Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. Which statement about the purpose of the international shore connection is correct?
Your Answer: (Not answered)
Correct Answer: A (To enable water to be supplied to the ship's fire main from the shore or another ship if necessary, its dimensions being internationally standardised)
💡 Under SOLAS II-2/10 the relevant ships should carry at least one international shore connection so that, if necessary, the ship's fire main can be connected to the fire system of the shore or another ship for an external supply of water. Its dimensions should be standardised and its accessories such as bolts and gaskets complete and properly stowed.
✗
Question 2. When loading solid bulk cargoes liable to liquefy, care must be taken to prevent:
Your Answer: (Not answered)
Correct Answer: B (Water accumulation in the holds)
💡 Accumulated water can cause liquefaction, so trimming and drainage are essential.
✗
Question 3. What pressure testing does the fire main require?
Your Answer: (Not answered)
Correct Answer: B (Periodic pressure testing, normally annually, confirming no leakage in the piping and valves at the rated pressure)
💡 SOLAS and good practice require periodic pressure testing of the fire main, normally annually at not less than the design working pressure, confirming that the piping, valves and joints show no leakage or deformation under pressure, ensuring a reliable water supply in a fire.
✗
Question 4. Under SOLAS XI-2/8, the master has:
Your Answer: (Not answered)
Correct Answer: A (ultimate responsibility for the safety and security of the ship, and may take decisions and request assistance)
💡 SOLAS XI-2/8: the master has ultimate responsibility for the safety and security of the ship and may take decisions and request assistance.
✗
Question 5. Lifeboat launching drills shall be conducted:
Your Answer: (Not answered)
Correct Answer: B (under sailing conditions as well, to train the crew in emergency operations)
💡 SOLAS III/19: lifeboat launching drills shall be conducted under sailing conditions as well, so as to train the crew in actual operation.
✗
Question 6. The main functions of an Inmarsat ship earth station include:
Your Answer: (Not answered)
Correct Answer: C (distress alerting, communication and reception of maritime safety information)
💡 SOLAS IV/7 requires an Inmarsat ship earth station for distress alerting, communication and reception of MSI.
✗
Question 7. Under SOLAS V/33, the master:
Your Answer: (Not answered)
Correct Answer: A (shall proceed with all speed to assist upon receiving a distress message, unless doing so would seriously endanger the ship and persons on board)
💡 SOLAS V/33: the master shall proceed with all speed to assist upon receiving a distress message unless doing so would seriously endanger the ship and persons on board.
✗
Question 8. Boundaries of machinery spaces shall be constructed of:
Your Answer: (Not answered)
Correct Answer: C (A class divisions)
💡 SOLAS II-2/9 requires machinery space boundaries of A class divisions.
✗
Question 9. How do the fire protection requirements for the cargo area of a chemical tanker differ from those of an oil tanker?
Your Answer: (Not answered)
Correct Answer: D (The extinguishing medium must be chosen according to the properties of the chemicals carried, with water or foam prohibited for certain cargoes)
💡 Because chemicals vary greatly in reactivity, SOLAS and the IBC Code require the extinguishing medium to suit the cargo. Some cargoes react with water or liberate toxic gas, so water or foam is prohibited.
✗
Question 10. A ship carrying bulk grain must satisfy which stability requirement?
Your Answer: (Not answered)
Correct Answer: C (The stability requirements of the International Grain Code)
💡 SOLAS VI/8: bulk grain carriers must comply with the International Grain Code stability requirements.
✗
Question 11. How does the survey programme change as a bulk carrier ages under SOLAS and the ESP?
Your Answer: (Not answered)
Correct Answer: D (The scope and frequency increase with age, particularly close-up survey and thickness measurement)
💡 The ESP prescribes the survey scope by age band, requiring more as the ship grows older, including wider close-up survey and thickness measurement, to assess corrosion and fatigue and decide on repair or reinforcement.
✗
Question 12. What should a maintenance programme for radio equipment include?
Your Answer: (Not answered)
Correct Answer: B (Daily checks, periodic tests, spares provision and repair arrangements, either ashore or on board)
💡 SOLAS requires the availability of radio equipment to be ensured by daily checks, periodic tests, spare parts and either a shore-based maintenance agreement or at-sea maintenance capability, with the maintenance programme reflecting these arrangements and verified at survey.
✗
Question 13. What is the requirement for the lifeline in a firefighter's outfit?
Your Answer: (Not answered)
Correct Answer: B (A fire-resisting lifeline of adequate length and strength for rescue use)
💡 SOLAS requires a fire-resisting lifeline of adequate length and strength for searching for and rescuing persons in smoke. An ordinary rope does not have the necessary fire resistance.
✗
Question 14. How should training needs be identified and met?
