Question 1. Which system, directly related to fire protection, is required in accommodation and service spaces?
Your Answer:
(Not answered) Correct Answer:
B (Fixed fire detection and alarm system)
💡 SOLAS II-2/12 requires fixed fire detection and alarm systems in accommodation and service spaces.
✗
Question 2. Before loading, the ship shall ensure that:
Your Answer:
(Not answered) Correct Answer:
A (cargo is properly stowed and secured so as not to endanger the ship)
💡 SOLAS VI/2 requires cargo to be properly stowed and secured to avoid endangering the ship.
✗
Question 3. A ship is found without the manoeuvrability information for its type and trading area, such as the wheelhouse poster and manoeuvring booklet. The finding is?
Your Answer:
(Not answered) Correct Answer:
B (Manoeuvrability information should be provided for the navigators; absence is a deficiency to be corrected)
💡 A ship should carry the required manoeuvrability information, such as the manoeuvring booklet and the wheelhouse poster, so that the navigators know the turning, stopping and course-keeping characteristics of the vessel. Absence affects decisions in narrow channels, berthing and emergency manoeuvring. It is a deficiency to be corrected.
✗
Question 4. What does SOLAS address regarding action if the inert gas system fails?
Your Answer:
(Not answered) Correct Answer:
C (Stop the relevant operations immediately and notify the terminal and take emergency measures)
💡 SOLAS and industry guidance require the relevant operations to stop at once if the inert gas system fails, with the terminal informed and emergency measures taken, preventing explosion from carrying on operations with inerting lost.
✗
Question 5. How often must inflatable liferafts be serviced under SOLAS?
Your Answer:
(Not answered) Correct Answer:
B (At intervals not exceeding 12 months at an approved servicing station)
💡 SOLAS requires inflatable liferafts to be serviced at intervals not exceeding 12 months at an approved servicing station, while rigid lifeboats are subject to the prescribed annual inspection. The crew cannot replace the approved servicing.
✗
Question 6. What does SOLAS require regarding the starting arrangements for fire pumps?
Your Answer:
(Not answered) Correct Answer:
C (They must be capable of remote starting from the bridge or fire control station, with means at the hydrants to start a pump)
💡 SOLAS requires fire pumps to be capable of remote starting by the watchkeeper from the bridge or a fire control station, with means at the hydrants to start a pump, so water is available quickly in a fire.
✗
Question 7. A crew member is found serving in a position with an expired certificate of competency. The finding is?
Your Answer:
(Not answered) Correct Answer:
A (Serving without a valid certificate is a serious violation that may lead to detention)
💡 A crew member should hold a valid certificate of competency for the rank and the required training certificates. Serving with an expired certificate violates the safe manning and certification rules and is a serious deficiency, normally detainable, which requires renewal or a change of personnel before departure.
✗
Question 8. What is the minimum daily water ration per person in a survival craft under SOLAS III/7.1?
Your Answer:
(Not answered) Correct Answer:
A (1.5 litres)
💡 SOLAS III/7.1 requires not less than 1.5 litres of water per person per day in survival craft, for the required number of days at the rated capacity. One litre is a common misremembering.
✗
Question 9. What does the IMSBC Code require when loading high density cargo into a bulk carrier?
Your Answer:
(Not answered) Correct Answer:
C (Control of the weight in each hold, the sequence of loading and the differences between adjacent holds, avoiding excessive local stress and deformation)
💡 The IMSBC Code and SOLAS require strict control of the weight in each hold, the sequence and the differences between adjacent holds when loading high density cargo, preventing excessive local stress on the tank top and hull, which could cause permanent deformation or failure.
✗
Question 10. What safety is required in operating ballast system valves?
Your Answer:
(Not answered) Correct Answer:
B (Valves clearly identified and operated in order, preventing misoperation causing cross-connection or cargo contamination)
💡 SOLAS and good practice require the valves of the ballast and bilge systems to be clearly identified and operated in a proper sequence, normally following the ballast plan, preventing an inadvertent opening from cross-connecting ballast and cargo tanks, contaminating cargo or causing a sudden change in stability.
✗
Question 11. What certificate must a ship operating in polar waters carry?
Your Answer:
(Not answered) Correct Answer:
C (A Polar Ship Certificate)
💡 SOLAS XIV/3 requires ships operating in polar waters to hold a Polar Ship Certificate attesting compliance with the relevant parts of the Polar Code.
✗
Question 12. What must be satisfied before dangerous goods packages are loaded on board?
Your Answer:
(Not answered) Correct Answer:
C (Packages must be of a tested and certified type, in good condition, and correctly marked and labelled)
💡 SOLAS VII and the IMDG Code require packages of a tested type in good condition, correctly marked with the proper shipping name, UN number and hazard labels. All elements are required.
✗
Question 13. What is the master's responsibility under SOLAS V?
