Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. What is the principle for the inspection and maintenance of portable fire extinguishers?
Your Answer: (Not answered)
Correct Answer: B (Their pressure, seals, nozzles and securing should be checked regularly, with maintenance or recharging at the required intervals and records kept)
💡 Under SOLAS II-2/10 and the maintenance requirements portable fire extinguishers should have their pressure indication, seals, nozzles and securing checked regularly and be maintained or recharged at the required intervals, by an approved service provider where applicable, with records kept, ensuring they are always available.
✗
Question 2. Which high risk areas do SOLAS and the ESP require to be examined on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Hatch covers, the internal structure of top side and hopper side tanks and the corrosion and cracking of bulkheads and side structure)
💡 The ESP and SOLAS require close-up examination and thickness measurement of hatch covers, the internal structure of top side and hopper side tanks and the stiffening of bulkheads and sides, since these areas corrode readily and directly affect the longitudinal strength of the hull.
✗
Question 3. Before proceeding to sea, the ship shall be:
Your Answer: (Not answered)
Correct Answer: A (ensured to be in all respects seaworthy, including adequate stability and trim)
💡 SOLAS V/34: before proceeding to sea the ship shall be ensured to be in all respects seaworthy, including adequate stability and trim.
✗
Question 4. What fire protection is required in the cargo area of a gas carrier?
Your Answer: (Not answered)
Correct Answer: A (Gas detection and alarm, intrinsically safe or explosion-protected electrical equipment and safety devices protecting the cargo containment system)
💡 SOLAS and the IGC Code require the cargo area of a gas carrier to have flammable gas detection and alarm, intrinsically safe or explosion-protected electrical equipment and devices protecting the pressure and temperature of the cargo containment system, preventing accumulation of leaks and overpressure.
✗
Question 5. What does SOLAS and the related rules address regarding cargo ventilation?
Your Answer: (Not answered)
Correct Answer: B (Ventilating appropriately according to the nature of the cargo, preventing self-heating, harmful gas accumulation or condensation damage)
💡 SOLAS and the IMSBC Code require the method and timing of ventilation to suit the cargo: some need ventilation to remove heat, others must not be ventilated to avoid moisture uptake or increased self-heating. Ventilating blindly may make matters worse.
✗
Question 6. What does SOLAS require as regards the language of certificates?
Your Answer: (Not answered)
Correct Answer: C (They must be drawn up in the official language of the issuing State with a translation into English, French or Spanish)
💡 SOLAS I/5 requires certificates to be in the official language of the issuing State with a translation into English, French or Spanish, so that port States can verify them. A single language alone does not comply.
✗
Question 7. With regard to navigational warnings and notices, which statement is correct?
Your Answer: (Not answered)
Correct Answer: A (The ship must be able to receive them and act on them)
💡 SOLAS V/28: the ship must be able to receive and act on navigational warnings and notices.
✗
Question 8. What is the aggregate capacity requirement for survival craft on a cargo ship?
Your Answer: (Not answered)
Correct Answer: A (The craft on each side must accommodate all persons on board)
💡 SOLAS III/31 requires the survival craft on each side of a cargo ship to accommodate all persons on board, so that everyone can escape whichever side is damaged.
✗
Question 9. What monitoring of cargo temperature and humidity is required?
Your Answer: (Not answered)
Correct Answer: D (Measure and record hold temperature and humidity periodically as the cargo requires, dealing with abnormal heating or condensation promptly)
💡 For cargoes liable to self-heat, heat or sensitive to moisture, such as coal, grain and certain chemicals, the hold temperature and humidity should be measured and recorded periodically, and abnormal temperature rise or condensation investigated, whether from self-heating or incorrect ventilation, with ventilation or other measures taken.
✗
Question 10. The use of the automatic pilot shall be such that:
Your Answer: (Not answered)
Correct Answer: C (in congested waters or restricted visibility the helmsman shall take over hand steering under the direct control of the OOW)
💡 SOLAS V/19: in congested waters or restricted visibility the helmsman shall take over hand steering under the direct control of the OOW.
✗
Question 11. The double bottom shall be fitted:
Your Answer: (Not answered)
Correct Answer: B (extending from the collision bulkhead to the afterpeak bulkhead)
💡 SOLAS II-1/9 requires the double bottom generally to extend from the collision bulkhead to the afterpeak bulkhead.
✗
Question 12. If unable to assist, the master receiving a distress alert shall:
Your Answer: (Not answered)
Correct Answer: D (Endeavour to relay the alert to units able to assist)
💡 Endeavour to relay the alert to units able to render assistance.
✗
Question 13. What is the purpose of the voyage data recorder required by SOLAS V/19?
Your Answer: (Not answered)
Correct Answer: C (To provide data on the navigation and operation of the ship for accident investigation)
💡 The VDR records navigational and operational data for use in casualty investigation. The data is protected and must not be used for crew assessment or other purposes.
