Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. What priority applies to distress communication under SOLAS and the Radio Regulations?
Your Answer: (Not answered)
Correct Answer: D (Distress takes priority over urgency, and urgency over safety)
💡 SOLAS and the Radio Regulations set the order of priority as distress, urgency, safety and other communication. Distress traffic has absolute priority; other traffic must give way and must not occupy distress frequencies for unrelated communication.
✗
Question 2. What determines the number of fireman's outfits to be carried?
Your Answer: (Not answered)
Correct Answer: A (The gross tonnage)
💡 The number of fireman's outfits is determined by the gross tonnage.
✗
Question 3. How should fire hoses be used in a fire drill?
Your Answer: (Not answered)
Correct Answer: C (Use hydrants and hoses at designated positions under the drill plan to verify the system, avoiding waste and damage to equipment)
💡 In a fire drill, hydrants and hoses should be used at designated safe positions to verify hose connection, nozzle handling and supply pressure, giving the crew practical experience. After using substantial water, drainage and anti-slip measures should be taken and cargo and equipment protected.
✗
Question 4. How should safety meetings be organised?
Your Answer: (Not answered)
Correct Answer: B (Held periodically, such as monthly, to discuss safety matters, lessons from incidents and improvements, with records kept)
💡 The ISM Code and good practice require safety meetings to be held periodically on board, normally monthly or each voyage, to discuss recent safety matters, lessons from accidents and near misses, hazard identification and improvement measures, with records kept including participants and what was discussed, raising the crew's awareness and involvement.
✗
Question 5. How should the hands-on ability of the crew be assessed?
Your Answer: (Not answered)
Correct Answer: D (Assessed through practical drills on critical equipment, with training strengthened where it is weak)
💡 The ISM Code and STCW require the practical ability of the crew on critical equipment to be assessed through drills, such as donning breathing apparatus, using extinguishers and hoses, preparing to launch a lifeboat, emergency steering and damage control operations, with training strengthened where skill is lacking, so that the ability is genuinely usable.
✗
Question 6. What time limits apply to launching and recovering a rescue boat?
Your Answer: (Not answered)
Correct Answer: B (Launching and recovery, when loaded, each within 5 minutes)
💡 Launching and recovery when fully loaded shall each be within 5 minutes.
✗
Question 7. In which circumstances must the ship security assessment be updated?
Your Answer: (Not answered)
Correct Answer: C (On major changes to the ship's structure, manning or operations, or on a change in the security situation)
💡 ISPS Code Part A/6 requires the ship security assessment to be reviewed and updated on major changes to the ship's structure, personnel or operations, or on a security incident or change of security level, keeping it consistent with the actual situation.
✗
Question 8. What is the particular danger of a cargo leak on a gas carrier?
Your Answer: (Not answered)
Correct Answer: A (The cargo is often cryogenic, flammable or toxic; a leak vaporises rapidly and may form a flammable or toxic cloud)
💡 Gas carrier cargoes such as LPG and LNG are cryogenic, flammable, explosive or toxic. A leak vaporises rapidly and mixes with air to form a flammable or toxic cloud which may flash or explode on contact with a source of ignition, so the response must be by trained personnel.
✗
Question 9. What should the ventilation measures meet before entering an enclosed space?
Your Answer: (Not answered)
Correct Answer: A (Adequate ventilation should be provided and the atmosphere tested as satisfactory before entry, with continuous ventilation and an attendant during the work)
💡 Before entering an enclosed space adequate ventilation should be provided and the atmosphere tested for oxygen, flammable gas and toxic gas and confirmed satisfactory, and during entry ventilation should be continuous, an attendant stationed at the entrance and communication maintained. Entry without ventilation, testing or an attendant is prohibited.
✗
Question 10. What does SOLAS and the Polar Code require regarding manning and training for polar waters?
Your Answer: (Not answered)
Correct Answer: A (The master and officers in charge of a navigational watch must have completed appropriate polar waters training and gained the required experience)
💡 SOLAS XIV and STCW require the master and officers in charge of a navigational watch of a ship in polar waters to have completed polar waters training appropriate to the ship's category and to have the prescribed seagoing experience, ensuring the ability to operate in polar conditions.
✗
Question 11. One space uses smoke detectors and another heat detectors. What is the main basis for choosing detector type?
Your Answer: (Not answered)
Correct Answer: A (The type and characteristics of fire likely in the space, such as smoke production or rapid temperature rise)
💡 SOLAS requires the detector type to suit the fire expected in the space: smoke detectors where smoke will be produced, heat detectors where rapid temperature rise without much smoke may occur. The wrong choice delays the alarm.
✗
Question 12. What is the purpose of an inert gas system?
Your Answer: (Not answered)
Correct Answer: D (Reducing oxygen content in cargo tanks to prevent explosion)
💡 It reduces the oxygen content so that flammable vapour cannot ignite.
✗
Question 13. What is the purpose of the transmitting heading device on board?
