Question 1. What shall the training manual for life-saving appliances contain?
Your Answer: (Not answered)
Correct Answer: C (Instructions on the use of each appliance and survival information)
💡 Instructions on using each appliance and survival information.
✗
Question 2. What authority does the master have in security matters?
Your Answer: (Not answered)
Correct Answer: D (To make security decisions that affect the safety of the ship)
💡 The master may make security decisions affecting the safety of the ship.
✗
Question 3. In restricted visibility, the look-out shall use:
Your Answer: (Not answered)
Correct Answer: C (Sight, hearing and all available means appropriate to the circumstances)
💡 SOLAS V/30: in restricted visibility all available means appropriate to the circumstances shall be used.
✗
Question 4. After a dead-ship condition, propulsion shall be restorable within:
Your Answer: (Not answered)
Correct Answer: D (30 minutes)
💡 Propulsion shall be restored within 30 minutes of a dead-ship condition.
✗
Question 5. What is required for the repeaters of a gyrocompass and their alignment?
Your Answer: (Not answered)
Correct Answer: D (Repeaters should agree with the master compass and be aligned as required; if the error exceeds the limit the cause should be found and corrected)
💡 Under SOLAS V/19 and related requirements the repeaters of a gyrocompass should agree with the master compass and be checked against it at the required intervals, any error exceeding the limit being investigated and corrected, such as by adjusting the repeater or servicing the master compass. The reliability of the heading reference directly affects navigational safety.
✗
Question 6. In SOLAS I/2 the expression "upright position" is used to define which condition of the ship?
Your Answer: (Not answered)
Correct Answer: B (The reference condition with no heel, used for measuring freeboard and similar particulars)
💡 SOLAS and the Load Line Convention take the upright (no heel) condition as the datum for measuring moulded depth, freeboard and similar particulars, irrespective of the loading condition.
✗
Question 7. What should be done if dangerous goods packages are found damaged on board?
Your Answer: (Not answered)
Correct Answer: B (Take the measures in the EmS Guide, segregate the damaged packages, protect personnel and assess whether carriage may continue)
💡 On discovering damaged packages of dangerous goods, the measures in the EmS Guide should be taken: segregating the damaged packages, protecting personnel and ventilating, collecting the spillage and notifying the port and the company where necessary, assessing whether carriage may continue or the goods must be discharged. Discarding them at random or ignoring the matter is not acceptable.
✗
Question 8. For how long shall the self-contained breathing apparatus of a fireman's outfit operate as a minimum?
Your Answer: (Not answered)
Correct Answer: A (30 minutes)
💡 SOLAS requires a minimum duration of 30 minutes for the self-contained breathing apparatus.
✗
Question 9. What does SOLAS address regarding the watertight integrity of spaces above the bulkhead deck?
Your Answer: (Not answered)
Correct Answer: C (Openings must be fitted with effective closing appliances to prevent sea water entering the hull through them)
💡 SOLAS requires openings such as doors, side scuttles and ventilators above the bulkhead deck to have effective closing appliances, preventing sea water from entering the hull and causing loss of stability.
✗
Question 10. From what tonnage shall the main steering gear have two independent power units?
Your Answer: (Not answered)
Correct Answer: D (10000 GT)
💡 From 10000 GT and above.
✗
Question 11. Where shall emergency escape breathing devices be provided?
Your Answer: (Not answered)
Correct Answer: C (On means of escape that may be affected by smoke)
💡 EEBDs are provided on means of escape that may be affected by smoke.
✗
Question 12. In which spaces must a bulk carrier be fitted with water ingress detection and alarm systems?
Your Answer: (Not answered)
Correct Answer: C (Cargo holds, ballast tanks and dry spaces)
💡 SOLAS XII/12 requires water level detectors with alarms in cargo holds, ballast tanks and dry spaces so that flooding is detected early.
✗
Question 13. A PSC inspection found a lifeboat equipment locker locked with the key not in the boat. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: A (Equipment of survival craft must be ready for immediate use and must not be locked away)
💡 SOLAS requires survival craft equipment to be ready for immediate use. Locking it away or storing it elsewhere means it cannot be reached promptly in an abandonment, contrary to the readiness requirement, and is a deficiency.
✗
Question 14. On what basis is the extent of close-up survey determined?
Your Answer: (Not answered)
Correct Answer: A (Ship type, age, cargo characteristics and known high risk areas taken together)
💡 The ESP requires the extent of close-up survey to be determined by the ship type and age, the characteristics of the cargoes carried, such as the corrosive or abrasive effect of coal and ore, and the known high risk areas such as hatch coamings and hopper tanks, supported by a survey programme.