✗
Question 14. An additional survey shall be carried out after:
Your Answer: (Not answered)
Correct Answer: D (an accident or a defect affecting safety has been found)
💡 SOLAS I/8: an additional survey shall be carried out after an accident or after a defect affecting safety has been found.
✗
Question 15. For a cargo ship of 2000 GT and above, the auxiliary steering gear shall put the rudder over how quickly?
Your Answer: (Not answered)
Correct Answer: C (From 15° one side to 15° the other in not more than 30 seconds)
💡 SOLAS II-1/29: the auxiliary steering gear shall be capable of putting the rudder over in 30 seconds.
✗
Question 16. When navigating in restricted visibility, what is required for look-out under SOLAS V and COLREG?
Your Answer: (Not answered)
Correct Answer: B (A proper look-out by sight and hearing as well as by radar, with an additional look-out posted forward)
💡 A proper look-out uses sight, hearing and radar together. In restricted visibility an additional look-out should be posted forward and a listening watch maintained. Radar does not replace the human look-out.
✗
Question 17. What do SOLAS and the IMSBC Code address regarding cargo ventilation during a voyage?
Your Answer: (Not answered)
Correct Answer: A (Ventilation should be decided according to the cargo and dew point conditions, avoiding condensation or increased self-heating from incorrect ventilation)
💡 Ventilation should be decided by the nature of the cargo and the dew point. Ventilation is needed to remove heat, but if the outside dew point is higher than in the hold it causes condensation, wetting the cargo and possibly increasing self-heating. Incorrect ventilation can cause cargo damage and danger.
✗
Question 18. The Polar Code (safety measures) applies to:
Your Answer: (Not answered)
Correct Answer: C (ships operating in polar waters, which shall hold a Polar Ship Certificate)
💡 SOLAS XIV/2: the Polar Code applies to ships operating in polar waters, which shall hold a Polar Ship Certificate.
✗
Question 19. Regarding fuel oil in the Antarctic area, which is correct?
Your Answer: (Not answered)
Correct Answer: C (The use and carriage of heavy fuel oil are prohibited)
💡 MARPOL/SOLAS prohibit the use and carriage of heavy fuel oil in the Antarctic area.
✗
Question 20. Steering trials are run at maximum service speed. Under SOLAS II-1/29, within what time must the main steering gear put the rudder over from 35 degrees on one side to 30 degrees on the other?
Your Answer: (Not answered)
Correct Answer: D (Not more than 28 seconds)
💡 SOLAS II-1/29 requires the main steering gear, at deepest seagoing draught and maximum service speed, to put the rudder over from 35 degrees to 30 degrees within 28 seconds. The 60-second limit applies to the auxiliary steering gear for 15 degrees to 15 degrees.
✗
Question 21. What is the risk if a crew member answers vaguely when asked about equipment operation?
Your Answer: (Not answered)
Correct Answer: D (It raises doubt about training and the effective operation of the system and may lead to a deeper inspection)
💡 A vague answer about equipment or emergency duties indicates that training and familiarisation may not be effective. The inspector will go deeper, including asking for practical demonstrations and checking records, and may find that the system is not effectively implemented.
✗
Question 22. What is the role of the bulkhead deck in subdivision?
Your Answer: (Not answered)
Correct Answer: A (It is the deck to which the main watertight bulkheads extend upward from the bottom)
💡 The bulkhead deck is the uppermost deck to which the main watertight bulkheads extend, forming the basis for subdivision and damage stability calculations.
✗
Question 23. What marking shall survival craft have for night detection?
Your Answer: (Not answered)
Correct Answer: D (Lighting or retro-reflective material to aid detection)
💡 Lighting or retro-reflective material to aid detection.
✗
Question 24. What is the basic requirement of a proper look-out during a navigational watch?
Your Answer: (Not answered)
Correct Answer: A (Maintain look-out by sight and hearing as well as by all available means, with the look-out not impeded by other duties)
💡 COLREG and SOLAS require a look-out at all times by sight, hearing and all available means, making a full appraisal of the situation and risk of collision. The look-out must not be given duties that interfere with the watch.
✗
Question 25. Besides the number, what has to be managed about portable extinguishers?
Your Answer: (Not answered)
Correct Answer: B (placed where they are seen and reached at once, their agent marked on them, and tested at the intervals set)
💡 Beyond the count there are three things to hold. Where they stand: well distributed, plainly seen, not behind cargo or equipment, one near the entrances to a machinery space and about the accommodation, so the plate and the escape lighting let a man find one through smoke. What is in them: matched to the fire the space can give - water not being the thing for a liquid fire or a live circuit - with the agent stated on the set so nobody grabs the wrong one. And their condition: weighed, gauged and checked at the intervals fixed, sent away or scrapped when the date or the pressure says so, the check and its finding written down. The number is settled for the type of space and this ship's layout, not copied from another vessel, and the crew are trained to draw and use them under strain, knowing both the reach and the short time each will serve.