Your Answer: (Not answered)
Correct Answer: C (Identified from the operation of the system, drills and inspections and then delivered)
💡 The ISM Code and STCW require the company and the ship to identify training needs from drill assessments, findings at inspection and the analysis of accidents and near misses, such as unfamiliarity with equipment or unclear emergency duties, and to organise targeted training and assessment, so that training matches the actual need.
✗
Question 15. What is required in forming main vertical zones?
Your Answer: (Not answered)
Correct Answer: C (Dividing the ship into sections by class A divisions so that fire in one section is restricted from spreading to adjacent sections)
💡 SOLAS requires main vertical zones formed by class A divisions, dividing the ship into sections so that a fire is confined to the zone in which it starts. This is the core of structural fire protection.
✗
Question 16. In preparing a voyage plan, consideration shall be given to:
Your Answer: (Not answered)
Correct Answer: D (navigational hazards, safe speed, collision avoidance and contingency measures)
💡 SOLAS V/34 requires the voyage plan to consider navigational hazards, safe speed, avoidance and contingency measures.
✗
Question 17. How shall portable extinguishers be positioned?
Your Answer: (Not answered)
Correct Answer: A (Readily accessible within the space without obstructing escape)
💡 They shall be readily accessible without impeding escape.
✗
Question 18. What should the crew do after the abandon ship alarm is sounded?
Your Answer: (Not answered)
Correct Answer: A (Act in accordance with the duties in the muster list, taking the designated items to the muster station and awaiting orders)
💡 On the abandon ship alarm the crew acts under the muster list: taking the designated emergency items such as lifejackets, certificates and the log and reporting to the muster station, with the master or the officer in charge deciding whether to abandon and the order of boarding. No one acts independently.
✗
Question 19. What does the periodic test of launching appliances at intervals not exceeding five years involve?
Your Answer: (Not answered)
Correct Answer: A (A launching test with the rated complement or prescribed load, verifying performance under load)
💡 SOLAS III/35 requires a test with load, at the rated complement or an equivalent, at intervals of not exceeding five years, actually verifying the reliability of the brake, release gear and structure under load. An empty or static test does not meet the requirement.
✗
Question 20. What fire precautions apply at a galley range?
Your Answer: (Not answered)
Correct Answer: D (Combustibles must be kept clear of the range, with a filter and fixed extinguishing system in the hood and effective ventilation)
💡 SOLAS and good practice require combustibles such as cloths and cartons to be kept clear of the galley range, a filter and fixed extinguishing system in the hood and effective ventilation, with flammable liquids not stored near the range, reducing the risk of fire.
✗
Question 21. What are the requirements on the use of the emergency steering position?
Your Answer: (Not answered)
Correct Answer: A (steering taken on there quickly when bridge control fails, communication with the bridge kept, and the crew made familiar with the position and its handling by drill)
💡 The emergency position is in the steering gear space and exists so the ship can still be steered when control from the bridge has failed. It must be lit and fed from a supply that does not depend on the main source, have a sound means of communication with the bridge, show the position of the rudder, and be operated in a way the person on watch can take at once, direct control of the valves or the gear as the case may be, after practice. The drill programme covers the changeover from bridge control and how long it takes. To leave the work to the engineer alone with the officer writing down times, or to treat the position as a drill item never to be used in earnest, misses what it is there for.
✗
Question 22. Safe speed is judged by whether the ship can:
Your Answer: (Not answered)
Correct Answer: A (Stop within a distance appropriate to the circumstances and prevailing conditions)
💡 Stop within a distance appropriate to the prevailing circumstances and conditions.
✗
Question 23. Which fixed system is normally provided for oil fires in machinery spaces?
Your Answer: (Not answered)
Correct Answer: A (A fixed high expansion foam, low pressure CO2 or equivalent system)
💡 SOLAS requires a fixed extinguishing system in category A machinery spaces, normally fixed high expansion foam, low pressure CO2 or an equivalent system. Portable extinguishers are not a substitute.
✗
Question 24. What communication is required when entering an enclosed space?
Your Answer: (Not answered)
Correct Answer: B (Continuous communication with the standby person, including periodic contact, with immediate withdrawal if it is lost)
💡 SOLAS and the IMO resolutions require the entrant to maintain continuous communication with the standby person at the entrance, normally by agreed periodic contact, and to withdraw at once if communication cannot be restored, preventing an incident from going unnoticed.
✗
Question 25. If unable to assist, the master receiving a distress alert shall:
Your Answer: (Not answered)
Correct Answer: D (Endeavour to relay the alert to units able to assist)
💡 Endeavour to relay the alert to units able to render assistance.
✗
Question 26. Why should the length and diameter of fire hoses meet the requirements?
Your Answer: (Not answered)
Correct Answer: B (To ensure the hose reaches the protected space, is easy to handle and does not affect discharge pressure)
💡 A fire hose should be of appropriate length and diameter: too long increases friction loss and reduces pressure, too short cannot reach the protected space. Every hydrant's hose should reach any position in the protected space requiring it and be suitable for operation by two persons.
