Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. What protection is required when taking shore power in port?
Your Answer: (Not answered)
Correct Answer: A (Confirm voltage, frequency and phase sequence match, with insulation checked and proper earthing, preventing damage and electric shock)
💡 Before taking shore power, the voltage, frequency and phase sequence should be confirmed to match, with the cable insulation checked, reliable earthing established and earth leakage protection fitted. Once connected, the phase sequence should be verified to prevent motors running backwards and the equipment confirmed to operate normally, preventing damage and electric shock.
✗
Question 2. When peak and deep tanks are used as ballast tanks, what does SOLAS II-1 require of the ballast system?
Your Answer: (Not answered)
Correct Answer: B (It must be capable of safely filling and emptying ballast tanks under all operating conditions)
💡 SOLAS II-1 requires the ballast system to fill and empty tanks safely under all operating conditions so that draught and stability can be controlled. It is not confined to port use.
✗
Question 3. What routine maintenance does the fire main require?
Your Answer: (Not answered)
Correct Answer: A (Periodic checks for corrosion and leakage, freedom of valve operation and prevention of water standing and freezing in the pipe)
💡 The fire main should be checked periodically for corrosion and leakage of the pipe wall and for freedom of valve operation, with standing water prevented from freezing in cold weather and periodic pressure testing, ensuring the system works reliably when needed.
✗
Question 4. What shall fuel oil tank level gauging comply with?
Your Answer: (Not answered)
Correct Answer: A (Devices that do not endanger fire safety)
💡 Gauging shall not endanger fire safety; glass tube gauges are prohibited for such use.
✗
Question 5. A ship was detained by PSC and, after rectification, released following re-inspection by a recognised organisation. Under SOLAS, who issues the relevant certificate?
Your Answer: (Not answered)
Correct Answer: C (The Administration or a person duly authorised by it)
💡 The power to issue certificates rests with the Administration. A recognised organisation may act only within the scope of a formal authorisation given by that Administration.
✗
Question 6. The Polar Water Operational Manual (PWOM) is intended to:
Your Answer: (Not answered)
Correct Answer: A (provide the ship's operational limitations and procedures for operating in polar waters)
💡 SOLAS XIV/2: the Polar Water Operational Manual provides the ship's operational limitations and procedures for operating in polar waters.
✗
Question 7. What are the requirements for the position of the satellite EPIRB on board?
Your Answer: (Not answered)
Correct Answer: C (Readily accessible, capable of floating free and activating automatically if the ship sinks)
💡 SOLAS requires the EPIRB to be mounted where it is readily accessible manually, will float free and activate automatically if the ship sinks. Keeping it locked in a room or drawer does not comply.
✗
Question 8. Which extinguisher is least suitable for a galley cooking oil fire?
Your Answer: (Not answered)
Correct Answer: C (Direct water jets)
💡 Water on a fat fire causes splashing and reignition; a blanket or fat-fire agent must be used.
✗
Question 9. When an oil pollution incident occurs at sea, besides taking control and clean-up measures, what should be done?
Your Answer: (Not answered)
Correct Answer: B (Report to the Administration and those concerned under the Shipboard Oil Pollution Emergency Plan and record the incident and cooperate with the clean-up)
💡 When an oil pollution incident occurs, control, clean-up and reporting measures should be taken under the Shipboard Oil Pollution Emergency Plan, the incident reported to the flag State, coastal State and those concerned, records kept and the authorities' clean-up and investigation cooperated with. Concealing or delaying a report aggravates liability and hinders response.
✗
Question 10. Class A and class B divisions: what separates them?
Your Answer: (Not answered)
Correct Answer: A (class A of steel or equivalent with non-combustible insulation, stopping flame and smoke; class B need only be non-combustible and for a shorter time)
💡 Three things decide the class: the material, the limit on temperature rise on the unexposed face, and the time the division stands up to the standard fire test. Class A asks for steel or equivalent material with non-combustible insulation behind, so that neither flame nor smoke passes, and for the longest test period; class B asks only that the material be non-combustible, with lower insulation and strength and a much shorter time holding flame. Either class may be a bulkhead or a deck, the name not fixing the use; which class a boundary needs depends on how dangerous the space is, whether the ship carries passengers or cargo, and what the rules require around machinery spaces, stairways and control stations. Cut a hole for a pipe and leave it unsealed and the division stops being what it was, which is the commonest thing an inspection finds.
✗
Question 11. What does SOLAS require of the water ingress detection and alarm system on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: B (Detection in cargo holds, ballast tanks and dry spaces, with an audible and visual alarm on the bridge)
💡 SOLAS XII/12 requires a bulk carrier to have water ingress detection in cargo holds, ballast tanks and dry spaces, with an audible and visual alarm on the bridge, enabling the watchkeeper to detect flooding promptly and act.
✗
Question 12. Where a certificate expires and the ship is not in a port of survey, the Administration may extend the certificate for a period not exceeding:
Your Answer: (Not answered)
Correct Answer: A (5 months)
💡 SOLAS I/14: where a ship is not in a port of survey at expiry, the Administration may extend the certificate for a period not exceeding 5 months.