✗
Question 26. What does SOLAS require regarding the arrangement of scuppers, inlets and discharges on a ship's sides?
Your Answer: (Not answered)
Correct Answer: C (They must not lead water into spaces where it would be dangerous, and reliable means of closure must be fitted)
💡 SOLAS II-1 regulates the arrangement and closing appliances of overboard scuppers and inlets so that water cannot enter spaces where it would create a hazard through damage or inadvertent operation.
✗
Question 27. What should be done if a ship receives another's distress alert but cannot herself assist directly?
Your Answer: (Not answered)
Correct Answer: A (Relay the alert and reply promptly, explaining the situation and informing a coast station or rescue service if necessary)
💡 GMDSS procedure requires a ship receiving another's distress alert to reply promptly and explain the situation, such as her distance, capability and whether she can proceed, and to relay the alert to a coast station or rescue service. No response or ignoring it is not acceptable.
✗
Question 28. What should be done about items not covered by life-saving appliance inspections?
Your Answer: (Not answered)
Correct Answer: B (Explain the reason and give them priority in subsequent inspections; they must not be left unchecked for long)
💡 Life-saving appliances left uninspected for a long period require the reason to be established, such as an omission or a change of personnel, and the inspection to be scheduled as a priority, with the records reflecting the actual condition. Long neglect leaves their condition unknown and they may be unusable in an emergency.
✗
Question 29. Muster and embarkation stations shall be located so that:
Your Answer: (Not answered)
Correct Answer: D (persons can proceed conveniently to the embarkation position or via a stairway)
💡 SOLAS III/11 requires muster and embarkation stations to be conveniently accessible for boarding survival craft.
✗
Question 30. Where shall manual fire alarm call points be located?
Your Answer: (Not answered)
Correct Answer: A (In corridors and near exits where persons can reach them)
💡 They are located in corridors and near exits for easy access.
✗
Question 31. Extension of a certificate is permitted:
Your Answer: (Not answered)
Correct Answer: B (only in special circumstances when the ship is not in a port of survey, as authorized by the Administration)
💡 SOLAS I/14: extension of a certificate is permitted only in special circumstances when the ship is not in a port of survey.
✗
Question 32. What is required when anchoring in restricted visibility?
Your Answer: (Not answered)
Correct Answer: A (Choose a position after confirming suitable depth and bottom and the absence of dangers nearby, keeping radar and visual monitoring afterwards)
💡 If anchoring becomes necessary in poor visibility, the depth and nature of the bottom and the surrounding area should first be confirmed. After anchoring, radar and visual watch should be maintained, dragging monitored, the anchor lights and shapes displayed and engines kept ready.
✗
Question 33. What should be done about a failed water ingress detector on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (Repair promptly and, pending repair, increase manual checks such as sounding the bilges, with records kept)
💡 A failed water ingress detector should be repaired as soon as possible and, pending repair, manual checks increased, such as periodic sounding of holds, ballast tanks and bilges, with the failure and the temporary measures recorded. Switching the system off would remove the warning of flooding and is a serious deficiency.
✗
Question 34. What must the VDR record?
Your Answer: (Not answered)
Correct Answer: B (Position, course, speed, radar images, bridge audio and alarms)
💡 SOLAS requires the VDR to record data relevant to investigation, including date and time, position, course, speed, radar images with AIS, bridge audio, alarms and rudder orders, enabling the navigation and operation at the time to be reconstructed.
✗
Question 35. What operational limitations must the PWOM contain?
Your Answer: (Not answered)
Correct Answer: A (The ice conditions and temperature range in which the ship may operate and the action to take if limits are exceeded)
💡 The PWOM must state the ship's operational capabilities and limitations in polar waters, including the ice conditions and temperature range in which she may operate, the limitations of equipment and the action to take if the limits are exceeded, enabling the master to decide correctly in ice.
✗
Question 36. How many rocket parachute flares must each survival craft carry?
Your Answer: (Not answered)
Correct Answer: A (4)
💡 SOLAS III/7.1 requires four rocket parachute flares in each survival craft. Six is the usual number for hand flares, which is easily confused with this.
✗
Question 37. How must records of servicing and inspection of life-saving appliances be handled under SOLAS III?
Your Answer: (Not answered)
Correct Answer: B (They must be kept on board and produced at statutory surveys)
💡 SOLAS III requires records of inspections and maintenance of life-saving appliances to be kept on board for verification at statutory and PSC inspections. Company-only records or oral reports are not sufficient.
✗
Question 38. What is the general requirement for the location of embarkation stations?
Your Answer: (Not answered)
Correct Answer: A (Where persons can board safely, as far as practicable from the propulsion plant and dangerous goods)
💡 SOLAS requires embarkation stations to be located where persons can board safely, taking account of the need to be clear of propellers, thrusters, exhausts and dangerous goods, so that persons are not injured while boarding and the operation is possible even if the ship still has headway.
