Question 1. What does SOLAS address regarding protection of hot surfaces in machinery spaces?
Your Answer: (Not answered)
Correct Answer: D (Surfaces above the prescribed temperature must be insulated or guarded, preventing ignition of oil on contact)
💡 SOLAS requires piping and equipment surfaces above the prescribed temperature, such as 220 degrees Celsius, to be insulated or guarded, preventing fuel or lubricating oil from being ignited on contact.
✗
Question 2. In what circumstances must an immersion suit be provided for every person on board?
Your Answer: (Not answered)
Correct Answer: D (When the ship operates in cold waters and the thermal protection provided by the survival craft is otherwise insufficient)
💡 SOLAS III/32 requires an immersion suit for every person on board when the ship operates in cold waters and the survival craft do not provide sufficient thermal protection. It is not a universal requirement in all trades.
✗
Question 3. What shall the Continuous Synopsis Record contain?
Your Answer: (Not answered)
Correct Answer: D (The history and major particulars of the ship)
💡 The history and major particulars of the ship.
✗
Question 4. What are the operating requirements for a lifejacket light?
Your Answer: (Not answered)
Correct Answer: A (It must operate automatically and last at least the prescribed period, normally eight hours or more)
💡 The light fitted to a lifejacket must operate automatically in water and last for at least the prescribed period, normally eight hours, so that persons can be seen at night. Manual operation or an ordinary torch is not acceptable.
✗
Question 5. What do SOLAS and good practice address regarding life-saving appliances during temporary repairs?
Your Answer: (Not answered)
Correct Answer: D (Life-saving appliances must remain available; if affected, compensating measures must be taken and accepted by the Administration)
💡 If life-saving appliances must be temporarily removed or are affected during repairs, compensating measures such as adjusting the arrangement, limiting the number of persons or restricting the area of work must be taken and accepted by the Administration or the classification society. The ship must not sail with the deficiency unaddressed.
✗
Question 6. The deck foam system of a tanker shall be capable of supplying foam over the protected deck area within:
Your Answer: (Not answered)
Correct Answer: A (30 minutes)
💡 SOLAS II-2/20: the deck foam system shall be capable of supplying foam over the protected deck area within 30 minutes.
✗
Question 7. What do SOLAS and good practice address regarding watertight doors kept open while in port?
Your Answer: (Not answered)
Correct Answer: A (They may be opened as required for operations, but must remain capable of immediate closing with attention to changes in the ship's condition)
💡 Some watertight doors may be opened in port for cargo work or access, but must remain capable of being closed at once, with their status indicated on the bridge, and must be closed again if the ship's condition changes, such as draught change during cargo work, preventing inadvertent flooding.
✗
Question 8. The sewage treatment plant is found not in operation and untreated sewage is being discharged directly. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Discharging untreated sewage does not meet the rules, a pollution prevention deficiency)
💡 Discharge of sewage must meet the applicable rules, that is, be treated by an approved treatment plant and meet the discharge conditions, or be discharged as permitted beyond the specified distance. Direct discharge of untreated sewage with the plant not running does not meet pollution prevention requirements and is a deficiency to be corrected.
✗
Question 9. The voyage plan shall include:
Your Answer: (Not answered)
Correct Answer: A (a berth-to-berth plan giving due consideration to navigational hazards including safe speed)
💡 SOLAS V/34: the voyage plan covers the whole passage from berth to berth, giving due consideration to navigational hazards and safe speed.
✗
Question 10. From what source must radio equipment be supplied when the main source of power fails?
Your Answer: (Not answered)
Correct Answer: D (From the emergency source or a dedicated reserve source, maintaining distress communication capability)
💡 SOLAS IV/9 requires radio equipment to be supplied from the emergency source or a dedicated reserve source for at least one hour, so that distress alerting capability is not lost.
✗
Question 11. A steering gear compartment shall be provided with communication facilities:
Your Answer: (Not answered)
Correct Answer: B (two-way communication between the navigation bridge and the steering gear compartment)
💡 SOLAS II-1/29 requires two-way communication between the navigation bridge and the steering gear compartment.
✗
Question 12. What does SOLAS require regarding manoeuvring information?
Your Answer: (Not answered)
Correct Answer: C (Manoeuvring information such as turning circles and stopping distances must be available on board for the master's use)
💡 SOLAS V/19.2.8 requires manoeuvring information such as turning circles, stopping distances and track reach to be on board for the master's use in narrow channels and during berthing. Shore-side retention does not comply.
✗
Question 13. How shall watertight doors be operable locally?
Your Answer: (Not answered)
Correct Answer: B (By two persons, one from each side)
💡 They shall be operable locally by two persons, one from each side.
✗
Question 14. How must new regulations and circulars be implemented?
