Question 1. While underway the ship receives word from her Administration that the security level has been raised, while the terminal remains at the former level. What applies on board?
Your Answer: (Not answered)
Correct Answer: A (the notified level being implemented with the master's instructions, co-ordinated with the port facility security officer, the facility's own level not reducing the ship's duty)
💡 Levels are set for the ship by her Administration and for the facility by the Contracting Government; on notice of an increase the ship implements the additional measures of her plan for that level, informs the master, crew and the facility concerned, and settles any mismatch by co-ordination. The terminal staying at the lower level does not reduce the ship's duty, and relaxing the ship to match it is not the answer.
✗
Question 2. What is required when anchoring in restricted visibility?
Your Answer: (Not answered)
Correct Answer: A (Choose a position after confirming suitable depth and bottom and the absence of dangers nearby, keeping radar and visual monitoring afterwards)
💡 If anchoring becomes necessary in poor visibility, the depth and nature of the bottom and the surrounding area should first be confirmed. After anchoring, radar and visual watch should be maintained, dragging monitored, the anchor lights and shapes displayed and engines kept ready.
✗
Question 3. What is the stowage factor used for?
Your Answer: (Not answered)
Correct Answer: C (Estimating the volume the cargo will occupy and judging whether the hold capacity is sufficient)
💡 The stowage factor expresses the volume occupied by unit weight of cargo. It is used to estimate the space required and to judge whether the ship's hold capacity is sufficient for the planned quantity, and is fundamental to stowage calculations.
✗
Question 4. While a pilot is on board, the officer of the watch should:
Your Answer: (Not answered)
Correct Answer: D (Maintain a proper look-out and monitor the pilot's actions)
💡 The OOW remains responsible and must monitor the pilot and keep a proper look-out.
✗
Question 5. A pressure test found insufficient pressure when two jets were played simultaneously. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: A (Fire pumps must maintain the prescribed pressure and jets when the required number of hydrants are in simultaneous use)
💡 SOLAS II-2 requires the fire pumps to maintain the prescribed pressure and reach of the jets with the required number of hydrants in simultaneous use. Insufficient pressure impairs firefighting and is a deficiency.
✗
Question 6. What communication is required when entering an enclosed space?
Your Answer: (Not answered)
Correct Answer: B (Continuous communication with the standby person, including periodic contact, with immediate withdrawal if it is lost)
💡 SOLAS and the IMO resolutions require the entrant to maintain continuous communication with the standby person at the entrance, normally by agreed periodic contact, and to withdraw at once if communication cannot be restored, preventing an incident from going unnoticed.
✗
Question 7. What is the role of the intermediate survey among the surveys of the cargo ship safety equipment certificate?
Your Answer: (Not answered)
Correct Answer: D (It takes the place of one annual survey and examines specified items in greater depth)
💡 The cargo ship safety equipment certificate requires annual and intermediate surveys. The intermediate survey is held on the second or third anniversary date, replacing that annual survey and examining specified items in more depth.
✗
Question 8. What is the purpose of thermal protective aids in a lifeboat in cold waters?
Your Answer: (Not answered)
Correct Answer: A (To wrap persons and reduce loss of body heat, working with immersion suits to prevent hypothermia)
💡 Thermal protective aids in survival craft are used to wrap persons and reduce loss of body heat. Used with immersion suits they significantly extend survival time in cold water, and their number and condition are particularly important when trading in cold climates.
✗
Question 9. What shall embarkation arrangements for survival craft ensure?
Your Answer: (Not answered)
Correct Answer: D (Rapid and orderly boarding and ease of launching)
💡 They shall permit rapid, orderly embarkation and launching.
✗
Question 10. What do SOLAS and good practice address regarding the hydraulic steering gear?
Your Answer: (Not answered)
Correct Answer: A (Oil level and pressure monitoring with alarms, preventing loss of steering through low oil or loss of pressure)
💡 The hydraulic steering gear should have oil level and pressure monitoring with alarms, detecting oil loss or loss of pressure in good time, since steering failure directly endangers the safe manoeuvring of the ship.
✗
Question 11. What does SOLAS address regarding the arrangement of ventilation inlets and outlets in machinery spaces?
Your Answer: (Not answered)
Correct Answer: D (They must be arranged to avoid short circuiting and ensure effective air change)
💡 SOLAS requires the inlets and outlets of machinery space ventilation to be arranged to avoid short circuiting and ensure effective air change, preventing excessive temperature or accumulation of flammable gas, both of which affect equipment and safety.
✗
Question 12. Where shall manual fire alarm call points be located?
Your Answer: (Not answered)
Correct Answer: A (In corridors and near exits where persons can reach them)
💡 They are located in corridors and near exits for easy access.
✗
Question 13. Which radio survival equipment, other than EPIRBs, shall ships of 300 GT and above carry?
Your Answer: (Not answered)
Correct Answer: C (Search and rescue transponder (SART))
💡 The SART assists search and rescue aircraft in locating survivors.
