Question 1. What do SOLAS and good practice address regarding fire safety in boiler spaces?
Your Answer: (Not answered)
Correct Answer: C (Quick closing valves and ventilation shut-off arrangements, with guarding and alarms around the boiler)
💡 SOLAS requires quick closing valves and ventilation shut-off arrangements in boiler spaces, with guarding around the boiler, preventing leaking fuel from being ignited by heat. The boiler space is a high fire risk location in the machinery space.
✗
Question 2. When the ship security level is raised from level 1 to level 2, what should be done?
Your Answer: (Not answered)
Correct Answer: D (Enhanced security measures should be applied under the approved ship security plan, such as tighter access control, surveillance and checking of persons)
💡 When the security level is raised the ship should apply enhanced security measures under the approved ship security plan, such as restricted access, closer surveillance of decks and sides, checking of persons and goods and controlling passages and lighting. The master may request a higher level for local conditions.
✗
Question 3. Besides the proper shipping name, what must appear on a dangerous goods document?
Your Answer: (Not answered)
Correct Answer: C (The UN number and the hazard class)
💡 Dangerous goods documents must show the proper shipping name, UN number, class and packing group.
✗
Question 4. When is a Declaration of Security concluded?
Your Answer: (Not answered)
Correct Answer: D (When security levels differ between ship and port facility, or the interface risk is high)
💡 ISPS Code A/5: a DoS is concluded when levels differ or the security risk at the interface is high.
✗
Question 5. What checks are required after cargo operations on a tanker?
Your Answer: (Not answered)
Correct Answer: A (Confirm valves closed, lines depressurised and drained properly and the deck free of oil before standing down)
💡 After cargo operations on a tanker the procedure requires confirmation that the relevant valves are closed, the lines depressurised and drained, residual oil and drips dealt with, the deck clean and free of oil and the inert gas system normal, with a record made, before standing down, preventing danger from residual vapour.
✗
Question 6. Which of the following is NOT part of an abandon ship drill under SOLAS III/19?
Your Answer: (Not answered)
Correct Answer: C (Checking crew wage and leave records)
💡 SOLAS III/19 lists summoning of persons, checking dress and lifejackets, briefing and operation of launching appliances and checking equipment readiness. Wage and leave records are not part of a drill.
✗
Question 7. Regarding the master's duties, which is correct?
Your Answer: (Not answered)
Correct Answer: D (the master has ultimate responsibility for safe navigation and shall take charge when necessary)
💡 SOLAS V/34: the master has ultimate responsibility for safe navigation and shall take charge when necessary.
✗
Question 8. What watch must be maintained after a distress alert is transmitted?
Your Answer: (Not answered)
Correct Answer: A (A watch on the appropriate distress frequency, ready to answer and establish communication)
💡 After transmitting a distress alert the ship should keep a watch on the appropriate distress and safety frequency, such as VHF channel 16, MF 2182 kHz or the satellite equipment, ready to answer other ships or coast stations, so that distress traffic can be established and assistance obtained as quickly as possible.
✗
Question 9. For a ship with periodically unattended machinery spaces, what does SOLAS require regarding alarms?
Your Answer: (Not answered)
Correct Answer: A (An alarm system automatically transmitting alarms to the bridge or the engineers' accommodation)
💡 A ship with periodically unattended machinery spaces must have an alarm system that automatically transmits machinery faults and abnormalities to the bridge or the engineers' accommodation, ensuring safe operation without attendance.
✗
Question 10. Where shall the muster stations designated in the muster list be located?
Your Answer: (Not answered)
Correct Answer: B (Near the survival craft embarkation stations and readily accessible)
💡 Near the embarkation stations and readily accessible.
✗
Question 11. What is the purpose of heading repeaters for the gyro compass?
Your Answer: (Not answered)
Correct Answer: B (To repeat the heading at positions where it is needed, such as the steering and emergency steering positions)
💡 SOLAS requires heading repeaters at the main steering and emergency steering positions so that the helmsman can read the heading without leaving his station, ensuring accurate steering.
✗
Question 12. Which of the following are common types of fixed fire detection systems?
Your Answer: (Not answered)
Correct Answer: A (Smoke, heat and flame (radiation) detectors)
💡 SOLAS recognises fixed detection systems including smoke, heat and flame (radiation) types, selected according to the nature of the space and the fire characteristics expected.
✗
Question 13. What size should the international shore connection fitted on ships of 500 GT and above be?
Your Answer: (Not answered)
Correct Answer: A (65 mm)
💡 The international shore connection is 65 mm in diameter.
✗
Question 14. How do hinged and sliding watertight doors differ in use while the ship is at sea?
