Question 1. How must Class 1 explosives be segregated from Class 4 flammable solids?
Your Answer: (Not answered)
Correct Answer: B (Segregation is required as set out in the Code and the Cargo Securing Manual)
💡 Incompatible dangerous goods must be segregated in accordance with the Code and the Cargo Securing Manual.
✗
Question 2. After a ship has been detained by PSC, when is the detention lifted?
Your Answer: (Not answered)
Correct Answer: B (When the detainable deficiencies have been rectified and verified by re-inspection)
💡 Detention is lifted only when the detainable deficiencies have been rectified and confirmed by re-inspection. An undertaking, security or plan cannot substitute for actual rectification.
✗
Question 3. What does 'Company' mean in SOLAS?
Your Answer: (Not answered)
Correct Answer: A (The shipowner or an organization which has assumed responsibility for operation)
💡 It means the owner or any organization which has assumed responsibility for the ship's operation.
✗
Question 4. What does SOLAS address regarding sounding and observation arrangements for fuel oil tanks?
Your Answer: (Not answered)
Correct Answer: C (Safe and reliable measuring arrangements, preventing oil from overflowing or spraying out)
💡 SOLAS requires fuel oil tank measuring arrangements to be safe and reliable, such as self-closing sounding pipes or closed level gauges, preventing oil from overflowing or spraying onto hot surfaces during measurement and causing fire.
✗
Question 5. When is a Declaration of Security concluded?
Your Answer: (Not answered)
Correct Answer: D (When security levels differ between ship and port facility, or the interface risk is high)
💡 ISPS Code A/5: a DoS is concluded when levels differ or the security risk at the interface is high.
✗
Question 6. The Continuous Synopsis Record (CSR) is intended to:
Your Answer: (Not answered)
Correct Answer: C (record the history and major events of the ship such as changes of name, owner and class)
💡 SOLAS XI-1/3: the Continuous Synopsis Record records the history and major events of the ship such as changes of name, owner and class.
✗
Question 7. After grounding, what should the master give priority to?
Your Answer: (Not answered)
Correct Answer: D (Ascertain the extent of flooding and damage, assess stability and pollution risk, prevent further damage and pollution and report)
💡 After grounding the first priority is to ascertain the flooding of compartments, the damage to the hull and the ship's position, assess stability, the grounding forces and the pollution risk, and take measures to prevent further damage and pollution, such as closing watertight doors, controlling draught and trim, informing those concerned and reporting. Forcing a refloat at once may worsen the damage and must be carefully assessed.
✗
Question 8. On what principle are the types of portable extinguishers chosen?
Your Answer: (Not answered)
Correct Answer: C (The medium must suit the class of fire likely in the space, such as foam or dry powder in the machinery space)
💡 SOLAS requires extinguishers to be provided according to the class of fire likely in each space: foam, dry powder or CO2 for oil fires in the machinery space, water-based or dry powder in accommodation and non-conducting media where electrical equipment is present. The wrong choice means the extinguisher is ineffective.
✗
Question 9. On receiving a distress signal at sea, what shall the master do if the ship is able to assist?
Your Answer: (Not answered)
Correct Answer: A (Proceed with all speed to assist)
💡 SOLAS V/33: the master shall proceed with all speed to assist persons in distress when able to do so.
✗
Question 10. Besides the muster station, what else must the muster list specify?
Your Answer: (Not answered)
Correct Answer: D (The specific duty assigned to each crew member in an emergency)
💡 SOLAS III/37 requires the muster list to specify the duty of each crew member in an emergency and the muster station, and to identify the crew assigned to each survival craft.
✗
Question 11. When checking the firefighter's outfits the breathing apparatus cylinder pressure is found below 80 percent of the rated value. The finding is?
Your Answer: (Not answered)
Correct Answer: A (The breathing apparatus cannot guarantee the required duration of use, a deficiency to be corrected)
💡 An insufficient pressure in the self-contained breathing apparatus cylinder means the required duration of use cannot be guaranteed, directly weakening the ability of a firefighter to enter a fire area. On inspection a cylinder pressure below the rated value is recorded as a deficiency and refilling or replacement is required.
✗
Question 12. What is the primary purpose of ships' routeing under SOLAS V/10?
Your Answer: (Not answered)
Correct Answer: B (To improve safety of navigation and reduce the risk of collision and grounding)
💡 SOLAS V/10 states that the purpose of ships' routeing is to improve safety of navigation and reduce the risk of collision, not to delimit jurisdiction or increase speed.
✗
Question 13. What does SOLAS III require for lighting at embarkation stations?
Your Answer: (Not answered)
Correct Answer: C (Lighting supplied from the emergency source, illuminating the station and the water alongside)
💡 SOLAS III/11 requires embarkation stations, survival craft stowage positions and the water alongside to be lit from the emergency source, so abandonment and night recovery are safe. Torches are not an acceptable substitute.
✗
Question 14. A cargo ship has completed one fire drill this month. When at the latest should the next one be held?