✗
Question 39. What is the precondition for using a loading instrument on board?
Your Answer: (Not answered)
Correct Answer: D (It must be approved by the Administration or a recognised organisation, agree with the ship and be periodically verified)
💡 SOLAS requires the loading instrument used on board to be approved by the Administration or a recognised organisation, with its program consistent with the actual ship data and periodically verified. Unapproved software may not be used for stability calculations.
✗
Question 40. Before hot work in the cargo tank area of a tanker, what must be done under SOLAS and related guidance?
Your Answer: (Not answered)
Correct Answer: D (Gas testing, a hot work permit, removal of combustibles and firefighting standby precautions)
💡 SOLAS and ISGOTT require gas testing, removal of combustible material, a hot work permit and firefighting standby before hot work in a tanker's cargo area. None of these steps may be omitted.
✗
Question 41. An inflatable liferaft shall:
Your Answer: (Not answered)
Correct Answer: B (inflate automatically when launched and also be capable of manual inflation)
💡 SOLAS III/36 (LSA Code) requires an inflatable liferaft to inflate automatically when launched, with manual inflation also provided.
✗
Question 42. Which systems shall be used to receive navigational warnings?
Your Answer: (Not answered)
Correct Answer: C (Maritime safety information systems such as NAVTEX and SafetyNET)
💡 Systems such as NAVTEX and SafetyNET.
✗
Question 43. Which of the following is the "Company" the ISM Code means?
Your Answer: (Not answered)
Correct Answer: A (the owner of the ship, or any other organisation or person who has taken on the responsibility for operating it and agreed to take over the obligations the rules impose)
💡 The definition rests on two conditions: having taken the responsibility for operating the ship from the owner, and having agreed to take on the duties and liability the rules lay out. Whoever meets them may be the owner, a manager or a bareboat charterer, so a management agreement does not of itself leave the position with the registered owner; and a supplier who does routine maintenance or finds crew alone does not become it by that. The one recognised as the Company is the one to whom the document of compliance is issued, the party named in the safety management certificate must match, and the agreement between them should mark out responsibility, authority and resources so that no gap opens where neither side answers. What the owner owes in respect of the ship does not disappear with the delegation, yet the running of the system sits with whoever carries the operating responsibility. The organisation that issues the certificate is the administration or one recognised by it, and is not the Company as defined.
✗
Question 44. How must a ship fulfil the duty to render assistance at sea under SOLAS V?
Your Answer: (Not answered)
Correct Answer: A (To proceed with all speed to render assistance where there is reasonable ground to believe another ship is in distress, and to inform the owner or agent)
💡 SOLAS requires the master to proceed with all speed to render assistance where there is reasonable ground to believe a ship is in distress, and to inform the owner or agent. Assistance is a legal duty.
✗
Question 45. On what basis may the Administration issue an exempted certificate?
Your Answer: (Not answered)
Correct Answer: A (Where the ship's particular voyage makes compliance unreasonable, provided the conditions are safe and consistent with the purpose of the Convention)
💡 SOLAS I/12 permits an exemption where the ship is not engaged on an international voyage and the circumstances of the voyage make compliance unreasonable or unnecessary, provided safety is assured.
✗
Question 46. What material shall be used for fuel oil piping and fittings?
Your Answer: (Not answered)
Correct Answer: B (Steel or other approved material, securely connected)
💡 Steel or approved material with secure connections shall be used.
✗
Question 47. What special life-saving appliance requirements apply in polar waters?
Your Answer: (Not answered)
Correct Answer: D (Measures to extend survival time, such as collective survival craft, thermal protection and search aids)
💡 The Polar Code requires life-saving appliances to address the need to extend survival time in polar regions, including collective survival craft of adequate capacity and thermal performance, ample thermal protective aids and equipment aiding detection by rescuers, such as radar reflectors, SARTs and locating devices, together with corresponding emergency supplies.
✗
Question 48. What length must a rescue boat have under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Not less than 3.8 m and not more than 8.5 m)
💡 SOLAS requires a rescue boat to be not less than 3.8 m and not more than 8.5 m in length, balancing carrying capability against the ability to be manoeuvred and recovered quickly. Too small gives insufficient capacity, too large hinders rapid handling.
✗
Question 49. When peak and deep tanks are used as ballast tanks, what does SOLAS II-1 require of the ballast system?
Your Answer: (Not answered)
Correct Answer: B (It must be capable of safely filling and emptying ballast tanks under all operating conditions)
💡 SOLAS II-1 requires the ballast system to fill and empty tanks safely under all operating conditions so that draught and stability can be controlled. It is not confined to port use.
✗
Question 50. What is the correct principle for action taken to avoid collision?
Your Answer: (Not answered)
Correct Answer: A (It should be taken in ample time, be large enough and be readily apparent to the other vessel)
💡 Under the collision regulations action to avoid collision should be taken in ample time and should be large enough and readily apparent to the other vessel by sight or radar, with reduction of speed or stopping where necessary. Insufficient or hesitant action is an important cause of close-quarters situations.
