Question 1. In an overtaking situation, how are responsibility and duties allocated?
Your Answer: (Not answered)
Correct Answer: C (The overtaking vessel must keep out of the way and the overtaken vessel keeps her course and speed)
💡 Under the collision regulations the overtaking vessel must keep out of the way of the vessel being overtaken in all situations until finally past and clear, while the overtaken vessel keeps her course and speed. A vessel approaching from more than twenty-two point five degrees abaft the beam of the vessel ahead is overtaking.
✗
Question 2. What does SOLAS require regarding safety devices on boilers, pressure vessels and air receivers?
Your Answer: (Not answered)
Correct Answer: D (Safety valves or protective devices must be fitted to prevent damage or explosion from overpressure)
💡 SOLAS II-1 requires boilers, pressure vessels and air receivers to be fitted with safety valves or protective devices that relieve or operate reliably on overpressure, preventing damage or explosion.
✗
Question 3. A cargo ship has lost all main power and is on the emergency generator. Under SOLAS II-1/42, for how long must emergency lighting be maintained on a cargo ship?
Your Answer: (Not answered)
Correct Answer: B (18 hours)
💡 Emergency lighting must be maintained for 18 hours on cargo ships and 36 hours on passenger ships. Three hours is the minimum duration for the electric safety lamp of a firefighter's outfit — the two figures are easily confused.
✗
Question 4. Each lifebuoy shall be fitted with a buoyant lifeline of a length of not less than:
Your Answer: (Not answered)
Correct Answer: D (18 m)
💡 SOLAS III/32 requires each lifebuoy to be fitted with a buoyant lifeline of not less than 18 m.
✗
Question 5. What is required when new piping is passed through a fire division during a conversion?
Your Answer: (Not answered)
Correct Answer: D (Execute the approved penetration sealing arrangement, updating the fire control plan and records)
💡 New penetrations of a fire division require the approved penetration sealing arrangement to be used, with approved seals of equivalent fire rating, while the fire control plan and records are updated and the work verified by the classification society. A plain hole or cement sealing destroys the fire integrity of the division.
✗
Question 6. How must alarms be handled at sea?
Your Answer: (Not answered)
Correct Answer: D (Establish the cause and deal with it promptly; alarms must not be silenced or inhibited at will)
💡 Every alarm, whether fire, machinery or water ingress, requires the cause to be established and appropriate action taken. It must not be silenced or inhibited at will for the sake of quiet. Inhibiting alarms conceals real faults, so that a genuine problem goes unnoticed.
✗
Question 7. What does a B-15 class division mean?
Your Answer: (Not answered)
Correct Answer: D (It prevents the passage of flame and limits temperature rise for 15 minutes in the standard fire test)
💡 Class B divisions are graded B-15 and B-0, the figure being the period in minutes for which temperature rise is limited in the standard fire test. Class B divisions are of non-combustible material, preventing passage of flame with lower strength than class A.
✗
Question 8. How must deck cargo such as timber be secured against shifting?
Your Answer: (Not answered)
Correct Answer: A (Properly lashed and secured)
💡 Deck cargo must be properly lashed in accordance with the securing requirements and checked during the voyage.
✗
Question 9. What does a passenger drill on a passenger ship usually include?
Your Answer: (Not answered)
Correct Answer: B (Demonstrating how to don a lifejacket, explaining muster stations and emergency procedures and indicating where appliances are stowed)
💡 SOLAS requires a passenger drill within 24 hours of embarkation, or an equivalent means, including demonstrating how to don a lifejacket, explaining the muster stations and emergency signals and indicating where appliances are stowed and the emergency procedures, so that passengers act correctly in an emergency.
✗
Question 10. Under what conditions shall a lifeboat engine be able to start?
Your Answer: (Not answered)
Correct Answer: B (Even at the specified low temperature)
💡 It shall start even at the specified low temperature.
✗
Question 11. What does SOLAS specifically require regarding the correction of nautical charts and publications?
Your Answer: (Not answered)
Correct Answer: B (They must be corrected promptly from notices to mariners, with a record of the corrections kept)
💡 SOLAS V/27 requires charts and nautical publications to be corrected promptly from notices to mariners with a record kept, such as a chart correction log. Late or missing correction is a common ground for detention.
✗
Question 12. The sea anchor in a lifeboat is used to:
Your Answer: (Not answered)
Correct Answer: A (keep the boat head to wind and reduce drift in rough seas)
💡 SOLAS III/34 requires a sea anchor to keep the boat head to wind and reduce drift.
✗
Question 13. Each lifeboat shall be provided with equipment including:
Your Answer: (Not answered)
Correct Answer: B (a complete set including oars, compass, sea anchor, first-aid kit, etc.)
💡 SOLAS III/34 lists lifeboat equipment including oars, compass, sea anchor, first-aid kit, food and water.
