Question 1. What is meant by the requirement that drills be real?
Your Answer: (Not answered)
Correct Answer: B (the movements actually made to the station bill and the record written as it happened, the object being to test ability and lay bare the procedure)
💡 A drill is worth what it exposes: whether the gear works, whether the communications link, whether each hand knows where to go and what to do, whether the procedure still holds under pressure. None of that shows on paper, so the movements on the station bill are to be made and the record written as it happened, with the time, those present, the faults found and what was done about them. A completed form standing over a simplified exercise, or an office writing the record for the ship, throws away the only chance to test ability and mend the procedure, and when the alarm is genuine the crew is left to find out then. Audits and port State officers commonly start from whether the record is true, and a record that does not square with the equipment or the dates of testing points to something wider than the drill.
✗
Question 2. What should be done about failed lighting in an escape route?
Your Answer: (Not answered)
Correct Answer: D (Repair or replace promptly; lighting in escape routes is vital for emergency evacuation)
💡 Lighting in escape routes, including emergency and low level lighting, is essential for evacuation in fire and dense smoke. Failed fittings must be repaired or replaced promptly; their absence greatly increases the difficulty of evacuation and the risk of casualties.
✗
Question 3. After overhaul of launching appliances, what further test does SOLAS III/35 require?
Your Answer: (Not answered)
Correct Answer: A (A load test with the full complement at intervals of not more than five years)
💡 SOLAS III/35 requires that launching appliances be subjected to a test with the full complement on board at intervals of not more than five years, to verify performance under rated load.
✗
Question 4. What are the main items checked when an inflatable liferaft is serviced?
Your Answer: (Not answered)
Correct Answer: B (Tightness of the raft, the inflation system, the equipment, the weak link and the hydrostatic release unit)
💡 Servicing an inflatable liferaft covers a tightness test, the inflation system including cylinder pressure and valves, the completeness and expiry of the equipment and the condition of the weak link and hydrostatic release unit. Failure of any of these would affect use after abandonment.
✗
Question 5. What is the purpose of the weak link in a liferaft arrangement?
Your Answer: (Not answered)
Correct Answer: D (To part once the raft has inflated and floats, freeing it from the sinking ship)
💡 The weak link has a designed breaking strength so that it parts once the raft has inflated and is lifted by the water, freeing it from the sinking ship. If too strong the raft may be dragged under; if too weak it may part before inflation.
✗
Question 6. What is required for the display of alarms from a fixed fire detection and fire alarm system?
Your Answer: (Not answered)
Correct Answer: A (The alarm must be displayed on the bridge or at a continuously manned central control station and indicate the space concerned)
💡 SOLAS requires fire alarms to be displayed on the bridge or at a continuously manned central control station and to indicate the space in which the alarm was initiated, so the fire can be located at once.
✗
Question 7. What records and reporting are required for injury and illness?
Your Answer: (Not answered)
Correct Answer: B (Record the time, symptoms, treatment given and outcome and report to the company as required, including for work injuries)
💡 An injury or illness on board should be recorded with the time, how it happened, the symptoms, the first aid and treatment given, the outcome and the follow-up, and reported to the company as the system and regulations require, promptly for a work related injury, occupational disease or serious illness, providing a basis for claims and improvement.
✗
Question 8. Within an emission control area, what is the sulphur limit of fuel oil used on board?
Your Answer: (Not answered)
Correct Answer: A (0.10 per cent m/m)
💡 Within an emission control area the sulphur limit of fuel oil used on board is 0.10 per cent m/m. The ship should be able to show compliance through bunker delivery notes, changeover procedures and records, and should allow sufficient changeover time before entering the area.
✗
Question 9. Life-saving appliances are kept on a planned maintenance schedule. How are the weekly and monthly checks divided?
Your Answer: (Not answered)
Correct Answer: C (weekly testing of the general alarm and of lighting at muster and embarkation stations, monthly examination of all appliances with their equipment confirmed complete and recorded)
💡 The Convention separates the two by object: weekly, the general emergency alarm system and the emergency lighting at muster and embarkation stations are tested; monthly, all life-saving appliances are examined, boats, rafts, their equipment, launching arrangements and engines being confirmed ready for immediate use, with defects logged. Shrinking the monthly check to one pass before the annual survey, or leaving rafts out of the ship's duties, is how equipment turns up missing when it is wanted.
✗
Question 10. What is required for speed control when navigating in restricted visibility?
Your Answer: (Not answered)
Correct Answer: A (Proceed at a safe speed, that is a speed allowing timely stopping or avoidance in the visibility prevailing)
💡 COLREG Rules 6 and 19 require a safe speed in restricted visibility, being a speed at which appropriate and effective avoiding action can be taken and the vessel stopped within an appropriate distance, having regard to the visibility, traffic density and manoeuvrability.
✗
Question 11. What do SOLAS and the related conventions address regarding sewage treatment systems?
