Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. What is the validity of the ISSC?
Your Answer: (Not answered)
Correct Answer: D (5 years)
💡 Not more than 5 years, subject to an intermediate verification.
✗
Question 2. Which is NOT a function of the GMDSS?
Your Answer: (Not answered)
Correct Answer: A (Commercial advertising)
💡 The GMDSS does not provide commercial advertising.
✗
Question 3. What does SOLAS VI/1 require regarding cargo information before loading ordinary cargo?
Your Answer: (Not answered)
Correct Answer: B (The shipper must provide the necessary information about the cargo before loading, so the master can judge its suitability for safe carriage)
💡 SOLAS VI/1 requires the shipper to give the master the necessary information about the cargo before loading, enabling him to judge suitability for safe carriage and the precautions needed. Experience alone or later submission does not comply.
✗
Question 4. What does SOLAS address regarding the remote control system of the main engine?
Your Answer: (Not answered)
Correct Answer: C (The main engine must be controllable from the bridge and the machinery control room, with reliable transfer between positions with indication and alarms)
💡 SOLAS requires the main engine to be controllable from both the bridge and the machinery control room, with reliable transfer between control positions and appropriate indication and alarms, preventing loss of control or misoperation during transfer.
✗
Question 5. What does a SIRE inspection focus on regarding equipment maintenance?
Your Answer: (Not answered)
Correct Answer: D (Records of execution of the maintenance programme, the condition of critical equipment and records of faults and repairs)
💡 On equipment maintenance a SIRE inspection focuses on whether the planned maintenance programme is actually carried out at the prescribed intervals with records, the real condition of critical equipment such as the main engine, steering gear, fire pumps and emergency source, records of faults and repairs and the identification of equipment and the performance of routine checks.
✗
Question 6. What is the purpose of the bilge water high level alarm in a machinery space?
Your Answer: (Not answered)
Correct Answer: C (To give an alarm when the bilge level rises abnormally, indicating flooding or failure of the drainage system)
💡 SOLAS II-1 requires a bilge water high level alarm in machinery spaces so that the watchkeeper is warned of abnormal accumulation, indicating flooding or a failure of the drainage system.
✗
Question 7. How should true and relative motion radar displays be chosen?
Your Answer: (Not answered)
Correct Answer: A (Choose the display suited to the appreciation required and be able to interpret the target's movement correctly)
💡 True and relative motion displays each have their use: relative motion allows the risk of collision and CPA to be judged quickly, while true motion shows the actual tracks of targets and the ship's position relative to them. The officer should be able to choose and interpret correctly, avoiding a wrong appreciation.
✗
Question 8. How should suggestions from the crew be adopted and fed back?
Your Answer: (Not answered)
Correct Answer: B (Reasonable suggestions should be adopted and the outcome fed back to the person who raised them, encouraging participation)
💡 The ISM system encourages the crew to take part in safety management. Reasonable suggestions should be assessed and adopted, with the outcome communicated to the person who raised them, so that the crew sees the value of participating and a virtuous circle of finding and improving develops.
✗
Question 9. Which statement about the lashing and securing of containers is correct?
Your Answer: (Not answered)
Correct Answer: A (Securing should be carried out in accordance with the approved cargo securing manual, taking account of the effect of the trading area and ship motions on the securing loads)
💡 Under SOLAS V/5 and the Code of Safe Practice for Cargo Stowage and Securing, containers and similar cargo should be lashed and secured in accordance with the approved cargo securing manual, taking account of the trading area, ship motions and accelerations on the securing loads, preventing cargo shifting or going overboard during the voyage.
✗
Question 10. Ships shall be provided with heading indication by means of:
Your Answer: (Not answered)
Correct Answer: D (a gyro-compass or magnetic compass providing heading indication on the bridge)
💡 SOLAS V/19 requires heading indication equipment providing heading to the bridge.
✗
Question 11. What does SOLAS address regarding the relationship between the rated capacity of survival craft and the persons on board?
Your Answer: (Not answered)
Correct Answer: C (The total rated capacity must meet the needs of all persons on board, with the prescribed margin)
💡 SOLAS requires the total rated capacity of the survival craft, under the rules for each side or the whole ship, to accommodate all persons on board with the prescribed margin. Insufficient capacity would leave some persons with nowhere to go on abandonment, a serious deficiency.
✗
Question 12. What does SOLAS address regarding surface materials on bulkheads in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: A (They must restrict flame spread and meet the prescribed requirements for non-combustibility and low flame spread)
💡 SOLAS II-2 prescribes requirements for non-combustibility and low flame spread for the surfaces of bulkheads, ceilings and linings, preventing rapid spread of flame over surfaces. The materials must be approved.
✗
Question 13. Which types of emergency source of power does SOLAS permit?
Your Answer: (Not answered)
Correct Answer: A (An emergency generator or a battery, supplying the emergency services for the prescribed period)
💡 SOLAS permits the emergency source to be an emergency generator or a battery. Where a battery is used its capacity must carry the emergency services, such as emergency lighting, communications and alarms, for the prescribed period.
