is not always appropriate; the Guide must be followed.
✗
Question 3. What is required in setting the safety contour on ECDIS?
Your Answer: (Not answered)
Correct Answer: D (Set it in accordance with the ship's draught and the required under-keel clearance so that it reflects the actual safe depth)
💡 The safety contour and safety depth on ECDIS should be set according to the ship's draught, her under-keel clearance policy and the depths of the area, so that the system alarms accurately when approaching shoal water. An unsuitable default setting may make the alarm ineffective or cause constant false alarms.
✗
Question 4. Which statement about keeping a lookout is correct?
Your Answer: (Not answered)
Correct Answer: B (A proper lookout should be kept at all times by qualified persons using sight, hearing and all available means)
💡 Under SOLAS V/19 and the collision regulations every vessel should at all times maintain a proper lookout by sight and hearing as well as by all available means appropriate to the circumstances, so as to make a full appraisal of the situation and the risk of collision. Combining the lookout with the conning by one person is a common cause of accidents.
✗
Question 5. What must be checked on board when loading containers under SOLAS and the CSS Code?
Your Answer: (Not answered)
Correct Answer: D (The weight, position and securing of containers, preventing structural damage or securing failure from overweight boxes)
💡 SOLAS VI/2 requires the declared weight of containers to be verified against actual weight and securing carried out in accordance with the securing manual. Overweight boxes or improper securing cause structural damage and loss of cargo overboard.
✗
Question 6. Where a certificate expires and the ship is not in a port of survey, the Administration may extend the certificate for a period not exceeding:
Your Answer: (Not answered)
Correct Answer: A (5 months)
💡 SOLAS I/14: where a ship is not in a port of survey at expiry, the Administration may extend the certificate for a period not exceeding 5 months.
✗
Question 7. What reporting is required for a security incident?
Your Answer: (Not answered)
Correct Answer: A (Report at once under the procedure to the company, the Administration and the relevant parties, recording the circumstances)
💡 A security incident such as unauthorised boarding, the introduction of weapons, theft or sabotage requires immediate reporting under the ship security plan to the company, the Administration where necessary and the port facility security officer, recording the course of the incident, the action taken and the result, with analysis and improvement to follow.
✗
Question 8. What does SOLAS require regarding the loading instrument on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (Bulk carriers of 150 m and above must carry an approved loading instrument for calculating strength and stability during cargo work)
💡 SOLAS XII/11 requires bulk carriers of 150 m and above to be fitted with an approved loading instrument for calculating hull stresses and stability during cargo operations. Unapproved software does not satisfy the requirement.
✗
Question 9. What is the basic principle for selecting portable extinguishers for a machinery space?
Your Answer: (Not answered)
Correct Answer: B (the class of fire likely in the space deciding the choice, oil and electrical fires requiring a suitable agent, the number and siting as prescribed)
💡 In a machinery space the likely fires are oil and electrical. Water will spread a burning oil fire and carries the shock risk on live equipment, so it belongs to solid combustible fires; here foam, powder or carbon dioxide suits the class, with the capacity, number and siting the rules call for along passages and in spaces, placed where a hand can reach it and not blocked by gear or cargo. Carbon dioxide released in quantity in a small closed space drives the oxygen down, which has to be thought of as the party withdraws. Counting only the extinguishers and their service dates, without regard to whether the type suits the space, is a deficiency waiting to be written up and a mistake waiting to be made at the fire itself.
✗
Question 10. Which Code governs the classification of dangerous goods?
Your Answer: (Not answered)
Correct Answer: D (The IMDG Code)
💡 The IMDG Code.
✗
Question 11. Sea area A2 means an area, excluding sea area A1, within the coverage of at least one:
Your Answer: (Not answered)
Correct Answer: C (MF coast station with continuous alerting capability)
💡 SOLAS IV/2: Sea area A2 is the area, excluding A1, within the coverage of at least one MF coast station with continuous DSC alerting.
✗
Question 12. What verification of the effectiveness of rectification is required?
Your Answer: (Not answered)
Correct Answer: B (Verify through re-inspection, testing or practical demonstration, not merely by documents or undertakings)
💡 After rectification its effectiveness should be verified by actual re-inspection, testing equipment or observing the crew, such as re-testing after a repair or checking the crew's operation after training, with evidence that the deficiency has been removed. A plan or an undertaking does not show that the work is done.
✗
Question 13. What does SOLAS address regarding stopping machinery space ventilation fans?
Your Answer: (Not answered)
Correct Answer: D (Fans must be capable of remote stopping, with the control outside the space)
💡 SOLAS requires machinery space ventilation fans to be capable of being stopped remotely, with the control outside the space, working together with the closing of dampers to cut off the air supply quickly in a fire and prevent it from intensifying.
✗
Question 14. When clear grounds are found during a PSC inspection, what is the next step?