Your Answer: (Not answered)
Correct Answer: C (the hinged door shut before the ship leaves port and kept shut at sea, while a sliding door permitted to be used may be closed at any moment from the bridge and from either side)
💡 The line is drawn not by which way the door swings or how fast it shuts, but by whether it may be standing open at sea. A hinged door, open, leaves the bulkhead doing nothing, so it is to be shut before the ship parts from the port and kept shut on the voyage. A power slide sits where people must pass, so it is allowed to work at sea where permission covers it, on the terms that it can be closed at any moment from the bridge and from either side of it, that the closing has a sound and a indication, that lamps show where the door stands, that it is tested at intervals and written up, and that a document on board says which doors may be used at sea and when they must be closed, the master seeing it carried out before sailing. Whether the indication, the alarm and the local control work is a common thing to test in an inspection and in a drill; to treat it as long as somebody keeps an eye on it is the opposite of the requirement.
✗
Question 15. Ships shall be provided with heading indication by means of:
Your Answer: (Not answered)
Correct Answer: D (a gyro-compass or magnetic compass providing heading indication on the bridge)
💡 SOLAS V/19 requires heading indication equipment providing heading to the bridge.
✗
Question 16. How many firefighter's outfits must a cargo ship of 1000 GT and above carry?
Your Answer: (Not answered)
Correct Answer: C (At least two)
💡 SOLAS II-2/10.10 requires at least two firefighter's outfits on cargo ships of 1000 GT and above. Tankers are additionally required to carry extra outfits, normally four.
✗
Question 17. What is the main purpose of the main engine and steering gear information required on board?
Your Answer: (Not answered)
Correct Answer: B (To enable the master to know the machinery and steering response and plan safe manoeuvres)
💡 SOLAS requires information on the main engine and steering gear so the master understands acceleration, deceleration and steering response, and can plan berthing and narrow channel manoeuvres.
✗
Question 18. When a ship changes flag, which is required?
Your Answer: (Not answered)
Correct Answer: D (Both the former and new flag States must recognise the ship's safety status)
💡 Flag change requires formal recognition of safety status by both the former and new flag States.
✗
Question 19. What additional look-out does SOLAS require at night or in restricted visibility?
Your Answer: (Not answered)
Correct Answer: A (An additional look-out posted and a sharp listening watch, using all available means as necessary)
💡 SOLAS and COLREG require an additional look-out, sharp visual and auditory watch and full use of radar and all available means at night, in restricted visibility or in dense traffic. Daylight standards are not sufficient.
✗
Question 20. Under the ISPS Code, which security officer must be designated on board?
Your Answer: (Not answered)
Correct Answer: C (Ship Security Officer)
💡 ISPS Code A/11 requires a Ship Security Officer to be designated on board.
✗
Question 21. The steering gear takes 35 seconds to move the rudder from 35 degrees one side to 30 degrees the other. What is the finding?
Your Answer: (Not answered)
Correct Answer: B (It exceeds the prescribed 28 seconds and does not comply; the steering gear performance must be investigated)
💡 SOLAS II-1/29 requires the main steering gear, at maximum service speed and deepest seagoing draught, to complete the movement from 35 degrees one side to 30 degrees the other within 28 seconds. Thirty five seconds exceeds the limit and indicates a problem with the power or control capability of the steering gear.
✗
Question 22. What does SOLAS require regarding the establishment of safe working practices on board?
Your Answer: (Not answered)
Correct Answer: D (Appropriate systems and procedures must be established and followed so that personnel perform their duties to a consistent standard)
💡 SOLAS V/14 requires systems and procedures for safe working practices, covering bridge procedures, anchor watch, machinery operation and emergency procedures, ensuring consistent and safe operation.
✗
Question 23. What does SOLAS address regarding level measurement and alarms for fuel and lubricating oil tanks?
Your Answer: (Not answered)
Correct Answer: B (Level measuring arrangements, with high level alarms where overflow is possible, preventing spillage)
💡 SOLAS requires fuel and lubricating oil tanks to be provided with level measuring arrangements and, where overflow is possible, high level alarms, preventing spillage during bunkering or transfer which would create a fire hazard and pollution.
✗
Question 24. For power-operated sliding watertight doors, control shall be possible from:
Your Answer: (Not answered)
Correct Answer: C (both the navigation bridge and a position above the bulkhead deck)
💡 SOLAS II-1/10 requires power-operated sliding watertight doors to be operable from the navigation bridge and from a position above the bulkhead deck, as well as locally.
✗
Question 25. Bulk carriers of 150 m and above must be fitted with a loading instrument. What is its purpose?
Your Answer: (Not answered)
Correct Answer: A (To calculate hull stress and intact stability during loading and unloading)
💡 SOLAS XII/11 requires the loading instrument for calculating hull stresses and intact stability during cargo work, preventing structural damage from overloading or incorrect sequence. Water level detection is a separate requirement.