Your Answer:
(Not answered) Correct Answer:
A (Ultimate responsibility for the safety of the ship and persons, which may not be assumed by others)
💡 The master bears ultimate responsibility for the safety of the ship and those on board.
✗
Question 14. Safety practice for the carriage of solid bulk cargoes shall follow:
Your Answer:
(Not answered) Correct Answer:
A (the IMSBC Code)
💡 SOLAS VI/6: the carriage of solid bulk cargoes shall follow the IMSBC Code.
✗
Question 15. On finding a deficiency in the safety management system, what must the master do under the ISM Code?
Your Answer:
(Not answered) Correct Answer:
C (Report the deficiency to the shore management and suggest improvements)
💡 ISM Code 5.1.5 requires the master to review the SMS and report deficiencies to the shore-based management with proposals for improvement. He may neither amend the system himself nor merely record the matter in the log.
✗
Question 16. A Cargo Securing Manual:
Your Answer:
(Not answered) Correct Answer:
D (shall be provided, giving details of securing devices and requirements)
💡 SOLAS VI/5: a Cargo Securing Manual giving details of securing devices and requirements shall be provided.
✗
Question 17. What is the maximum length of a fire hose for use on the open deck?
Your Answer:
(Not answered) Correct Answer:
B (20 m)
💡 On the open deck and in accommodation spaces the hose shall not exceed 20 m.
✗
Question 18. Why does SOLAS require firefighter's outfits to be stowed in more than one location?
Your Answer:
(Not answered) Correct Answer:
A (To prevent a fire in one place from making all the outfits unavailable, so they are distributed)
💡 SOLAS requires firefighter's outfits to be stowed in two or more positions because, if they were all in one place, a fire there would make every outfit unavailable and firefighting and rescue could not proceed.
✗
Question 19. What must the line-throwing appliance achieve under SOLAS?
Your Answer:
(Not answered) Correct Answer:
C (Throw a line not less than 230 m, with not fewer than four lines and four projectiles)
💡 SOLAS III/18 requires the line-throwing appliance to throw a line not less than 230 m, provided with four lines and four projectiles, for establishing contact with a casualty or the shore. Insufficient range or quantity reduces the rescue capability.
✗
Question 20. A cargo ship shall be provided with at least how many rescue boats?
Your Answer:
(Not answered) Correct Answer:
D (1)
💡 SOLAS III/31 requires cargo ships to be provided with at least one rescue boat.
✗
Question 21. Which describes the periodical survey under SOLAS?
Your Answer:
(Not answered) Correct Answer:
D (Carried out periodically and may replace an annual survey)
💡 The periodical survey may replace one of the annual surveys.
✗
Question 22. What crew preparation is required before entering ice in polar waters?
Your Answer:
(Not answered) Correct Answer:
D (Special polar operations training, clear emergency duties for ice conditions and drills of emergency procedures at low temperature)
💡 The Polar Code requires relevant training and familiarisation before entering polar waters, covering the contents of the PWOM, ice operating procedures and the use of emergency and life-saving equipment in low temperature, with the duties of each position in an ice emergency made clear and corresponding drills held.
✗
Question 23. What does SOLAS address regarding the axe in a firefighter's outfit?
Your Answer:
(Not answered) Correct Answer:
D (An axe suitable for breaking through must be provided and stowed with the rest of the outfit)
💡 SOLAS requires an axe to be provided in the firefighter's outfit for breaking through doors, windows and structure in smoke-filled or obstructed conditions, stowed with the rest of the outfit in an accessible position.
✗
Question 24. What is the safety significance of spare parts management?
Your Answer:
(Not answered) Correct Answer:
D (Essential parts must be carried for critical equipment so that failures can be repaired promptly without affecting safety)
💡 Carrying spares for critical safety equipment, such as parts for fire pumps, wearing components of the emergency generator and steering gear and items of life-saving equipment, enables failures to be repaired promptly, avoiding the ship remaining in a deficient state for a long time while spares are awaited, which would affect her safety.
✗
Question 25. What should be noted about the combined operation of watertight doors and the bilge system?
Your Answer:
(Not answered) Correct Answer:
B (The interaction of door closure with bilge pumping should be considered, avoiding a change in heel or stability from pumping or flooding)
💡 Bilge pumping and ballast operations change the distribution of weight and the heel of the ship. They should be considered together with the open or closed state of the watertight doors, preventing pumping or flooding from increasing the list, altering stability or cross-connecting compartments, particularly when the ship is already damaged.
✗
Question 26. The VDR is found not to have recorded the bridge audio and radar images of the recent voyage. The finding is?
Your Answer:
(Not answered) Correct Answer:
C (The VDR must continuously record the required data; failure to record affects accident investigation)
💡 The VDR is used to reconstruct the navigation and decisions at the time of an accident and should continuously record the required data, such as position, speed, radar images, bridge audio and alarms. Failure to record key data deprives an accident investigation of its basis. It is a deficiency to be corrected.