✗
Question 51. What is the significance of the marine pollutant mark required by the IMDG Code?
Your Answer: (Not answered)
Correct Answer: A (It identifies a cargo harmful to the environment, requiring stricter pollution prevention measures if it leaks)
💡 The IMDG Code requires the marine pollutant mark on goods meeting the criteria, identifying a cargo that would harm the environment if released. Stricter pollution prevention and response requirements apply to a spill, with reporting as prescribed.
✗
Question 52. What is required regarding medication affecting the ability to keep watch?
Your Answer: (Not answered)
Correct Answer: A (Crew taking medication that may impair judgement or reaction must not keep watch, with the company managing the risk)
💡 Medication that may cause drowsiness, reduced attention or slow reactions, such as some cold remedies, sedatives and antihistamines, impairs the ability to keep watch. Crew should report it and avoid standing watch or be relieved, and the company should have management requirements and a means for seafarers to declare their condition.
✗
Question 53. On discovering equipment that may endanger safety, the master shall:
Your Answer: (Not answered)
Correct Answer: A (Take immediate precautions and, if necessary, report and seek assistance)
💡 Take immediate precautions and, if needed, report and seek assistance.
✗
Question 54. What is the requirement for lights carried in survival craft?
Your Answer: (Not answered)
Correct Answer: B (They must indicate the position of the craft in darkness, with self-igniting lights or torches as prescribed)
💡 SOLAS requires survival craft to carry means of indicating their position in darkness, including a self-igniting light or an approved electric torch, so that they can be found at night.
✗
Question 55. For how long shall a VDR retain its recorded data as a minimum?
Your Answer: (Not answered)
Correct Answer: B (12 hours)
💡 SOLAS V/20: the VDR shall retain at least the last 12 hours of data.
✗
Question 56. A PSC inspection found the annual survey endorsement on a certificate three months overdue while the ship continued trading. What is the basis for action?
Your Answer: (Not answered)
Correct Answer: B (Certificates must be endorsed after annual surveys as required; an overdue survey makes the certificate invalid)
💡 SOLAS I/10 requires certificates to be endorsed after annual surveys within the validity period. Where the endorsement is overdue the certificate is no longer valid, and continued trading is a serious deficiency on which the port State may detain the ship.
✗
Question 57. What maintenance is required for steering gear hydraulic oil and filters?
Your Answer: (Not answered)
Correct Answer: B (Oil quality checked, filters and oil changed as the manufacturer requires, with maintenance recorded)
💡 The hydraulic steering gear should have its oil quality checked periodically, including water, contamination and viscosity changes, with filters and oil changed as the maker requires and the maintenance recorded. Deteriorated oil causes valves to stick and steering to fail, so this is preventive maintenance of essential equipment.
✗
Question 58. What should be done if the loading instrument of a bulk carrier computes abnormally?
Your Answer: (Not answered)
Correct Answer: D (Stop relying on it and use an approved manual method or shore support, repairing and verifying it as soon as possible)
💡 If a loading instrument computes abnormally, such as results clearly differing from hand calculation or the program reporting errors, reliance on it should cease and an approved manual method or shore support used to complete the strength and stability checks, with the instrument repaired and verified as soon as possible, preventing a wrong result from causing overloading or structural damage.
✗
Question 59. What does the Polar Code address regarding safety equipment for ships in polar waters?
Your Answer: (Not answered)
Correct Answer: B (Equipment suited to the polar environment for life-saving, firefighting, ice protection and emergencies)
💡 The Polar Code requires equipment suited to the polar environment, such as thermally protective life-saving appliances, firefighting equipment suitable for low temperature, ice protection and de-icing arrangements and emergency communication and escape means. Ordinary water equipment is not sufficient.
✗
Question 60. What does SOLAS require regarding a look-out when the ship is under way?
Your Answer: (Not answered)
Correct Answer: A (A look-out must be posted when conditions require it, to assist the officer in maintaining a proper look-out)
💡 SOLAS and COLREG require a look-out to be posted when conditions demand it, such as in restricted visibility, dense traffic or narrow channels. The look-out's sole duty is to keep watch and report, without other tasks such as steering.
✗
Question 61. The general emergency alarm shall be audible:
Your Answer: (Not answered)
Correct Answer: B (Throughout the ship, including crew accommodation)
💡 Throughout the ship, including crew accommodation.
✗
Question 62. A paint locker shall be located behind:
Your Answer: (Not answered)
Correct Answer: B (A class divisions, with independent ventilation and extinguishing arrangements)
💡 SOLAS II-2/9 requires paint lockers to be bounded by A class divisions with independent ventilation and extinguishing.
✗
Question 63. What does 'Company' mean in SOLAS?