✗
Question 14. What does SOLAS address regarding SART batteries and testing?
Your Answer: (Not answered)
Correct Answer: D (Periodic testing and checking of battery expiry, ensuring the prescribed standby and operating time)
💡 SOLAS requires periodic testing of the SART and checking of its battery condition and expiry, ensuring the prescribed standby and operating periods. An unsuitable battery means the searching radar cannot detect the survival craft.
✗
Question 15. What navigational measures should the officer of the watch take in restricted visibility?
Your Answer: (Not answered)
Correct Answer: D (Engines ready for immediate manoeuvre, enhanced look-out and radar observation, reducing speed as required and using sound signals)
💡 COLREG Rule 19 and good seamanship require engines ready for immediate manoeuvre, an enhanced look-out and radar observation, reduction of speed or stopping where necessary and the prescribed sound signals, so that other vessels are warned in due time.
✗
Question 16. What is the principal safety hazard of a fixed CO2 system?
Your Answer: (Not answered)
Correct Answer: B (Asphyxiation of personnel)
💡 CO2 displaces oxygen, so personnel must be clear and alarms given before release.
✗
Question 17. Lifeboats of a cargo ship shall be capable of being launched when the ship is listed up to:
Your Answer: (Not answered)
Correct Answer: B (20°)
💡 SOLAS III/16 requires launching appliances to operate with the ship listed up to 20°.
✗
Question 18. What separation is required between control stations such as the bridge or fire control station and accommodation spaces?
Your Answer: (Not answered)
Correct Answer: A (Normally A-60 or A-30 class divisions, so the control station remains usable in a fire)
💡 Control stations provide command and fire control functions in an emergency, so SOLAS requires A-60 or A-30 boundaries with accommodation spaces according to their position, ensuring they remain usable.
✗
Question 19. How is agreement between what is written and what is done verified?
Your Answer: (Not answered)
Correct Answer: B (comparing practice against the document item by item at set intervals, and where they disagree finding the cause: weak training or supervision where the practice is at fault, a document change where the document is wrong)
💡 The comparison is made at intervals through internal audit, ship visits and day to day supervision, and it looks at movements rather than forms: if the document says a lifejacket on boarding, whether anyone skips it; if it says the engine tested before passing alongside, whether the time in the record stands up. A disagreement has to be put in one of two boxes - where execution falls short, training and supervision are tightened and a non-conformity raised if needed; where the document simply does not match reality, it is revised and the revision comes back to the ship, or the two stay apart. Doing it in a heap before each audit leaves the system permanently detached from practice.
✗
Question 20. What should be noted in steering and handling a lifeboat?
Your Answer: (Not answered)
Correct Answer: A (Familiarity with the rudder and propulsion controls, coordination with those on board and avoiding injury from wave impact)
💡 Handling a lifeboat involves familiarity with the way the rudder and propulsion respond, coordination with the persons on board such as even distribution, holding on and avoiding high speed in heavy seas, preventing persons being thrown about or lost over the side.
✗
Question 21. What are the key points in checking the falls of a launching appliance?
Your Answer: (Not answered)
Correct Answer: C (Check for broken wires, corrosion, deformation and the security of the terminations, replacing when beyond the limit)
💡 The falls of a launching appliance should be checked for the number of broken wires, corrosion, kinks and deformation and for the security of the terminations, replaced at once when beyond the rejection criteria. Failure of the falls would drop the craft during launching with fatal consequences.
✗
Question 22. What is the basic requirement of a proper look-out during a navigational watch?
Your Answer: (Not answered)
Correct Answer: A (Maintain look-out by sight and hearing as well as by all available means, with the look-out not impeded by other duties)
💡 COLREG and SOLAS require a look-out at all times by sight, hearing and all available means, making a full appraisal of the situation and risk of collision. The look-out must not be given duties that interfere with the watch.
✗
Question 23. Muster and embarkation stations shall:
Your Answer: (Not answered)
Correct Answer: D (be adequately illuminated and supplied from the emergency source)
💡 SOLAS III/11 requires adequate lighting of muster and embarkation stations from the emergency source.
✗
Question 24. What size should the international shore connection fitted on ships of 500 GT and above be?
Your Answer: (Not answered)
Correct Answer: A (65 mm)
💡 The international shore connection is 65 mm in diameter.
✗
Question 25. What does SOLAS address regarding electrical equipment in a paint locker?
Your Answer: (Not answered)
Correct Answer: C (Explosion-protected equipment or no electrical equipment within the space)
💡 SOLAS requires explosion-protected equipment in a paint locker, or no electrical equipment inside it, such as lighting fitted outside, preventing an electrical spark from igniting paint vapour.