Your Answer: (Not answered)
Correct Answer: D (The plant must operate and discharge in accordance with the requirements, with attention to the risk of harmful gas)
💡 A sewage treatment plant must be operated and discharge in accordance with MARPOL, and attention paid to the harmful gases which may be produced in the process. The relevant spaces should be ventilated, entry restricted and testing carried out as prescribed to prevent poisoning.
✗
Question 12. Which aspects must the ship's electrical system be protected against under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (Short circuit, overload and earth fault, preventing electrical fire and equipment damage)
💡 SOLAS requires protection against short circuit, overload and earth fault to prevent electrical fire, equipment damage and electric shock. A single type of protection is not enough.
✗
Question 13. The muster list shall be posted:
Your Answer: (Not answered)
Correct Answer: D (in conspicuous places on board, especially the bridge, machinery spaces and accommodation)
💡 SOLAS III/37 requires the muster list to be posted in conspicuous places, including the bridge, machinery spaces and accommodation.
✗
Question 14. How must the expiry date of distress signals be managed?
Your Answer: (Not answered)
Correct Answer: D (Check expiry dates periodically and replace expired signals, which may fail or be dangerous)
💡 Distress signals have a definite expiry date and should be checked periodically with expired ones replaced. An expired signal may fail to ignite or behave abnormally, such as premature burning or insufficient height, and failure when genuinely needed endangers life. It is a common deficiency at inspection.
✗
Question 15. What do SOLAS and the IMSBC Code address regarding trimming of solid bulk cargo?
Your Answer: (Not answered)
Correct Answer: B (Cargo should be trimmed to reduce the risk of shifting and heeling, with special trimming required for certain cargoes)
💡 SOLAS and the IMSBC Code require trimming according to the nature of the cargo, distributing it evenly and reducing shifting and heeling during the voyage. Certain cargoes such as those liable to liquefy have specific trimming requirements, and failure to trim can lead to cargo shift and capsize.
✗
Question 16. The crew rest hour records are found clearly inconsistent with the watchkeeping arrangements. The finding is?
Your Answer: (Not answered)
Correct Answer: C (Rest hours must be truthfully recorded and meet the minimum; inconsistency is a violation)
💡 Crew rest hours should meet the minimum requirements and be truthfully and completely recorded. Inconsistency with the watchkeeping arrangements may conceal insufficient rest and endanger the safety of watchkeeping. It is a deficiency against the rest hour rules to be investigated and corrected.
✗
Question 17. What does a B-15 class division mean?
Your Answer: (Not answered)
Correct Answer: D (It prevents the passage of flame and limits temperature rise for 15 minutes in the standard fire test)
💡 Class B divisions are graded B-15 and B-0, the figure being the period in minutes for which temperature rise is limited in the standard fire test. Class B divisions are of non-combustible material, preventing passage of flame with lower strength than class A.
✗
Question 18. How should life-saving appliances other than lifeboats and liferafts be distributed?
Your Answer: (Not answered)
Correct Answer: B (One full set on board and one at the shore establishment)
💡 SOLAS III/21: the quantity shall be sufficient to provide one set for all on board and one at the shore establishment.
✗
Question 19. Navigational notices received on board have not been applied for a long period. What does SOLAS V/27 require?
Your Answer: (Not answered)
Correct Answer: B (Charts and publications shall be adequate and kept up to date)
💡 SOLAS V/27 requires ships to carry and maintain adequate and up-to-date charts and nautical publications, corrected from notices to mariners. Failure to correct is a deficiency.
✗
Question 20. What do SOLAS and COLREG emphasise about radar use in restricted visibility?
Your Answer: (Not answered)
Correct Answer: D (Switch on the radar early, use the longer range scales, observe continuously and interpret echoes correctly)
💡 COLREG and SOLAS require the radar to be switched on early in restricted visibility, used on the longer range scales and observed continuously, supplementing visual look-out. Radar must never replace the look-out.
✗
Question 21. Passenger ships of 4 000 GT and above shall be provided with at least how many independently driven fire pumps?
Your Answer: (Not answered)
Correct Answer: B (3)
💡 SOLAS II-2/10 requires at least three independently driven fire pumps for passenger ships of 4 000 GT and above.
✗
Question 22. Rescue boat recovery appliances shall be capable of recovering the rescue boat with persons and equipment at ship's headway of up to:
Your Answer: (Not answered)
Correct Answer: B (5 knots)
💡 SOLAS III/16 requires recovery at ship's headway of up to 5 knots.
✗
Question 23. How many buoyant smoke signals shall each survival craft carry?
Your Answer: (Not answered)
Correct Answer: A (2)
💡 Two.
✗
Question 24. What is the maximum interval for servicing an inflatable liferaft?
Your Answer: (Not answered)
Correct Answer: C (12 months)
💡 SOLAS III/20: inflatable liferafts shall be serviced at an approved station at intervals not exceeding 12 months.
✗
Question 25. What do SOLAS V and COLREG require when navigating in a narrow channel?
