Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. A crew member's actual rank does not match the certificate held, a junior certificate being used for a senior post. The finding is?
Your Answer: (Not answered)
Correct Answer: A (Serving with a mismatched certificate is an illegal manning arrangement, a serious deficiency to be corrected)
💡 A crew member's certificate of competency should match the rank held. Using a lower-grade certificate for a higher post is an illegal manning arrangement. It weakens the capability of the post and violates the safe manning requirements. It is a serious deficiency to be corrected, normally by changing personnel or supplying properly certificated crew.
✗
Question 2. Where shall an alarm be given on failure of the steering gear power or control system?
Your Answer: (Not answered)
Correct Answer: B (On the bridge)
💡 An audible and visual alarm shall be given on the bridge.
✗
Question 3. A PSCO checked the operation of navigation lights. What additional requirement does SOLAS impose?
Your Answer: (Not answered)
Correct Answer: B (An indicator or failure alarm for navigation lights on the bridge)
💡 SOLAS requires an indicator or alarm on the bridge for navigation lights, so that the watchkeeper learns at once of a failure and can act, avoiding misinterpretation by other ships.
✗
Question 4. What quality requirement applies to the foam concentrate of a fixed foam system?
Your Answer: (Not answered)
Correct Answer: B (It must be approved, used within its shelf life and periodically tested for performance)
💡 SOLAS and the related standards require approved foam concentrate used within its shelf life, with periodic sampling to verify expansion and extinguishing performance. Deteriorated or out-of-date concentrate will fail when needed.
✗
Question 5. What is required for electrical equipment in areas of machinery spaces where flammable gas may accumulate?
Your Answer: (Not answered)
Correct Answer: B (Explosion-protected equipment or effective ventilation with gas detection, preventing ignition by electrical sparks)
💡 In spaces such as purifier rooms and fuel pump rooms where flammable gas may accumulate, explosion-protected equipment or effective ventilation with gas detection is required, preventing an electrical spark from becoming a source of ignition.
✗
Question 6. What closed-loop management of hazards is required?
Your Answer: (Not answered)
Correct Answer: B (Assign responsibility, measures and deadlines for each hazard found and track it to closure, with reasons recorded for items not completed)
💡 Hazards found at inspections, drills, reports and internal audits should be managed in a closed loop: assigning the person responsible and a deadline, implementing the measures, verifying the effect, closing the item and recording it. Items not completed on time should have the reason stated, the risk assessed and a new arrangement made, preventing hazards from persisting.
✗
Question 7. The shipper shall provide the ship with cargo information before loading, including:
Your Answer: (Not answered)
Correct Answer: A (information necessary for proper stowage and securing, such as weight and stowage factor)
💡 SOLAS VI/5: the shipper shall provide, before loading, information necessary for proper stowage and securing such as weight and stowage factor.
✗
Question 8. A section of the fire detection system fails to alarm during testing. What should be done?
Your Answer: (Not answered)
Correct Answer: C (Establish the cause at once, such as a failed detector, broken wiring or incorrect zoning, and repair it)
💡 A section that does not alarm means a fire there would not be detected in time. The cause must be established at once, whether a failed detector, broken wiring, incorrect zoning or an inhibited circuit, and repaired. Disabling the section or relying on another leaves a serious latent hazard.
✗
Question 9. What is required for position monitoring when navigating in restricted waters?
Your Answer: (Not answered)
Correct Answer: B (Cross-check the position using several means such as visual bearings, radar and GPS, detecting any discrepancy early)
💡 SOLAS and good seamanship require the position in restricted waters to be cross-checked by several means, such as visual bearings, radar and GPS, detecting errors early. Reliance on a single means may lead to grounding through equipment error.
✗
Question 10. What must the PWOM contain regarding operational measures for polar waters?
Your Answer: (Not answered)
Correct Answer: A (Ice assessment in voyage planning, ship capability limitations, emergency procedures and training requirements)
💡 The Polar Water Operational Manual must cover voyage planning, ice assessment, the ship's ice class capabilities and limitations, operation of equipment in low temperature, emergency procedures and training, guiding the master's decisions in ice.
✗
Question 11. How should the hands-on ability of the crew be assessed?
Your Answer: (Not answered)
Correct Answer: D (Assessed through practical drills on critical equipment, with training strengthened where it is weak)
💡 The ISM Code and STCW require the practical ability of the crew on critical equipment to be assessed through drills, such as donning breathing apparatus, using extinguishers and hoses, preparing to launch a lifeboat, emergency steering and damage control operations, with training strengthened where skill is lacking, so that the ability is genuinely usable.
✗
Question 12. What fire detection is required in spaces carrying dangerous goods?
Your Answer: (Not answered)
Correct Answer: C (Detection suited to the cargo, with gas detection for certain cargoes)
💡 SOLAS and the IMDG Code require spaces carrying dangerous goods to have detection suited to the cargo, such as smoke, heat or gas detection, with gas detection and alarm where flammable gas may be released, so that an incipient fire or a leak is detected promptly.