Your Answer: (Not answered)
Correct Answer: D (To distribute the heading signal from the gyro compass to radar, AIS and similar equipment)
💡 The transmitting heading device supplies the heading to radar, AIS, ECDIS and other equipment, ensuring consistent heading data and avoiding errors in control and display.
✗
Question 14. What does SOLAS address regarding fire protection on the cargo tank deck of a tanker?
Your Answer: (Not answered)
Correct Answer: B (Measures to prevent sparks and high temperature and to keep firefighting equipment available)
💡 SOLAS requires the deck and openings of a tanker's cargo area to be arranged to prevent sparks, high temperature and impact from creating a source of ignition, with deck foam systems, hydrants and other equipment kept ready for use.
✗
Question 15. What is the validity of the DOC?
Your Answer: (Not answered)
Correct Answer: C (5 years)
💡 Not more than 5 years, subject to annual verification.
✗
Question 16. The lifeboat drill records for three consecutive months are identical. What is the PSCO's concern?
Your Answer: (Not answered)
Correct Answer: B (It may indicate that drills were not actually carried out with different scenarios or that the records are not truthful, requiring verification of their genuineness)
💡 Identical drill records over successive months raise doubt about the genuineness and effectiveness of the drills, and the PSCO may check the crew's practical ability further. Scenarios should vary and address different risks, and the records should reflect what was actually done.
✗
Question 17. What is the relationship between the validity of an exemption certificate and the main certificate?
Your Answer: (Not answered)
Correct Answer: B (The exemption certificate must not be valid for longer than the main certificate to which it relates)
💡 SOLAS provides that an exemption certificate must not be valid for a period longer than the main certificate to which it relates. When the main certificate expires or is replaced the exemption certificate must be dealt with accordingly, the two being valid together to give effect to the exemption.
✗
Question 18. What do SOLAS and good practice address regarding monitoring of cargo during a voyage?
Your Answer: (Not answered)
Correct Answer: B (Check cargo securing, temperature and humidity and ventilation as planned, detecting and dealing with abnormalities in good time)
💡 During the voyage, the security of the cargo lashings, the temperature and humidity and the ventilation of the holds and any smell or sign of heating should be checked as planned, with action taken on self-heating, shifting or chemical reaction. A check before sailing alone does not cover the voyage.
✗
Question 19. How shall watertight doors be operable locally?
Your Answer: (Not answered)
Correct Answer: B (By two persons, one from each side)
💡 They shall be operable locally by two persons, one from each side.
✗
Question 20. What is the usual SOLAS requirement for the number of portable extinguishers in a machinery space?
Your Answer: (Not answered)
Correct Answer: D (A prescribed number according to the volume and arrangement of the space, with at least a stated number in each space)
💡 SOLAS II-2/10.3 requires a prescribed number of portable extinguishers in machinery spaces according to volume and arrangement, with at least a stated number in each space. An inadequate number is a common deficiency.
✗
Question 21. What does SOLAS address regarding lighting and marking of survival craft stowage?
Your Answer: (Not answered)
Correct Answer: D (Lighting and markings at the stowage positions and embarkation stations, enabling identification and operation at night)
💡 SOLAS requires the stowage positions of survival craft and the embarkation stations to be provided with lighting and clear markings such as signs or reflective tape, enabling persons to find the boarding positions and appliances quickly at night or in dense smoke.
✗
Question 22. What emergency supplies must be carried?
Your Answer: (Not answered)
Correct Answer: D (Portable emergency lighting, life-saving equipment, first aid supplies, emergency water and food and communication equipment, checked periodically)
💡 A ship should carry and check periodically the emergency supplies: portable emergency lighting, life-saving equipment, first aid medicines and equipment, emergency water and food, portable communication equipment including two-way VHF and damage control and firefighting equipment, ensuring they are available immediately in an emergency.
✗
Question 23. What is required in setting the safety contour on ECDIS?
Your Answer: (Not answered)
Correct Answer: D (Set it in accordance with the ship's draught and the required under-keel clearance so that it reflects the actual safe depth)
💡 The safety contour and safety depth on ECDIS should be set according to the ship's draught, her under-keel clearance policy and the depths of the area, so that the system alarms accurately when approaching shoal water. An unsuitable default setting may make the alarm ineffective or cause constant false alarms.
✗
Question 24. What are the restrictions on non-protected portable equipment in tanker cargo tanks?
Your Answer: (Not answered)
Correct Answer: D (Equipment such as ordinary torches or non-protected radios may not be used where vapour may accumulate)
💡 Vapour may accumulate in the cargo tanks, pump room and adjacent spaces of a tanker, so equipment that may produce a spark, such as ordinary torches, non-protected radios, power tools and camera flashes, is prohibited. Intrinsically safe or explosion-protected equipment must be used.
✗
Question 25. An 80 m cargo ship is under plan approval. What does SOLAS II-1/10 require regarding the double bottom?