✗
Question 26. When navigating in polar waters, what should be paid particular attention to under the Polar Code?
Your Answer: (Not answered)
Correct Answer: A (The effects of low temperature on equipment and personnel, ice conditions and ice class, and the procedures and limitations in the Polar Ship's Operational Manual)
💡 The polar environment is special, so particular attention should be paid to the effects of low temperature on equipment such as life-saving appliances, firefighting, fuel and hydraulic systems and on personnel, to ice conditions and the ship's ice class limits, and to the operational procedures and limitations in the Polar Ship's Operational Manual, with specific training and preparation carried out.
✗
Question 27. What is the sequence of immediate actions after a person falls overboard?
Your Answer: (Not answered)
Correct Answer: A (Throw a lifebuoy on the side of the casualty at once, sound the man overboard alarm, inform the bridge and carry out the turning manoeuvre)
💡 The standard response to a person overboard is to throw a lifebuoy with light and smoke on the side of the casualty at once, press the man overboard alarm, inform the bridge and carry out the practised turning manoeuvre to return to the position as quickly as possible, with a person detailed to keep the casualty in sight.
✗
Question 28. What checking is required of the electrical insulation of firefighter's boots?
Your Answer: (Not answered)
Correct Answer: C (Check the soles for damage, perforation and loss of insulating properties, replacing them at once if defective)
💡 Firefighter's boots should be checked for damage, perforation, ageing and loss of insulating properties in the soles. Damaged boots expose the firefighter to injury in a live electrical or high temperature environment and must be replaced at once, forming part of the routine inspection of the outfit.
✗
Question 29. What does SOLAS address regarding the remote control system of the main engine?
Your Answer: (Not answered)
Correct Answer: C (The main engine must be controllable from the bridge and the machinery control room, with reliable transfer between positions with indication and alarms)
💡 SOLAS requires the main engine to be controllable from both the bridge and the machinery control room, with reliable transfer between control positions and appropriate indication and alarms, preventing loss of control or misoperation during transfer.
✗
Question 30. On what band does a SART operate?
Your Answer: (Not answered)
Correct Answer: C (9 GHz (X band))
💡 It operates on 9 GHz (X band) so as to be detected by radar.
✗
Question 31. What is checked regarding the donning of personal equipment in a fire drill?
Your Answer: (Not answered)
Correct Answer: A (That the firefighter's outfit is correctly worn, the breathing apparatus airtight and communication working)
💡 A fire drill should check that the firefighter's outfit is correctly worn, including helmet, protective clothing, boots and gloves, that the breathing apparatus face mask is airtight and tested and that communication between the team members and with the bridge works, so that actual operations are safe and effective.
✗
Question 32. What shall fuel oil tank level gauging comply with?
Your Answer: (Not answered)
Correct Answer: A (Devices that do not endanger fire safety)
💡 Gauging shall not endanger fire safety; glass tube gauges are prohibited for such use.
✗
Question 33. A lifejacket light shall be capable of continuous operation for at least:
Your Answer: (Not answered)
Correct Answer: C (8 hours)
💡 SOLAS III/7 (LSA Code) requires a lifejacket light to operate continuously for at least 8 hours.
✗
Question 34. The navigation lights are found not to meet the required position, colour or arc of visibility. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Non-compliant navigation lights affect the ability of other ships to judge the situation, a deficiency to be corrected)
💡 The position, colour and arc of visibility of the navigation lights, such as masthead, sidelights and stern light, must meet the requirements so that other ships can judge the heading and movement of the vessel from the correct bearing and distance. Non-compliance may lead to misjudgement and increased risk of collision. It is a deficiency to be corrected.
✗
Question 35. What does SOLAS address regarding ventilation of paint and flammable liquid lockers?
Your Answer: (Not answered)
Correct Answer: C (Independent mechanical ventilation capable of effectively removing flammable vapour)
💡 SOLAS requires paint and flammable liquid lockers to have independent mechanical ventilation effectively removing flammable vapour, preventing accumulation and ignition. Sharing ventilation with accommodation would carry toxic vapour into the living spaces.
✗
Question 36. For how long shall a VDR retain its recorded data as a minimum?
Your Answer: (Not answered)
Correct Answer: B (12 hours)
💡 SOLAS V/20: the VDR shall retain at least the last 12 hours of data.
✗
Question 37. What are the requirements on the use of the emergency steering position?
Your Answer: (Not answered)
Correct Answer: A (steering taken on there quickly when bridge control fails, communication with the bridge kept, and the crew made familiar with the position and its handling by drill)
💡 The emergency position is in the steering gear space and exists so the ship can still be steered when control from the bridge has failed. It must be lit and fed from a supply that does not depend on the main source, have a sound means of communication with the bridge, show the position of the rudder, and be operated in a way the person on watch can take at once, direct control of the valves or the gear as the case may be, after practice. The drill programme covers the changeover from bridge control and how long it takes. To leave the work to the engineer alone with the officer writing down times, or to treat the position as a drill item never to be used in earnest, misses what it is there for.