✗
Question 14. What are common reasons for a finding of ISM system failure during a PSC inspection?
Your Answer: (Not answered)
Correct Answer: B (Repeated serious deficiencies of the same kind, records seriously inconsistent with the ship, or the crew unfamiliar with key operations or emergency duties)
💡 Findings of system failure commonly rest on the recurrence of serious deficiencies of the same kind, showing corrective action has been ineffective, records seriously inconsistent with the ship, such as falsified drill records, the crew unfamiliar with the equipment they operate or with their emergency duties, and critical equipment long out of repair, all showing that the system is not being implemented effectively.
✗
Question 15. A cargo ship of 4200 GT on an international voyage. How many independently driven fire pumps are required as a minimum?
Your Answer: (Not answered)
Correct Answer: C (Two)
💡 SOLAS II-2/10.2: cargo ships of 1000 GT and above shall have at least two independently driven fire pumps.
✗
Question 16. What risk does SOLAS address regarding the height of side scuttles in the shell?
Your Answer: (Not answered)
Correct Answer: B (A scuttle set too low may become immersed on list or when shipping seas, allowing water entry)
💡 SOLAS limits the permitted positions of side scuttles and shell openings. A low position may become immersed on list, trim or when shipping seas, allowing water entry; such openings must be considered in subdivision and stability calculations.
✗
Question 17. What does SOLAS address regarding surface materials on bulkheads in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: A (They must restrict flame spread and meet the prescribed requirements for non-combustibility and low flame spread)
💡 SOLAS II-2 prescribes requirements for non-combustibility and low flame spread for the surfaces of bulkheads, ceilings and linings, preventing rapid spread of flame over surfaces. The materials must be approved.
✗
Question 18. A self-igniting light on a lifebuoy is found inoperative because its battery has failed. The finding is?
Your Answer: (Not answered)
Correct Answer: C (The lifebuoy has lost its night-marking capability, a life-saving equipment deficiency to be replaced)
💡 The self-igniting light is used at night to mark the position of a person overboard and is a key attachment of the lifebuoy. A failed battery makes the lifebuoy unidentifiable at night. This is a functional deficiency of life-saving equipment; the battery or light should be replaced so that it is always ready for use.
✗
Question 19. How should oxygen content be tested for enclosed space entry?
Your Answer: (Not answered)
Correct Answer: A (With calibrated instruments at different depths and positions within the space, not merely at the entrance)
💡 Oxygen content and harmful gas concentrations in an enclosed space may vary vertically and from place to place, heavier gases collecting low and lighter ones high. Testing should be carried out at different depths and positions within the space; a reading at the entrance alone does not represent the whole.
✗
Question 20. What is the time requirement for launching and recovering a rescue boat under SOLAS III?
Your Answer: (Not answered)
Correct Answer: B (Recovery must be possible within 5 minutes in moderate sea conditions)
💡 SOLAS III requires a rescue boat to be capable of being launched and recovered within 5 minutes in moderate sea conditions, so that a person in the water can be recovered quickly.
✗
Question 21. What does SOLAS address regarding the subdivision of bilge drainage arrangements?
Your Answer: (Not answered)
Correct Answer: A (The bilge system must be arranged in sections so that water in any compartment can be drained independently)
💡 SOLAS requires the bilge system to be arranged in sections with independent suctions, so that water in any compartment can be drained on its own without affecting others, and the location of flooding can be identified. A single central suction does not meet the requirement.
✗
Question 22. A fixed fire detection system shall raise an alarm:
Your Answer: (Not answered)
Correct Answer: C (when it detects the signs of fire such as smoke or heat at an early stage)
💡 SOLAS II-2/7: a fixed fire detection system shall raise an alarm when it detects the early signs of fire such as smoke or heat.
✗
Question 23. What rowing equipment shall a liferaft carry?
Your Answer: (Not answered)
Correct Answer: D (Oars suitable for rowing)
💡 Oars shall be provided so the raft can be moved short distances.
✗
Question 24. If a vessel cannot give effective assistance to a ship in distress, it shall:
Your Answer: (Not answered)
Correct Answer: C (Record it and report the situation to the appropriate authority)
💡 Record the matter and report to the appropriate authority.
✗
Question 25. What performance must survival craft achieve in respect of wind and sea conditions under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (They must float safely and retain their performance under the prescribed wind and sea conditions)
💡 SOLAS requires survival craft designed for the prescribed wind and sea conditions, able to float safely and maintain their essential performance in heavy weather. A declaration for calm water alone does not meet the needs after abandonment.
✗
Question 26. A VDR shall record:
Your Answer: (Not answered)
Correct Answer: D (date/time, position, speed, heading, bridge audio and other data)
💡 SOLAS V/20: a VDR records date/time, position, speed, heading, radar images and bridge audio.
✗
Question 27. What is the principle for stowing survival craft?
Your Answer: (Not answered)
Correct Answer: A (So that they can be launched quickly and safely under unfavourable conditions)
💡 They shall be stowed so that they can be launched quickly and safely even under unfavourable conditions.