✗
Question 13. A section of the fire detection system fails to alarm during testing. What should be done?
Your Answer: (Not answered)
Correct Answer: C (Establish the cause at once, such as a failed detector, broken wiring or incorrect zoning, and repair it)
💡 A section that does not alarm means a fire there would not be detected in time. The cause must be established at once, whether a failed detector, broken wiring, incorrect zoning or an inhibited circuit, and repaired. Disabling the section or relying on another leaves a serious latent hazard.
✗
Question 14. Which statement about the use of weather routeing is correct?
Your Answer: (Not answered)
Correct Answer: D (The route should be chosen taking account of weather forecasts and the ship's condition, avoiding severe weather and monitoring the passage plan)
💡 Weather routeing should combine professional weather forecasts with the ship's condition, such as stability, cargo and draught, to choose a relatively safe route avoiding typhoons, heavy seas and severe weather, monitoring and adjusting the plan during the voyage. It is an aid, the final navigational decision being the master's responsibility.
✗
Question 15. A Polar Ship Certificate shall state:
Your Answer: (Not answered)
Correct Answer: A (the ship's operational limitations in polar waters, such as ice class and temperature range)
💡 SOLAS XIV/2: a Polar Ship Certificate states the ship's operational limitations in polar waters, such as ice class and temperature range.
✗
Question 16. What is required for checking the windlass and anchor cable?
Your Answer: (Not answered)
Correct Answer: A (Periodic checks of the windlass brake and clutch and the wear of the cable, ensuring reliable anchoring)
💡 The windlass brake and clutch and the anchor cable with its stopper should be checked periodically for wear and corrosion, ensuring reliable operation when anchoring is needed in an emergency. A failed windlass deprives the ship of her last resort at a critical moment, particularly in confined waters.
✗
Question 17. What determines the number of fireman's outfits to be carried?
Your Answer: (Not answered)
Correct Answer: A (The gross tonnage)
💡 The number of fireman's outfits is determined by the gross tonnage.
✗
Question 18. A fire hose is found with perished and cracked lining. What should be done?
Your Answer: (Not answered)
Correct Answer: C (Replace it at once; a cracked and perished hose will burst under pressure and cannot be used)
💡 A hose lining that is perished and cracked will burst or leak under working pressure and cannot extinguish a fire effectively, so it should be replaced at once. Repair with tape or other means does not meet the pressure requirement, and keeping it is a deficiency affecting firefighting capability.
✗
Question 19. What must the PWOM contain regarding operational measures for polar waters?
Your Answer: (Not answered)
Correct Answer: A (Ice assessment in voyage planning, ship capability limitations, emergency procedures and training requirements)
💡 The Polar Water Operational Manual must cover voyage planning, ice assessment, the ship's ice class capabilities and limitations, operation of equipment in low temperature, emergency procedures and training, guiding the master's decisions in ice.
✗
Question 20. What does SOLAS address regarding the watertight integrity of spaces above the bulkhead deck?
Your Answer: (Not answered)
Correct Answer: C (Openings must be fitted with effective closing appliances to prevent sea water entering the hull through them)
💡 SOLAS requires openings such as doors, side scuttles and ventilators above the bulkhead deck to have effective closing appliances, preventing sea water from entering the hull and causing loss of stability.
✗
Question 21. Who must confirm the securing arrangement for cargo units under SOLAS and the CSS Code?
Your Answer: (Not answered)
Correct Answer: A (The master or chief officer, in accordance with the approved cargo securing manual)
💡 SOLAS VI/5 and the CSS Code require the securing arrangement to be determined in accordance with the approved cargo securing manual and confirmed by the master or the responsible officer as to position, number and pre-tension. It is not left to the terminal or the cargo owner.
✗
Question 22. Surveys required for ships include:
Your Answer: (Not answered)
Correct Answer: C (initial, renewal, intermediate, annual and additional surveys)
💡 SOLAS I/6: surveys include initial, renewal, intermediate, annual and additional surveys.
✗
Question 23. During a PSC inspection the firefighter's outfits were checked. Under SOLAS II-2/10.1, which of the following is NOT part of a firefighter's outfit?
Your Answer: (Not answered)
Correct Answer: D (A portable gas detector)
💡 SOLAS II-2/10.1 defines a firefighter's outfit as personal equipment (protective clothing, boots and gloves, rigid helmet, electric safety lamp and axe) together with a self-contained compressed air breathing apparatus. A gas detector belongs to other requirements such as enclosed space entry and is not part of the outfit.
✗
Question 24. From where may the ventilation openings of machinery spaces be closed?
Your Answer: (Not answered)
Correct Answer: A (From outside the machinery space)
💡 SOLAS II-2/9: ventilation openings shall be capable of being closed from outside the space.
✗
Question 25. How should medical advisory services be used?
Your Answer: (Not answered)
Correct Answer: B (Contact a shore-based medical advisory service by radio or satellite for guidance when a crew member is ill or injured)
💡 SOLAS and the MLC require the ship to contact a shore-based medical advisory service such as a TMAS by radio, satellite or other means for professional guidance when needed, recording the consultation and the treatment given. Prompt advice on an ocean passage markedly improves the outcome.