✗
Question 38. What does SOLAS address regarding air pipes?
Your Answer: (Not answered)
Correct Answer: B (Air pipes must have effective closing appliances and adequate height to prevent water entering the tanks)
💡 SOLAS and the Load Line Convention prescribe the height and closing appliances of air pipes, so that water does not enter tanks when the deck is swept by seas or the ship lists, preventing loss of stability.
✗
Question 39. Which principle applies to the stowage of survival craft?
Your Answer: (Not answered)
Correct Answer: D (They must be readily available and capable of being launched and boarded rapidly and safely in an emergency)
💡 Under SOLAS III/13 survival craft should be stowed in a position where they are readily available and can be launched and boarded rapidly and safely, protected from the effects of fire and explosion, the arrangement of the craft and their launching and boarding appliances ensuring that in an emergency persons can muster, board and clear quickly.
✗
Question 40. What does SOLAS address regarding marking of escape routes?
Your Answer: (Not answered)
Correct Answer: C (Clear marking identifiable in dense smoke, indicating the way to muster and embarkation stations)
💡 SOLAS requires escape routes to be clearly marked in a form identifiable in dense smoke, such as low level lighting or photoluminescent markings, showing the way to the muster and embarkation stations so that personnel can find the exit in very poor visibility.
✗
Question 41. Which ships shall be fitted with a VDR?
Your Answer: (Not answered)
Correct Answer: A (Passenger ships and cargo ships of 3000 GT and above)
💡 Passenger ships and cargo ships of 3000 GT and above.
✗
Question 42. Which channel is used for VHF DSC distress alerting?
Your Answer: (Not answered)
Correct Answer: B (Channel 70)
💡 VHF DSC distress and calling use channel 70, which is not used for speech. Channel 16 is for radiotelephony distress and safety traffic.
✗
Question 43. For how long shall the emergency source of power on a passenger ship be capable of supplying the emergency services?
Your Answer: (Not answered)
Correct Answer: B (36 hours)
💡 SOLAS II-1/42: 36 hours on passenger ships; 18 hours on cargo ships.
✗
Question 44. Sea area A2 means an area, excluding sea area A1, within the coverage of at least one:
Your Answer: (Not answered)
Correct Answer: C (MF coast station with continuous alerting capability)
💡 SOLAS IV/2: Sea area A2 is the area, excluding A1, within the coverage of at least one MF coast station with continuous DSC alerting.
✗
Question 45. Which equipment does a ship in sea area A3 use to receive maritime safety information and satisfy GMDSS?
Your Answer: (Not answered)
Correct Answer: A (An enhanced group calling (EGC) receiver)
💡 Beyond NAVTEX coast station coverage, a ship in sea area A3 must use EGC to receive SafetyNET MSI. NAVTEX is available only within A1 and A2 coverage.
✗
Question 46. What is the risk if a crew member answers vaguely when asked about equipment operation?
Your Answer: (Not answered)
Correct Answer: D (It raises doubt about training and the effective operation of the system and may lead to a deeper inspection)
💡 A vague answer about equipment or emergency duties indicates that training and familiarisation may not be effective. The inspector will go deeper, including asking for practical demonstrations and checking records, and may find that the system is not effectively implemented.
✗
Question 47. What does a B-15 class division mean?
Your Answer: (Not answered)
Correct Answer: D (It prevents the passage of flame and limits temperature rise for 15 minutes in the standard fire test)
💡 Class B divisions are graded B-15 and B-0, the figure being the period in minutes for which temperature rise is limited in the standard fire test. Class B divisions are of non-combustible material, preventing passage of flame with lower strength than class A.
✗
Question 48. After a renewal survey is completed, what must the Administration or recognised organisation do with the certificate?
Your Answer: (Not answered)
Correct Answer: C (Issue a new certificate stating completion of the survey and the period of validity)
💡 SOLAS requires a new certificate to be issued after a renewal survey, stating the date of completion and the period of validity. Extending the old certificate or leaving the master to enter dates does not comply.
✗
Question 49. What do SOLAS and the IMO circulars address regarding prevention of accidents in drills?
Your Answer: (Not answered)
Correct Answer: B (Use tested launching gear and the correct handling procedure, avoiding hazardous practices in drills)
💡 Having reviewed a number of fatal accidents in drills, the IMO circulars require tested release gear, strict adherence to launching and recovery procedures, protection and coordination of personnel and avoidance of hazardous practices for the sake of realism, particularly in the operation of lifeboat release gear.
✗
Question 50. What should be done with firefighter's outfits after use?