✗
Question 27. What does SOLAS address regarding the equilibrium condition in damage stability calculations?
Your Answer:
(Not answered) Correct Answer:
B (After flooding the ship must satisfy the residual stability criteria in the equilibrium condition)
💡 SOLAS requires that, once the ship reaches equilibrium after flooding, taking account of the water entered and the resulting heel, the residual stability curve satisfies the prescribed criteria such as the range of righting levers and the maximum righting lever. Intact stability criteria alone are not a substitute.
✗
Question 28. What is the purpose of a loading instrument on a bulk carrier?
Your Answer:
(Not answered) Correct Answer:
A (Computing hull strength and stability at each stage of loading)
💡 Computing hull strength and stability at each stage of loading and discharging.
✗
Question 29. Where must the closing devices of main machinery space ventilation openings be operable?
Your Answer:
(Not answered) Correct Answer:
A (From a readily accessible position outside the machinery space, clearly marked)
💡 SOLAS requires the closing devices of the main inlets and outlets of machinery space ventilation to be operable from a readily accessible position outside the machinery space, clearly marked, so that ventilation can be shut off in a fire without entering the space.
✗
Question 30. A ship is to load dangerous goods but lacks the emergency information required. What does SOLAS require?
Your Answer:
(Not answered) Correct Answer:
B (Obtain the EmS Guide, MFAG and other emergency information before loading; otherwise refuse to load)
💡 SOLAS VII requires a ship carrying dangerous goods to have the EmS Guide, MFAG and similar emergency information. Without it the master should not agree to load. Loading first and supplying the information afterwards would leave the ship unable to respond effectively to an incident, a breach.
✗
Question 31. What is required for escape routes in an emergency?
Your Answer:
(Not answered) Correct Answer:
C (They must be usable in fire and smoke, with low level lighting, kept clear and doors openable from inside without a key)
💡 SOLAS requires escape routes to be designed and arranged to remain usable in a fire, with low level lighting enabling the direction to be seen in dense smoke, the route kept clear and doors openable from inside without a key, so that personnel can evacuate safely.
✗
Question 32. Navigation publications required under SOLAS include:
Your Answer:
(Not answered) Correct Answer:
C (charts, sailing directions and notices to mariners)
💡 SOLAS V/27 requires adequate charts, nautical publications and notices to mariners.
✗
Question 33. What do SOLAS V and COLREG require when navigating in a narrow channel?
Your Answer:
(Not answered) Correct Answer:
A (Keep as near to the outer limit on the starboard side as is safe and practicable, at a safe speed with an adequate look-out)
💡 COLREG Rule 9 requires a vessel in a narrow channel to keep as near to the outer limit on her starboard side as is safe and practicable, at a safe speed with an adequate look-out. High speed or occupying any part of the channel greatly increases the risk of collision.
✗
Question 34. What does SOLAS require of the water ingress detection and alarm system on a bulk carrier?
Your Answer:
(Not answered) Correct Answer:
B (Detection in cargo holds, ballast tanks and dry spaces, with an audible and visual alarm on the bridge)
💡 SOLAS XII/12 requires a bulk carrier to have water ingress detection in cargo holds, ballast tanks and dry spaces, with an audible and visual alarm on the bridge, enabling the watchkeeper to detect flooding promptly and act.
✗
Question 35. Besides rocket parachute flares and hand flares, which other pyrotechnic is required among the lifeboat's distress signals?
Your Answer:
(Not answered) Correct Answer:
A (Buoyant smoke signals)
💡 SOLAS III/7.2 requires the lifeboat to carry distress signals comprising rocket parachute flares, hand flares and buoyant smoke signals. Extinguishers and first aid kits are separate items of equipment.
✗
Question 36. Under what conditions shall the windlass reliably hold the anchor?
Your Answer:
(Not answered) Correct Answer:
B (Under the specified weather conditions)
💡 It shall be capable of holding the anchor under the specified conditions.
✗
Question 37. An inert gas system shall be used:
Your Answer:
(Not answered) Correct Answer:
A (to maintain cargo tanks inert during cargo operations, ballasting and while at sea)
💡 SOLAS II-2/5: the inert gas system shall be used to maintain cargo tanks inert during cargo operations, ballasting and while at sea.
✗
Question 38. Which means of look-out meets SOLAS requirements?
Your Answer:
(Not answered) Correct Answer:
A (Sight, hearing and all available means appropriate to the circumstances)
💡 Sight, hearing and all available means appropriate to the circumstances.
✗
Question 39. For a cargo ship of 100 m and above, the number of lifebuoys with self-igniting lights shall be not less than:
Your Answer:
(Not answered) Correct Answer:
B (8)
💡 SOLAS III/32 requires not less than eight lifebuoys with self-igniting lights for cargo ships of 100 m and above.
