Question 1. Where must the water ingress alarm of a bulk carrier be displayed?
Your Answer: (Not answered)
Correct Answer: B (On the navigation bridge, so the watchkeeper learns at once of flooding in a hold)
💡 SOLAS XII/12 requires the water ingress detection alarm of a bulk carrier to be displayed on the bridge so the officer of the watch can identify the flooded hold and act immediately. Display elsewhere delays response.
✗
Question 2. What must be verified about the righting lever curve after loading?
Your Answer: (Not answered)
Correct Answer: B (That the positive range of the curve and the maximum righting lever meet the criteria)
💡 The intact stability criteria require the righting lever at specified angles, such as 30 or 40 degrees, the maximum righting lever and its angle and the positive range of the curve all to meet the requirements. The initial metacentric height alone does not show stability at large angles of heel.
✗
Question 3. Why does SOLAS require firefighter's outfits to be stowed in more than one location?
Your Answer: (Not answered)
Correct Answer: A (To prevent a fire in one place from making all the outfits unavailable, so they are distributed)
💡 SOLAS requires firefighter's outfits to be stowed in two or more positions because, if they were all in one place, a fire there would make every outfit unavailable and firefighting and rescue could not proceed.
✗
Question 4. What are the security measures at security level 1?
Your Answer: (Not answered)
Correct Answer: B (The minimum protective measures maintained at all times in normal conditions, such as controlling access and monitoring restricted areas)
💡 ISPS Code Part A/12 requires security level 1 to be maintained continuously, including control of access to the ship, monitoring of restricted areas and supervision of persons and cargo embarking. These are the basic measures in normal operation.
✗
Question 5. When navigating in polar waters, what should be paid particular attention to under the Polar Code?
Your Answer: (Not answered)
Correct Answer: A (The effects of low temperature on equipment and personnel, ice conditions and ice class, and the procedures and limitations in the Polar Ship's Operational Manual)
💡 The polar environment is special, so particular attention should be paid to the effects of low temperature on equipment such as life-saving appliances, firefighting, fuel and hydraulic systems and on personnel, to ice conditions and the ship's ice class limits, and to the operational procedures and limitations in the Polar Ship's Operational Manual, with specific training and preparation carried out.
✗
Question 6. After failure of the main source of power, within what period must the emergency generator take over automatically?
Your Answer: (Not answered)
Correct Answer: A (Within 45 seconds)
💡 SOLAS II-1/41 requires the emergency generator to start automatically and connect to the emergency switchboard within 45 seconds. Fifteen seconds applies to the transitional reserve source of power (batteries).
✗
Question 7. What is required for checking the tightness of hatch covers on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Periodic inspection of seals, cleats and drain channels with a hose test to verify weathertightness)
💡 SOLAS requires the hatch covers of a bulk carrier to remain weathertight, with periodic checks of seal ageing, the effectiveness of cleats and the clearance of drain channels, and a hose test where necessary to verify tightness, preventing sea water from entering the holds and damaging structure and cargo.
✗
Question 8. On what band does a SART operate?
Your Answer: (Not answered)
Correct Answer: C (9 GHz (X band))
💡 It operates on 9 GHz (X band) so as to be detected by radar.
✗
Question 9. What does SOLAS III require for markings and instructions on life-saving appliances?
Your Answer: (Not answered)
Correct Answer: C (They must be clearly marked in the working language of the ship or in English, with operating illustrations)
💡 SOLAS III requires markings, instructions and operating illustrations to be clearly given in the working language of the ship or in English so that all crew members can understand them.
✗
Question 10. Each lifeboat shall be provided with equipment including:
Your Answer: (Not answered)
Correct Answer: B (a complete set including oars, compass, sea anchor, first-aid kit, etc.)
💡 SOLAS III/34 lists lifeboat equipment including oars, compass, sea anchor, first-aid kit, food and water.
✗
Question 11. What do SOLAS and the ISM Code require in the execution of the planned maintenance programme?
Your Answer: (Not answered)
Correct Answer: B (Carry out the programme and record completion, with reasons given and re-scheduling for items not completed)
💡 ISM Code 10 requires the planned maintenance programme to be carried out with completion and any problems found recorded. Items not completed should have the reason stated, the risk assessed and the work re-scheduled, keeping equipment in good order at all times.
✗
Question 12. How is continual improvement of the safety management system demonstrated?
Your Answer: (Not answered)
Correct Answer: A (Through a cycle of setting objectives, monitoring performance, identifying problems at audit and taking improvement action)
💡 Continual improvement is achieved through a cycle of setting safety and pollution prevention objectives, monitoring performance such as accident rates, non-conformities and deficiency numbers, identifying problems through audit and review and taking corrective and preventive action, so that the system is continuously refined rather than being fixed once established.
✗
Question 13. What is required for monitoring and re-entry after releasing a fixed extinguishing system?