✗
Question 15. What is the usual weekly running requirement for a lifeboat engine?
Your Answer: (Not answered)
Correct Answer: D (Run at least once each week for not less than the prescribed period, normally three minutes or more)
💡 SOLAS requires the lifeboat engine to be run at least once each week for not less than the prescribed time, bringing it to normal operating condition. Annual testing alone does not ensure the engine will start in an abandonment.
✗
Question 16. Fire drills shall be conducted at least:
Your Answer: (Not answered)
Correct Answer: D (once a month)
💡 SOLAS III/19: fire drills shall be conducted at least once a month.
✗
Question 17. An inflatable liferaft shall be serviced at intervals not exceeding:
Your Answer: (Not answered)
Correct Answer: D (12 months)
💡 SOLAS III/36 (LSA Code) requires inflatable liferafts to be serviced at intervals not exceeding 12 months.
✗
Question 18. With regard to charts, which requirement is correct?
Your Answer: (Not answered)
Correct Answer: A (up-to-date charts covering the intended voyage shall be carried)
💡 SOLAS V/27 requires up-to-date charts covering the intended voyage.
✗
Question 19. What should be noted about fog signals in restricted visibility?
Your Answer: (Not answered)
Correct Answer: A (Sound fog signals as COLREG prescribes and listen attentively to other vessels' signals to judge bearing and movement)
💡 In restricted visibility fog signals should be sounded as COLREG prescribes, for example one prolonged blast at intervals of not more than two minutes for a power-driven vessel under way, while listening carefully to other vessels' signals to judge their approximate bearing and movement, combined with radar observation. Sounding must not be delayed.
✗
Question 20. What checking is required of the electrical insulation of firefighter's boots?
Your Answer: (Not answered)
Correct Answer: C (Check the soles for damage, perforation and loss of insulating properties, replacing them at once if defective)
💡 Firefighter's boots should be checked for damage, perforation, ageing and loss of insulating properties in the soles. Damaged boots expose the firefighter to injury in a live electrical or high temperature environment and must be replaced at once, forming part of the routine inspection of the outfit.
✗
Question 21. What does SOLAS address regarding the effect on stability of loading high density cargo?
Your Answer: (Not answered)
Correct Answer: C (A low centre of gravity increases the initial metacentric height but may cause violent rolling and increased structural stress)
💡 High density cargo stowed low produces an excessive initial metacentric height and a stiff ship with a short rolling period and violent rolling, which may shift cargo and increase structural stresses. Stability should therefore be kept within a reasonable range.
✗
Question 22. What do SOLAS and good practice address regarding the inspection of the propulsion shafting?
Your Answer: (Not answered)
Correct Answer: A (Periodic inspection of the tail shaft, intermediate shaft and bearings for wear, sealing and alignment)
💡 SOLAS and the classification societies require periodic inspection of the propulsion shafting for stern tube sealing, bearing wear and alignment, detecting abnormalities that could cause oil leakage, vibration or shaft failure with loss of propulsion.
✗
Question 23. What does security level 2 signify?
Your Answer: (Not answered)
Correct Answer: B (A heightened risk of a security incident requiring additional protective measures)
💡 Under the ISPS Code level 1 is the minimum in normal circumstances, level 2 additional measures when risk is heightened, and level 3 specific measures when an incident is probable or imminent. The measures escalate by level.
✗
Question 24. What is the primary function of a satellite EPIRB?
Your Answer: (Not answered)
Correct Answer: D (To alert the shore and provide the distress position)
💡 On activation the EPIRB alerts a rescue centre and provides the distress position.
✗
Question 25. What layers of protection do SOLAS and the IMO resolutions require for enclosed space entry?
Your Answer: (Not answered)
Correct Answer: B (Ventilation, testing, a permit, a standby person and rescue preparation forming a complete entry procedure)
💡 SOLAS and the IMO resolutions require a complete procedure for enclosed space entry: ventilation, testing, a permit, a standby person and rescue arrangements. The layers work together; no single measure ensures safety.
✗
Question 26. What is the general requirement for the location of embarkation stations?
Your Answer: (Not answered)
Correct Answer: A (Where persons can board safely, as far as practicable from the propulsion plant and dangerous goods)
💡 SOLAS requires embarkation stations to be located where persons can board safely, taking account of the need to be clear of propellers, thrusters, exhausts and dangerous goods, so that persons are not injured while boarding and the operation is possible even if the ship still has headway.
✗
Question 27. Which document must be kept on the bridge for use by the watchkeepers?
