Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. What must be verified about the righting lever curve after loading?
Your Answer: (Not answered)
Correct Answer: B (That the positive range of the curve and the maximum righting lever meet the criteria)
💡 The intact stability criteria require the righting lever at specified angles, such as 30 or 40 degrees, the maximum righting lever and its angle and the positive range of the curve all to meet the requirements. The initial metacentric height alone does not show stability at large angles of heel.
✗
Question 2. What cargo information and measures are required before loading coal?
Your Answer: (Not answered)
Correct Answer: D (Information on its classification, self-heating tendency and potential to emit methane, with ventilation and testing as prescribed)
💡 The IMSBC Code has specific requirements for coal: information on its group, self-heating tendency and potential to emit methane should be obtained before loading, with ventilation, gas testing for methane and carbon monoxide and restrictions on entry carried out as prescribed, preventing self-heating and explosion.
✗
Question 3. What time window is permitted for an annual survey under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (Within three months before or after the anniversary date, with the next due date counted from the anniversary)
💡 SOLAS provides for the annual survey to be carried out within a window of three months before or after the anniversary date, with the next due date counted from the anniversary. The interval must not be extended at will.
✗
Question 4. What is the minimum daily water ration per person in a survival craft under SOLAS III/7.1?
Your Answer: (Not answered)
Correct Answer: A (1.5 litres)
💡 SOLAS III/7.1 requires not less than 1.5 litres of water per person per day in survival craft, for the required number of days at the rated capacity. One litre is a common misremembering.
✗
Question 5. What do SOLAS and the related conventions address regarding sewage treatment systems?
Your Answer: (Not answered)
Correct Answer: D (The plant must operate and discharge in accordance with the requirements, with attention to the risk of harmful gas)
💡 A sewage treatment plant must be operated and discharge in accordance with MARPOL, and attention paid to the harmful gases which may be produced in the process. The relevant spaces should be ventilated, entry restricted and testing carried out as prescribed to prevent poisoning.
✗
Question 6. What must be considered in manning a ship for polar waters?
Your Answer: (Not answered)
Correct Answer: A (The greater difficulty of operations, the long search and rescue response times and the demands of working in low temperature)
💡 The Polar Code requires account to be taken of the greater difficulty of operations in polar regions, limited search and rescue resources with long response times and the demands of working and responding in low temperature, ensuring sufficient and trained personnel to cope in an emergency.
✗
Question 7. What should be done if the stowage factor does not suit the ship's hold capacity?
Your Answer: (Not answered)
Correct Answer: D (Adjust the quantity loaded according to hold capacity and stability limits, loading in stages or re-allocating the cargo if necessary)
💡 If the cargo is of large stowage factor and the holds are insufficient, or of small stowage factor so that the hull is overstressed, the quantity loaded or the stowage plan should be adjusted according to capacity, stability and strength limits. Loading regardless would cause overloading or insufficient stability.
✗
Question 8. What is the responsibility of the GMDSS radio operator on board?
Your Answer: (Not answered)
Correct Answer: C (Distress, urgency and safety communications, with watchkeeping and recording as required)
💡 Under SOLAS IV and STCW, the holder of a GMDSS certificate is responsible for distress, urgency and safety communications and watchkeeping, and handles public correspondence under the master's authority.
✗
Question 9. What shall be fitted in all accommodation, service spaces and control stations on a passenger ship?
Your Answer: (Not answered)
Correct Answer: D (A fixed fire detection and alarm system)
💡 SOLAS II-2/7: passenger ships shall be fitted with a fixed fire detection and alarm system in all such spaces.
✗
Question 10. Outside an emission control area, what is generally the sulphur limit of fuel oil used on board?
Your Answer: (Not answered)
Correct Answer: A (0.50 per cent m/m)
💡 Under MARPOL Annex VI the global sulphur limit for fuel oil used on board has been 0.50 per cent m/m since 2020, while within an emission control area such as the Baltic, North Sea, North American and United States Caribbean areas it is 0.10 per cent m/m. Using low-sulphur fuel or an equivalent arrangement is acceptable.
✗
Question 11. Where shall the launching appliance for survival craft be located?
Your Answer: (Not answered)
Correct Answer: B (So that launching on either side is safe)
💡 So that launching is safe on the side where the craft is stowed.
✗
Question 12. A 120 m cargo ship has one lifeboat on each side. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (The capacity on each side must accommodate all persons, with at least one boat serving as a rescue boat)
💡 SOLAS requires the capacity on each side of a cargo ship to accommodate all persons on board, with at least one boat meeting the rescue boat requirements. Counting the two boats together would not ensure escape if one side were lost.
✗
Question 13. Which ships are subject to the Enhanced Survey Programme?
Your Answer: (Not answered)
Correct Answer: C (Bulk carriers and tankers)
💡 The ESP applies to bulk carriers and tankers, focusing on cargo and ballast tank areas.