✗
Question 27. What should be noted about using the lifeboat compass at night?
Your Answer: (Not answered)
Correct Answer: A (It must have a light enabling it to be read at night without impairing night vision)
💡 A lifeboat compass should have a light that does not impair night vision, such as red or dimmable illumination, so that a course can be kept at night after abandonment. A compass without a light is unusable at night and greatly reduces the chance of being found.
✗
Question 28. What do SOLAS and the related rules emphasise for position fixing in ice or polar waters?
Your Answer: (Not answered)
Correct Answer: A (Cross-check by several means, since compass and position fixing equipment may be affected by magnetic variation and signal conditions in polar regions)
💡 Magnetic variation is large in polar regions and satellite signals may be affected by ionospheric conditions. SOLAS and good seamanship require the position and heading to be cross-checked by several means, avoiding the risk from a single equipment error.
✗
Question 29. What is the role of the designated person ashore under the ISM Code?
Your Answer: (Not answered)
Correct Answer: D (To provide a direct link between the company and those on board, monitoring safety and pollution prevention)
💡 ISM Code 4 requires the company to designate a person ashore providing a direct link with the ship and monitoring safety and pollution prevention. Command remains with the master.
✗
Question 30. Sea area A2 means an area, excluding sea area A1, within the coverage of at least one:
Your Answer: (Not answered)
Correct Answer: C (MF coast station with continuous alerting capability)
💡 SOLAS IV/2: Sea area A2 is the area, excluding A1, within the coverage of at least one MF coast station with continuous DSC alerting.
✗
Question 31. When encountering ice or icebergs, a ship shall:
Your Answer: (Not answered)
Correct Answer: B (navigate with caution, report as necessary and keep a safe distance)
💡 SOLAS V/31-32 requires monitoring of ice, cautious navigation and reporting.
✗
Question 32. What is the requirement for the total capacity of fire pumps?
Your Answer: (Not answered)
Correct Answer: A (It shall be sufficient to supply the required jets at the minimum pressure)
💡 Pumps shall supply the required jets at the prescribed minimum pressure.
✗
Question 33. What should be done if the stowage factor does not suit the ship's hold capacity?
Your Answer: (Not answered)
Correct Answer: D (Adjust the quantity loaded according to hold capacity and stability limits, loading in stages or re-allocating the cargo if necessary)
💡 If the cargo is of large stowage factor and the holds are insufficient, or of small stowage factor so that the hull is overstressed, the quantity loaded or the stowage plan should be adjusted according to capacity, stability and strength limits. Loading regardless would cause overloading or insufficient stability.
✗
Question 34. What is required regarding the bridge navigational watch alarm system?
Your Answer: (Not answered)
Correct Answer: D (All passenger ships and ships of 150 GT and above)
💡 All passenger ships and ships of 150 GT and above.
✗
Question 35. What is the core issue addressed by the International Grain Code in relation to stability?
Your Answer: (Not answered)
Correct Answer: D (The effect on stability of heeling moments arising from grain shifting and settling during the voyage)
💡 The International Grain Code requires the heeling moments from grain shifting and settling to be calculated and the residual stability verified for the prescribed angles of heel, preventing excessive list from grain shift.
✗
Question 36. What may result from insufficient height of the hatch coaming?
Your Answer: (Not answered)
Correct Answer: B (Water shipping into the hold)
💡 The coaming height is set so that shipping or sea water cannot enter the hold.
✗
Question 37. What do SOLAS and the related conventions address regarding ballast system safety and pollution prevention?
Your Answer: (Not answered)
Correct Answer: C (Reliable control of ballast intake and discharge, preventing inadvertent changes to stability or pollution)
💡 Ballast operations must follow the plan strictly and be recorded, preventing inadvertent valve operation from cross-connecting tanks, causing a sudden change in stability, or discharging oily ballast and polluting the environment. Ballast water management must also meet the relevant convention requirements.
✗
Question 38. When inerting the cargo tanks of a tanker, what is the usual upper limit for the oxygen content of the tank atmosphere?
Your Answer: (Not answered)
Correct Answer: A (Not more than five per cent by volume)
💡 Under SOLAS II-2/4 and the related requirements, when the cargo tanks of a tanker are inerted the oxygen content of the tank atmosphere should be held below five per cent by volume so that a flammable mixture cannot form. The inert gas system should maintain a positive tank pressure and monitor the oxygen content, and the operation should stop if the limit is exceeded.
✗
Question 39. The inert gas system shall be capable of delivering inert gas at a total capacity of at least what percentage of the maximum discharge rate?