Your Answer: (Not answered)
Correct Answer: B (Within the next month, since a cargo ship holds at least one a month)
💡 Under SOLAS III/19 each crew member of a cargo ship should take part in at least one fire drill and one abandon-ship drill each month, while passenger ships hold them weekly. The interval for a cargo ship is therefore one month, and missing it is an emergency preparedness deficiency.
✗
Question 15. What is the purpose of the ship security assessment?
Your Answer: (Not answered)
Correct Answer: C (To identify security risks and weaknesses of the ship, forming the basis for the ship security plan)
💡 ISPS Code Part A/6 requires a ship security assessment identifying security risks, weaknesses and possible threats, the results of which form the basis for developing and updating the ship security plan.
✗
Question 16. What does sea area A4 cover?
Your Answer: (Not answered)
Correct Answer: A (The area outside sea areas A1, A2 and A3, principally polar waters with no satellite coverage)
💡 Sea area A4 means the area outside A1, A2 and A3, principally polar waters beyond Inmarsat coverage. It is not a collective term for all sea areas.
✗
Question 17. What is the SOLAS requirement regarding independence of means for transmitting distress alerts?
Your Answer: (Not answered)
Correct Answer: B (At least two separate and independent means shall be available)
💡 SOLAS IV/4: at least two separate and independent means shall be available for transmitting distress alerts.
✗
Question 18. What does SOLAS require regarding the verified gross mass of containers?
Your Answer: (Not answered)
Correct Answer: B (The shipper must provide the verified gross mass to the master before loading, and a container without a verified mass must not be loaded)
💡 SOLAS VI/2 requires the shipper to provide the verified gross mass before loading, and a container without a verified mass may not be loaded, preventing stack collapse, structural damage and injury from overweight containers.
✗
Question 19. What is the purpose of electronic position fixing and navigation systems such as satellite systems on board?
Your Answer: (Not answered)
Correct Answer: A (To provide continuous position and navigation information supporting navigation and collision avoidance)
💡 Electronic position fixing systems such as satellite systems provide continuous position, course and speed information forming the basis of navigation and collision avoidance. Their accuracy and reliability must be monitored and cross-checked.
✗
Question 20. What does SOLAS require where ventilation ducts pass through fire divisions?
Your Answer: (Not answered)
Correct Answer: D (Fire dampers must be fitted and the fire integrity of the division maintained at the penetration)
💡 SOLAS II-2/9 requires fire dampers and maintenance of the fire integrity of the division at penetrations. Poorly protected penetrations become paths for fire spread.
✗
Question 21. What operational requirement relates to ballast water and SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Ballasting according to stability and strength requirements, preventing excessive hogging or sagging and insufficient stability)
💡 Ballast operations must follow stability and strength requirements so the ship keeps an appropriate draught, trim and stability. Excessive ballast or a poor sequence overstresses the hull, so the loading plan must be followed.
✗
Question 22. What should be noted in using sound and light signals to indicate intentions?
Your Answer: (Not answered)
Correct Answer: A (Use them as prescribed, watch for conflict with the other vessel's intentions and coordinate by VHF if necessary)
💡 Sound and light signals should be used as prescribed when vessels are in sight of one another to indicate manoeuvring intentions or to propose a course of action, but they do not replace actual avoiding action. After making a signal the other vessel's response should be watched and VHF used to coordinate if necessary, preventing conflicting intentions.
✗
Question 23. What is the purpose of the line-throwing appliance among life-saving appliances?
Your Answer: (Not answered)
Correct Answer: A (To throw a line over a required distance so that contact can be established with another ship or the shore)
💡 SOLAS requires a line-throwing appliance capable of throwing a line over a prescribed distance, normally not less than 230 m, to establish contact with a casualty or the shore.
✗
Question 24. What shall be the relationship between the main and emergency sources of power?
Your Answer: (Not answered)
Correct Answer: A (They are independent and the emergency source takes over automatically)
💡 They shall be independent and the emergency source shall take over automatically.
✗
Question 25. In SOLAS I/2 the expression "upright position" is used to define which condition of the ship?
Your Answer: (Not answered)
Correct Answer: B (The reference condition with no heel, used for measuring freeboard and similar particulars)
💡 SOLAS and the Load Line Convention take the upright (no heel) condition as the datum for measuring moulded depth, freeboard and similar particulars, irrespective of the loading condition.
✗
Question 26. What does SOLAS require for each fire hose?
Your Answer: (Not answered)
Correct Answer: D (Each hose must have a nozzle and be stowed near its hydrant ready for use)
💡 SOLAS requires each fire hose to be fitted with a nozzle and stowed near its hydrant so that it can be connected and used at once. Stowing hoses and nozzles separately delays firefighting.
✗
Question 27. What medical care is required on board?
Your Answer: (Not answered)
Correct Answer: A (Prescribed medicines and medical equipment, access to medical guides and personnel trained in first aid)
💡 SOLAS and the MLC require a ship to carry the prescribed medicines and medical equipment, determined by the trading area and the number of crew, to keep the International Medical Guide for Ships and access to medical advice available and to have crew trained in first aid and medical care, so that basic treatment can be given on board.