✗
Question 13. What certificate must a ship operating in polar waters carry?
Your Answer: (Not answered)
Correct Answer: C (A Polar Ship Certificate)
💡 SOLAS XIV/3 requires ships operating in polar waters to hold a Polar Ship Certificate attesting compliance with the relevant parts of the Polar Code.
✗
Question 14. Which certificate shall a ship hold under the ISPS Code?
Your Answer: (Not answered)
Correct Answer: A (ISSC)
💡 The International Ship Security Certificate.
✗
Question 15. In the subdivision of a passenger ship, what does the "subdivision load line" mean?
Your Answer: (Not answered)
Correct Answer: D (An assumed load line used to determine subdivision requirements, not the ship's actual service load line)
💡 The subdivision load line is an assumed load line used in determining subdivision requirements such as bulkhead positions and the subdivision index. It is a different concept from the summer or tropical load lines actually used in service.
✗
Question 16. What are the key points in starting a lifeboat engine?
Your Answer: (Not answered)
Correct Answer: A (Prepare for starting before launching as prescribed, then start promptly after entering the water and check the cooling water discharge)
💡 Before launching, the boat engine should be prepared as the manufacturer prescribes, such as checking fuel, battery and cooling water, and started promptly once in the water with the cooling water discharge and smooth running checked, so that the boat is under control. Preparing only after entering the water delays the getaway.
✗
Question 17. A ship was detained by PSC and, after rectification, released following re-inspection by a recognised organisation. Under SOLAS, who issues the relevant certificate?
Your Answer: (Not answered)
Correct Answer: C (The Administration or a person duly authorised by it)
💡 The power to issue certificates rests with the Administration. A recognised organisation may act only within the scope of a formal authorisation given by that Administration.
✗
Question 18. What should be noted about the use of distress signals during drills?
Your Answer: (Not answered)
Correct Answer: A (Signals should not be fired in a drill unless necessary; if fired, the direction and safety must be confirmed and the matter recorded)
💡 Distress signals are dangerous goods with a limited life. They are not normally fired in a drill, alternative means being used to check them. If firing is genuinely required, the direction and the safety of the surroundings must be confirmed, the bridge informed and the expenditure recorded, avoiding misunderstanding or danger.
✗
Question 19. What is the primary purpose of ships' routeing under SOLAS V/10?
Your Answer: (Not answered)
Correct Answer: B (To improve safety of navigation and reduce the risk of collision and grounding)
💡 SOLAS V/10 states that the purpose of ships' routeing is to improve safety of navigation and reduce the risk of collision, not to delimit jurisdiction or increase speed.
✗
Question 20. What should be done if a ship receives another's distress alert but cannot herself assist directly?
Your Answer: (Not answered)
Correct Answer: A (Relay the alert and reply promptly, explaining the situation and informing a coast station or rescue service if necessary)
💡 GMDSS procedure requires a ship receiving another's distress alert to reply promptly and explain the situation, such as her distance, capability and whether she can proceed, and to relay the alert to a coast station or rescue service. No response or ignoring it is not acceptable.
✗
Question 21. In which circumstances must the officer of the watch notify the master immediately?
Your Answer: (Not answered)
Correct Answer: B (In restricted visibility, on failure of machinery or steering gear, or on encountering a hazard to safety)
💡 STCW and SOLAS require the officer of the watch to call the master immediately in restricted visibility, on failure of machinery or steering gear, or on encountering anything that may endanger safety, or when in doubt.
✗
Question 22. What does SOLAS address regarding electrical equipment in a paint locker?
Your Answer: (Not answered)
Correct Answer: C (Explosion-protected equipment or no electrical equipment within the space)
💡 SOLAS requires explosion-protected equipment in a paint locker, or no electrical equipment inside it, such as lighting fitted outside, preventing an electrical spark from igniting paint vapour.
✗
Question 23. What is the principal concern of SOLAS XII regarding cargo hatch covers of bulk carriers?
Your Answer: (Not answered)
Correct Answer: B (They must remain weathertight and structurally adequate, preventing sea water entering holds and causing structural failure)
💡 SOLAS XII requires hatch covers of bulk carriers to be weathertight and of adequate strength. Failure of hatch covers allowing sea water into the holds is a major cause of structural failure and loss of bulk carriers.
✗
Question 24. Muster stations shall be located:
Your Answer: (Not answered)
Correct Answer: C (close to the embarkation station and readily accessible)
💡 SOLAS III/11 requires muster stations to be located near the embarkation stations and readily accessible.
✗
Question 25. The main functions of an Inmarsat ship earth station include:
Your Answer: (Not answered)
Correct Answer: C (distress alerting, communication and reception of maritime safety information)
💡 SOLAS IV/7 requires an Inmarsat ship earth station for distress alerting, communication and reception of MSI.
✗
Question 26. What are the usual transmit power settings of a ship's VHF radiotelephone?