Your Answer: (Not answered)
Correct Answer: C (Monitor the boundary temperature of the space to judge the fire, and enter only after cooling, adequate ventilation and satisfactory testing)
💡 After releasing a fixed extinguishing system the boundary temperature of the space should be monitored to judge whether the fire is out and the space kept closed for a sufficient period. Entry is permitted only after the boundary temperature has clearly fallen, adequate ventilation has been carried out and oxygen and harmful gas tests are satisfactory, with breathing apparatus worn.
✗
Question 14. What does SOLAS require regarding a look-out when the ship is under way?
Your Answer: (Not answered)
Correct Answer: A (A look-out must be posted when conditions require it, to assist the officer in maintaining a proper look-out)
💡 SOLAS and COLREG require a look-out to be posted when conditions demand it, such as in restricted visibility, dense traffic or narrow channels. The look-out's sole duty is to keep watch and report, without other tasks such as steering.
✗
Question 15. When a pilot is on board, how is responsibility allocated?
Your Answer: (Not answered)
Correct Answer: A (The pilot provides pilotage and advice but does not relieve the master of responsibility for the safety of the ship)
💡 A pilot on board provides local pilotage and manoeuvring advice but does not relieve the master of responsibility for the safety of the ship. The master and officer of the watch should still monitor the ship's movement and, if the pilot's orders are likely to cause danger, should speak up promptly and take necessary action.
✗
Question 16. While underway the ship receives word from her Administration that the security level has been raised, while the terminal remains at the former level. What applies on board?
Your Answer: (Not answered)
Correct Answer: A (the notified level being implemented with the master's instructions, co-ordinated with the port facility security officer, the facility's own level not reducing the ship's duty)
💡 Levels are set for the ship by her Administration and for the facility by the Contracting Government; on notice of an increase the ship implements the additional measures of her plan for that level, informs the master, crew and the facility concerned, and settles any mismatch by co-ordination. The terminal staying at the lower level does not reduce the ship's duty, and relaxing the ship to match it is not the answer.
✗
Question 17. A cargo ship has lifeboats on one side and liferafts on the other. What is the basic requirement of SOLAS?
Your Answer: (Not answered)
Correct Answer: A (The survival craft capacity on each side must accommodate all persons on board)
💡 SOLAS requires that, whether lifeboats or liferafts are used, the capacity on each side accommodates all persons on board, so everyone can escape if one side is unavailable.
✗
Question 18. What information shall the shipper provide to the master before loading solid bulk cargoes?
Your Answer: (Not answered)
Correct Answer: A (Physical and chemical properties including moisture content)
💡 SOLAS XII/6: the shipper shall provide properties such as density, moisture content and flow moisture point.
✗
Question 19. What emergency supplies are required in polar waters?
Your Answer: (Not answered)
Correct Answer: D (Sufficient warm clothing, emergency food and water, heating means and emergency lighting)
💡 The Polar Code requires emergency supplies suited to the polar environment: ample warm clothing and thermal protection, emergency food and water, means of heating such as a spare heater, emergency lighting and communication equipment, in view of the long search and rescue response times.
✗
Question 20. What is the requirement for the international shore connection?
Your Answer: (Not answered)
Correct Answer: B (At least one must be carried on board with gasket, bolts and other fittings)
💡 SOLAS II-2/19 requires at least one standard international shore connection with fittings to be carried on board so that water can be supplied from shore or another ship. The ship cannot rely on the port providing it.
✗
Question 21. What steering gear checks should be made before navigating in confined waters?
Your Answer: (Not answered)
Correct Answer: C (Check the steering gear alarms, test rudder movement and the rudder angle indicator and confirm the power and control systems are in order)
💡 Before navigating in confined waters such as a narrow channel or when berthing, the steering gear should be tested, the rudder angle indicator checked and the alarms and the power and control systems verified. A sudden steering failure in confined waters has serious consequences.
✗
Question 22. What does SOLAS V require regarding danger messages?
Your Answer: (Not answered)
Correct Answer: A (A danger message must be sent immediately on encountering a danger to navigation, with notification to the competent authority)
💡 SOLAS V/31 requires the master to send a danger message immediately on encountering a danger such as floating objects, uncharted obstructions or severe ice, and to notify the competent authority so warnings can be issued.
✗
Question 23. How many lifebuoys must be fitted with self-igniting lights under SOLAS III/7.1?
Your Answer: (Not answered)
Correct Answer: A (Not less than one half of the total number of lifebuoys)
💡 SOLAS III/7.1 requires not less than one half of the total lifebuoys to be fitted with self-igniting lights. The requirement for buoyant lifelines is a separate provision.
✗
Question 24. Under GMDSS, what standing watches must the ship keep for distress and safety communications?