Your Answer: (Not answered)
Correct Answer: A (Keep as near to the outer limit on the starboard side as is safe and practicable, at a safe speed with an adequate look-out)
💡 COLREG Rule 9 requires a vessel in a narrow channel to keep as near to the outer limit on her starboard side as is safe and practicable, at a safe speed with an adequate look-out. High speed or occupying any part of the channel greatly increases the risk of collision.
✗
Question 26. What does SOLAS address regarding class A divisions at the galley?
Your Answer: (Not answered)
Correct Answer: A (Class A divisions between the galley and adjacent accommodation, preventing spread of fire and fumes)
💡 SOLAS requires class A divisions between the galley and adjacent accommodation to prevent the spread of fire. Since the galley presents open flame and oil fire risks, inadequate separation would allow fire to reach the accommodation quickly.
✗
Question 27. How does the number of firefighter's outfits differ between tankers and ordinary cargo ships?
Your Answer: (Not answered)
Correct Answer: B (Tankers normally require four outfits, ordinary cargo ships two)
💡 SOLAS II-2/10.10 requires at least two firefighter's outfits on cargo ships of 1000 GT and above. Tankers must carry additional outfits, normally four in total, with extra breathing apparatus.
✗
Question 28. What should the safety training of crew cover?
Your Answer: (Not answered)
Correct Answer: B (Safety awareness, shipboard and job specific training, emergency duties and equipment operation, risk assessment and permit to work systems)
💡 The ISM Code and STCW require crew safety training to cover safety awareness, shipboard and job specific training including familiarisation with duties and equipment, emergency duties and the operation of life-saving and firefighting equipment, risk assessment and permit to work systems, with familiarisation arranged for newly joined and transferred personnel.
✗
Question 29. A fixed detection system was tested with smoke. What action must follow detection under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (An audible and visual alarm on the bridge or at the control station, indicating the space concerned)
💡 SOLAS requires detection to produce an audible and visual alarm on the bridge or at a continuously manned control station and to indicate the space involved. Automatic discharge is not necessarily required.
✗
Question 30. The watertight door indicator showed a door open while it was in fact closed. What is the finding?
Your Answer: (Not answered)
Correct Answer: B (A deficiency; the indicator must accurately reflect the actual status, as a false indication misleads the assessment of watertight integrity)
💡 The watertight door indicator on the bridge must accurately reflect the actual open or closed status. A false indication would lead the watchkeeper to a wrong appreciation of watertight integrity and to incorrect measures after damage, so it is a deficiency affecting safety.
✗
Question 31. What does SOLAS require regarding consistency between the muster list and the persons actually on board?
Your Answer: (Not answered)
Correct Answer: A (The muster list must match the persons actually on board and be updated and re-posted after crew changes)
💡 SOLAS requires the muster list to agree with the persons actually on board and to be updated and re-posted after changes, so that every crew member can find his duty. Using an out-of-date list leaves duties unclear in an emergency.
✗
Question 32. Radio antennas shall be so installed that they can operate:
Your Answer: (Not answered)
Correct Answer: A (under all weather conditions with adequate protection)
💡 SOLAS IV/13 requires radio antennas to operate under all weather conditions with adequate protection.
✗
Question 33. What should a maintenance programme for radio equipment include?
Your Answer: (Not answered)
Correct Answer: B (Daily checks, periodic tests, spares provision and repair arrangements, either ashore or on board)
💡 SOLAS requires the availability of radio equipment to be ensured by daily checks, periodic tests, spare parts and either a shore-based maintenance agreement or at-sea maintenance capability, with the maintenance programme reflecting these arrangements and verified at survey.
✗
Question 34. Each lifeboat shall be provided with equipment including:
Your Answer: (Not answered)
Correct Answer: B (a complete set including oars, compass, sea anchor, first-aid kit, etc.)
💡 SOLAS III/34 lists lifeboat equipment including oars, compass, sea anchor, first-aid kit, food and water.
✗
Question 35. What should be done if a problem is found with a breathing apparatus face mask?
Your Answer: (Not answered)
Correct Answer: B (Replace it if perished, damaged or not sealing, otherwise it leaks and the apparatus fails)
💡 A face mask that is perished, damaged or not sealing will let the wearer inhale toxic smoke and must be replaced at once. Repair by tape or other temporary means cannot ensure airtightness and is a deficiency affecting the safety of firefighters.
✗
Question 36. Which Code governs the construction of ships carrying dangerous chemicals in bulk?
Your Answer: (Not answered)
Correct Answer: D (The IBC Code)
💡 The IBC Code.
✗
Question 37. Regarding lifeboat provision for cargo ships, which is correct?
Your Answer: (Not answered)
Correct Answer: D (lifeboats for all persons on board shall be provided on each side)
💡 SOLAS III/31 requires lifeboats for all persons on each side of a cargo ship, or liferafts meeting equivalent conditions.