Your Answer: (Not answered)
Correct Answer: A (1 watt (low) and 25 watts (high))
💡 A ship's VHF normally has two settings, one watt for low power and twenty-five watts for high power, low power being used for short-range communication to reduce interference and high power for long range or distress communication to ensure coverage. Selecting the right setting is a basic watchkeeping requirement.
✗
Question 27. What is required for coordinating mooring lines and tugs when unberthing?
Your Answer: (Not answered)
Correct Answer: D (Slack and let go the lines in the proper order while maintaining communication with tugs and the terminal, preventing lines from fouling the propeller)
💡 Lines should be let go in the proper order, normally the spring and breast lines first and the head and stern lines last, with communication maintained with the tugs and the terminal, preventing slack lines from being taken into the propeller and damaging the propulsion system.
✗
Question 28. A lifeboat shall be provided with at least how many hand flares?
Your Answer: (Not answered)
Correct Answer: B (6)
💡 SOLAS III/34 requires at least six hand flares in a lifeboat.
✗
Question 29. Which body is responsible for type approval of shipborne radio equipment?
Your Answer: (Not answered)
Correct Answer: D (The Administration or its recognized organization)
💡 Type approval is carried out by the Administration or its recognized organization.
✗
Question 30. A VDR shall record:
Your Answer: (Not answered)
Correct Answer: D (date/time, position, speed, heading, bridge audio and other data)
💡 SOLAS V/20: a VDR records date/time, position, speed, heading, radar images and bridge audio.
✗
Question 31. When encountering ice or icebergs, a ship shall:
Your Answer: (Not answered)
Correct Answer: B (navigate with caution, report as necessary and keep a safe distance)
💡 SOLAS V/31-32 requires monitoring of ice, cautious navigation and reporting.
✗
Question 32. What does SOLAS III/36 require for maintenance of survival craft and launching appliances?
Your Answer: (Not answered)
Correct Answer: C (A planned maintenance system on board in accordance with the manufacturer's instructions)
💡 SOLAS III/36 requires planned maintenance of survival craft and launching appliances on board in accordance with the manufacturer's instructions, with records kept. Breakdown maintenance alone is not acceptable.
✗
Question 33. What factors must a voyage plan consider under SOLAS and good practice?
Your Answer: (Not answered)
Correct Answer: A (Prohibited and restricted areas, shoal water and draught limits, traffic density, weather and tides, and emergency shelter)
💡 A voyage plan should consider prohibited and exercise areas, shoal water and draught limitations, traffic density, weather and tidal conditions and emergency shelter anchorages and alternative routes, making the passage safe and practicable with contingency arrangements.
✗
Question 34. What does SOLAS XII require regarding the sequence of loading or unloading bulk carriers?
Your Answer: (Not answered)
Correct Answer: A (An approved sequence complying with structural strength limitations must be used)
💡 SOLAS XII requires loading and unloading to follow an approved sequence within structural limits. Skipping holds or working for speed alone can overstress the hull.
✗
Question 35. What does 'international voyage' mean in SOLAS?
Your Answer: (Not answered)
Correct Answer: B (A voyage from a port in one country to a port outside that country)
💡 It means a voyage from a port of one country to a port outside that country.
✗
Question 36. If the Inmarsat equipment fails while a ship is in sea area A3, what alternative does SOLAS permit?
Your Answer: (Not answered)
Correct Answer: A (Using MF/HF equipment to meet the distress and safety communication requirements)
💡 Where the primary satellite equipment fails, the ship must use MF/HF to maintain distress and safety communication in sea area A3. Reliance on another ship or on repair is not acceptable.
✗
Question 37. What ventilation shall be provided for cargo spaces carrying dangerous goods?
Your Answer: (Not answered)
Correct Answer: B (Independent ventilation controllable according to the nature of the goods)
💡 Independent, controllable ventilation shall be provided.
✗
Question 38. When loading solid bulk cargoes liable to liquefy, care must be taken to prevent:
Your Answer: (Not answered)
Correct Answer: B (Water accumulation in the holds)
💡 Accumulated water can cause liquefaction, so trimming and drainage are essential.
✗
Question 39. What is required for the arrangement of two power units of the main steering gear?
Your Answer: (Not answered)
Correct Answer: D (Each must be controllable from the bridge separately, so that steering remains available if one fails)
💡 SOLAS requires the two power units of the main steering gear to be capable of separate control from the bridge or with automatic change-over, so that steering is retained if one fails. A shared control system could fail as one.
✗
Question 40. Within what time shall the emergency generator start and supply power automatically on loss of the main supply?
Your Answer: (Not answered)
Correct Answer: D (30 seconds)
💡 SOLAS II-1/44: the emergency generator shall start automatically within 30 seconds.
✗
Question 41. Why does SOLAS V/19.2.2 require a heading repeater at the steering position?
Your Answer: (Not answered)
Correct Answer: D (So that the helmsman can read the heading without leaving the steering position)
💡 SOLAS requires a heading repeater at the steering position so the helmsman can read the heading directly without leaving his station.