✗
Question 14. Where must the equipment of a lifeboat be stowed?
Your Answer: (Not answered)
Correct Answer: C (Inside the boat in designated positions, secured to prevent loss or injury if the boat capsizes)
💡 SOLAS requires the equipment of a lifeboat to be stowed inside the boat in designated positions, such as a locker or secured by lashings, preventing loss or injury if the boat capsizes or during launching. The equipment belongs with the boat and must not be kept on the parent ship.
✗
Question 15. What does SOLAS address regarding drawings and documents to be kept on board?
Your Answer: (Not answered)
Correct Answer: A (Approved drawings and information must be kept on board for inspection and use)
💡 SOLAS requires approved drawings and technical information such as stability information, fire control plans and cargo securing manuals to be kept on board for use by the crew and verification at surveys. Missing drawings prevent correct operation or survey.
✗
Question 16. The ISPS Code applies to:
Your Answer: (Not answered)
Correct Answer: A (passenger ships and cargo ships of 500 GT and above engaged on international voyages)
💡 SOLAS XI-2/3: the ISPS Code applies to passenger ships and cargo ships of 500 GT and above engaged on international voyages.
✗
Question 17. What is required regarding VHF channel 16 watchkeeping?
Your Answer: (Not answered)
Correct Answer: A (Continuous watch while under way)
💡 A continuous watch on VHF channel 16 shall be kept while under way.
✗
Question 18. What is the final means required by SOLAS if the main steering power is completely lost?
Your Answer: (Not answered)
Correct Answer: B (An approved alternative steering arrangement such as an emergency tiller or independent power-driven emergency steering)
💡 SOLAS requires an approved alternative steering arrangement, such as an emergency tiller or an independent power-driven emergency steering gear, usable in an emergency, with regular drills so the crew can operate it.
✗
Question 19. What do SOLAS and good practice address regarding operational testing of a fixed foam system?
Your Answer: (Not answered)
Correct Answer: C (Periodic inspection of piping and nozzles and, as required, a discharge test to confirm the system works)
💡 SOLAS and good practice require periodic inspection of the piping, valves and nozzles of a fixed foam system for obstruction, with a discharge test as required, confirming that the system will operate when needed.
✗
Question 20. How must the electrical system perform when the ship is listed?
Your Answer: (Not answered)
Correct Answer: A (It must operate normally under the prescribed angles of list and trim, unaffected by the arrangement or oil levels)
💡 SOLAS requires generator sets, switchboards and essential electrical equipment to operate normally under the prescribed angles of list and trim, including that lubrication and fuel supply are unaffected by the inclination and that relays and switches operate reliably, ensuring electrical supply when the ship is listed after damage.
✗
Question 21. The continuous synopsis record is examined during a PSC inspection. What does the CSR record?
Your Answer: (Not answered)
Correct Answer: A (The ship's history and significant events, such as changes of name, flag, company and recognised organisation)
💡 SOLAS XI-1/5 requires the CSR to record the history of the ship and significant events, including changes of name, flag, company and recognised organisation, so that the ship's record can be traced.
✗
Question 22. What must the cargo securing manual contain under SOLAS VI/5 and the CSS Code?
Your Answer: (Not answered)
Correct Answer: C (Securing methods for the various cargo units, specifications of securing equipment and methods of strength verification)
💡 SOLAS VI/5 and the CSS Code require the cargo securing manual to contain the securing methods for the various cargo units, the specification and number of securing devices, methods of strength verification and inspection requirements, for correct securing by the crew.
✗
Question 23. What is the basic principle for selecting portable extinguishers for a machinery space?
Your Answer: (Not answered)
Correct Answer: B (the class of fire likely in the space deciding the choice, oil and electrical fires requiring a suitable agent, the number and siting as prescribed)
💡 In a machinery space the likely fires are oil and electrical. Water will spread a burning oil fire and carries the shock risk on live equipment, so it belongs to solid combustible fires; here foam, powder or carbon dioxide suits the class, with the capacity, number and siting the rules call for along passages and in spaces, placed where a hand can reach it and not blocked by gear or cargo. Carbon dioxide released in quantity in a small closed space drives the oxygen down, which has to be thought of as the party withdraws. Counting only the extinguishers and their service dates, without regard to whether the type suits the space, is a deficiency waiting to be written up and a mistake waiting to be made at the fire itself.
✗
Question 24. An extinguisher's gauge needle is in the red zone. What should be done?
Your Answer: (Not answered)
Correct Answer: B (Establish the cause and recharge or replace it; an under-pressured extinguisher cannot discharge effectively)
💡 A needle in the red zone means internal pressure is too low, perhaps through leakage or use, so the extinguisher may discharge weakly or not at all. It must be recharged or replaced at once; recharging by the crew is not permitted.