✗
Question 40. How shall cargo units be loaded and secured?
Your Answer:
(Not answered) Correct Answer:
B (So as to withstand the forces expected during the voyage without shifting)
💡 So as to withstand expected forces without shifting.
✗
Question 41. What does a B-15 class division mean?
Your Answer:
(Not answered) Correct Answer:
D (It prevents the passage of flame and limits temperature rise for 15 minutes in the standard fire test)
💡 Class B divisions are graded B-15 and B-0, the figure being the period in minutes for which temperature rise is limited in the standard fire test. Class B divisions are of non-combustible material, preventing passage of flame with lower strength than class A.
✗
Question 42. What closed-loop management of hazards is required?
Your Answer:
(Not answered) Correct Answer:
B (Assign responsibility, measures and deadlines for each hazard found and track it to closure, with reasons recorded for items not completed)
💡 Hazards found at inspections, drills, reports and internal audits should be managed in a closed loop: assigning the person responsible and a deadline, implementing the measures, verifying the effect, closing the item and recording it. Items not completed on time should have the reason stated, the risk assessed and a new arrangement made, preventing hazards from persisting.
✗
Question 43. What does SOLAS address regarding redundancy and reliability of propulsion machinery?
Your Answer:
(Not answered) Correct Answer:
A (Stand-by or alternative means for critical auxiliary equipment, preventing loss of propulsion from a single failure)
💡 SOLAS requires stand-by or alternative means for critical auxiliaries affecting propulsion, such as cooling water pumps, lubricating oil pumps and fuel pumps, preventing loss of propulsion from a single failure, which would have serious consequences especially in confined waters.
✗
Question 44. What is the requirement for rescue boats on cargo ships?
Your Answer:
(Not answered) Correct Answer:
D (At least one rescue boat)
💡 At least one rescue boat shall be provided.
✗
Question 45. Subdivision of a passenger ship is based on which load line?
Your Answer:
(Not answered) Correct Answer:
A (Subdivision load line)
💡 It is based on the subdivision load line.
✗
Question 46. A pressure test found insufficient pressure when two jets were played simultaneously. What does SOLAS require?
Your Answer:
(Not answered) Correct Answer:
A (Fire pumps must maintain the prescribed pressure and jets when the required number of hydrants are in simultaneous use)
💡 SOLAS II-2 requires the fire pumps to maintain the prescribed pressure and reach of the jets with the required number of hydrants in simultaneous use. Insufficient pressure impairs firefighting and is a deficiency.
✗
Question 47. If a conversion reduces the lifeboats from two per side to one, what does SOLAS require?
Your Answer:
(Not answered) Correct Answer:
B (Assessment and approval by the Administration or classification society beforehand, confirming the capacity requirement is still met)
💡 SOLAS requires changes to the life-saving appliance arrangement to be assessed and approved by the Administration or the classification society, confirming that the requirements for capacity per side, rescue boat and equipment are still met. Reducing the lifeboats without authority means the ship cannot ensure all persons can escape if one side is lost.
✗
Question 48. What are the common risks in launching and recovering survival craft?
Your Answer:
(Not answered) Correct Answer:
A (Inadvertent operation of the release gear dropping the boat and injuring persons, and persons being crushed between the falls and the boat)
💡 The principal risks in launching and recovering a lifeboat include the release gear operating inadvertently and dropping the boat, persons being crushed between the falls and the boat and the boat striking the ship's side. Procedures should be strictly followed, coordination maintained and positions chosen with care.
✗
Question 49. What launching methods are acceptable for survival craft?
Your Answer:
(Not answered) Correct Answer:
C (Davit, free-fall or others appropriate to the type, all ensuring safety)
💡 Methods appropriate to the type, such as davit or free-fall, are acceptable.
✗
Question 50. What do SOLAS and the IMDG Code require during loading and unloading of dangerous goods?
Your Answer:
(Not answered) Correct Answer:
D (Fire prevention, spill prevention and personal protection measures, with working conditions controlled according to the cargo)
💡 SOLAS VII and the IMDG Code require fire and explosion prevention, spill prevention, personal protection and emergency preparedness during cargo work, with hold conditions such as temperature and ventilation controlled according to the cargo and the port informed and signs displayed as necessary.
✗
Question 51. What is required for checking the pressure of firefighter's breathing apparatus cylinders?
Your Answer:
(Not answered) Correct Answer:
A (Periodic checks of cylinder pressure and tightness, with refilling or replacement when pressure is low)
💡 Breathing apparatus cylinders should be checked periodically for pressure, normally not less than 80 to 90 per cent of the rated pressure, and for tightness, with refilling or replacement when low or expired. Running short of air inside a fire is fatal.
✗
Question 52. Ships shall carry for distress communication:
Your Answer:
(Not answered) Correct Answer:
A (radio personnel holding appropriate certificates, or watch officers with the required certificate)
💡 SOLAS IV/16 requires ships to carry radio personnel holding appropriate certificates for distress and safety communication.