Your Answer: (Not answered)
Correct Answer: A (The shipowner or an organization which has assumed responsibility for operation)
💡 It means the owner or any organization which has assumed responsibility for the ship's operation.
✗
Question 64. What must the watertight door indicator on the bridge show?
Your Answer: (Not answered)
Correct Answer: B (The open or closed status of each watertight door, with its position corresponding to the ship's arrangement)
💡 SOLAS requires the indicator on the bridge to show the open or closed status of each watertight door with its position identified to correspond with the ship's arrangement, so the watchkeeper knows exactly which door is open.
✗
Question 65. Which system, directly related to fire protection, is required in accommodation and service spaces?
Your Answer: (Not answered)
Correct Answer: B (Fixed fire detection and alarm system)
💡 SOLAS II-2/12 requires fixed fire detection and alarm systems in accommodation and service spaces.
✗
Question 66. What are the handling requirements when encountering heavy swell and seas?
Your Answer: (Not answered)
Correct Answer: A (Adjust course and speed so that the hull meets the seas at a suitable angle, avoiding a beam sea and direct head seas which cause damage)
💡 In heavy seas and swell the course and speed should be adjusted so the hull meets the seas at a suitable angle, normally obliquely, avoiding a beam sea which causes heavy rolling and cargo shift and direct head seas which cause violent pitching and slamming that damages the hull.
✗
Question 67. What is the core requirement of SOLAS II-2/4.5.9 for the arrangement of fuel oil, lubricating oil and other flammable oils?
Your Answer: (Not answered)
Correct Answer: A (They shall be kept clear of hot surfaces and arranged and protected to prevent ignition)
💡 SOLAS II-2 requires flammable oils to be kept away from hot surfaces and protected against spraying onto sources of ignition.
✗
Question 68. Under the ISPS Code, which security officer must be designated on board?
Your Answer: (Not answered)
Correct Answer: C (Ship Security Officer)
💡 ISPS Code A/11 requires a Ship Security Officer to be designated on board.
✗
Question 69. What is required for monitoring stability during loading and unloading?
Your Answer: (Not answered)
Correct Answer: C (Monitor stability and strength at each stage against the loading plan, preventing excessive hogging or sagging or insufficient initial stability)
💡 SOLAS requires stability and hull strength to be monitored at each stage against the loading plan, preventing excessive hogging or sagging and insufficient initial stability. Calculating only afterwards cannot prevent structural damage during cargo work.
✗
Question 70. What items does the stability assessment after loading include?
Your Answer: (Not answered)
Correct Answer: D (Initial metacentric height, the righting lever curve, the maximum righting lever and the weather criterion)
💡 Intact stability assessment normally includes the initial metacentric height, the shape and range of the righting lever curve, the maximum righting lever and its angle and the weather criterion, the ratio of heeling to righting moment. Calculating the initial metacentric height alone does not ensure intact stability.
✗
Question 71. What does a B-15 class division mean?
Your Answer: (Not answered)
Correct Answer: D (It prevents the passage of flame and limits temperature rise for 15 minutes in the standard fire test)
💡 Class B divisions are graded B-15 and B-0, the figure being the period in minutes for which temperature rise is limited in the standard fire test. Class B divisions are of non-combustible material, preventing passage of flame with lower strength than class A.
✗
Question 72. What fire detection is required in spaces carrying dangerous goods?
Your Answer: (Not answered)
Correct Answer: C (Detection suited to the cargo, with gas detection for certain cargoes)
💡 SOLAS and the IMDG Code require spaces carrying dangerous goods to have detection suited to the cargo, such as smoke, heat or gas detection, with gas detection and alarm where flammable gas may be released, so that an incipient fire or a leak is detected promptly.
✗
Question 73. What does SOLAS require for electrical equipment used in hazardous areas of machinery spaces?
Your Answer: (Not answered)
Correct Answer: C (It must be of a type protected against the hazard appropriate to that area)
💡 SOLAS II-1 requires electrical equipment in machinery spaces and other hazardous areas to be of a type protected against the particular hazard, so as to prevent ignition.
✗
Question 74. Which certificate shall a ship hold under the ISPS Code?
Your Answer: (Not answered)
Correct Answer: A (ISSC)
💡 The International Ship Security Certificate.
✗
Question 75. Lifeboat launching drills shall be conducted:
Your Answer: (Not answered)
Correct Answer: B (under sailing conditions as well, to train the crew in emergency operations)
💡 SOLAS III/19: lifeboat launching drills shall be conducted under sailing conditions as well, so as to train the crew in actual operation.
✗
Question 76. The deck foam system of a tanker shall be capable of supplying foam over the protected deck area within:
Your Answer: (Not answered)
Correct Answer: A (30 minutes)
💡 SOLAS II-2/20: the deck foam system shall be capable of supplying foam over the protected deck area within 30 minutes.
✗
Question 77. What should be checked about the type approval marking of life-saving appliances?