✗
Question 25. Partially enclosed and fully enclosed lifeboats must have a capacity of at least:
Your Answer: (Not answered)
Correct Answer: D (All persons on board)
💡 SOLAS III/27: such lifeboats shall have a capacity for all persons on board and shall not be overloaded.
✗
Question 26. In which spaces must a bulk carrier be fitted with water ingress detection and alarm systems?
Your Answer: (Not answered)
Correct Answer: C (Cargo holds, ballast tanks and dry spaces)
💡 SOLAS XII/12 requires water level detectors with alarms in cargo holds, ballast tanks and dry spaces so that flooding is detected early.
✗
Question 27. A pressure test found insufficient pressure when two jets were played simultaneously. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: A (Fire pumps must maintain the prescribed pressure and jets when the required number of hydrants are in simultaneous use)
💡 SOLAS II-2 requires the fire pumps to maintain the prescribed pressure and reach of the jets with the required number of hydrants in simultaneous use. Insufficient pressure impairs firefighting and is a deficiency.
✗
Question 28. What size should the international shore connection fitted on ships of 500 GT and above be?
Your Answer: (Not answered)
Correct Answer: A (65 mm)
💡 The international shore connection is 65 mm in diameter.
✗
Question 29. What do SOLAS and good practice require for emergency instructions after a distress?
Your Answer: (Not answered)
Correct Answer: D (Muster, embarkation and abandonment instructions to crew and passengers, organised in accordance with the muster list)
💡 SOLAS requires the muster list, signs and emergency announcements to enable crew and passengers to proceed in an orderly way to the muster and embarkation stations on abandonment. Independent action causes confusion and casualties.
✗
Question 30. How should near-miss reporting be organised, so that people are not penalised for reporting?
Your Answer: (Not answered)
Correct Answer: B (Create a climate in which the reporter is not punished, encouraging voluntary reporting of near misses and hazards)
💡 Effective safety management requires a climate that encourages reporting: it should be clear that reporting a near miss or hazard does not lead to punishment of the reporter, apart from wilful breach, so that the crew is willing to report. Otherwise hazards are concealed and small problems develop into accidents.
✗
Question 31. Sea area A3 means an area, excluding sea areas A1 and A2, within the coverage of:
Your Answer: (Not answered)
Correct Answer: C (an Inmarsat geostationary satellite service)
💡 SOLAS IV/2: Sea area A3 is the area, excluding A1 and A2, within the coverage of an Inmarsat geostationary satellite service.
✗
Question 32. What protection does SOLAS require for electric and electrohydraulic steering gear?
Your Answer: (Not answered)
Correct Answer: A (Short circuit and overload protection, with an alarm for single phase failure)
💡 SOLAS II-1/30 requires electric and electrohydraulic steering gear to have short circuit and overload protection and to give an alarm in the event of a single phase failure, preventing sudden loss of steering.
✗
Question 33. What do SOLAS and the related rules emphasise for position fixing in ice or polar waters?
Your Answer: (Not answered)
Correct Answer: A (Cross-check by several means, since compass and position fixing equipment may be affected by magnetic variation and signal conditions in polar regions)
💡 Magnetic variation is large in polar regions and satellite signals may be affected by ionospheric conditions. SOLAS and good seamanship require the position and heading to be cross-checked by several means, avoiding the risk from a single equipment error.
✗
Question 34. What do SOLAS V and COLREG require when navigating in a narrow channel?
Your Answer: (Not answered)
Correct Answer: A (Keep as near to the outer limit on the starboard side as is safe and practicable, at a safe speed with an adequate look-out)
💡 COLREG Rule 9 requires a vessel in a narrow channel to keep as near to the outer limit on her starboard side as is safe and practicable, at a safe speed with an adequate look-out. High speed or occupying any part of the channel greatly increases the risk of collision.
✗
Question 35. What communication is required between the ship security officer and the company security officer?
Your Answer: (Not answered)
Correct Answer: A (Report promptly on the security situation, incidents and implementation of the plan)
💡 The ISPS Code requires the ship security officer to maintain communication with the company security officer, reporting promptly on the security situation of the ship, security incidents, drills and training and the implementation of and need to revise the ship security plan, so that the company can oversee and support the ship's security.
✗
Question 36. What does SOLAS address regarding SART batteries and testing?
Your Answer: (Not answered)
Correct Answer: D (Periodic testing and checking of battery expiry, ensuring the prescribed standby and operating time)
💡 SOLAS requires periodic testing of the SART and checking of its battery condition and expiry, ensuring the prescribed standby and operating periods. An unsuitable battery means the searching radar cannot detect the survival craft.
✗
Question 37. Before a towing operation, whether towing another vessel or being towed, what should be prepared in particular?
Your Answer: (Not answered)
Correct Answer: D (Check the strength and arrangement of the towline, define the towing force and means of communication, assess stability and manoeuvring safety and prepare contingency plans)
💡 Before a towing operation the strength and arrangement of the towline, including the emergency towline, should be checked, the towing force and speed determined, the manoeuvring and communication arrangements, including emergency signals, defined, the stability and manoeuvring safety of both vessels assessed and contingency plans for a towline failure prepared. A continuous lookout and communication should be maintained during the tow.