Your Answer: (Not answered)
Correct Answer: D (Clean, dry, inspect for damage and return to stowage, replacing defective parts promptly)
💡 After use, including in drills, firefighter's outfits should be cleaned, dried and inspected for damage such as torn clothing, low cylinder pressure or perished face masks, with defective parts replaced and the outfit returned to its stowage, ready for the next use.
✗
Question 51. A ship is 180 m in length. What is the minimum number of lifebuoys under SOLAS III/7.1?
Your Answer: (Not answered)
Correct Answer: A (18)
💡 SOLAS III/7.1 sets bands by length: under 60 m — 8; 60 to 120 m — 12; 120 to 180 m inclusive — 18; over 180 m — 24. A length of 180 m falls in the third band.
✗
Question 52. What loading limitation must be observed when a bulk carrier loads high density cargo?
Your Answer: (Not answered)
Correct Answer: D (Limits on the maximum weight in each hold and on differences between adjacent holds, preventing excessive local stresses)
💡 Concentrated high density cargo overstresses the tank top and double bottom. SOLAS and the IMSBC Code require limits on the maximum weight per hold and on differences between adjacent holds to be observed. Limiting deadweight alone does not protect the structure.
✗
Question 53. What corridor length limit does SOLAS address in the escape requirements for accommodation spaces?
Your Answer: (Not answered)
Correct Answer: B (An enclosed corridor exceeding 13 m must have escape routes at both ends)
💡 SOLAS II-2/13 requires an enclosed corridor more than 13 m long to have access to escape routes at both ends, so that persons are not trapped in a long corridor with a single exit.
✗
Question 54. What measures shall be taken for cargo liable to spontaneous combustion?
Your Answer: (Not answered)
Correct Answer: A (Temperature monitoring and ventilation)
💡 Monitoring of temperature with ventilation and, if necessary, early discharge.
✗
Question 55. After grounding, what should the master give priority to?
Your Answer: (Not answered)
Correct Answer: D (Ascertain the extent of flooding and damage, assess stability and pollution risk, prevent further damage and pollution and report)
💡 After grounding the first priority is to ascertain the flooding of compartments, the damage to the hull and the ship's position, assess stability, the grounding forces and the pollution risk, and take measures to prevent further damage and pollution, such as closing watertight doors, controlling draught and trim, informing those concerned and reporting. Forcing a refloat at once may worsen the damage and must be carefully assessed.
✗
Question 56. What is required of machinery space fans in a fire?
Your Answer: (Not answered)
Correct Answer: A (Capable of being stopped promptly and ventilation closed from outside)
💡 Fans shall be capable of prompt stopping and ventilation closed from outside.
✗
Question 57. What does the daily check of radio equipment require under SOLAS IV/13 and the performance standards?
Your Answer: (Not answered)
Correct Answer: D (Daily checks of the equipment with a record of whether it functions correctly)
💡 SOLAS IV/13 and the GMDSS performance standards require daily checks of radio equipment, such as DSC self-tests and battery voltage, with a record kept, keeping the equipment in a state of readiness.
✗
Question 58. In a narrow channel, a vessel engaged in fishing shall not impede:
Your Answer: (Not answered)
Correct Answer: A (any other vessel which can navigate only within the narrow channel)
💡 SOLAS V/27: in a narrow channel, a vessel engaged in fishing shall not impede any vessel which can navigate only within that channel.
✗
Question 59. What important items should be taken when abandoning ship?
Your Answer: (Not answered)
Correct Answer: C (The deck log, copies of certificates, the crew list, emergency radio equipment and essential supplies)
💡 Where possible the deck log, certificates or copies, the crew list, emergency radio equipment such as the EPIRB and portable VHF and essential food, water and medicines should be taken, as these are vital for subsequent search and rescue and for investigation.
✗
Question 60. A 120 m cargo ship has one lifeboat on each side. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (The capacity on each side must accommodate all persons, with at least one boat serving as a rescue boat)
💡 SOLAS requires the capacity on each side of a cargo ship to accommodate all persons on board, with at least one boat meeting the rescue boat requirements. Counting the two boats together would not ensure escape if one side were lost.
✗
Question 61. What do SOLAS and good practice address regarding operational testing of a fixed foam system?
Your Answer: (Not answered)
Correct Answer: C (Periodic inspection of piping and nozzles and, as required, a discharge test to confirm the system works)
💡 SOLAS and good practice require periodic inspection of the piping, valves and nozzles of a fixed foam system for obstruction, with a discharge test as required, confirming that the system will operate when needed.
✗
Question 62. What does SOLAS require for the maintenance and testing of radio equipment?