Your Answer: (Not answered)
Correct Answer: D (Obtain and assess their effect on the ship promptly, implement the measures and train the crew)
💡 The ISM system requires the ship to obtain new regulations, flag State notices and company circulars promptly, assess their actual effect on the ship, covering equipment, procedures, training and records, implement the necessary measures and brief and train the crew, keeping the ship in compliance with the latest requirements.
✗
Question 15. What does SOLAS address regarding furniture and mattresses in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: A (Materials must restrict fire spread and reduce the production of toxic smoke)
💡 SOLAS requires furniture and mattresses in accommodation to be limited in combustibility and in the toxicity of the smoke produced, reducing the risk of death or injury from smoke inhalation in a fire, as part of the protection of persons.
✗
Question 16. How does a pilot on board affect the master's responsibility?
Your Answer: (Not answered)
Correct Answer: C (The presence of a pilot does not relieve the master or officers)
💡 The presence of a pilot does not relieve the master or officers of responsibility.
✗
Question 17. An escape route in the engine room is found permanently blocked by stores. The finding is?
Your Answer: (Not answered)
Correct Answer: C (Escape routes must be kept clear; blockage seriously affects emergency evacuation, a serious deficiency)
💡 A machinery space should have two escape routes as widely separated as practicable, always available. A blocked escape route endangers the evacuation of engine room personnel in a fire or other emergency. It is a serious deficiency affecting personnel safety and the obstruction should be removed at once.
✗
Question 18. What are the key points in operating the deck foam system of a tanker?
Your Answer: (Not answered)
Correct Answer: A (It must cover the whole cargo tank deck, with the foam applied to blanket the burning surface and smother the fire)
💡 The deck foam system must be capable of covering the whole cargo tank deck area, with the foam applied so as to blanket the burning surface and exclude air, avoiding disturbance of the foam layer. Directing it only at the centre of the flames or applying incomplete coverage allows the fire to reignite.
✗
Question 19. What do SOLAS and good practice address regarding the arrangement of GMDSS antennas?
Your Answer: (Not answered)
Correct Answer: C (Arranged so that equipment does not interfere with one another and essential communication capability remains if damage occurs)
💡 SOLAS and good practice require GMDSS antennas to be arranged to avoid interference between transmitting antennas and to retain back-up capability if the main antenna is damaged. Grouping them together means one failure disables all.
✗
Question 20. After flooding on one side, the Master of a passenger ship must assess surviving capability. What information does SOLAS require on board, and how is it used?
Your Answer: (Not answered)
Correct Answer: D (the damage control plan and damage-stability information, marking the openings and valves to be closed and their locations, each confirmed and reported back to the bridge)
💡 Intact and damaged stability are separate assessments: the general arrangement plan and loading manual cover normal conditions, surviving capability after flooding comes from the damage-stability information, and openings, scuppers and valves must be closed item by item against the damage control plan with confirmation back to the bridge. Complete information with nobody executing it recurs in casualty reports.
✗
Question 21. What measures must be taken when shipping a bulk cargo which may release toxic or flammable gas?
Your Answer: (Not answered)
Correct Answer: B (Increased ventilation, gas testing and restriction of entry into the holds as necessary)
💡 The IMSBC Code and SOLAS require increased ventilation and gas testing for cargoes that may release toxic or flammable gas, and gas testing with an entry permit before anyone enters a hold, preventing poisoning and explosion.
✗
Question 22. What must the emergency fire pump satisfy in respect of capacity and pressure?
Your Answer: (Not answered)
Correct Answer: D (Maintain the prescribed pressure at the fire main with the required number of hydrants in simultaneous use)
💡 SOLAS requires the emergency fire pump to maintain the prescribed pressure and reach at the fire main with the required number of hydrants in simultaneous use, so that effective firefighting is possible in an emergency.
✗
Question 23. What inputs does a management review of the safety management system normally include?
Your Answer: (Not answered)
Correct Answer: A (Internal and external audit results, accident and near miss analysis, handling of non-conformities and feedback on the system)
💡 Inputs to a management review normally include the results of internal and external audits, the analysis of accidents and near misses, non-conformities and their correction, the effectiveness of training, the implementation of the previous review's decisions and feedback from the crew and outside, from which the effectiveness of the system is assessed and improvements decided.
✗
Question 24. What items does the stability assessment after loading include?
Your Answer: (Not answered)
Correct Answer: D (Initial metacentric height, the righting lever curve, the maximum righting lever and the weather criterion)
💡 Intact stability assessment normally includes the initial metacentric height, the shape and range of the righting lever curve, the maximum righting lever and its angle and the weather criterion, the ratio of heeling to righting moment. Calculating the initial metacentric height alone does not ensure intact stability.
✗
Question 25. What is the usual maximum validity of a Cargo Ship Safety Radio Certificate?