Your Answer: (Not answered)
Correct Answer: C (125%)
💡 SOLAS II-2/5 requires the inert gas system to deliver inert gas at not less than 125% of the maximum discharge rate.
✗
Question 40. What does COLREG require for crossing a traffic lane in a routeing scheme?
Your Answer: (Not answered)
Correct Answer: C (Cross as nearly as practicable at right angles to the lane and avoid impeding vessels following the lane)
💡 COLREG Rule 10 requires a vessel crossing a traffic lane to do so as nearly as practicable at right angles to the general direction of traffic flow and to avoid impeding vessels following the lane. Diagonal or contrary navigation disrupts the flow and increases the risk of collision.
✗
Question 41. A cargo pump room on a tanker shall be protected by:
Your Answer: (Not answered)
Correct Answer: C (an approved fixed gas, foam or pressure water-spraying system)
💡 SOLAS II-2/10: a cargo pump room on a tanker shall be protected by an approved fixed gas, foam or pressure water-spraying system.
✗
Question 42. The VDR is found not to have recorded the bridge audio and radar images of the recent voyage. The finding is?
Your Answer: (Not answered)
Correct Answer: C (The VDR must continuously record the required data; failure to record affects accident investigation)
💡 The VDR is used to reconstruct the navigation and decisions at the time of an accident and should continuously record the required data, such as position, speed, radar images, bridge audio and alarms. Failure to record key data deprives an accident investigation of its basis. It is a deficiency to be corrected.
✗
Question 43. What is the first action if dangerous goods catch fire on board?
Your Answer: (Not answered)
Correct Answer: D (Raise the alarm, establish the nature of the cargo from the EmS Guide and select the appropriate extinguishing medium, with protection of personnel)
💡 A dangerous goods fire requires the alarm to be raised at once and the nature of the cargo established from the EmS Guide, with the extinguishing medium selected accordingly, since some cargoes react with water or liberate toxic gas and water is prohibited. Personnel must be protected and evacuated, and blind use of water or a close approach avoided.
✗
Question 44. What does SOLAS address regarding the fire and weathertight requirements for ventilators?
Your Answer: (Not answered)
Correct Answer: D (Closing devices must be fitted, able to shut off ventilation when required and maintain weathertightness)
💡 SOLAS requires ventilators to have closing devices that both shut off ventilation to control a fire and maintain weathertightness against the entry of sea water. A rain hood alone meets neither requirement.
✗
Question 45. Which extinguisher is least suitable for a galley cooking oil fire?
Your Answer: (Not answered)
Correct Answer: C (Direct water jets)
💡 Water on a fat fire causes splashing and reignition; a blanket or fat-fire agent must be used.
✗
Question 46. What does the weekly inspection of a lifeboat require regarding the engine?
Your Answer: (Not answered)
Correct Answer: A (Start and run it for the prescribed period, checking starting, running and cooling)
💡 SOLAS requires the boat engine to be started and run for the prescribed period, normally not less than three minutes, during the weekly inspection, checking that it starts readily, runs smoothly and discharges cooling water properly. An appearance or level check alone would not reveal an actual fault.
✗
Question 47. What is the purpose of the radar reflector among the lifeboat equipment?
Your Answer: (Not answered)
Correct Answer: C (To increase the radar echo of the boat so that it is detected by searching vessels)
💡 SOLAS requires a lifeboat to carry a radar reflector, increasing the radar echo so that searching vessels detect the boat at a greater distance, improving the chance of rescue.
✗
Question 48. What fire precautions are required before bunkering?
Your Answer: (Not answered)
Correct Answer: A (Confirm firefighting equipment in place, close relevant openings, clear deck of oil and establish communication with the barge)
💡 Before bunkering, firefighting equipment such as extinguishers, hoses and absorbents should be in place, openings through which oil could enter should be closed and the deck kept free of oil, with communication and an agreed emergency stop arranged with the supplier, preventing overflow and fire.
✗
Question 49. A PSCO tested ventilation closing devices and found some seized. What does SOLAS address?
Your Answer: (Not answered)
Correct Answer: A (Closing devices of machinery space ventilators must close rapidly to cut off ventilation and air supply)
💡 SOLAS II-2 requires machinery space ventilator closing devices to close rapidly and remain effective, cutting off the air supply in a fire. Seized devices or a lack of regular testing are common deficiencies.
✗
Question 50. What must the cargo securing manual contain under SOLAS VI/5 and the CSS Code?
Your Answer: (Not answered)
Correct Answer: C (Securing methods for the various cargo units, specifications of securing equipment and methods of strength verification)
💡 SOLAS VI/5 and the CSS Code require the cargo securing manual to contain the securing methods for the various cargo units, the specification and number of securing devices, methods of strength verification and inspection requirements, for correct securing by the crew.
✗
Question 51. What identification is required for fire main isolation valves?