✗
Question 38. The engine telegraph shall display orders and replies:
Your Answer: (Not answered)
Correct Answer: C (both on the bridge and in the engine room control position)
💡 SOLAS II-1/31 requires the telegraph to display orders and replies both on the bridge and at the engine control position.
✗
Question 39. For free-fall lifeboats, drills shall include:
Your Answer: (Not answered)
Correct Answer: D (a free-fall launch at the required interval or an equivalent approved method)
💡 SOLAS III/19 requires free-fall lifeboats to be free-fall launched at the prescribed interval or by an approved equivalent method.
✗
Question 40. What do SOLAS and the related standards address regarding electromagnetic compatibility of radio equipment?
Your Answer: (Not answered)
Correct Answer: C (Equipment must not cause harmful interference and must not be rendered ineffective by interference from other equipment)
💡 SOLAS and the IEC standards require ship radio equipment to be electromagnetically compatible, neither disturbing other equipment such as navigational aids nor being rendered ineffective by interference from them.
✗
Question 41. What launching and recovery time must a rescue boat achieve under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (Launch and recover within not more than 5 minutes in moderate sea conditions)
💡 SOLAS requires a rescue boat to be launched and recovered within not more than 5 minutes in moderate sea conditions, so that a person in the water is recovered as quickly as possible. A longer time significantly reduces the chance of success.
✗
Question 42. What is required when life-saving appliances are changed on board?
Your Answer: (Not answered)
Correct Answer: B (Replace with approved equipment of equal or better performance and update the records and certificate attachments)
💡 Life-saving appliances should be replaced with approved equipment of the same or better performance, with the equipment records and certificate attachments such as the record of equipment for the cargo ship safety equipment certificate updated and the classification society informed for verification where necessary.
✗
Question 43. What is the basic requirement for navigation lights used at night or in restricted visibility?
Your Answer: (Not answered)
Correct Answer: B (They must be displayed in accordance with the requirements, with indicators or failure alarms on the bridge)
💡 SOLAS V/19 requires navigation lights to comply with COLREG and to have indicators or failure alarms on the bridge, so that the ship can be identified at night and in restricted visibility.
✗
Question 44. For how long must the GMDSS reserve source of energy supply the radio installation when the main source fails under SOLAS IV/9?
Your Answer: (Not answered)
Correct Answer: C (At least one hour, for both passenger and cargo ships)
💡 SOLAS IV/9 requires the reserve source to supply the radio installation for at least one hour. The 18-hour figure applies to emergency lighting on cargo ships under a different regulation.
✗
Question 45. What should be done if the loading instrument of a bulk carrier computes abnormally?
Your Answer: (Not answered)
Correct Answer: D (Stop relying on it and use an approved manual method or shore support, repairing and verifying it as soon as possible)
💡 If a loading instrument computes abnormally, such as results clearly differing from hand calculation or the program reporting errors, reliance on it should cease and an approved manual method or shore support used to complete the strength and stability checks, with the instrument repaired and verified as soon as possible, preventing a wrong result from causing overloading or structural damage.
✗
Question 46. What must the navigational safety measures for polar waters include?
Your Answer: (Not answered)
Correct Answer: D (A voyage plan taking account of ice conditions, visibility and the ship's capabilities, with action to be taken if they are exceeded)
💡 The Polar Code requires the voyage plan for polar waters to consider ice conditions, visibility, the ship's ice class capability and the experience of the crew, and to state the action to be taken if conditions exceed the ship's capabilities, such as altering course or stopping.
✗
Question 47. What is the principal means by which a flag State discharges its supervision?
Your Answer: (Not answered)
Correct Answer: A (Issuing valid certificates and carrying out surveys)
💡 Certification and survey are the principal means of flag State supervision.
✗
Question 48. What does SOLAS II-2 require for paint lockers and flammable liquid lockers?
Your Answer: (Not answered)
Correct Answer: C (A suitable fire-extinguishing arrangement, such as a fixed system or equivalent)
💡 SOLAS II-2/15 requires paint and flammable liquid lockers to be provided with a suitable extinguishing arrangement because of the high fire load and rapid spread in such spaces.
✗
Question 49. What should be noted about the use of distress signals during drills?
Your Answer: (Not answered)
Correct Answer: A (Signals should not be fired in a drill unless necessary; if fired, the direction and safety must be confirmed and the matter recorded)
💡 Distress signals are dangerous goods with a limited life. They are not normally fired in a drill, alternative means being used to check them. If firing is genuinely required, the direction and the safety of the surroundings must be confirmed, the bridge informed and the expenditure recorded, avoiding misunderstanding or danger.