Your Answer: (Not answered)
Correct Answer: A (Regular testing with records kept so that the equipment remains ready for use at all times)
💡 SOLAS IV/15 requires prescribed daily and periodic tests with records kept, keeping the equipment in a state of readiness. Waiting for the annual survey is not sufficient.
✗
Question 63. High-velocity vent valves of a tanker cargo tank venting system shall have a gas discharge velocity of not less than:
Your Answer: (Not answered)
Correct Answer: D (30 m/s)
💡 SOLAS II-2/4 requires high-velocity vent valves to discharge at a velocity of not less than 30 m/s.
✗
Question 64. What do SOLAS and good practice address regarding monitoring hull deformation during cargo work on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: B (Monitoring hogging and sagging to prevent deformation exceeding the permitted range)
💡 SOLAS and good practice require hogging and sagging to be monitored during cargo work on a bulk carrier, judging from the loading instrument or draught readings whether stresses are within limits, preventing structural damage from excessive deformation.
✗
Question 65. Where a machinery space is provided with two means of escape, they shall:
Your Answer: (Not answered)
Correct Answer: C (be as widely separated as possible)
💡 SOLAS II-2/13 requires the two means of escape to be as widely separated as possible.
✗
Question 66. For a ship with no emergency generator, for how long shall the GMDSS reserve source of energy supply?
Your Answer: (Not answered)
Correct Answer: C (6 hours)
💡 SOLAS IV/13: the reserve source shall be capable of supplying for 6 hours on ships without an emergency generator.
✗
Question 67. In restricted visibility, which measure is NOT in accordance with SOLAS?
Your Answer: (Not answered)
Correct Answer: D (accelerate to pass through quickly)
💡 SOLAS V/8: in restricted visibility measures such as reducing speed, using radar and keeping a proper lookout shall be taken; accelerating is not permitted.
✗
Question 68. For how long at least should the backup power of an ECDIS keep it working?
Your Answer: (Not answered)
Correct Answer: B (At least thirty minutes)
💡 Under SOLAS V/19.2.6 an ECDIS should have a backup power supply able to keep it working for at least thirty minutes if the main or emergency source fails, so that essential navigational information is not interrupted. The condition of the backup supply such as a UPS should be included in checks and maintenance.
✗
Question 69. What must the cargo securing manual contain under SOLAS VI/5 and the CSS Code?
Your Answer: (Not answered)
Correct Answer: C (Securing methods for the various cargo units, specifications of securing equipment and methods of strength verification)
💡 SOLAS VI/5 and the CSS Code require the cargo securing manual to contain the securing methods for the various cargo units, the specification and number of securing devices, methods of strength verification and inspection requirements, for correct securing by the crew.
✗
Question 70. Fuel oil used in machinery spaces shall generally have a flash point (closed cup) of not less than:
Your Answer: (Not answered)
Correct Answer: A (60 °C)
💡 SOLAS II-2/4 generally requires a flash point of not less than 60 °C, except emergency generators may use fuel with a flash point of not less than 43 °C.
✗
Question 71. How shall portable extinguishers be positioned?
Your Answer: (Not answered)
Correct Answer: A (Readily accessible within the space without obstructing escape)
💡 They shall be readily accessible without impeding escape.
✗
Question 72. How is the meteorological service addressed in SOLAS V?
Your Answer: (Not answered)
Correct Answer: A (Contracting Governments undertake to provide meteorological information and warnings to ships)
💡 SOLAS V/5 requires Contracting Governments to provide meteorological information and warnings to ships, which masters use in planning the voyage.
✗
Question 73. Which audible signalling device must be attached to a lifejacket?
Your Answer: (Not answered)
Correct Answer: D (A whistle)
💡 SOLAS III/7.1 requires a whistle secured by a cord to each lifejacket. A horn is not the required appliance.
✗
Question 74. What analysis of accidents and near misses is required?
Your Answer: (Not answered)
Correct Answer: D (Report and analyse the root cause, take corrective action, assess the outcome and share the lesson)
💡 The ISM Code requires accidents and near misses, events that could have caused loss, to be reported and analysed for root cause, with corrective and preventive action taken, effectiveness assessed and the lesson shared on board and within the company, so that the warning is used and a near miss does not become an accident.
✗
Question 75. An International Ship Security Certificate (ISSC) shall be issued for a period not exceeding:
Your Answer: (Not answered)
Correct Answer: C (5 years)
💡 SOLAS XI-2/3: an International Ship Security Certificate shall be issued for a period not exceeding 5 years.
✗
Question 76. What is required for meeting and overtaking arrangements in a narrow channel?
Your Answer: (Not answered)
Correct Answer: D (Coordinate the manner of passing with the other vessel or the vessel to be overtaken by VHF in advance, agreeing who gives way and on which side)
💡 Meeting and overtaking in a narrow channel should be coordinated in advance by VHF with the other vessel, agreeing the manner of passing and the responsibility to give way, with local requirements such as one-way periods observed, reducing misunderstanding and close-quarters situations.