Your Answer: (Not answered)
Correct Answer: C (A table of ship particulars)
💡 A table of ship particulars is kept on the bridge for reference by the watch.
✗
Question 28. How many masthead lights shall a power-driven vessel of less than 50 m in length exhibit when under way?
Your Answer: (Not answered)
Correct Answer: B (One)
💡 COLREG Rule 23: a power-driven vessel under 50 m may exhibit one masthead light (two for 50 m and over).
✗
Question 29. Under Chapter XI-1, the flag State shall discharge its supervision:
Your Answer: (Not answered)
Correct Answer: C (Through surveys and certification)
💡 Through surveys, certification and, where necessary, additional inspections.
✗
Question 30. The VDR is found not to have recorded the bridge audio and radar images of the recent voyage. The finding is?
Your Answer: (Not answered)
Correct Answer: C (The VDR must continuously record the required data; failure to record affects accident investigation)
💡 The VDR is used to reconstruct the navigation and decisions at the time of an accident and should continuously record the required data, such as position, speed, radar images, bridge audio and alarms. Failure to record key data deprives an accident investigation of its basis. It is a deficiency to be corrected.
✗
Question 31. What electrical equipment is required in a pump room on a tanker?
Your Answer: (Not answered)
Correct Answer: B (Explosion-protected equipment, with the number of items and wiring minimised)
💡 A pump room is a high-risk space where hydrocarbon vapour can accumulate. SOLAS and the IBC Code require explosion-protected equipment with the number of items and wiring kept to a minimum, preventing electrical sparks from igniting vapour.
✗
Question 32. The securing of cargo units such as containers shall be carried out in accordance with:
Your Answer: (Not answered)
Correct Answer: A (the approved Cargo Securing Manual)
💡 SOLAS VI/5 requires securing of cargo units in accordance with the approved Cargo Securing Manual.
✗
Question 33. What does SOLAS address regarding openings in watertight bulkheads, such as piping and cable penetrations?
Your Answer: (Not answered)
Correct Answer: A (Penetrations must maintain watertightness, using approved sealing methods with records kept)
💡 SOLAS requires piping and cable penetrations of watertight bulkheads to be sealed with approved watertight glands, maintaining the integrity of the bulkhead. Cement or other improvised sealing is not acceptable, and alterations should be recorded for verification at survey.
✗
Question 34. What do SOLAS and the related standards require regarding VHF transmitter power?
Your Answer: (Not answered)
Correct Answer: C (Power adequate for the required range, with adjustable power for close and longer range communication)
💡 SOLAS and the Radio Regulations require VHF equipment to have adequate power, normally not exceeding 25 watts, with adjustment available: low power close to shore to reduce interference and high power for longer range.
✗
Question 35. What is the role of the designated person ashore under the ISM Code?
Your Answer: (Not answered)
Correct Answer: D (To monitor the safety and pollution prevention aspects of the ship's operation and ensure adequate resources and shore support)
💡 ISM Code 4 requires the company to designate a person or persons ashore to monitor the safety and pollution prevention aspects of the operation of each ship and to ensure adequate resources and shore support are provided, acting as the link between company and ship.
✗
Question 36. Each ship shall carry at least how many sets of firefighter's outfits?
Your Answer: (Not answered)
Correct Answer: C (2)
💡 SOLAS II-2/10: each ship shall carry at least two sets of firefighter's outfits.
✗
Question 37. What does SOLAS address regarding automatic closing devices on air pipes?
Your Answer: (Not answered)
Correct Answer: C (Automatic closing devices must be fitted, closing and remaining effective under the impact of sea water)
💡 SOLAS and the Load Line Convention require air pipes to be fitted with automatic closing devices that close and remain effective under the impact of water shipped on deck, preventing sea water from entering the tanks. A manual device alone would fail unnoticed.
✗
Question 38. What does SOLAS require for the display of the rudder angle indicator on the bridge?
Your Answer: (Not answered)
Correct Answer: D (It must display the actual rudder angle, and on larger ships also at the emergency steering position)
💡 SOLAS requires a rudder angle indicator on the bridge showing the actual rudder angle, so the helmsman can confirm the true position of the rudder. Showing the order only or an inaccurate indication leads to steering errors.
✗
Question 39. The storage medium of a VDR shall be:
Your Answer: (Not answered)
Correct Answer: C (shock-resistant, fire-resistant and penetration-resistant for later recovery)
💡 SOLAS V/20: the VDR storage medium shall be shock-resistant, fire-resistant and penetration-resistant for later recovery.