✗
Question 53. Under the ISM Code, the company shall designate person(s) (DPA) to be responsible for:
Your Answer:
(Not answered) Correct Answer:
C (linking the company with the ship on safety and pollution prevention matters)
💡 SOLAS IX/6: the company shall designate person(s) (DPA) to link the company with the ship on safety and pollution prevention matters.
✗
Question 54. What does SOLAS require when the steering gear or another critical item of equipment fails at sea?
Your Answer:
(Not answered) Correct Answer:
B (Notify the master immediately, take emergency action, record the failure and report to the Administration where required)
💡 SOLAS and STCW require immediate notification of the master and emergency action on failure of critical equipment, with the failure recorded and reported to the Administration or port State where necessary. Concealment may itself be a serious deficiency.
✗
Question 55. The emergency fire pump needs manual priming before it will draw water. What does SOLAS address?
Your Answer:
(Not answered) Correct Answer:
B (A deficiency; the emergency fire pump must draw water by itself, and manual priming would delay emergency use)
💡 SOLAS requires the emergency fire pump to be self-priming, or to have a priming arrangement meeting the requirements, so that it draws water without manual priming in an emergency. Needing manual priming would delay the water supply when it matters and is a deficiency.
✗
Question 56. What does the Polar Code require regarding life-saving appliances in polar waters?
Your Answer:
(Not answered) Correct Answer:
C (They must work at low temperature, with measures to extend survival time in the polar environment)
💡 The Polar Code requires life-saving appliances to function at low temperature and for measures to extend survival time, such as additional thermal protection, collective survival equipment and search aids.
✗
Question 57. While underway the ship receives word from her Administration that the security level has been raised, while the terminal remains at the former level. What applies on board?
Your Answer:
(Not answered) Correct Answer:
A (the notified level being implemented with the master's instructions, co-ordinated with the port facility security officer, the facility's own level not reducing the ship's duty)
💡 Levels are set for the ship by her Administration and for the facility by the Contracting Government; on notice of an increase the ship implements the additional measures of her plan for that level, informs the master, crew and the facility concerned, and settles any mismatch by co-ordination. The terminal staying at the lower level does not reduce the ship's duty, and relaxing the ship to match it is not the answer.
✗
Question 58. An EPIRB was found with an expired battery. What is the finding?
Your Answer:
(Not answered) Correct Answer:
B (A deficiency; the battery must be within its expiry date, as an expired battery affects distress alerting capability)
💡 An expired EPIRB battery means the equipment cannot sustain the prescribed transmission period, normally not less than 48 hours, in a distress. This is a deficiency affecting distress alerting capability, and the battery or the equipment should be replaced at once with the release mechanism checked.
✗
Question 59. Should satellite positioning fail, the vessel relies on which alternative means?
Your Answer:
(Not answered) Correct Answer:
A (Compass bearings together with chart observation)
💡 Traditional observation with compasses and charts remains the fall-back means.
✗
Question 60. What cleanliness and dryness is required of holds before loading a bulk carrier?
Your Answer:
(Not answered) Correct Answer:
B (Holds to be clean, dry and free of residues from the previous cargo, preventing contamination and chemical reaction)
💡 Before loading a bulk carrier the holds should be confirmed clean, dry and free of smell and residues from the previous cargo, such as rust, oil and chemical traces, preventing contamination or reaction with residues producing harmful gas and self-heating. There should be no standing water or refuse.
✗
Question 61. What is the stability concern when carrying grain in bulk?
Your Answer:
(Not answered) Correct Answer:
B (Heeling moments from grain settling and shifting cause a list, assessed under the International Grain Code)
💡 Grain in bulk settles and shifts as the ship rolls, producing heeling moments and a persistent list. The International Grain Code requires stability to be assessed using assumed heeling moments from grain shift, with the resulting angle of heel limited to a prescribed value, normally 12 degrees.
✗
Question 62. With regard to bridge visibility, SOLAS requires that:
Your Answer:
(Not answered) Correct Answer:
B (a clear view of the sea surface forward shall be available from the conning position, not obstructed by cargo or structure)
💡 SOLAS V/22 requires a clear forward view from the conning position, unobstructed by cargo or structure.
✗
Question 63. What is the main use of radar in restricted visibility?
Your Answer:
(Not answered) Correct Answer:
D (Assisting in assessing the risk of collision)
💡 To assist in assessing the risk of collision, not to replace the look-out.
✗
Question 64. The quantity of extinguishing medium stored for a fixed gas fire-extinguishing system shall be sufficient for:
Your Answer:
(Not answered) Correct Answer:
B (the volume of the largest protected space)
💡 SOLAS II-2/10 requires the stored quantity of medium to be sufficient for the largest protected space.