✗
Question 14. What is the principle of assessing stability from the rolling period at sea?
Your Answer: (Not answered)
Correct Answer: D (The rolling period corresponds to the initial metacentric height: a shorter period means excessive stability and a longer one may mean insufficient stability)
💡 The rolling period varies inversely with the square root of the initial metacentric height. A clearly shorter period indicates increased stability from cargo settling or flooding, while a markedly longer period may indicate reduced stability from cargo shifting upwards or flooding. It is a useful aid to judging changes in stability at sea.
✗
Question 15. What does SOLAS address regarding short circuit protection in the electrical system?
Your Answer: (Not answered)
Correct Answer: D (Protective devices on each circuit with selective operation, so a fault does not cause loss of the whole supply)
💡 SOLAS requires protection on each circuit with discrimination, so that a fault in one circuit does not trip the main switchboard or cause total loss of power, affecting propulsion and safety equipment supplies.
✗
Question 16. What assessment and improvement follows emergency drills?
Your Answer: (Not answered)
Correct Answer: A (Analyse the problems found, assess the effectiveness of the procedures and revise them, forming a closed loop)
💡 The ISM Code and good practice require drills to be assessed: the problems found, such as slow response, unclear duties or unavailable equipment, analysed, the effectiveness of the existing procedures and training evaluated and revisions made, so that drills genuinely drive improvement of the system in a closed loop.
✗
Question 17. A ship is 180 m in length. What is the minimum number of lifebuoys under SOLAS III/7.1?
Your Answer: (Not answered)
Correct Answer: A (18)
💡 SOLAS III/7.1 sets bands by length: under 60 m — 8; 60 to 120 m — 12; 120 to 180 m inclusive — 18; over 180 m — 24. A length of 180 m falls in the third band.
✗
Question 18. A ship of 3200 GT. Under SOLAS V/19, is a second radar required?
Your Answer: (Not answered)
Correct Answer: A (Yes; ships of 3000 GT and above must carry a second radar)
💡 SOLAS V/19 requires ships of 3000 GT and above to be fitted with a second radar operating independently. At 3200 GT the ship is above the threshold.
✗
Question 19. After a ship is detained by PSC, what is the correct course of action?
Your Answer: (Not answered)
Correct Answer: D (Rectify the deficiencies before departure and apply for a re-inspection, fulfilling the duty to report to the flag State, the recognised organisation and the company)
💡 A detained ship should rectify the deficiencies before departure, or within the permitted period, apply for a port State re-inspection and be confirmed before leaving, and report to the flag State, recognised organisation and company as required with the rectification plan. Sailing without rectification aggravates the consequences and affects the future PSC record.
✗
Question 20. What is the fundamental purpose of the charts or ECDIS required by SOLAS V/19?
Your Answer: (Not answered)
Correct Answer: B (To give the navigator the geographical and hazard information needed to plan and monitor the voyage)
💡 Charts or ECDIS are required so that the navigator can plan the route, monitor the ship's position and identify dangers. They are navigational safety equipment.
✗
Question 21. What duration shall the lifejacket light battery provide?
Your Answer: (Not answered)
Correct Answer: B (8 hours of continuous operation)
💡 At least 8 hours of continuous operation.
✗
Question 22. Which is NOT an objective of SOLAS Chapter II-2?
Your Answer: (Not answered)
Correct Answer: B (Reducing construction cost)
💡 Reducing construction cost is not among the objectives.
✗
Question 23. What must the PWOM contain regarding operational measures for polar waters?
Your Answer: (Not answered)
Correct Answer: A (Ice assessment in voyage planning, ship capability limitations, emergency procedures and training requirements)
💡 The Polar Water Operational Manual must cover voyage planning, ice assessment, the ship's ice class capabilities and limitations, operation of equipment in low temperature, emergency procedures and training, guiding the master's decisions in ice.
✗
Question 24. Which systems shall be used to receive navigational warnings?
Your Answer: (Not answered)
Correct Answer: C (Maritime safety information systems such as NAVTEX and SafetyNET)
💡 Systems such as NAVTEX and SafetyNET.
✗
Question 25. The function of flame arresters in a tanker cargo tank venting system is to:
Your Answer: (Not answered)
Correct Answer: C (prevent external flame from entering the cargo tanks)
💡 SOLAS II-2/4 requires flame arresters to prevent external flame from passing through vent pipes into cargo tanks.
✗
Question 26. The use of the automatic pilot shall be such that:
Your Answer: (Not answered)
Correct Answer: C (in congested waters or restricted visibility the helmsman shall take over hand steering under the direct control of the OOW)
💡 SOLAS V/19: in congested waters or restricted visibility the helmsman shall take over hand steering under the direct control of the OOW.