✗
Question 26. What are the requirements for using a ship's call sign and identity?
Your Answer: (Not answered)
Correct Answer: C (Use the registered call sign and MMSI, never another ship's identity or an incorrect code)
💡 Ship radio communication must use the registered call sign and MMSI. Using another ship's identity or an incorrect number misleads coast stations and other ships and, in a distress, affects the location of the casualty, and is a serious breach.
✗
Question 27. Where shall inflatable liferafts be serviced?
Your Answer: (Not answered)
Correct Answer: A (At an approved servicing station)
💡 At an approved servicing station.
✗
Question 28. A valve on the fire main has seized because it has not been operated for a long time. What is the finding?
Your Answer: (Not answered)
Correct Answer: A (A deficiency; valves must remain operable, and a seized valve prevents water reaching the required area)
💡 A fire main valve left unoperated seizes, so that in a fire it cannot be opened or changed over and water cannot reach the space concerned. Valves should be operated and lubricated periodically; a seized valve is a deficiency affecting safety.
✗
Question 29. What should be noted about fog signals in restricted visibility?
Your Answer: (Not answered)
Correct Answer: A (Sound fog signals as COLREG prescribes and listen attentively to other vessels' signals to judge bearing and movement)
💡 In restricted visibility fog signals should be sounded as COLREG prescribes, for example one prolonged blast at intervals of not more than two minutes for a power-driven vessel under way, while listening carefully to other vessels' signals to judge their approximate bearing and movement, combined with radar observation. Sounding must not be delayed.
✗
Question 30. What is the basic SOLAS II-1 requirement for the position of the collision bulkhead on a cargo ship?
Your Answer: (Not answered)
Correct Answer: A (At a distance from the forward perpendicular of not less than 5 per cent of the ship's length, or 10 m, whichever is the less)
💡 SOLAS II-1 requires the collision bulkhead to be not less than 5 per cent of the ship's length or 10 m, whichever is less, from the forward perpendicular, so that flooding forward protects the spaces abaft.
✗
Question 31. How must the loading instrument of a bulk carrier be used?
Your Answer: (Not answered)
Correct Answer: B (Compute strength and stability for the planned sequence before cargo work and monitor continuously during it)
💡 SOLAS requires the approved loading instrument to be used to compute hull strength and stability at each stage of the planned sequence before cargo work, with continuous monitoring during the operation and updating as it progresses, preventing excessive stress at any stage. Computing only at the end cannot prevent damage during the work.
✗
Question 32. What certification is required for radio communication under SOLAS and STCW?
Your Answer: (Not answered)
Correct Answer: D (Persons responsible for radio communication must hold the appropriate GMDSS certificate)
💡 SOLAS and STCW require persons responsible for radio communication to hold a GMDSS certificate appropriate to the equipment fitted, graded by sea area and equipment type, such as the General Operator's Certificate and the Restricted Operator's Certificate.
✗
Question 33. What is the maximum extension the Administration may grant to an expired certificate?
Your Answer: (Not answered)
Correct Answer: B (5 months)
💡 An extension of not more than 5 months may be granted.
✗
Question 34. What overload protection is required for electrical equipment?
Your Answer: (Not answered)
Correct Answer: C (Overload protection for essential motors and cables, preventing overheating which damages insulation and causes fire)
💡 SOLAS requires overload protection for essential motors, cables and distribution equipment, operating to trip or alarm on overload, preventing prolonged overheating from ageing the insulation and causing an electrical fire, particularly in the high temperature environment of a machinery space.
✗
Question 35. What shall the radio log essentially contain?
Your Answer: (Not answered)
Correct Answer: C (Records of distress, urgency and safety communications and equipment failures)
💡 Records of distress and safety communications and equipment failures.
✗
Question 36. What is the significance of the distinction between life-saving appliances and arrangements in SOLAS Chapter III?
Your Answer: (Not answered)
Correct Answer: A (Appliances are items such as survival craft and lifejackets, while arrangements are the boarding, launching, stowage and lighting provisions)
💡 In SOLAS Chapter III, life-saving appliances are items such as craft, lifejackets and equipment, while arrangements refer to the structural provisions for boarding, launching, stowage and lighting. The two attract different points of attention at survey.
✗
Question 37. What are the stowage requirements for paint and thinners?
Your Answer: (Not answered)
Correct Answer: A (Kept in a dedicated paint locker with closed containers and ventilation, not stored in quantity with other combustibles)
💡 SOLAS requires paint and thinners to be kept in a dedicated paint locker, with containers closed and the space ventilated and provided with extinguishing arrangements. Keeping them in the machinery space or accommodation greatly increases the risk of fire and poisoning.
✗
Question 38. Which channel is used for VHF DSC distress alerting?
Your Answer: (Not answered)
Correct Answer: B (Channel 70)
💡 VHF DSC distress and calling use channel 70, which is not used for speech. Channel 16 is for radiotelephony distress and safety traffic.
✗
Question 39. What rescue arrangement is required when entering an enclosed space?