✗
Question 40. The intermediate verification of a Safety Management Certificate shall be carried out:
Your Answer: (Not answered)
Correct Answer: A (around the mid-point of the certificate's validity)
💡 SOLAS IX/4 (ISM) requires intermediate verification around the mid-point of the SMC validity.
✗
Question 41. What does SOLAS V/19 require of the rudder angle indicator on the bridge?
Your Answer: (Not answered)
Correct Answer: A (It must show the actual rudder angle, not merely the ordered angle)
💡 SOLAS V/19 requires a rudder angle indicator on the bridge showing the actual rudder angle, so that the helmsman can confirm the rudder has moved as ordered. Indicating the order alone is inadequate.
✗
Question 42. What does SOLAS address regarding ventilation of paint and flammable liquid lockers?
Your Answer: (Not answered)
Correct Answer: C (Independent mechanical ventilation capable of effectively removing flammable vapour)
💡 SOLAS requires paint and flammable liquid lockers to have independent mechanical ventilation effectively removing flammable vapour, preventing accumulation and ignition. Sharing ventilation with accommodation would carry toxic vapour into the living spaces.
✗
Question 43. What does SOLAS and the Polar Code require regarding manning and training for polar waters?
Your Answer: (Not answered)
Correct Answer: A (The master and officers in charge of a navigational watch must have completed appropriate polar waters training and gained the required experience)
💡 SOLAS XIV and STCW require the master and officers in charge of a navigational watch of a ship in polar waters to have completed polar waters training appropriate to the ship's category and to have the prescribed seagoing experience, ensuring the ability to operate in polar conditions.
✗
Question 44. What is required regarding problems found at a renewal survey before a new certificate is issued?
Your Answer: (Not answered)
Correct Answer: D (All matters affecting issue must be resolved before issue, or accepted by the Administration with conditions recorded)
💡 SOLAS requires matters found at a renewal survey which affect the issue of the certificate to be resolved before issue, or accepted by the Administration with restrictions or additional requirements recorded after assessment. Issuing with the problem outstanding leaves the certificate inconsistent with the actual condition.
✗
Question 45. A cargo ship has lost all main power and is on the emergency generator. Under SOLAS II-1/42, for how long must emergency lighting be maintained on a cargo ship?
Your Answer: (Not answered)
Correct Answer: B (18 hours)
💡 Emergency lighting must be maintained for 18 hours on cargo ships and 36 hours on passenger ships. Three hours is the minimum duration for the electric safety lamp of a firefighter's outfit — the two figures are easily confused.
✗
Question 46. What must the VDR record?
Your Answer: (Not answered)
Correct Answer: B (Position, course, speed, radar images, bridge audio and alarms)
💡 SOLAS requires the VDR to record data relevant to investigation, including date and time, position, course, speed, radar images with AIS, bridge audio, alarms and rudder orders, enabling the navigation and operation at the time to be reconstructed.
✗
Question 47. What do SOLAS and the related handbooks recommend for contact between survival craft after abandonment?
Your Answer: (Not answered)
Correct Answer: B (Maintain contact by two-way VHF, whistle or light and act together so as to be found more easily)
💡 SOLAS and the survival craft handbooks recommend that craft maintain contact by two-way VHF, whistle or light after abandonment, keeping together or close, acting in a coordinated way and conserving energy and supplies, improving the chance of detection by rescuers.
✗
Question 48. What lighting shall survival craft have?
Your Answer: (Not answered)
Correct Answer: B (Their own searchlight and light for night operation)
💡 Survival craft shall be provided with their own lighting for night operation.
✗
Question 49. What control is required over the effect of drills on navigation?
Your Answer: (Not answered)
Correct Answer: B (Drills should not impair the normal navigational watch and the safety of the ship, and may be held in batches or postponed if necessary)
💡 SOLAS and good practice require the timing of drills to have regard to safety of navigation. In confined waters, heavy weather or when full attention to manoeuvring is needed, drills may be held in batches or postponed, avoiding the loss of essential watchkeeping strength when everyone is mustered.
✗
Question 50. What are the requirements for keeping a radio log?
Your Answer: (Not answered)
Correct Answer: C (Distress, urgency and safety communications and equipment tests must be recorded as required)
💡 SOLAS IV/17 requires a radio log recording distress and safety communications, equipment tests and significant events, for use at surveys and in casualty investigation.
✗
Question 51. What is the purpose of the cargo securing manual in a PSC inspection?
Your Answer: (Not answered)
Correct Answer: C (To give the crew the correct securing methods and strength criteria for cargo units)
💡 SOLAS VI/5 and the CSS Code require a cargo securing manual specifying securing methods and strength criteria for cargo units, which the crew use to arrange and check the securing.