Your Answer: (Not answered)
Correct Answer: A (A more detailed inspection, with detention if deficiencies are serious)
💡 PSC procedures require a more detailed inspection where clear grounds exist. Detention follows only where deficiencies are clearly hazardous; PSCOs do not normally fine ships or withdraw certificates directly.
✗
Question 15. What is the time requirement for launching and recovering a rescue boat under SOLAS III?
Your Answer: (Not answered)
Correct Answer: B (Recovery must be possible within 5 minutes in moderate sea conditions)
💡 SOLAS III requires a rescue boat to be capable of being launched and recovered within 5 minutes in moderate sea conditions, so that a person in the water can be recovered quickly.
✗
Question 16. What time requirement does SOLAS address for the stowage of and embarkation into survival craft?
Your Answer: (Not answered)
Correct Answer: D (All persons must be able to embark and the craft launched within the prescribed time)
💡 SOLAS requires stowage and embarkation arrangements enabling all persons to board and the craft to be launched within the prescribed time, based on the rate at which the ship might sink. Excessive time means not everyone could get away.
✗
Question 17. Trading at high latitudes: what more does the radio installation need?
Your Answer: (Not answered)
Correct Answer: B (alerting and watch resting chiefly on high and medium frequencies, the beacon being one that works through polar-orbiting satellites)
💡 Those waters lie outside the view of a geostationary satellite, so distress alerting and the safety traffic fall mainly on digital selective calling in the medium and high frequencies, and maritime safety information comes by narrow-band direct printing on high frequencies, receivers being required to work there. The beacon depends on the polar-orbiting system, so its fit and its stowage are settled with a high-latitude alert in mind. Beyond the gear itself: propagation in those frequencies changes with the hour and with solar activity, an antenna can fail under ice, and the run from the bridge to that antenna matters. The equipment list, the frequencies watched and the back-ups, a usable source of power and a second means of alerting among them, are checked against the radio record and the certificates rather than judged from experience earned further south or north.
✗
Question 18. What is required where ventilation ducts pass through a fire division?
Your Answer: (Not answered)
Correct Answer: C (Fire flaps or equivalent measures should be fitted at the penetration to prevent flame and smoke spreading along the duct)
💡 Under SOLAS II-2/9 where a ventilation duct passes through an A-class or B-class division fire flaps or equivalent measures should be fitted, with means of automatic and manual operation where necessary, to prevent flame and smoke spreading through the duct between spaces. The operability of the flaps should be maintained.
✗
Question 19. The purpose of an inclining experiment is to:
Your Answer: (Not answered)
Correct Answer: B (determine the ship's stability elements such as the position of the centre of gravity)
💡 SOLAS II-1/5 requires an inclining experiment to determine stability elements for the master's stability information.
✗
Question 20. On the navigation bridge, the main propulsion machinery shall be provided with:
Your Answer: (Not answered)
Correct Answer: A (indications of speed and direction of rotation and the necessary communication)
💡 SOLAS II-1/31 requires indications of propeller speed and direction and necessary communication on the bridge.
✗
Question 21. What is the primary fire safety objective of SOLAS Chapter II-2?
Your Answer: (Not answered)
Correct Answer: A (To prevent the occurrence and spread of fire)
💡 The primary objective is to prevent fires and limit their spread.
✗
Question 22. What do SOLAS and good practice address regarding monitoring of cargo during a voyage?
Your Answer: (Not answered)
Correct Answer: B (Check cargo securing, temperature and humidity and ventilation as planned, detecting and dealing with abnormalities in good time)
💡 During the voyage, the security of the cargo lashings, the temperature and humidity and the ventilation of the holds and any smell or sign of heating should be checked as planned, with action taken on self-heating, shifting or chemical reaction. A check before sailing alone does not cover the voyage.
✗
Question 23. What preparation is required before a ship enters polar waters?
Your Answer: (Not answered)
Correct Answer: D (Assess the ice conditions, prepare the procedures in the PWOM, check equipment for low temperature operation and confirm crew training)
💡 The Polar Code requires an assessment of ice conditions and the voyage, preparation of the operational procedures and emergency arrangements in the PWOM, checking the availability of essential equipment at low temperature including fuel, hydraulic oil and batteries, confirmation of appropriate crew training and adequate emergency supplies, before entering polar waters.
✗
Question 24. What does SOLAS address regarding separation between the cargo area and machinery space of a tanker?
Your Answer: (Not answered)
Correct Answer: B (A-60 class separation between the cargo tank area and category A machinery spaces, preventing passage of vapour and fire)
💡 SOLAS requires A-60 class separation between the cargo tank area and category A machinery spaces of a tanker, preventing vapour from entering the machinery space or fire spreading from it into the cargo area with far greater consequences.
✗
Question 25. What rescue arrangement is required when entering an enclosed space?
Your Answer: (Not answered)
Correct Answer: B (A standby person at the entrance with rescue equipment and continuous communication)
💡 Entry into an enclosed space requires a standby person at the entrance, continuous communication and rescue equipment including breathing apparatus, so that immediate rescue is possible. Solo entry is a principal cause of multiple fatalities.