Your Answer: (Not answered)
Correct Answer: B (the watches the ship's fit requires — DSC on the distress and safety frequencies and reception of safety broadcasts, with a listening watch on VHF channel 16)
💡 The point of the watches is that another ship's alert and the shore's safety broadcasts reach the bridge: DSC on the designated distress and safety frequencies at MF/HF, maritime safety information by NAVTEX or the satellite EGC service, and a listening watch on VHF channel 16 under way, with someone answerable for alarms, printed receipts and updates. No exemption arises from being in port, from rest hours or from trading in one area, and the duty cannot be handed to the shore, which cannot know when this ship needs the message.
✗
Question 25. Which of the following are common types of fixed fire detection systems?
Your Answer: (Not answered)
Correct Answer: A (Smoke, heat and flame (radiation) detectors)
💡 SOLAS recognises fixed detection systems including smoke, heat and flame (radiation) types, selected according to the nature of the space and the fire characteristics expected.
✗
Question 26. What is the minimum number of firefighter's outfits for a cargo ship?
Your Answer: (Not answered)
Correct Answer: A (At least two)
💡 Under SOLAS II-2/10 a cargo ship should carry at least two firefighter's outfits, comprising protective clothing, boots, gloves, a rigid helmet, a safety lamp and an axe, with tankers requiring more as specified. Insufficient provision weakens the ability to enter a fire area.
✗
Question 27. Below which value shall the inert gas system maintain the oxygen content in cargo tanks?
Your Answer: (Not answered)
Correct Answer: A (8% by volume)
💡 SOLAS requires the oxygen content to be maintained at not more than 8% by volume.
✗
Question 28. The main steering gear shall be capable, at maximum ahead service speed, of:
Your Answer: (Not answered)
Correct Answer: B (completing the full rudder movement within the prescribed time)
💡 SOLAS II-1/29 requires the main steering gear to complete the 35°-to-35° movement within the prescribed time at maximum ahead service speed.
✗
Question 29. On the night watch the OOW must keep track of every watertight door. Under SOLAS chapter II-1, which requirement for power-operated sliding watertight doors is stated correctly?
Your Answer: (Not answered)
Correct Answer: A (the bridge shall carry indicators showing each door open or closed, closing normally taking between 20 and 40 seconds with the alarm sounding throughout)
💡 Bridge indicators showing each door individually exist so the OOW can confirm watertight integrity at any moment, not only after flooding; the 20-40 second closing time and continuous alarm give persons below the door time to clear. Verbal relaying or control-room-only indication is a substitute the regulation does not accept.
✗
Question 30. What is the role of the bulkhead deck in subdivision?
Your Answer: (Not answered)
Correct Answer: A (It is the deck to which the main watertight bulkheads extend upward from the bottom)
💡 The bulkhead deck is the uppermost deck to which the main watertight bulkheads extend, forming the basis for subdivision and damage stability calculations.
✗
Question 31. The quantity of extinguishing medium stored for a fixed gas fire-extinguishing system shall be sufficient for:
Your Answer: (Not answered)
Correct Answer: B (the volume of the largest protected space)
💡 SOLAS II-2/10 requires the stored quantity of medium to be sufficient for the largest protected space.
✗
Question 32. What are the stowage and testing requirements for the emergency towing arrangement?
Your Answer: (Not answered)
Correct Answer: C (Stowed so as to be readily available and inspected at regular intervals)
💡 SOLAS requires the emergency towing arrangement to be stowed where it can be rapidly deployed and to be inspected regularly, so that it works in an emergency. Long-term stowage in a hold or neglect of inspection may delay assistance.
✗
Question 33. A door in an escape route is found locked. What should be done?
Your Answer: (Not answered)
Correct Answer: C (Unlock it at once; doors in escape routes must be openable from inside without a key)
💡 A locked door in an escape route prevents evacuation in an emergency. SOLAS requires such doors to be openable from inside without a key. Security concerns should be met by other means such as an alarm, not by obstructing escape.
✗
Question 34. A pressure test found insufficient pressure when two jets were played simultaneously. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: A (Fire pumps must maintain the prescribed pressure and jets when the required number of hydrants are in simultaneous use)
💡 SOLAS II-2 requires the fire pumps to maintain the prescribed pressure and reach of the jets with the required number of hydrants in simultaneous use. Insufficient pressure impairs firefighting and is a deficiency.
✗
Question 35. Under typical conditions (antenna height and SART height of 1 m), a SART should be detectable at a range of about:
Your Answer: (Not answered)
Correct Answer: D (5 nm)
💡 SOLAS IV/7: a SART should be detectable at a range of about 5 nautical miles under typical conditions.
✗
Question 36. What is the correct radiotelephony distress procedure?
Your Answer: (Not answered)
Correct Answer: A (Say MAYDAY three times, then give the ship's name, position and nature of distress and wait for an answer)
💡 The distress call comprises MAYDAY three times, followed by the name and call sign of the ship, her position, the nature of the distress and the assistance required, then waiting for an answer. Channel 70 must not be used for speech.
