Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. What must be carefully considered when loading high density cargo into a bulk carrier?
Your Answer: (Not answered)
Correct Answer: C (Hull structural strength and the loading rate)
💡 Hull structural strength and the rate of loading must be controlled.
✗
Question 2. What does SOLAS address regarding the two steel ladders forming the means of escape from a machinery space?
Your Answer: (Not answered)
Correct Answer: A (The two ladders must be distant from each other, one of which may be enclosed, so that one remains usable if the other is blocked)
💡 SOLAS requires two means of escape from a category A machinery space, distant from each other, normally two steel ladders one of which may be enclosed, so that personnel can withdraw by the other if one exit is blocked by fire or smoke. Adjacent ladders or a common exit would put both out of use at once.
✗
Question 3. A vessel uses ECDIS as her primary means of navigation. Which back-up arrangement satisfies SOLAS chapter V when the superintendent checks it before departure?
Your Answer: (Not answered)
Correct Answer: C (an appropriate back-up arrangement on board, for example a full set of current official paper charts of the right scale, or a second ECDIS on an independent power supply)
💡 Regulation V/19 requires due allowance for ECDIS failure; accepted back-ups are a full set of current official paper charts, or a second ECDIS on independent power, or another type-approved arrangement. Data discs, USB sticks and printouts preserve data but are not an independently usable means of navigation.
✗
Question 4. The bow structure requirements for bulk carriers mainly address:
Your Answer: (Not answered)
Correct Answer: B (carriage of high-density solid bulk cargoes such as ore)
💡 SOLAS XII/9: the bow structure requirements address the carriage of high-density solid bulk cargoes such as ore.
✗
Question 5. What minimum duration of air supply does SOLAS II-2/10.1 require for the self-contained compressed air breathing apparatus of a firefighter's outfit?
Your Answer: (Not answered)
Correct Answer: A (30 minutes)
💡 SOLAS II-2/10.1 requires the self-contained breathing apparatus to have a capacity of at least 30 minutes of air. Do not confuse this with the 3-hour electric safety lamp or the 30 m lifeline.
✗
Question 6. What must be recorded in the radio log?
Your Answer: (Not answered)
Correct Answer: B (Distress, urgency and safety traffic, equipment tests and faults and the watchkeeping arrangements)
💡 SOLAS IV/17 requires the radio log to record the content and time of distress, urgency and safety traffic, the daily, weekly and other tests of equipment, faults and repairs and the watchkeeping arrangements, making the management of the equipment and the communication traceable.
✗
Question 7. What is required regarding the difference between indicated and actual rudder angle?
Your Answer: (Not answered)
Correct Answer: D (The difference must be within the permitted tolerance and corrected if exceeded)
💡 SOLAS and good seamanship require the difference between the indicated and actual rudder angle to be within the permitted tolerance. An excessive difference, such as more than five degrees, misleads the helmsman and the officer, and should be found and corrected at trials.
✗
Question 8. On discovering equipment that may endanger safety, the master shall:
Your Answer: (Not answered)
Correct Answer: A (Take immediate precautions and, if necessary, report and seek assistance)
💡 Take immediate precautions and, if needed, report and seek assistance.
✗
Question 9. What does a SIRE inspection focus on regarding equipment maintenance?
Your Answer: (Not answered)
Correct Answer: D (Records of execution of the maintenance programme, the condition of critical equipment and records of faults and repairs)
💡 On equipment maintenance a SIRE inspection focuses on whether the planned maintenance programme is actually carried out at the prescribed intervals with records, the real condition of critical equipment such as the main engine, steering gear, fire pumps and emergency source, records of faults and repairs and the identification of equipment and the performance of routine checks.
✗
Question 10. What does SOLAS address regarding the helmet and boots of a firefighter's outfit?
Your Answer: (Not answered)
Correct Answer: C (A helmet able to withstand impact and protect the head, and boots resistant to puncture and electrically insulating)
💡 SOLAS requires a rigid helmet able to withstand impact with a face shield, and boots resistant to puncture and electrically insulating. An ordinary safety helmet and rubber boots do not meet the requirements for firefighting.
✗
Question 11. The life-saving drill records are found identical to each other and inconsistent with the official log book. The finding is?
Your Answer: (Not answered)
Correct Answer: C (Drill records must reflect reality; false records are an SMS execution deficiency that may lead to detention and investigation)
💡 Life-saving and fire drills should genuinely be held and truthfully recorded with the time, content and participants in the official log book and similar records. Records that do not match reality, or are identical, suggest the drills may not have been genuinely held. This is a serious SMS execution and emergency preparedness deficiency that may lead to detention or even investigation.
✗
Question 12. What protection is required when handling corrosive cargo on a chemical tanker?
Your Answer: (Not answered)
Correct Answer: C (Appropriate protective equipment such as acid-resistant gloves, face protection and protective clothing, with washing facilities available)
💡 SOLAS and the IBC Code require appropriate personal protective equipment for handling corrosive or toxic chemicals, such as resistant gloves, face and eye protection and protective clothing, with emergency washing facilities available for prompt treatment on contact. The ship should carry her own protective equipment.