✗
Question 26. What does SOLAS require as regards the language of certificates?
Your Answer: (Not answered)
Correct Answer: C (They must be drawn up in the official language of the issuing State with a translation into English, French or Spanish)
💡 SOLAS I/5 requires certificates to be in the official language of the issuing State with a translation into English, French or Spanish, so that port States can verify them. A single language alone does not comply.
✗
Question 27. A PSCO checked the continuous synopsis record against the ship's history. What changes must the CSR record?
Your Answer: (Not answered)
Correct Answer: D (Significant events such as changes of name, flag, company, recognised organisation and class)
💡 SOLAS XI-1/5 requires the CSR to record the ship's history and significant changes, including changes of name, flag, company, recognised organisation and class, so the record is traceable. Incomplete or out-of-date entries are a deficiency.
✗
Question 28. Which is the 4 MHz band DSC distress frequency among the HF frequencies?
Your Answer: (Not answered)
Correct Answer: A (4207.5 kHz)
💡 HF DSC distress frequencies are 4207.5, 6312, 8414.5, 12577 and 16804.5 kHz. 2187.5 kHz is an MF frequency and 6312 kHz belongs to the 6 MHz band.
✗
Question 29. The sewage treatment plant is found not in operation and untreated sewage is being discharged directly. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Discharging untreated sewage does not meet the rules, a pollution prevention deficiency)
💡 Discharge of sewage must meet the applicable rules, that is, be treated by an approved treatment plant and meet the discharge conditions, or be discharged as permitted beyond the specified distance. Direct discharge of untreated sewage with the plant not running does not meet pollution prevention requirements and is a deficiency to be corrected.
✗
Question 30. What is required of drinking water containers in survival craft?
Your Answer: (Not answered)
Correct Answer: D (Hygienic containers preventing contamination, with the water renewed as prescribed)
💡 SOLAS requires survival craft to have hygienic containers for fresh water, preventing contamination and deterioration, with the water renewed at the prescribed servicing intervals. Water not renewed for a long time becomes undrinkable and affects survival.
✗
Question 31. For a passenger ship, within what time after a loss of propulsion shall the ship be able to restore propulsion?
Your Answer: (Not answered)
Correct Answer: A (30 minutes)
💡 SOLAS II-1/26: passenger ships shall restore propulsion within 30 minutes of a dead-ship condition.
✗
Question 32. Where must the remote controls of quick closing valves be located?
Your Answer: (Not answered)
Correct Answer: C (Outside the machinery space in an accessible position, clearly marked)
💡 SOLAS requires the remote controls of quick closing valves to be located outside the machinery space in a readily accessible and clearly marked position, so fuel can be shut off even if the space is on fire and cannot be entered.
✗
Question 33. Who issues the Safety Management Certificate?
Your Answer: (Not answered)
Correct Answer: B (The Administration or its recognized organization)
💡 The Administration or its recognized organization.
✗
Question 34. What is the relationship between the emergency switchboard and the main switchboard under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (The emergency switchboard is supplied from the emergency source, normally the emergency generator or battery, with appropriate interconnection to the main switchboard)
💡 SOLAS requires the emergency switchboard to be supplied from the emergency source, the emergency generator or battery, with appropriate interconnection to the main switchboard for normal conditions, while remaining independently supplied if the main source fails.
✗
Question 35. What does SOLAS address regarding fixed fire detection in ro-ro spaces?
Your Answer: (Not answered)
Correct Answer: B (A fixed fire detection and fire alarm system capable of detecting a fire in the vehicle space promptly)
💡 SOLAS requires ro-ro and vehicle spaces to have a fixed fire detection and fire alarm system. Because these spaces are large and vehicles carry fuel, fire spreads rapidly, and periodic rounds alone would not detect it in time.
✗
Question 36. Control stations shall be bounded by which type of division for protection in a fire?
Your Answer: (Not answered)
Correct Answer: A (A class divisions)
💡 SOLAS II-2/9 requires control stations to be bounded by A class divisions.
✗
Question 37. From where shall the valves of fuel oil tanks be capable of being closed?
Your Answer: (Not answered)
Correct Answer: A (Remotely from outside the space)
💡 SOLAS requires remote closing from outside the space so the fuel supply can be shut off in case of fire.
✗
Question 38. What periodic testing does the bilge system require?
Your Answer: (Not answered)
Correct Answer: D (Periodic water tests confirming that each compartment suction drains effectively, with strainers and valves checked)
💡 SOLAS and good practice require periodic water tests of the bilge system, confirming that the suction in each compartment drains effectively, that strainers are clear and valves operate reliably, with the results recorded, preventing the system from failing when needed.
✗
Question 39. The second officer drafts the quarterly drill plan: "muster monthly, brief on the equipment, everyone to the station, no boat actually lowered." Measured against the SOLAS chapter III drill frequencies, what is missing?