✗
Question 37. What must the VDR record?
Your Answer: (Not answered)
Correct Answer: B (Position, course, speed, radar images, bridge audio and alarms)
💡 SOLAS requires the VDR to record data relevant to investigation, including date and time, position, course, speed, radar images with AIS, bridge audio, alarms and rudder orders, enabling the navigation and operation at the time to be reconstructed.
✗
Question 38. What does the IMSBC Code require when loading high density cargo into a bulk carrier?
Your Answer: (Not answered)
Correct Answer: C (Control of the weight in each hold, the sequence of loading and the differences between adjacent holds, avoiding excessive local stress and deformation)
💡 The IMSBC Code and SOLAS require strict control of the weight in each hold, the sequence and the differences between adjacent holds when loading high density cargo, preventing excessive local stress on the tank top and hull, which could cause permanent deformation or failure.
✗
Question 39. What is required regarding alcohol and watchkeeping?
Your Answer: (Not answered)
Correct Answer: A (Crew must not be under the influence of alcohol before or during a watch, with the effect of alcohol managed)
💡 STCW and the MLC prohibit a crew member from being under the influence of alcohol before or during a watch, and the company should have a policy with limits and testing requirements and take action against breaches. Alcohol seriously impairs judgement and reaction and is a major safety hazard.
✗
Question 40. What do GMDSS procedures require regarding relaying a distress alert?
Your Answer: (Not answered)
Correct Answer: A (Where the casualty cannot establish communication or the alert has not been acknowledged, a ship receiving it must relay the alert)
💡 GMDSS procedures require a ship receiving a distress alert to relay it where a coast station has not acknowledged it, the casualty cannot establish reliable communication, or relaying would help. The alert must reach the search and rescue service.
✗
Question 41. Which types of emergency source of power does SOLAS permit?
Your Answer: (Not answered)
Correct Answer: A (An emergency generator or a battery, supplying the emergency services for the prescribed period)
💡 SOLAS permits the emergency source to be an emergency generator or a battery. Where a battery is used its capacity must carry the emergency services, such as emergency lighting, communications and alarms, for the prescribed period.
✗
Question 42. What launching methods are acceptable for survival craft?
Your Answer: (Not answered)
Correct Answer: C (Davit, free-fall or others appropriate to the type, all ensuring safety)
💡 Methods appropriate to the type, such as davit or free-fall, are acceptable.
✗
Question 43. Under the ISM Code, accidents and hazardous occurrences shall be:
Your Answer: (Not answered)
Correct Answer: D (reported, investigated and analysed)
💡 SOLAS IX/9 (ISM) requires all accidents and hazardous occurrences to be reported, investigated and analysed.
✗
Question 44. What safety is required in spaces adjacent to a hold containing cargo that may release harmful gas?
Your Answer: (Not answered)
Correct Answer: B (Monitor gas concentrations in adjacent spaces such as enclosed passages and stores, preventing gas ingress)
💡 For cargoes that may release harmful or flammable gas, the IMSBC Code requires monitoring not only inside the hold but also the possibility of gas entering adjacent enclosed spaces such as passages, stores and the machinery space through bulkheads, piping and access ways, preventing poisoning or the ignition of the gas.
✗
Question 45. The muster list is found not updated after crew changes and some duties are vacant. The finding is?
Your Answer: (Not answered)
Correct Answer: A (The muster list must match the crew on board; failure to update is an emergency preparedness deficiency)
💡 The muster list should set out the duties and muster station of each crew member in an emergency and be updated promptly with crew changes so that everyone knows their duty. Failure to update leaves some posts vacant and causes confusion in an emergency. It is a deficiency to be corrected.
✗
Question 46. Which statement about cooperation with a marine casualty investigation is correct?
Your Answer: (Not answered)
Correct Answer: C (Provide information truthfully, preserve the scene and evidence and cooperate, without falsifying or concealing)
💡 In a marine casualty investigation the ship should provide information truthfully, preserve the scene and evidence such as VDR data, the official log book, bell and engine movement records and pollution samples, and cooperate. Falsifying, concealing or destroying evidence is a serious violation with legal consequences.
✗
Question 47. The self-contained breathing apparatus in a firefighter's outfit shall be capable of being used for at least:
Your Answer: (Not answered)
Correct Answer: C (30 minutes)
💡 SOLAS II-2/10: the self-contained breathing apparatus in a firefighter's outfit shall be capable of being used for at least 30 minutes.
✗
Question 48. Which ships shall be fitted with a BNWAS?
Your Answer: (Not answered)
Correct Answer: A (all passenger ships and cargo ships of 500 GT and above)
💡 SOLAS V/19: all passenger ships and cargo ships of 500 GT and above shall be fitted with a BNWAS.
✗
Question 49. Where must the remote controls of quick closing valves be located?