✗
Question 65. The ropes' breaking strength exceeds that of the equipment. Why is this entered as a deficiency?
Your Answer:
(Not answered) Correct Answer:
C (mooring gear is designed to a safe working load; a rope far above it breaks the bollard or winch first, and a parted rope whips back through the people standing in it)
💡 Information on the safe working load of the mooring and towing equipment must be held on board, and the breaking strength of the ropes put to use has to match what the gear can take. It is the gear that the rope's force destroys: the stronger the rope, the greater the force reaching the bollard, winch and their foundations, and if a load-bearing part fails first the parted rope whips across the ground where people stand. A works certificate and the master's experience replace nothing of this matching, and the record of which rope goes with which fitting must survive.
✗
Question 66. From what tonnage shall speed and distance measuring equipment be fitted?
Your Answer:
(Not answered) Correct Answer:
B (500 GT)
💡 500 GT and above.
✗
Question 67. When a fire breaks out, which sequence of actions should be completed first under the muster list?
Your Answer:
(Not answered) Correct Answer:
C (Raise the fire alarm, report to the bridge, muster as per the list and begin locating the fire and initial firefighting)
💡 On discovering a fire the alarm should first be raised and the bridge informed, then personnel mustered as per the muster list, the seat and extent of the fire located, initial firefighting begun with escape routes assured and ventilation closed. Raising the alarm has priority in all procedures and cannot follow mustering or informing the company.
✗
Question 68. What should be done about fire doors that do not close properly?
Your Answer:
(Not answered) Correct Answer:
B (Adjust or replace the self-closing device and seals promptly so that they close reliably in a fire)
💡 A fire door that does not close properly, for example because the self-closing device has failed, the frame is distorted or the seal has perished, allows smoke and flame to pass. It should be adjusted or its parts replaced promptly to close reliably in a fire; securing it with rope is not permitted.
✗
Question 69. Fire hoses shall be provided:
Your Answer:
(Not answered) Correct Answer:
B (for each hydrant in sufficient number, including spare hoses)
💡 SOLAS II-2/10: fire hoses shall be provided for each hydrant in sufficient number, including spare hoses.
✗
Question 70. Which Code governs the carriage of dangerous goods in packaged form by sea?
Your Answer:
(Not answered) Correct Answer:
C (IMDG Code)
💡 SOLAS VII/1: the IMDG Code applies to dangerous goods carried in packaged form.
✗
Question 71. What does SOLAS V require when a ship enters a deep-water route?
Your Answer:
(Not answered) Correct Answer:
A (To report to the appropriate authority as required and comply with the conditions of use)
💡 SOLAS V requires ships using deep-water routes to report as prescribed and comply with conditions such as under-keel clearance, so as to reduce the risk of grounding.
✗
Question 72. For a cargo ship of 2000 GT and above, the auxiliary steering gear shall put the rudder over how quickly?
Your Answer:
(Not answered) Correct Answer:
C (From 15° one side to 15° the other in not more than 30 seconds)
💡 SOLAS II-1/29: the auxiliary steering gear shall be capable of putting the rudder over in 30 seconds.
✗
Question 73. What does SOLAS address regarding level measurement and alarms for fuel and lubricating oil tanks?
Your Answer:
(Not answered) Correct Answer:
B (Level measuring arrangements, with high level alarms where overflow is possible, preventing spillage)
💡 SOLAS requires fuel and lubricating oil tanks to be provided with level measuring arrangements and, where overflow is possible, high level alarms, preventing spillage during bunkering or transfer which would create a fire hazard and pollution.
✗
Question 74. What does an automatic tracking aid do?
Your Answer:
(Not answered) Correct Answer:
D (Track targets automatically and assist in assessing collision risk)
💡 It tracks targets and assists in assessing the risk of collision.
✗
Question 75. What do SOLAS and the related standards require for the cylinders of a fixed CO2 system?
Your Answer:
(Not answered) Correct Answer:
D (Periodic checks of cylinder pressure and weight and verification that the piping is clear)
💡 SOLAS and the related standards require periodic checks of cylinder pressure and weight to detect leakage, and verification that piping and nozzles are clear. A visual check alone will not reveal internal leakage or blockage.
✗
Question 76. What does SOLAS address regarding the relationship between the rated capacity of survival craft and the persons on board?
Your Answer:
(Not answered) Correct Answer:
C (The total rated capacity must meet the needs of all persons on board, with the prescribed margin)
💡 SOLAS requires the total rated capacity of the survival craft, under the rules for each side or the whole ship, to accommodate all persons on board with the prescribed margin. Insufficient capacity would leave some persons with nowhere to go on abandonment, a serious deficiency.
✗
Question 77. Which of the following are common types of fixed fire detection systems?
Your Answer:
(Not answered) Correct Answer:
A (Smoke, heat and flame (radiation) detectors)
💡 SOLAS recognises fixed detection systems including smoke, heat and flame (radiation) types, selected according to the nature of the space and the fire characteristics expected.