✗
Question 28. What does SOLAS address regarding automatic operation of emergency lighting after loss of the main source?
Your Answer: (Not answered)
Correct Answer: A (Emergency lighting must come on automatically after failure of the main source, without manual action)
💡 SOLAS requires emergency lighting to operate automatically when the main source fails, so that the crew has illuminated guidance at the moment of the blackout. A system requiring manual change-over would be delayed by confusion during the blackout, a common deficiency.
✗
Question 29. Which statement about fatigue management is correct?
Your Answer: (Not answered)
Correct Answer: B (Watches and work should be reasonably arranged to ensure crew have sufficient rest and avoid fatigue-induced errors)
💡 Fatigue is an important human factor in navigational accidents. The ship should reasonably arrange watches and work, ensure the crew obtain sufficient rest as required and monitor rest hour records to avoid judgement and operational errors caused by fatigue. Fatigue management is an important part of the safety management system.
✗
Question 30. In SOLAS I/2 the expression "upright position" is used to define which condition of the ship?
Your Answer: (Not answered)
Correct Answer: B (The reference condition with no heel, used for measuring freeboard and similar particulars)
💡 SOLAS and the Load Line Convention take the upright (no heel) condition as the datum for measuring moulded depth, freeboard and similar particulars, irrespective of the loading condition.
✗
Question 31. Which is the MF digital selective calling distress frequency?
Your Answer: (Not answered)
Correct Answer: A (2187.5 kHz)
💡 2187.5 kHz is the MF DSC distress frequency; 2182 kHz is the MF radiotelephony distress frequency.
✗
Question 32. When a fixed CO2 system serves a machinery space, what key parameter does SOLAS address?
Your Answer: (Not answered)
Correct Answer: C (The quantity released must achieve the prescribed extinguishing concentration and the space must be reasonably gas-tight)
💡 SOLAS requires the CO2 quantity to be calculated from the volume of the space to achieve the prescribed concentration, and the space to be reasonably gas-tight so that leakage does not defeat the system.
✗
Question 33. What are the key points of the monthly inspection of survival craft launching appliances?
Your Answer: (Not answered)
Correct Answer: B (Check the brake, release gear, falls and sheaves and the securing arrangements for operation and condition)
💡 SOLAS III/20 requires a monthly inspection of the launching appliances of survival craft: checking that the brake holds reliably, the release gear operates correctly, the falls and sheaves are free of broken wires and wear and the securing arrangements release properly, with any defects found and the action taken recorded.
✗
Question 34. What is the purpose of a compass corrector on board?
Your Answer: (Not answered)
Correct Answer: C (Eliminating residual deviation of the magnetic compass)
💡 A compass corrector compensates for residual deviation caused by the ship's magnetic field.
✗
Question 35. What is the relationship between the validity of an exemption certificate and the main certificate?
Your Answer: (Not answered)
Correct Answer: B (The exemption certificate must not be valid for longer than the main certificate to which it relates)
💡 SOLAS provides that an exemption certificate must not be valid for a period longer than the main certificate to which it relates. When the main certificate expires or is replaced the exemption certificate must be dealt with accordingly, the two being valid together to give effect to the exemption.
✗
Question 36. What does SOLAS VI/1 require regarding cargo information before loading ordinary cargo?
Your Answer: (Not answered)
Correct Answer: B (The shipper must provide the necessary information about the cargo before loading, so the master can judge its suitability for safe carriage)
💡 SOLAS VI/1 requires the shipper to give the master the necessary information about the cargo before loading, enabling him to judge suitability for safe carriage and the precautions needed. Experience alone or later submission does not comply.
✗
Question 37. What are the key points in lowering a lifeboat during an abandon ship drill?
Your Answer: (Not answered)
Correct Answer: A (Check the brake and release gear, lower under the procedure and take account of the ship's condition)
💡 Lowering a lifeboat in a drill requires checking the brake and release gear, lowering under the procedure with account taken of list and sea conditions and the work done by not fewer than two persons. Rapid release or solo operation is a principal cause of casualties in drills.
✗
Question 38. A 120 m cargo ship has one lifeboat on each side. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (The capacity on each side must accommodate all persons, with at least one boat serving as a rescue boat)
💡 SOLAS requires the capacity on each side of a cargo ship to accommodate all persons on board, with at least one boat meeting the rescue boat requirements. Counting the two boats together would not ensure escape if one side were lost.
✗
Question 39. What does SOLAS require for alarms in automated machinery spaces?
Your Answer: (Not answered)
Correct Answer: C (Alarms on abnormal critical parameters such as temperature, pressure and level, transmitted to the bridge or engineers' accommodation)
💡 SOLAS requires alarms on abnormal critical machinery parameters, transmitted to the bridge or the engineers' accommodation, so that abnormalities are detected during unattended periods and damage or loss of power is avoided.
✗
Question 40. What fire precautions apply at a galley range?