✗
Question 38. What is the purpose of the reference documents in a ship security plan, such as the security assessment report?
Your Answer: (Not answered)
Correct Answer: C (To provide the basis for the measures in the plan, showing the risks they address)
💡 The ISPS Code requires the ship security plan to contain reference documents such as the security assessment report, showing the risks that the measures in the plan address and the conclusions of the assessment, so that the measures are targeted. Without that basis the measures become a formality.
✗
Question 39. What does SOLAS address regarding brakes and limits on survival craft launching appliances?
Your Answer: (Not answered)
Correct Answer: A (Reliable brakes controlling the speed of lowering and holding the craft, with end limits provided)
💡 SOLAS requires launching appliances to have reliable brakes to control the speed of lowering and hold the craft, with end limits preventing over-running or release, protecting the persons on board.
✗
Question 40. What monitoring of cargo temperature and humidity is required?
Your Answer: (Not answered)
Correct Answer: D (Measure and record hold temperature and humidity periodically as the cargo requires, dealing with abnormal heating or condensation promptly)
💡 For cargoes liable to self-heat, heat or sensitive to moisture, such as coal, grain and certain chemicals, the hold temperature and humidity should be measured and recorded periodically, and abnormal temperature rise or condensation investigated, whether from self-heating or incorrect ventilation, with ventilation or other measures taken.
✗
Question 41. What does A-60 mean in the context of class A fire divisions?
Your Answer: (Not answered)
Correct Answer: B (That the division prevents passage of smoke and flame and limits temperature rise for 60 minutes in the standard fire test)
💡 Class A divisions are graded A-60, A-30, A-15 and A-0 by the duration for which they prevent passage of smoke and flame and limit temperature rise in the standard fire test. The number is a duration in minutes, not a thickness.
✗
Question 42. What are the approval and use requirements for the Cargo Securing Manual?
Your Answer: (Not answered)
Correct Answer: C (It should be approved by the Administration and carried on board, the crew securing cargo and inspecting the securing equipment as it requires)
💡 Under SOLAS V/5 and related requirements the relevant ships should carry a Cargo Securing Manual approved by the Administration, containing the list, strength, arrangement and use of the securing devices, the crew securing cargo as it requires and inspecting and maintaining the equipment at the required intervals, recording defects and repairs.
✗
Question 43. What radio communication measures are required when operating in polar regions?
Your Answer: (Not answered)
Correct Answer: A (Take account of limited satellite coverage and provide means such as HF unaffected by the region, with enhanced watchkeeping)
💡 Geostationary satellite coverage is limited in polar regions, above about 75 degrees latitude, so SOLAS and the Polar Code require means such as HF communication to be provided with a watch maintained and, where necessary, relaying through a coast station or another ship, ensuring that distress communication gets through.
✗
Question 44. What does SOLAS provide regarding combining different types of drill?
Your Answer: (Not answered)
Correct Answer: B (Drills of different kinds may be combined where reasonable and practicable, provided the objectives of each are met)
💡 SOLAS permits drills of different kinds, such as abandon ship and fire drills, to be combined where reasonable and practicable, provided that the training objectives of each are achieved. Combining must not mean omitting essential elements.
✗
Question 45. In what form shall the fire control plan be presented?
Your Answer: (Not answered)
Correct Answer: D (Plans, with symbols, showing divisions, control stations and fire-fighting appliances on each deck)
💡 Plans with standard symbols showing divisions, control stations and appliances on each deck.
✗
Question 46. What are the restrictions on non-protected portable equipment in tanker cargo tanks?
Your Answer: (Not answered)
Correct Answer: D (Equipment such as ordinary torches or non-protected radios may not be used where vapour may accumulate)
💡 Vapour may accumulate in the cargo tanks, pump room and adjacent spaces of a tanker, so equipment that may produce a spark, such as ordinary torches, non-protected radios, power tools and camera flashes, is prohibited. Intrinsically safe or explosion-protected equipment must be used.
✗
Question 47. Which describes the periodical survey under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (Carried out periodically and may replace an annual survey)
💡 The periodical survey may replace one of the annual surveys.
✗
Question 48. A PSC inspection found hydrant outlets in the machinery space that did not match the ship's hoses. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: A (All hydrant outlets and hose couplings must be interchangeable, with a uniform coupling standard)
💡 SOLAS requires hydrants, hoses and couplings to fit one another on a uniform standard, otherwise they cannot be assembled in a fire. A mixture of standards is a common ground for detention.
✗
Question 49. Speed and distance measuring equipment shall provide the bridge with:
Your Answer: (Not answered)
Correct Answer: C (speed and distance information over the ground)
💡 SOLAS V/19 requires speed and distance measuring equipment providing speed and distance over the ground.
✗
Question 50. How should fire hoses be used in a fire drill?