Your Answer: (Not answered)
Correct Answer: A (every lifeboat should be launched with its assigned crew at intervals not exceeding 3 months and manoeuvred with them, and launched with at least two crew at intervals not exceeding 6 months)
💡 The frequencies are easy to mix up: launching with the assigned crew and manoeuvring at intervals within 3 months, launching with two or more crew within 6 months. The monthly abandon-ship and fire drill is a separate layer and neither substitutes for the other, and an annual survey of the appliances says nothing about the crew's ability to get the boat down.
✗
Question 40. When loading solid bulk cargoes liable to liquefy, care must be taken to prevent:
Your Answer: (Not answered)
Correct Answer: B (Water accumulation in the holds)
💡 Accumulated water can cause liquefaction, so trimming and drainage are essential.
✗
Question 41. If a conversion reduces the lifeboats from two per side to one, what does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (Assessment and approval by the Administration or classification society beforehand, confirming the capacity requirement is still met)
💡 SOLAS requires changes to the life-saving appliance arrangement to be assessed and approved by the Administration or the classification society, confirming that the requirements for capacity per side, rescue boat and equipment are still met. Reducing the lifeboats without authority means the ship cannot ensure all persons can escape if one side is lost.
✗
Question 42. How should training needs be identified and met?
Your Answer: (Not answered)
Correct Answer: C (Identified from the operation of the system, drills and inspections and then delivered)
💡 The ISM Code and STCW require the company and the ship to identify training needs from drill assessments, findings at inspection and the analysis of accidents and near misses, such as unfamiliarity with equipment or unclear emergency duties, and to organise targeted training and assessment, so that training matches the actual need.
✗
Question 43. What do SOLAS V and COLREG require when navigating in a narrow channel?
Your Answer: (Not answered)
Correct Answer: A (Keep as near to the outer limit on the starboard side as is safe and practicable, at a safe speed with an adequate look-out)
💡 COLREG Rule 9 requires a vessel in a narrow channel to keep as near to the outer limit on her starboard side as is safe and practicable, at a safe speed with an adequate look-out. High speed or occupying any part of the channel greatly increases the risk of collision.
✗
Question 44. For free-fall lifeboats, drills shall include:
Your Answer: (Not answered)
Correct Answer: D (a free-fall launch at the required interval or an equivalent approved method)
💡 SOLAS III/19 requires free-fall lifeboats to be free-fall launched at the prescribed interval or by an approved equivalent method.
✗
Question 45. What do SOLAS and good practice require when radar and other radio equipment interfere with one another?
Your Answer: (Not answered)
Correct Answer: D (Identify the source and take measures such as adjusting antenna positions or settings so that all equipment works normally)
💡 Interference between equipment, such as same frequency radar or VHF and other transmitters, affects target presentation and communication. The cause should be found and removed by adjusting antenna positions, using filters or changing settings. Simply switching off the affected equipment is not acceptable.
✗
Question 46. Who provides ice information services?
Your Answer: (Not answered)
Correct Answer: D (The coastal State authority or designated service)
💡 The coastal State authority or a designated service.
✗
Question 47. What must be provided in the steering gear compartment under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (Arrangements to control the steering gear and to operate the machinery on emergency)
💡 SOLAS requires the steering gear compartment to have arrangements for controlling the steering gear and for operating the machinery on emergency, such as emergency stopping, making it an emergency control centre.
✗
Question 48. What is the principal safety hazard of a fixed CO2 system?
Your Answer: (Not answered)
Correct Answer: B (Asphyxiation of personnel)
💡 CO2 displaces oxygen, so personnel must be clear and alarms given before release.
✗
Question 49. What is required when new piping is passed through a fire division during a conversion?
Your Answer: (Not answered)
Correct Answer: D (Execute the approved penetration sealing arrangement, updating the fire control plan and records)
💡 New penetrations of a fire division require the approved penetration sealing arrangement to be used, with approved seals of equivalent fire rating, while the fire control plan and records are updated and the work verified by the classification society. A plain hole or cement sealing destroys the fire integrity of the division.
✗
Question 50. What do SOLAS and the Load Line Convention address regarding the height of air pipe openings on deck?
Your Answer: (Not answered)
Correct Answer: A (The height must be as prescribed, preventing sea water entering the tanks when the deck is swept)
💡 SOLAS and the Load Line Convention require air pipe openings on the freeboard deck and superstructure deck to reach the prescribed height, so that sea water does not readily enter the tanks when the deck is swept or the ship lists, preventing loss of stability.
✗
Question 51. What shall embarkation arrangements for survival craft ensure?
Your Answer: (Not answered)
Correct Answer: D (Rapid and orderly boarding and ease of launching)
💡 They shall permit rapid, orderly embarkation and launching.
✗
Question 52. What is the usual maximum validity of a Cargo Ship Safety Radio Certificate?