✗
Question 28. Regarding main and emergency sources of electrical power, which statement is correct?
Your Answer: (Not answered)
Correct Answer: A (the emergency source comes into operation automatically upon failure of the main source)
💡 SOLAS II-1 requires the emergency source to come into operation automatically upon failure of the main source, being independent from it.
✗
Question 29. Which measure prevents static hazards in the cargo area of a tanker?
Your Answer: (Not answered)
Correct Answer: D (Earthing of piping and tanks and similar anti-static measures)
💡 Earthing of piping and tanks and other anti-static measures.
✗
Question 30. When a pilot is on board, how is responsibility allocated?
Your Answer: (Not answered)
Correct Answer: A (The pilot provides pilotage and advice but does not relieve the master of responsibility for the safety of the ship)
💡 A pilot on board provides local pilotage and manoeuvring advice but does not relieve the master of responsibility for the safety of the ship. The master and officer of the watch should still monitor the ship's movement and, if the pilot's orders are likely to cause danger, should speak up promptly and take necessary action.
✗
Question 31. If the master finds a defect affecting safe navigation that cannot be repaired on board, the first action is to:
Your Answer: (Not answered)
Correct Answer: A (Report to the Company and arrange repair)
💡 The master should report to the Company so that repair can be arranged and the voyage adjusted.
✗
Question 32. A fire in the machinery space has ruptured the fire main within that space. What is the purpose of the isolation valves fitted on the fire main?
Your Answer: (Not answered)
Correct Answer: A (To isolate the damaged section so the remainder of the main stays charged)
💡 SOLAS II-2/10.2 requires isolation valves so that a damaged section can be cut off while the rest of the fire main remains supplied with water.
✗
Question 33. What should be done if a problem is found with a breathing apparatus face mask?
Your Answer: (Not answered)
Correct Answer: B (Replace it if perished, damaged or not sealing, otherwise it leaks and the apparatus fails)
💡 A face mask that is perished, damaged or not sealing will let the wearer inhale toxic smoke and must be replaced at once. Repair by tape or other temporary means cannot ensure airtightness and is a deficiency affecting the safety of firefighters.
✗
Question 34. What fire precautions apply to tank cleaning on a tanker?
Your Answer: (Not answered)
Correct Answer: C (Follow the approved procedure, controlling static electricity, maintaining inerting and monitoring tank gas and oxygen content)
💡 Crude oil washing or water washing should follow the approved procedure, controlling jet velocity and the generation of static electricity by limiting nozzle pressure and maintaining earthing, keeping the tanks inerted and monitoring hydrocarbon concentration and oxygen content, preventing static discharge from igniting vapour.
✗
Question 35. What is the emergency bilge suction for?
Your Answer: (Not answered)
Correct Answer: B (Dewatering the machinery space using the main engine cooling pump)
💡 It allows the machinery space to be dewatered using the main cooling or sea water pump.
✗
Question 36. The steering gear takes 35 seconds to move the rudder from 35 degrees one side to 30 degrees the other. What is the finding?
Your Answer: (Not answered)
Correct Answer: B (It exceeds the prescribed 28 seconds and does not comply; the steering gear performance must be investigated)
💡 SOLAS II-1/29 requires the main steering gear, at maximum service speed and deepest seagoing draught, to complete the movement from 35 degrees one side to 30 degrees the other within 28 seconds. Thirty five seconds exceeds the limit and indicates a problem with the power or control capability of the steering gear.
✗
Question 37. What is required for the frequency of position checks?
Your Answer: (Not answered)
Correct Answer: A (Determined by the trading area and navigational conditions, with more frequent checks in confined waters)
💡 The frequency of position checks should be determined by the risks of the area and the navigational conditions: longer intervals may be acceptable in open waters, while in confined waters, coastal passages and when entering port checks should be more frequent, such as at short intervals or at every alteration, ensuring deviations and dangers are detected in time.
✗
Question 38. What limitation must the officer of the watch bear in mind when using ARPA?
Your Answer: (Not answered)
Correct Answer: D (Target tracking may be lost or erroneous due to sea state, target manoeuvres or shadowing, so it cannot be relied upon entirely)
💡 ARPA tracking is affected by sea state, target manoeuvres, shadowing and input data accuracy, and targets may be lost or plotted in error. The officer must cross-check with the raw radar picture and visual look-out.
✗
Question 39. Into how many classes does the IMDG Code divide packaged dangerous goods?
Your Answer: (Not answered)
Correct Answer: D (Nine)
💡 The IMDG Code divides packaged dangerous goods into nine classes by hazard type, for example Class 1 explosives, Class 2 gases and Class 3 flammable liquids. The number is fixed at nine.
✗
Question 40. What are the core documents of the safety management system required by SOLAS Chapter IX?