Your Answer: (Not answered)
Correct Answer: C (That the appliance bears the approval marking or certificate number of the Administration or a recognised body)
💡 SOLAS and the LSA Code require life-saving appliances to be type approved and to bear the approval marking or certificate number. On inspection the marking should be clear and consistent with the certificate. Appliances without an approval mark may not be accepted by the surveyor or the PSC, and are a deficiency.
✗
Question 78. What does SOLAS address regarding arrangements to contain leakage from oil systems?
Your Answer: (Not answered)
Correct Answer: A (Measures to collect leaking oil, preventing it from reaching the bilges or hot surfaces)
💡 SOLAS requires measures to collect leakage from lubricating and hydraulic oil systems, such as drip trays and cofferdams, preventing oil from accumulating in the bilges or contacting hot surfaces when pumped, which could cause fire, and reducing pollution.
✗
Question 79. What is the required capacity of the main source of electrical power?
Your Answer: (Not answered)
Correct Answer: D (It must be capable of supplying all services necessary to maintain the ship in normal operational and habitable conditions)
💡 SOLAS II-1/40 requires the main source to supply all services necessary for normal operation and habitability, including propulsion auxiliaries, lighting, ventilation and communications.
✗
Question 80. Speed and distance measuring equipment shall provide the bridge with:
Your Answer: (Not answered)
Correct Answer: C (speed and distance information over the ground)
💡 SOLAS V/19 requires speed and distance measuring equipment providing speed and distance over the ground.
✗
Question 81. Regarding ventilation of cargo tank areas on a tanker:
Your Answer: (Not answered)
Correct Answer: D (adequate ventilation shall be provided with inlets and outlets arranged to prevent accumulation of vapour)
💡 SOLAS II-2/4 requires adequate ventilation arranged to prevent accumulation of vapour.
✗
Question 82. When inerting the cargo tanks of a tanker, what is the usual upper limit for the oxygen content of the tank atmosphere?
Your Answer: (Not answered)
Correct Answer: A (Not more than five per cent by volume)
💡 Under SOLAS II-2/4 and the related requirements, when the cargo tanks of a tanker are inerted the oxygen content of the tank atmosphere should be held below five per cent by volume so that a flammable mixture cannot form. The inert gas system should maintain a positive tank pressure and monitor the oxygen content, and the operation should stop if the limit is exceeded.
✗
Question 83. In an overtaking situation, how are responsibility and duties allocated?
Your Answer: (Not answered)
Correct Answer: C (The overtaking vessel must keep out of the way and the overtaken vessel keeps her course and speed)
💡 Under the collision regulations the overtaking vessel must keep out of the way of the vessel being overtaken in all situations until finally past and clear, while the overtaken vessel keeps her course and speed. A vessel approaching from more than twenty-two point five degrees abaft the beam of the vessel ahead is overtaking.
✗
Question 84. How should a lifeboat be launched?
Your Answer: (Not answered)
Correct Answer: D (Controlled from within the boat (gravity davit) with the lowering speed controlled and the boat kept steady)
💡 A lifeboat is launched under control from within the boat, with a release arrangement in the boat for a gravity davit. The lowering speed should be controlled, contact with the ship's side prevented and the boat turned and cleared for release before entering the water. Too fast a descent causes casualties and structural damage.
✗
Question 85. On passenger ships, the width of means of escape shall:
Your Answer: (Not answered)
Correct Answer: A (meet the prescribed requirements for the number of persons to be evacuated)
💡 SOLAS II-2/13 requires escape routes and stairways to have the width prescribed for the number of persons.
✗
Question 86. What testing do fire pumps require in port?
Your Answer: (Not answered)
Correct Answer: A (Periodic testing of starting, discharge and pressure with records kept)
💡 SOLAS and good practice require periodic testing of fire pumps, including the method of starting, the discharge and whether the pressure meets the requirement, with the results recorded, keeping the system serviceable. Long neglect means a pump may not start when actually needed.
✗
Question 87. What is the relationship between lifejackets and immersion suits in survival craft?
Your Answer: (Not answered)
Correct Answer: A (A lifejacket provides buoyancy while an immersion suit provides thermal protection and buoyancy; they have different functions)
💡 A lifejacket principally provides buoyancy and a face-up attitude in the water, while an immersion suit provides both thermal protection and buoyancy. Their functions differ. In cold waters the ship should carry immersion suits while lifejackets remain required for every person; the two are used together.
✗
Question 88. The isolating valve on the fire main serving the accommodation side has long been seized and cannot be operated. How should this be judged?
Your Answer: (Not answered)
Correct Answer: D (Fire main isolating valves must be operable at all times; being seized is a deficiency affecting the isolating function)
💡 Isolating valves on the fire main are used to isolate a damaged section of piping so that the rest of the system still receives water. They must be capable of manual operation at all times. Being seized deprives them of their isolating function and is a deficiency affecting the reliability of the firefighting system, which should be rectified.
✗
Question 89. Which MF frequency is used for DSC distress alerting?