Your Answer: (Not answered)
Correct Answer: C (Outside the machinery space in an accessible position, clearly marked)
💡 SOLAS requires the remote controls of quick closing valves to be located outside the machinery space in a readily accessible and clearly marked position, so fuel can be shut off even if the space is on fire and cannot be entered.
✗
Question 50. What is the fresh water requirement in a lifeboat under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (Not less than 3 litres for each person of the rated capacity, with the prescribed drinking vessel for each person)
💡 SOLAS requires not less than 3 litres of fresh water for each person of the rated capacity, with the prescribed drinking vessel for each person. Insufficient water seriously reduces survival time after abandonment.
✗
Question 51. The master shall report:
Your Answer: (Not answered)
Correct Answer: C (dangerous conditions such as ice, derelicts or other hazards to navigation)
💡 SOLAS V/31 requires the master to report dangerous conditions such as ice, derelicts or other hazards.
✗
Question 52. What does the Polar Code address regarding emergency preparedness in polar waters?
Your Answer: (Not answered)
Correct Answer: A (Recognise the long distances and response times and strengthen self-help capability and emergency supplies)
💡 The Polar Code requires recognition that search and rescue resources in polar regions are limited, response times long and weather conditions severe, so the ship must strengthen her self-help capability, carry ample emergency supplies such as food, thermal protection and fuel and have suitable emergency procedures.
✗
Question 53. What principle should the officer of the watch follow in using ECDIS in confined waters or a port approach?
Your Answer: (Not answered)
Correct Answer: B (Adjust the display scale appropriately and keep the chart updated, avoiding over-reliance on a single display for position)
💡 ECDIS should be used with the scale adjusted to the leg of the passage, charts kept updated and the position cross-checked. Switching off safety alarms or fixing one scale weakens the warning function and increases the risk of grounding.
✗
Question 54. What medical care is required on board?
Your Answer: (Not answered)
Correct Answer: A (Prescribed medicines and medical equipment, access to medical guides and personnel trained in first aid)
💡 SOLAS and the MLC require a ship to carry the prescribed medicines and medical equipment, determined by the trading area and the number of crew, to keep the International Medical Guide for Ships and access to medical advice available and to have crew trained in first aid and medical care, so that basic treatment can be given on board.
✗
Question 55. The voyage plan shall be monitored by:
Your Answer: (Not answered)
Correct Answer: A (the master overall, with the officer of the watch executing and monitoring it)
💡 SOLAS V/34 requires the master to be responsible and the OOW to execute and monitor the voyage plan.
✗
Question 56. A B-15 class division means a B class division capable of withstanding a standard fire test for:
Your Answer: (Not answered)
Correct Answer: A (15 minutes)
💡 SOLAS II-2/3: a B-15 class division is a B class division capable of withstanding a standard fire test for 15 minutes.
✗
Question 57. What is required for the batteries of two-way VHF radiotelephones in survival craft?
Your Answer: (Not answered)
Correct Answer: D (Capacity meeting the required operating time, with periodic testing and replacement)
💡 SOLAS requires the batteries of two-way VHF sets to have capacity for the prescribed operating time, with periodic testing and replacement. Neglecting this means the equipment may not work on abandonment.
✗
Question 58. What is the usual maximum validity of a Cargo Ship Safety Equipment Certificate?
Your Answer: (Not answered)
Correct Answer: D (Five years, with annual and periodical surveys)
💡 Under SOLAS I/12 the Cargo Ship Safety Equipment Certificate has a usual validity of not more than five years, with annual and periodical surveys within it. It remains valid only if the surveys are carried out and endorsed, the safety equipment provision and performance being the focus of the survey.
✗
Question 59. Which spaces must emergency lighting cover at a minimum under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (Embarkation stations, survival craft stowage positions, escape routes, machinery spaces and the bridge, among other essential spaces)
💡 SOLAS requires emergency lighting for essential spaces including embarkation stations, survival craft stowage positions, escape routes, machinery spaces, the bridge and fire control stations, supporting abandonment and emergency operations.
✗
Question 60. What must be done with the system documentation when a ship changes management company or owner?
Your Answer: (Not answered)
Correct Answer: A (Documentation consistent with the new company's system must be established with the corresponding audit and certification)
💡 When the management company or owner changes, the safety management system must be re-established on the basis of the new company's documentation, with the ship's procedures revised as necessary, and internal and Administration audits completed to obtain or reissue the DOC and SMC. Continuing with the previous company's documentation does not comply.
✗
Question 61. What does SOLAS require for emergency communication between the bridge and the machinery space?
Your Answer: (Not answered)
Correct Answer: A (Means independent of the main communication system, such as the telegraph or an independent telephone)
💡 SOLAS requires an independent means of emergency communication between the bridge and machinery space, so that manoeuvring orders can still be passed if the main system fails. A hand-held radio is not an acceptable compliant means.