Your Answer: (Not answered)
Correct Answer: D (Combustibles must be kept clear of the range, with a filter and fixed extinguishing system in the hood and effective ventilation)
💡 SOLAS and good practice require combustibles such as cloths and cartons to be kept clear of the galley range, a filter and fixed extinguishing system in the hood and effective ventilation, with flammable liquids not stored near the range, reducing the risk of fire.
✗
Question 41. Which statement about the use of weather routeing is correct?
Your Answer: (Not answered)
Correct Answer: D (The route should be chosen taking account of weather forecasts and the ship's condition, avoiding severe weather and monitoring the passage plan)
💡 Weather routeing should combine professional weather forecasts with the ship's condition, such as stability, cargo and draught, to choose a relatively safe route avoiding typhoons, heavy seas and severe weather, monitoring and adjusting the plan during the voyage. It is an aid, the final navigational decision being the master's responsibility.
✗
Question 42. When must the first drill after leaving port be held?
Your Answer: (Not answered)
Correct Answer: D (Within 24 hours of leaving port, including abandon ship and fire drills)
💡 SOLAS III/19 requires the first drill, including abandon ship and fire drills and, on passenger ships, the participation of passengers, to be held within 24 hours of the ship leaving port, so that newly joined personnel and the whole crew have their emergency duties clear from the start of the voyage.
✗
Question 43. What is required for monitoring stability during loading and unloading?
Your Answer: (Not answered)
Correct Answer: C (Monitor stability and strength at each stage against the loading plan, preventing excessive hogging or sagging or insufficient initial stability)
💡 SOLAS requires stability and hull strength to be monitored at each stage against the loading plan, preventing excessive hogging or sagging and insufficient initial stability. Calculating only afterwards cannot prevent structural damage during cargo work.
✗
Question 44. What is the safety significance of the documentation and declaration system for dangerous goods?
Your Answer: (Not answered)
Correct Answer: A (giving ship, port and administration the nature, quantity and hazards of the goods so stowage, segregation and the emergency side can be prepared)
💡 Nobody opens every package on board; what the goods are, how they are packed, how much there is, and what the emergency and first-aid measures are all come from the shipper's document and the container packing certificate. Stowage and segregation are laid out from that paper, keeping incompatible goods apart and the means of detection and access free, and the emergency response is planned from the same sheet. When something goes wrong the fire party and the salvage decision work from the declaration, and a false one buys the wrong extinguishing agent and the wrong segregation, which is what turns one incident into two. The paper therefore has to be correct before loading, not made up afterwards; it settles liability too, but its first use is safety.
✗
Question 45. The recording device of an inert gas system may record:
Your Answer: (Not answered)
Correct Answer: B (oxygen content, gas pressure and time)
💡 SOLAS II-2/5 requires continuous recording of oxygen content, gas pressure and time.
✗
Question 46. What mainly determines the minimum range of a radar installation?
Your Answer: (Not answered)
Correct Answer: C (Pulse width and antenna height)
💡 Minimum range depends chiefly on pulse width and the height of the antenna.
✗
Question 47. What does COLREG require regarding sound signals in areas of dense traffic?
Your Answer: (Not answered)
Correct Answer: A (Manoeuvring and warning signals must be given as prescribed, with light signals where appropriate)
💡 COLREG requires vessels in sight of one another to give the prescribed manoeuvring signals, such as one short blast for a starboard alteration, and to sound warning signals in narrow channels or at a bend. Sound signals are an important means of indicating intention and warning others.
✗
Question 48. Which symbol denotes the degree of subdivision of a passenger ship?
Your Answer: (Not answered)
Correct Answer: D (R)
💡 A required subdivision index is applied to passenger ships.
✗
Question 49. What are the marking and labelling requirements for packaged dangerous goods?
Your Answer: (Not answered)
Correct Answer: B (The correct proper shipping name, UN number and class labels should be shown under the IMDG Code, clearly and durably)
💡 Under SOLAS VII and the International Maritime Dangerous Goods Code packaged dangerous goods should be correctly marked with the proper shipping name and UN number and labelled with the appropriate class and subsidiary risk labels, clearly, durably and conspicuously. Incorrect marking affects stowage, segregation and emergency response.
✗
Question 50. Within an emission control area, what is the sulphur limit of fuel oil used on board?
Your Answer: (Not answered)
Correct Answer: A (0.10 per cent m/m)
💡 Within an emission control area the sulphur limit of fuel oil used on board is 0.10 per cent m/m. The ship should be able to show compliance through bunker delivery notes, changeover procedures and records, and should allow sufficient changeover time before entering the area.
✗
Question 51. What does SOLAS address regarding zoning of fire detection systems?
Your Answer: (Not answered)
Correct Answer: C (The system must identify the section in which the alarm originated, enabling the fire to be located quickly)
💡 SOLAS requires fixed fire detection systems to be arranged in sections so that the alarm indicates the section or space in which it originated, enabling the watchkeeper to confirm the actual location and act quickly.