✗
Question 42. What isolation is required between ballast and cargo hold piping?
Your Answer: (Not answered)
Correct Answer: D (The ballast system must not be connected to the cargo spaces, preventing contamination or cross-connection affecting stability)
💡 SOLAS and MARPOL require the piping between the ballast system and the cargo holds or cargo tanks to be effectively isolated, by isolating valves, blanks or separate piping, preventing ballast water and cargo from cross-connecting, which would contaminate the cargo, cause abnormal stability or lead to an illegal discharge.
✗
Question 43. A pilot is boarding in a swell. What arrangement must the ship provide?
Your Answer: (Not answered)
Correct Answer: C (A pilot ladder complying with the standard, combined with an accommodation ladder where required)
💡 SOLAS V/23 requires the ship to provide safe means of embarkation and disembarkation for pilots, normally a compliant pilot ladder, combined with an accommodation ladder where the freeboard is large.
✗
Question 44. What navigational measures should the officer of the watch take in restricted visibility?
Your Answer: (Not answered)
Correct Answer: D (Engines ready for immediate manoeuvre, enhanced look-out and radar observation, reducing speed as required and using sound signals)
💡 COLREG Rule 19 and good seamanship require engines ready for immediate manoeuvre, an enhanced look-out and radar observation, reduction of speed or stopping where necessary and the prescribed sound signals, so that other vessels are warned in due time.
✗
Question 45. After a distress alert sent by digital selective calling, on which frequency is the follow-up distress traffic made?
Your Answer: (Not answered)
Correct Answer: D (very high frequency moving to sixteen, medium frequency to two thousand one hundred and eighty-two kilohertz)
💡 Selective calling only puts the alert and the position out; the channel itself is not for speech. A very high frequency alert goes out on seventy and the traffic that follows is made on sixteen; the medium frequency alert is sent on two thousand one hundred and eighty-seven and a half kilohertz with the traffic on two thousand one hundred and eighty-two, high frequency having its own distress and safety frequencies. An alert is normally acknowledged by radiotelephony, and acknowledgements and relays are made on the frequency the rules assign, the alerting channel being kept clear. Treating seventy as a speech channel confuses the calling and the telephony sides of the system.
✗
Question 46. What do SOLAS and the ISM Code address regarding safety meetings and training on board?
Your Answer: (Not answered)
Correct Answer: D (Regular safety training and meetings to raise crew awareness, with records kept)
💡 The ISM Code and good practice require regular safety meetings and training on board, dealing with the ship's own situation such as recent incidents, problems found in drills and new requirements, with records kept, raising the crew's safety awareness and practical ability.
✗
Question 47. What do SOLAS and the ISM Code require after equipment failure at sea?
Your Answer: (Not answered)
Correct Answer: B (Record the failure and the action taken, report to the company and, where required, to the Administration)
💡 SOLAS and the ISM Code require failures affecting safety to be recorded, including the time, nature of the failure, action taken and result, reported to the company as required and, where necessary, to the Administration or port State, as a basis for the operation of the system and later repair.
✗
Question 48. What should be noted about fog signals in restricted visibility?
Your Answer: (Not answered)
Correct Answer: A (Sound fog signals as COLREG prescribes and listen attentively to other vessels' signals to judge bearing and movement)
💡 In restricted visibility fog signals should be sounded as COLREG prescribes, for example one prolonged blast at intervals of not more than two minutes for a power-driven vessel under way, while listening carefully to other vessels' signals to judge their approximate bearing and movement, combined with radar observation. Sounding must not be delayed.
✗
Question 49. In addition to ventilation, what shall be fitted in paint lockers and flammable liquid stores?
Your Answer: (Not answered)
Correct Answer: D (A fixed fire-extinguishing system)
💡 SOLAS II-2/10.6.3: paint lockers and flammable liquid stores shall have a fixed fire-extinguishing arrangement.
✗
Question 50. After testing the steering gear, the officer shall confirm:
Your Answer: (Not answered)
Correct Answer: B (Rudder angles agree with orders and communication works)
💡 Confirm correct rudder indication and satisfactory communication, and record it in the log.
✗
Question 51. How do the fire requirements for vehicle and ro-ro spaces differ from ordinary cargo holds?
Your Answer: (Not answered)
Correct Answer: A (Because vehicles carry fuel and the spaces are large, a fixed extinguishing system and effective drainage are required)
💡 SOLAS II-2/20 lays down specific requirements for vehicle and ro-ro spaces, including fixed extinguishing systems and drainage, because vehicles carry fuel and fire spreads rapidly between them.
✗
Question 52. From what tonnage shall the main steering gear have two independent power units?
Your Answer: (Not answered)
Correct Answer: D (10000 GT)
💡 From 10000 GT and above.
✗
Question 53. What should be met for electrical equipment and operations in the cargo area of a tanker?