✗
Question 26. The carriage of dangerous goods in packaged form shall follow:
Your Answer: (Not answered)
Correct Answer: B (the International Maritime Dangerous Goods (IMDG) Code)
💡 SOLAS VII/3: the carriage of dangerous goods in packaged form shall follow the IMDG Code.
✗
Question 27. What limitation must the officer of the watch bear in mind when using ARPA?
Your Answer: (Not answered)
Correct Answer: D (Target tracking may be lost or erroneous due to sea state, target manoeuvres or shadowing, so it cannot be relied upon entirely)
💡 ARPA tracking is affected by sea state, target manoeuvres, shadowing and input data accuracy, and targets may be lost or plotted in error. The officer must cross-check with the raw radar picture and visual look-out.
✗
Question 28. What does the periodic test of launching appliances at intervals not exceeding five years involve?
Your Answer: (Not answered)
Correct Answer: A (A launching test with the rated complement or prescribed load, verifying performance under load)
💡 SOLAS III/35 requires a test with load, at the rated complement or an equivalent, at intervals of not exceeding five years, actually verifying the reliability of the brake, release gear and structure under load. An empty or static test does not meet the requirement.
✗
Question 29. What is the minimum period for which the emergency source of power of a cargo ship should supply the emergency load?
Your Answer: (Not answered)
Correct Answer: A (Eighteen hours)
💡 Under SOLAS II-1/42 the emergency source of power of a cargo ship should supply the specified emergency load for at least eighteen hours, thirty-six hours for a passenger ship, so that emergency lighting, steering gear, communications and alarms continue after a blackout.
✗
Question 30. When a ship changes flag, which is required?
Your Answer: (Not answered)
Correct Answer: D (Both the former and new flag States must recognise the ship's safety status)
💡 Flag change requires formal recognition of safety status by both the former and new flag States.
✗
Question 31. What shall the Ship Security Plan contain?
Your Answer: (Not answered)
Correct Answer: B (Security organisation, duties, measures and training)
💡 Security organisation, duties, protective measures and training.
✗
Question 32. An EPIRB was found with an expired battery. What is the finding?
Your Answer: (Not answered)
Correct Answer: B (A deficiency; the battery must be within its expiry date, as an expired battery affects distress alerting capability)
💡 An expired EPIRB battery means the equipment cannot sustain the prescribed transmission period, normally not less than 48 hours, in a distress. This is a deficiency affecting distress alerting capability, and the battery or the equipment should be replaced at once with the release mechanism checked.
✗
Question 33. What is the principle for the audit requirements of the Document of Compliance (DOC)?
Your Answer: (Not answered)
Correct Answer: C (Validity generally not more than five years with an annual audit within three months before or after each anniversary date)
💡 Under the ISM Code a company's Document of Compliance has a usual validity of not more than five years with an annual audit within three months before or after each anniversary date, to confirm the continued effective operation of the company's safety management system. A failed annual audit affects the ship's SMC.
✗
Question 34. Muster stations shall be located:
Your Answer: (Not answered)
Correct Answer: C (close to the embarkation station and readily accessible)
💡 SOLAS III/11 requires muster stations to be located near the embarkation stations and readily accessible.
✗
Question 35. On what basis is the Polar Ship Certificate issued, and what does it state?
Your Answer: (Not answered)
Correct Answer: D (issued on the results of survey, attesting conformity with the applicable polar safety and pollution requirements and recording the category and the limits)
💡 The work comes before the paper: before trading in polar waters the ship is assessed for the areas she intends to reach, a polar water operational manual is built on that assessment covering both safety and pollution prevention, and survey then establishes that the arrangements, equipment, training and manual on board answer one another. The certificate records the ship's category, the ice conditions she may operate in, the limitations and any exemptions attached, and is examined and renewed as required. The category is tied to the life-saving, fire and radio arrangements, so ice class alone says nothing; and a class notation for ice is given under the society's own rules, which is not the category in the Code. Without the certificate the ship does not trade there, and a master cannot plead that this voyage meant to stay clear of ice.
✗
Question 36. The weekly inspection of launching appliances shall include checking:
Your Answer: (Not answered)
Correct Answer: D (the davits, falls and brakes for proper condition)
💡 SOLAS III/20 requires weekly inspection of davits, falls and brakes.
✗
Question 37. What does SOLAS V/23 require of the ship regarding pilot ladders?
Your Answer: (Not answered)
Correct Answer: B (Regular inspection and maintenance in good condition, with an escort arranged during embarkation and disembarkation)
💡 SOLAS V/23 requires the ship to inspect and maintain the pilot transfer arrangements regularly with records kept, and to arrange an escort during embarkation and disembarkation.
✗
Question 38. Under the ISM Code, the master shall:
Your Answer: (Not answered)
Correct Answer: A (periodically review the SMS and report on its effectiveness to the company)
💡 SOLAS IX/5 (ISM) requires the master to periodically review the SMS and report its effectiveness.