✗
Question 27. What does SOLAS address regarding resetting fire detection alarms?
Your Answer: (Not answered)
Correct Answer: A (Alarms should be reset only after the fire condition has been cleared, preventing the mask of a real fire by careless resetting)
💡 SOLAS requires detection alarms to be reset only after the fire condition has been dealt with, preventing the watchkeeper from resetting alarms merely to silence them and thereby concealing a real fire with serious consequences.
✗
Question 28. What fire rating does SOLAS normally require for the boundaries of main vertical zones?
Your Answer: (Not answered)
Correct Answer: B (A-60 class)
💡 SOLAS requires the boundaries between main vertical zones to be class A-60 divisions, confining a fire to the zone in which it starts and preventing spread to adjacent zones.
✗
Question 29. What does SOLAS require for doors in escape routes from accommodation and machinery spaces?
Your Answer: (Not answered)
Correct Answer: A (They must be capable of being opened from inside without a key, with the route kept clear)
💡 SOLAS requires doors in escape routes to be openable from inside without a key, with the route kept clear. Any locking or one-way arrangement could trap persons during an emergency evacuation, a serious hazard.
✗
Question 30. In which spaces must ceilings and linings be of non-combustible material?
Your Answer: (Not answered)
Correct Answer: A (In enclosures of stairways and corridors forming escape routes)
💡 SOLAS requires non-combustible linings and ceilings in critical spaces such as stairway enclosures and corridors serving as escape routes, limiting the spread of fire and keeping the escape route safe.
✗
Question 31. What is required for the height of liferaft stowage?
Your Answer: (Not answered)
Correct Answer: A (Stowed at a height allowing the raft to float free and allowing persons to board and handle it)
💡 A liferaft should be stowed at a height that allows it to float free, clear of deck structures, and that permits persons to board and handle it, normally on a dedicated rack on the boat deck. Too high makes boarding difficult; too low risks damage by seas or prevents free floating.
✗
Question 32. What additional safety is required when carrying timber deck cargo?
Your Answer: (Not answered)
Correct Answer: A (Enhanced securing, safe access and unobstructed visibility, with attention to deck load and stability)
💡 Timber deck cargo requires enhanced securing with the prescribed methods and attention to the weight gained by water absorption, safe access for the crew and an unobstructed view from the bridge, with deck loading and stability calculated including the effects of water absorption and ice accretion, in accordance with the timber deck cargo requirements of the Load Line Convention.
✗
Question 33. The quantity of extinguishing medium stored for a fixed gas fire-extinguishing system shall be sufficient for:
Your Answer: (Not answered)
Correct Answer: B (the volume of the largest protected space)
💡 SOLAS II-2/10 requires the stored quantity of medium to be sufficient for the largest protected space.
✗
Question 34. Where an enclosed means of escape is provided from a category A machinery space, what minimum fire protection does SOLAS II-2/13.4.3 require?
Your Answer: (Not answered)
Correct Answer: C (A-60 class division)
💡 SOLAS II-2/13.4.3 requires the enclosed means of escape from a category A machinery space to be of A-60 standard so that the route remains usable during a machinery space fire.
✗
Question 35. What special requirement applies to life-saving appliances on ships operating in polar waters?
Your Answer: (Not answered)
Correct Answer: A (They must function at low temperature, with measures to extend survival time taken into account)
💡 The Polar Code requires life-saving appliances to function at low temperatures and for measures to be taken to extend survival time, such as thermal protection and collective survival equipment. Ordinary water requirements alone do not suffice.
✗
Question 36. What is the usual maximum validity of a Cargo Ship Safety Equipment Certificate?
Your Answer: (Not answered)
Correct Answer: D (Five years, with annual and periodical surveys)
💡 Under SOLAS I/12 the Cargo Ship Safety Equipment Certificate has a usual validity of not more than five years, with annual and periodical surveys within it. It remains valid only if the surveys are carried out and endorsed, the safety equipment provision and performance being the focus of the survey.
✗
Question 37. What is the first action after a fire breaks out at sea?
Your Answer: (Not answered)
Correct Answer: B (Raise the fire alarm at once, inform the bridge, organise firefighting per the muster list and consider reporting and seeking assistance)
💡 On discovering a fire, the fire alarm must be raised at once and firefighting organised under the muster list, with the bridge and master informed. The situation is then assessed to decide whether to seek assistance from nearby vessels or ashore and whether to alter course or speed, for example to keep the seat of the fire downwind. Delaying the alarm is not acceptable.
✗
Question 38. After a dead-ship condition, propulsion shall be restorable within:
Your Answer: (Not answered)
Correct Answer: D (30 minutes)
💡 Propulsion shall be restored within 30 minutes of a dead-ship condition.
✗
Question 39. How should near-miss reporting be organised, so that people are not penalised for reporting?