Your Answer: (Not answered)
Correct Answer: A (2187.5 kHz)
💡 The MF DSC distress frequency is 2187.5 kHz. 2182 kHz is the MF radiotelephony distress frequency and 2174.5 kHz is used for NBDP distress traffic.
✗
Question 90. The watertight door indicator showed a door open while it was in fact closed. What is the finding?
Your Answer: (Not answered)
Correct Answer: B (A deficiency; the indicator must accurately reflect the actual status, as a false indication misleads the assessment of watertight integrity)
💡 The watertight door indicator on the bridge must accurately reflect the actual open or closed status. A false indication would lead the watchkeeper to a wrong appreciation of watertight integrity and to incorrect measures after damage, so it is a deficiency affecting safety.
✗
Question 91. What does SOLAS require for the power or drive of the emergency fire pump?
Your Answer: (Not answered)
Correct Answer: D (It must be independently driven with a power or fuel supply unaffected by a fire in the machinery space)
💡 SOLAS requires the emergency fire pump to be independently driven, with its source of power or fuel arranged so that a fire in the machinery space does not put it out of action.
✗
Question 92. What should be done when a detection system alarms without an actual fire?
Your Answer: (Not answered)
Correct Answer: C (Establish the cause, such as a contaminated detector, a fault or a real latent hazard, and deal with it before resetting)
💡 When the cause of an alarm is unclear, it should be established whether a detector is contaminated, there is a circuit fault or a real latent hazard exists, such as concealed smouldering, and dealt with before resetting. Simply resetting or disabling the circuit conceals a real danger, a serious concern.
✗
Question 93. What is the interval for the load test of lifeboat launching appliances under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (Not more than five years, tested at the rated complement or prescribed load)
💡 SOLAS III/35 requires launching appliances to be tested at intervals of not more than five years with the prescribed load, including the rated complement or an equivalent load, verifying actual performance and safety.
✗
Question 94. What layers of protection do SOLAS and the IMO resolutions require for enclosed space entry?
Your Answer: (Not answered)
Correct Answer: B (Ventilation, testing, a permit, a standby person and rescue preparation forming a complete entry procedure)
💡 SOLAS and the IMO resolutions require a complete procedure for enclosed space entry: ventilation, testing, a permit, a standby person and rescue arrangements. The layers work together; no single measure ensures safety.
✗
Question 95. If a fire drill cannot be held in a month due to bad weather, what does SOLAS require?
Your Answer: (Not answered)
Correct Answer: A (Hold it as soon as conditions permit and record the reason in the deck log)
💡 SOLAS requires a drill not held in the scheduled month to be held as soon as conditions permit, normally within 24 hours afterwards, with the reason for the delay recorded in the deck log.
✗
Question 96. What is required for closing appliances on overboard discharges below the load line?
Your Answer: (Not answered)
Correct Answer: B (Effective closing appliances operable from above the bulkhead deck, preventing back flooding)
💡 SOLAS and the Load Line Convention require discharges and inlets below the load line to have effective closing appliances such as non-return valves or cocks, operable from above the bulkhead deck, preventing sea water from entering. Temporary plugs of wood are not reliable.
✗
Question 97. What are the limitations on the use of the automatic pilot?
Your Answer: (Not answered)
Correct Answer: B (Hand steering must be resumed in restricted visibility, dense traffic, narrow channels or when frequent manoeuvring is required)
💡 STCW and SOLAS require hand steering to be resumed in restricted visibility, dense traffic, narrow channels or when frequent manoeuvring is needed on ships using an automatic pilot. The autopilot does not reduce the number of look-outs required and the officer must be ready to steer by hand at any time.
✗
Question 98. What does SOLAS address regarding the combustibility of curtains and decorative materials in accommodation?
Your Answer: (Not answered)
Correct Answer: D (Their combustibility must be restricted, using flame retardant or treated materials)
💡 SOLAS places requirements on the combustibility of curtains, carpets and decorative materials in accommodation spaces, requiring flame retardant or treated materials to prevent fire from spreading rapidly along them.
✗
Question 99. What does SOLAS chapter II-2 require of the layout of fire mains and hydrants?
Your Answer: (Not answered)
Correct Answer: D (at least two jets reaching any part of the space protected, one of them on a single length of hose, with the specified fire pumps working)
💡 The chapter fixes the number of jets and the pressure by ship type: cargo ships as a rule require at least two jets from different hydrants, one of them available on a single length of hose to any part of the space protected, with separate requirements for machinery spaces. Main diameter, pump capacity and nozzle size have to match, or the far hydrant loses pressure. Layout follows coverage and simultaneous use, not ease of maintenance or a ratio of floor area, which tells nothing about jets.
✗
Question 100. What shall the Continuous Synopsis Record contain?
Your Answer: (Not answered)
Correct Answer: D (The history and major particulars of the ship)
💡 The history and major particulars of the ship.