✗
Question 39. What marking shall survival craft have for night detection?
Your Answer: (Not answered)
Correct Answer: D (Lighting or retro-reflective material to aid detection)
💡 Lighting or retro-reflective material to aid detection.
✗
Question 40. What corridor length limit does SOLAS address in the escape requirements for accommodation spaces?
Your Answer: (Not answered)
Correct Answer: B (An enclosed corridor exceeding 13 m must have escape routes at both ends)
💡 SOLAS II-2/13 requires an enclosed corridor more than 13 m long to have access to escape routes at both ends, so that persons are not trapped in a long corridor with a single exit.
✗
Question 41. Steering trials are run at maximum service speed. Under SOLAS II-1/29, within what time must the main steering gear put the rudder over from 35 degrees on one side to 30 degrees on the other?
Your Answer: (Not answered)
Correct Answer: D (Not more than 28 seconds)
💡 SOLAS II-1/29 requires the main steering gear, at deepest seagoing draught and maximum service speed, to put the rudder over from 35 degrees to 30 degrees within 28 seconds. The 60-second limit applies to the auxiliary steering gear for 15 degrees to 15 degrees.
✗
Question 42. What key information must a DSC distress alert contain under GMDSS?
Your Answer: (Not answered)
Correct Answer: A (The ship's identity (MMSI), her position and the nature of distress)
💡 A DSC distress alert must convey the ship's identity, her last known position with time and the nature of distress, enabling the rescue service to act. Owner and cargo details are not included.
✗
Question 43. What does SOLAS address regarding lighting in machinery spaces?
Your Answer: (Not answered)
Correct Answer: B (Adequate illumination, with emergency lighting at key positions to allow inspection and emergency operation)
💡 SOLAS requires machinery spaces to be adequately illuminated, with emergency lighting at key positions such as escape routes, the emergency steering position and switchboards, so that inspection, operation and emergency action can all be carried out.
✗
Question 44. When a fire breaks out in a machinery space, what is the principle for dealing with the ventilation system?
Your Answer: (Not answered)
Correct Answer: A (Stop the relevant fans and close dampers and fire flaps, cutting off the supply of fresh air and the spread of smoke)
💡 When a fire breaks out in a machinery space the fans of the affected space should be stopped and the dampers and fire flaps closed, cutting off the fresh air supply and preventing smoke spreading to other spaces through the ducts and creating the closed condition needed for releasing a fixed extinguishing system. Increasing ventilation blindly feeds the fire.
✗
Question 45. What identification is required for fire main isolation valves?
Your Answer: (Not answered)
Correct Answer: A (Clear marking of their position and direction of operation, enabling prompt and correct action in a fire)
💡 SOLAS requires fire main isolation valves to be clearly marked as to position and direction of operation, so that in an emergency the crew can find them quickly and correctly isolate the section affected. Missing or wrong marking delays firefighting.
✗
Question 46. In which circumstances must the supply of inert gas to cargo tanks be stopped?
Your Answer: (Not answered)
Correct Answer: A (When the oxygen content of the gas exceeds the prescribed limit or the system fails)
💡 Where the oxygen content of the inert gas exceeds the limit or the system develops a fault, supply must be stopped and contingency measures taken. Otherwise gas with too much oxygen enters the tanks and defeats the inerting.
✗
Question 47. What action do SOLAS and STCW require if the main engine fails while under way?
Your Answer: (Not answered)
Correct Answer: A (Notify the bridge immediately, display the appropriate lights, shapes or sound signals and take action such as anchoring or other avoidance measures)
💡 Engine failure deprives the ship of manoeuvrability. The bridge must be informed at once, the lights, shapes or signals for a vessel not under command displayed, and measures such as anchoring taken to avoid collision, with the authorities informed.
✗
Question 48. When a pilot is on board, how is responsibility allocated?
Your Answer: (Not answered)
Correct Answer: A (The pilot provides pilotage and advice but does not relieve the master of responsibility for the safety of the ship)
💡 A pilot on board provides local pilotage and manoeuvring advice but does not relieve the master of responsibility for the safety of the ship. The master and officer of the watch should still monitor the ship's movement and, if the pilot's orders are likely to cause danger, should speak up promptly and take necessary action.
✗
Question 49. What shall the master do on encountering dangerous ice or derelicts?
Your Answer: (Not answered)
Correct Answer: B (Communicate the danger immediately to ships in the vicinity and to the competent authority ashore)
💡 SOLAS V/31: the master shall communicate the danger immediately to nearby ships and to the competent authority.
✗
Question 50. What safety is required in spaces adjacent to a hold containing cargo that may release harmful gas?