✗
Question 52. The second officer drafts the quarterly drill plan: "muster monthly, brief on the equipment, everyone to the station, no boat actually lowered." Measured against the SOLAS chapter III drill frequencies, what is missing?
Your Answer: (Not answered)
Correct Answer: A (every lifeboat should be launched with its assigned crew at intervals not exceeding 3 months and manoeuvred with them, and launched with at least two crew at intervals not exceeding 6 months)
💡 The frequencies are easy to mix up: launching with the assigned crew and manoeuvring at intervals within 3 months, launching with two or more crew within 6 months. The monthly abandon-ship and fire drill is a separate layer and neither substitutes for the other, and an annual survey of the appliances says nothing about the crew's ability to get the boat down.
✗
Question 53. What is the scope of SOLAS II-1?
Your Answer: (Not answered)
Correct Answer: A (Construction of ships to which the Convention applies, including subdivision, stability and machinery and electrical installations)
💡 SOLAS II-1 covers construction including subdivision, stability and machinery and electrical installations. Fire protection is Chapter II-2 and life-saving appliances Chapter III.
✗
Question 54. Portable fire extinguishers in machinery spaces shall be:
Your Answer: (Not answered)
Correct Answer: A (at least one near each hydrant and sufficient in total for the space)
💡 SOLAS II-2/10 requires at least one portable extinguisher near each hydrant, with sufficient total number.
✗
Question 55. A PSCO checked the gyro compass error. What does SOLAS and the related standards require of the gyro compass?
Your Answer: (Not answered)
Correct Answer: C (It must indicate true north steadily with the error within the prescribed limits while the ship is under way)
💡 SOLAS V/19 requires the gyro compass to indicate true north steadily within prescribed error limits while the ship is under way and rolling, with regular checks and records during the voyage.
✗
Question 56. Under the ISPS Code, which security level indicates the highest threat, i.e. a security incident is probable or imminent?
Your Answer: (Not answered)
Correct Answer: C (Level 3)
💡 SOLAS XI-2/3: under the ISPS Code, security level 3 indicates that a security incident is probable or imminent.
✗
Question 57. What is required when checking the lighting at survival craft embarkation positions?
Your Answer: (Not answered)
Correct Answer: A (Confirm that the emergency lighting operates, covering the embarkation area and the water alongside)
💡 SOLAS requires the lighting of the embarkation stations, survival craft stowage positions and the water alongside, including emergency lighting, to be confirmed in working order and covering the required area, so that abandonment at night is adequately lit. An appearance check would not confirm availability during a blackout.
✗
Question 58. The oil discharge monitoring equipment (ODM) is found not to have recorded as required during the voyage. The finding is?
Your Answer: (Not answered)
Correct Answer: B (The ODM must continuously monitor and record as required; failure to record is an operational and record deficiency)
💡 A tanker oil discharge monitoring equipment should continuously monitor the discharge and record the quantity discharged and the instantaneous rate as proof of a compliant discharge. Failure to record makes compliance unprovable. It is an operational and record deficiency to be corrected.
✗
Question 59. What does SOLAS address regarding earthing of the ship's electrical system?
Your Answer: (Not answered)
Correct Answer: B (Earth fault detection and protection must be provided to avoid electric shock and electrical fire)
💡 SOLAS requires means for earth fault detection and protection in the ship's electrical system, detecting insulation deterioration or earth faults in good time and preventing electric shock and electrical fire.
✗
Question 60. What does 'Company' mean in SOLAS?
Your Answer: (Not answered)
Correct Answer: A (The shipowner or an organization which has assumed responsibility for operation)
💡 It means the owner or any organization which has assumed responsibility for the ship's operation.
✗
Question 61. How must the loading instrument of a bulk carrier be used?
Your Answer: (Not answered)
Correct Answer: B (Compute strength and stability for the planned sequence before cargo work and monitor continuously during it)
💡 SOLAS requires the approved loading instrument to be used to compute hull strength and stability at each stage of the planned sequence before cargo work, with continuous monitoring during the operation and updating as it progresses, preventing excessive stress at any stage. Computing only at the end cannot prevent damage during the work.
✗
Question 62. What is required for the battery of the satellite EPIRB as to service and replacement?
Your Answer: (Not answered)
Correct Answer: A (It must be within its specified life, normally replaced at not more than five years or as the maker specifies)
💡 The battery of the EPIRB must be within its specified life, normally replaced at not more than five years, or as marked by the maker, so that it can transmit for the required period in a distress. Use beyond its life leaves the beacon's reliability unassured and is a deficiency to be corrected.