Your Answer: (Not answered)
Correct Answer: B (A standby person at the entrance with rescue equipment and continuous communication)
💡 Entry into an enclosed space requires a standby person at the entrance, continuous communication and rescue equipment including breathing apparatus, so that immediate rescue is possible. Solo entry is a principal cause of multiple fatalities.
✗
Question 40. Which of the following is NOT among the statutory certificates normally obtained by a cargo ship after the relevant surveys?
Your Answer: (Not answered)
Correct Answer: B (The International Ship Security Certificate, which is issued under the ISPS Code and Chapter XI-2)
💡 SOLAS I/7 lists the Cargo Ship Safety Construction Certificate, Safety Equipment Certificate and Safety Radio Certificate. The ISSC is issued under Chapter XI-2 and the ISPS Code and is not one of the three listed in I/7.
✗
Question 41. When clear grounds are found during a PSC inspection, what is the next step?
Your Answer: (Not answered)
Correct Answer: A (A more detailed inspection, with detention if deficiencies are serious)
💡 PSC procedures require a more detailed inspection where clear grounds exist. Detention follows only where deficiencies are clearly hazardous; PSCOs do not normally fine ships or withdraw certificates directly.
✗
Question 42. What analysis of accidents and near misses is required?
Your Answer: (Not answered)
Correct Answer: D (Report and analyse the root cause, take corrective action, assess the outcome and share the lesson)
💡 The ISM Code requires accidents and near misses, events that could have caused loss, to be reported and analysed for root cause, with corrective and preventive action taken, effectiveness assessed and the lesson shared on board and within the company, so that the warning is used and a near miss does not become an accident.
✗
Question 43. What does SOLAS require regarding the authorisation of a recognised organisation by the Administration?
Your Answer: (Not answered)
Correct Answer: C (A written authorisation specifying its scope, together with the responsibilities and supervision of the organisation)
💡 SOLAS I/4 requires the authorisation to be in writing, specifying its scope, conditions and responsibilities, with supervision of the organisation. The Administration remains ultimately responsible for the Convention obligations.
✗
Question 44. To which ships does the enhanced survey requirement of SOLAS XI-1/6 apply?
Your Answer: (Not answered)
Correct Answer: C (Bulk carriers and oil tankers within the scope of the enhanced programme, surveyed in accordance with the ESP)
💡 SOLAS XI-1/6 and XI-1/2 apply the enhanced programme of inspections to bulk carriers and oil tankers, with close-up survey and thickness measurement according to age and type. It does not apply to all ships.
✗
Question 45. What does SOLAS address regarding the remote control system of the main engine?
Your Answer: (Not answered)
Correct Answer: C (The main engine must be controllable from the bridge and the machinery control room, with reliable transfer between positions with indication and alarms)
💡 SOLAS requires the main engine to be controllable from both the bridge and the machinery control room, with reliable transfer between control positions and appropriate indication and alarms, preventing loss of control or misoperation during transfer.
✗
Question 46. Means of escape shall:
Your Answer: (Not answered)
Correct Answer: D (be continuous to the embarkation deck or muster station)
💡 SOLAS II-2/13 requires continuous means of escape to the embarkation deck or muster station.
✗
Question 47. The watertight door indicator showed a door open while it was in fact closed. What is the finding?
Your Answer: (Not answered)
Correct Answer: B (A deficiency; the indicator must accurately reflect the actual status, as a false indication misleads the assessment of watertight integrity)
💡 The watertight door indicator on the bridge must accurately reflect the actual open or closed status. A false indication would lead the watchkeeper to a wrong appreciation of watertight integrity and to incorrect measures after damage, so it is a deficiency affecting safety.
✗
Question 48. On what basis should a maintenance programme be prepared?
Your Answer: (Not answered)
Correct Answer: C (The manufacturer's instructions, classification society requirements and the ship's actual service experience, revised as necessary)
💡 The ISM Code requires the maintenance programme to be based on the manufacturer's instructions and the requirements of the classification society and regulations, together with the actual service history of the equipment, failure history and survey findings, and to be revised after modification or failure, so that it remains effective.
✗
Question 49. What do SOLAS and good practice address for periods when the machinery space is unattended?
Your Answer: (Not answered)
Correct Answer: B (Alarms must reliably reach the duty engineer and the bridge, with periodic rounds maintained)
💡 During unattended periods the alarm system must work reliably and transmit alarms to the engineers' accommodation or the bridge, with periodic rounds maintained so that machinery abnormalities are detected promptly. A failed alarm system is a serious deficiency.
✗
Question 50. What should be met as to the stowage position of two-way radiotelephones and SARTs?
Your Answer: (Not answered)
Correct Answer: D (They should be positioned for easy carriage to the survival craft in an abandonment, such as on the bridge and near the survival craft stations)
💡 Under SOLAS IV/7 and related requirements two-way radiotelephones and SARTs should be positioned where they can be readily obtained and taken into the survival craft during abandonment, such as on the bridge and near the survival craft stations. If stowed together there should be clear marking and ready access, so that they are not left behind.
✗
Question 51. Under specific conditions, how long may an Administration generally extend a short-term certificate?
Your Answer: (Not answered)
Correct Answer: D (Three months)
💡 Under SOLAS I/14 an Administration may, in specific circumstances, extend a certificate, generally not exceeding three months, the relevant survey being completed within the period and a new certificate issued. Extension is not exemption from survey but a short transitional arrangement.