Your Answer: (Not answered)
Correct Answer: A (For ships of 76 m and above a double bottom shall be fitted as far as practicable between the collision and afterpeak bulkheads)
💡 SOLAS II-1/10 requires a double bottom, as far as practicable, between the collision bulkhead and the afterpeak bulkhead for cargo ships of 76 m and above. It does not require it throughout the whole ship.
✗
Question 26. The 15ppm oil content meter alarm is inoperative and the automatic discharge stopping function does not operate. The finding is?
Your Answer: (Not answered)
Correct Answer: C (Loss of monitoring and automatic stop means an over-limit discharge cannot be prevented; a serious deficiency)
💡 The 15ppm oil content meter and the automatic discharge stopping device are key equipment for controlling the discharge of bilge water. The failure of the alarm and of the automatic stop means that an over-limit discharge cannot be automatically prevented and an illegal discharge may result. It is a serious deficiency affecting pollution prevention.
✗
Question 27. How should hazard identification and risk assessment be carried out on board?
Your Answer: (Not answered)
Correct Answer: B (Identify hazards and assess risks for shipboard operations and equipment and take control measures accordingly)
💡 The ISM Code requires hazard identification and risk assessment on board for operations and equipment, covering routine and non-routine work and new equipment and new operations, from which control measures are decided and incorporated into procedures and checklists, bringing risks under control in advance.
✗
Question 28. What must the PWOM contain regarding operational measures for polar waters?
Your Answer: (Not answered)
Correct Answer: A (Ice assessment in voyage planning, ship capability limitations, emergency procedures and training requirements)
💡 The Polar Water Operational Manual must cover voyage planning, ice assessment, the ship's ice class capabilities and limitations, operation of equipment in low temperature, emergency procedures and training, guiding the master's decisions in ice.
✗
Question 29. The emergency generator's automatic starting device is found inoperative and manual starting is required. The finding is?
Your Answer: (Not answered)
Correct Answer: B (The emergency source cannot come on automatically as required, a deficiency affecting emergency power supply)
💡 The emergency generator should start automatically when the main power fails and take up the emergency load within the specified time. A failed automatic starting device means power may not be restored in time after a blackout, directly affecting emergency lighting, steering gear and communications. It is a deficiency to be corrected.
✗
Question 30. Which fixed fire-extinguishing system shall be provided for the cargo tank deck area of a tanker?
Your Answer: (Not answered)
Correct Answer: A (Deck foam system)
💡 SOLAS II-2/10.5: tankers shall be fitted with a fixed deck foam system for the cargo tank deck area.
✗
Question 31. Extension of a certificate is permitted:
Your Answer: (Not answered)
Correct Answer: B (only in special circumstances when the ship is not in a port of survey, as authorized by the Administration)
💡 SOLAS I/14: extension of a certificate is permitted only in special circumstances when the ship is not in a port of survey.
✗
Question 32. What factors must a voyage plan consider under SOLAS and good practice?
Your Answer: (Not answered)
Correct Answer: A (Prohibited and restricted areas, shoal water and draught limits, traffic density, weather and tides, and emergency shelter)
💡 A voyage plan should consider prohibited and exercise areas, shoal water and draught limitations, traffic density, weather and tidal conditions and emergency shelter anchorages and alternative routes, making the passage safe and practicable with contingency arrangements.
✗
Question 33. Which statement about the role of the NAVTEX receiver in sea areas A1 and A2 is correct?
Your Answer: (Not answered)
Correct Answer: D (It automatically receives and prints maritime safety information broadcast by coast stations in the area)
💡 NAVTEX is a receive-only device that automatically prints MSI such as navigational warnings and weather forecasts broadcast by coast stations on 518 kHz. It neither transmits alerts nor carries two-way traffic.
✗
Question 34. What is the function of a thermal protective aid?
Your Answer: (Not answered)
Correct Answer: D (To reduce loss of body heat in a survival craft and prevent hypothermia)
💡 A thermal protective aid is used to wrap a person and reduce loss of body heat in a survival craft, preventing hypothermia. It has no buoyancy and is not used to immobilise casualties.
✗
Question 35. What do SOLAS and good practice require of the electrical system after a fire?
Your Answer: (Not answered)
Correct Answer: A (Assess the circuits and equipment affected, isolate the faulty part and prioritise supply to emergency and firefighting equipment)
💡 After a fire the circuits affected should be assessed, the faulty part isolated and priority given to supplying emergency lighting, fire pumps and communications, preventing secondary incidents from short circuits or water. Cutting all power would defeat firefighting and evacuation.
✗
Question 36. What is the principle for stowing survival craft?
Your Answer: (Not answered)
Correct Answer: A (So that they can be launched quickly and safely under unfavourable conditions)
💡 They shall be stowed so that they can be launched quickly and safely even under unfavourable conditions.
✗
Question 37. What does COLREG require for crossing a traffic lane in a routeing scheme?