Your Answer: (Not answered)
Correct Answer: A (A safety management manual together with supporting procedures covering the elements of the system)
💡 SOLAS IX and the ISM Code require a safety management manual with supporting procedures covering the elements of the Code. A policy statement or a single plan does not constitute a complete system.
✗
Question 41. What monitoring of the steering gear is required in normal operation?
Your Answer: (Not answered)
Correct Answer: C (Monitor noise, temperature, oil level and response, investigating any abnormality promptly)
💡 In service the steering gear should be monitored by abnormal noise, changes in oil temperature or level, slow response or increased steering effort, with any abnormality investigated promptly, such as leakage in the hydraulic system, deterioration of the oil or mechanical seizure, preventing loss of steering at sea.
✗
Question 42. What do SOLAS and good practice require of the electrical system after a fire?
Your Answer: (Not answered)
Correct Answer: A (Assess the circuits and equipment affected, isolate the faulty part and prioritise supply to emergency and firefighting equipment)
💡 After a fire the circuits affected should be assessed, the faulty part isolated and priority given to supplying emergency lighting, fire pumps and communications, preventing secondary incidents from short circuits or water. Cutting all power would defeat firefighting and evacuation.
✗
Question 43. How does the number of firefighter's outfits differ between tankers and ordinary cargo ships?
Your Answer: (Not answered)
Correct Answer: B (Tankers normally require four outfits, ordinary cargo ships two)
💡 SOLAS II-2/10.10 requires at least two firefighter's outfits on cargo ships of 1000 GT and above. Tankers must carry additional outfits, normally four in total, with extra breathing apparatus.
✗
Question 44. On what basis must rations in a lifeboat be provided under SOLAS III?
Your Answer: (Not answered)
Correct Answer: C (For the rated number of persons for the prescribed number of days, at the specified energy value per person)
💡 SOLAS III requires rations for the rated capacity for the prescribed number of days at a specified energy value per person, not for the actual complement and not for one day only.
✗
Question 45. What does SOLAS II-2 require regarding combustible materials in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: B (Surface materials and furnishings must be restricted in combustibility and comply with prescribed flame spread requirements)
💡 SOLAS II-2 limits the combustibility of bulkheads, ceilings, deck coverings and furniture in accommodation spaces, reducing fire load and the rate of spread.
✗
Question 46. A survey is carried out two months early. What is the effect under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (The next due date is still counted from the original anniversary, not postponed by the early survey)
💡 The SOLAS window allows flexibility in scheduling but does not change the due date, which is counted from the certificate anniversary. An early survey does not postpone the next one, preventing effective extension of the certificate by surveying early.
✗
Question 47. What safety precautions apply when using a CO2 extinguisher?
Your Answer: (Not answered)
Correct Answer: A (Hold the insulated handle to avoid cold burns and leave a poorly ventilated space promptly after use to avoid asphyxiation)
💡 CO2 discharges at a very low temperature, so the insulated handle should be held to avoid cold burns. CO2 displaces oxygen, so after heavy use in a confined space personnel should leave promptly and the space be ventilated, avoiding asphyxiation.
✗
Question 48. During the voyage the temperature records for a solid bulk cargo show a steady rise. What treatment of the matter is acceptable for the master?
Your Answer: (Not answered)
Correct Answer: C (testing made more frequent and the cause looked into, ventilation or sealing decided by what the cargo schedule requires, company and port informed)
💡 The Code prescribes different treatment by cargo: some self-heating materials want surface ventilation to carry heat off, others must have air restricted so the oxygen does not feed the reaction, and carbon dioxide is released in one dose to the designed concentration once the space is proved clear and tight. The basis is the proper name, the moisture and the trend, not the single clue of a rising thermometer; opening a hold can also bring smoke back over the working party. Closer record-keeping, report and measurement are the practical ship's side of it.
✗
Question 49. Which persons are not counted as passengers under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (Children under one year of age)
💡 Children under one year of age are not counted.
✗
Question 50. What do SOLAS and good practice require when radar and other radio equipment interfere with one another?
Your Answer: (Not answered)
Correct Answer: D (Identify the source and take measures such as adjusting antenna positions or settings so that all equipment works normally)
💡 Interference between equipment, such as same frequency radar or VHF and other transmitters, affects target presentation and communication. The cause should be found and removed by adjusting antenna positions, using filters or changing settings. Simply switching off the affected equipment is not acceptable.
✗
Question 51. Before boarding the lifeboat in an abandon ship drill, crew shall first:
Your Answer: (Not answered)
Correct Answer: D (Don lifejackets and act per the muster list)
💡 The drill covers alarm, mustering, donning lifejackets and operating the launching appliances per the muster list.
✗
Question 52. What does the weather criterion of the intact stability code examine?
Your Answer: (Not answered)
Correct Answer: B (a gust heeling lever added to that of the steady wind, the angle of heel and the downflooding angle retaining adequate margin)
💡 The criterion splits the wind into a steady pressure and a gust: the ship heels under the steady heeling lever and the gust pushes her further, the area under the righting lever curve having to exceed that under the wind levers, the gust heel staying within the fraction of the downflooding angle and inside the stated limit. Metacentric height or roll period alone cannot answer that question.