✗
Question 13. What is required for the height of liferaft stowage?
Your Answer: (Not answered)
Correct Answer: A (Stowed at a height allowing the raft to float free and allowing persons to board and handle it)
💡 A liferaft should be stowed at a height that allows it to float free, clear of deck structures, and that permits persons to board and handle it, normally on a dedicated rack on the boat deck. Too high makes boarding difficult; too low risks damage by seas or prevents free floating.
✗
Question 14. An ECDIS is found using non-official electronic charts instead of official ENCs. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Using non-official charts affects navigational safety, a navigational safety deficiency to be corrected)
💡 An ECDIS should use electronic navigational charts issued by an official hydrographic office, or approved equivalent data, to ensure that navigational information is accurate and official. Using non-official charts may lead to inaccurate information endangering navigational safety. It is a deficiency to be corrected.
✗
Question 15. What is required for closing appliances on overboard discharges below the load line?
Your Answer: (Not answered)
Correct Answer: B (Effective closing appliances operable from above the bulkhead deck, preventing back flooding)
💡 SOLAS and the Load Line Convention require discharges and inlets below the load line to have effective closing appliances such as non-return valves or cocks, operable from above the bulkhead deck, preventing sea water from entering. Temporary plugs of wood are not reliable.
✗
Question 16. A cargo ship safety equipment certificate expires while the ship is still at sea on her return voyage. What may the Administration do?
Your Answer: (Not answered)
Correct Answer: A (Grant an extension of not more than three months so the ship may reach her port of survey)
💡 SOLAS I/14 permits an extension of up to three months for a certificate expiring during a voyage, so that the ship may reach the port where she is to be surveyed.
✗
Question 17. How should hazard identification and risk assessment be carried out on board?
Your Answer: (Not answered)
Correct Answer: B (Identify hazards and assess risks for shipboard operations and equipment and take control measures accordingly)
💡 The ISM Code requires hazard identification and risk assessment on board for operations and equipment, covering routine and non-routine work and new equipment and new operations, from which control measures are decided and incorporated into procedures and checklists, bringing risks under control in advance.
✗
Question 18. How must Class 1 explosives be segregated from Class 4 flammable solids?
Your Answer: (Not answered)
Correct Answer: B (Segregation is required as set out in the Code and the Cargo Securing Manual)
💡 Incompatible dangerous goods must be segregated in accordance with the Code and the Cargo Securing Manual.
✗
Question 19. Where should the damage control plan normally be posted?
Your Answer: (Not answered)
Correct Answer: D (On the bridge)
💡 Under SOLAS II-1/19 the damage control plan should be posted on the bridge so that the navigators can quickly consult the boundaries of the compartments and the closing appliances in an emergency such as flooding. The damage control booklet is for the use of the officers.
✗
Question 20. The second officer drafts the quarterly drill plan: "muster monthly, brief on the equipment, everyone to the station, no boat actually lowered." Measured against the SOLAS chapter III drill frequencies, what is missing?
Your Answer: (Not answered)
Correct Answer: A (every lifeboat should be launched with its assigned crew at intervals not exceeding 3 months and manoeuvred with them, and launched with at least two crew at intervals not exceeding 6 months)
💡 The frequencies are easy to mix up: launching with the assigned crew and manoeuvring at intervals within 3 months, launching with two or more crew within 6 months. The monthly abandon-ship and fire drill is a separate layer and neither substitutes for the other, and an annual survey of the appliances says nothing about the crew's ability to get the boat down.
✗
Question 21. What arrangement does SOLAS require between the steering gear compartment and the navigation bridge?
Your Answer: (Not answered)
Correct Answer: C (Means of communication between the two, with provision for emergency stopping of the machinery from the steering gear compartment)
💡 SOLAS requires reliable communication between the steering gear compartment and the bridge, with provision for emergency action from the steering gear compartment, so that orders and feedback flow freely during emergency steering.
✗
Question 22. What oxygen level is normally required before entering an enclosed space?
Your Answer: (Not answered)
Correct Answer: B (Between 19.5 and 23 per cent by volume)
💡 The oxygen content in an enclosed space should be between 19.5 and 23 per cent before entry. Below 19.5 per cent there is a risk of asphyxiation; above 23 per cent the risk of combustion and explosion increases. Both departures are unsafe.
✗
Question 23. What shall fuel oil tank level gauging comply with?
Your Answer: (Not answered)
Correct Answer: A (Devices that do not endanger fire safety)
💡 Gauging shall not endanger fire safety; glass tube gauges are prohibited for such use.
✗
Question 24. What should a maintenance programme for radio equipment include?
Your Answer: (Not answered)
Correct Answer: B (Daily checks, periodic tests, spares provision and repair arrangements, either ashore or on board)
💡 SOLAS requires the availability of radio equipment to be ensured by daily checks, periodic tests, spare parts and either a shore-based maintenance agreement or at-sea maintenance capability, with the maintenance programme reflecting these arrangements and verified at survey.