Your Answer: (Not answered)
Correct Answer: C (Explosion-protected equipment should be used and requirements such as gas testing, earthing and static protection observed to control ignition sources)
💡 In the cargo area of a tanker electrical equipment should be of the specified explosion-protected type and operations should observe requirements such as gas testing, effective earthing and protection against static electricity, including controlling flow rates and using anti-static equipment, controlling ignition sources and static discharge to prevent flammable gas from being ignited. Gas testing and a permit before operations are basic requirements.
✗
Question 54. What training does the ISPS Code require of the ship security officer?
Your Answer: (Not answered)
Correct Answer: B (Security training approved by the Administration, with the necessary knowledge and ability)
💡 ISPS Code Part A/18 requires the ship security officer to have approved security training covering security assessment, implementation of the plan and organisation of drills. Reading the plan or a verbal briefing is not sufficient.
✗
Question 55. An alarm was replaced but not entered in the equipment record. What does SOLAS address?
Your Answer: (Not answered)
Correct Answer: A (Changes of equipment must be entered in the record book and kept consistent with the certificate)
💡 SOLAS requires the equipment record, such as the record of equipment for the cargo ship safety equipment certificate, to reflect the equipment fitted and any changes, keeping the certificate, the record and the ship consistent. An unrecorded change breaks that consistency and affects the survey and validity.
✗
Question 56. After a ship is detained by PSC, what is the correct course of action?
Your Answer: (Not answered)
Correct Answer: D (Rectify the deficiencies before departure and apply for a re-inspection, fulfilling the duty to report to the flag State, the recognised organisation and the company)
💡 A detained ship should rectify the deficiencies before departure, or within the permitted period, apply for a port State re-inspection and be confirmed before leaving, and report to the flag State, recognised organisation and company as required with the rectification plan. Sailing without rectification aggravates the consequences and affects the future PSC record.
✗
Question 57. SOLAS requires that the main propulsion machinery be:
Your Answer: (Not answered)
Correct Answer: A (controllable from the navigation bridge and also from the machinery space)
💡 SOLAS II-1 requires the main propulsion machinery to be controlled from the navigation bridge as well as from the machinery space.
✗
Question 58. Which ships are subject to the Enhanced Survey Programme?
Your Answer: (Not answered)
Correct Answer: C (Bulk carriers and tankers)
💡 The ESP applies to bulk carriers and tankers, focusing on cargo and ballast tank areas.
✗
Question 59. What do SOLAS and good practice address regarding life-saving appliances during temporary repairs?
Your Answer: (Not answered)
Correct Answer: D (Life-saving appliances must remain available; if affected, compensating measures must be taken and accepted by the Administration)
💡 If life-saving appliances must be temporarily removed or are affected during repairs, compensating measures such as adjusting the arrangement, limiting the number of persons or restricting the area of work must be taken and accepted by the Administration or the classification society. The ship must not sail with the deficiency unaddressed.
✗
Question 60. What maintenance does the radar antenna and waveguide require?
Your Answer: (Not answered)
Correct Answer: A (Check that the antenna rotates freely, that the waveguide is not damp or damaged and that the antenna is not obstructed)
💡 Radar requires periodic checking that the antenna turning gear is free, that the waveguide and joints are not damp, damaged or waterlogged and that no new structure such as a mast or antenna obstructs the antenna, with performance checks as prescribed, keeping the detection capability of the radar.
✗
Question 61. What are the updating requirements for AIS voyage related information?
Your Answer: (Not answered)
Correct Answer: B (Entered at the start of the voyage and updated as soon as the information, such as destination, changes)
💡 AIS voyage related information such as draught, cargo, destination and ETA must be entered at the start of the voyage and updated promptly when it changes. Stale data misleads other ships and shore stations.
✗
Question 62. What does SOLAS address regarding the equilibrium condition in damage stability calculations?
Your Answer: (Not answered)
Correct Answer: B (After flooding the ship must satisfy the residual stability criteria in the equilibrium condition)
💡 SOLAS requires that, once the ship reaches equilibrium after flooding, taking account of the water entered and the resulting heel, the residual stability curve satisfies the prescribed criteria such as the range of righting levers and the maximum righting lever. Intact stability criteria alone are not a substitute.
✗
Question 63. The voyage plan shall include:
Your Answer: (Not answered)
Correct Answer: A (a berth-to-berth plan giving due consideration to navigational hazards including safe speed)
💡 SOLAS V/34: the voyage plan covers the whole passage from berth to berth, giving due consideration to navigational hazards and safe speed.
✗
Question 64. What is required when checking the rudder and oars of a lifeboat?
Your Answer: (Not answered)
Correct Answer: A (Check that the rudder and tiller are securely connected and that the oars are complete and secured)
💡 Checking the equipment should cover the rudder and tiller and the completeness and securing of the oars, ensuring the boat can still be handled by oars if the engine fails. A loose tiller or missing oars would directly affect survival after abandonment.
✗
Question 65. What medical first aid guidance must a ship carrying dangerous goods carry?