✗
Question 53. Why must fire nozzles be of the water-fog and jet dual-purpose type?
Your Answer: (Not answered)
Correct Answer: B (spray suiting oil and electrical fires and covering the approach, the jet reaching a distance and cooling the plating)
💡 One nozzle has to serve fires of quite different kinds. On a surface of burning oil, spray covers the fire, holds off the radiation and cools the compartment, whereas a solid jet breaks the oil about and spreads the fire with it; on electrical equipment and in live spaces spray is what may be used, and then only from the distance the practice allows. A water curtain also covers the party as they close on the seat of the fire. Yet to strike from a distance, or to cool a bulkhead or a cargo surface, a solid column is wanted, which is why the nozzle changes between the two without being swapped. Sparing fresh water and ease of carrying are not the point, and calling the jet a spare misreads what the fire demands.
✗
Question 54. Which factors must be considered in determining a safe speed under COLREG and SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Visibility, traffic density, manoeuvrability, background lights and weather conditions, among others)
💡 COLREG Rule 6 requires a safe speed to be determined with regard to visibility, traffic density, manoeuvrability, background lights and weather and sea state. Power or passage length alone is not a basis.
✗
Question 55. May AIS be switched off while the ship is under way? What is the position of SOLAS V?
Your Answer: (Not answered)
Correct Answer: A (AIS must remain in operation; it may be switched off only where the master considers this necessary for safety or security, with the reason recorded)
💡 SOLAS V/19.2.10 requires AIS to remain in operation, permitting it to be switched off only where the master believes its operation might compromise the safety or security of the ship, with the reasons entered in the log.
✗
Question 56. What overload protection is required for electrical equipment?
Your Answer: (Not answered)
Correct Answer: C (Overload protection for essential motors and cables, preventing overheating which damages insulation and causes fire)
💡 SOLAS requires overload protection for essential motors, cables and distribution equipment, operating to trip or alarm on overload, preventing prolonged overheating from ageing the insulation and causing an electrical fire, particularly in the high temperature environment of a machinery space.
✗
Question 57. What is required for the identification of valves in the bilge system?
Your Answer: (Not answered)
Correct Answer: B (Clear identification of function and direction of operation to prevent misoperation)
💡 SOLAS and good practice require valves in the bilge, ballast and fire systems to be clearly and durably identified as to function and direction of operation, so that in an emergency, particularly in poor visibility or under pressure, the crew does not open or close the wrong valve.
✗
Question 58. Portable fire extinguishers in machinery spaces shall be:
Your Answer: (Not answered)
Correct Answer: A (at least one near each hydrant and sufficient in total for the space)
💡 SOLAS II-2/10 requires at least one portable extinguisher near each hydrant, with sufficient total number.
✗
Question 59. Which watertight doors may be used for passage during navigation?
Your Answer: (Not answered)
Correct Answer: A (Sliding watertight doors)
💡 Sliding watertight doors may be used during navigation; other watertight doors shall be kept closed.
✗
Question 60. Which statement about fire hoses and hydrants complies with SOLAS?
Your Answer: (Not answered)
Correct Answer: D (The number of hoses must be sufficient to allow at least two jets of water to reach any part of the ship normally accessible)
💡 SOLAS requires enough hoses for at least two jets of water to reach any part of the ship normally accessible, with separate provisions for tankers and special spaces.
✗
Question 61. A ship is found without a permit system or gas testing procedure for entry into enclosed spaces. The finding is?
Your Answer: (Not answered)
Correct Answer: C (A permit and testing procedure for enclosed space entry is required; absence is a serious safety deficiency)
💡 Entry into enclosed spaces requires a permit system with testing for oxygen, flammable gas and toxic gas before entry, ventilation and an attendant, in accordance with procedures. The absence of a permit and testing procedure directly threatens the lives of those entering. It is a serious safety deficiency that may normally lead to detention.
✗
Question 62. The scrubber in an inert gas system mainly functions to:
Your Answer: (Not answered)
Correct Answer: C (cool and purify the inert gas, removing sulphur compounds and water)
💡 SOLAS II-2/5 requires a scrubber to cool and purify the inert gas, removing sulphur dioxide and moisture.
✗
Question 63. The security drills required by the ship security plan are found not held at the required intervals. The finding is?
Your Answer: (Not answered)
Correct Answer: A (Security drills should be held and recorded at the required intervals; failure is a security management deficiency)
💡 The ship security plan requires security drills to be held at regular intervals and recorded, keeping the crew familiar with security threats and emergency procedures. Failure to hold or record them shows the security measures are not being implemented properly. It is a deficiency to be corrected.
✗
Question 64. What do SOLAS and good practice address regarding testing the emergency source of power?