Your Answer: (Not answered)
Correct Answer: A (Clear marking of their position and direction of operation, enabling prompt and correct action in a fire)
💡 SOLAS requires fire main isolation valves to be clearly marked as to position and direction of operation, so that in an emergency the crew can find them quickly and correctly isolate the section affected. Missing or wrong marking delays firefighting.
✗
Question 52. What departure preparations do SOLAS and good seamanship require to be confirmed?
Your Answer: (Not answered)
Correct Answer: B (Certificates and equipment condition, the passage plan and chart corrections, cargo securing and the draught and stability condition)
💡 Before departure, valid certificates, availability of critical equipment, the passage plan, corrected charts and a cargo and ballast condition within stability and strength limits should all be confirmed. Any omission may become an incident at sea.
✗
Question 53. What does SOLAS address regarding drainage of ro-ro spaces?
Your Answer: (Not answered)
Correct Answer: A (Effective drainage removing firefighting water and leaked oil promptly)
💡 SOLAS requires ro-ro spaces to have effective drainage and storage arrangements able to remove firefighting water and leaked oil promptly, preventing free surface from affecting stability and reducing the risk of oil spreading the fire.
✗
Question 54. On what is the effectiveness of the system judged?
Your Answer: (Not answered)
Correct Answer: D (The achievement of objectives, the trend in non-conformities, changes in accidents and near misses and the crew's grasp of the system)
💡 The effectiveness of the system should be judged on the achievement of safety and pollution prevention objectives, the number and trend of non-conformities, the occurrence and nature of accidents and near misses and the crew's grasp of the system and their duties, together with the quality of internal audits and management reviews, not merely on certificates or on passing an audit.
✗
Question 55. The 15ppm oil content meter alarm is inoperative and the automatic discharge stopping function does not operate. The finding is?
Your Answer: (Not answered)
Correct Answer: C (Loss of monitoring and automatic stop means an over-limit discharge cannot be prevented; a serious deficiency)
💡 The 15ppm oil content meter and the automatic discharge stopping device are key equipment for controlling the discharge of bilge water. The failure of the alarm and of the automatic stop means that an over-limit discharge cannot be automatically prevented and an illegal discharge may result. It is a serious deficiency affecting pollution prevention.
✗
Question 56. How many rocket parachute flares must each survival craft carry?
Your Answer: (Not answered)
Correct Answer: A (4)
💡 SOLAS III/7.1 requires four rocket parachute flares in each survival craft. Six is the usual number for hand flares, which is easily confused with this.
✗
Question 57. What is the effect of contamination of a fire detector by oil fume or dust?
Your Answer: (Not answered)
Correct Answer: C (It may cause false alarms or reduced sensitivity leading to a missed alarm, so periodic cleaning and maintenance are required)
💡 A detector contaminated by oil, dust or moisture may give frequent false alarms or lose sensitivity and miss an alarm. It should therefore be cleaned and function tested at the prescribed intervals, especially in heavily contaminated spaces such as the galley and machinery space.
✗
Question 58. Under specific conditions, how long may an Administration generally extend a short-term certificate?
Your Answer: (Not answered)
Correct Answer: D (Three months)
💡 Under SOLAS I/14 an Administration may, in specific circumstances, extend a certificate, generally not exceeding three months, the relevant survey being completed within the period and a new certificate issued. Extension is not exemption from survey but a short transitional arrangement.
✗
Question 59. Fire hoses shall be provided:
Your Answer: (Not answered)
Correct Answer: B (for each hydrant in sufficient number, including spare hoses)
💡 SOLAS II-2/10: fire hoses shall be provided for each hydrant in sufficient number, including spare hoses.
✗
Question 60. A cargo ship completed its renewal survey in June 2020. Under SOLAS I/10, when must the subsequent annual surveys be held?
Your Answer: (Not answered)
Correct Answer: D (Every 12 months, within three months before or after the anniversary date)
💡 SOLAS I/10 requires annual surveys every 12 months, normally within a window of three months before or after the anniversary date.
✗
Question 61. What does SOLAS address regarding surface materials on bulkheads in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: A (They must restrict flame spread and meet the prescribed requirements for non-combustibility and low flame spread)
💡 SOLAS II-2 prescribes requirements for non-combustibility and low flame spread for the surfaces of bulkheads, ceilings and linings, preventing rapid spread of flame over surfaces. The materials must be approved.
✗
Question 62. How should the officer of the watch allow for wind and current when navigating in harbour waters?
Your Answer: (Not answered)
Correct Answer: A (Consider the drift caused by wind and current, keep a margin and apply rudder in good time)
💡 Harbour waters are confined and wind and current cause lateral drift. The officer should anticipate their direction and strength, adjust course and speed early and keep a handling margin, avoiding being set down onto a berth or into shoal water.
✗
Question 63. An extinguisher's gauge needle is in the red zone. What should be done?