Your Answer: (Not answered)
Correct Answer: B (Monitor gas concentrations in adjacent spaces such as enclosed passages and stores, preventing gas ingress)
💡 For cargoes that may release harmful or flammable gas, the IMSBC Code requires monitoring not only inside the hold but also the possibility of gas entering adjacent enclosed spaces such as passages, stores and the machinery space through bulkheads, piping and access ways, preventing poisoning or the ignition of the gas.
✗
Question 51. What does SOLAS address regarding stowage and immediate availability of survival craft?
Your Answer: (Not answered)
Correct Answer: C (Stowed where they can be reached and launched promptly, in a condition of immediate readiness)
💡 SOLAS requires survival craft to be stowed where they can be reached and launched promptly and to be in a condition of immediate readiness, with gravity davits able to be released without preparation. Dismantling them or stowing them in a hold makes them unusable on abandonment.
✗
Question 52. How must records of servicing and inspection of life-saving appliances be handled under SOLAS III?
Your Answer: (Not answered)
Correct Answer: B (They must be kept on board and produced at statutory surveys)
💡 SOLAS III requires records of inspections and maintenance of life-saving appliances to be kept on board for verification at statutory and PSC inspections. Company-only records or oral reports are not sufficient.
✗
Question 53. Which satellite communication equipment must a ship in sea area A3 carry?
Your Answer: (Not answered)
Correct Answer: B (An Inmarsat ship earth station (SES))
💡 Sea area A3 lies within Inmarsat coverage, so an Inmarsat ship earth station is required. MF/HF is the principal means in sea area A4.
✗
Question 54. What principle applies to the officer of the watch in using navigational aids?
Your Answer: (Not answered)
Correct Answer: B (They should be used early and correctly, with information cross-checked rather than relying on a single aid)
💡 Radar, AIS and ECDIS should be used early and correctly, with information cross-checked between sources, rather than forming a collision avoidance judgement from a single aid or from experience alone.
✗
Question 55. What is required of the torch carried in survival craft?
Your Answer: (Not answered)
Correct Answer: D (It must be watertight and capable of continuous illumination, provided in the craft for use at night)
💡 SOLAS requires survival craft to carry a watertight torch, normally one per boat or as prescribed, providing light at night after abandonment for checking the condition of the craft, signalling or assisting a person. An ordinary torch is not waterproof and would fail at sea.
✗
Question 56. Which measure prevents static hazards in the cargo area of a tanker?
Your Answer: (Not answered)
Correct Answer: D (Earthing of piping and tanks and similar anti-static measures)
💡 Earthing of piping and tanks and other anti-static measures.
✗
Question 57. What is the focus of survey for ageing bulk carriers under SOLAS and the ESP?
Your Answer: (Not answered)
Correct Answer: C (The effect on hull strength of corrosion, fatigue cracking and structural deformation)
💡 The ESP and SOLAS require close-up examination of ageing bulk carriers for corrosion, fatigue cracking and deformation, with thickness measurement to assess remaining hull strength and decide on repair or reinforcement.
✗
Question 58. Which is NOT a function of the GMDSS?
Your Answer: (Not answered)
Correct Answer: A (Commercial advertising)
💡 The GMDSS does not provide commercial advertising.
✗
Question 59. What compliance with ship reporting systems is required?
Your Answer: (Not answered)
Correct Answer: A (Report at the prescribed positions and times with the prescribed content and report changes in the ship's condition promptly)
💡 SOLAS V/11 requires ships to report the prescribed content, such as name, position, course and speed, cargo and defects, at the prescribed positions and times, and to report promptly any change affecting the safety of navigation, such as equipment failure or deviation from the route.
✗
Question 60. What checking of survival craft stowage cradles is required?
Your Answer: (Not answered)
Correct Answer: C (Check the structure for corrosion and deformation and the lashings and limiters for reliability)
💡 Survival craft cradles should be checked for serious corrosion or deformation of the structure and for the reliability of the lashings and limiters, with the sliding surfaces smooth so that launching is unobstructed. Structural failure would prevent launching or allow the craft to move in a seaway, a serious hazard.
✗
Question 61. For a hydraulic steering gear, provision shall be made to detect abnormal conditions by means of:
Your Answer: (Not answered)
Correct Answer: C (a tank level gauge with a low-level alarm)
💡 SOLAS II-1/29 requires a tank level gauge with a low-level alarm to monitor hydraulic fluid leakage.
✗
Question 62. What should be met for electrical equipment and operations in the cargo area of a tanker?
Your Answer: (Not answered)
Correct Answer: C (Explosion-protected equipment should be used and requirements such as gas testing, earthing and static protection observed to control ignition sources)
💡 In the cargo area of a tanker electrical equipment should be of the specified explosion-protected type and operations should observe requirements such as gas testing, effective earthing and protection against static electricity, including controlling flow rates and using anti-static equipment, controlling ignition sources and static discharge to prevent flammable gas from being ignited. Gas testing and a permit before operations are basic requirements.