✗
Question 50. A ship is found not to have carried out and recorded the emergency steering drill within the recent period. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Emergency steering drills must be held and recorded at the required intervals; failure is an SMS and operational deficiency)
💡 Emergency steering drills should be held at regular intervals so that the crew are familiar with the procedures for steering by the emergency steering gear when the main steering fails. Failure to hold or record them shows that emergency preparedness and training are inadequate. It is a deficiency to be corrected.
✗
Question 51. A Cargo Ship Safety Radio Certificate shall be issued for a period not exceeding:
Your Answer: (Not answered)
Correct Answer: C (5 years)
💡 SOLAS I/12 requires a Cargo Ship Safety Radio Certificate for a period not exceeding 5 years.
✗
Question 52. Bulk carriers required to be fitted with water level detectors are those of:
Your Answer: (Not answered)
Correct Answer: D (500 GT and above)
💡 SOLAS XII/12: bulk carriers of 500 GT and above shall be fitted with water level detectors in cargo holds.
✗
Question 53. Below which value shall the inert gas system maintain the oxygen content in cargo tanks?
Your Answer: (Not answered)
Correct Answer: A (8% by volume)
💡 SOLAS requires the oxygen content to be maintained at not more than 8% by volume.
✗
Question 54. When a fixed CO2 system serves a machinery space, what key parameter does SOLAS address?
Your Answer: (Not answered)
Correct Answer: C (The quantity released must achieve the prescribed extinguishing concentration and the space must be reasonably gas-tight)
💡 SOLAS requires the CO2 quantity to be calculated from the volume of the space to achieve the prescribed concentration, and the space to be reasonably gas-tight so that leakage does not defeat the system.
✗
Question 55. What is sea area A1?
Your Answer: (Not answered)
Correct Answer: D (An area within coverage of at least one VHF coast station)
💡 An area within coverage of at least one VHF coast station with DSC.
✗
Question 56. The shipper shall provide the ship with cargo information before loading, including:
Your Answer: (Not answered)
Correct Answer: A (information necessary for proper stowage and securing, such as weight and stowage factor)
💡 SOLAS VI/5: the shipper shall provide, before loading, information necessary for proper stowage and securing such as weight and stowage factor.
✗
Question 57. How must key shipboard operations such as cargo handling, enclosed space entry and hot work be managed?
Your Answer: (Not answered)
Correct Answer: C (Plans and instructions must be established for key operations, with designated persons in charge and execution under the prescribed procedures)
💡 ISM Code 7 requires plans and instructions for key shipboard operations, with responsibilities and procedures defined. Operations involving several persons require a designated person in charge and maintained communication, preventing accidents from misunderstandings.
✗
Question 58. A watertight door is found unable to be closed remotely from the bridge. The finding is?
Your Answer: (Not answered)
Correct Answer: A (Watertight doors must be remotely closable with indication of their open or closed position; failure affects subdivision integrity)
💡 Where subdivision requires it a watertight door, especially a remotely controlled one, must be capable of remote closure from the central control station on the bridge with position indication there. Loss of remote control affects the ability to close doors rapidly and maintain subdivision integrity in the event of flooding. It is a deficiency to be corrected.
✗
Question 59. For how long shall the reserve source of energy for radio installations supply?
Your Answer: (Not answered)
Correct Answer: B (6 hours)
💡 Six hours on ships without an emergency generator.
✗
Question 60. What are the main items checked when an inflatable liferaft is serviced?
Your Answer: (Not answered)
Correct Answer: B (Tightness of the raft, the inflation system, the equipment, the weak link and the hydrostatic release unit)
💡 Servicing an inflatable liferaft covers a tightness test, the inflation system including cylinder pressure and valves, the completeness and expiry of the equipment and the condition of the weak link and hydrostatic release unit. Failure of any of these would affect use after abandonment.
✗
Question 61. What must be carefully considered when loading high density cargo into a bulk carrier?
Your Answer: (Not answered)
Correct Answer: C (Hull structural strength and the loading rate)
💡 Hull structural strength and the rate of loading must be controlled.
✗
Question 62. What restrictions apply to hot work or hammering on a tanker in port?
Your Answer: (Not answered)
Correct Answer: A (Hot work and spark-producing operations are prohibited in the cargo area and spaces where vapour may accumulate, requiring a hot work permit)
💡 Hot work and spark-producing operations such as hammering, cutting or the use of non-protected tools are prohibited in the cargo area and nearby spaces on a tanker. Where hot work is genuinely necessary, a permit must be obtained under the procedure with gas testing and firefighting standby completed.
✗
Question 63. What may follow if a port State inspection finds a deficiency seriously affecting safety?
Your Answer: (Not answered)
Correct Answer: A (The ship may be detained until the deficiency is rectified and the flag State and recognised organisation notified)
💡 Under PSC procedures, where a deficiency seriously endangers the ship, persons or the environment, the port State may detain the ship until it is rectified, normally notifying the flag State and recognised organisation. A deadline or a record alone is not enough for a serious deficiency.
✗
Question 64. What is required for checking the pressure of firefighter's breathing apparatus cylinders?