Your Answer: (Not answered)
Correct Answer: B (Five years, with periodical surveys)
💡 Under SOLAS I/12 the Cargo Ship Safety Radio Certificate has a usual validity of not more than five years, with periodical surveys as required. The performance and provision of the radio installation, including distress alerting, communications and the reserve source of energy, are the focus of the survey.
✗
Question 26. Emergency lighting was tested and some survival craft embarkation stations had no lighting. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: C (Embarkation stations, survival craft stowage positions and the water alongside must be lit from the emergency source)
💡 SOLAS requires embarkation stations, survival craft stowage positions and the water alongside to be illuminated from the emergency source of power, ensuring safe abandonment. Torches are not a substitute for fixed emergency lighting.
✗
Question 27. The intermediate verification of a Safety Management Certificate shall be carried out:
Your Answer: (Not answered)
Correct Answer: A (around the mid-point of the certificate's validity)
💡 SOLAS IX/4 (ISM) requires intermediate verification around the mid-point of the SMC validity.
✗
Question 28. A PSC inspection checked the enhanced survey documentation of a tanker. What document does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (A survey programme identifying the scope of close-up survey and thickness measurement)
💡 The ESP requires the ship to hold a survey programme specifying the extent of close-up survey and thickness measurement, agreed by the class society and the owner. A survey or thickness report alone does not evidence the existence and execution of the programme.
✗
Question 29. Regarding main and emergency sources of electrical power, which statement is correct?
Your Answer: (Not answered)
Correct Answer: A (the emergency source comes into operation automatically upon failure of the main source)
💡 SOLAS II-1 requires the emergency source to come into operation automatically upon failure of the main source, being independent from it.
✗
Question 30. A PSC inspection found a lifeboat equipment locker locked with the key not in the boat. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: A (Equipment of survival craft must be ready for immediate use and must not be locked away)
💡 SOLAS requires survival craft equipment to be ready for immediate use. Locking it away or storing it elsewhere means it cannot be reached promptly in an abandonment, contrary to the readiness requirement, and is a deficiency.
✗
Question 31. What should be done if the loading instrument of a bulk carrier computes abnormally?
Your Answer: (Not answered)
Correct Answer: D (Stop relying on it and use an approved manual method or shore support, repairing and verifying it as soon as possible)
💡 If a loading instrument computes abnormally, such as results clearly differing from hand calculation or the program reporting errors, reliance on it should cease and an approved manual method or shore support used to complete the strength and stability checks, with the instrument repaired and verified as soon as possible, preventing a wrong result from causing overloading or structural damage.
✗
Question 32. What marking shall life-saving appliances and their stowage positions have?
Your Answer: (Not answered)
Correct Answer: A (Clear markings for quick identification in an emergency)
💡 Markings shall identify the appliances and their stowage positions.
✗
Question 33. Regarding lifeboat provision for cargo ships, which is correct?
Your Answer: (Not answered)
Correct Answer: D (lifeboats for all persons on board shall be provided on each side)
💡 SOLAS III/31 requires lifeboats for all persons on each side of a cargo ship, or liferafts meeting equivalent conditions.
✗
Question 34. What preparation does SOLAS and good seamanship require before heavy weather?
Your Answer: (Not answered)
Correct Answer: C (Check and secure deck and hold cargo, close watertight openings and adjust course and speed to reduce impact)
💡 Before heavy weather, cargo securing should be checked, watertight openings closed and course and speed adjusted to reduce hull stress, with the ship's condition monitored, limiting the risk of structural damage and cargo shift.
✗
Question 35. Outside an emission control area, what is generally the sulphur limit of fuel oil used on board?
Your Answer: (Not answered)
Correct Answer: A (0.50 per cent m/m)
💡 Under MARPOL Annex VI the global sulphur limit for fuel oil used on board has been 0.50 per cent m/m since 2020, while within an emission control area such as the Baltic, North Sea, North American and United States Caribbean areas it is 0.10 per cent m/m. Using low-sulphur fuel or an equivalent arrangement is acceptable.
✗
Question 36. An echo sounder shall be fitted on:
Your Answer: (Not answered)
Correct Answer: D (passenger ships on international voyages and cargo ships of 500 GT and above)
💡 SOLAS V/19: passenger ships on international voyages and cargo ships of 500 GT and above shall be fitted with an echo sounder.
✗
Question 37. What is the meaning and use of an H class division?
Your Answer: (Not answered)
Correct Answer: A (The highest grade of fire-resisting division in the standard test, used for high risk boundaries such as pump rooms on tankers)
💡 An H class division is the highest grade of fire-resisting division under SOLAS, used for high risk boundaries such as the boundaries of cargo pump rooms on tankers. It exceeds class A performance and must retain structural integrity after the test.
✗
Question 38. What is required for the height of liferaft stowage?