✗
Question 52. How is a flag State expected to exercise control over ships flying its flag under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Through statutory surveys, certification and, where necessary, additional inspections)
💡 SOLAS XI-1/4 requires the flag State to exercise control through the statutory survey and certification system, with additional inspections where necessary. Reliance on PSC results alone is insufficient.
✗
Question 53. What is required to restore survival craft after use?
Your Answer: (Not answered)
Correct Answer: A (Clean promptly after use or a drill, replenish consumables, re-secure and return to stowage, restoring immediate readiness)
💡 SOLAS requires survival craft to be cleaned promptly after a drill or use, the equipment and supplies consumed such as water and pyrotechnics replenished and the craft re-secured and returned to stowage, restoring immediate readiness. Long neglect would make the appliance unusable in an emergency.
✗
Question 54. What should be done if the loading instrument of a bulk carrier computes abnormally?
Your Answer: (Not answered)
Correct Answer: D (Stop relying on it and use an approved manual method or shore support, repairing and verifying it as soon as possible)
💡 If a loading instrument computes abnormally, such as results clearly differing from hand calculation or the program reporting errors, reliance on it should cease and an approved manual method or shore support used to complete the strength and stability checks, with the instrument repaired and verified as soon as possible, preventing a wrong result from causing overloading or structural damage.
✗
Question 55. What does SOLAS address regarding gravity davits?
Your Answer: (Not answered)
Correct Answer: B (The craft must be launched by gravity without power and capable of being released from within the craft)
💡 SOLAS requires a gravity davit to launch the craft by gravity without power and to be capable of release from within the craft, so that abandonment can still be carried out if power is lost or personnel are dispersed.
✗
Question 56. An emergency steering drill was held and direct steering from the steering gear compartment was required. What do SOLAS and STCW require?
Your Answer: (Not answered)
Correct Answer: A (An emergency steering drill at least every three months, including direct steering from the steering gear compartment and the communication procedure)
💡 SOLAS and STCW require emergency steering drills at least every three months, practising direct steering from the steering gear compartment and the communication procedure with the bridge, so that the crew can respond if steering control fails. A briefing is not a substitute.
✗
Question 57. What is one of the main functions of an Inmarsat-C ship earth station in GMDSS?
Your Answer: (Not answered)
Correct Answer: B (Transmitting and receiving distress alerts and enhanced group call maritime safety information)
💡 Inmarsat-C can transmit distress alerts, receive EGC SafetyNET information and provide two-way messaging, making it an important means of meeting GMDSS requirements in sea area A3.
✗
Question 58. To which tankers does the emergency towing arrangement requirement of SOLAS II-1/3-3 apply?
Your Answer: (Not answered)
Correct Answer: D (Oil tankers of 20000 tonnes deadweight and above)
💡 SOLAS II-1/3-3 requires oil tankers of 20000 tonnes deadweight and above to be fitted with an emergency towing arrangement at bow and stern, so that a disabled tanker can be taken in tow. It is not limited to new ships.
✗
Question 59. What measures prevent persons falling overboard?
Your Answer: (Not answered)
Correct Answer: C (Guard rails and lifelines, non-slip and well drained decks, good lighting and avoiding unnecessary deck work in heavy weather)
💡 Preventing a person from going overboard requires measures in combination: guard rails and lifelines at the sides, decks kept non-slip and well drained, lighting improved at night and in heavy weather, unnecessary deck work avoided and lifejackets and harnesses worn as required, reducing the risk.
✗
Question 60. What layers of protection do SOLAS and the IMO resolutions require for enclosed space entry?
Your Answer: (Not answered)
Correct Answer: B (Ventilation, testing, a permit, a standby person and rescue preparation forming a complete entry procedure)
💡 SOLAS and the IMO resolutions require a complete procedure for enclosed space entry: ventilation, testing, a permit, a standby person and rescue arrangements. The layers work together; no single measure ensures safety.
✗
Question 61. What is the purpose of self-closing doors on escape routes?
Your Answer: (Not answered)
Correct Answer: B (To block the spread of smoke and flame)
💡 They block smoke and flame from spreading.
✗
Question 62. On what basis should a maintenance programme be prepared?
Your Answer: (Not answered)
Correct Answer: C (The manufacturer's instructions, classification society requirements and the ship's actual service experience, revised as necessary)
💡 The ISM Code requires the maintenance programme to be based on the manufacturer's instructions and the requirements of the classification society and regulations, together with the actual service history of the equipment, failure history and survey findings, and to be revised after modification or failure, so that it remains effective.
✗
Question 63. What is required when an electronic aid such as GPS behaves abnormally?
Your Answer: (Not answered)
Correct Answer: B (Recognise the abnormality and switch promptly to other means of position fixing, recording and reporting the situation)
💡 Abnormal behaviour of GPS, such as a jump in position, loss of signal or an integrity alarm, should be recognised with prompt recourse to radar, visual fixing and other means for cross-checking, and the matter recorded and reported. In confined waters this avoids grounding from an error in a single aid.