✗
Question 77. What is the minimum period for which the emergency source of power of a cargo ship should supply the emergency load?
Your Answer: (Not answered)
Correct Answer: A (Eighteen hours)
💡 Under SOLAS II-1/42 the emergency source of power of a cargo ship should supply the specified emergency load for at least eighteen hours, thirty-six hours for a passenger ship, so that emergency lighting, steering gear, communications and alarms continue after a blackout.
✗
Question 78. A new chief officer needs to familiarise himself with the damage control plan. Where does SOLAS II-1/23 require it to be permanently exhibited?
Your Answer: (Not answered)
Correct Answer: B (On the navigation bridge, in the cargo control room and at the damage control station)
💡 SOLAS II-1/23 requires the damage control plan to be permanently exhibited at the positions where it will be needed, including the navigation bridge, cargo control room and damage control station.
✗
Question 79. Why should the length and diameter of fire hoses meet the requirements?
Your Answer: (Not answered)
Correct Answer: B (To ensure the hose reaches the protected space, is easy to handle and does not affect discharge pressure)
💡 A fire hose should be of appropriate length and diameter: too long increases friction loss and reduces pressure, too short cannot reach the protected space. Every hydrant's hose should reach any position in the protected space requiring it and be suitable for operation by two persons.
✗
Question 80. What measures must be taken when shipping a bulk cargo which may release toxic or flammable gas?
Your Answer: (Not answered)
Correct Answer: B (Increased ventilation, gas testing and restriction of entry into the holds as necessary)
💡 The IMSBC Code and SOLAS require increased ventilation and gas testing for cargoes that may release toxic or flammable gas, and gas testing with an entry permit before anyone enters a hold, preventing poisoning and explosion.
✗
Question 81. What do SOLAS and the CSS Code address regarding deck cargo?
Your Answer: (Not answered)
Correct Answer: D (Deck loads must be checked against deck strength and their effect on stability, with securing under the securing manual)
💡 SOLAS requires the local strength of the deck and the effect on stability and freeboard to be checked when carrying cargo units on deck, with securing and protection in accordance with the securing manual, preventing overloading or loss of cargo overboard.
✗
Question 82. How often shall abandon ship and liferaft drills be held on a cargo ship?
Your Answer: (Not answered)
Correct Answer: A (Monthly)
💡 SOLAS III/19: such drills shall take place at least once a month on cargo ships.
✗
Question 83. For a tanker fitted with an inert gas system, the deck foam system application rate shall be not less than:
Your Answer: (Not answered)
Correct Answer: C (1.0 L/min·m²)
💡 SOLAS II-2/20 requires the foam application rate to be not less than 1.0 L/min·m² for tankers with an inert gas system.
✗
Question 84. After an accidental DSC distress alert is transmitted, what is the correct action?
Your Answer: (Not answered)
Correct Answer: A (Immediately transmit a cancellation to the relevant coast station or RCC)
💡 SOLAS and ITU procedures require an accidental alert to be cancelled immediately by a follow-up message to the coast station or rescue coordination centre. It must never be ignored.
✗
Question 85. What safety is required in spaces adjacent to a hold containing cargo that may release harmful gas?
Your Answer: (Not answered)
Correct Answer: B (Monitor gas concentrations in adjacent spaces such as enclosed passages and stores, preventing gas ingress)
💡 For cargoes that may release harmful or flammable gas, the IMSBC Code requires monitoring not only inside the hold but also the possibility of gas entering adjacent enclosed spaces such as passages, stores and the machinery space through bulkheads, piping and access ways, preventing poisoning or the ignition of the gas.
✗
Question 86. Within what period before departure shall the steering gear be tested?
Your Answer: (Not answered)
Correct Answer: C (Within 12 hours)
💡 SOLAS V/25: the steering gear shall be tested within 12 hours before departure.
✗
Question 87. With regard to the stability of a grain-laden ship:
Your Answer: (Not answered)
Correct Answer: C (the effect of grain shift shall be considered and the Grain Code stability requirements met)
💡 SOLAS VI/6 requires consideration of grain shift and compliance with the International Grain Code stability requirements.
✗
Question 88. What shall embarkation arrangements for survival craft ensure?
Your Answer: (Not answered)
Correct Answer: D (Rapid and orderly boarding and ease of launching)
💡 They shall permit rapid, orderly embarkation and launching.
✗
Question 89. What is the basic principle for the provision of lifejackets?
Your Answer: (Not answered)
Correct Answer: D (One for every person on board, with additional ones for watchkeepers, remote locations and survival craft stations)
💡 Under SOLAS III/7 and III/32 a lifejacket should be provided for every person on board, with additional ones to meet the needs of watchkeeping positions, remote locations and survival craft stations, so that one can be obtained at any time and place.