✗
Question 78. When a lifeboat also serves as a rescue boat, what conditions must it satisfy under SOLAS?
Your Answer:
(Not answered) Correct Answer:
D (It must meet the requirements for a rescue boat in respect of rapid launching and recovery, speed and manoeuvrability)
💡 SOLAS requires a lifeboat serving as a rescue boat to meet all the rescue boat requirements for rapid launching and recovery, minimum speed and manoeuvrability. Labelling or adding equipment alone is not sufficient.
✗
Question 79. For internal combustion engines in machinery spaces, which requirement of the fuel system shall be met?
Your Answer:
(Not answered) Correct Answer:
A (high-pressure fuel pipes shall be protected to prevent fuel spraying)
💡 SOLAS II-2/4 requires high-pressure fuel pipes to be protected to prevent spray of fuel onto hot surfaces or ignition.
✗
Question 80. How must new regulations and circulars be implemented?
Your Answer:
(Not answered) Correct Answer:
D (Obtain and assess their effect on the ship promptly, implement the measures and train the crew)
💡 The ISM system requires the ship to obtain new regulations, flag State notices and company circulars promptly, assess their actual effect on the ship, covering equipment, procedures, training and records, implement the necessary measures and brief and train the crew, keeping the ship in compliance with the latest requirements.
✗
Question 81. Emergency lighting was tested and some survival craft embarkation stations had no lighting. What does SOLAS require?
Your Answer:
(Not answered) Correct Answer:
C (Embarkation stations, survival craft stowage positions and the water alongside must be lit from the emergency source)
💡 SOLAS requires embarkation stations, survival craft stowage positions and the water alongside to be illuminated from the emergency source of power, ensuring safe abandonment. Torches are not a substitute for fixed emergency lighting.
✗
Question 82. A door in an escape route is found locked. What should be done?
Your Answer:
(Not answered) Correct Answer:
C (Unlock it at once; doors in escape routes must be openable from inside without a key)
💡 A locked door in an escape route prevents evacuation in an emergency. SOLAS requires such doors to be openable from inside without a key. Security concerns should be met by other means such as an alarm, not by obstructing escape.
✗
Question 83. What is the role of the voyage data recorder in casualty investigation?
Your Answer:
(Not answered) Correct Answer:
B (Providing data such as position, course and speed, radar images and bridge audio for investigation)
💡 SOLAS requires the VDR to record navigational and operational data including position, course and speed, radar images, bridge audio and alarms, providing objective evidence for investigation. The data is protected and must not be used at will.
✗
Question 84. What does the ISM Code address regarding evaluation of the effectiveness of the safety management system?
Your Answer:
(Not answered) Correct Answer:
D (Evaluating whether the elements of the system are effectively implemented, through audits and reviews, and identifying opportunities for improvement)
💡 ISM Code 3 requires the company to evaluate the effectiveness of the elements of the safety management system through internal and external audits and management review, identifying problems and opportunities for improvement and taking action, keeping the system suitable and effective.
✗
Question 85. What fire protection is required in the cargo area of a gas carrier?
Your Answer:
(Not answered) Correct Answer:
A (Gas detection and alarm, intrinsically safe or explosion-protected electrical equipment and safety devices protecting the cargo containment system)
💡 SOLAS and the IGC Code require the cargo area of a gas carrier to have flammable gas detection and alarm, intrinsically safe or explosion-protected electrical equipment and devices protecting the pressure and temperature of the cargo containment system, preventing accumulation of leaks and overpressure.
✗
Question 86. What do SOLAS and good practice address regarding the use of watertight doors to control heel after damage?
Your Answer:
(Not answered) Correct Answer:
D (Act in accordance with the damage control information by isolating flooded compartments and, if necessary, counter-flooding to control heel)
💡 SOLAS requires action in accordance with the damage control information and booklet: isolating flooded compartments by closing watertight doors and valves, counter-flooding where necessary to reduce heel and assessing residual stability. Blind action may make the situation worse.
✗
Question 87. To which tankers does the emergency towing arrangement requirement of SOLAS II-1/3-3 apply?
Your Answer:
(Not answered) Correct Answer:
D (Oil tankers of 20000 tonnes deadweight and above)
💡 SOLAS II-1/3-3 requires oil tankers of 20000 tonnes deadweight and above to be fitted with an emergency towing arrangement at bow and stern, so that a disabled tanker can be taken in tow. It is not limited to new ships.
✗
Question 88. What is the minimum number of two-way VHF radiotelephone sets for a cargo ship?
Your Answer:
(Not answered) Correct Answer:
A (Three, with at least one on each side)
💡 Under SOLAS IV/7 a cargo ship should carry at least three two-way VHF radiotelephone sets, with at least one on each side and the remainder stowed such as on the bridge, so that they can be taken into the respective survival craft for on-scene communication during abandonment.