✗
Question 63. What expansion ratio is generally required for a tanker deck foam system?
Your Answer: (Not answered)
Correct Answer: C (Not exceeding about 12)
💡 The expansion ratio shall generally not exceed about 12.
✗
Question 64. How often must inflatable liferafts be serviced under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (At intervals not exceeding 12 months at an approved servicing station)
💡 SOLAS requires inflatable liferafts to be serviced at intervals not exceeding 12 months at an approved servicing station, while rigid lifeboats are subject to the prescribed annual inspection. The crew cannot replace the approved servicing.
✗
Question 65. What do SOLAS and good practice address regarding emergency stopping of the main engine?
Your Answer: (Not answered)
Correct Answer: C (Means for emergency stopping must be provided on the bridge and in the machinery space, operable rapidly in an emergency)
💡 SOLAS and good practice require means for emergency stopping of the main engine, operable quickly from the bridge or the machinery space, preventing an incident from escalating when the propeller is fouled, a person is in the water nearby, or machinery behaves abnormally.
✗
Question 66. What is the required interval for emergency steering drills?
Your Answer: (Not answered)
Correct Answer: C (At least once every three months)
💡 Under SOLAS III/19 emergency steering drills should be held at least once every three months. The drill makes the crew familiar with the procedures and communications for changing to the emergency steering gear when the main steering fails, and is a key emergency preparedness item.
✗
Question 67. Means of escape shall:
Your Answer: (Not answered)
Correct Answer: D (be continuous to the embarkation deck or muster station)
💡 SOLAS II-2/13 requires continuous means of escape to the embarkation deck or muster station.
✗
Question 68. What operational requirement relates to ballast water and SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Ballasting according to stability and strength requirements, preventing excessive hogging or sagging and insufficient stability)
💡 Ballast operations must follow stability and strength requirements so the ship keeps an appropriate draught, trim and stability. Excessive ballast or a poor sequence overstresses the hull, so the loading plan must be followed.
✗
Question 69. Ships engaged on international voyages shall be fitted with a gyro-compass. The number required is generally:
Your Answer: (Not answered)
Correct Answer: A (one (two may be required above 1 000 GT))
💡 SOLAS V/19: ships on international voyages shall be fitted with a gyro-compass; two may be required above 1 000 GT.
✗
Question 70. Under what conditions must machinery operate according to the relevant SOLAS provisions on list and trim?
Your Answer: (Not answered)
Correct Answer: A (It must operate normally under the prescribed angles of heel, trim and rolling)
💡 SOLAS requires main and auxiliary machinery and emergency equipment to operate normally under the prescribed angles of heel, trim and rolling, ensuring power and emergency capability in heavy weather.
✗
Question 71. What does SOLAS require for air pipes and sounding pipes passing through watertight bulkheads?
Your Answer: (Not answered)
Correct Answer: A (Reliable means of closing and sealing must be provided to maintain watertight integrity)
💡 SOLAS requires reliable closing and sealing arrangements for air and sounding pipes crossing watertight bulkheads, maintaining watertight integrity. Open ends or a deck cap alone are not sufficient.
✗
Question 72. What is the particular danger of a cargo leak on a gas carrier?
Your Answer: (Not answered)
Correct Answer: A (The cargo is often cryogenic, flammable or toxic; a leak vaporises rapidly and may form a flammable or toxic cloud)
💡 Gas carrier cargoes such as LPG and LNG are cryogenic, flammable, explosive or toxic. A leak vaporises rapidly and mixes with air to form a flammable or toxic cloud which may flash or explode on contact with a source of ignition, so the response must be by trained personnel.
✗
Question 73. If the master finds a defect affecting safe navigation that cannot be repaired on board, the first action is to:
Your Answer: (Not answered)
Correct Answer: A (Report to the Company and arrange repair)
💡 The master should report to the Company so that repair can be arranged and the voyage adjusted.
✗
Question 74. How many hand flares must each survival craft carry?
Your Answer: (Not answered)
Correct Answer: A (Six)
💡 SOLAS III requires six hand flares in each survival craft, in addition to the four rocket parachute flares required separately. The two numbers are different.
✗
Question 75. What nautical publications must be carried under SOLAS V/27?
Your Answer: (Not answered)
Correct Answer: B (Sailing directions, lists of lights and fog signals, tide tables and notices to mariners as required for the voyage)
💡 SOLAS V/27 requires all nautical publications necessary for the voyage, including sailing directions, lists of lights, tide tables and notices to mariners, kept corrected. Charts alone do not satisfy the requirement.