Your Answer: (Not answered)
Correct Answer: B (Establish the cause and recharge or replace it; an under-pressured extinguisher cannot discharge effectively)
💡 A needle in the red zone means internal pressure is too low, perhaps through leakage or use, so the extinguisher may discharge weakly or not at all. It must be recharged or replaced at once; recharging by the crew is not permitted.
✗
Question 64. What are the restrictions on non-protected portable equipment in tanker cargo tanks?
Your Answer: (Not answered)
Correct Answer: D (Equipment such as ordinary torches or non-protected radios may not be used where vapour may accumulate)
💡 Vapour may accumulate in the cargo tanks, pump room and adjacent spaces of a tanker, so equipment that may produce a spark, such as ordinary torches, non-protected radios, power tools and camera flashes, is prohibited. Intrinsically safe or explosion-protected equipment must be used.
✗
Question 65. What is required for maintenance and inspection of radio equipment?
Your Answer: (Not answered)
Correct Answer: A (Periodic inspection and maintenance to keep it ready for use)
💡 Periodic inspection and maintenance to keep it available at all times.
✗
Question 66. What separation is required for the deck between accommodation spaces and a machinery space?
Your Answer: (Not answered)
Correct Answer: A (Normally A-60 class, protecting a high fire risk boundary)
💡 SOLAS requires A-60 class boundaries between category A machinery spaces and accommodation spaces. Because the fire risk in machinery spaces is high, the strongest protection is required to prevent spread to the accommodation.
✗
Question 67. What does SOLAS II-2 require for paint lockers and flammable liquid lockers?
Your Answer: (Not answered)
Correct Answer: C (A suitable fire-extinguishing arrangement, such as a fixed system or equivalent)
💡 SOLAS II-2/15 requires paint and flammable liquid lockers to be provided with a suitable extinguishing arrangement because of the high fire load and rapid spread in such spaces.
✗
Question 68. How should life-saving appliances other than lifeboats and liferafts be distributed?
Your Answer: (Not answered)
Correct Answer: B (One full set on board and one at the shore establishment)
💡 SOLAS III/21: the quantity shall be sufficient to provide one set for all on board and one at the shore establishment.
✗
Question 69. Dangerous goods shall be stowed:
Your Answer: (Not answered)
Correct Answer: A (in accordance with the IMDG Code, with segregation to prevent dangerous reactions)
💡 SOLAS VII/3 requires stowage and segregation of dangerous goods in accordance with the IMDG Code.
✗
Question 70. How is the company security officer appointed?
Your Answer: (Not answered)
Correct Answer: B (Designated by the company, responsible for the security of its ships)
💡 ISPS Code Part A/11 requires the company security officer to be designated by the company, ensuring that ship security assessments and plans are effectively implemented. Neither the master nor the port may make the appointment.
✗
Question 71. What do SOLAS and the related handbooks emphasise about assembling survival craft after abandonment?
Your Answer: (Not answered)
Correct Answer: A (Craft should stay together where possible, maintaining contact and acting in a coordinated way to aid detection)
💡 SOLAS and survival craft handbooks favour keeping the craft together or close, permitting coordinated action, mutual support and easier detection by rescuers. Scattering is not recommended.
✗
Question 72. What is the requirement for the safety lamp in a firefighter's outfit?
Your Answer: (Not answered)
Correct Answer: D (An electric safety lamp capable of continuous illumination for at least three hours)
💡 SOLAS requires an electric safety lamp giving continuous illumination for at least three hours, safe in smoke and flammable atmospheres. Ordinary torches and flame lamps are not acceptable.
✗
Question 73. What should be noted when using VHF for port communication?
Your Answer: (Not answered)
Correct Answer: A (Use the designated port channels, keep transmissions concise and end them promptly, maintaining a watch on channel 16)
💡 Port communication should use the designated channels, such as the berthing, pilot and VTS frequencies, with concise standard phraseology and transmissions ended promptly, while a watch is kept on channel 16 for distress and safety traffic. Channel 16 must not be occupied at length.
✗
Question 74. Emergency lighting batteries are found of insufficient capacity so that the lights cannot last the required time after a power failure. The finding is?
Your Answer: (Not answered)
Correct Answer: A (Emergency lighting cannot last the required duration, a deficiency affecting escape and operational safety)
💡 Emergency lighting, including the emergency source of power, must last the required duration after the main power fails so as to light escape routes, muster stations, engine room escapes and essential operations. Insufficient capacity defeats this function and is a deficiency to be corrected.
✗
Question 75. Which MF frequency is used for DSC distress alerting?
Your Answer: (Not answered)
Correct Answer: A (2187.5 kHz)
💡 The MF DSC distress frequency is 2187.5 kHz. 2182 kHz is the MF radiotelephony distress frequency and 2174.5 kHz is used for NBDP distress traffic.