Your Answer: (Not answered)
Correct Answer: B (Five years, with periodical surveys)
💡 Under SOLAS I/12 the Cargo Ship Safety Radio Certificate has a usual validity of not more than five years, with periodical surveys as required. The performance and provision of the radio installation, including distress alerting, communications and the reserve source of energy, are the focus of the survey.
✗
Question 53. A survey found the nautical publications on board out of date. What does SOLAS address?
Your Answer: (Not answered)
Correct Answer: C (A deficiency; publications must be kept corrected up to date, as out-of-date information affects safety of navigation)
💡 SOLAS V/27 requires charts and nautical publications to be kept corrected to the latest information and they are checked at survey. Out-of-date publications are a deficiency affecting safety of navigation, particularly in confined waters and on an unfamiliar coast, where they create a risk of grounding.
✗
Question 54. Which tanks are normally excluded from ballast use?
Your Answer: (Not answered)
Correct Answer: C (Fuel, lubricating oil and fresh water tanks, preventing contamination and cross-connection)
💡 SOLAS and MARPOL prohibit fuel, lubricating oil and fresh water tanks from being used as ballast tanks, preventing ballast water from cross-connecting with oils and causing pollution, or oil entering the ballast system and affecting equipment. Dedicated ballast tanks and cargo oil tanks are treated separately under MARPOL.
✗
Question 55. What should be done with firefighter's outfits after use?
Your Answer: (Not answered)
Correct Answer: D (Clean, dry, inspect for damage and return to stowage, replacing defective parts promptly)
💡 After use, including in drills, firefighter's outfits should be cleaned, dried and inspected for damage such as torn clothing, low cylinder pressure or perished face masks, with defective parts replaced and the outfit returned to its stowage, ready for the next use.
✗
Question 56. Subdivision and damage stability keep a passenger ship afloat after damage. What is the basic assumption of the flooding calculation under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (Flooding of an assumed group of adjacent compartments is considered)
💡 SOLAS requires the flooding calculation to consider an assumed extent of damage affecting a group of adjacent compartments, verifying the ship's survivability in that condition. It is neither single-compartment damage nor flooding of the whole ship.
✗
Question 57. What must the enclosed space entry testing record contain under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (The date, location, parameters tested and results, and the issue of the permit)
💡 SOLAS and the IMO resolutions require records of enclosed space entry testing and permits, including the date, the space, the parameters tested — oxygen, toxic and flammable gases — the results and the permit issued, for traceability and inspection.
✗
Question 58. What safety precautions apply when using a CO2 extinguisher?
Your Answer: (Not answered)
Correct Answer: A (Hold the insulated handle to avoid cold burns and leave a poorly ventilated space promptly after use to avoid asphyxiation)
💡 CO2 discharges at a very low temperature, so the insulated handle should be held to avoid cold burns. CO2 displaces oxygen, so after heavy use in a confined space personnel should leave promptly and the space be ventilated, avoiding asphyxiation.
✗
Question 59. How shall the number and capacity of lifeboats on a passenger ship be determined?
Your Answer: (Not answered)
Correct Answer: B (To accommodate the total number of persons on board)
💡 The total capacity shall accommodate all persons on board.
✗
Question 60. What emergency supplies are required in polar waters?
Your Answer: (Not answered)
Correct Answer: D (Sufficient warm clothing, emergency food and water, heating means and emergency lighting)
💡 The Polar Code requires emergency supplies suited to the polar environment: ample warm clothing and thermal protection, emergency food and water, means of heating such as a spare heater, emergency lighting and communication equipment, in view of the long search and rescue response times.
✗
Question 61. What separation is required between control stations such as the bridge or fire control station and accommodation spaces?
Your Answer: (Not answered)
Correct Answer: A (Normally A-60 or A-30 class divisions, so the control station remains usable in a fire)
💡 Control stations provide command and fire control functions in an emergency, so SOLAS requires A-60 or A-30 boundaries with accommodation spaces according to their position, ensuring they remain usable.
✗
Question 62. What does SOLAS V/34 require of the master when using a ships' routeing system?
Your Answer: (Not answered)
Correct Answer: A (To use the system in accordance with the relevant rules, at a safe speed and with good seamanship)
💡 Ships must follow routeing systems; the master must apply them with a safe speed and good seamanship and may not depart from them simply to shorten the passage.
✗
Question 63. On what basis must rations in a lifeboat be provided under SOLAS III?
Your Answer: (Not answered)
Correct Answer: C (For the rated number of persons for the prescribed number of days, at the specified energy value per person)
💡 SOLAS III requires rations for the rated capacity for the prescribed number of days at a specified energy value per person, not for the actual complement and not for one day only.
✗
Question 64. The voyage plan shall include:
Your Answer: (Not answered)
Correct Answer: A (a berth-to-berth plan giving due consideration to navigational hazards including safe speed)
💡 SOLAS V/34: the voyage plan covers the whole passage from berth to berth, giving due consideration to navigational hazards and safe speed.
