Question 80. Who first knows that something is wrong with the machinery?
Your Answer:
(Not answered)
Correct Answer:
B (the watchkeeper and those walking the rounds - whether they report and when decides whether the intervention comes before or after the failure)
💡 The first signs of a fault are usually with the watch, in the eye, ear and hand: temperature, vibration, a smell, a weep, a change of note. Whether they report and how quickly settles whether intervention falls before the failure or after it. What the system therefore has to supply is not feeling but a standard to judge by - the round sheet, the parameter limits - a report route that costs little to use, and an answer that shows the report went somewhere; after twice of reporting into silence nobody reports. An alarm covers only the quantities it was designed to see, and a sensor drifting or a part wasting below its threshold makes no sound. The monthly return shows averages, which is exactly the data that smooths an anomaly away.