Your Answer: (Not answered)
Correct Answer: C (Cross as nearly as practicable at right angles to the lane and avoid impeding vessels following the lane)
💡 COLREG Rule 10 requires a vessel crossing a traffic lane to do so as nearly as practicable at right angles to the general direction of traffic flow and to avoid impeding vessels following the lane. Diagonal or contrary navigation disrupts the flow and increases the risk of collision.
✗
Question 38. What does SOLAS address regarding the equipment of a rescue boat compared with a lifeboat?
Your Answer: (Not answered)
Correct Answer: D (A rescue boat must carry equipment suited to its task, such as a rescue quoit, buoyant lifeline and portable VHF)
💡 SOLAS requires a rescue boat to carry equipment suited to its task, including a rescue quoit with line, a buoyant lifeline for recovery, a portable VHF and similar items, enabling it to recover a person from the water quickly.
✗
Question 39. What must be confirmed before a ship enters the ice region?
Your Answer: (Not answered)
Correct Answer: A (The ship and equipment comply with the ice class requirements)
💡 SOLAS V/12: the ship's construction, strength and equipment shall comply with the ice region requirements.
✗
Question 40. What does SOLAS address regarding automatic and remote control of propulsion machinery?
Your Answer: (Not answered)
Correct Answer: B (The control system must have the necessary alarms, monitoring and protection, retaining basic manoeuvring capability if it fails)
💡 SOLAS requires the control system of the main propulsion machinery to have alarms and monitoring, such as fault and parameter deviation alarms, and to retain basic manoeuvring capability through local control or other means if the control system fails.
✗
Question 41. What interval does SOLAS III/20 require for routine inspection of life-saving appliances?
Your Answer: (Not answered)
Correct Answer: C (At least once a week)
💡 SOLAS III/20 requires life-saving appliances to be inspected at least weekly so as to remain ready for use. Monthly inspections are the more detailed visual checks of survival craft and launching appliances.
✗
Question 42. The ship shall carry for dangerous goods:
Your Answer: (Not answered)
Correct Answer: A (a list or manifest giving the name, class and location of the goods)
💡 SOLAS VII/5 requires a special list or manifest giving the name, class and location of the dangerous goods.
✗
Question 43. What abilities must the crew demonstrate during a SIRE inspection?
Your Answer: (Not answered)
Correct Answer: C (Familiarity with the operation of equipment in their charge, their emergency duties and the relevant procedures, able to demonstrate in practice)
💡 A SIRE inspection focuses on the crew's practical command of equipment. Each member should be familiar with the equipment in his charge, the emergency procedures and the system requirements and be able to demonstrate, such as preparing a lifeboat for launching or donning a firefighter's outfit. Reciting answers will not suffice.
✗
Question 44. What must the watertight door indicator on the bridge show?
Your Answer: (Not answered)
Correct Answer: B (The open or closed status of each watertight door, with its position corresponding to the ship's arrangement)
💡 SOLAS requires the indicator on the bridge to show the open or closed status of each watertight door with its position identified to correspond with the ship's arrangement, so the watchkeeper knows exactly which door is open.
✗
Question 45. What is the purpose of the automatic closing and hold-back release arrangements of fire doors?
Your Answer: (Not answered)
Correct Answer: D (To enable the doors to be held open for passage in normal service and to close automatically on a fire alarm to maintain the fire division)
💡 Under SOLAS II-2/9 fire doors required to be self-closing should be fitted with automatic closing arrangements and, where necessary, hold-back release arrangements that release the door on detection of a fire. The door may be held open in normal service for passage and ventilation and closes automatically on a fire alarm to maintain the fire division. The arrangements should be tested regularly.
✗
Question 46. What do SOLAS and the related conventions address regarding sewage treatment systems?
Your Answer: (Not answered)
Correct Answer: D (The plant must operate and discharge in accordance with the requirements, with attention to the risk of harmful gas)
💡 A sewage treatment plant must be operated and discharge in accordance with MARPOL, and attention paid to the harmful gases which may be produced in the process. The relevant spaces should be ventilated, entry restricted and testing carried out as prescribed to prevent poisoning.
✗
Question 47. The voyage plan shall include:
Your Answer: (Not answered)
Correct Answer: A (a berth-to-berth plan giving due consideration to navigational hazards including safe speed)
💡 SOLAS V/34: the voyage plan covers the whole passage from berth to berth, giving due consideration to navigational hazards and safe speed.
✗
Question 48. What do SOLAS and good practice address regarding fuel in vehicles carried on board?
Your Answer: (Not answered)
Correct Answer: D (Fuel tanks should be kept as low as practicable and checked for leakage before loading)
💡 SOLAS and industry guidance recommend limiting the fuel in vehicles carried, normally to a stated quantity, and checking for leakage before loading, reducing fire load and the risk of spillage. The ship should take part in the check and record it.
✗
Question 49. What does SOLAS require for electrical equipment used in hazardous areas of machinery spaces?