✗
Question 76. Which statement about the remote starting of fire pumps is correct?
Your Answer: (Not answered)
Correct Answer: C (Fire pumps should be capable of being started remotely from the bridge or fire control station, or readily started locally, for prompt water supply)
💡 Under SOLAS II-2/10 fire pumps should be capable of being started from the bridge or fire control station, or otherwise ensured to start promptly and supply the fire main in a fire. The means of starting should be stated in the operating instructions, with which the crew should be familiar. The emergency fire pump should have an independent source of power and self-priming capability.
✗
Question 77. What is the principle for the inspection and maintenance of portable fire extinguishers?
Your Answer: (Not answered)
Correct Answer: B (Their pressure, seals, nozzles and securing should be checked regularly, with maintenance or recharging at the required intervals and records kept)
💡 Under SOLAS II-2/10 and the maintenance requirements portable fire extinguishers should have their pressure indication, seals, nozzles and securing checked regularly and be maintained or recharged at the required intervals, by an approved service provider where applicable, with records kept, ensuring they are always available.
✗
Question 78. What analysis and records are required if a voyage plan is not followed exactly?
Your Answer: (Not answered)
Correct Answer: B (Analyse the cause, such as avoidance, sheltering or a fault, assess the effect and record it, revising the plan if necessary)
💡 Where the execution of a voyage plan deviates, the reason should be analysed, whether avoidance, sheltering, an equipment fault or a temporary task, the effect on the remaining passage and safety assessed and the matter recorded, with the remaining plan revised as appropriate, such as updating waypoints or adjusting timing, keeping the plan consistent with what is being done.
✗
Question 79. Fire hydrant couplings shall:
Your Answer: (Not answered)
Correct Answer: D (be compatible so that hydrants, hoses and nozzles on the same ship are interchangeable)
💡 SOLAS II-2/10: hydrant couplings, hoses and nozzles on the same ship shall be interchangeable.
✗
Question 80. Rescue boat recovery appliances shall be capable of recovering the rescue boat with persons and equipment at ship's headway of up to:
Your Answer: (Not answered)
Correct Answer: B (5 knots)
💡 SOLAS III/16 requires recovery at ship's headway of up to 5 knots.
✗
Question 81. What is the purpose of sailing directions among the nautical publications required on board?
Your Answer: (Not answered)
Correct Answer: C (To provide written information on navigational conditions, dangers and coastal features of the area)
💡 Sailing directions give written information on navigational conditions, dangers, ports and coastal features, complementing the charts, and are among the publications required by SOLAS.
✗
Question 82. The purpose of a thermal protective aid is to:
Your Answer: (Not answered)
Correct Answer: A (reduce body heat loss of a person in water or after rescue)
💡 SOLAS III/32 requires thermal protective aids to reduce body heat loss.
✗
Question 83. What fire protection is required in the cargo area of a gas carrier?
Your Answer: (Not answered)
Correct Answer: A (Gas detection and alarm, intrinsically safe or explosion-protected electrical equipment and safety devices protecting the cargo containment system)
💡 SOLAS and the IGC Code require the cargo area of a gas carrier to have flammable gas detection and alarm, intrinsically safe or explosion-protected electrical equipment and devices protecting the pressure and temperature of the cargo containment system, preventing accumulation of leaks and overpressure.
✗
Question 84. What frequency does a satellite EPIRB use?
Your Answer: (Not answered)
Correct Answer: A (406 MHz)
💡 406 MHz.
✗
Question 85. Under SOLAS V/8, what follows from a breach of the regulations?
Your Answer: (Not answered)
Correct Answer: A (Responsibility follows and regard shall be had to navigational dangers)
💡 Responsibility follows and regard shall be had to navigational dangers.
✗
Question 86. When must the Polar Water Operational Manual be updated?
Your Answer: (Not answered)
Correct Answer: A (On major changes to the ship or its equipment and on updates to the relevant requirements of the Polar Code)
💡 The Polar Code requires the PWOM to be revised on major changes to the ship, its equipment or its operations, and when the relevant requirements are updated, keeping it consistent with the actual situation. Operating from an out-of-date manual creates risk.
✗
Question 87. What does SOLAS II-2 require regarding combustible materials in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: B (Surface materials and furnishings must be restricted in combustibility and comply with prescribed flame spread requirements)
💡 SOLAS II-2 limits the combustibility of bulkheads, ceilings, deck coverings and furniture in accommodation spaces, reducing fire load and the rate of spread.
✗
Question 88. What is the first action after a fire breaks out at sea?
Your Answer: (Not answered)
Correct Answer: B (Raise the fire alarm at once, inform the bridge, organise firefighting per the muster list and consider reporting and seeking assistance)
💡 On discovering a fire, the fire alarm must be raised at once and firefighting organised under the muster list, with the bridge and master informed. The situation is then assessed to decide whether to seek assistance from nearby vessels or ashore and whether to alter course or speed, for example to keep the seat of the fire downwind. Delaying the alarm is not acceptable.