Your Answer: (Not answered)
Correct Answer: C (MFAG, the Medical First Aid Guide for use in accidents involving dangerous goods)
💡 SOLAS requires MFAG for the treatment of poisoning and chemical injury, while the EmS Guide addresses fire and spill response. The two serve different purposes and neither replaces the other.
✗
Question 66. A Safety Management Certificate (SMC) shall be issued for a period not exceeding:
Your Answer: (Not answered)
Correct Answer: C (5 years)
💡 SOLAS IX/4: a Safety Management Certificate shall be issued for a period not exceeding 5 years.
✗
Question 67. What familiarisation training is required for newly joined crew?
Your Answer: (Not answered)
Correct Answer: A (Completed before taking up duties, covering duties, the location and operation of equipment and emergency duties and procedures)
💡 The ISM Code and STCW require newly joined crew to complete familiarisation training before taking up their duties, covering their responsibilities on board, the location and operation of relevant equipment and emergency duties and procedures and safety and pollution prevention requirements, with records kept. Training after taking up duties is not acceptable.
✗
Question 68. What does SOLAS address regarding the fire and weathertight requirements for ventilators?
Your Answer: (Not answered)
Correct Answer: D (Closing devices must be fitted, able to shut off ventilation when required and maintain weathertightness)
💡 SOLAS requires ventilators to have closing devices that both shut off ventilation to control a fire and maintain weathertightness against the entry of sea water. A rain hood alone meets neither requirement.
✗
Question 69. What is required for route monitoring when using electronic charts?
Your Answer: (Not answered)
Correct Answer: B (Continuously monitor the deviation from the planned route, act on and acknowledge safety alarms and correct as necessary)
💡 When ECDIS is in use the deviation from the planned route should be monitored continuously and safety alarms such as off-track and approaching danger acted on and acknowledged, with course corrections as necessary. Setting the route and then neglecting to monitor it is not acceptable.
✗
Question 70. What does an inspector look at when he checks the safety system on board?
Your Answer: (Not answered)
Correct Answer: B (the certificates being valid and the documents in place, then the records set against the ship as she is)
💡 It begins with the certificates: the document of compliance and the pages listing the ship types it covers against this ship, the safety management certificate or its interim issue standing in date and the conditions of its issue having been met. Then whether the documents are actually on board at their current issue, and whether the procedures and instructions match this ship's equipment and cargo. Then the records: what internal audit and management review concluded and what moved after them, training and familiarisation done, the maintenance plan kept or deferred and how the deferral was handled, drills held with their content and what they showed. The three steps are compared - what the system says, what the record shows, what the deck presents - and where the paper is complete but the ship does not answer it, the finding is that the system does not work, not that a page is missing; hence certificates alone, or the signature closing a last year's finding alone, prove nothing.
✗
Question 71. What do SOLAS and the related handbooks emphasise about assembling survival craft after abandonment?
Your Answer: (Not answered)
Correct Answer: A (Craft should stay together where possible, maintaining contact and acting in a coordinated way to aid detection)
💡 SOLAS and survival craft handbooks favour keeping the craft together or close, permitting coordinated action, mutual support and easier detection by rescuers. Scattering is not recommended.
✗
Question 72. What marking shall survival craft have for night detection?
Your Answer: (Not answered)
Correct Answer: D (Lighting or retro-reflective material to aid detection)
💡 Lighting or retro-reflective material to aid detection.
✗
Question 73. What is required when testing DSC or radio equipment in port?
Your Answer: (Not answered)
Correct Answer: A (Test on the prescribed channel or under the prescribed conditions, avoiding a false distress alert and taking precautions before testing)
💡 Testing radio equipment, especially DSC, should be carried out on the prescribed channel or under the prescribed conditions with precautions against transmitting a false distress alert, such as using the specific test setting and avoiding an actual distress alert. A false alert wastes search and rescue resources and may attract a penalty.
✗
Question 74. What preventive measures do SOLAS and the IMO circulars emphasise for accidents during survival craft drills?
Your Answer: (Not answered)
Correct Answer: B (Use tested release gear, ensure familiarity with the procedure and avoid hazardous launch conditions)
💡 Accidents during boat drills commonly arise from defective release gear or mishandling. The IMO circulars require tested gear, strict adherence to the procedure and prudent choice of conditions, not the cancellation of drills.
✗
Question 75. What is the principal characteristic of class 3 dangerous goods?
Your Answer: (Not answered)
Correct Answer: C (Flammable liquids, whose vapour can be ignited at ambient temperature)
💡 Class 3 of the IMDG Code covers flammable liquids, being liquids which give off flammable vapour at or below their flashpoint. Explosives are class 1 and oxidising substances class 5.
✗
Question 76. Which systems shall be used to receive navigational warnings?
Your Answer: (Not answered)
Correct Answer: C (Maritime safety information systems such as NAVTEX and SafetyNET)
💡 Systems such as NAVTEX and SafetyNET.