Your Answer: (Not answered)
Correct Answer: A (Periodic checks of cylinder pressure and tightness, with refilling or replacement when pressure is low)
💡 Breathing apparatus cylinders should be checked periodically for pressure, normally not less than 80 to 90 per cent of the rated pressure, and for tightness, with refilling or replacement when low or expired. Running short of air inside a fire is fatal.
✗
Question 65. What length must a rescue boat have under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Not less than 3.8 m and not more than 8.5 m)
💡 SOLAS requires a rescue boat to be not less than 3.8 m and not more than 8.5 m in length, balancing carrying capability against the ability to be manoeuvred and recovered quickly. Too small gives insufficient capacity, too large hinders rapid handling.
✗
Question 66. How shall watertight doors be operable locally?
Your Answer: (Not answered)
Correct Answer: B (By two persons, one from each side)
💡 They shall be operable locally by two persons, one from each side.
✗
Question 67. What does SOLAS chapter III say about the performance standards for life-saving appliances?
Your Answer: (Not answered)
Correct Answer: C (the performance standards of the International Life-Saving Appliance Code, or other appliances accepted by the Administration as equally safe)
💡 Chapter III requires appliances to comply with the International Life-Saving Appliance Code, which standardises the testing and performance of rafts, boats, launching and embarkation appliances, fittings and pyrotechnics. Other appliances of equal safety may be accepted by the Administration, but only through type approval on the record. Class rules cover structure and machinery and do not set life-saving performance; a contractual specification below the Code prevents the issue of the equipment safety certificate and will be listed on inspection.
✗
Question 68. What is the hazardous characteristic of a Group A solid bulk cargo under the IMSBC Code?
Your Answer: (Not answered)
Correct Answer: B (It may liquefy if shipped above the TML, causing cargo shift and capsize)
💡 Group A cargoes contain fines and moisture and may liquefy, causing a shift of cargo and loss of stability. The hazard is physical, not chemical.
✗
Question 69. What does SOLAS and the Polar Code require regarding manning and training for polar waters?
Your Answer: (Not answered)
Correct Answer: A (The master and officers in charge of a navigational watch must have completed appropriate polar waters training and gained the required experience)
💡 SOLAS XIV and STCW require the master and officers in charge of a navigational watch of a ship in polar waters to have completed polar waters training appropriate to the ship's category and to have the prescribed seagoing experience, ensuring the ability to operate in polar conditions.
✗
Question 70. What reporting is required after a detention by PSC?
Your Answer: (Not answered)
Correct Answer: A (Report the detention, the deficiencies and the rectification arrangements to the flag State, the recognised organisation and the company as required)
💡 After a detention the ship should report the detention, the deficiencies and the plan to rectify to the flag State, the recognised organisation where relevant and the company, keeping the records. The flag State normally requires a detention report and evidence of rectification; this is mandatory.
✗
Question 71. What is the main value of combining radar with ARPA?
Your Answer: (Not answered)
Correct Answer: C (Automatic tracking and computation of relative motion to assess collision risk)
💡 ARPA tracks targets automatically and computes CPA/TCPA to assess collision risk.
✗
Question 72. What safety information does a ship in sea area A3 receive through Inmarsat-C?
Your Answer: (Not answered)
Correct Answer: A (Navigational warnings, weather warnings and search and rescue messages broadcast by enhanced group call)
💡 In sea area A3 maritime safety information is received through the enhanced group call, SafetyNET, on Inmarsat-C, including navigational warnings, weather warnings and forecasts, search and rescue messages and other safety information broadcast by coast stations. It is an important source outside NAVTEX coverage.
✗
Question 73. What may result from insufficient height of the hatch coaming?
Your Answer: (Not answered)
Correct Answer: B (Water shipping into the hold)
💡 The coaming height is set so that shipping or sea water cannot enter the hold.
✗
Question 74. What does SOLAS require regarding the arrangement of scuppers, inlets and discharges on a ship's sides?
Your Answer: (Not answered)
Correct Answer: C (They must not lead water into spaces where it would be dangerous, and reliable means of closure must be fitted)
💡 SOLAS II-1 regulates the arrangement and closing appliances of overboard scuppers and inlets so that water cannot enter spaces where it would create a hazard through damage or inadvertent operation.
✗
Question 75. What should be noted about launching lifeboats while the ship has headway?
Your Answer: (Not answered)
Correct Answer: A (Reduce speed or stop if possible before launching, avoiding the boat being swept away or striking the hull)
💡 A lifeboat should be launched with speed reduced or the ship stopped where possible, since headway produces a flow that can sweep the boat away or dash it against the hull. If stopping is impossible in an emergency, the boat should be launched on the lee side with due preparation.
✗
Question 76. What is the main purpose of establishing restricted areas under the ship security plan?
Your Answer: (Not answered)
Correct Answer: C (To prevent unauthorised access and the introduction of weapons or dangerous articles)
💡 ISPS Code Part A/10 requires restricted areas to be identified and controlled in order to prevent unauthorised access and the introduction of weapons or dangerous articles on board. Convenience of operations is not the purpose.