✗
Question 89. In a narrow channel, a vessel engaged in fishing shall not impede:
Your Answer: (Not answered)
Correct Answer: A (any other vessel which can navigate only within the narrow channel)
💡 SOLAS V/27: in a narrow channel, a vessel engaged in fishing shall not impede any vessel which can navigate only within that channel.
✗
Question 90. What capability should the bridge retain when navigating in ice?
Your Answer: (Not answered)
Correct Answer: D (The ability to manoeuvre at any time at an appropriate speed, with engines on standby if necessary)
💡 Navigation in ice requires engines on standby, controlled speed and the ability to manoeuvre at any time, avoiding damage from changing ice conditions. Driving at full speed or shutting down the engine carries serious risk.
✗
Question 91. What protection is required when handling corrosive cargo on a chemical tanker?
Your Answer: (Not answered)
Correct Answer: C (Appropriate protective equipment such as acid-resistant gloves, face protection and protective clothing, with washing facilities available)
💡 SOLAS and the IBC Code require appropriate personal protective equipment for handling corrosive or toxic chemicals, such as resistant gloves, face and eye protection and protective clothing, with emergency washing facilities available for prompt treatment on contact. The ship should carry her own protective equipment.
✗
Question 92. What does SOLAS address regarding the use of watertight doors in drills?
Your Answer: (Not answered)
Correct Answer: A (Closing and remote operation of watertight doors should be practised in drills so the crew is familiar with the procedure)
💡 SOLAS requires the closing and remote operation of watertight doors to be practised in drills, so that the crew is familiar with the procedure and the operating positions for closing doors in an emergency. A briefing alone does not ensure correct operation when it matters.
✗
Question 93. The securing of cargo units such as containers shall be carried out in accordance with:
Your Answer: (Not answered)
Correct Answer: A (the approved Cargo Securing Manual)
💡 SOLAS VI/5 requires securing of cargo units in accordance with the approved Cargo Securing Manual.
✗
Question 94. With regard to bridge visibility, SOLAS requires that:
Your Answer: (Not answered)
Correct Answer: B (a clear view of the sea surface forward shall be available from the conning position, not obstructed by cargo or structure)
💡 SOLAS V/22 requires a clear forward view from the conning position, unobstructed by cargo or structure.
✗
Question 95. What does SOLAS address regarding the function of the double bottom in the event of damage?
Your Answer: (Not answered)
Correct Answer: B (The inner space limits flooding and protects the inner bottom structure when the bottom is damaged)
💡 One of the principal reasons SOLAS requires a double bottom is that when the bottom is damaged by grounding or stranding, the double bottom space limits the extent of flooding and protects the inner bottom structure, reducing the volume of water admitted and improving survivability.
✗
Question 96. What do SOLAS and the IBC Code address regarding the operation of the inert gas system?
Your Answer: (Not answered)
Correct Answer: D (It must remain in operation with tank pressure and oxygen content monitored during cargo, ballast and tank cleaning operations)
💡 SOLAS and the IBC Code require the inert gas system to remain in operation during cargo handling, ballasting and tank washing, with the oxygen content and pressure of each tank monitored continuously. If limits are exceeded, operations must stop to avoid the risk of explosion.
✗
Question 97. In the periodic inspection of lifeboat davits, what does SOLAS require particular attention to?
Your Answer: (Not answered)
Correct Answer: B (Structural corrosion, sheave wear and the reliability of limit switches and release gear)
💡 Davit inspection concentrates on structural corrosion, wear of sheaves and falls, and the reliability of limit switches and on-load release gear, all of which determine whether the boat can be launched safely.
✗
Question 98. An Exemption Certificate shall generally be valid for the same period as:
Your Answer: (Not answered)
Correct Answer: B (the relevant safety certificate)
💡 SOLAS I/4 provides that an Exemption Certificate is generally valid for the same period as the relevant certificate.
✗
Question 99. Which system, directly related to fire protection, is required in accommodation and service spaces?
Your Answer: (Not answered)
Correct Answer: B (Fixed fire detection and alarm system)
💡 SOLAS II-2/12 requires fixed fire detection and alarm systems in accommodation and service spaces.
✗
Question 100. What do SOLAS and the related conventions address regarding sewage treatment systems?
Your Answer: (Not answered)
Correct Answer: D (The plant must operate and discharge in accordance with the requirements, with attention to the risk of harmful gas)
💡 A sewage treatment plant must be operated and discharge in accordance with MARPOL, and attention paid to the harmful gases which may be produced in the process. The relevant spaces should be ventilated, entry restricted and testing carried out as prescribed to prevent poisoning.