✗
Question 25. Besides the emergency duties of each crew member, what else must the muster list specify?
Your Answer: (Not answered)
Correct Answer: B (The muster stations)
💡 SOLAS III/37: the muster list shall specify duties and muster stations.
✗
Question 26. What does the shipboard oil pollution emergency plan have the crew exercise in?
Your Answer: (Not answered)
Correct Answer: A (the alarm and the report when oil is seen, getting the gear out, working the containment and recovery, and who is to be told and what is said to them)
💡 The plan has to set out each step as the ship would take it: who sees it and when, how the source and position of the spill are judged, the order of raising the alarm and telling the bridge, the muster and the split of duties, what valves and pumps are worked on deck, where the boom and the absorbents live and who handles them, how the spread is held and the oil gathered, and then the report to the company, to the coastal State and to the port, its form and its timing, contact with the salvors and with other ships, the writing up and the look back afterwards. It is the exercise that puts these in the crew's hands: once a man has carried the gear and sent a practice report he knows what his own ship, at her speed and with her arrangement, can actually do. Exercises go best alongside the other drills and at the intervals the plan names, and what they show comes back into the plan and the training. A signature with no exercise, or another drill's record standing in for it, will not hold when the inspection asks or when the oil is on the water.
✗
Question 27. What is the purpose and requirement of quick-closing valves on fuel oil tanks?
Your Answer: (Not answered)
Correct Answer: C (To cut off the fuel supply rapidly from a safe position in the event of fire, operable from outside the protected space)
💡 Under SOLAS II-2/4 quick-closing valves on fuel oil tanks should be capable of rapidly cutting off the fuel supply from a safe position outside the space in the event of a fire in the machinery space, preventing the fire from spreading. The remote or quick-closing function should be tested regularly and kept effective.
✗
Question 28. How should suggestions from the crew be adopted and fed back?
Your Answer: (Not answered)
Correct Answer: B (Reasonable suggestions should be adopted and the outcome fed back to the person who raised them, encouraging participation)
💡 The ISM system encourages the crew to take part in safety management. Reasonable suggestions should be assessed and adopted, with the outcome communicated to the person who raised them, so that the crew sees the value of participating and a virtuous circle of finding and improving develops.
✗
Question 29. What does SOLAS II-2 require where the length of an enclosed corridor in accommodation spaces exceeds a certain figure?
Your Answer: (Not answered)
Correct Answer: A (A corridor exceeding 13 m must have access to escape routes at both ends)
💡 SOLAS II-2/13 requires an enclosed corridor longer than 13 m to give access to escape routes at both ends, so that occupants are not trapped in a dead end.
✗
Question 30. Where an enclosed means of escape is provided from a category A machinery space, what minimum fire protection does SOLAS II-2/13.4.3 require?
Your Answer: (Not answered)
Correct Answer: C (A-60 class division)
💡 SOLAS II-2/13.4.3 requires the enclosed means of escape from a category A machinery space to be of A-60 standard so that the route remains usable during a machinery space fire.
✗
Question 31. The main functions of an Inmarsat ship earth station include:
Your Answer: (Not answered)
Correct Answer: C (distress alerting, communication and reception of maritime safety information)
💡 SOLAS IV/7 requires an Inmarsat ship earth station for distress alerting, communication and reception of MSI.
✗
Question 32. What does SOLAS and the Polar Code require regarding manning and training for polar waters?
Your Answer: (Not answered)
Correct Answer: A (The master and officers in charge of a navigational watch must have completed appropriate polar waters training and gained the required experience)
💡 SOLAS XIV and STCW require the master and officers in charge of a navigational watch of a ship in polar waters to have completed polar waters training appropriate to the ship's category and to have the prescribed seagoing experience, ensuring the ability to operate in polar conditions.
✗
Question 33. After a fixed gas system is released, what is required before entering the space?
Your Answer: (Not answered)
Correct Answer: A (Sufficient time for the fire to be extinguished and the gas to disperse, then ventilation and testing before entry)
💡 SOLAS and the related guidance require a sufficient period after release for the fire to be extinguished and the gas to disperse, followed by ventilation and testing of the atmosphere before entry. Immediate entry risks asphyxiation or poisoning by residual gas.
✗
Question 34. What is the principle of zoning for a fixed fire detection and fire alarm system?
Your Answer: (Not answered)
Correct Answer: A (The system should detect by zone and indicate the affected zone so that the fire can be quickly located and action taken)
💡 Under SOLAS II-2/7 a fixed fire detection and fire alarm system should be arranged in sections so that the alarm indicates the section in which a fire or fault has occurred, enabling the crew quickly to locate the fire and take action. A fault in the detection system should be capable of being indicated, isolated and reset.
✗
Question 35. What does the Polar Code address regarding communication and navigation in polar waters?