✗
Question 90. What is the relationship between an extension and a short-term certificate?
Your Answer: (Not answered)
Correct Answer: B (An extension applies where a certificate expires during a voyage; a short-term certificate is issued to enable the ship to reach a port of survey or for another specific purpose)
💡 An extension under SOLAS is a remedy where a certificate expires during a voyage before survey can be carried out, while a short-term certificate is issued for a limited period to enable the ship to reach the port of survey or for another specific purpose. The situations differ and neither may replace the full certificate long term.
✗
Question 91. A ship has double side skin, a single deck, top side tanks and hopper side tanks and carries ore in bulk. What is she under SOLAS XII/1?
Your Answer: (Not answered)
Correct Answer: D (A bulk carrier subject to the requirements of Chapter XII)
💡 SOLAS XII/1 defines a bulk carrier as a ship with a single deck, top side tanks and hopper side tanks intended primarily to carry dry cargo in bulk. An ore carrier meets the definition and must comply with Chapter XII.
✗
Question 92. What should be done if insulation on a fire division becomes damp, falls off or is removed?
Your Answer: (Not answered)
Correct Answer: D (Repair or replace promptly to restore the fire rating, using approved material)
💡 Damp, missing or removed insulation on a class A division reduces its fire performance and should be replaced promptly with approved material to restore the original rating. Substituting ordinary material or timber destroys the protective function of the division.
✗
Question 93. What is the principal characteristic of class 7 dangerous goods?
Your Answer: (Not answered)
Correct Answer: B (Radioactive material, presenting ionising radiation hazards)
💡 Class 7 of the IMDG Code covers radioactive material, whose carriage requires packaging, marking, segregation and personnel exposure to be controlled in accordance with radiation protection requirements. Corrosives are class 8 and miscellaneous dangerous substances class 9.
✗
Question 94. When clear grounds are found during a PSC inspection, what is the next step?
Your Answer: (Not answered)
Correct Answer: A (A more detailed inspection, with detention if deficiencies are serious)
💡 PSC procedures require a more detailed inspection where clear grounds exist. Detention follows only where deficiencies are clearly hazardous; PSCOs do not normally fine ships or withdraw certificates directly.
✗
Question 95. What should be noted about launching lifeboats while the ship has headway?
Your Answer: (Not answered)
Correct Answer: A (Reduce speed or stop if possible before launching, avoiding the boat being swept away or striking the hull)
💡 A lifeboat should be launched with speed reduced or the ship stopped where possible, since headway produces a flow that can sweep the boat away or dash it against the hull. If stopping is impossible in an emergency, the boat should be launched on the lee side with due preparation.
✗
Question 96. What must the PWOM contain regarding operational measures for polar waters?
Your Answer: (Not answered)
Correct Answer: A (Ice assessment in voyage planning, ship capability limitations, emergency procedures and training requirements)
💡 The Polar Water Operational Manual must cover voyage planning, ice assessment, the ship's ice class capabilities and limitations, operation of equipment in low temperature, emergency procedures and training, guiding the master's decisions in ice.
✗
Question 97. What securing is required for vehicles carried as ro-ro cargo?
Your Answer: (Not answered)
Correct Answer: A (Secure using the lashings or chains specified in the securing manual, confirming brake and gear status)
💡 SOLAS and the CSS Code require ro-ro cargo to be secured with the lashing straps, chains or dedicated devices specified in the securing manual, with the vehicle confirmed braked and in a suitable gear and its fuel and battery condition acceptable, preventing movement and collision during the voyage.
✗
Question 98. Which certificates may a recognized organization issue on behalf of the Administration?
Your Answer: (Not answered)
Correct Answer: A (Statutory certificates such as the Passenger Ship Safety Certificate)
💡 A recognized organization may be entrusted with statutory surveys and certification.
✗
Question 99. A PSC inspection found the container holding the fire control plan had taken water and the plan was illegible. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (The plan must be kept in a conspicuously marked weathertight container and remain clear and legible)
💡 SOLAS II-2/15 requires the fire control plan to be permanently stowed in a conspicuously marked weathertight enclosure outside the deckhouse and to remain complete and legible so shore firefighters can use it quickly. Damage to the plan is a deficiency.
✗
Question 100. A survey found the nautical publications on board out of date. What does SOLAS address?
Your Answer: (Not answered)
Correct Answer: C (A deficiency; publications must be kept corrected up to date, as out-of-date information affects safety of navigation)
💡 SOLAS V/27 requires charts and nautical publications to be kept corrected to the latest information and they are checked at survey. Out-of-date publications are a deficiency affecting safety of navigation, particularly in confined waters and on an unfamiliar coast, where they create a risk of grounding.