Your Answer: (Not answered)
Correct Answer: C (Use hydrants and hoses at designated positions under the drill plan to verify the system, avoiding waste and damage to equipment)
💡 In a fire drill, hydrants and hoses should be used at designated safe positions to verify hose connection, nozzle handling and supply pressure, giving the crew practical experience. After using substantial water, drainage and anti-slip measures should be taken and cargo and equipment protected.
✗
Question 51. A lifeboat shall be provided with at least how many hand flares?
Your Answer: (Not answered)
Correct Answer: B (6)
💡 SOLAS III/34 requires at least six hand flares in a lifeboat.
✗
Question 52. What do SOLAS and the IMDG Code require during loading and unloading of dangerous goods?
Your Answer: (Not answered)
Correct Answer: D (Fire prevention, spill prevention and personal protection measures, with working conditions controlled according to the cargo)
💡 SOLAS VII and the IMDG Code require fire and explosion prevention, spill prevention, personal protection and emergency preparedness during cargo work, with hold conditions such as temperature and ventilation controlled according to the cargo and the port informed and signs displayed as necessary.
✗
Question 53. When a lifeboat also serves as a rescue boat, what conditions must it satisfy under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (It must meet the requirements for a rescue boat in respect of rapid launching and recovery, speed and manoeuvrability)
💡 SOLAS requires a lifeboat serving as a rescue boat to meet all the rescue boat requirements for rapid launching and recovery, minimum speed and manoeuvrability. Labelling or adding equipment alone is not sufficient.
✗
Question 54. Which statement about immersion suits is correct?
Your Answer: (Not answered)
Correct Answer: C (immersion suits reduce body heat loss in cold water)
💡 SOLAS III/32 requires immersion suits for rescue boat crew to reduce body heat loss in cold water.
✗
Question 55. For a ship with no emergency generator, for how long shall the GMDSS reserve source of energy supply?
Your Answer: (Not answered)
Correct Answer: C (6 hours)
💡 SOLAS IV/13: the reserve source shall be capable of supplying for 6 hours on ships without an emergency generator.
✗
Question 56. What is the scope of the term 'ship' in SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Any ship engaged on international voyages, with exclusions such as warships and some small cargo ships)
💡 SOLAS applies to ships on international voyages, with stated exclusions for warships and certain small cargo ships.
✗
Question 57. Which statement about the purpose of spare navigation lights is correct?
Your Answer: (Not answered)
Correct Answer: A (They can be brought into use if a main navigation light fails, ensuring the required lights are continuously available)
💡 Under SOLAS V/19 and related requirements a ship may carry spare navigation lights, such as duplicate fittings or portable spare lights, to be brought into use if a main light fails, ensuring the required lights are continuously available. Their stowage and power supply should be kept ready for use.
✗
Question 58. Before proceeding to sea, the ship shall be:
Your Answer: (Not answered)
Correct Answer: A (ensured to be in all respects seaworthy, including adequate stability and trim)
💡 SOLAS V/34: before proceeding to sea the ship shall be ensured to be in all respects seaworthy, including adequate stability and trim.
✗
Question 59. From what source must the fire detection system be supplied after a blackout?
Your Answer: (Not answered)
Correct Answer: C (Automatic change-over to the emergency source, keeping detection working)
💡 SOLAS requires the fixed fire detection system to be supplied from the main and emergency sources with automatic change-over when the main source fails, so that detection continues to work and alarms are given during a blackout.
✗
Question 60. What is required for the repeaters of a gyrocompass and their alignment?
Your Answer: (Not answered)
Correct Answer: D (Repeaters should agree with the master compass and be aligned as required; if the error exceeds the limit the cause should be found and corrected)
💡 Under SOLAS V/19 and related requirements the repeaters of a gyrocompass should agree with the master compass and be checked against it at the required intervals, any error exceeding the limit being investigated and corrected, such as by adjusting the repeater or servicing the master compass. The reliability of the heading reference directly affects navigational safety.
✗
Question 61. Indication of propeller pitch and speed shall show:
Your Answer: (Not answered)
Correct Answer: B (pitch (where applicable), propeller speed and direction of rotation)
💡 SOLAS V/19: the bridge shall be provided with indicators for pitch (where applicable), propeller speed and direction of rotation.
✗
Question 62. How should medical advisory services be used?
Your Answer: (Not answered)
Correct Answer: B (Contact a shore-based medical advisory service by radio or satellite for guidance when a crew member is ill or injured)
💡 SOLAS and the MLC require the ship to contact a shore-based medical advisory service such as a TMAS by radio, satellite or other means for professional guidance when needed, recording the consultation and the treatment given. Prompt advice on an ocean passage markedly improves the outcome.
✗
Question 63. What control is required over the effect of drills on navigation?
Your Answer: (Not answered)
Correct Answer: B (Drills should not impair the normal navigational watch and the safety of the ship, and may be held in batches or postponed if necessary)
💡 SOLAS and good practice require the timing of drills to have regard to safety of navigation. In confined waters, heavy weather or when full attention to manoeuvring is needed, drills may be held in batches or postponed, avoiding the loss of essential watchkeeping strength when everyone is mustered.