✗
Question 52. How shall the number and capacity of lifeboats on a passenger ship be determined?
Your Answer: (Not answered)
Correct Answer: B (To accommodate the total number of persons on board)
💡 The total capacity shall accommodate all persons on board.
✗
Question 53. Which document must be readily available on board after container loading?
Your Answer: (Not answered)
Correct Answer: B (Container Packing Certificate)
💡 The Container Packing Certificate, signed by the person responsible, evidences correct stowage.
✗
Question 54. What do SOLAS and the ISM Code require in the execution of the planned maintenance programme?
Your Answer: (Not answered)
Correct Answer: B (Carry out the programme and record completion, with reasons given and re-scheduling for items not completed)
💡 ISM Code 10 requires the planned maintenance programme to be carried out with completion and any problems found recorded. Items not completed should have the reason stated, the risk assessed and the work re-scheduled, keeping equipment in good order at all times.
✗
Question 55. What is required for closing appliances on overboard discharges below the load line?
Your Answer: (Not answered)
Correct Answer: B (Effective closing appliances operable from above the bulkhead deck, preventing back flooding)
💡 SOLAS and the Load Line Convention require discharges and inlets below the load line to have effective closing appliances such as non-return valves or cocks, operable from above the bulkhead deck, preventing sea water from entering. Temporary plugs of wood are not reliable.
✗
Question 56. What shall an A-class division satisfy?
Your Answer: (Not answered)
Correct Answer: A (Be constructed of steel or equivalent and prevent passage of smoke and flame for a stated time)
💡 A-class divisions are of steel or equivalent and resist smoke and flame for the stated period.
✗
Question 57. What oxygen level is normally required before entering an enclosed space?
Your Answer: (Not answered)
Correct Answer: B (Between 19.5 and 23 per cent by volume)
💡 The oxygen content in an enclosed space should be between 19.5 and 23 per cent before entry. Below 19.5 per cent there is a risk of asphyxiation; above 23 per cent the risk of combustion and explosion increases. Both departures are unsafe.
✗
Question 58. What ventilation is required in spaces carrying dangerous goods?
Your Answer: (Not answered)
Correct Answer: A (Effective ventilation which can be shut off when necessary, removing harmful gas while allowing the air supply to be cut in a fire)
💡 SOLAS requires spaces carrying dangerous goods to have effective ventilation to remove harmful or flammable gas, with openings capable of being closed to cut off the air supply in a fire. The capacity and method of control must suit the cargo carried.
✗
Question 59. What is the fresh water requirement in a lifeboat under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (Not less than 3 litres for each person of the rated capacity, with the prescribed drinking vessel for each person)
💡 SOLAS requires not less than 3 litres of fresh water for each person of the rated capacity, with the prescribed drinking vessel for each person. Insufficient water seriously reduces survival time after abandonment.
✗
Question 60. What is the difference between the bulkhead deck and the freeboard deck under SOLAS II-1?
Your Answer: (Not answered)
Correct Answer: C (The bulkhead deck limits the extent of the main watertight bulkheads, while the freeboard deck is the datum for freeboard and load line)
💡 The bulkhead deck is the uppermost deck to which the main watertight bulkheads extend, whereas the freeboard deck is the datum for measuring freeboard and assigning load lines. Their roles in subdivision and load line calculations differ.
✗
Question 61. The purpose of a thermal protective aid is to:
Your Answer: (Not answered)
Correct Answer: A (reduce body heat loss of a person in water or after rescue)
💡 SOLAS III/32 requires thermal protective aids to reduce body heat loss.
✗
Question 62. What checking of hours of work and rest is required?
Your Answer: (Not answered)
Correct Answer: A (Daily records of hours of work and rest must be kept, meeting the minimum rest requirements and available for inspection)
💡 STCW and the MLC require daily records of hours of work and rest to be kept and retained for inspection for the prescribed period, truthfully reflecting what happened and meeting the minimum rest requirements, such as not less than 10 hours in any 24-hour period and 77 hours in any seven-day period. Falsified records are a serious breach.
✗
Question 63. VHF DSC distress and safety calls shall be transmitted on channel:
Your Answer: (Not answered)
Correct Answer: C (70)
💡 SOLAS IV/7: VHF DSC distress and safety calls are transmitted on channel 70 (156.525 MHz).
✗
Question 64. What are the key points in operating the deck foam system of a tanker?
Your Answer: (Not answered)
Correct Answer: A (It must cover the whole cargo tank deck, with the foam applied to blanket the burning surface and smother the fire)
💡 The deck foam system must be capable of covering the whole cargo tank deck area, with the foam applied so as to blanket the burning surface and exclude air, avoiding disturbance of the foam layer. Directing it only at the centre of the flames or applying incomplete coverage allows the fire to reignite.
✗
Question 65. What should be met for electrical equipment and operations in the cargo area of a tanker?