Your Answer: (Not answered)
Correct Answer: B (Create a climate in which the reporter is not punished, encouraging voluntary reporting of near misses and hazards)
💡 Effective safety management requires a climate that encourages reporting: it should be clear that reporting a near miss or hazard does not lead to punishment of the reporter, apart from wilful breach, so that the crew is willing to report. Otherwise hazards are concealed and small problems develop into accidents.
✗
Question 40. If the Inmarsat equipment fails while a ship is in sea area A3, what alternative does SOLAS permit?
Your Answer: (Not answered)
Correct Answer: A (Using MF/HF equipment to meet the distress and safety communication requirements)
💡 Where the primary satellite equipment fails, the ship must use MF/HF to maintain distress and safety communication in sea area A3. Reliance on another ship or on repair is not acceptable.
✗
Question 41. A survey found the nautical publications on board out of date. What does SOLAS address?
Your Answer: (Not answered)
Correct Answer: C (A deficiency; publications must be kept corrected up to date, as out-of-date information affects safety of navigation)
💡 SOLAS V/27 requires charts and nautical publications to be kept corrected to the latest information and they are checked at survey. Out-of-date publications are a deficiency affecting safety of navigation, particularly in confined waters and on an unfamiliar coast, where they create a risk of grounding.
✗
Question 42. Which document must be kept on the bridge for use by the watchkeepers?
Your Answer: (Not answered)
Correct Answer: C (A table of ship particulars)
💡 A table of ship particulars is kept on the bridge for reference by the watch.
✗
Question 43. What crew preparation is required before entering ice in polar waters?
Your Answer: (Not answered)
Correct Answer: D (Special polar operations training, clear emergency duties for ice conditions and drills of emergency procedures at low temperature)
💡 The Polar Code requires relevant training and familiarisation before entering polar waters, covering the contents of the PWOM, ice operating procedures and the use of emergency and life-saving equipment in low temperature, with the duties of each position in an ice emergency made clear and corresponding drills held.
✗
Question 44. What happens to the statutory certificates when a ship changes to a new owner and flag?
Your Answer: (Not answered)
Correct Answer: B (The existing certificates cease to be valid and new ones must be issued by the new flag Administration or its authorised body after survey)
💡 SOLAS requires certificates to be issued by the Administration of the State whose flag the ship is entitled to fly. After a change of flag the existing certificates are no longer valid and new ones must be issued following survey by the new Administration. Using the old certificates is a serious deficiency.
✗
Question 45. What should be done about a failed water ingress detector on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (Repair promptly and, pending repair, increase manual checks such as sounding the bilges, with records kept)
💡 A failed water ingress detector should be repaired as soon as possible and, pending repair, manual checks increased, such as periodic sounding of holds, ballast tanks and bilges, with the failure and the temporary measures recorded. Switching the system off would remove the warning of flooding and is a serious deficiency.
✗
Question 46. A ship needed to enter a cargo hold. The PSCO enquired about the enclosed space entry permit system. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: A (A permit system with testing of oxygen and harmful gases before entry and retention of records)
💡 SOLAS II-1/3-6 and the IMO resolutions require an entry permit system for enclosed spaces, with testing of oxygen (normally between 19.5 and 23 per cent) and toxic and flammable gases before granting the permit, and records retained.
✗
Question 47. What is the purpose of sailing directions among the nautical publications required on board?
Your Answer: (Not answered)
Correct Answer: C (To provide written information on navigational conditions, dangers and coastal features of the area)
💡 Sailing directions give written information on navigational conditions, dangers, ports and coastal features, complementing the charts, and are among the publications required by SOLAS.
✗
Question 48. When trading outside sea area A1, NAVTEX is one of the principal means of receiving MSI. Which is the international NAVTEX frequency?
Your Answer: (Not answered)
Correct Answer: D (518 kHz)
💡 The international NAVTEX service uses 518 kHz. 490 kHz is the national NAVTEX frequency and 2182 kHz is the MF radiotelephony distress frequency.
✗
Question 49. The packaging of dangerous goods shall:
Your Answer: (Not answered)
Correct Answer: C (comply with the packing requirements of the IMDG Code and be properly marked and labelled)
💡 SOLAS VII/3 requires packaging in accordance with the IMDG Code with proper marking and labelling.
✗
Question 50. What is the maximum interval between ship security drills required by the ISPS Code?
Your Answer: (Not answered)
Correct Answer: C (Three months)
💡 ISPS Code Part A/13 and SOLAS XI-2 require ship security drills at intervals of not more than three months, with additional drills where the security level changes.
✗
Question 51. Where one of the two means of escape from a machinery space is an enclosed route, what does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (It must be protected by A-60 class divisions with self-closing doors and lighting)
💡 SOLAS requires an enclosed means of escape from a machinery space to be protected by A-60 class divisions with self-closing fire doors and lighting, so that it remains usable as an escape route during a machinery space fire.