Your Answer: (Not answered)
Correct Answer: C (It must be of a type protected against the hazard appropriate to that area)
💡 SOLAS II-1 requires electrical equipment in machinery spaces and other hazardous areas to be of a type protected against the particular hazard, so as to prevent ignition.
✗
Question 50. What are the key points in starting a lifeboat engine?
Your Answer: (Not answered)
Correct Answer: A (Prepare for starting before launching as prescribed, then start promptly after entering the water and check the cooling water discharge)
💡 Before launching, the boat engine should be prepared as the manufacturer prescribes, such as checking fuel, battery and cooling water, and started promptly once in the water with the cooling water discharge and smooth running checked, so that the boat is under control. Preparing only after entering the water delays the getaway.
✗
Question 51. A ship was found with an emergency fire pump that could not deliver water. The PSCO asked for test records. How often must the emergency fire pump be tested under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (Weekly, with the test recorded in the deck or engine log)
💡 SOLAS requires the emergency fire pump to be tested weekly to confirm it starts and delivers water, with the test recorded. Testing only at the annual survey does not ensure availability in an emergency.
✗
Question 52. Stairways penetrating more than one deck within accommodation spaces shall generally be enclosed by:
Your Answer: (Not answered)
Correct Answer: A (A class divisions)
💡 SOLAS II-2/9 requires stairways penetrating two or more decks to be enclosed by A class divisions.
✗
Question 53. Where shall the collision bulkhead be fitted and why?
Your Answer: (Not answered)
Correct Answer: B (Forward, to confine flooding from bow damage)
💡 The collision bulkhead limits flooding to the forward region after a collision.
✗
Question 54. What is required regarding preservation of the scene and records after a fire?
Your Answer: (Not answered)
Correct Answer: B (Preserve the scene, record the course of the fire and the action taken, cooperate with the investigation and analyse the cause)
💡 After a fire the scene should be preserved, with photographs where appropriate, and the time of discovery, the extent of the fire, the action taken and the result recorded truthfully. The company and the Administration should be assisted in the investigation, the cause analysed and corrective action taken to prevent recurrence.
✗
Question 55. A ship is found without a permit system or gas testing procedure for entry into enclosed spaces. The finding is?
Your Answer: (Not answered)
Correct Answer: C (A permit and testing procedure for enclosed space entry is required; absence is a serious safety deficiency)
💡 Entry into enclosed spaces requires a permit system with testing for oxygen, flammable gas and toxic gas before entry, ventilation and an attendant, in accordance with procedures. The absence of a permit and testing procedure directly threatens the lives of those entering. It is a serious safety deficiency that may normally lead to detention.
✗
Question 56. Navigation equipment shall be capable of operating:
Your Answer: (Not answered)
Correct Answer: C (with an independent supply if the main and emergency sources fail)
💡 SOLAS V/19: navigation equipment shall have an independent supply where the main and emergency sources of electrical power fail.
✗
Question 57. What do SOLAS and good practice address regarding insulation resistance of ship's electrical equipment?
Your Answer: (Not answered)
Correct Answer: A (Periodic measurement and recording of insulation resistance, investigating and rectifying any decline)
💡 SOLAS and good practice require periodic measurement and recording of insulation resistance. A fall in insulation resistance usually indicates moisture, ageing or damage, and early detection prevents short circuits and electrical fire.
✗
Question 58. Which system, directly related to fire protection, is required in accommodation and service spaces?
Your Answer: (Not answered)
Correct Answer: B (Fixed fire detection and alarm system)
💡 SOLAS II-2/12 requires fixed fire detection and alarm systems in accommodation and service spaces.
✗
Question 59. In restricted visibility, the look-out shall use:
Your Answer: (Not answered)
Correct Answer: C (Sight, hearing and all available means appropriate to the circumstances)
💡 SOLAS V/30: in restricted visibility all available means appropriate to the circumstances shall be used.
✗
Question 60. An inert gas system shall keep the oxygen content of cargo tank atmospheres below:
Your Answer: (Not answered)
Correct Answer: B (8%)
💡 SOLAS II-2/5 requires the inert gas system to maintain the oxygen content of cargo tank atmospheres below 8% by volume.
✗
Question 61. Before a towing operation, whether towing another vessel or being towed, what should be prepared in particular?
Your Answer: (Not answered)
Correct Answer: D (Check the strength and arrangement of the towline, define the towing force and means of communication, assess stability and manoeuvring safety and prepare contingency plans)
💡 Before a towing operation the strength and arrangement of the towline, including the emergency towline, should be checked, the towing force and speed determined, the manoeuvring and communication arrangements, including emergency signals, defined, the stability and manoeuvring safety of both vessels assessed and contingency plans for a towline failure prepared. A continuous lookout and communication should be maintained during the tow.
✗
Question 62. Where should the damage control plan normally be posted?