✗
Question 64. What is the most important requirement in the stowage and securing of a liferaft?
Your Answer: (Not answered)
Correct Answer: B (That it can be released very quickly)
💡 A liferaft must be capable of quick release; excessive chocking impedes access.
✗
Question 65. What do SOLAS and good practice address regarding the use of watertight doors to control heel after damage?
Your Answer: (Not answered)
Correct Answer: D (Act in accordance with the damage control information by isolating flooded compartments and, if necessary, counter-flooding to control heel)
💡 SOLAS requires action in accordance with the damage control information and booklet: isolating flooded compartments by closing watertight doors and valves, counter-flooding where necessary to reduce heel and assessing residual stability. Blind action may make the situation worse.
✗
Question 66. What is the emergency bilge suction for?
Your Answer: (Not answered)
Correct Answer: B (Dewatering the machinery space using the main engine cooling pump)
💡 It allows the machinery space to be dewatered using the main cooling or sea water pump.
✗
Question 67. What shall the design of the bridge windows ensure?
Your Answer: (Not answered)
Correct Answer: A (The officer on watch can see the forward seaway and the ship's vicinity)
💡 SOLAS V/22: the bridge must permit a good all-round view from the conning position.
✗
Question 68. For a cargo ship with a double bottom, the minimum height of the inner bottom above the top of the keel at midships shall be:
Your Answer: (Not answered)
Correct Answer: D (B/20 or 2 m, whichever is less)
💡 SOLAS II-1/6: the double bottom height shall be not less than B/20 and in no case less than 760 mm; in machinery spaces it may be reduced to B/20 or 2 m, whichever is less.
✗
Question 69. What length of fire hose does SOLAS II-2/10.2.3 require inside machinery spaces?
Your Answer: (Not answered)
Correct Answer: B (Not more than 15 m)
💡 SOLAS II-2/10.2.3 limits fire hoses in machinery spaces to 15 m; 20 m applies to other spaces and open decks. The two limits are frequently confused.
✗
Question 70. If a PSC deficiency involves the responsibility of a classification society, what does the port State do?
Your Answer: (Not answered)
Correct Answer: B (Notify the flag State and the recognised organisation, requiring follow-up and confirmation of rectification)
💡 Where a deficiency involves the responsibility of a classification society as a recognised organisation, the port State notifies the flag State and the organisation, requiring assessment and follow-up, such as an additional survey or rectification. This is the statutory notification mechanism between port State, flag State and recognised organisation.
✗
Question 71. What is required of the master during a PSC inspection?
Your Answer: (Not answered)
Correct Answer: B (Provide information truthfully and arrange for personnel to assist, without concealing deficiencies or obstructing the inspection)
💡 Port State control is a legal power. The master should provide certificates, records and information truthfully, arrange for the crew to assist and explain the situation truthfully. Concealing, falsifying or obstructing leads to escalation and even coercive measures and a higher risk profile for the ship.
✗
Question 72. What fire precautions apply during cargo operations on a tanker?
Your Answer: (Not answered)
Correct Answer: A (Control vapour emission, prohibit hot work and spark-producing operations and keep the inert gas and firefighting equipment available)
💡 During cargo operations on a tanker, vapour emission should be controlled, for example by recovery or discharge to a safe position, hot work and spark-producing operations such as hammering or the use of non-protected tools must be prohibited in the cargo area, and the inert gas system and firefighting equipment kept available.
✗
Question 73. What responsibility of the watchkeeper does SOLAS emphasise when ECDIS is in use?
Your Answer: (Not answered)
Correct Answer: A (Familiarity with the system and continuous monitoring and management of system alarms, without relaxing look-out or position fixing because of automation)
💡 SOLAS and STCW require the watchkeeper to be familiar with ECDIS and to monitor and manage its alarms continuously, maintaining manual position fixing and look-out. Automation is not a ground for relaxing vigilance.
✗
Question 74. What is required regarding the difference between indicated and actual rudder angle?
Your Answer: (Not answered)
Correct Answer: D (The difference must be within the permitted tolerance and corrected if exceeded)
💡 SOLAS and good seamanship require the difference between the indicated and actual rudder angle to be within the permitted tolerance. An excessive difference, such as more than five degrees, misleads the helmsman and the officer, and should be found and corrected at trials.
✗
Question 75. What does the Polar Code address regarding safety equipment for ships in polar waters?
Your Answer: (Not answered)
Correct Answer: B (Equipment suited to the polar environment for life-saving, firefighting, ice protection and emergencies)
💡 The Polar Code requires equipment suited to the polar environment, such as thermally protective life-saving appliances, firefighting equipment suitable for low temperature, ice protection and de-icing arrangements and emergency communication and escape means. Ordinary water equipment is not sufficient.
✗
Question 76. What is the requirement for lights carried in survival craft?