✗
Question 52. What does the SOLAS II-2 requirement for the total capacity of fire pumps address?
Your Answer: (Not answered)
Correct Answer: B (The aggregate capacity must meet the prescribed figure and the remaining pumps must still suffice if one is out of action)
💡 SOLAS II-2 specifies the aggregate capacity and requires that, with any one pump out of action, the remaining pumps still deliver the required quantity and pressure, providing redundancy.
✗
Question 53. What is required for stability calculation after loading is completed?
Your Answer: (Not answered)
Correct Answer: C (Calculate the stability for the departure and arrival conditions and confirm compliance with the stability information)
💡 SOLAS requires the stability for departure and arrival conditions to be calculated and confirmed against the stability information, checking parameters such as metacentric height and righting levers. Any exceedance requires adjustment.
✗
Question 54. What does the Polar Code address regarding equipment for low temperature in polar waters?
Your Answer: (Not answered)
Correct Answer: A (Materials and operating temperatures of essential equipment must suit the low temperatures, preventing brittle fracture and failure)
💡 The Polar Code requires essential equipment, materials and systems of a ship in polar waters to be designed for low temperatures, preventing failure through brittle fracture of steel, increased viscosity of hydraulic oil or reduced battery capacity.
✗
Question 55. What is required for the first aid kit in a lifeboat?
Your Answer: (Not answered)
Correct Answer: C (A first aid kit of the prescribed type with medicines within their expiry dates)
💡 SOLAS requires a lifeboat to carry a first aid kit of the prescribed type with the contents within their expiry dates. Out-of-date medicines may be ineffective after abandonment and are a common deficiency at inspection.
✗
Question 56. In which circumstances must the ship security assessment be updated?
Your Answer: (Not answered)
Correct Answer: C (On major changes to the ship's structure, manning or operations, or on a change in the security situation)
💡 ISPS Code Part A/6 requires the ship security assessment to be reviewed and updated on major changes to the ship's structure, personnel or operations, or on a security incident or change of security level, keeping it consistent with the actual situation.
✗
Question 57. What is the purpose of a bulk carrier's Loading Manual?
Your Answer: (Not answered)
Correct Answer: D (It provides the permissible stresses, stability, shear force and bending moment data for loading conditions, guiding safe loading and ballasting)
💡 Under SOLAS XII/11 and related requirements a bulk carrier should carry an approved Loading Manual stating the permissible stresses, stability, shear force and bending moment data for loading conditions and guidance on ballasting and loading sequence, enabling the crew to prepare the loading plan and check stress and stability, preventing overloading and structural damage.
✗
Question 58. What do SOLAS and good practice require for emergency instructions after a distress?
Your Answer: (Not answered)
Correct Answer: D (Muster, embarkation and abandonment instructions to crew and passengers, organised in accordance with the muster list)
💡 SOLAS requires the muster list, signs and emergency announcements to enable crew and passengers to proceed in an orderly way to the muster and embarkation stations on abandonment. Independent action causes confusion and casualties.
✗
Question 59. What is required when a ship deviates from the planned route?
Your Answer: (Not answered)
Correct Answer: D (Assess the reason for and the risk of the deviation, informing the master as necessary and recording it in the log)
💡 When a ship deviates because of avoidance, sheltering or an emergency, the navigational conditions and risks in the area should be assessed and a method of rejoining the route established, with the master informed as necessary and the matter recorded under the SMS, avoiding blind navigation into a dangerous area.
✗
Question 60. The voyage plan shall include:
Your Answer: (Not answered)
Correct Answer: A (a berth-to-berth plan giving due consideration to navigational hazards including safe speed)
💡 SOLAS V/34: the voyage plan covers the whole passage from berth to berth, giving due consideration to navigational hazards and safe speed.
✗
Question 61. Why must fire nozzles be of the water-fog and jet dual-purpose type?
Your Answer: (Not answered)
Correct Answer: B (spray suiting oil and electrical fires and covering the approach, the jet reaching a distance and cooling the plating)
💡 One nozzle has to serve fires of quite different kinds. On a surface of burning oil, spray covers the fire, holds off the radiation and cools the compartment, whereas a solid jet breaks the oil about and spreads the fire with it; on electrical equipment and in live spaces spray is what may be used, and then only from the distance the practice allows. A water curtain also covers the party as they close on the seat of the fire. Yet to strike from a distance, or to cool a bulkhead or a cargo surface, a solid column is wanted, which is why the nozzle changes between the two without being swapped. Sparing fresh water and ease of carrying are not the point, and calling the jet a spare misreads what the fire demands.
✗
Question 62. What does SOLAS V and STCW require regarding the arrangement of navigational watches?