✗
Question 62. The emergency fire pump needs manual priming before it will draw water. What does SOLAS address?
Your Answer: (Not answered)
Correct Answer: B (A deficiency; the emergency fire pump must draw water by itself, and manual priming would delay emergency use)
💡 SOLAS requires the emergency fire pump to be self-priming, or to have a priming arrangement meeting the requirements, so that it draws water without manual priming in an emergency. Needing manual priming would delay the water supply when it matters and is a deficiency.
✗
Question 63. What length must a rescue boat have under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Not less than 3.8 m and not more than 8.5 m)
💡 SOLAS requires a rescue boat to be not less than 3.8 m and not more than 8.5 m in length, balancing carrying capability against the ability to be manoeuvred and recovered quickly. Too small gives insufficient capacity, too large hinders rapid handling.
✗
Question 64. With regard to manoeuvring indications on the bridge:
Your Answer: (Not answered)
Correct Answer: A (propeller speed and direction of rotation shall be indicated on the bridge)
💡 SOLAS V/19 requires propeller speed and direction of rotation to be indicated on the bridge.
✗
Question 65. What does SOLAS require regarding the marking of the rated capacity of survival craft?
Your Answer: (Not answered)
Correct Answer: B (It must be clearly marked on the craft and must not be exceeded)
💡 SOLAS requires the rated capacity to be clearly marked on the craft and not to be exceeded. Overloading seriously affects buoyancy and stability.
✗
Question 66. What document may be concluded between a ship and a port facility when security responsibilities are shared?
Your Answer: (Not answered)
Correct Answer: B (A Declaration of Security)
💡 Part A of the ISPS Code provides that a Declaration of Security may be concluded between ship and port facility, setting out the security measures and responsibilities of each during the interface. It is not a cargo or transport document.
✗
Question 67. What emergency supplies must be carried?
Your Answer: (Not answered)
Correct Answer: D (Portable emergency lighting, life-saving equipment, first aid supplies, emergency water and food and communication equipment, checked periodically)
💡 A ship should carry and check periodically the emergency supplies: portable emergency lighting, life-saving equipment, first aid medicines and equipment, emergency water and food, portable communication equipment including two-way VHF and damage control and firefighting equipment, ensuring they are available immediately in an emergency.
✗
Question 68. What should be done about fire doors that do not close properly?
Your Answer: (Not answered)
Correct Answer: B (Adjust or replace the self-closing device and seals promptly so that they close reliably in a fire)
💡 A fire door that does not close properly, for example because the self-closing device has failed, the frame is distorted or the seal has perished, allows smoke and flame to pass. It should be adjusted or its parts replaced promptly to close reliably in a fire; securing it with rope is not permitted.
✗
Question 69. What should be done before abandoning ship under SOLAS and good practice?
Your Answer: (Not answered)
Correct Answer: A (Transmit a distress alert where possible, take necessary emergency equipment and documents and close relevant openings)
💡 SOLAS and good practice require a distress alert to be transmitted where possible with the position given, necessary equipment and documents such as copies of certificates and the crew list to be taken, and watertight openings closed, improving the chance of rescue and later handling.
✗
Question 70. Under the ISPS Code, which security level indicates the highest threat, i.e. a security incident is probable or imminent?
Your Answer: (Not answered)
Correct Answer: C (Level 3)
💡 SOLAS XI-2/3: under the ISPS Code, security level 3 indicates that a security incident is probable or imminent.
✗
Question 71. What does the Polar Code require regarding life-saving appliances in polar waters?
Your Answer: (Not answered)
Correct Answer: C (They must work at low temperature, with measures to extend survival time in the polar environment)
💡 The Polar Code requires life-saving appliances to function at low temperature and for measures to extend survival time, such as additional thermal protection, collective survival equipment and search aids.
✗
Question 72. What are the core documents of the safety management system required by SOLAS Chapter IX?
Your Answer: (Not answered)
Correct Answer: A (A safety management manual together with supporting procedures covering the elements of the system)
💡 SOLAS IX and the ISM Code require a safety management manual with supporting procedures covering the elements of the Code. A policy statement or a single plan does not constitute a complete system.
✗
Question 73. What is characteristic of a fixed water mist system used in machinery spaces?
Your Answer: (Not answered)
Correct Answer: C (It covers the burning surface with fine water mist, cooling and smothering the fire with less hazard to personnel)
💡 A fixed water mist system covers the burning surface with fine droplets, cooling and inerting the fire. It may be used for oil fires in machinery spaces and is relatively benign to personnel and the environment.
✗
Question 74. From where may the ventilation openings of machinery spaces be closed?
Your Answer: (Not answered)
Correct Answer: A (From outside the machinery space)
💡 SOLAS II-2/9: ventilation openings shall be capable of being closed from outside the space.
✗
Question 75. Three crew members were replaced during the voyage. What should be done with the muster list?