Your Answer: (Not answered)
Correct Answer: C (Explosion-protected equipment should be used and requirements such as gas testing, earthing and static protection observed to control ignition sources)
💡 In the cargo area of a tanker electrical equipment should be of the specified explosion-protected type and operations should observe requirements such as gas testing, effective earthing and protection against static electricity, including controlling flow rates and using anti-static equipment, controlling ignition sources and static discharge to prevent flammable gas from being ignited. Gas testing and a permit before operations are basic requirements.
✗
Question 66. Should satellite positioning fail, the vessel relies on which alternative means?
Your Answer: (Not answered)
Correct Answer: A (Compass bearings together with chart observation)
💡 Traditional observation with compasses and charts remains the fall-back means.
✗
Question 67. In what circumstances must an immersion suit be provided for every person on board?
Your Answer: (Not answered)
Correct Answer: D (When the ship operates in cold waters and the thermal protection provided by the survival craft is otherwise insufficient)
💡 SOLAS III/32 requires an immersion suit for every person on board when the ship operates in cold waters and the survival craft do not provide sufficient thermal protection. It is not a universal requirement in all trades.
✗
Question 68. Fire drills shall be conducted at least:
Your Answer: (Not answered)
Correct Answer: D (once a month)
💡 SOLAS III/19: fire drills shall be conducted at least once a month.
✗
Question 69. What are the limitations on the use of the automatic pilot?
Your Answer: (Not answered)
Correct Answer: B (Hand steering must be resumed in restricted visibility, dense traffic, narrow channels or when frequent manoeuvring is required)
💡 STCW and SOLAS require hand steering to be resumed in restricted visibility, dense traffic, narrow channels or when frequent manoeuvring is needed on ships using an automatic pilot. The autopilot does not reduce the number of look-outs required and the officer must be ready to steer by hand at any time.
✗
Question 70. Which high risk areas do SOLAS and the ESP require to be examined on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Hatch covers, the internal structure of top side and hopper side tanks and the corrosion and cracking of bulkheads and side structure)
💡 The ESP and SOLAS require close-up examination and thickness measurement of hatch covers, the internal structure of top side and hopper side tanks and the stiffening of bulkheads and sides, since these areas corrode readily and directly affect the longitudinal strength of the hull.
✗
Question 71. What checking of the lifeboat engine fuel system is required?
Your Answer: (Not answered)
Correct Answer: C (Check the fuel quantity and condition and the piping for leakage, renewing the fuel periodically)
💡 A lifeboat engine should have its fuel tank checked for adequate quantity, the fuel checked for deterioration, since long storage can form gum that blocks the fuel system, and the piping checked for leakage, with the fuel renewed periodically and the filters inspected, ensuring the engine starts readily when needed.
✗
Question 72. For a ship with no emergency generator, for how long shall the GMDSS reserve source of energy supply?
Your Answer: (Not answered)
Correct Answer: C (6 hours)
💡 SOLAS IV/13: the reserve source shall be capable of supplying for 6 hours on ships without an emergency generator.
✗
Question 73. What is required for stowage and securing of containers?
Your Answer: (Not answered)
Correct Answer: B (Load according to the approved securing plan and stowage plan, securing tier by tier with attention to weight distribution and the order of lashing)
💡 SOLAS and the CSS Code require containers to be loaded in accordance with the approved securing plan and stowage plan, lashed tier by tier with attention to weight distribution, heavier boxes below and avoiding uneven loading, and to the order of lashing, with weights and conditions verified, preventing stack collapse or loss overboard.
✗
Question 74. Lifeboat and liferaft launching appliances shall be capable of operating when the ship is listed by:
Your Answer: (Not answered)
Correct Answer: C (not more than 20°)
💡 SOLAS III/16 requires launching appliances to operate with the ship listed up to 20°.
✗
Question 75. What are the approval and use requirements for the Cargo Securing Manual?
Your Answer: (Not answered)
Correct Answer: C (It should be approved by the Administration and carried on board, the crew securing cargo and inspecting the securing equipment as it requires)
💡 Under SOLAS V/5 and related requirements the relevant ships should carry a Cargo Securing Manual approved by the Administration, containing the list, strength, arrangement and use of the securing devices, the crew securing cargo as it requires and inspecting and maintaining the equipment at the required intervals, recording defects and repairs.
✗
Question 76. What has to appear on the fire control plan?
Your Answer: (Not answered)
Correct Answer: C (the layout of each deck, the fire divisions and where the detecting and extinguishing gear stands, the whole agreeing with what is there)
💡 The plan is written for the people coming to fight the fire, so it must answer where to get in, what will stop the fire spreading, with what it is to be attacked and how to get out: the decks as arranged and numbered, the boundaries of class A and class B divisions and the fire zones they make, the doors and the dampers, the detection and the alarm, the systems and the appliances with where each stands, the ventilators and the means of closing them, and the ways of escape. It is made of durable material, agrees with the ship as she now is, and is altered when she is altered; a copy stands outside the bridge for the shore brigade and a copy is kept with the company. Hence marking only the extinguishers, the company settling the style, or a general arrangement drawing in place of it all fail - that drawing carries no line of fire division, no detection or extinguishing gear, and is not revised with the work. Each note on the plan is compared with the thing itself, and the commonest finding is the change that was made without the plan being changed.