✗
Question 63. What must a Declaration of Security contain?
Your Answer: (Not answered)
Correct Answer: B (The responsibilities, contacts and measures of each party at the security level applicable and the procedure if it changes)
💡 The ISPS Code requires a Declaration of Security to set out the responsibilities, points of contact and measures of the ship and the port facility at the applicable security level, together with the procedure if that level changes, making the security responsibilities during the interface clear.
✗
Question 64. Class A and class B divisions: what separates them?
Your Answer: (Not answered)
Correct Answer: A (class A of steel or equivalent with non-combustible insulation, stopping flame and smoke; class B need only be non-combustible and for a shorter time)
💡 Three things decide the class: the material, the limit on temperature rise on the unexposed face, and the time the division stands up to the standard fire test. Class A asks for steel or equivalent material with non-combustible insulation behind, so that neither flame nor smoke passes, and for the longest test period; class B asks only that the material be non-combustible, with lower insulation and strength and a much shorter time holding flame. Either class may be a bulkhead or a deck, the name not fixing the use; which class a boundary needs depends on how dangerous the space is, whether the ship carries passengers or cargo, and what the rules require around machinery spaces, stairways and control stations. Cut a hole for a pipe and leave it unsealed and the division stops being what it was, which is the commonest thing an inspection finds.
✗
Question 65. What is the main value of combining radar with ARPA?
Your Answer: (Not answered)
Correct Answer: C (Automatic tracking and computation of relative motion to assess collision risk)
💡 ARPA tracks targets automatically and computes CPA/TCPA to assess collision risk.
✗
Question 66. Which certificate shall a ship hold under the ISPS Code?
Your Answer: (Not answered)
Correct Answer: A (ISSC)
💡 The International Ship Security Certificate.
✗
Question 67. Where shall the emergency fire pump required by SOLAS be located?
Your Answer: (Not answered)
Correct Answer: C (Outside the machinery space)
💡 The emergency fire pump must be located outside the machinery space so that it remains available if that space is on fire.
✗
Question 68. What does SOLAS address regarding fire protection of the cargo pump room on a tanker?
Your Answer: (Not answered)
Correct Answer: D (Class A divisions at its boundaries with a fixed extinguishing system and fire detection inside)
💡 SOLAS requires the boundaries of a cargo pump room on a tanker to be class A divisions, with a fixed extinguishing system, normally CO2 or foam, and fire detection inside, since the pump room is a high risk space for accumulation and explosion of vapour.
✗
Question 69. At what stage must the initial survey for statutory certificates be completed?
Your Answer: (Not answered)
Correct Answer: A (Before the ship is put into service)
💡 SOLAS I/7 requires the initial survey to be completed and the certificates obtained before the ship is put into service. Operating without them is a serious breach of the Convention.
✗
Question 70. A distress signal from another ship is received while at sea. What must the master do?
Your Answer: (Not answered)
Correct Answer: B (Proceed with all speed to render assistance and report the situation to the rescue coordination centre)
💡 SOLAS requires the master to proceed with all speed to the assistance of persons in distress and to inform the search and rescue service. The obligation is released only in the circumstances prescribed, for example when other ships have been instructed to assist.
✗
Question 71. How many means of escape are required on each deck in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: A (At least two, widely separated)
💡 At least two widely separated means of escape per deck.
✗
Question 72. What does SOLAS Chapter XI-1 require of tankers and bulk carriers?
Your Answer: (Not answered)
Correct Answer: A (Enhanced surveys under the ESP)
💡 Enhanced surveys under the Enhanced Survey Programme.
✗
Question 73. How should training needs be identified and met?
Your Answer: (Not answered)
Correct Answer: C (Identified from the operation of the system, drills and inspections and then delivered)
💡 The ISM Code and STCW require the company and the ship to identify training needs from drill assessments, findings at inspection and the analysis of accidents and near misses, such as unfamiliarity with equipment or unclear emergency duties, and to organise targeted training and assessment, so that training matches the actual need.
✗
Question 74. A rate-of-turn indicator shall be fitted on ships of:
Your Answer: (Not answered)
Correct Answer: D (100 000 GT and above)
💡 SOLAS V/19: a rate-of-turn indicator shall be fitted on ships of 100 000 GT and above.
✗
Question 75. The gas regulating valve in a tanker inert gas system is used to:
Your Answer: (Not answered)
Correct Answer: C (regulate the flow of inert gas into cargo tanks and prevent backflow)
💡 SOLAS II-2/5 requires a gas regulating valve to control inert gas flow into cargo tanks and prevent backflow.
✗
Question 76. One space uses smoke detectors and another heat detectors. What is the main basis for choosing detector type?