Your Answer: (Not answered)
Correct Answer: D (On the bridge)
💡 Under SOLAS II-1/19 the damage control plan should be posted on the bridge so that the navigators can quickly consult the boundaries of the compartments and the closing appliances in an emergency such as flooding. The damage control booklet is for the use of the officers.
✗
Question 63. How is a flag State expected to exercise control over ships flying its flag under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Through statutory surveys, certification and, where necessary, additional inspections)
💡 SOLAS XI-1/4 requires the flag State to exercise control through the statutory survey and certification system, with additional inspections where necessary. Reliance on PSC results alone is insufficient.
✗
Question 64. What must be handed over regarding radar and ECDIS at a watch handover?
Your Answer: (Not answered)
Correct Answer: B (The encountered situations, avoiding action taken and important information on the radar and ECDIS)
💡 At handover, the situations encountered during the watch, the avoiding action taken and important targets and warnings on the radar and ECDIS should be passed on, enabling the relieving officer to continue monitoring. Position and course alone may leave a critical risk unmentioned.
✗
Question 65. How does the survival craft requirement for a passenger ship differ from that for a cargo ship?
Your Answer: (Not answered)
Correct Answer: A (Each side must accommodate all persons, with additional liferafts for a percentage of the total number of persons)
💡 SOLAS III/21 requires each side of a passenger ship to accommodate all persons on board, with additional liferafts for a percentage of the total number of persons, so that everyone can escape if one side is unavailable.
✗
Question 66. What does SOLAS require for suction valves in watertight bulkheads?
Your Answer: (Not answered)
Correct Answer: D (Suction valves below the waterline must be capable of remote operation from above the bulkhead deck)
💡 SOLAS requires overboard and bulkhead suction valves below the waterline to be operable by remote control from above the bulkhead deck, so that they need not be operated by hand in a space which may already be flooded.
✗
Question 67. As a minimum, the flash point of fuel oil (excluding diesel lubricating oil) shall be:
Your Answer: (Not answered)
Correct Answer: B (60°C)
💡 SOLAS II-2/4.2: fuel oil, other than diesel lubricating oil, shall have a flash point of at least 60°C.
✗
Question 68. Radio antennas shall be so installed that they can operate:
Your Answer: (Not answered)
Correct Answer: A (under all weather conditions with adequate protection)
💡 SOLAS IV/13 requires radio antennas to operate under all weather conditions with adequate protection.
✗
Question 69. For a cargo ship, the pressure at any hydrant below the maximum breadth shall be not less than:
Your Answer: (Not answered)
Correct Answer: A (0.2 N/mm² (2 bar))
💡 SOLAS II-2/10 requires a pressure of not less than 0.2 N/mm² (2 bar) at any hydrant below the maximum breadth of a cargo ship.
✗
Question 70. A VHF radio installation shall maintain a continuous watch on:
Your Answer: (Not answered)
Correct Answer: A (channel 16)
💡 SOLAS IV/7: a VHF installation shall maintain a continuous watch on channel 16 and, where required, on channel 70.
✗
Question 71. What does SOLAS address regarding automatic closing devices on air pipes?
Your Answer: (Not answered)
Correct Answer: C (Automatic closing devices must be fitted, closing and remaining effective under the impact of sea water)
💡 SOLAS and the Load Line Convention require air pipes to be fitted with automatic closing devices that close and remain effective under the impact of water shipped on deck, preventing sea water from entering the tanks. A manual device alone would fail unnoticed.
✗
Question 72. Where must the equipment of a lifeboat be stowed?
Your Answer: (Not answered)
Correct Answer: C (Inside the boat in designated positions, secured to prevent loss or injury if the boat capsizes)
💡 SOLAS requires the equipment of a lifeboat to be stowed inside the boat in designated positions, such as a locker or secured by lashings, preventing loss or injury if the boat capsizes or during launching. The equipment belongs with the boat and must not be kept on the parent ship.
✗
Question 73. A port State finding deficiencies affecting safety may:
Your Answer: (Not answered)
Correct Answer: C (require rectification and, if necessary, detain the ship)
💡 SOLAS I/19 allows the port State to require rectification and detain the ship if necessary.
✗
Question 74. The bow structure requirements for bulk carriers mainly address:
Your Answer: (Not answered)
Correct Answer: B (carriage of high-density solid bulk cargoes such as ore)
💡 SOLAS XII/9: the bow structure requirements address the carriage of high-density solid bulk cargoes such as ore.
✗
Question 75. What does the ISM Code emphasise about the company's responsibility?
Your Answer: (Not answered)
Correct Answer: A (The company has overall responsibility for the safety and pollution prevention management of its ships and must provide resources and support)
💡 The ISM Code emphasises that the company bears overall responsibility for the safety and pollution prevention management of its ships and must provide the necessary resources, personnel, equipment, training and shore support, and must not shift that responsibility to the master or the crew.