Your Answer: (Not answered)
Correct Answer: B (They must indicate the position of the craft in darkness, with self-igniting lights or torches as prescribed)
💡 SOLAS requires survival craft to carry means of indicating their position in darkness, including a self-igniting light or an approved electric torch, so that they can be found at night.
✗
Question 77. What are the duties of the deck watch during cargo operations on a tanker?
Your Answer: (Not answered)
Correct Answer: B (Monitor piping, valves and tanks, detecting leaks, overflow or abnormalities and taking action)
💡 During cargo operations on a tanker a deck watch must be maintained, monitoring pipeline joints for leakage, tank levels and pressures, overflow and unusual noise, with communication kept with the engine room and the terminal, so that abnormalities are detected and dealt with promptly.
✗
Question 78. What checking of lifeboat equipment is required in an abandon ship drill?
Your Answer: (Not answered)
Correct Answer: C (Check that it is complete, properly secured and not expired or damaged)
💡 An abandon ship drill should include checking that the lifeboat equipment is complete against the list, securely stowed and neither expired, such as pyrotechnics and medicines, nor damaged, with missing or expired items replenished, so that the boat is fully equipped when actually used.
✗
Question 79. What is the purpose of the emergency towing arrangement required on a tanker?
Your Answer: (Not answered)
Correct Answer: A (To enable the ship to be taken in tow quickly when the main engine or steering fails, reducing the risk of becoming a hazard)
💡 Under SOLAS II-1/3-4 a tanker should be provided with an emergency towing arrangement at the bow and stern so that it can be taken in tow quickly if the main engine or steering fails, reducing the risk of an accident and pollution when out of control in a busy or sensitive area. The arrangement should be capable of rapid deployment.
✗
Question 80. What should the radio personnel do when the abandon ship alarm is sounded?
Your Answer: (Not answered)
Correct Answer: D (Ensure a distress alert has been transmitted and maintain communication, taking portable radio equipment into the survival craft)
💡 On the abandon ship alarm, the personnel responsible for radio should ensure a distress alert has been sent with the position and nature of distress, attempt to establish communication and take the portable VHF and, where applicable, the EPIRB into the survival craft as prescribed, so that distress communication continues after abandonment.
✗
Question 81. Before the ship proceeds to sea, the voyage plan shall be prepared by:
Your Answer: (Not answered)
Correct Answer: B (the master)
💡 SOLAS V/34: the voyage plan shall be prepared before departure by the master.
✗
Question 82. What is required in requesting shore-based support?
Your Answer: (Not answered)
Correct Answer: C (Report needs for resources and support to the company promptly and follow them up, never lowering the standard because support is lacking)
💡 The ISM Code requires the ship to report its needs for resources and support, such as spares, technical guidance, training and additional personnel, promptly and to follow them up. The company should provide support within reason, and the ship must not operate at a reduced safety standard for a long period because support is lacking.
✗
Question 83. How many fire pumps are required on a passenger ship of 4000 GT and above?
Your Answer: (Not answered)
Correct Answer: D (Three)
💡 At least three.
✗
Question 84. A cargo ship shall be provided with at least how many rescue boats?
Your Answer: (Not answered)
Correct Answer: D (1)
💡 SOLAS III/31 requires cargo ships to be provided with at least one rescue boat.
✗
Question 85. What does SOLAS address regarding the watertight integrity of spaces above the bulkhead deck?
Your Answer: (Not answered)
Correct Answer: C (Openings must be fitted with effective closing appliances to prevent sea water entering the hull through them)
💡 SOLAS requires openings such as doors, side scuttles and ventilators above the bulkhead deck to have effective closing appliances, preventing sea water from entering the hull and causing loss of stability.
✗
Question 86. What launching and recovery time must a rescue boat achieve under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (Launch and recover within not more than 5 minutes in moderate sea conditions)
💡 SOLAS requires a rescue boat to be launched and recovered within not more than 5 minutes in moderate sea conditions, so that a person in the water is recovered as quickly as possible. A longer time significantly reduces the chance of success.
✗
Question 87. What communication procedure should be exercised in emergency steering drills?
Your Answer: (Not answered)
Correct Answer: D (Passing and confirming orders between the bridge and the steering gear compartment, ensuring communication works in an emergency)
💡 An emergency steering drill should include passing and repeating orders between the bridge and the steering gear compartment using the prescribed means, so that orders are accurate in an emergency. Practising the operation without the communication leaves a gap.
✗
Question 88. A PSCO checked the chart updating of ECDIS. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: D (Electronic charts must be kept up to date and consistent with the ENCs in use)
💡 SOLAS requires the electronic charts used in ECDIS to be kept corrected to the latest state and consistent with the ENCs in use. Late updating means missing recent navigational warnings and increases the risk of grounding, a common deficiency.
✗
Question 89. What preparation do SOLAS and BMP require before entering a high risk area?