Your Answer: (Not answered)
Correct Answer: A (Periodic testing of automatic starting, change-over and the ability to carry load, with records kept)
💡 SOLAS and good practice require periodic testing of the automatic starting, change-over and load carrying capability of the emergency source, verifying that it can take up the emergency load as prescribed when the main source fails, with records kept for verification at survey.
✗
Question 65. What is required regarding the use of VHF in restricted visibility?
Your Answer: (Not answered)
Correct Answer: A (Broadcast one's position and movements to nearby vessels on VHF and listen to their reports to assist the appreciation)
💡 COLREG and good seamanship require broadcasting one's position, course, speed and intentions to nearby vessels on VHF, normally channel 16 or a locally designated channel, and listening to their reports. This is important to avoid collision in fog.
✗
Question 66. What is the most important preparation by the master for a PSC or SIRE inspection?
Your Answer: (Not answered)
Correct Answer: D (Ensuring the crew is familiar with the equipment and that records and the actual condition are genuine and complete)
💡 Preparation should focus on the true condition: operable equipment, genuine and complete records and a crew familiar with their duties. Filling in records at short notice or coaching answers will not survive an in-depth inspection and may amount to falsification.
✗
Question 67. Emergency lighting shall be capable of operating for at least:
Your Answer: (Not answered)
Correct Answer: B (18 hours)
💡 SOLAS II-1/42 requires the emergency source to provide emergency lighting for at least 18 hours.
✗
Question 68. A lifebuoy (liferaft) hydrostatic release unit is found beyond its specified service or renewal date. The finding is?
Your Answer: (Not answered)
Correct Answer: B (The overdue release unit prevents the liferaft from releasing automatically as required, a deficiency to be corrected)
💡 A hydrostatic release unit must be within its specified service life; beyond it reliability cannot be assured. If the ship sinks, a failed unit means the liferaft cannot float free automatically, directly endangering survival after abandonment. Any unit found overdue is recorded as a deficiency and must be replaced.
✗
Question 69. With regard to the stability of a grain-laden ship:
Your Answer: (Not answered)
Correct Answer: C (the effect of grain shift shall be considered and the Grain Code stability requirements met)
💡 SOLAS VI/6 requires consideration of grain shift and compliance with the International Grain Code stability requirements.
✗
Question 70. What does SOLAS Chapter XI-1 require of tankers and bulk carriers?
Your Answer: (Not answered)
Correct Answer: A (Enhanced surveys under the ESP)
💡 Enhanced surveys under the Enhanced Survey Programme.
✗
Question 71. Which account of the segregation of dangerous goods holds up?
Your Answer: (Not answered)
Correct Answer: A (keeping the goods apart as the IMDG Code requires, from other dangerous goods, from foodstuffs and from accommodation)
💡 Segregation pulls chemically unsuitable substances apart horizontally and vertically to the level the Code gives, so that a leak does not bring them into reaction, foul foodstuffs or reach accommodation; on the stowage plan that becomes the choice of hold and tier, the distance from heat and from living spaces, and the number each term - away from, separated from - calls for. It is not advice and two parties cannot agree it away: the levels already reckon the consequence of a leak, and an agreed change of position may only be made within what the level demands. One hold with two tiers commonly does not satisfy it, some combinations calling for a different hold or separation by a complete deck. The requirement belongs in the plan prepared before loading and is re-worked whenever the stow changes.
✗
Question 72. A cargo ship has lifeboats on one side and liferafts on the other. What is the basic requirement of SOLAS?
Your Answer: (Not answered)
Correct Answer: A (The survival craft capacity on each side must accommodate all persons on board)
💡 SOLAS requires that, whether lifeboats or liferafts are used, the capacity on each side accommodates all persons on board, so everyone can escape if one side is unavailable.
✗
Question 73. What should be done if a watertight door cannot be closed after damage?
Your Answer: (Not answered)
Correct Answer: A (Take measures to plug or otherwise limit the flooding, assess stability and decide the further course of action)
💡 A watertight door that cannot be closed allows flooding to spread. Measures to plug it, such as with leak-stopping material or wedges, or to limit the flooding should be taken at once, the stability and rate of flooding assessed and the further course decided, whether to beach, pump out or seek outside assistance, with the company informed.
✗
Question 74. Survival craft shall be capable of rapid launching:
Your Answer: (Not answered)
Correct Answer: B (under unfavourable conditions of trim and list)
💡 SOLAS III/16 requires rapid launching under unfavourable conditions of trim and list.
✗
Question 75. What does the ISM Code require regarding maintenance of the ship and equipment?
Your Answer: (Not answered)
Correct Answer: A (The company must establish maintenance arrangements with inspections and servicing of critical equipment at the prescribed intervals, recorded)
💡 ISM Code 10 requires the company to establish planned maintenance arrangements, inspecting and servicing critical equipment at the prescribed intervals with records kept, preventing failures from lack of maintenance. Breakdown repair alone does not comply.