✗
Question 65. What measures prevent persons falling overboard?
Your Answer: (Not answered)
Correct Answer: C (Guard rails and lifelines, non-slip and well drained decks, good lighting and avoiding unnecessary deck work in heavy weather)
💡 Preventing a person from going overboard requires measures in combination: guard rails and lifelines at the sides, decks kept non-slip and well drained, lighting improved at night and in heavy weather, unnecessary deck work avoided and lifejackets and harnesses worn as required, reducing the risk.
✗
Question 66. What is the purpose of the automatic closing and hold-back release arrangements of fire doors?
Your Answer: (Not answered)
Correct Answer: D (To enable the doors to be held open for passage in normal service and to close automatically on a fire alarm to maintain the fire division)
💡 Under SOLAS II-2/9 fire doors required to be self-closing should be fitted with automatic closing arrangements and, where necessary, hold-back release arrangements that release the door on detection of a fire. The door may be held open in normal service for passage and ventilation and closes automatically on a fire alarm to maintain the fire division. The arrangements should be tested regularly.
✗
Question 67. What does SOLAS address regarding updating structural strength information for a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (Updated promptly and approved when the structure or loading limitations change)
💡 SOLAS requires the structural strength and loading limitation information of a bulk carrier to be updated promptly and approved by the classification society or the Administration when the structure, equipment or loading conditions change significantly. The crew must not modify it themselves.
✗
Question 68. What watch must be maintained after a distress alert is transmitted?
Your Answer: (Not answered)
Correct Answer: A (A watch on the appropriate distress frequency, ready to answer and establish communication)
💡 After transmitting a distress alert the ship should keep a watch on the appropriate distress and safety frequency, such as VHF channel 16, MF 2182 kHz or the satellite equipment, ready to answer other ships or coast stations, so that distress traffic can be established and assistance obtained as quickly as possible.
✗
Question 69. What are the common risks in launching and recovering survival craft?
Your Answer: (Not answered)
Correct Answer: A (Inadvertent operation of the release gear dropping the boat and injuring persons, and persons being crushed between the falls and the boat)
💡 The principal risks in launching and recovering a lifeboat include the release gear operating inadvertently and dropping the boat, persons being crushed between the falls and the boat and the boat striking the ship's side. Procedures should be strictly followed, coordination maintained and positions chosen with care.
✗
Question 70. What does the monthly check and test of radio equipment normally include?
Your Answer: (Not answered)
Correct Answer: B (A more comprehensive performance test with records, including checks of the reserve source of energy)
💡 SOLAS and the GMDSS performance standards require a more thorough monthly check and performance test, including verification of the capacity of the reserve source and the change-over to emergency supply, with records kept.
✗
Question 71. After a distress alert sent by digital selective calling, on which frequency is the follow-up distress traffic made?
Your Answer: (Not answered)
Correct Answer: D (very high frequency moving to sixteen, medium frequency to two thousand one hundred and eighty-two kilohertz)
💡 Selective calling only puts the alert and the position out; the channel itself is not for speech. A very high frequency alert goes out on seventy and the traffic that follows is made on sixteen; the medium frequency alert is sent on two thousand one hundred and eighty-seven and a half kilohertz with the traffic on two thousand one hundred and eighty-two, high frequency having its own distress and safety frequencies. An alert is normally acknowledged by radiotelephony, and acknowledgements and relays are made on the frequency the rules assign, the alerting channel being kept clear. Treating seventy as a speech channel confuses the calling and the telephony sides of the system.
✗
Question 72. Among the information entered into AIS, which is static?
Your Answer: (Not answered)
Correct Answer: B (The IMO number, call sign and ship's name, being fixed particulars of the ship)
💡 AIS static information includes the IMO number, call sign, name and type of ship, entered at installation and rarely changed. Position, course and speed are dynamic; destination and ETA are voyage related.
✗
Question 73. What does SOLAS address regarding protection of hot surfaces in machinery spaces?
Your Answer: (Not answered)
Correct Answer: D (Surfaces above the prescribed temperature must be insulated or guarded, preventing ignition of oil on contact)
💡 SOLAS requires piping and equipment surfaces above the prescribed temperature, such as 220 degrees Celsius, to be insulated or guarded, preventing fuel or lubricating oil from being ignited on contact.
✗
Question 74. What is the hazardous characteristic of a Group A solid bulk cargo under the IMSBC Code?
Your Answer: (Not answered)
Correct Answer: B (It may liquefy if shipped above the TML, causing cargo shift and capsize)
💡 Group A cargoes contain fines and moisture and may liquefy, causing a shift of cargo and loss of stability. The hazard is physical, not chemical.
✗
Question 75. What does SOLAS V/23 require of the ship regarding pilot ladders?
Your Answer: (Not answered)
Correct Answer: B (Regular inspection and maintenance in good condition, with an escort arranged during embarkation and disembarkation)
💡 SOLAS V/23 requires the ship to inspect and maintain the pilot transfer arrangements regularly with records kept, and to arrange an escort during embarkation and disembarkation.