✗
Question 77. For how long shall the self-contained breathing apparatus of a fireman's outfit operate as a minimum?
Your Answer: (Not answered)
Correct Answer: A (30 minutes)
💡 SOLAS requires a minimum duration of 30 minutes for the self-contained breathing apparatus.
✗
Question 78. What is required in forming main vertical zones?
Your Answer: (Not answered)
Correct Answer: C (Dividing the ship into sections by class A divisions so that fire in one section is restricted from spreading to adjacent sections)
💡 SOLAS requires main vertical zones formed by class A divisions, dividing the ship into sections so that a fire is confined to the zone in which it starts. This is the core of structural fire protection.
✗
Question 79. What is required in controlling trim during loading?
Your Answer: (Not answered)
Correct Answer: A (Maintain an appropriate stern trim or even keel, avoiding excessive trim affecting manoeuvrability, speed and structural stress)
💡 A moderate stern trim favours propeller efficiency and rudder response, but excessive trim by the stern or by the head reduces forward freeboard or lifts the propeller out, affecting manoeuvrability and speed and increasing structural stress. Trim should be controlled according to the stability and strength information.
✗
Question 80. A ship was found with an emergency fire pump that could not deliver water. The PSCO asked for test records. How often must the emergency fire pump be tested under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (Weekly, with the test recorded in the deck or engine log)
💡 SOLAS requires the emergency fire pump to be tested weekly to confirm it starts and delivers water, with the test recorded. Testing only at the annual survey does not ensure availability in an emergency.
✗
Question 81. A pilot is boarding in a swell. What arrangement must the ship provide?
Your Answer: (Not answered)
Correct Answer: C (A pilot ladder complying with the standard, combined with an accommodation ladder where required)
💡 SOLAS V/23 requires the ship to provide safe means of embarkation and disembarkation for pilots, normally a compliant pilot ladder, combined with an accommodation ladder where the freeboard is large.
✗
Question 82. Which fixed fire-extinguishing system shall be provided for the cargo tank deck area of a tanker?
Your Answer: (Not answered)
Correct Answer: A (Deck foam system)
💡 SOLAS II-2/10.5: tankers shall be fitted with a fixed deck foam system for the cargo tank deck area.
✗
Question 83. How do hinged and sliding watertight doors differ in use while the ship is at sea?
Your Answer: (Not answered)
Correct Answer: C (the hinged door shut before the ship leaves port and kept shut at sea, while a sliding door permitted to be used may be closed at any moment from the bridge and from either side)
💡 The line is drawn not by which way the door swings or how fast it shuts, but by whether it may be standing open at sea. A hinged door, open, leaves the bulkhead doing nothing, so it is to be shut before the ship parts from the port and kept shut on the voyage. A power slide sits where people must pass, so it is allowed to work at sea where permission covers it, on the terms that it can be closed at any moment from the bridge and from either side of it, that the closing has a sound and a indication, that lamps show where the door stands, that it is tested at intervals and written up, and that a document on board says which doors may be used at sea and when they must be closed, the master seeing it carried out before sailing. Whether the indication, the alarm and the local control work is a common thing to test in an inspection and in a drill; to treat it as long as somebody keeps an eye on it is the opposite of the requirement.
✗
Question 84. On receiving a distress signal at sea, what shall the master do if the ship is able to assist?
Your Answer: (Not answered)
Correct Answer: A (Proceed with all speed to assist)
💡 SOLAS V/33: the master shall proceed with all speed to assist persons in distress when able to do so.
✗
Question 85. What is the maximum renewal survey interval for the Cargo Ship Safety Radio Certificate?
Your Answer: (Not answered)
Correct Answer: B (5 years)
💡 Not exceeding 5 years.
✗
Question 86. A cargo ship completed its renewal survey in June 2020. Under SOLAS I/10, when must the subsequent annual surveys be held?
Your Answer: (Not answered)
Correct Answer: D (Every 12 months, within three months before or after the anniversary date)
💡 SOLAS I/10 requires annual surveys every 12 months, normally within a window of three months before or after the anniversary date.
✗
Question 87. What does SOLAS require regarding a look-out when the ship is under way?
Your Answer: (Not answered)
Correct Answer: A (A look-out must be posted when conditions require it, to assist the officer in maintaining a proper look-out)
💡 SOLAS and COLREG require a look-out to be posted when conditions demand it, such as in restricted visibility, dense traffic or narrow channels. The look-out's sole duty is to keep watch and report, without other tasks such as steering.
✗
Question 88. A PSC inspection found a lifeboat equipment locker locked with the key not in the boat. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: A (Equipment of survival craft must be ready for immediate use and must not be locked away)
💡 SOLAS requires survival craft equipment to be ready for immediate use. Locking it away or storing it elsewhere means it cannot be reached promptly in an abandonment, contrary to the readiness requirement, and is a deficiency.
✗
Question 89. What does SOLAS and the Polar Code require regarding manning and training for polar waters?
Your Answer: (Not answered)
Correct Answer: A (The master and officers in charge of a navigational watch must have completed appropriate polar waters training and gained the required experience)
💡 SOLAS XIV and STCW require the master and officers in charge of a navigational watch of a ship in polar waters to have completed polar waters training appropriate to the ship's category and to have the prescribed seagoing experience, ensuring the ability to operate in polar conditions.