Your Answer: (Not answered)
Correct Answer: A (Stowed at a height allowing the raft to float free and allowing persons to board and handle it)
💡 A liferaft should be stowed at a height that allows it to float free, clear of deck structures, and that permits persons to board and handle it, normally on a dedicated rack on the boat deck. Too high makes boarding difficult; too low risks damage by seas or prevents free floating.
✗
Question 39. After a ship is detained by PSC, what is the correct course of action?
Your Answer: (Not answered)
Correct Answer: D (Rectify the deficiencies before departure and apply for a re-inspection, fulfilling the duty to report to the flag State, the recognised organisation and the company)
💡 A detained ship should rectify the deficiencies before departure, or within the permitted period, apply for a port State re-inspection and be confirmed before leaving, and report to the flag State, recognised organisation and company as required with the rectification plan. Sailing without rectification aggravates the consequences and affects the future PSC record.
✗
Question 40. How does the position of the centre of gravity affect cargo stowage?
Your Answer: (Not answered)
Correct Answer: D (The higher the cargo, the higher the centre of gravity, the smaller the initial metacentric height and the poorer the stability; cargo should not be concentrated high)
💡 The higher the cargo, the higher the ship's centre of gravity, the smaller the initial metacentric height and the less the reserve of stability, making capsize more likely in rough weather. Stowage should avoid concentrating cargo high up, particularly on a tween deck, and the resulting height of the centre of gravity should be checked against the permissible value.
✗
Question 41. What does SOLAS and the related rules address regarding cargo ventilation?
Your Answer: (Not answered)
Correct Answer: B (Ventilating appropriately according to the nature of the cargo, preventing self-heating, harmful gas accumulation or condensation damage)
💡 SOLAS and the IMSBC Code require the method and timing of ventilation to suit the cargo: some need ventilation to remove heat, others must not be ventilated to avoid moisture uptake or increased self-heating. Ventilating blindly may make matters worse.
✗
Question 42. A watertight door is found unable to be closed remotely from the bridge. The finding is?
Your Answer: (Not answered)
Correct Answer: A (Watertight doors must be remotely closable with indication of their open or closed position; failure affects subdivision integrity)
💡 Where subdivision requires it a watertight door, especially a remotely controlled one, must be capable of remote closure from the central control station on the bridge with position indication there. Loss of remote control affects the ability to close doors rapidly and maintain subdivision integrity in the event of flooding. It is a deficiency to be corrected.
✗
Question 43. Which persons are not counted as passengers under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (Children under one year of age)
💡 Children under one year of age are not counted.
✗
Question 44. If a ship fails a survey because of an equipment deficiency, what may the Administration do?
Your Answer: (Not answered)
Correct Answer: B (Require rectification within a period and re-inspect afterwards, with the validity of the certificate possibly affected meanwhile)
💡 SOLAS I/12 permits the Administration to suspend or withdraw a certificate where the ship does not comply. In practice rectification within a period and re-inspection is required before validity is maintained or restored. A certificate must not be issued with a deficiency outstanding.
✗
Question 45. Rescue boat recovery appliances shall be capable of recovering the rescue boat with persons and equipment at ship's headway of up to:
Your Answer: (Not answered)
Correct Answer: B (5 knots)
💡 SOLAS III/16 requires recovery at ship's headway of up to 5 knots.
✗
Question 46. What minimum speed must a powered rescue boat be capable of maintaining in calm water with its full complement aboard?
Your Answer: (Not answered)
Correct Answer: B (6 knots)
💡 SOLAS III/17 requires a powered rescue boat to maintain at least 6 knots for not less than 4 hours. Four knots is a frequently confused figure.
✗
Question 47. Besides the ship, where else shall life-saving appliances be provided?
Your Answer: (Not answered)
Correct Answer: A (One full set at the shore establishment)
💡 A full set shall also be kept at the shore establishment.
✗
Question 48. What measures do SOLAS and the IMSBC Code require for solid bulk cargoes liable to self-heat or release harmful gas?
Your Answer: (Not answered)
Correct Answer: A (Obtain full cargo information before loading, increase ventilation and gas testing and restrict entry into the holds)
💡 The IMSBC Code requires precautions for cargoes liable to self-heat or release harmful gas: full cargo information, increased ventilation and gas testing, restricted entry into the holds and emergency preparation, preventing spontaneous combustion, poisoning or explosion.
✗
Question 49. Which back-up arrangements are accepted when ECDIS is used to satisfy the chart carriage requirement?
Your Answer: (Not answered)
Correct Answer: C (A full folio of up-to-date paper charts or a second ECDIS with independent power supply)
💡 SOLAS V/19 requires adequate back-up for ECDIS, normally a full folio of corrected paper charts or a second ECDIS with independent power supply. Internal files or a CD do not constitute adequate back-up.
✗
Question 50. With regard to charts, which requirement is correct?