Your Answer: (Not answered)
Correct Answer: B (It must be amended without delay and re-posted so that new crew know their duties)
💡 SOLAS III/37 requires the muster list to be kept up to date as the crew changes and re-posted, so that every person on board can find his duty and muster station. An oral briefing or a log entry alone is not sufficient.
✗
Question 76. What do SOLAS and good practice require for emergency instructions after a distress?
Your Answer: (Not answered)
Correct Answer: D (Muster, embarkation and abandonment instructions to crew and passengers, organised in accordance with the muster list)
💡 SOLAS requires the muster list, signs and emergency announcements to enable crew and passengers to proceed in an orderly way to the muster and embarkation stations on abandonment. Independent action causes confusion and casualties.
✗
Question 77. What is the main purpose of the requirements for fire main diameter and pressure?
Your Answer: (Not answered)
Correct Answer: A (To ensure that the required number of jets can be supplied simultaneously with effective reach)
💡 The SOLAS II-2 requirements for fire main diameter and pressure ensure that the required number of jets can be maintained simultaneously at an effective reach when the fire pumps are running.
✗
Question 78. For a ship with no emergency generator, for how long shall the GMDSS reserve source of energy supply?
Your Answer: (Not answered)
Correct Answer: C (6 hours)
💡 SOLAS IV/13: the reserve source shall be capable of supplying for 6 hours on ships without an emergency generator.
✗
Question 79. What is the master's duty when an incident involves dangerous goods?
Your Answer: (Not answered)
Correct Answer: A (Report to the authorities and take emergency measures)
💡 Report to the authorities and take the appropriate emergency measures.
✗
Question 80. What does the weekly inspection of a lifeboat require regarding the engine?
Your Answer: (Not answered)
Correct Answer: A (Start and run it for the prescribed period, checking starting, running and cooling)
💡 SOLAS requires the boat engine to be started and run for the prescribed period, normally not less than three minutes, during the weekly inspection, checking that it starts readily, runs smoothly and discharges cooling water properly. An appearance or level check alone would not reveal an actual fault.
✗
Question 81. What do SOLAS and the IMDG Code require for marking and labelling of dangerous goods packages?
Your Answer: (Not answered)
Correct Answer: D (The proper shipping name, UN number and the relevant hazard class label)
💡 SOLAS VII and the IMDG Code require dangerous goods packages to show the proper shipping name, the UN number and the relevant hazard class label, including the marine pollutant mark, so that the crew can identify the hazard and act accordingly.
✗
Question 82. What is the role of the designated person ashore under the ISM Code?
Your Answer: (Not answered)
Correct Answer: D (To monitor the safety and pollution prevention aspects of the ship's operation and ensure adequate resources and shore support)
💡 ISM Code 4 requires the company to designate a person or persons ashore to monitor the safety and pollution prevention aspects of the operation of each ship and to ensure adequate resources and shore support are provided, acting as the link between company and ship.
✗
Question 83. What is the main characteristic of a "bulk carrier" as defined in SOLAS XII/1?
Your Answer: (Not answered)
Correct Answer: D (A ship generally having a single deck, top side tanks and hopper side tanks, intended primarily to carry dry cargo in bulk)
💡 SOLAS XII/1 defines a bulk carrier as a ship generally with a single deck, top side tanks and hopper side tanks, intended primarily to carry dry cargo in bulk. Not every ship carrying bulk cargo falls within the definition.
✗
Question 84. What is required of machinery space fans in a fire?
Your Answer: (Not answered)
Correct Answer: A (Capable of being stopped promptly and ventilation closed from outside)
💡 Fans shall be capable of prompt stopping and ventilation closed from outside.
✗
Question 85. What is the effect of contamination of a fire detector by oil fume or dust?
Your Answer: (Not answered)
Correct Answer: C (It may cause false alarms or reduced sensitivity leading to a missed alarm, so periodic cleaning and maintenance are required)
💡 A detector contaminated by oil, dust or moisture may give frequent false alarms or lose sensitivity and miss an alarm. It should therefore be cleaned and function tested at the prescribed intervals, especially in heavily contaminated spaces such as the galley and machinery space.
✗
Question 86. What does SOLAS address regarding stowage and immediate availability of survival craft?
Your Answer: (Not answered)
Correct Answer: C (Stowed where they can be reached and launched promptly, in a condition of immediate readiness)
💡 SOLAS requires survival craft to be stowed where they can be reached and launched promptly and to be in a condition of immediate readiness, with gravity davits able to be released without preparation. Dismantling them or stowing them in a hold makes them unusable on abandonment.
✗
Question 87. After failure of the main steering gear, within what time must the auxiliary steering gear be brought into use?