Your Answer: (Not answered)
Correct Answer: B (Watch arrangements must ensure that personnel are not impaired by fatigue in carrying out their duties)
💡 SOLAS V/34 and STCW require watch schedules that prevent fatigue from impairing the performance of duties, with prescribed minimum rest hours. Fatigue management is continuous, not a night-time concern only.
✗
Question 63. What applies when security level 3 is set?
Your Answer: (Not answered)
Correct Answer: C (Further specific protective measures until the incident is resolved)
💡 Further specific protective measures until the incident is resolved.
✗
Question 64. What is the requirement for a spare radio antenna on board?
Your Answer: (Not answered)
Correct Answer: D (A spare antenna and the means to rig it must be provided so communication is possible if the main antenna fails)
💡 SOLAS requires a spare antenna and means of rigging it appropriate to the sea area, so that radio communication can be restored quickly. A rope is not an acceptable substitute.
✗
Question 65. Regarding lifeboat provision for cargo ships, which is correct?
Your Answer: (Not answered)
Correct Answer: D (lifeboats for all persons on board shall be provided on each side)
💡 SOLAS III/31 requires lifeboats for all persons on each side of a cargo ship, or liferafts meeting equivalent conditions.
✗
Question 66. An echo sounder shall be fitted on:
Your Answer: (Not answered)
Correct Answer: D (passenger ships on international voyages and cargo ships of 500 GT and above)
💡 SOLAS V/19: passenger ships on international voyages and cargo ships of 500 GT and above shall be fitted with an echo sounder.
✗
Question 67. A ship's enclosed escape route from the machinery space was used to store spare parts. What is the finding?
Your Answer: (Not answered)
Correct Answer: C (A serious deficiency, because the enclosed escape route must remain clear for evacuation)
💡 SOLAS requires the enclosed escape route to be kept clear for emergency evacuation. Using it to store articles obstructs evacuation and adds fire load, a deficiency seriously affecting safety.
✗
Question 68. What is the principle for stowing survival craft?
Your Answer: (Not answered)
Correct Answer: A (So that they can be launched quickly and safely under unfavourable conditions)
💡 They shall be stowed so that they can be launched quickly and safely even under unfavourable conditions.
✗
Question 69. For a ship with no emergency generator, for how long shall the GMDSS reserve source of energy supply?
Your Answer: (Not answered)
Correct Answer: C (6 hours)
💡 SOLAS IV/13: the reserve source shall be capable of supplying for 6 hours on ships without an emergency generator.
✗
Question 70. The isolating valve on the fire main serving the accommodation side has long been seized and cannot be operated. How should this be judged?
Your Answer: (Not answered)
Correct Answer: D (Fire main isolating valves must be operable at all times; being seized is a deficiency affecting the isolating function)
💡 Isolating valves on the fire main are used to isolate a damaged section of piping so that the rest of the system still receives water. They must be capable of manual operation at all times. Being seized deprives them of their isolating function and is a deficiency affecting the reliability of the firefighting system, which should be rectified.
✗
Question 71. SOLAS Chapter XII mainly applies to which type of ship?
Your Answer: (Not answered)
Correct Answer: D (Bulk carriers)
💡 Bulk carriers.
✗
Question 72. What checking of survival craft markings is required?
Your Answer: (Not answered)
Correct Answer: A (Confirm the ship's name, port of registry and number of persons the craft can accommodate are clearly and completely marked)
💡 SOLAS requires survival craft to be clearly marked with the ship's name, port of registry and the number of persons it can accommodate. Inspection should confirm the markings are clear, durable and complete. Illegible markings hamper identification of the ship by rescuers and judgement of the craft's capacity, and are a common deficiency.
✗
Question 73. What do SOLAS and the Load Line Convention address regarding the height of coamings at openings in the freeboard deck?
Your Answer: (Not answered)
Correct Answer: A (Coamings must reach the prescribed height to prevent sea water entering spaces below)
💡 SOLAS and the Load Line Convention require openings in the freeboard deck leading to spaces below to have coamings of the prescribed height with effective closing appliances, preventing water shipped on deck from entering and affecting stability.
✗
Question 74. What does COLREG require regarding sound signals in areas of dense traffic?
Your Answer: (Not answered)
Correct Answer: A (Manoeuvring and warning signals must be given as prescribed, with light signals where appropriate)
💡 COLREG requires vessels in sight of one another to give the prescribed manoeuvring signals, such as one short blast for a starboard alteration, and to sound warning signals in narrow channels or at a bend. Sound signals are an important means of indicating intention and warning others.
✗
Question 75. What does SOLAS address regarding electrical equipment in a paint locker?
Your Answer: (Not answered)
Correct Answer: C (Explosion-protected equipment or no electrical equipment within the space)
💡 SOLAS requires explosion-protected equipment in a paint locker, or no electrical equipment inside it, such as lighting fitted outside, preventing an electrical spark from igniting paint vapour.