Your Answer: (Not answered)
Correct Answer: A (Recognise that satellite coverage and the magnetic compass may be limited, and take measures to maintain communication and position fixing)
💡 The Polar Code requires account to be taken of limited satellite communication coverage in high latitudes, beyond geostationary satellite coverage, and the unreliability of the magnetic compass, with appropriate means such as HF and back-up navigation provided to maintain communication and position fixing in polar waters.
✗
Question 36. A watertight door is found unable to be closed remotely from the bridge. The finding is?
Your Answer: (Not answered)
Correct Answer: A (Watertight doors must be remotely closable with indication of their open or closed position; failure affects subdivision integrity)
💡 Where subdivision requires it a watertight door, especially a remotely controlled one, must be capable of remote closure from the central control station on the bridge with position indication there. Loss of remote control affects the ability to close doors rapidly and maintain subdivision integrity in the event of flooding. It is a deficiency to be corrected.
✗
Question 37. Annual verification of a Document of Compliance shall be carried out:
Your Answer: (Not answered)
Correct Answer: C (within the prescribed period around each anniversary date)
💡 SOLAS IX/4 (ISM) requires annual verification within the prescribed window around the anniversary date.
✗
Question 38. What should the cargo securing manual specify regarding maintenance of securing equipment?
Your Answer: (Not answered)
Correct Answer: C (The inspection intervals, rejection criteria and record requirements for securing equipment)
💡 SOLAS and the CSS Code require the cargo securing manual to include requirements for the inspection and maintenance of securing equipment, specifying the intervals, rejection criteria such as limits of wear, corrosion and deformation and the records to be kept, enabling the crew to judge whether an item is serviceable and to replace it promptly.
✗
Question 39. Ships of 3 000 GT and above shall be fitted with:
Your Answer: (Not answered)
Correct Answer: C (two radars, at least one of which shall be 9 GHz)
💡 SOLAS V/19: ships of 3 000 GT and above shall be fitted with two radars, at least one of which shall be 9 GHz.
✗
Question 40. What does SOLAS address regarding the arrangement of lubricating oil systems in machinery spaces?
Your Answer: (Not answered)
Correct Answer: C (Piping must be leak-tight and kept away from hot surfaces, with level monitoring of oil tanks)
💡 SOLAS requires lubricating oil piping to be leak-tight and clear of hot surfaces, with level monitoring of the oil tanks. Oil leaking onto a hot surface or a turbine is a common cause of machinery space fires.
✗
Question 41. The whistle is found inoperative or the sound signalling appliance has failed. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Failure of the sound signalling appliance affects collision avoidance and navigation in fog, a deficiency to be corrected)
💡 The whistle and sound signalling appliance are used to give the prescribed signals in fog, in narrow channels and when coordinating with other ships, being important means of collision avoidance and safe navigation. Failure prevents the ship from giving the required sound signals and increases the risk of collision. It is a deficiency to be corrected.
✗
Question 42. What is the usual weekly running requirement for a lifeboat engine?
Your Answer: (Not answered)
Correct Answer: D (Run at least once each week for not less than the prescribed period, normally three minutes or more)
💡 SOLAS requires the lifeboat engine to be run at least once each week for not less than the prescribed time, bringing it to normal operating condition. Annual testing alone does not ensure the engine will start in an abandonment.
✗
Question 43. What monitoring of moisture content is required for cargoes liable to liquefy?
Your Answer: (Not answered)
Correct Answer: B (Confirm the moisture content is below the transportable moisture limit before loading and guard against rain increasing it during loading)
💡 The IMSBC Code requires confirmation that the moisture content is below the TML before loading, normally from a certificate or test report, with attention during loading to rain, changes in the moisture of the cargo and water in the hold, preventing the content rising above the TML and liquefaction at sea.
✗
Question 44. What does SOLAS XI-1/7 require regarding asbestos?
Your Answer: (Not answered)
Correct Answer: A (Installation of materials containing asbestos on new equipment is prohibited, and a declaration or certificate of no asbestos must be held)
💡 SOLAS XI-1/7 prohibits the installation of materials containing asbestos on all ships and requires a declaration or certificate of no asbestos, protecting seafarers from the health hazard.
✗
Question 45. What is the cycle for safety management system audits?
Your Answer: (Not answered)
Correct Answer: D (Internal audits normally not exceeding 12 months, annual verification of the DOC and intermediate verification of the SMC)
💡 The ISM Code requires internal audits at intervals not exceeding 12 months, annual verification of the Document of Compliance to keep it valid and intermediate verification of the Safety Management Certificate within its period of validity. Failure to verify in time affects the validity of the certificates.
✗
Question 46. What electrical equipment is required in a pump room on a tanker?
Your Answer: (Not answered)
Correct Answer: B (Explosion-protected equipment, with the number of items and wiring minimised)
💡 A pump room is a high-risk space where hydrocarbon vapour can accumulate. SOLAS and the IBC Code require explosion-protected equipment with the number of items and wiring kept to a minimum, preventing electrical sparks from igniting vapour.
✗
Question 47. What is required for testing the emergency lighting system?