✗
Question 77. What should be done if insulation on a fire division becomes damp, falls off or is removed?
Your Answer: (Not answered)
Correct Answer: D (Repair or replace promptly to restore the fire rating, using approved material)
💡 Damp, missing or removed insulation on a class A division reduces its fire performance and should be replaced promptly with approved material to restore the original rating. Substituting ordinary material or timber destroys the protective function of the division.
✗
Question 78. What is required for maintenance and inspection of radio equipment?
Your Answer: (Not answered)
Correct Answer: A (Periodic inspection and maintenance to keep it ready for use)
💡 Periodic inspection and maintenance to keep it available at all times.
✗
Question 79. What first aid is required for an injury at sea?
Your Answer: (Not answered)
Correct Answer: C (Give first aid at once, inform the bridge and request medical advice as necessary, recording the injury and treatment)
💡 An injury requires immediate first aid, the bridge and master being informed and medical advice requested where necessary, including a MEDEVAC, with the injury, time and treatment recorded. Delay worsens the outcome, particularly on an ocean passage.
✗
Question 80. Indication of propeller pitch and speed shall show:
Your Answer: (Not answered)
Correct Answer: B (pitch (where applicable), propeller speed and direction of rotation)
💡 SOLAS V/19: the bridge shall be provided with indicators for pitch (where applicable), propeller speed and direction of rotation.
✗
Question 81. What work do the liferaft painter and the weak link in its falls each do?
Your Answer: (Not answered)
Correct Answer: A (the painter tensioning as the raft leaves the cradle to start inflation, the weak link parting when a sinking ship's pull exceeds its strength so the raft frees itself)
💡 The painter is made fast to the ship and to the raft: as the raft leaves the cradle the painter strains and pulls the inflation valve, so the raft is inflated at the water; if the ship goes down, the load on the painter exceeds the weak link and the link parts, freeing the raft instead of dragging it under. The hydrostatic release unit is the other route, releasing the lashings at about 15 metres of depth. The three work together, and the loss of any one may leave the raft down with the ship or unpumped on the surface.
✗
Question 82. What is the sequence of immediate actions after a person falls overboard?
Your Answer: (Not answered)
Correct Answer: A (Throw a lifebuoy on the side of the casualty at once, sound the man overboard alarm, inform the bridge and carry out the turning manoeuvre)
💡 The standard response to a person overboard is to throw a lifebuoy with light and smoke on the side of the casualty at once, press the man overboard alarm, inform the bridge and carry out the practised turning manoeuvre to return to the position as quickly as possible, with a person detailed to keep the casualty in sight.
✗
Question 83. Which means of look-out meets SOLAS requirements?
Your Answer: (Not answered)
Correct Answer: A (Sight, hearing and all available means appropriate to the circumstances)
💡 Sight, hearing and all available means appropriate to the circumstances.
✗
Question 84. One space uses smoke detectors and another heat detectors. What is the main basis for choosing detector type?
Your Answer: (Not answered)
Correct Answer: A (The type and characteristics of fire likely in the space, such as smoke production or rapid temperature rise)
💡 SOLAS requires the detector type to suit the fire expected in the space: smoke detectors where smoke will be produced, heat detectors where rapid temperature rise without much smoke may occur. The wrong choice delays the alarm.
✗
Question 85. What does SOLAS address regarding the stowage of lifebuoys?
Your Answer: (Not answered)
Correct Answer: C (Stowed where they can be quickly released, not locked or lashed)
💡 SOLAS requires lifebuoys to be stowed so they can be released at once. Locking them or lashing them down means a lifebuoy cannot be thrown immediately when a person falls overboard, a common deficiency.
✗
Question 86. What is the purpose of the rescue quoit in a lifeboat's equipment?
Your Answer: (Not answered)
Correct Answer: A (Thrown to a person in the water to be grasped, the line being used to pull the person alongside)
💡 A rescue quoit with its buoyant line is thrown to a person in the water to be grasped, and the rescuers pull the person alongside using the line before lifting him out. It is basic equipment for recovering a person from the water and a key item in a rescue boat's equipment.
✗
Question 87. What condition regarding the suction of the emergency fire pump does SOLAS address?
Your Answer: (Not answered)
Correct Answer: D (It must be capable of drawing water under all operating draughts and trims of the ship)
💡 SOLAS requires the emergency fire pump suction to be arranged so that water can be drawn under all operating draughts and trims. Otherwise it may fail in a particular condition, a common ground for detention.
✗
Question 88. What requirement shall navigation lights meet?
Your Answer: (Not answered)
Correct Answer: C (The lights requirements of COLREG)
💡 They shall comply with the lights requirements of COLREG.
✗
Question 89. What is required for checking the tightness of hatch covers on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Periodic inspection of seals, cleats and drain channels with a hose test to verify weathertightness)
💡 SOLAS requires the hatch covers of a bulk carrier to remain weathertight, with periodic checks of seal ageing, the effectiveness of cleats and the clearance of drain channels, and a hose test where necessary to verify tightness, preventing sea water from entering the holds and damaging structure and cargo.