Your Answer: (Not answered)
Correct Answer: D (7 seconds for a passenger ship and 45 seconds for a cargo ship, the changeover being proved in drills)
💡 The time is fixed by type of ship: on a passenger ship the auxiliary gear must be capable of being brought into use within 7 seconds after failure of the main gear, and within 45 seconds on a cargo ship; the arrangements must also be such that failure of one does not render the other inoperative, and the changeover is worked and logged at drills. Blurring the figures into one minute, or treating multiple power units as replacing the auxiliary gear, is found out in the exercise or in a real failure.
✗
Question 88. At what angle of list must lifeboat launching appliances still operate?
Your Answer: (Not answered)
Correct Answer: A (A list of up to 20 degrees to either side)
💡 SOLAS requires launching appliances to be capable of operation with the ship listed up to 20 degrees either way. Free-fall lifeboats have additional conditions such as trim by the stern.
✗
Question 89. Insulation was removed from a fire division for work and not replaced. What is the finding?
Your Answer: (Not answered)
Correct Answer: B (A deficiency; missing insulation reduces the fire performance of the division and must be restored promptly)
💡 Insulation removed from a fire division, for example to gain access during work, and not replaced significantly reduces its fire performance, so heat and fire cannot be effectively contained. It is a deficiency affecting safety and must be restored promptly with approved material.
✗
Question 90. Regarding launching and recovery of survival craft:
Your Answer: (Not answered)
Correct Answer: B (training shall be given in both launching and recovery)
💡 SOLAS III/19 requires training in both launching and recovery of survival craft.
✗
Question 91. What is the purpose of a company's periodic visits and inspections of its ships?
Your Answer: (Not answered)
Correct Answer: A (To verify the effective implementation of the system on board, identify and help resolve problems and promote continual improvement)
💡 The ISM Code requires the company to inspect its ships periodically, through internal audits and visits, in order to verify that the system works effectively on board, identify non-conformities and opportunities for improvement and provide support, not merely to assess the crew. Problems found should be followed up to closure.
✗
Question 92. How many rocket parachute flares must each survival craft carry?
Your Answer: (Not answered)
Correct Answer: A (4)
💡 SOLAS III/7.1 requires four rocket parachute flares in each survival craft. Six is the usual number for hand flares, which is easily confused with this.
✗
Question 93. What operating condition must be considered in designing the capacity of the main source of power?
Your Answer: (Not answered)
Correct Answer: A (It must carry the maximum normal load with margin for short overloads and starting currents)
💡 SOLAS requires the main source to carry the maximum normal load with allowance for short duration overloads such as motor starting. Insufficient capacity leads to tripping or failure to start equipment.
✗
Question 94. High-velocity vent valves of a tanker cargo tank venting system shall have a gas discharge velocity of not less than:
Your Answer: (Not answered)
Correct Answer: D (30 m/s)
💡 SOLAS II-2/4 requires high-velocity vent valves to discharge at a velocity of not less than 30 m/s.
✗
Question 95. What are the usual transmit power settings of a ship's VHF radiotelephone?
Your Answer: (Not answered)
Correct Answer: A (1 watt (low) and 25 watts (high))
💡 A ship's VHF normally has two settings, one watt for low power and twenty-five watts for high power, low power being used for short-range communication to reduce interference and high power for long range or distress communication to ensure coverage. Selecting the right setting is a basic watchkeeping requirement.
✗
Question 96. A ship is to load dangerous goods but lacks the emergency information required. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (Obtain the EmS Guide, MFAG and other emergency information before loading; otherwise refuse to load)
💡 SOLAS VII requires a ship carrying dangerous goods to have the EmS Guide, MFAG and similar emergency information. Without it the master should not agree to load. Loading first and supplying the information afterwards would leave the ship unable to respond effectively to an incident, a breach.
✗
Question 97. The intermediate verification of a Safety Management Certificate shall be carried out:
Your Answer: (Not answered)
Correct Answer: A (around the mid-point of the certificate's validity)
💡 SOLAS IX/4 (ISM) requires intermediate verification around the mid-point of the SMC validity.
✗
Question 98. For how long must the GMDSS reserve source of energy supply the radio installation when the main source fails under SOLAS IV/9?
Your Answer: (Not answered)
Correct Answer: C (At least one hour, for both passenger and cargo ships)
💡 SOLAS IV/9 requires the reserve source to supply the radio installation for at least one hour. The 18-hour figure applies to emergency lighting on cargo ships under a different regulation.
✗
Question 99. On what basis must first aid be given in a dangerous goods incident involving poisoning or burns?
Your Answer: (Not answered)
Correct Answer: D (MFAG, the Medical First Aid Guide for use in accidents involving dangerous goods)
💡 SOLAS VII requires MFAG to be carried on board, with first aid given according to the relevant card, such as decontamination, oxygen and artificial respiration, gaining time for subsequent medical treatment.
✗
Question 100. Which VHF channel is used for DSC watchkeeping?
Your Answer: (Not answered)
Correct Answer: A (Channel 70)
💡 Channel 70 (156.525 MHz) is for DSC only.