Your Answer: (Not answered)
Correct Answer: A (Periodic testing of automatic operation and duration, with records kept)
💡 SOLAS and good practice require periodic testing of the automatic operation of the emergency lighting and of its duration, for example by simulating failure of the main source, observing the lighting come on and timing it, verifying the prescribed period with records kept, preventing failure during an actual blackout.
✗
Question 48. What does SOLAS address regarding electrical equipment in a paint locker?
Your Answer: (Not answered)
Correct Answer: C (Explosion-protected equipment or no electrical equipment within the space)
💡 SOLAS requires explosion-protected equipment in a paint locker, or no electrical equipment inside it, such as lighting fitted outside, preventing an electrical spark from igniting paint vapour.
✗
Question 49. What is required in managing the rectification of deficiencies found at an inspection?
Your Answer: (Not answered)
Correct Answer: C (Prepare a plan with responsibilities and deadlines, follow it through and keep evidence of the rectification)
💡 After deficiencies are found a rectification plan should be prepared with the measures, the persons responsible and deadlines, followed through to closure with evidence kept, such as repair records, photographs and survey reports, and fed back to the company, the flag State or the port State as required, preventing the recurrence of the same deficiency.
✗
Question 50. What does SOLAS V and STCW require regarding the arrangement of navigational watches?
Your Answer: (Not answered)
Correct Answer: B (Watch arrangements must ensure that personnel are not impaired by fatigue in carrying out their duties)
💡 SOLAS V/34 and STCW require watch schedules that prevent fatigue from impairing the performance of duties, with prescribed minimum rest hours. Fatigue management is continuous, not a night-time concern only.
✗
Question 51. Insulation was removed from a fire division for work and not replaced. What is the finding?
Your Answer: (Not answered)
Correct Answer: B (A deficiency; missing insulation reduces the fire performance of the division and must be restored promptly)
💡 Insulation removed from a fire division, for example to gain access during work, and not replaced significantly reduces its fire performance, so heat and fire cannot be effectively contained. It is a deficiency affecting safety and must be restored promptly with approved material.
✗
Question 52. What is the minimum number of radar transponders (SARTs) for a cargo ship of 500 gross tonnage and above?
Your Answer: (Not answered)
Correct Answer: D (Two, one on each side)
💡 Under SOLAS IV/7 a cargo ship of five hundred gross tonnage and above should carry at least two radar transponders, normally one on each side, so that one can be taken into the survival craft on either side during abandonment. The SART marks the distress position on the radar.
✗
Question 53. What type of seal is required for cable penetrations of a fire division?
Your Answer: (Not answered)
Correct Answer: D (An approved penetration seal whose fire rating is not less than the division penetrated)
💡 SOLAS requires cable penetration seals to be approved with a fire rating not less than that of the division penetrated, for example an A-60 rated seal where an A-60 division is crossed. Ordinary packing or expanding foam does not meet the fire and smoke requirements.
✗
Question 54. What is the primary function of a satellite EPIRB?
Your Answer: (Not answered)
Correct Answer: D (To alert the shore and provide the distress position)
💡 On activation the EPIRB alerts a rescue centre and provides the distress position.
✗
Question 55. What does SOLAS emphasise in the launching and recovery of survival craft?
Your Answer: (Not answered)
Correct Answer: A (Operations must be carried out under safe conditions with adequate lighting and by persons familiar with the procedure)
💡 SOLAS requires launching and recovery to be conducted under safe conditions, with adequate lighting, by persons familiar with the procedure and equipment, to avoid casualties during drills.
✗
Question 56. What is required of navigational equipment fitted on board?
Your Answer: (Not answered)
Correct Answer: B (That it complies with the applicable standards and remains in effective working order)
💡 It shall comply with applicable standards and remain in effective working order.
✗
Question 57. What information must drill records contain under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (The date, the type and scenario of the drill, the craft and equipment used, the persons taking part and any defects found)
💡 SOLAS requires drill records to include the date, the scenario, the craft and equipment used, the persons taking part and any problems found with the action taken, enabling a surveyor to judge whether the drills were genuine and effective.
✗
Question 58. The Ship Security Plan shall be approved by:
Your Answer: (Not answered)
Correct Answer: A (the Administration or a recognised security organisation on its behalf)
💡 SOLAS XI-2/3: the Ship Security Plan shall be approved by the Administration or a recognised security organisation on its behalf.
✗
Question 59. The self-contained breathing apparatus in a firefighter's outfit shall be capable of being used for at least:
Your Answer: (Not answered)
Correct Answer: C (30 minutes)
💡 SOLAS II-2/10: the self-contained breathing apparatus in a firefighter's outfit shall be capable of being used for at least 30 minutes.
✗
Question 60. Water-tight doors shall be capable of being operated watertight:
Your Answer: (Not answered)
Correct Answer: D (At all times)
💡 Water-tight doors must be capable of being closed watertight at all times and kept closed during navigation.
✗
Question 61. What safety requirements apply to steam systems?