Your Answer: (Not answered)
Correct Answer: A (The type and characteristics of fire likely in the space, such as smoke production or rapid temperature rise)
💡 SOLAS requires the detector type to suit the fire expected in the space: smoke detectors where smoke will be produced, heat detectors where rapid temperature rise without much smoke may occur. The wrong choice delays the alarm.
✗
Question 77. What are the common risks in launching and recovering survival craft?
Your Answer: (Not answered)
Correct Answer: A (Inadvertent operation of the release gear dropping the boat and injuring persons, and persons being crushed between the falls and the boat)
💡 The principal risks in launching and recovering a lifeboat include the release gear operating inadvertently and dropping the boat, persons being crushed between the falls and the boat and the boat striking the ship's side. Procedures should be strictly followed, coordination maintained and positions chosen with care.
✗
Question 78. What segregation is required between dangerous goods and foodstuffs?
Your Answer: (Not answered)
Correct Answer: D (Toxic or contaminating dangerous goods must be segregated from foodstuffs as the IMDG Code requires, preventing contamination)
💡 The IMDG Code requires class 6 toxic substances and materials liable to contaminate foodstuffs to be segregated from food cargoes as prescribed, normally in different holds or separated by a complete bulkhead, preventing leakage from contaminating food and poisoning persons. Stowing them adjacent on the ground that the packages are sound does not comply.
✗
Question 79. What does the Polar Code require regarding life-saving appliances in polar waters?
Your Answer: (Not answered)
Correct Answer: C (They must work at low temperature, with measures to extend survival time in the polar environment)
💡 The Polar Code requires life-saving appliances to function at low temperature and for measures to extend survival time, such as additional thermal protection, collective survival equipment and search aids.
✗
Question 80. What routine maintenance does the fire main require?
Your Answer: (Not answered)
Correct Answer: A (Periodic checks for corrosion and leakage, freedom of valve operation and prevention of water standing and freezing in the pipe)
💡 The fire main should be checked periodically for corrosion and leakage of the pipe wall and for freedom of valve operation, with standing water prevented from freezing in cold weather and periodic pressure testing, ensuring the system works reliably when needed.
✗
Question 81. What do SOLAS and good practice address regarding fire hose nozzles?
Your Answer: (Not answered)
Correct Answer: B (Spray nozzles suit oil fires and cooling, while solid jet nozzles suit distant solid fires)
💡 A spray nozzle cools and smothers with fine droplets, suiting oil fires and protective cooling, while a solid jet has greater range and impact, suiting solid fires. Choosing the wrong nozzle reduces effectiveness or spreads the fire.
✗
Question 82. What must be done on receiving maritime safety information at sea?
Your Answer: (Not answered)
Correct Answer: B (Assess its effect on the voyage promptly, adjusting course or speed and informing those concerned as necessary)
💡 On receiving navigational warnings or weather warnings, the officer of the watch should promptly assess their effect on the route, speed and operations, adjusting the plan and informing the master and others as necessary. Recording alone is not sufficient.
✗
Question 83. What does SOLAS address regarding automatic closing devices on air pipes?
Your Answer: (Not answered)
Correct Answer: C (Automatic closing devices must be fitted, closing and remaining effective under the impact of sea water)
💡 SOLAS and the Load Line Convention require air pipes to be fitted with automatic closing devices that close and remain effective under the impact of water shipped on deck, preventing sea water from entering the tanks. A manual device alone would fail unnoticed.
✗
Question 84. Besides the ship, where else shall life-saving appliances be provided?
Your Answer: (Not answered)
Correct Answer: A (One full set at the shore establishment)
💡 A full set shall also be kept at the shore establishment.
✗
Question 85. A voyage data recorder (VDR) shall be capable of retaining data for the preceding:
Your Answer: (Not answered)
Correct Answer: C (12 hours)
💡 SOLAS V/20: a VDR shall be capable of retaining data for at least the preceding 12 hours in a protective storage unit.
✗
Question 86. The ship shall carry for dangerous goods:
Your Answer: (Not answered)
Correct Answer: A (a list or manifest giving the name, class and location of the goods)
💡 SOLAS VII/5 requires a special list or manifest giving the name, class and location of the dangerous goods.
✗
Question 87. Which system, directly related to fire protection, is required in accommodation and service spaces?
Your Answer: (Not answered)
Correct Answer: B (Fixed fire detection and alarm system)
💡 SOLAS II-2/12 requires fixed fire detection and alarm systems in accommodation and service spaces.
✗
Question 88. If a ship fails a survey because of an equipment deficiency, what may the Administration do?
Your Answer: (Not answered)
Correct Answer: B (Require rectification within a period and re-inspect afterwards, with the validity of the certificate possibly affected meanwhile)
💡 SOLAS I/12 permits the Administration to suspend or withdraw a certificate where the ship does not comply. In practice rectification within a period and re-inspection is required before validity is maintained or restored. A certificate must not be issued with a deficiency outstanding.