Your Answer: (Not answered)
Correct Answer: A (up-to-date charts covering the intended voyage shall be carried)
💡 SOLAS V/27 requires up-to-date charts covering the intended voyage.
✗
Question 51. What is the total embarkation and launching time for survival craft on a passenger ship?
Your Answer: (Not answered)
Correct Answer: B (Not more than 30 minutes from the abandon ship signal)
💡 Within 30 minutes of the abandon ship signal.
✗
Question 52. What shall the radio log essentially contain?
Your Answer: (Not answered)
Correct Answer: C (Records of distress, urgency and safety communications and equipment failures)
💡 Records of distress and safety communications and equipment failures.
✗
Question 53. What fire rating does SOLAS normally require for the boundary between a category A machinery space and accommodation spaces?
Your Answer: (Not answered)
Correct Answer: D (A-60 class division)
💡 SOLAS normally requires A-60 class boundaries between category A machinery spaces and accommodation and service spaces because of the high fire risk in machinery spaces.
✗
Question 54. An emergency generator starts in 60 seconds. What is the SOLAS requirement?
Your Answer: (Not answered)
Correct Answer: A (Within 45 seconds; 60 seconds does not comply)
💡 SOLAS II-1/41 requires the emergency generator to start automatically and connect to the emergency switchboard within 45 seconds of the main source failing. Sixty seconds exceeds the limit and requires adjustment or repair.
✗
Question 55. Which is the MF digital selective calling distress frequency?
Your Answer: (Not answered)
Correct Answer: A (2187.5 kHz)
💡 2187.5 kHz is the MF DSC distress frequency; 2182 kHz is the MF radiotelephony distress frequency.
✗
Question 56. What must be confirmed before releasing a fixed extinguishing system?
Your Answer: (Not answered)
Correct Answer: A (That all persons have left the space and been accounted for, that ventilation is closed and that the system is in working order)
💡 Before releasing a fixed extinguishing system such as CO2, it must be confirmed that all persons have left the space and been accounted for, that ventilation and openings are closed to prevent loss of gas and that the pressure or weight of the system is correct. Any omission could cause fatalities or failure of the system.
✗
Question 57. In what condition must a lifeboat be kept while stowed?
Your Answer: (Not answered)
Correct Answer: C (In a condition of immediate readiness for launching, with securing arrangements that can be released quickly without impairing safety)
💡 SOLAS requires a lifeboat when stowed to be ready for immediate launching: equipment complete on board, a gravity davit in a releasable condition and securing arrangements that hold the boat secure at sea yet can be released quickly in an emergency. Multiple lashings or dismantled parts would delay abandonment.
✗
Question 58. Which watertight doors may be used for passage during navigation?
Your Answer: (Not answered)
Correct Answer: A (Sliding watertight doors)
💡 Sliding watertight doors may be used during navigation; other watertight doors shall be kept closed.
✗
Question 59. Which equipment does a ship in sea area A3 use to receive maritime safety information and satisfy GMDSS?
Your Answer: (Not answered)
Correct Answer: A (An enhanced group calling (EGC) receiver)
💡 Beyond NAVTEX coast station coverage, a ship in sea area A3 must use EGC to receive SafetyNET MSI. NAVTEX is available only within A1 and A2 coverage.
✗
Question 60. What special requirement applies to life-saving appliances on ships operating in polar waters?
Your Answer: (Not answered)
Correct Answer: A (They must function at low temperature, with measures to extend survival time taken into account)
💡 The Polar Code requires life-saving appliances to function at low temperatures and for measures to be taken to extend survival time, such as thermal protection and collective survival equipment. Ordinary water requirements alone do not suffice.
✗
Question 61. Survival craft launching appliances shall be capable of being operated:
Your Answer: (Not answered)
Correct Answer: B (under unfavourable conditions of trim and list)
💡 SOLAS III/16 requires launching appliances to operate under unfavourable conditions of trim and list.
✗
Question 62. Navigation publications required under SOLAS include:
Your Answer: (Not answered)
Correct Answer: C (charts, sailing directions and notices to mariners)
💡 SOLAS V/27 requires adequate charts, nautical publications and notices to mariners.
✗
Question 63. What protection is required when taking shore power in port?
Your Answer: (Not answered)
Correct Answer: A (Confirm voltage, frequency and phase sequence match, with insulation checked and proper earthing, preventing damage and electric shock)
💡 Before taking shore power, the voltage, frequency and phase sequence should be confirmed to match, with the cable insulation checked, reliable earthing established and earth leakage protection fitted. Once connected, the phase sequence should be verified to prevent motors running backwards and the equipment confirmed to operate normally, preventing damage and electric shock.
✗
Question 64. For SOLAS purposes, a passenger ship is one which carries more than how many passengers?