Your Answer: (Not answered)
Correct Answer: A (Insulation and marking of piping and valves, with safety valves and drains, preventing burns and overpressure)
💡 SOLAS and good practice require steam piping to be insulated and marked for temperature and steam valves and fittings to have safety valves and drains, preventing burns, overpressure and water hammer damage. Steam systems are hazardous and must be operated strictly under the procedure.
✗
Question 62. What does SOLAS V and STCW require regarding watchkeeping when a ship is at anchor?
Your Answer: (Not answered)
Correct Answer: C (A proper anchor watch must be maintained, keeping continuous watch on the ship's position, weather and nearby traffic)
💡 Anchoring does not end watchkeeping duties. SOLAS and STCW require a proper anchor watch, monitoring position, weather changes and the risk of dragging, and taking timely action.
✗
Question 63. What is the requirement for the total capacity of fire pumps?
Your Answer: (Not answered)
Correct Answer: A (It shall be sufficient to supply the required jets at the minimum pressure)
💡 Pumps shall supply the required jets at the prescribed minimum pressure.
✗
Question 64. What do SOLAS and the IMDG Code require for marking and labelling of dangerous goods packages?
Your Answer: (Not answered)
Correct Answer: D (The proper shipping name, UN number and the relevant hazard class label)
💡 SOLAS VII and the IMDG Code require dangerous goods packages to show the proper shipping name, the UN number and the relevant hazard class label, including the marine pollutant mark, so that the crew can identify the hazard and act accordingly.
✗
Question 65. What fire rating does SOLAS normally require for the boundaries of main vertical zones?
Your Answer: (Not answered)
Correct Answer: B (A-60 class)
💡 SOLAS requires the boundaries between main vertical zones to be class A-60 divisions, confining a fire to the zone in which it starts and preventing spread to adjacent zones.
✗
Question 66. How must a ship fulfil the duty to render assistance at sea under SOLAS V?
Your Answer: (Not answered)
Correct Answer: A (To proceed with all speed to render assistance where there is reasonable ground to believe another ship is in distress, and to inform the owner or agent)
💡 SOLAS requires the master to proceed with all speed to render assistance where there is reasonable ground to believe a ship is in distress, and to inform the owner or agent. Assistance is a legal duty.
✗
Question 67. What does the Polar Code address regarding safety equipment for ships in polar waters?
Your Answer: (Not answered)
Correct Answer: B (Equipment suited to the polar environment for life-saving, firefighting, ice protection and emergencies)
💡 The Polar Code requires equipment suited to the polar environment, such as thermally protective life-saving appliances, firefighting equipment suitable for low temperature, ice protection and de-icing arrangements and emergency communication and escape means. Ordinary water equipment is not sufficient.
✗
Question 68. What are the key points in simulating search and rescue in a fire drill?
Your Answer: (Not answered)
Correct Answer: B (Practise donning breathing apparatus, entering with firefighter's equipment to search and moving casualties)
💡 A fire drill should include simulated entry for search and rescue: donning breathing apparatus, taking the axe and safety lamp, using a hose for protection and searching for and moving casualties, so that the crew acquires the skills needed in a smoke filled environment.
✗
Question 69. What is the scope of application of the ISPS Code?
Your Answer: (Not answered)
Correct Answer: D (Ships of 500 GT and above engaged on international voyages and the port facilities serving them)
💡 SOLAS XI-2 and the ISPS Code apply to ships of 500 GT and above on international voyages and to the port facilities serving such ships, not to all ships.
✗
Question 70. In preparing a voyage plan, consideration shall be given to:
Your Answer: (Not answered)
Correct Answer: D (navigational hazards, safe speed, collision avoidance and contingency measures)
💡 SOLAS V/34 requires the voyage plan to consider navigational hazards, safe speed, avoidance and contingency measures.
✗
Question 71. From what source must emergency lighting in accommodation spaces and escape routes be supplied?
Your Answer: (Not answered)
Correct Answer: C (From the emergency source, automatically connected when the main source fails)
💡 SOLAS requires emergency lighting in escape routes and accommodation to be supplied from the emergency source and connected automatically when the main source fails, without manual switching. Main source supply would not illuminate when power is lost.
✗
Question 72. What does the ISM Code address regarding evaluation of the effectiveness of the safety management system?
Your Answer: (Not answered)
Correct Answer: D (Evaluating whether the elements of the system are effectively implemented, through audits and reviews, and identifying opportunities for improvement)
💡 ISM Code 3 requires the company to evaluate the effectiveness of the elements of the safety management system through internal and external audits and management review, identifying problems and opportunities for improvement and taking action, keeping the system suitable and effective.
✗
Question 73. With regard to charts, which requirement is correct?
Your Answer: (Not answered)
Correct Answer: A (up-to-date charts covering the intended voyage shall be carried)
💡 SOLAS V/27 requires up-to-date charts covering the intended voyage.
✗
Question 74. The weekly inspection of launching appliances shall include checking:
Your Answer: (Not answered)
Correct Answer: D (the davits, falls and brakes for proper condition)
💡 SOLAS III/20 requires weekly inspection of davits, falls and brakes.