✗
Question 89. What must the cargo information provided by the shipper include under SOLAS and the IMSBC Code?
Your Answer: (Not answered)
Correct Answer: A (The cargo name, group, stowage factor, trimming requirements and chemical hazards where applicable)
💡 SOLAS VI/1 and the IMSBC Code require information including the proper shipping name, cargo group, stowage factor, trimming requirements, moisture content and chemical hazards to be provided before loading, enabling the master to judge suitability and take the necessary precautions.
✗
Question 90. How should fire hoses be used in a fire drill?
Your Answer: (Not answered)
Correct Answer: C (Use hydrants and hoses at designated positions under the drill plan to verify the system, avoiding waste and damage to equipment)
💡 In a fire drill, hydrants and hoses should be used at designated safe positions to verify hose connection, nozzle handling and supply pressure, giving the crew practical experience. After using substantial water, drainage and anti-slip measures should be taken and cargo and equipment protected.
✗
Question 91. What measures prevent persons falling overboard?
Your Answer: (Not answered)
Correct Answer: C (Guard rails and lifelines, non-slip and well drained decks, good lighting and avoiding unnecessary deck work in heavy weather)
💡 Preventing a person from going overboard requires measures in combination: guard rails and lifelines at the sides, decks kept non-slip and well drained, lighting improved at night and in heavy weather, unnecessary deck work avoided and lifejackets and harnesses worn as required, reducing the risk.
✗
Question 92. The firefighter's outfit store is found locked with the key not readily available, so difficult to obtain in an emergency. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Firefighter's outfits must be readily available; improper stowage is a deficiency affecting firefighting readiness)
💡 The firefighter's outfits and their associated equipment should be stowed in a location that is easily reached and readily available. If locked with the key not promptly available it delays the donning and entry of the firefighters at the start of a fire. It is a deficiency affecting firefighting readiness.
✗
Question 93. What checking of embarkation ladders is required?
Your Answer: (Not answered)
Correct Answer: D (Check the steps, ropes and securing arrangements for damage and deterioration and that it is stowed for ready use)
💡 An embarkation ladder should have its steps checked for splitting, its ropes for corrosion and wear, its securing and connecting arrangements for reliability and its stowage for being readily available and quick to rig. A failed ladder causes a person to fall while boarding, so it is critical life-saving equipment.
✗
Question 94. Under the ISPS Code, which security level indicates the highest threat, i.e. a security incident is probable or imminent?
Your Answer: (Not answered)
Correct Answer: C (Level 3)
💡 SOLAS XI-2/3: under the ISPS Code, security level 3 indicates that a security incident is probable or imminent.
✗
Question 95. What does SOLAS require regarding the drive of fire pumps?
Your Answer: (Not answered)
Correct Answer: A (Each fire pump must be driven by an independent prime mover, so a single failure does not put all pumps out of action)
💡 SOLAS requires fire pumps to be independently driven, so that failure of the power supply or prime mover of one pump does not disable the others, ensuring an alternative pump remains available.
✗
Question 96. What does SOLAS address regarding fixed fire detection in ro-ro spaces?
Your Answer: (Not answered)
Correct Answer: B (A fixed fire detection and fire alarm system capable of detecting a fire in the vehicle space promptly)
💡 SOLAS requires ro-ro and vehicle spaces to have a fixed fire detection and fire alarm system. Because these spaces are large and vehicles carry fuel, fire spreads rapidly, and periodic rounds alone would not detect it in time.
✗
Question 97. What length must a rescue boat have under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Not less than 3.8 m and not more than 8.5 m)
💡 SOLAS requires a rescue boat to be not less than 3.8 m and not more than 8.5 m in length, balancing carrying capability against the ability to be manoeuvred and recovered quickly. Too small gives insufficient capacity, too large hinders rapid handling.
✗
Question 98. What must be done with the system documentation when a ship changes management company or owner?
Your Answer: (Not answered)
Correct Answer: A (Documentation consistent with the new company's system must be established with the corresponding audit and certification)
💡 When the management company or owner changes, the safety management system must be re-established on the basis of the new company's documentation, with the ship's procedures revised as necessary, and internal and Administration audits completed to obtain or reissue the DOC and SMC. Continuing with the previous company's documentation does not comply.
✗
Question 99. In which spaces must a bulk carrier be fitted with water ingress detection and alarm systems?
Your Answer: (Not answered)
Correct Answer: C (Cargo holds, ballast tanks and dry spaces)
💡 SOLAS XII/12 requires water level detectors with alarms in cargo holds, ballast tanks and dry spaces so that flooding is detected early.
✗
Question 100. What must be satisfied before dangerous goods packages are loaded on board?
Your Answer: (Not answered)
Correct Answer: C (Packages must be of a tested and certified type, in good condition, and correctly marked and labelled)