✗
Question 64. Where the main steering gear comprises two or more identical power units, what does SOLAS require if one fails?
Your Answer: (Not answered)
Correct Answer: C (The remaining units must continue to steer the ship and change-over must be effected quickly)
💡 SOLAS requires that, with multiple power units, the remaining unit or units continue to steer the ship and that change-over is effected within the prescribed time, so control is never lost.
✗
Question 65. In which circumstances must the officer of the watch notify the master immediately?
Your Answer: (Not answered)
Correct Answer: B (In restricted visibility, on failure of machinery or steering gear, or on encountering a hazard to safety)
💡 STCW and SOLAS require the officer of the watch to call the master immediately in restricted visibility, on failure of machinery or steering gear, or on encountering anything that may endanger safety, or when in doubt.
✗
Question 66. What does SOLAS address regarding separation between the cargo area and machinery space of a tanker?
Your Answer: (Not answered)
Correct Answer: B (A-60 class separation between the cargo tank area and category A machinery spaces, preventing passage of vapour and fire)
💡 SOLAS requires A-60 class separation between the cargo tank area and category A machinery spaces of a tanker, preventing vapour from entering the machinery space or fire spreading from it into the cargo area with far greater consequences.
✗
Question 67. What does SOLAS require for the display of the rudder angle indicator on the bridge?
Your Answer: (Not answered)
Correct Answer: D (It must display the actual rudder angle, and on larger ships also at the emergency steering position)
💡 SOLAS requires a rudder angle indicator on the bridge showing the actual rudder angle, so the helmsman can confirm the true position of the rudder. Showing the order only or an inaccurate indication leads to steering errors.
✗
Question 68. What is the primary purpose of ships' routeing under SOLAS V/10?
Your Answer: (Not answered)
Correct Answer: B (To improve safety of navigation and reduce the risk of collision and grounding)
💡 SOLAS V/10 states that the purpose of ships' routeing is to improve safety of navigation and reduce the risk of collision, not to delimit jurisdiction or increase speed.
✗
Question 69. A crew member's actual rank does not match the certificate held, a junior certificate being used for a senior post. The finding is?
Your Answer: (Not answered)
Correct Answer: A (Serving with a mismatched certificate is an illegal manning arrangement, a serious deficiency to be corrected)
💡 A crew member's certificate of competency should match the rank held. Using a lower-grade certificate for a higher post is an illegal manning arrangement. It weakens the capability of the post and violates the safe manning requirements. It is a serious deficiency to be corrected, normally by changing personnel or supplying properly certificated crew.
✗
Question 70. What is the basic requirement for cargo carriage under SOLAS VI?
Your Answer: (Not answered)
Correct Answer: D (Cargo shall be loaded, stowed and secured with regard for stability and structural strength)
💡 Loading, stowage and securing shall not endanger the ship's safety or stability.
✗
Question 71. Among the personal life-saving appliances to be provided to each crew member, which is mandatory?
Your Answer: (Not answered)
Correct Answer: D (A lifejacket, with additional ones for watchkeeping positions and remote locations)
💡 Under SOLAS III/7 and III/32 a lifejacket should be provided to each crew member and every person on board, with additional ones to meet watchkeeping positions and remote locations. The lifejacket is personal life-saving equipment and the most basic protection during abandonment.
✗
Question 72. What does SOLAS address regarding the location of the emergency fire pump?
Your Answer: (Not answered)
Correct Answer: A (Located outside the machinery space with independent power and a separate suction)
💡 SOLAS requires the emergency fire pump to be located outside category A machinery spaces with an independent source of power and a separate suction, so that it is not affected by a fire in that space and can draw water independently.
✗
Question 73. Segregation is required when dangerous goods are stowed on board. What is the fundamental purpose?
Your Answer: (Not answered)
Correct Answer: B (To prevent incompatible substances reacting dangerously on contact)
💡 Segregation under SOLAS VII/3 and the IMDG Code prevents incompatible substances from reacting if released, causing fire, explosion or toxic gas. It is not a tallying convenience.
✗
Question 74. What is required of records of spare parts and stores?
Your Answer: (Not answered)
Correct Answer: A (Record the stock, issue and replenishment of spares and safety stores, ensuring critical items are available)
💡 The stock, issue and replenishment of spare parts and safety stores such as extinguisher charges, distress signals and protective equipment should be recorded, with the minimum stock levels checked periodically, ensuring critical spares and safety stores are available when needed.
✗
Question 75. What action do SOLAS and STCW require if the main engine fails while under way?
Your Answer: (Not answered)
Correct Answer: A (Notify the bridge immediately, display the appropriate lights, shapes or sound signals and take action such as anchoring or other avoidance measures)
💡 Engine failure deprives the ship of manoeuvrability. The bridge must be informed at once, the lights, shapes or signals for a vessel not under command displayed, and measures such as anchoring taken to avoid collision, with the authorities informed.