✗
Question 76. While a pilot is on board, the officer of the watch should:
Your Answer: (Not answered)
Correct Answer: D (Maintain a proper look-out and monitor the pilot's actions)
💡 The OOW remains responsible and must monitor the pilot and keep a proper look-out.
✗
Question 77. Which of the following is supplied from the emergency source of power?
Your Answer: (Not answered)
Correct Answer: A (Emergency lighting, navigation lights, radio installation and steering gear related equipment, among others)
💡 SOLAS II-1/42 lists the emergency services, including emergency lighting, navigation lights, the GMDSS installation, steering gear and, where applicable, the emergency fire pump. Lighting is only one of them.
✗
Question 78. A bulk carrier's cargo hold bilge well is found blocked by cargo residue so that bilge water cannot drain. The finding is?
Your Answer: (Not answered)
Correct Answer: B (A blocked bilge well affects hold drainage and structural safety, a deficiency to be corrected)
💡 Bilge wells and the drainage system of a bulk carrier's holds are used to remove accumulated water. Blockage prevents drainage and over time may corrode the structure, increase free surface and affect stability. It is a deficiency to be corrected and the wells should be verified clear before loading.
✗
Question 79. What shall be done if radio equipment fails?
Your Answer: (Not answered)
Correct Answer: D (Repair it as soon as practicable and report as required)
💡 It shall be repaired as soon as practicable and reported as required.
✗
Question 80. What is required when life-saving appliances are changed on board?
Your Answer: (Not answered)
Correct Answer: B (Replace with approved equipment of equal or better performance and update the records and certificate attachments)
💡 Life-saving appliances should be replaced with approved equipment of the same or better performance, with the equipment records and certificate attachments such as the record of equipment for the cargo ship safety equipment certificate updated and the classification society informed for verification where necessary.
✗
Question 81. What is required for recording and reporting equipment failures?
Your Answer: (Not answered)
Correct Answer: C (Record the time, symptoms, cause and result and report to the company as the system requires)
💡 The ISM Code and SOLAS require equipment failures to be recorded, including the time, symptoms, cause, action taken and result, and reported to the company as the system requires and to the Administration or port State where necessary, as a basis for repair arrangements and improvement of the system.
✗
Question 82. Which is the 4 MHz band DSC distress frequency among the HF frequencies?
Your Answer: (Not answered)
Correct Answer: A (4207.5 kHz)
💡 HF DSC distress frequencies are 4207.5, 6312, 8414.5, 12577 and 16804.5 kHz. 2187.5 kHz is an MF frequency and 6312 kHz belongs to the 6 MHz band.
✗
Question 83. Regarding the emergency fire pump, which statement about its location is correct?
Your Answer: (Not answered)
Correct Answer: B (it shall be located outside the machinery space and its source of power shall also be outside the machinery space)
💡 SOLAS II-2/10 requires the emergency fire pump to be located outside the machinery space with its source of power also outside, to ensure water supply if the machinery space is on fire.
✗
Question 84. What does SOLAS address regarding the stowage of lifebuoys?
Your Answer: (Not answered)
Correct Answer: C (Stowed where they can be quickly released, not locked or lashed)
💡 SOLAS requires lifebuoys to be stowed so they can be released at once. Locking them or lashing them down means a lifebuoy cannot be thrown immediately when a person falls overboard, a common deficiency.
✗
Question 85. For short international voyages, the total capacity of survival craft on passenger ships may be reduced to a minimum of:
Your Answer: (Not answered)
Correct Answer: A (50%)
💡 Reductions are permitted subject to the stated minimum proportion.
✗
Question 86. What is required for checking the VDR in service?
Your Answer: (Not answered)
Correct Answer: B (Check that it is operating normally, such as correct status indication, and preserve the data as required)
💡 SOLAS requires periodic checks that the VDR is operating normally, such as correct status indication and continued recording, with the data preserved and protected as required. A VDR failure going unnoticed means key evidence is lost in an investigation.
✗
Question 87. Dangerous goods shall be stowed:
Your Answer: (Not answered)
Correct Answer: A (in accordance with the IMDG Code, with segregation to prevent dangerous reactions)
💡 SOLAS VII/3 requires stowage and segregation of dangerous goods in accordance with the IMDG Code.
✗
Question 88. What must the ship security plan contain under the ISPS Code?
Your Answer: (Not answered)
Correct Answer: A (The security organisation and duties, restricted areas, training of personnel, drills and security incident procedures)
💡 ISPS Code Part A/9 requires the ship security plan to cover the security organisation and duties, restricted areas and their control, personnel training and drills, and procedures for security incidents, subject to Administration approval.
✗
Question 89. Which sound signal does a vessel intending to ask another vessel to give way make?
Your Answer: (Not answered)
Correct Answer: A (One short blast)
💡 One short blast means altering to starboard; two prolonged followed by one short indicates a request to overtake.
✗
Question 90. What shall the design of the bridge windows ensure?