✗
Question 76. A portable fire extinguisher is found without its securing bracket and may topple and be damaged in rough weather. The finding is?
Your Answer: (Not answered)
Correct Answer: C (Extinguishers should be properly secured and readily available; failure to secure is a deficiency to be corrected)
💡 A portable fire extinguisher should be secured in its designated position so that it is readily available and does not topple, collide and be damaged or cause injury as the ship rolls. Failure to secure it affects both availability and the risk of damage. It is a deficiency to be corrected.
✗
Question 77. The navigation lights are found not to meet the required position, colour or arc of visibility. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Non-compliant navigation lights affect the ability of other ships to judge the situation, a deficiency to be corrected)
💡 The position, colour and arc of visibility of the navigation lights, such as masthead, sidelights and stern light, must meet the requirements so that other ships can judge the heading and movement of the vessel from the correct bearing and distance. Non-compliance may lead to misjudgement and increased risk of collision. It is a deficiency to be corrected.
✗
Question 78. What is required for liferafts to float free when the ship sinks?
Your Answer: (Not answered)
Correct Answer: C (Their stowage and securing must allow them to float free, unhindered by lashings or structure)
💡 SOLAS requires liferafts to be stowed and secured so that they can float free if the ship sinks, with the hydrostatic release unit and weak link correctly arranged. Additional lashings or structural obstruction would prevent the raft floating free, a serious deficiency.
✗
Question 79. What should be done with a fire hose after use?
Your Answer: (Not answered)
Correct Answer: A (Clean and dry it, then roll and stow it in the proper manner in place, keeping it ready for use)
💡 After use a fire hose should be washed free of oil and salt water, dried and then rolled and stowed in the proper manner in its position, preventing rot and ageing which affect pressure resistance. Stowing it damp or exposing it long term shortens its life.
✗
Question 80. A lifeboat shall be provided with at least how many buoyant smoke signals?
Your Answer: (Not answered)
Correct Answer: B (2)
💡 SOLAS III/34 requires at least two buoyant smoke signals in a lifeboat.
✗
Question 81. What does SOLAS address regarding fire doors in an enclosed escape route?
Your Answer: (Not answered)
Correct Answer: C (Self-closing fire doors must be fitted, maintaining the fire integrity of the route)
💡 SOLAS requires self-closing fire doors in an enclosed escape route, allowing normal passage and closing automatically in a fire to preserve the fire integrity of the route. Ordinary or removed doors destroy that protection.
✗
Question 82. What does SOLAS require regarding the starting arrangements for fire pumps?
Your Answer: (Not answered)
Correct Answer: C (They must be capable of remote starting from the bridge or fire control station, with means at the hydrants to start a pump)
💡 SOLAS requires fire pumps to be capable of remote starting by the watchkeeper from the bridge or a fire control station, with means at the hydrants to start a pump, so water is available quickly in a fire.
✗
Question 83. Which group of sound signals constitutes the abandon ship signal?
Your Answer: (Not answered)
Correct Answer: D (Seven short blasts followed by one prolonged)
💡 SOLAS III/9: the abandon ship signal is seven short blasts followed by one prolonged blast.
✗
Question 84. What is the principal characteristic of class 3 dangerous goods?
Your Answer: (Not answered)
Correct Answer: C (Flammable liquids, whose vapour can be ignited at ambient temperature)
💡 Class 3 of the IMDG Code covers flammable liquids, being liquids which give off flammable vapour at or below their flashpoint. Explosives are class 1 and oxidising substances class 5.
✗
Question 85. What does SOLAS permit when a certificate expires while the ship is at sea?
Your Answer: (Not answered)
Correct Answer: B (An extension of not more than three months in specified circumstances, so the ship may complete the voyage or reach the port of survey)
💡 SOLAS I/14 permits an extension of not more than three months in the specified circumstances, where a certificate expires during a voyage and the ship has not been surveyed in time, so that she may reach the port where she is to be surveyed. The extension must be within the rules and recorded.
✗
Question 86. What is the basic requirement for cargo carriage under SOLAS VI?
Your Answer: (Not answered)
Correct Answer: D (Cargo shall be loaded, stowed and secured with regard for stability and structural strength)
💡 Loading, stowage and securing shall not endanger the ship's safety or stability.
✗
Question 87. What is the servicing interval for inflatable liferafts?
Your Answer: (Not answered)
Correct Answer: A (Not exceeding 12 months, at an approved servicing station)
💡 Inflatable liferafts must be serviced at an approved station at intervals not exceeding 12 months, unless a longer interval is approved for specially designed rafts.
✗
Question 88. What is the correct attitude to AIS information in restricted visibility?