✗
Question 76. Which of the following would invalidate a cargo ship safety construction certificate?
Your Answer: (Not answered)
Correct Answer: B (Major alterations to hull or machinery without approval of the Administration)
💡 SOLAS I/15 provides that certificates cease to be valid if major alterations are made to hull, machinery or equipment without the sanction of the Administration. Change of name, crew or manager does not affect validity.
✗
Question 77. What operational requirement relates to ballast water and SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Ballasting according to stability and strength requirements, preventing excessive hogging or sagging and insufficient stability)
💡 Ballast operations must follow stability and strength requirements so the ship keeps an appropriate draught, trim and stability. Excessive ballast or a poor sequence overstresses the hull, so the loading plan must be followed.
✗
Question 78. What should be done with the receiving equipment after a weather warning is received?
Your Answer: (Not answered)
Correct Answer: A (Confirm the message was received complete, retain or print it as required and report important warnings to the bridge promptly)
💡 Weather and navigational warnings received by NAVTEX or EGC should be confirmed as received in full, avoiding loss of information from character errors or interrupted reception, retained or printed as required, with important warnings such as gale or ice warnings reported promptly to the bridge for the conduct of the voyage.
✗
Question 79. Extension of a certificate is permitted:
Your Answer: (Not answered)
Correct Answer: B (only in special circumstances when the ship is not in a port of survey, as authorized by the Administration)
💡 SOLAS I/14: extension of a certificate is permitted only in special circumstances when the ship is not in a port of survey.
✗
Question 80. Galleys within accommodation spaces shall generally be bounded by:
Your Answer: (Not answered)
Correct Answer: D (A class or B class divisions)
💡 SOLAS II-2/9 requires galleys and other high-fire-risk spaces to be bounded by A or B class divisions.
✗
Question 81. What is required for updating the fire control plan?
Your Answer: (Not answered)
Correct Answer: B (Updated promptly when the arrangement or fire protection changes, keeping it consistent with the ship)
💡 SOLAS requires the fire control plan to be updated promptly when the arrangement, fire divisions or extinguishing equipment change, keeping it consistent with the ship. A plan not matching the ship would lead shore firefighters to a wrong appreciation on boarding.
✗
Question 82. What does SOLAS address regarding the effect on stability of loading high density cargo?
Your Answer: (Not answered)
Correct Answer: C (A low centre of gravity increases the initial metacentric height but may cause violent rolling and increased structural stress)
💡 High density cargo stowed low produces an excessive initial metacentric height and a stiff ship with a short rolling period and violent rolling, which may shift cargo and increase structural stresses. Stability should therefore be kept within a reasonable range.
✗
Question 83. What determines the type of protection required for electrical equipment in a hazardous area?
Your Answer: (Not answered)
Correct Answer: C (Whether the type of equipment matches the hazard level of the area, such as the zone classification for explosive gas atmospheres)
💡 SOLAS and the IEC standards prescribe the types of protection permitted according to the zone classification of the hazardous area, such as zones 0, 1 and 2. The equipment type must match the area, or it may become a source of ignition.
✗
Question 84. What is the usual maximum validity of a Passenger Ship Safety Certificate?
Your Answer: (Not answered)
Correct Answer: D (Twelve months)
💡 Under SOLAS I/12 a Passenger Ship Safety Certificate has a usual validity of not more than twelve months, unlike the certificates of a cargo ship, with the relevant surveys completed within the period. Because a passenger ship carries many people, its surveys and certificate management are more frequent.
✗
Question 85. Radio equipment shall be checked for proper performance:
Your Answer: (Not answered)
Correct Answer: B (daily)
💡 SOLAS IV/10 requires daily checks of radio equipment performance.
✗
Question 86. Which systems may be used as fixed fire-extinguishing systems in machinery spaces?
Your Answer: (Not answered)
Correct Answer: C (approved gas, pressure water-spraying or foam systems)
💡 SOLAS II-2/10: approved fixed gas, pressure water-spraying or foam systems may be used in machinery spaces.
✗
Question 87. What does the Polar Code address regarding ice class of ships in polar waters?
Your Answer: (Not answered)
Correct Answer: A (A ship must have an ice class appropriate to the ice conditions, with action taken if conditions exceed her capability)
💡 The Polar Code requires a ship to have an ice class appropriate to the ice conditions of the intended area, categorised as A, B or C, and to take action such as altering course or stopping if conditions exceed her capability. Blindly entering ice beyond her ability is not acceptable.
✗
Question 88. Charts shall be corrected:
Your Answer: (Not answered)
Correct Answer: B (in accordance with the latest notices to mariners)
💡 SOLAS V/27 requires charts and publications to be corrected up to date from notices to mariners.
✗
Question 89. What is the safety significance of spare parts management?