Your Answer: (Not answered)
Correct Answer: C (Complete a security risk assessment, apply hardening and protective measures, conduct drills and report to the company, with reporting maintained)
💡 Before entering a high risk area a security risk assessment should be completed, protective and hardening measures applied in accordance with BMP, drills held, the company informed and reports made to the relevant bodies as required, so that the ship is prepared if threatened.
✗
Question 90. What does SOLAS and good seamanship recommend for shiphandling in heavy weather?
Your Answer: (Not answered)
Correct Answer: A (Adopt a course and speed that reduce rolling and slamming, reducing speed or altering course as necessary)
💡 Measures in heavy weather include choosing a course so the hull meets the seas at a suitable angle, avoiding a beam sea and direct head seas, and adjusting speed to reduce slamming and pitching, preventing cargo shift and structural damage. Full speed intensifies the stresses.
✗
Question 91. Which parameters should normally be tested before entry into an enclosed space?
Your Answer: (Not answered)
Correct Answer: B (Oxygen content, flammable gas and toxic gases such as hydrogen sulphide and carbon monoxide)
💡 Testing should cover oxygen content, flammable gas concentration and toxic gases, commonly hydrogen sulphide and carbon monoxide. Testing only one parameter may overlook a lethal hazard, and judging by smell is even less reliable.
✗
Question 92. What does SOLAS require regarding the marking of the rated capacity of survival craft?
Your Answer: (Not answered)
Correct Answer: B (It must be clearly marked on the craft and must not be exceeded)
💡 SOLAS requires the rated capacity to be clearly marked on the craft and not to be exceeded. Overloading seriously affects buoyancy and stability.
✗
Question 93. At the change of watch, which statement about what should be handed over is correct?
Your Answer: (Not answered)
Correct Answer: A (Course and speed, position, traffic situation, condition of the ship's equipment and existing risks and other essential information)
💡 The change of watch should ensure that the relieving officer takes responsibility with a full understanding of the situation, including course and speed, position and passage plan, traffic and intentions, equipment condition and alarms, weather and visibility, and existing risks and outstanding matters. A poor handover is a common cause of navigational accidents.
✗
Question 94. A fire hydrant in the engine room is found without its matching hose and nozzle. What should the finding be?
Your Answer: (Not answered)
Correct Answer: A (Firefighting equipment incomplete, a deficiency affecting firefighting capability, to be made good)
💡 Every fire hydrant should be provided at all times with a hose and nozzle so that firefighting can start promptly anywhere on board. Missing matching items makes that hydrant unusable. This is a deficiency of incomplete equipment affecting firefighting capability and should be made good before departure.
✗
Question 95. What is the stability concern when carrying grain in bulk?
Your Answer: (Not answered)
Correct Answer: B (Heeling moments from grain settling and shifting cause a list, assessed under the International Grain Code)
💡 Grain in bulk settles and shifts as the ship rolls, producing heeling moments and a persistent list. The International Grain Code requires stability to be assessed using assumed heeling moments from grain shift, with the resulting angle of heel limited to a prescribed value, normally 12 degrees.
✗
Question 96. How many means of escape are required on each deck in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: A (At least two, widely separated)
💡 At least two widely separated means of escape per deck.
✗
Question 97. Which abnormalities should the steering gear alarm system be capable of indicating on the bridge and in the steering gear compartment?
Your Answer: (Not answered)
Correct Answer: C (Power unit failure, loss of power, overload, low oil level in the tank and failure of the control system power supply)
💡 SOLAS requires the steering gear alarm system to indicate abnormalities such as power unit failure, loss of power, overload, low oil level and failure of the power supply to the control system, so that both the bridge and the engineers learn of a potential steering fault.
✗
Question 98. After a ship has been detained by PSC, when is the detention lifted?
Your Answer: (Not answered)
Correct Answer: B (When the detainable deficiencies have been rectified and verified by re-inspection)
💡 Detention is lifted only when the detainable deficiencies have been rectified and confirmed by re-inspection. An undertaking, security or plan cannot substitute for actual rectification.
✗
Question 99. What preparation of equipment is required before an inspection?
Your Answer: (Not answered)
Correct Answer: D (Confirm critical equipment is serviceable, including testing emergency equipment, and be ready to demonstrate its operation)
💡 Before an inspection, critical equipment such as fire pumps, the emergency fire pump, the emergency generator, the steering gear, lifeboat engines and the fire detection system should be confirmed serviceable and ready to demonstrate, with emergency equipment tested and records kept. Equipment that does not work becomes an immediate deficiency.
✗
Question 100. What determines the type of protection required for electrical equipment in a hazardous area?
Your Answer: (Not answered)
Correct Answer: C (Whether the type of equipment matches the hazard level of the area, such as the zone classification for explosive gas atmospheres)
💡 SOLAS and the IEC standards prescribe the types of protection permitted according to the zone classification of the hazardous area, such as zones 0, 1 and 2. The equipment type must match the area, or it may become a source of ignition.