Your Answer: (Not answered)
Correct Answer: A (Use it as an aid but still rely on radar and visual look-out to judge the risk of collision)
💡 The IMO circulars make clear that AIS is an aid whose data may be delayed, erroneous or absent, for example if not correctly entered or if the target does not carry AIS. The risk of collision must still be judged principally from radar observation and visual look-out, and an avoiding decision must not rest on AIS alone.
✗
Question 89. In a bridge design review for a new multi-purpose vessel the yard submits four statements: (1) five forward windows with frames kept as narrow as practicable; (2) a refrigeration compressor casing at the conning position blocking about 15 degrees ahead; (3) in ballast the sea surface ahead of the bow is not visible from the conning position; (4) fixed wipers with washing and defrosting on the forward windows. Which statements are non-compliant with SOLAS chapter V?
Your Answer: (Not answered)
Correct Answer: D (items 2 and 3)
💡 The permitted blind sector forward of the conning position is limited, so a 15-degree obstruction ahead is a classic layout error, and the field must be met in both loaded and ballast conditions — a bare claim that the bow can be seen is not enough. Narrow frames, fixed wipers and wash/defrost are what V/22 expects, so 1 and 4 comply.
✗
Question 90. At what angle of list must the launching appliance be able to release the lifeboat safely?
Your Answer: (Not answered)
Correct Answer: D (37.5°)
💡 SOLAS III/31.2: launching appliances shall permit safe launching with a list of 37.5° and trim of 10°.
✗
Question 91. Under the ISM Code, the company shall designate person(s) (DPA) to be responsible for:
Your Answer: (Not answered)
Correct Answer: C (linking the company with the ship on safety and pollution prevention matters)
💡 SOLAS IX/6: the company shall designate person(s) (DPA) to link the company with the ship on safety and pollution prevention matters.
✗
Question 92. After an accidental DSC distress alert is transmitted, what is the correct action?
Your Answer: (Not answered)
Correct Answer: A (Immediately transmit a cancellation to the relevant coast station or RCC)
💡 SOLAS and ITU procedures require an accidental alert to be cancelled immediately by a follow-up message to the coast station or rescue coordination centre. It must never be ignored.
✗
Question 93. Which Code governs the construction of ships carrying liquefied gases in bulk?
Your Answer: (Not answered)
Correct Answer: B (The IGC Code)
💡 The IGC Code.
✗
Question 94. What does the Polar Code address regarding emergency preparedness in polar waters?
Your Answer: (Not answered)
Correct Answer: A (Recognise the long distances and response times and strengthen self-help capability and emergency supplies)
💡 The Polar Code requires recognition that search and rescue resources in polar regions are limited, response times long and weather conditions severe, so the ship must strengthen her self-help capability, carry ample emergency supplies such as food, thermal protection and fuel and have suitable emergency procedures.
✗
Question 95. With regard to openings in the collision bulkhead, which is correct?
Your Answer: (Not answered)
Correct Answer: D (the number of openings shall be reduced to a minimum and no doors or manholes shall be fitted)
💡 SOLAS II-1/12 requires openings in the collision bulkhead to be reduced to a minimum, with no doors, manholes or ventilation ducts.
✗
Question 96. What speed and endurance must a powered rescue boat have under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (At least 6 knots for not less than 4 hours)
💡 SOLAS requires a powered rescue boat to maintain at least 6 knots for not less than 4 hours in calm water with its full complement aboard, enabling it to sustain rescue operations.
✗
Question 97. Lifeboat and liferaft launching appliances shall be capable of operating when the ship is listed by:
Your Answer: (Not answered)
Correct Answer: C (not more than 20°)
💡 SOLAS III/16 requires launching appliances to operate with the ship listed up to 20°.
✗
Question 98. What is the correct radiotelephony distress procedure?
Your Answer: (Not answered)
Correct Answer: A (Say MAYDAY three times, then give the ship's name, position and nature of distress and wait for an answer)
💡 The distress call comprises MAYDAY three times, followed by the name and call sign of the ship, her position, the nature of the distress and the assistance required, then waiting for an answer. Channel 70 must not be used for speech.
✗
Question 99. Why does SOLAS require firefighter's outfits to be stowed in more than one location?
Your Answer: (Not answered)
Correct Answer: A (To prevent a fire in one place from making all the outfits unavailable, so they are distributed)
💡 SOLAS requires firefighter's outfits to be stowed in two or more positions because, if they were all in one place, a fire there would make every outfit unavailable and firefighting and rescue could not proceed.
✗
Question 100. A company is reviewing the scope statement of a Cargo Securing Manual. Which wording should be adopted?
Your Answer: (Not answered)
Correct Answer: A (the securing of cargo units such as containers, vehicles and portable tanks; solid and liquid bulk fall under their own codes, the manual being Administration-approved and available on board)
💡 The manual covers cargo units; solid and liquid bulk cargoes fall under their own codes and cannot be mixed in. It must be approved and kept available on board, and it does not replace the loading calculation. Narrowing it to one ship type, or leaving it to the Master's discretion, fails VI/5.