✗
Question 75. What should be done with a fire hose after use?
Your Answer: (Not answered)
Correct Answer: A (Clean and dry it, then roll and stow it in the proper manner in place, keeping it ready for use)
💡 After use a fire hose should be washed free of oil and salt water, dried and then rolled and stowed in the proper manner in its position, preventing rot and ageing which affect pressure resistance. Stowing it damp or exposing it long term shortens its life.
✗
Question 76. A 120 m cargo ship has one lifeboat on each side. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (The capacity on each side must accommodate all persons, with at least one boat serving as a rescue boat)
💡 SOLAS requires the capacity on each side of a cargo ship to accommodate all persons on board, with at least one boat meeting the rescue boat requirements. Counting the two boats together would not ensure escape if one side were lost.
✗
Question 77. What is the scope of SOLAS II-1?
Your Answer: (Not answered)
Correct Answer: A (Construction of ships to which the Convention applies, including subdivision, stability and machinery and electrical installations)
💡 SOLAS II-1 covers construction including subdivision, stability and machinery and electrical installations. Fire protection is Chapter II-2 and life-saving appliances Chapter III.
✗
Question 78. What is required regarding correction of charts and publications?
Your Answer: (Not answered)
Correct Answer: B (They shall be kept corrected up to date)
💡 They shall be kept corrected up to date.
✗
Question 79. What is the principal method of structural fire protection in accommodation and service spaces under SOLAS II-2?
Your Answer: (Not answered)
Correct Answer: B (Division into main vertical zones by class A and B divisions to limit fire spread)
💡 SOLAS II-2 protects accommodation and service spaces principally by fire-resisting divisions into main vertical zones with class A and B boundaries, rather than by extinguishing or detection equipment alone.
✗
Question 80. What steering gear checks should be made before navigating in confined waters?
Your Answer: (Not answered)
Correct Answer: C (Check the steering gear alarms, test rudder movement and the rudder angle indicator and confirm the power and control systems are in order)
💡 Before navigating in confined waters such as a narrow channel or when berthing, the steering gear should be tested, the rudder angle indicator checked and the alarms and the power and control systems verified. A sudden steering failure in confined waters has serious consequences.
✗
Question 81. During a PSC inspection the emergency fire pump discharge pressure is found below the rated value. Which finding is most likely?
Your Answer: (Not answered)
Correct Answer: A (The firefighting equipment is not capable of working effectively, a serious deficiency that may lead to detention)
💡 The emergency fire pump is a core item of the firefighting system and its capacity and pressure must meet the required values. A measured pressure below the rated value shows that the emergency firefighting capability cannot function effectively. This is a key deficiency affecting the safety of the ship, normally recorded as a detainable deficiency to be rectified before departure.
✗
Question 82. What is the purpose of the automatic radar plotting aid required on board?
Your Answer: (Not answered)
Correct Answer: C (To track targets automatically and compute their course, speed, closest point of approach and time to CPA, assisting collision avoidance)
💡 ARPA tracks radar targets automatically and provides their course, speed, closest point of approach and time to CPA, assisting the officer in judging the risk of collision. It does not replace his judgement or the avoiding action.
✗
Question 83. What is required for coordinating mooring lines and tugs when unberthing?
Your Answer: (Not answered)
Correct Answer: D (Slack and let go the lines in the proper order while maintaining communication with tugs and the terminal, preventing lines from fouling the propeller)
💡 Lines should be let go in the proper order, normally the spring and breast lines first and the head and stern lines last, with communication maintained with the tugs and the terminal, preventing slack lines from being taken into the propeller and damaging the propulsion system.
✗
Question 84. A rescue boat shall be provided with equipment including:
Your Answer: (Not answered)
Correct Answer: B (a complete set including oars, lifebuoy, first-aid kit and searchlight)
💡 SOLAS III/34 (LSA Code) requires a rescue boat to carry equipment including oars, lifebuoy, first-aid kit and searchlight.
✗
Question 85. The emergency steering position shall be located:
Your Answer: (Not answered)
Correct Answer: B (in the steering gear compartment)
💡 SOLAS V/13: the emergency steering position shall be located in the steering gear compartment.
✗
Question 86. At what angle of list must lifeboat launching appliances still operate?
Your Answer: (Not answered)
Correct Answer: A (A list of up to 20 degrees to either side)
💡 SOLAS requires launching appliances to be capable of operation with the ship listed up to 20 degrees either way. Free-fall lifeboats have additional conditions such as trim by the stern.
✗
Question 87. What accuracy requirement applies to electronic position fixing systems?
Your Answer: (Not answered)
Correct Answer: A (They must provide the accuracy needed for safe navigation and give an indication when accuracy degrades)
💡 SOLAS requires electronic position fixing systems to provide the accuracy needed for safe navigation and to warn the user when accuracy degrades, such as a GPS integrity alarm, so the officer can switch to other means.
✗
Question 88. What certificate must a ship operating in polar waters carry?