Your Answer: (Not answered)
Correct Answer: A (The officer on watch can see the forward seaway and the ship's vicinity)
💡 SOLAS V/22: the bridge must permit a good all-round view from the conning position.
✗
Question 91. After a ship is detained by PSC, what is the correct course of action?
Your Answer: (Not answered)
Correct Answer: D (Rectify the deficiencies before departure and apply for a re-inspection, fulfilling the duty to report to the flag State, the recognised organisation and the company)
💡 A detained ship should rectify the deficiencies before departure, or within the permitted period, apply for a port State re-inspection and be confirmed before leaving, and report to the flag State, recognised organisation and company as required with the rectification plan. Sailing without rectification aggravates the consequences and affects the future PSC record.
✗
Question 92. Each ship shall carry how many lifejackets for every person on board?
Your Answer: (Not answered)
Correct Answer: D (one per person)
💡 SOLAS III/7 requires one lifejacket for every person on board, with additional child lifejackets as required.
✗
Question 93. How many fire pumps are required on a passenger ship of 4000 GT and above?
Your Answer: (Not answered)
Correct Answer: D (Three)
💡 At least three.
✗
Question 94. What should be noted about the combined operation of watertight doors and the bilge system?
Your Answer: (Not answered)
Correct Answer: B (The interaction of door closure with bilge pumping should be considered, avoiding a change in heel or stability from pumping or flooding)
💡 Bilge pumping and ballast operations change the distribution of weight and the heel of the ship. They should be considered together with the open or closed state of the watertight doors, preventing pumping or flooding from increasing the list, altering stability or cross-connecting compartments, particularly when the ship is already damaged.
✗
Question 95. An inert gas system on a tanker was verified during a PSC inspection. What does SOLAS require for the oxygen content in cargo tanks?
Your Answer: (Not answered)
Correct Answer: A (It must be kept at not more than 8 per cent by volume, in accordance with the prescribed limit)
💡 SOLAS and the IBC and IGC Codes require the oxygen content of inerted cargo tanks to be kept at not more than 8 per cent by volume, so that hydrocarbon vapour cannot burn. Exceeding the limit means inerting has failed, a serious deficiency.
✗
Question 96. What does the Polar Code address regarding ice class of ships in polar waters?
Your Answer: (Not answered)
Correct Answer: A (A ship must have an ice class appropriate to the ice conditions, with action taken if conditions exceed her capability)
💡 The Polar Code requires a ship to have an ice class appropriate to the ice conditions of the intended area, categorised as A, B or C, and to take action such as altering course or stopping if conditions exceed her capability. Blindly entering ice beyond her ability is not acceptable.
✗
Question 97. The carriage of liquefied gases in bulk shall follow:
Your Answer: (Not answered)
Correct Answer: B (the International Gas Carrier Code (IGC Code))
💡 SOLAS VII/11: the carriage of liquefied gases in bulk shall follow the IGC Code.
✗
Question 98. How do the fire protection requirements for the cargo area of a chemical tanker differ from those of an oil tanker?
Your Answer: (Not answered)
Correct Answer: D (The extinguishing medium must be chosen according to the properties of the chemicals carried, with water or foam prohibited for certain cargoes)
💡 Because chemicals vary greatly in reactivity, SOLAS and the IBC Code require the extinguishing medium to suit the cargo. Some cargoes react with water or liberate toxic gas, so water or foam is prohibited.
✗
Question 99. Why must fire nozzles be of the water-fog and jet dual-purpose type?
Your Answer: (Not answered)
Correct Answer: B (spray suiting oil and electrical fires and covering the approach, the jet reaching a distance and cooling the plating)
💡 One nozzle has to serve fires of quite different kinds. On a surface of burning oil, spray covers the fire, holds off the radiation and cools the compartment, whereas a solid jet breaks the oil about and spreads the fire with it; on electrical equipment and in live spaces spray is what may be used, and then only from the distance the practice allows. A water curtain also covers the party as they close on the seat of the fire. Yet to strike from a distance, or to cool a bulkhead or a cargo surface, a solid column is wanted, which is why the nozzle changes between the two without being swapped. Sparing fresh water and ease of carrying are not the point, and calling the jet a spare misreads what the fire demands.
✗
Question 100. Electrical equipment in a hazardous area: on what is the selection made?
Your Answer: (Not answered)
Correct Answer: B (matched to the zone in type of protection and temperature class, that protection surviving maintenance)
💡 The choice rests on two things: the classification of the space, and how easily the gas or vapour there can be lit. Zones run by how often a flammable mixture may appear, equipment by type of protection and temperature class, the marking on its certificate covering the zone it is put into and its temperature class staying below the ignition temperature of what may be there. After installation, maintenance can undo all of it: a bolt left out, a flame path scored, a wrong cable gland, a housing not made by the original maker, and a certified item is uncertified in the place that matters. Testing the atmosphere before hot work or entry is a separate defence and does not substitute for the selection.