✗
Question 90. What do SOLAS and GMDSS procedures require when a ship receives a distress alert from another ship?
Your Answer: (Not answered)
Correct Answer: B (Acknowledge it under the procedures and take the appropriate action, relaying if necessary, without transmitting anything that would interfere with distress traffic)
💡 GMDSS procedures require a distress alert to be acknowledged under the procedures and appropriate action taken, such as relaying it, informing a coast station or proceeding to assist, while nothing unrelated is transmitted on the distress frequency to interfere with the traffic.
✗
Question 91. A newly joined crew member is found not to have completed familiarisation training and records before the ship sailed. The finding is?
Your Answer: (Not answered)
Correct Answer: A (New crew should complete familiarisation before taking up duties; absence is a training deficiency)
💡 Before taking up duties on board a crew member should receive familiarisation training on the ship's life-saving and firefighting equipment, emergency duties and relevant procedures, with records kept. Absence leaves the crew member unable to act correctly in an emergency. It is a training and management deficiency to be corrected.
✗
Question 92. What is required for the frequency of position checks?
Your Answer: (Not answered)
Correct Answer: A (Determined by the trading area and navigational conditions, with more frequent checks in confined waters)
💡 The frequency of position checks should be determined by the risks of the area and the navigational conditions: longer intervals may be acceptable in open waters, while in confined waters, coastal passages and when entering port checks should be more frequent, such as at short intervals or at every alteration, ensuring deviations and dangers are detected in time.
✗
Question 93. What is the basic SOLAS II-1/42 requirement for the location of the emergency generator and its prime mover?
Your Answer: (Not answered)
Correct Answer: C (Outside category A machinery spaces, with an independent fuel supply)
💡 SOLAS II-1/42 requires the emergency source of power to be located outside category A machinery spaces so it remains available if that space is on fire, with a separate fuel supply.
✗
Question 94. What does SOLAS XI-2/8 provide regarding the master's authority and responsibility for security?
Your Answer: (Not answered)
Correct Answer: C (The master has ultimate responsibility for the safety and security of the ship and authority to make necessary decisions)
💡 SOLAS XI-2/8 emphasises that the master has ultimate responsibility for the safety and security of the ship and the authority to take necessary decisions, seeking company or port facility assistance as needed, free of constraint by owner or charterer.
✗
Question 95. What preventive measures do SOLAS and the IMO circulars emphasise for accidents during survival craft drills?
Your Answer: (Not answered)
Correct Answer: B (Use tested release gear, ensure familiarity with the procedure and avoid hazardous launch conditions)
💡 Accidents during boat drills commonly arise from defective release gear or mishandling. The IMO circulars require tested gear, strict adherence to the procedure and prudent choice of conditions, not the cancellation of drills.
✗
Question 96. What must the emergency fire pump satisfy in respect of capacity and pressure?
Your Answer: (Not answered)
Correct Answer: D (Maintain the prescribed pressure at the fire main with the required number of hydrants in simultaneous use)
💡 SOLAS requires the emergency fire pump to maintain the prescribed pressure and reach at the fire main with the required number of hydrants in simultaneous use, so that effective firefighting is possible in an emergency.
✗
Question 97. What must be checked on board when loading containers under SOLAS and the CSS Code?
Your Answer: (Not answered)
Correct Answer: D (The weight, position and securing of containers, preventing structural damage or securing failure from overweight boxes)
💡 SOLAS VI/2 requires the declared weight of containers to be verified against actual weight and securing carried out in accordance with the securing manual. Overweight boxes or improper securing cause structural damage and loss of cargo overboard.
✗
Question 98. Under SOLAS I/2, from what point does a ship under construction become subject to the Convention?
Your Answer: (Not answered)
Correct Answer: C (From the date the keel is laid or the ship is at a similar stage of construction)
💡 SOLAS uses keel laying, or a comparable identifiable stage of construction, as the date determining which standards apply to a new ship. Launching and delivery are not the reference points.
✗
Question 99. What items does the stability assessment after loading include?
Your Answer: (Not answered)
Correct Answer: D (Initial metacentric height, the righting lever curve, the maximum righting lever and the weather criterion)
💡 Intact stability assessment normally includes the initial metacentric height, the shape and range of the righting lever curve, the maximum righting lever and its angle and the weather criterion, the ratio of heeling to righting moment. Calculating the initial metacentric height alone does not ensure intact stability.
✗
Question 100. What emergency supplies are required in polar waters?
Your Answer: (Not answered)
Correct Answer: D (Sufficient warm clothing, emergency food and water, heating means and emergency lighting)
💡 The Polar Code requires emergency supplies suited to the polar environment: ample warm clothing and thermal protection, emergency food and water, means of heating such as a spare heater, emergency lighting and communication equipment, in view of the long search and rescue response times.