Your Answer: (Not answered)
Correct Answer: D (Essential parts must be carried for critical equipment so that failures can be repaired promptly without affecting safety)
💡 Carrying spares for critical safety equipment, such as parts for fire pumps, wearing components of the emergency generator and steering gear and items of life-saving equipment, enables failures to be repaired promptly, avoiding the ship remaining in a deficient state for a long time while spares are awaited, which would affect her safety.
✗
Question 90. What is examined in testing a fixed fire detection and alarm system?
Your Answer: (Not answered)
Correct Answer: B (The alarm function of detectors tested point by point or by section, and that the display corresponds to the actual location)
💡 Testing a fixed detection and alarm system involves triggering detectors point by point or by section and confirming that the alarm sounds correctly and accurately indicates the space concerned, so that the watchkeeper can locate it quickly. Powering it on or listening for the sound alone does not confirm correct sectional indication.
✗
Question 91. What does SOLAS and the related requirements say about adjusting the magnetic compass?
Your Answer: (Not answered)
Correct Answer: D (It must be properly adjusted, with deviation table and adjustment records kept)
💡 SOLAS requires the magnetic compass to be adjusted with a deviation table and records of adjustment kept,so that the crew can convert compass readings to true headings. An unadjusted compass introduces errors in position fixing and steering.
✗
Question 92. What is the period of validity of the International Ship Security Certificate?
Your Answer: (Not answered)
Correct Answer: C (Not more than five years)
💡 SOLAS XI-2 provides that the ISSC is valid for not more than five years, with intermediate verification arranged separately. It is not valid indefinitely.
✗
Question 93. Which spaces must emergency lighting cover at a minimum under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (Embarkation stations, survival craft stowage positions, escape routes, machinery spaces and the bridge, among other essential spaces)
💡 SOLAS requires emergency lighting for essential spaces including embarkation stations, survival craft stowage positions, escape routes, machinery spaces, the bridge and fire control stations, supporting abandonment and emergency operations.
✗
Question 94. What fire precautions apply before entering a cargo tank or other enclosed space on a tanker?
Your Answer: (Not answered)
Correct Answer: C (Thorough ventilation and gas testing to confirm no flammable gas and acceptable oxygen content, with ventilation maintained during entry)
💡 Before entering a cargo tank, pump room or similar enclosed space on a tanker, thorough ventilation is required with testing of flammable gas, toxic gas and oxygen content all satisfactory, and an entry permit obtained, ventilation maintained during the entry and explosion-protected lighting and tools used, preventing ignition.
✗
Question 95. What is the purpose of thermal protective aids among the lifeboat equipment?
Your Answer: (Not answered)
Correct Answer: C (Providing thermal protection for persons in the boat and reducing loss of body heat)
💡 Thermal protective aids in a lifeboat are used to keep persons warm and reduce loss of body heat, preventing hypothermia in cold conditions. They do not provide buoyancy.
✗
Question 96. What does SOLAS address regarding sounding pipes?
Your Answer: (Not answered)
Correct Answer: A (They must reach the bottom of the tank with reliable closing appliances, positioned for easy sounding without impairing watertightness)
💡 SOLAS requires sounding pipes to reach the bottom of the tank for accurate measurement, with reliable closing appliances, positioned for convenient sounding without impairing watertightness or safety. Pipes passing through accommodation spaces require particular care to prevent escape of vapour.
✗
Question 97. What is the significance of the marine pollutant mark required by the IMDG Code?
Your Answer: (Not answered)
Correct Answer: A (It identifies a cargo harmful to the environment, requiring stricter pollution prevention measures if it leaks)
💡 The IMDG Code requires the marine pollutant mark on goods meeting the criteria, identifying a cargo that would harm the environment if released. Stricter pollution prevention and response requirements apply to a spill, with reporting as prescribed.
✗
Question 98. After failure of the main steering gear, within what time must the auxiliary steering gear be brought into use?
Your Answer: (Not answered)
Correct Answer: D (7 seconds for a passenger ship and 45 seconds for a cargo ship, the changeover being proved in drills)
💡 The time is fixed by type of ship: on a passenger ship the auxiliary gear must be capable of being brought into use within 7 seconds after failure of the main gear, and within 45 seconds on a cargo ship; the arrangements must also be such that failure of one does not render the other inoperative, and the changeover is worked and logged at drills. Blurring the figures into one minute, or treating multiple power units as replacing the auxiliary gear, is found out in the exercise or in a real failure.
✗
Question 99. Survival craft shall be capable of rapid launching:
Your Answer: (Not answered)
Correct Answer: B (under unfavourable conditions of trim and list)
💡 SOLAS III/16 requires rapid launching under unfavourable conditions of trim and list.
✗
Question 100. What is required for route monitoring when using electronic charts?
Your Answer: (Not answered)
Correct Answer: B (Continuously monitor the deviation from the planned route, act on and acknowledge safety alarms and correct as necessary)
💡 When ECDIS is in use the deviation from the planned route should be monitored continuously and safety alarms such as off-track and approaching danger acted on and acknowledged, with course corrections as necessary. Setting the route and then neglecting to monitor it is not acceptable.