✗
Question 76. What is required for the maintenance of water ingress detectors on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: B (Tested at regular intervals and kept operational, with tests and maintenance recorded)
💡 SOLAS requires the water ingress detection system of a bulk carrier to be tested and maintained at regular intervals with records kept, so that it alarms reliably when flooding occurs. Long neglect of testing means the system may fail unnoticed.
✗
Question 77. What overload protection is required for electrical equipment?
Your Answer: (Not answered)
Correct Answer: C (Overload protection for essential motors and cables, preventing overheating which damages insulation and causes fire)
💡 SOLAS requires overload protection for essential motors, cables and distribution equipment, operating to trip or alarm on overload, preventing prolonged overheating from ageing the insulation and causing an electrical fire, particularly in the high temperature environment of a machinery space.
✗
Question 78. What does SOLAS address regarding lighting and marking of survival craft stowage?
Your Answer: (Not answered)
Correct Answer: D (Lighting and markings at the stowage positions and embarkation stations, enabling identification and operation at night)
💡 SOLAS requires the stowage positions of survival craft and the embarkation stations to be provided with lighting and clear markings such as signs or reflective tape, enabling persons to find the boarding positions and appliances quickly at night or in dense smoke.
✗
Question 79. Where must the muster list be posted?
Your Answer: (Not answered)
Correct Answer: A (On the bridge and in the spaces where emergency duties are assigned)
💡 The muster list is posted on the bridge and at each station where emergency duties are performed.
✗
Question 80. What is the purpose of the water ingress detection system required on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: B (To give an alarm when water enters the cargo holds and fore and aft spaces, enabling the crew to detect and deal with it promptly)
💡 Under SOLAS XII/12 a bulk carrier should have water ingress detection and alarm systems for the cargo holds and the forepeak and similar spaces, giving an alarm on the bridge promptly when water enters so that the crew can detect the ingress early and take pumping, leak-hunting and damage control measures, preventing the situation from worsening. The testing of the system should be kept effective.
✗
Question 81. What is required of the torch carried in survival craft?
Your Answer: (Not answered)
Correct Answer: D (It must be watertight and capable of continuous illumination, provided in the craft for use at night)
💡 SOLAS requires survival craft to carry a watertight torch, normally one per boat or as prescribed, providing light at night after abandonment for checking the condition of the craft, signalling or assisting a person. An ordinary torch is not waterproof and would fail at sea.
✗
Question 82. What is the role of the voyage data recorder in casualty investigation?
Your Answer: (Not answered)
Correct Answer: B (Providing data such as position, course and speed, radar images and bridge audio for investigation)
💡 SOLAS requires the VDR to record navigational and operational data including position, course and speed, radar images, bridge audio and alarms, providing objective evidence for investigation. The data is protected and must not be used at will.
✗
Question 83. What must a company do after a non-conformity is found in an internal or external audit?
Your Answer: (Not answered)
Correct Answer: C (Analyse the root cause, take corrective action within the prescribed period and verify its effectiveness)
💡 The ISM Code requires non-conformities found at audit to be analysed for root cause, with corrective action taken and completed within the prescribed period and its effectiveness verified, preventing recurrence.
✗
Question 84. Survival craft launching appliances shall be capable of being operated:
Your Answer: (Not answered)
Correct Answer: B (under unfavourable conditions of trim and list)
💡 SOLAS III/16 requires launching appliances to operate under unfavourable conditions of trim and list.
✗
Question 85. What should be included in a drill record?
Your Answer: (Not answered)
Correct Answer: A (The date, time, position, scenario, participants, equipment used, problems found and improvement action)
💡 A drill record should show that the drill was genuine: the date and time, the ship's position, the scenario such as a fire in the machinery space, the participants, the equipment and craft used, the problems found and the improvement action. Rote copies or records inconsistent with reality are treated as falsification.
✗
Question 86. Which spaces must emergency lighting cover at a minimum under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (Embarkation stations, survival craft stowage positions, escape routes, machinery spaces and the bridge, among other essential spaces)
💡 SOLAS requires emergency lighting for essential spaces including embarkation stations, survival craft stowage positions, escape routes, machinery spaces, the bridge and fire control stations, supporting abandonment and emergency operations.
✗
Question 87. What should be done when a detection system alarms without an actual fire?
Your Answer: (Not answered)
Correct Answer: C (Establish the cause, such as a contaminated detector, a fault or a real latent hazard, and deal with it before resetting)
💡 When the cause of an alarm is unclear, it should be established whether a detector is contaminated, there is a circuit fault or a real latent hazard exists, such as concealed smouldering, and dealt with before resetting. Simply resetting or disabling the circuit conceals a real danger, a serious concern.
✗
Question 88. What is required regarding the deck log book?