✗
Question 76. What radio communication measures are required when operating in polar regions?
Your Answer: (Not answered)
Correct Answer: A (Take account of limited satellite coverage and provide means such as HF unaffected by the region, with enhanced watchkeeping)
💡 Geostationary satellite coverage is limited in polar regions, above about 75 degrees latitude, so SOLAS and the Polar Code require means such as HF communication to be provided with a watch maintained and, where necessary, relaying through a coast station or another ship, ensuring that distress communication gets through.
✗
Question 77. What does SOLAS address regarding the fire and weathertight requirements for ventilators?
Your Answer: (Not answered)
Correct Answer: D (Closing devices must be fitted, able to shut off ventilation when required and maintain weathertightness)
💡 SOLAS requires ventilators to have closing devices that both shut off ventilation to control a fire and maintain weathertightness against the entry of sea water. A rain hood alone meets neither requirement.
✗
Question 78. What does the ISM Code address regarding the link between drills and incident reporting?
Your Answer: (Not answered)
Correct Answer: D (Problems revealed in drills should be analysed and used for improvement, together with accident and near-miss reporting)
💡 ISM Code 9 requires non-conformities, accidents and hazardous occurrences to be investigated and analysed with corrective action. Problems revealed in drills should likewise be analysed and used for improvement, serving as a basis for raising the standard of safety management.
✗
Question 79. Navigation equipment shall be capable of operating:
Your Answer: (Not answered)
Correct Answer: C (with an independent supply if the main and emergency sources fail)
💡 SOLAS V/19: navigation equipment shall have an independent supply where the main and emergency sources of electrical power fail.
✗
Question 80. What is required for the first aid kit in a lifeboat?
Your Answer: (Not answered)
Correct Answer: C (A first aid kit of the prescribed type with medicines within their expiry dates)
💡 SOLAS requires a lifeboat to carry a first aid kit of the prescribed type with the contents within their expiry dates. Out-of-date medicines may be ineffective after abandonment and are a common deficiency at inspection.
✗
Question 81. In sea area A4, on what equipment does distress communication principally rely?
Your Answer: (Not answered)
Correct Answer: D (MF/HF radio equipment with DSC, radiotelephony and NBDP)
💡 Sea area A4 lies beyond satellite coverage, so distress communication relies principally on MF/HF equipment with DSC, radiotelephony and narrow-band direct printing telegraphy. This is why HF equipment is required in A4.
✗
Question 82. What is required on completion of a job?
Your Answer: (Not answered)
Correct Answer: B (Clear the site, restore equipment and guards, close the permit and keep records)
💡 On completion of a job the site should be cleared of oil, debris and tools, the guards and safety devices removed for access restored, such as rails, gratings and covers, the permit closed and the persons and tools accounted for, with the completion recorded, preventing hazards from being left behind.
✗
Question 83. What does SOLAS require regarding operating instructions and illustrations for life-saving appliances?
Your Answer: (Not answered)
Correct Answer: C (Instructions and illustrations posted at the survival craft in the working language of the ship or English)
💡 SOLAS requires operating instructions and clear illustrations, such as the steps for lowering, releasing and starting the engine, to be posted at the survival craft in the working language of the ship or in English, so that the crew can act quickly from the diagram in an emergency.
✗
Question 84. What is the purpose of the bilge system?
Your Answer: (Not answered)
Correct Answer: D (Draining water from any watertight compartment)
💡 The bilge system shall be capable of draining any watertight compartment.
✗
Question 85. The master shall report:
Your Answer: (Not answered)
Correct Answer: C (dangerous conditions such as ice, derelicts or other hazards to navigation)
💡 SOLAS V/31 requires the master to report dangerous conditions such as ice, derelicts or other hazards.
✗
Question 86. The carriage of dangerous chemicals in bulk shall follow:
Your Answer: (Not answered)
Correct Answer: B (the International Bulk Chemical Code (IBC Code))
💡 SOLAS VII/7: the carriage of dangerous chemicals in bulk shall follow the IBC Code.
✗
Question 87. A cargo ship has lifeboats on one side and liferafts on the other. What is the basic requirement of SOLAS?
Your Answer: (Not answered)
Correct Answer: A (The survival craft capacity on each side must accommodate all persons on board)
💡 SOLAS requires that, whether lifeboats or liferafts are used, the capacity on each side accommodates all persons on board, so everyone can escape if one side is unavailable.
✗
Question 88. What does SOLAS III/19 require regarding lifeboats in abandon ship drills?