Your Answer: (Not answered)
Correct Answer: A (More than 12)
💡 SOLAS I/2: a passenger ship carries more than 12 passengers; children under one year are not counted.
✗
Question 65. A ship with a single deck, top side tanks and hopper side tanks carrying grain in bulk is what under SOLAS XII/1?
Your Answer: (Not answered)
Correct Answer: D (A bulk carrier subject to the requirements of Chapter XII)
💡 SOLAS XII/1 defines a bulk carrier as a ship with a single deck, top side tanks and hopper side tanks intended primarily to carry dry cargo in bulk. A grain carrier meets these characteristics and must comply with Chapter XII, including structural strength information and water ingress detection.
✗
Question 66. A cargo ship is 140 m in length with a crew of 20. What capacity must the survival craft on each side provide under SOLAS III/31?
Your Answer: (Not answered)
Correct Answer: D (Each side must accommodate all 20 persons on board)
💡 SOLAS III/31 requires the survival craft on each side of a cargo ship to accommodate all persons on board, so that everyone can escape whichever side is unusable. Counting the total for both sides only is not sufficient.
✗
Question 67. Water-tight doors shall be capable of being operated watertight:
Your Answer: (Not answered)
Correct Answer: D (At all times)
💡 Water-tight doors must be capable of being closed watertight at all times and kept closed during navigation.
✗
Question 68. Emergency lighting shall come into operation automatically:
Your Answer: (Not answered)
Correct Answer: C (on failure of the normal lighting)
💡 SOLAS II-1/42-43 requires emergency lighting to come into operation automatically upon failure of the main source.
✗
Question 69. At what trim shall launching appliances be able to operate?
Your Answer: (Not answered)
Correct Answer: A (10° trim)
💡 At 10 degrees of trim, together with the corresponding list.
✗
Question 70. What is the responsibility of the GMDSS radio operator on board?
Your Answer: (Not answered)
Correct Answer: C (Distress, urgency and safety communications, with watchkeeping and recording as required)
💡 Under SOLAS IV and STCW, the holder of a GMDSS certificate is responsible for distress, urgency and safety communications and watchkeeping, and handles public correspondence under the master's authority.
✗
Question 71. What insulation monitoring is required for the electrical system?
Your Answer: (Not answered)
Correct Answer: B (Insulation monitoring means such as a switchboard insulation resistance meter or monitor, detecting a fall promptly)
💡 SOLAS requires means of insulation monitoring, such as an insulation resistance meter on the main switchboard or an insulation monitor, giving continuous or periodic indication of the insulation to earth and an alarm when it falls, so that leakage and faults are found in time.
✗
Question 72. While a pilot is on board, the officer of the watch should:
Your Answer: (Not answered)
Correct Answer: D (Maintain a proper look-out and monitor the pilot's actions)
💡 The OOW remains responsible and must monitor the pilot and keep a proper look-out.
✗
Question 73. What does SOLAS address regarding ventilator coamings and closing appliances on deck?
Your Answer: (Not answered)
Correct Answer: A (Coamings must be of the prescribed height with effective closing appliances, preventing entry of sea water)
💡 SOLAS and the Load Line Convention require deck ventilator coamings to be of the prescribed height with effective closing appliances, preventing sea water from entering when the deck is swept or the ship lists, which would cause flooding and loss of stability.
✗
Question 74. What time limits apply to launching and recovering a rescue boat?
Your Answer: (Not answered)
Correct Answer: B (Launching and recovery, when loaded, each within 5 minutes)
💡 Launching and recovery when fully loaded shall each be within 5 minutes.
✗
Question 75. What is the required sequence in a simulated fire alarm during a fire drill?
Your Answer: (Not answered)
Correct Answer: A (Discovering the fire, raising the alarm, mustering, establishing the situation and firefighting, with responsibilities at each stage clear)
💡 A fire drill should follow the full sequence: raising the alarm on discovering the fire, including use of manual call points, mustering under the muster list, establishing the location and nature of the fire, firefighting and search under the master's or the on-scene commander's orders and releasing the fixed system if necessary, so that the stages connect smoothly.
✗
Question 76. With regard to the IMO Ship Identification Number, it shall be:
Your Answer: (Not answered)
Correct Answer: B (permanent and marked on the hull)
💡 SOLAS XI-1/3: a ship shall have a permanent IMO Ship Identification Number marked on the hull and shown on certificates.
✗
Question 77. What does SOLAS V/19.2.3 require for the heading indication of a ship?
Your Answer: (Not answered)
Correct Answer: B (A duly adjusted magnetic compass or other suitable means of determining and displaying the heading)
💡 SOLAS V/19.2.3 requires an adjusted magnetic compass or other approved means of determining and displaying heading. GPS gives course over ground and cannot replace heading indication.
✗
Question 78. What do SOLAS and STCW emphasise about the crew's performance in emergency drills?