✗
Question 77. Besides the capacity requirement, what else must be considered for liferafts under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (They must be able to float free if the ship sinks, fitted with a hydrostatic release unit)
💡 SOLAS requires liferafts to float free if the ship sinks, fitted with a hydrostatic release unit and a weak link. Locking them or stowing them in a hold makes them unavailable on abandonment and is a deficiency.
✗
Question 78. What does SOLAS address regarding the combustibility of curtains and decorative materials in accommodation?
Your Answer: (Not answered)
Correct Answer: D (Their combustibility must be restricted, using flame retardant or treated materials)
💡 SOLAS places requirements on the combustibility of curtains, carpets and decorative materials in accommodation spaces, requiring flame retardant or treated materials to prevent fire from spreading rapidly along them.
✗
Question 79. An EPIRB was found with an expired battery. What is the finding?
Your Answer: (Not answered)
Correct Answer: B (A deficiency; the battery must be within its expiry date, as an expired battery affects distress alerting capability)
💡 An expired EPIRB battery means the equipment cannot sustain the prescribed transmission period, normally not less than 48 hours, in a distress. This is a deficiency affecting distress alerting capability, and the battery or the equipment should be replaced at once with the release mechanism checked.
✗
Question 80. What do SOLAS and good practice recommend for the handling of survival craft after abandonment?
Your Answer: (Not answered)
Correct Answer: B (Move clear of the ship as soon as possible, avoiding suction by the sinking ship or being trapped by burning oil)
💡 After abandonment, survival craft should be moved clear of the ship as soon as possible, avoiding the suction of a sinking ship, falling debris or being surrounded by burning oil. Remaining close to the ship greatly increases the danger.
✗
Question 81. What does SOLAS require for manholes and access doors in watertight bulkheads?
Your Answer: (Not answered)
Correct Answer: C (They must be watertight, kept closed and properly secured, and not left permanently open)
💡 SOLAS requires manhole covers and access doors in watertight bulkheads to be watertight and properly secured, kept closed normally. Leaving them open means the ship loses subdivision protection on damage, a serious deficiency.
✗
Question 82. What safety should be noted for personnel during radio transmission?
Your Answer: (Not answered)
Correct Answer: B (Avoid remaining near the antenna, and do not stay close in the direction of radiation)
💡 A transmitting antenna produces radio frequency radiation, so personnel should avoid remaining near it, particularly close and in the direction of radiation, and transmission should be stopped before working on the antenna or equipment. Prolonged close exposure is a health hazard.
✗
Question 83. What should be done after a water ingress alarm on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (Identify the flooded hold, assess the effect on stability and strength and take measures such as pumping or adjustment, reporting as required)
💡 On a water ingress alarm the flooded hold and the cause should be established at once, such as hatch leakage, hull damage or piping leakage, the effect on stability, strength and draught assessed and measures taken such as pumping, adjusting ballast or reducing cargo, with the company and the Administration informed under the SMS.
✗
Question 84. What is required for stability calculation after loading is completed?
Your Answer: (Not answered)
Correct Answer: C (Calculate the stability for the departure and arrival conditions and confirm compliance with the stability information)
💡 SOLAS requires the stability for departure and arrival conditions to be calculated and confirmed against the stability information, checking parameters such as metacentric height and righting levers. Any exceedance requires adjustment.
✗
Question 85. What must the muster list show regarding crew duties under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (The specific duty of each crew member in each type of emergency and the substitutes arranged for key positions)
💡 SOLAS requires the muster list to set out the specific duty of each crew member in emergencies such as abandonment, fire and flooding, with substitutes for key positions arranged, so that the absence of a key person does not leave a task unperformed.
✗
Question 86. What should be done about fire doors that do not close properly?
Your Answer: (Not answered)
Correct Answer: B (Adjust or replace the self-closing device and seals promptly so that they close reliably in a fire)
💡 A fire door that does not close properly, for example because the self-closing device has failed, the frame is distorted or the seal has perished, allows smoke and flame to pass. It should be adjusted or its parts replaced promptly to close reliably in a fire; securing it with rope is not permitted.
✗
Question 87. Which is the 4 MHz band DSC distress frequency among the HF frequencies?
Your Answer: (Not answered)
Correct Answer: A (4207.5 kHz)
💡 HF DSC distress frequencies are 4207.5, 6312, 8414.5, 12577 and 16804.5 kHz. 2187.5 kHz is an MF frequency and 6312 kHz belongs to the 6 MHz band.
✗
Question 88. What communication is required when entering an enclosed space?
Your Answer: (Not answered)
Correct Answer: B (Continuous communication with the standby person, including periodic contact, with immediate withdrawal if it is lost)
💡 SOLAS and the IMO resolutions require the entrant to maintain continuous communication with the standby person at the entrance, normally by agreed periodic contact, and to withdraw at once if communication cannot be restored, preventing an incident from going unnoticed.