Your Answer: (Not answered)
Correct Answer: A (At least once every three months the boat is to be launched, and where reasonable and practicable lowered to the water and manoeuvred)
💡 SOLAS III/19 requires launching drills at least every three months, with the boat, where reasonable and practicable, lowered into the water and manoeuvred at least once in that period.
✗
Question 89. During steering gear trials in port the change-over of power units between the machinery control room and the bridge was found unsatisfactory. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (Change-over of power shall be capable of being effected quickly from the bridge or the steering gear compartment)
💡 SOLAS II-1/35-1 requires that change-over of the steering gear power units be effected quickly, either from the bridge or from the steering gear compartment, so control can be restored rapidly.
✗
Question 90. A Ship Security Alert System (SSAS) is intended to:
Your Answer: (Not answered)
Correct Answer: B (transmit a security alert to the competent authority indicating the ship's identity and position)
💡 SOLAS XI-2/6: a Ship Security Alert System transmits a security alert, indicating the ship's identity and position, to the competent authority.
✗
Question 91. What is sea area A1?
Your Answer: (Not answered)
Correct Answer: D (An area within coverage of at least one VHF coast station)
💡 An area within coverage of at least one VHF coast station with DSC.
✗
Question 92. What rescue preparation is required for enclosed space entry?
Your Answer: (Not answered)
Correct Answer: A (Rescue equipment including breathing apparatus and a lifting harness must be ready with personnel standing by, not sought at the time)
💡 Before entering an enclosed space, rescue equipment such as self-contained breathing apparatus, a harness and lifting line and a stretcher must be ready with personnel standing by, so that rescue can begin at once if something goes wrong. Seeking equipment at the time is a principal cause of multiple fatalities.
✗
Question 93. What measures do SOLAS and the IMSBC Code require for solid bulk cargoes liable to self-heat or release harmful gas?
Your Answer: (Not answered)
Correct Answer: A (Obtain full cargo information before loading, increase ventilation and gas testing and restrict entry into the holds)
💡 The IMSBC Code requires precautions for cargoes liable to self-heat or release harmful gas: full cargo information, increased ventilation and gas testing, restricted entry into the holds and emergency preparation, preventing spontaneous combustion, poisoning or explosion.
✗
Question 94. What is the basic requirement for cargo carriage under SOLAS VI?
Your Answer: (Not answered)
Correct Answer: D (Cargo shall be loaded, stowed and secured with regard for stability and structural strength)
💡 Loading, stowage and securing shall not endanger the ship's safety or stability.
✗
Question 95. What information must the master have before departure?
Your Answer: (Not answered)
Correct Answer: B (Approved stability information including damage stability)
💡 Approved stability information, including damage stability, shall be available to the master.
✗
Question 96. What structural condition should be confirmed before loading a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (The condition of hatch covers and coamings, deformation or corrosion of the internal structure and leakage of the double bottom and piping)
💡 Before loading a bulk carrier the condition of the hatch covers and coamings should be confirmed sound, the internal structure and stiffening free of serious deformation or corrosion and the double bottom and ballast piping free of leakage, with the bilges draining properly. These bear directly on the safety of loading and the structural integrity of the voyage.
✗
Question 97. Under SOLAS V/8, what follows from a breach of the regulations?
Your Answer: (Not answered)
Correct Answer: A (Responsibility follows and regard shall be had to navigational dangers)
💡 Responsibility follows and regard shall be had to navigational dangers.
✗
Question 98. What does SOLAS address regarding fire protection of the cargo pump room on a tanker?
Your Answer: (Not answered)
Correct Answer: D (Class A divisions at its boundaries with a fixed extinguishing system and fire detection inside)
💡 SOLAS requires the boundaries of a cargo pump room on a tanker to be class A divisions, with a fixed extinguishing system, normally CO2 or foam, and fire detection inside, since the pump room is a high risk space for accumulation and explosion of vapour.
✗
Question 99. What loading limitation must be observed when a bulk carrier loads high density cargo?
Your Answer: (Not answered)
Correct Answer: D (Limits on the maximum weight in each hold and on differences between adjacent holds, preventing excessive local stresses)
💡 Concentrated high density cargo overstresses the tank top and double bottom. SOLAS and the IMSBC Code require limits on the maximum weight per hold and on differences between adjacent holds to be observed. Limiting deadweight alone does not protect the structure.
✗
Question 100. What is the purpose of the boat hook among the lifeboat equipment?
Your Answer: (Not answered)
Correct Answer: A (To pull or push the boat when coming alongside, recovering floating objects or landing)
💡 The boat hook is used to pull or push the boat when coming alongside, recovering floating objects or landing, a common handling tool whose absence reduces the boat's handling and rescue capability.