✗
Question 89. What is required for backup power of the firefighting system?
Your Answer:
(Not answered) Correct Answer:
C (The emergency fire pump must have a source of power independent of the main fire pumps, so water is available on a blackout or machinery space fire)
💡 SOLAS requires the emergency fire pump to be independently driven, such as by a dedicated diesel engine or an independent power supply, so that it can still supply water if a blackout or a fire in the machinery space puts the main fire pumps out of action. It is essential to the redundancy of the firefighting system.
✗
Question 90. A watertight door is found unable to be closed remotely from the bridge. The finding is?
Your Answer:
(Not answered) Correct Answer:
A (Watertight doors must be remotely closable with indication of their open or closed position; failure affects subdivision integrity)
💡 Where subdivision requires it a watertight door, especially a remotely controlled one, must be capable of remote closure from the central control station on the bridge with position indication there. Loss of remote control affects the ability to close doors rapidly and maintain subdivision integrity in the event of flooding. It is a deficiency to be corrected.
✗
Question 91. What is required for the batteries of two-way VHF radiotelephones in survival craft?
Your Answer:
(Not answered) Correct Answer:
D (Capacity meeting the required operating time, with periodic testing and replacement)
💡 SOLAS requires the batteries of two-way VHF sets to have capacity for the prescribed operating time, with periodic testing and replacement. Neglecting this means the equipment may not work on abandonment.
✗
Question 92. What is sea area A2?
Your Answer:
(Not answered) Correct Answer:
D (An area within MF coast station coverage, excluding A1)
💡 Within MF coast station coverage with DSC, excluding A1.
✗
Question 93. If a fire drill cannot be held in a month due to bad weather, what does SOLAS require?
Your Answer:
(Not answered) Correct Answer:
A (Hold it as soon as conditions permit and record the reason in the deck log)
💡 SOLAS requires a drill not held in the scheduled month to be held as soon as conditions permit, normally within 24 hours afterwards, with the reason for the delay recorded in the deck log.
✗
Question 94. What protection is required for personnel handling chemicals and oils?
Your Answer:
(Not answered) Correct Answer:
C (Appropriate personal protective equipment provided and correctly used, with prompt washing after contact and health surveillance where necessary)
💡 Personnel handling chemicals, oils or paints should be provided with and correctly use personal protective equipment as the safety data sheets require, including eye and face protection, gloves, protective clothing and respiratory protection, washing promptly after contact, with health surveillance and records where exposure is prolonged or symptoms appear.
✗
Question 95. What is required when comparing radar and AIS targets?
Your Answer:
(Not answered) Correct Answer:
D (Compare the targets shown and establish the cause of any inconsistency, such as incorrect AIS data or radar shadowing)
💡 Where radar and AIS show different targets, such as an AIS target with no radar echo or a large positional difference, the cause should be established: an AIS data entry error, a target without AIS, radar shadowing or a false echo. Verifying promptly avoids a wrong appreciation.
✗
Question 96. What does SOLAS address regarding zoning of fire detection systems?
Your Answer:
(Not answered) Correct Answer:
C (The system must identify the section in which the alarm originated, enabling the fire to be located quickly)
💡 SOLAS requires fixed fire detection systems to be arranged in sections so that the alarm indicates the section or space in which it originated, enabling the watchkeeper to confirm the actual location and act quickly.
✗
Question 97. What does SOLAS address regarding electrical equipment in a paint locker?
Your Answer:
(Not answered) Correct Answer:
C (Explosion-protected equipment or no electrical equipment within the space)
💡 SOLAS requires explosion-protected equipment in a paint locker, or no electrical equipment inside it, such as lighting fitted outside, preventing an electrical spark from igniting paint vapour.
✗
Question 98. Which measure complies with SOLAS for protection against electric shock?
Your Answer:
(Not answered) Correct Answer:
C (Live parts shall be protected against accidental contact)
💡 Live parts which may be accidentally touched shall be protected.
✗
Question 99. What navigational measures should the officer of the watch take in restricted visibility?
Your Answer:
(Not answered) Correct Answer:
D (Engines ready for immediate manoeuvre, enhanced look-out and radar observation, reducing speed as required and using sound signals)
💡 COLREG Rule 19 and good seamanship require engines ready for immediate manoeuvre, an enhanced look-out and radar observation, reduction of speed or stopping where necessary and the prescribed sound signals, so that other vessels are warned in due time.
✗
Question 100. What is the principal risk addressed by the requirements for venting arrangements of tanker cargo tanks?
Your Answer:
(Not answered) Correct Answer:
B (Preventing overpressure or vacuum in the tanks caused by cargo operations and temperature changes)
💡 Venting arrangements equalise tank pressure during cargo operations and temperature changes, preventing structural damage from overpressure and deformation from vacuum.