✗
Question 89. What performance must survival craft achieve in respect of wind and sea conditions under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (They must float safely and retain their performance under the prescribed wind and sea conditions)
💡 SOLAS requires survival craft designed for the prescribed wind and sea conditions, able to float safely and maintain their essential performance in heavy weather. A declaration for calm water alone does not meet the needs after abandonment.
✗
Question 90. One space uses smoke detectors and another heat detectors. What is the main basis for choosing detector type?
Your Answer: (Not answered)
Correct Answer: A (The type and characteristics of fire likely in the space, such as smoke production or rapid temperature rise)
💡 SOLAS requires the detector type to suit the fire expected in the space: smoke detectors where smoke will be produced, heat detectors where rapid temperature rise without much smoke may occur. The wrong choice delays the alarm.
✗
Question 91. The total capacity of the fire pumps on a cargo ship shall not be less than:
Your Answer: (Not answered)
Correct Answer: C (the required capacity of each pump)
💡 SOLAS II-2/10 requires the total capacity of fire pumps on a cargo ship to be not less than the required capacity of each pump.
✗
Question 92. A ship is to load dangerous goods but lacks the emergency information required. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (Obtain the EmS Guide, MFAG and other emergency information before loading; otherwise refuse to load)
💡 SOLAS VII requires a ship carrying dangerous goods to have the EmS Guide, MFAG and similar emergency information. Without it the master should not agree to load. Loading first and supplying the information afterwards would leave the ship unable to respond effectively to an incident, a breach.
✗
Question 93. What is the basic principle for selecting portable extinguishers for a machinery space?
Your Answer: (Not answered)
Correct Answer: B (the class of fire likely in the space deciding the choice, oil and electrical fires requiring a suitable agent, the number and siting as prescribed)
💡 In a machinery space the likely fires are oil and electrical. Water will spread a burning oil fire and carries the shock risk on live equipment, so it belongs to solid combustible fires; here foam, powder or carbon dioxide suits the class, with the capacity, number and siting the rules call for along passages and in spaces, placed where a hand can reach it and not blocked by gear or cargo. Carbon dioxide released in quantity in a small closed space drives the oxygen down, which has to be thought of as the party withdraws. Counting only the extinguishers and their service dates, without regard to whether the type suits the space, is a deficiency waiting to be written up and a mistake waiting to be made at the fire itself.
✗
Question 94. What stability concern does SOLAS address when a ship encounters deck seas or ice accretion?
Your Answer: (Not answered)
Correct Answer: B (Assess the adverse effect of water on deck and ice accretion on stability and freeboard and take measures)
💡 SOLAS and the Load Line Convention require account to be taken of the added weight of water on deck and ice accretion and their effect on stability and freeboard, with measures such as reducing deck cargo or altering course to reduce risk.
✗
Question 95. What material and structural requirements apply to class A divisions?
Your Answer: (Not answered)
Correct Answer: A (They must be of steel or another approved equivalent material, suitably stiffened to maintain structural integrity)
💡 SOLAS requires class A divisions to be of steel or another approved equivalent material, suitably stiffened so that they retain structural integrity and prevent the passage of smoke and flame after the standard fire test.
✗
Question 96. Who provides ice information services?
Your Answer: (Not answered)
Correct Answer: D (The coastal State authority or designated service)
💡 The coastal State authority or a designated service.
✗
Question 97. What ongoing attention to stability is required during a voyage?
Your Answer: (Not answered)
Correct Answer: D (Attention to the effect on stability of consumption of ballast, fuel and fresh water and of water and ice on deck)
💡 During a voyage the consumption of fuel, fresh water and ballast and the effects of water and ice on deck and moisture taken up by cargo all change stability. Attention should be maintained in accordance with the stability information, adjusting ballast where necessary, preventing stability from becoming insufficient or excessive.
✗
Question 98. A cargo ship has lost all main power and is on the emergency generator. Under SOLAS II-1/42, for how long must emergency lighting be maintained on a cargo ship?
Your Answer: (Not answered)
Correct Answer: B (18 hours)
💡 Emergency lighting must be maintained for 18 hours on cargo ships and 36 hours on passenger ships. Three hours is the minimum duration for the electric safety lamp of a firefighter's outfit — the two figures are easily confused.
✗
Question 99. What protection does SOLAS require for electric and electrohydraulic steering gear?
Your Answer: (Not answered)
Correct Answer: A (Short circuit and overload protection, with an alarm for single phase failure)
💡 SOLAS II-1/30 requires electric and electrohydraulic steering gear to have short circuit and overload protection and to give an alarm in the event of a single phase failure, preventing sudden loss of steering.
✗
Question 100. What checking of survival craft markings is required?
Your Answer: (Not answered)
Correct Answer: A (Confirm the ship's name, port of registry and number of persons the craft can accommodate are clearly and completely marked)
💡 SOLAS requires survival craft to be clearly marked with the ship's name, port of registry and the number of persons it can accommodate. Inspection should confirm the markings are clear, durable and complete. Illegible markings hamper identification of the ship by rescuers and judgement of the craft's capacity, and are a common deficiency.