Your Answer: (Not answered)
Correct Answer: C (Navigational, watchkeeping and significant events must be entered truthfully as required, without alteration or falsification)
💡 SOLAS and good practice require the deck log to record the position, course and speed, weather, equipment condition and significant events truthfully and promptly. The log is important evidence in navigation and casualty investigation, and alteration or falsification has serious consequences.
✗
Question 89. Which of the following is NOT part of an abandon-ship drill?
Your Answer: (Not answered)
Correct Answer: A (cargo handling)
💡 SOLAS III/19: cargo handling is not part of an abandon-ship drill; mustering, checking dress and launching lifeboats are.
✗
Question 90. What is the principle for the inspection and maintenance of portable fire extinguishers?
Your Answer: (Not answered)
Correct Answer: B (Their pressure, seals, nozzles and securing should be checked regularly, with maintenance or recharging at the required intervals and records kept)
💡 Under SOLAS II-2/10 and the maintenance requirements portable fire extinguishers should have their pressure indication, seals, nozzles and securing checked regularly and be maintained or recharged at the required intervals, by an approved service provider where applicable, with records kept, ensuring they are always available.
✗
Question 91. Regarding launching and recovery of survival craft:
Your Answer: (Not answered)
Correct Answer: B (training shall be given in both launching and recovery)
💡 SOLAS III/19 requires training in both launching and recovery of survival craft.
✗
Question 92. What should be done if an electronic aid such as GPS shows a jump in position?
Your Answer: (Not answered)
Correct Answer: D (Switch at once to other means such as radar or visual bearings for cross-checking, establish the cause and record and report the matter)
💡 If GPS shows a jump, drift or loss of signal, other means such as radar and visual bearings should be used at once to cross-check the position, the cause established, for example signal interference or equipment failure, and the matter recorded and reported, preventing grounding from an error in a single aid.
✗
Question 93. Ships shall be provided with heading indication by means of:
Your Answer: (Not answered)
Correct Answer: D (a gyro-compass or magnetic compass providing heading indication on the bridge)
💡 SOLAS V/19 requires heading indication equipment providing heading to the bridge.
✗
Question 94. What is the essential capability of the windlass while at anchor?
Your Answer: (Not answered)
Correct Answer: D (Reliably braking the anchor so that it will not drag)
💡 SOLAS II-1/31: the windlass must be capable of holding the anchor reliably in bad weather.
✗
Question 95. What are the key points in checking the falls of a launching appliance?
Your Answer: (Not answered)
Correct Answer: C (Check for broken wires, corrosion, deformation and the security of the terminations, replacing when beyond the limit)
💡 The falls of a launching appliance should be checked for the number of broken wires, corrosion, kinks and deformation and for the security of the terminations, replaced at once when beyond the rejection criteria. Failure of the falls would drop the craft during launching with fatal consequences.
✗
Question 96. What must the cargo securing manual contain under SOLAS VI/5 and the CSS Code?
Your Answer: (Not answered)
Correct Answer: C (Securing methods for the various cargo units, specifications of securing equipment and methods of strength verification)
💡 SOLAS VI/5 and the CSS Code require the cargo securing manual to contain the securing methods for the various cargo units, the specification and number of securing devices, methods of strength verification and inspection requirements, for correct securing by the crew.
✗
Question 97. What alternative measures are required if a fire detection system fails?
Your Answer: (Not answered)
Correct Answer: B (Repair promptly; pending repair, increase patrols of the affected spaces under the procedure and keep records)
💡 If a detection system fails it should be repaired promptly and, pending repair, patrols of the affected spaces increased under the procedure with records kept, preventing a fire from going unnoticed while the system is out of action.
✗
Question 98. The self-contained breathing apparatus in a firefighter's outfit shall be capable of being used for at least:
Your Answer: (Not answered)
Correct Answer: C (30 minutes)
💡 SOLAS II-2/10: the self-contained breathing apparatus in a firefighter's outfit shall be capable of being used for at least 30 minutes.
✗
Question 99. What determines the type of protection required for electrical equipment in a hazardous area?
Your Answer: (Not answered)
Correct Answer: C (Whether the type of equipment matches the hazard level of the area, such as the zone classification for explosive gas atmospheres)
💡 SOLAS and the IEC standards prescribe the types of protection permitted according to the zone classification of the hazardous area, such as zones 0, 1 and 2. The equipment type must match the area, or it may become a source of ignition.
✗
Question 100. What are the duties of the deck watch during cargo operations on a tanker?
Your Answer: (Not answered)
Correct Answer: B (Monitor piping, valves and tanks, detecting leaks, overflow or abnormalities and taking action)
💡 During cargo operations on a tanker a deck watch must be maintained, monitoring pipeline joints for leakage, tank levels and pressures, overflow and unusual noise, with communication kept with the engine room and the terminal, so that abnormalities are detected and dealt with promptly.