✗
Question 90. How many means of escape, widely separated, shall be provided on each deck in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: B (Two)
💡 SOLAS II-2/13: at least two widely separated means of escape shall be provided on each deck.
✗
Question 91. During a PSC inspection the emergency fire pump discharge pressure is found below the rated value. Which finding is most likely?
Your Answer: (Not answered)
Correct Answer: A (The firefighting equipment is not capable of working effectively, a serious deficiency that may lead to detention)
💡 The emergency fire pump is a core item of the firefighting system and its capacity and pressure must meet the required values. A measured pressure below the rated value shows that the emergency firefighting capability cannot function effectively. This is a key deficiency affecting the safety of the ship, normally recorded as a detainable deficiency to be rectified before departure.
✗
Question 92. Which statement about the role of the NAVTEX receiver in sea areas A1 and A2 is correct?
Your Answer: (Not answered)
Correct Answer: D (It automatically receives and prints maritime safety information broadcast by coast stations in the area)
💡 NAVTEX is a receive-only device that automatically prints MSI such as navigational warnings and weather forecasts broadcast by coast stations on 518 kHz. It neither transmits alerts nor carries two-way traffic.
✗
Question 93. What is examined in testing a fixed fire detection and alarm system?
Your Answer: (Not answered)
Correct Answer: B (The alarm function of detectors tested point by point or by section, and that the display corresponds to the actual location)
💡 Testing a fixed detection and alarm system involves triggering detectors point by point or by section and confirming that the alarm sounds correctly and accurately indicates the space concerned, so that the watchkeeper can locate it quickly. Powering it on or listening for the sound alone does not confirm correct sectional indication.
✗
Question 94. An inert gas system on a tanker was verified during a PSC inspection. What does SOLAS require for the oxygen content in cargo tanks?
Your Answer: (Not answered)
Correct Answer: A (It must be kept at not more than 8 per cent by volume, in accordance with the prescribed limit)
💡 SOLAS and the IBC and IGC Codes require the oxygen content of inerted cargo tanks to be kept at not more than 8 per cent by volume, so that hydrocarbon vapour cannot burn. Exceeding the limit means inerting has failed, a serious deficiency.
✗
Question 95. A PSC inspection found the annual survey endorsement on a certificate three months overdue while the ship continued trading. What is the basis for action?
Your Answer: (Not answered)
Correct Answer: B (Certificates must be endorsed after annual surveys as required; an overdue survey makes the certificate invalid)
💡 SOLAS I/10 requires certificates to be endorsed after annual surveys within the validity period. Where the endorsement is overdue the certificate is no longer valid, and continued trading is a serious deficiency on which the port State may detain the ship.
✗
Question 96. What safety information does a ship in sea area A3 receive through Inmarsat-C?
Your Answer: (Not answered)
Correct Answer: A (Navigational warnings, weather warnings and search and rescue messages broadcast by enhanced group call)
💡 In sea area A3 maritime safety information is received through the enhanced group call, SafetyNET, on Inmarsat-C, including navigational warnings, weather warnings and forecasts, search and rescue messages and other safety information broadcast by coast stations. It is an important source outside NAVTEX coverage.
✗
Question 97. When must the engines be on standby?
Your Answer: (Not answered)
Correct Answer: B (In restricted visibility, dense traffic, narrow channels, when entering or leaving port and whenever immediate manoeuvring may be needed)
💡 The engine room should be given notice to stand by in restricted visibility, dense traffic, narrow channels, entering or leaving port and whenever immediate manoeuvring may be needed, so that the engine responds promptly. Without standby, manoeuvring may be delayed when it matters.
✗
Question 98. What do GMDSS procedures require for the transmission of a DSC distress alert?
Your Answer: (Not answered)
Correct Answer: C (Select the nature of distress and the subsequent communication mode as designed, then move to the appropriate frequency at once)
💡 A DSC distress alert requires the nature of distress and the subsequent communication mode to be selected as designed, such as VHF channel 16 or MF 2182 kHz, followed immediately by a move to that frequency to establish distress traffic, with a watch maintained on the equipment.
✗
Question 99. A fire hydrant in the engine room is found without its matching hose and nozzle. What should the finding be?
Your Answer: (Not answered)
Correct Answer: A (Firefighting equipment incomplete, a deficiency affecting firefighting capability, to be made good)
💡 Every fire hydrant should be provided at all times with a hose and nozzle so that firefighting can start promptly anywhere on board. Missing matching items makes that hydrant unusable. This is a deficiency of incomplete equipment affecting firefighting capability and should be made good before departure.
✗
Question 100. What should be done with a fire hose after use?
Your Answer: (Not answered)
Correct Answer: A (Clean and dry it, then roll and stow it in the proper manner in place, keeping it ready for use)
💡 After use a fire hose should be washed free of oil and salt water, dried and then rolled and stowed in the proper manner in its position, preventing rot and ageing which affect pressure resistance. Stowing it damp or exposing it long term shortens its life.