✗
Question 76. Magnetic compasses shall:
Your Answer: (Not answered)
Correct Answer: B (be adjusted periodically and a table of residual deviations provided)
💡 SOLAS V/19 requires periodic adjustment of magnetic compasses and a table of residual deviations.
✗
Question 77. What does SOLAS require of the water ingress detection and alarm system on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: B (Detection in cargo holds, ballast tanks and dry spaces, with an audible and visual alarm on the bridge)
💡 SOLAS XII/12 requires a bulk carrier to have water ingress detection in cargo holds, ballast tanks and dry spaces, with an audible and visual alarm on the bridge, enabling the watchkeeper to detect flooding promptly and act.
✗
Question 78. What is required if a particular drill cannot be held in a month?
Your Answer: (Not answered)
Correct Answer: B (It should be held as soon as conditions permit, normally within 24 hours, with the reason for the delay recorded in the log)
💡 SOLAS requires a drill not held in a month because of navigational conditions to be held as soon as conditions permit, normally within the following 24 hours, with the reason for the delay recorded in the deck log. Missing drills over several months is a serious deficiency.
✗
Question 79. What determines the type of protection required for electrical equipment in a hazardous area?
Your Answer: (Not answered)
Correct Answer: C (Whether the type of equipment matches the hazard level of the area, such as the zone classification for explosive gas atmospheres)
💡 SOLAS and the IEC standards prescribe the types of protection permitted according to the zone classification of the hazardous area, such as zones 0, 1 and 2. The equipment type must match the area, or it may become a source of ignition.
✗
Question 80. What preparations should a ship make before an annual survey?
Your Answer: (Not answered)
Correct Answer: A (Keep equipment in good order and have records, certificates and survey reports ready so that the survey proceeds smoothly)
💡 Before a survey, equipment should be in working order, records and certificates available, routine maintenance completed and known problems dealt with, avoiding deficiencies, or even an effect on the validity of certificates, from equipment not working or records missing.
✗
Question 81. What is the usual maximum validity of a Cargo Ship Safety Radio Certificate?
Your Answer: (Not answered)
Correct Answer: B (Five years, with periodical surveys)
💡 Under SOLAS I/12 the Cargo Ship Safety Radio Certificate has a usual validity of not more than five years, with periodical surveys as required. The performance and provision of the radio installation, including distress alerting, communications and the reserve source of energy, are the focus of the survey.
✗
Question 82. A PSC inspection checked the enhanced survey documentation of a tanker. What document does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (A survey programme identifying the scope of close-up survey and thickness measurement)
💡 The ESP requires the ship to hold a survey programme specifying the extent of close-up survey and thickness measurement, agreed by the class society and the owner. A survey or thickness report alone does not evidence the existence and execution of the programme.
✗
Question 83. What are the operating requirements for a lifejacket light?
Your Answer: (Not answered)
Correct Answer: A (It must operate automatically and last at least the prescribed period, normally eight hours or more)
💡 The light fitted to a lifejacket must operate automatically in water and last for at least the prescribed period, normally eight hours, so that persons can be seen at night. Manual operation or an ordinary torch is not acceptable.
✗
Question 84. In what form must the safe working load information for mooring equipment be kept under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (On board in an accessible form identifying each fitting and its safe working load)
💡 SOLAS requires information on the arrangement, identification and safe working load of mooring and towing equipment to be kept on board, such as a mooring arrangement plan and load table, for correct use and inspection.
✗
Question 85. Before departure the master shall ensure that:
Your Answer: (Not answered)
Correct Answer: D (the ship's stability and trim are satisfactory)
💡 SOLAS II-1/5 requires the master to verify stability and trim before departure.
✗
Question 86. With regard to navigational warnings and notices, which statement is correct?
Your Answer: (Not answered)
Correct Answer: A (The ship must be able to receive them and act on them)
💡 SOLAS V/28: the ship must be able to receive and act on navigational warnings and notices.
✗
Question 87. What does the Polar Code address regarding emergency preparedness in polar waters?
Your Answer: (Not answered)
Correct Answer: A (Recognise the long distances and response times and strengthen self-help capability and emergency supplies)
💡 The Polar Code requires recognition that search and rescue resources in polar regions are limited, response times long and weather conditions severe, so the ship must strengthen her self-help capability, carry ample emergency supplies such as food, thermal protection and fuel and have suitable emergency procedures.
✗
Question 88. To which tankers does the emergency towing arrangement requirement of SOLAS II-1/3-3 apply?
Your Answer: (Not answered)
Correct Answer: D (Oil tankers of 20000 tonnes deadweight and above)
💡 SOLAS II-1/3-3 requires oil tankers of 20000 tonnes deadweight and above to be fitted with an emergency towing arrangement at bow and stern, so that a disabled tanker can be taken in tow. It is not limited to new ships.
✗
Question 89. A section of the fire detection system fails to alarm during testing. What should be done?
Your Answer: (Not answered)
Correct Answer: C (Establish the cause at once, such as a failed detector, broken wiring or incorrect zoning, and repair it)
💡 A section that does not alarm means a fire there would not be detected in time. The cause must be established at once, whether a failed detector, broken wiring, incorrect zoning or an inhibited circuit, and repaired. Disabling the section or relying on another leaves a serious latent hazard.