Your Answer: (Not answered)
Correct Answer: C (A Polar Ship Certificate)
💡 SOLAS XIV/3 requires ships operating in polar waters to hold a Polar Ship Certificate attesting compliance with the relevant parts of the Polar Code.
✗
Question 89. The steering gear takes 35 seconds to move the rudder from 35 degrees one side to 30 degrees the other. What is the finding?
Your Answer: (Not answered)
Correct Answer: B (It exceeds the prescribed 28 seconds and does not comply; the steering gear performance must be investigated)
💡 SOLAS II-1/29 requires the main steering gear, at maximum service speed and deepest seagoing draught, to complete the movement from 35 degrees one side to 30 degrees the other within 28 seconds. Thirty five seconds exceeds the limit and indicates a problem with the power or control capability of the steering gear.
✗
Question 90. What action do SOLAS and STCW require if the main engine fails while under way?
Your Answer: (Not answered)
Correct Answer: A (Notify the bridge immediately, display the appropriate lights, shapes or sound signals and take action such as anchoring or other avoidance measures)
💡 Engine failure deprives the ship of manoeuvrability. The bridge must be informed at once, the lights, shapes or signals for a vessel not under command displayed, and measures such as anchoring taken to avoid collision, with the authorities informed.
✗
Question 91. During a PSC inspection the firefighter's outfits were checked. Under SOLAS II-2/10.1, which of the following is NOT part of a firefighter's outfit?
Your Answer: (Not answered)
Correct Answer: D (A portable gas detector)
💡 SOLAS II-2/10.1 defines a firefighter's outfit as personal equipment (protective clothing, boots and gloves, rigid helmet, electric safety lamp and axe) together with a self-contained compressed air breathing apparatus. A gas detector belongs to other requirements such as enclosed space entry and is not part of the outfit.
✗
Question 92. A cargo ship of 4200 GT on an international voyage. How many independently driven fire pumps are required as a minimum?
Your Answer: (Not answered)
Correct Answer: C (Two)
💡 SOLAS II-2/10.2: cargo ships of 1000 GT and above shall have at least two independently driven fire pumps.
✗
Question 93. What does SOLAS address regarding separation between the cargo area and machinery space of a tanker?
Your Answer: (Not answered)
Correct Answer: B (A-60 class separation between the cargo tank area and category A machinery spaces, preventing passage of vapour and fire)
💡 SOLAS requires A-60 class separation between the cargo tank area and category A machinery spaces of a tanker, preventing vapour from entering the machinery space or fire spreading from it into the cargo area with far greater consequences.
✗
Question 94. What is the minimum rest requirement for a crew member in any 24-hour period?
Your Answer: (Not answered)
Correct Answer: A (At least ten hours)
💡 Under STCW and the related requirements of the Maritime Labour Convention 2006, a crew member must have at least ten hours of rest in any twenty-four hour period, which may be divided into not more than two periods one of which is at least six hours, with at least seventy-seven hours of rest in any seven-day period.
✗
Question 95. What preparation and checks are required before entering port?
Your Answer: (Not answered)
Correct Answer: D (Test the main engine and steering gear, check the telegraph, verify draught and under-keel clearance and confirm certificates and documents are in order)
💡 Before entering port the main engine and steering gear should be tested, the telegraph checked, the windlass and thrusters where fitted examined, the draught and under-keel clearance verified and the nautical publications corrected and certificates ready, so that the ship is fully under control in confined waters.
✗
Question 96. How many rocket parachute flares must each survival craft carry?
Your Answer: (Not answered)
Correct Answer: A (4)
💡 SOLAS III/7.1 requires four rocket parachute flares in each survival craft. Six is the usual number for hand flares, which is easily confused with this.
✗
Question 97. When may the Administration withdraw a certificate?
Your Answer: (Not answered)
Correct Answer: D (When the ship's condition does not correspond substantially with the certificate and remains uncorrected)
💡 When the condition of the ship does not correspond substantially with the certificate.
✗
Question 98. What does SOLAS address regarding lighting and marking of emergency escape routes from machinery spaces?
Your Answer: (Not answered)
Correct Answer: B (Emergency lighting and clear marking enabling the direction to be identified even in dense smoke)
💡 SOLAS requires escape routes from machinery spaces to have emergency lighting and clear low level marking identifiable in dense smoke, so that personnel can find the exit when visibility is very poor. Ordinary stickers or daylight-only marking do not comply.
✗
Question 99. Lifeboat and liferaft launching appliances shall be capable of operating when the ship is listed by:
Your Answer: (Not answered)
Correct Answer: C (not more than 20°)
💡 SOLAS III/16 requires launching appliances to operate with the ship listed up to 20°.
✗
Question 100. What is required of drinking water containers in survival craft?
Your Answer: (Not answered)
Correct Answer: D (Hygienic containers preventing contamination, with the water renewed as prescribed)
💡 SOLAS requires survival craft to have hygienic containers for fresh water, preventing contamination and deterioration, with the water renewed at the prescribed servicing intervals. Water not renewed for a long time becomes undrinkable and affects survival.