Your Answer: (Not answered)
Correct Answer: C (Familiarity with their duties in the muster list, reaching their station within the prescribed time and performing correctly)
💡 SOLAS and STCW require each crew member to be familiar with his duties in the muster list, to reach his station within the prescribed time and to perform correctly. The purpose of a drill is to ensure that this capability actually exists.
✗
Question 79. What separation is required between control stations such as the bridge or fire control station and accommodation spaces?
Your Answer: (Not answered)
Correct Answer: A (Normally A-60 or A-30 class divisions, so the control station remains usable in a fire)
💡 Control stations provide command and fire control functions in an emergency, so SOLAS requires A-60 or A-30 boundaries with accommodation spaces according to their position, ensuring they remain usable.
✗
Question 80. A magnetic compass deviation curve is found not updated within the required period. The finding is?
Your Answer: (Not answered)
Correct Answer: A (The magnetic compass must be swung and its deviation curve drawn periodically; being overdue makes the heading reference unreliable)
💡 The magnetic compass is one of the key heading references and should be swung and its deviation curve drawn at the required intervals, the deviation changing with the magnetic state of the ship. Being overdue means the indicated heading carries an unknown error. If relied on as the primary heading reference it may endanger navigational safety. It is a deficiency to be corrected.
✗
Question 81. What do SOLAS and the related rules emphasise for position fixing in ice or polar waters?
Your Answer: (Not answered)
Correct Answer: A (Cross-check by several means, since compass and position fixing equipment may be affected by magnetic variation and signal conditions in polar regions)
💡 Magnetic variation is large in polar regions and satellite signals may be affected by ionospheric conditions. SOLAS and good seamanship require the position and heading to be cross-checked by several means, avoiding the risk from a single equipment error.
✗
Question 82. What does SOLAS address regarding automatic change-over of the radio reserve source?
Your Answer: (Not answered)
Correct Answer: D (The reserve source must connect automatically or be switched promptly according to procedure when the main source fails)
💡 SOLAS requires the radio reserve source to be connected automatically or switched promptly under the procedure when the main source fails, keeping distress communication capability uninterrupted. A change-over needing lengthy manual action would interrupt emergency communication.
✗
Question 83. What does the annual inspection of an extinguisher include?
Your Answer: (Not answered)
Correct Answer: D (Checking pressure or weight, the seal and pin, the hose and nozzle and corrosion of the body, with records kept)
💡 SOLAS and good practice require the annual inspection of an extinguisher to cover internal pressure or weight, detecting leakage, the condition of the pin and seal, the freedom of the hose and nozzle and corrosion or damage of the body, with records and marking.
✗
Question 84. The shipper shall provide the ship with cargo information before loading, including:
Your Answer: (Not answered)
Correct Answer: A (information necessary for proper stowage and securing, such as weight and stowage factor)
💡 SOLAS VI/5: the shipper shall provide, before loading, information necessary for proper stowage and securing such as weight and stowage factor.
✗
Question 85. Which publications shall the master use before departure and during the voyage for safe navigation?
Your Answer: (Not answered)
Correct Answer: D (Charts, sailing directions and associated publications)
💡 SOLAS V/34: the master shall use charts, sailing directions, light lists and other relevant publications.
✗
Question 86. What is the principle for the audit requirements of the Document of Compliance (DOC)?
Your Answer: (Not answered)
Correct Answer: C (Validity generally not more than five years with an annual audit within three months before or after each anniversary date)
💡 Under the ISM Code a company's Document of Compliance has a usual validity of not more than five years with an annual audit within three months before or after each anniversary date, to confirm the continued effective operation of the company's safety management system. A failed annual audit affects the ship's SMC.
✗
Question 87. What is the main purpose of the main engine and steering gear information required on board?
Your Answer: (Not answered)
Correct Answer: B (To enable the master to know the machinery and steering response and plan safe manoeuvres)
💡 SOLAS requires information on the main engine and steering gear so the master understands acceleration, deceleration and steering response, and can plan berthing and narrow channel manoeuvres.
✗
Question 88. What is required for lubrication and maintenance of launching appliances?
Your Answer: (Not answered)
Correct Answer: B (Periodic lubrication of moving parts and checking of sheave and pin wear as the manufacturer requires, with records kept)
💡 SOLAS requires periodic lubrication of the moving parts of launching appliances and checking of sheave and pin wear and freedom of movement as the manufacturer's instructions require, with maintenance recorded. Lack of maintenance leaves the appliance liable to seize or fail in an emergency.
✗
Question 89. How should the master deal with a cargo liable to liquefy whose moisture content exceeds the transportable moisture limit?