✗
Question 90. In a bridge design review for a new multi-purpose vessel the yard submits four statements: (1) five forward windows with frames kept as narrow as practicable; (2) a refrigeration compressor casing at the conning position blocking about 15 degrees ahead; (3) in ballast the sea surface ahead of the bow is not visible from the conning position; (4) fixed wipers with washing and defrosting on the forward windows. Which statements are non-compliant with SOLAS chapter V?
Your Answer: (Not answered)
Correct Answer: D (items 2 and 3)
💡 The permitted blind sector forward of the conning position is limited, so a 15-degree obstruction ahead is a classic layout error, and the field must be met in both loaded and ballast conditions — a bare claim that the bow can be seen is not enough. Narrow frames, fixed wipers and wash/defrost are what V/22 expects, so 1 and 4 comply.
✗
Question 91. A bypass pipe allowing oily water to be discharged overboard while circumventing the oily water separator is found on board. The finding is?
Your Answer: (Not answered)
Correct Answer: C (An illegal bypass is a serious violation that may lead to detention and administrative penalty)
💡 Oily water must be processed and meet the discharge standard before discharge. Fitting a bypass pipe to discharge overboard while circumventing the separator is a serious violation evading pollution prevention rules. Once found it is not only a detainable deficiency but may also trigger administrative penalty and investigation.
✗
Question 92. What does the steering gear test before departure include under SOLAS and good seamanship?
Your Answer: (Not answered)
Correct Answer: C (Testing the main and auxiliary steering gear, checking the rudder angle indicator, and verifying bridge to steering gear compartment communication and the emergency steering procedure)
💡 Before departure the main and auxiliary steering gear should be tested, the rudder angle indicator checked, and communication with the steering gear compartment and the emergency steering procedure verified. Failure of any item may have serious consequences in a narrow channel or when berthing.
✗
Question 93. What is required when using AIS safety related messages?
Your Answer: (Not answered)
Correct Answer: C (AIS safety related messages may inform other vessels of the ship's status but must not replace the prescribed distress alerting means)
💡 AIS safety related messages, such as not under command, restricted in ability to manoeuvre or in distress, may be used to inform surrounding vessels, but they must not replace the prescribed means of distress alerting, DSC, radiotelephony, satellite or EPIRB. AIS is supplementary only.
✗
Question 94. What is the scope of the term 'ship' in SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Any ship engaged on international voyages, with exclusions such as warships and some small cargo ships)
💡 SOLAS applies to ships on international voyages, with stated exclusions for warships and certain small cargo ships.
✗
Question 95. What segregation is required between dangerous goods and foodstuffs?
Your Answer: (Not answered)
Correct Answer: D (Toxic or contaminating dangerous goods must be segregated from foodstuffs as the IMDG Code requires, preventing contamination)
💡 The IMDG Code requires class 6 toxic substances and materials liable to contaminate foodstuffs to be segregated from food cargoes as prescribed, normally in different holds or separated by a complete bulkhead, preventing leakage from contaminating food and poisoning persons. Stowing them adjacent on the ground that the packages are sound does not comply.
✗
Question 96. After failure of the main source of power, within what period must the emergency generator take over automatically?
Your Answer: (Not answered)
Correct Answer: A (Within 45 seconds)
💡 SOLAS II-1/41 requires the emergency generator to start automatically and connect to the emergency switchboard within 45 seconds. Fifteen seconds applies to the transitional reserve source of power (batteries).
✗
Question 97. Double bottom spaces may be used:
Your Answer: (Not answered)
Correct Answer: B (as ballast or fuel oil tanks, subject to restrictions on fuel oil tank location)
💡 SOLAS II-1/9 permits double bottom spaces to be used for ballast or fuel, subject to restrictions on fuel oil tanks.
✗
Question 98. What fixed fire-extinguishing system must be fitted in the cargo tank deck area of a tanker?
Your Answer: (Not answered)
Correct Answer: C (A fixed deck foam system)
💡 SOLAS II-2/10.5 requires tankers to be provided with a fixed deck foam system for the cargo tank deck area.
✗
Question 99. What does the ISM Code require regarding training of personnel on board?
Your Answer: (Not answered)
Correct Answer: C (Crew must be trained and have the knowledge and skills needed for their duties, with records kept)
💡 ISM Code 6 requires the company to establish training procedures ensuring that personnel are trained and have the knowledge and skills needed for their duties, with records kept. Training must be completed before taking up duties, not afterwards.
✗
Question 100. What document may be concluded between a ship and a port facility when security responsibilities are shared?
Your Answer: (Not answered)
Correct Answer: B (A Declaration of Security)
💡 Part A of the ISPS Code provides that a Declaration of Security may be concluded between ship and port facility, setting out the security measures and responsibilities of each during the interface. It is not a cargo or transport document.