Your Answer: (Not answered)
Correct Answer: D (Refuse to load, or take measures permitted by the Code such as re-consigning or trimming and drainage before loading)
💡 The IMSBC Code recognises that a cargo liable to liquefy with moisture above the TML may liquefy at sea and capsize the ship. The master must refuse to load or take approved measures to bring the cargo within limits, never load on the chance it will be all right.
✗
Question 90. What is the focus when navigating in or near ice under SOLAS V and related requirements?
Your Answer: (Not answered)
Correct Answer: B (Enhanced look-out, reduced speed and attention to hull stress and changing ice conditions)
💡 Navigation in ice calls for enhanced look-out, controlled speed and continuous monitoring of ice conditions and hull condition to avoid damage. Increasing speed or switching off aids worsens the risk.
✗
Question 91. What is the principle for the inspection and maintenance of portable fire extinguishers?
Your Answer: (Not answered)
Correct Answer: B (Their pressure, seals, nozzles and securing should be checked regularly, with maintenance or recharging at the required intervals and records kept)
💡 Under SOLAS II-2/10 and the maintenance requirements portable fire extinguishers should have their pressure indication, seals, nozzles and securing checked regularly and be maintained or recharged at the required intervals, by an approved service provider where applicable, with records kept, ensuring they are always available.
✗
Question 92. What must be considered in manning a ship for polar waters?
Your Answer: (Not answered)
Correct Answer: A (The greater difficulty of operations, the long search and rescue response times and the demands of working in low temperature)
💡 The Polar Code requires account to be taken of the greater difficulty of operations in polar regions, limited search and rescue resources with long response times and the demands of working and responding in low temperature, ensuring sufficient and trained personnel to cope in an emergency.
✗
Question 93. After a collision, besides assisting the persons on the other vessel, what should be done?
Your Answer: (Not answered)
Correct Answer: C (Check the damage and flooding of own ship, assess safety and report to those concerned, preserving evidence as needed)
💡 After a collision, while assisting the persons on the other vessel provided own ship is safe, the damage and flooding should be checked, stability and safety assessed, those concerned informed and evidence preserved as needed, such as VDR data, logs and photographs. Leaving the scene or failing to assist may constitute an offence.
✗
Question 94. Ships shall be provided with means to determine their position, which may include:
Your Answer: (Not answered)
Correct Answer: D (adequate means such as radar, ECDIS or GPS to fix position)
💡 SOLAS V/19 requires adequate means to determine the ship's position.
✗
Question 95. A VDR shall record:
Your Answer: (Not answered)
Correct Answer: D (date/time, position, speed, heading, bridge audio and other data)
💡 SOLAS V/20: a VDR records date/time, position, speed, heading, radar images and bridge audio.
✗
Question 96. What is required for checking the tightness of hatch covers on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Periodic inspection of seals, cleats and drain channels with a hose test to verify weathertightness)
💡 SOLAS requires the hatch covers of a bulk carrier to remain weathertight, with periodic checks of seal ageing, the effectiveness of cleats and the clearance of drain channels, and a hose test where necessary to verify tightness, preventing sea water from entering the holds and damaging structure and cargo.
✗
Question 97. What does SOLAS address regarding fuel for lifeboat engines?
Your Answer: (Not answered)
Correct Answer: B (Fuel with a flashpoint of not less than 43 degrees Celsius, and tank capacity allowing the boat to run at the prescribed speed for a specified time)
💡 SOLAS requires lifeboat engines to use fuel with a flashpoint of not less than 43 degrees Celsius, reducing fire risk, and a tank capacity allowing the boat to run at the prescribed speed for a specified period, ensuring mobility after abandonment.
✗
Question 98. If a DSC alert in sea area A1 receives no response, what does GMDSS procedure require?
Your Answer: (Not answered)
Correct Answer: C (Make a radiotelephony distress call on VHF channel 16 and try other means available)
💡 If a DSC alert is not acknowledged, a radiotelephony distress call should be made on VHF channel 16 or MF 2182 kHz, at the same time or afterwards, and other means such as satellite or HF tried, ensuring the alert is received. Channel 70 must not be used for speech.
✗
Question 99. What fire precautions apply during cargo operations on a tanker?
Your Answer: (Not answered)
Correct Answer: A (Control vapour emission, prohibit hot work and spark-producing operations and keep the inert gas and firefighting equipment available)
💡 During cargo operations on a tanker, vapour emission should be controlled, for example by recovery or discharge to a safe position, hot work and spark-producing operations such as hammering or the use of non-protected tools must be prohibited in the cargo area, and the inert gas system and firefighting equipment kept available.
✗
Question 100. What is the role of the voyage data recorder in casualty investigation?
Your Answer: (Not answered)
Correct Answer: B (Providing data such as position, course and speed, radar images and bridge audio for investigation)
💡 SOLAS requires the VDR to record navigational and operational data including position, course and speed, radar images, bridge audio and alarms, providing objective evidence for investigation. The data is protected and must not be used at will.