Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. After overhaul of launching appliances, what further test does SOLAS III/35 require?
Your Answer: (Not answered)
Correct Answer: A (A load test with the full complement at intervals of not more than five years)
💡 SOLAS III/35 requires that launching appliances be subjected to a test with the full complement on board at intervals of not more than five years, to verify performance under rated load.
✗
Question 2. A survey is carried out two months early. What is the effect under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (The next due date is still counted from the original anniversary, not postponed by the early survey)
💡 The SOLAS window allows flexibility in scheduling but does not change the due date, which is counted from the certificate anniversary. An early survey does not postpone the next one, preventing effective extension of the certificate by surveying early.
✗
Question 3. What must be done before a 406 MHz satellite EPIRB is brought into service?
Your Answer: (Not answered)
Correct Answer: C (Registered with the relevant authority with up-to-date information)
💡 406 MHz EPIRBs shall be registered with current information so that alerts can be verified and rescue coordinated.
✗
Question 4. Liferafts shall be stowed so that they:
Your Answer: (Not answered)
Correct Answer: A (float free automatically if the ship sinks before manual release)
💡 SOLAS III/13 requires liferafts to be stowed to float free automatically, using a hydrostatic release unit.
✗
Question 5. How do hinged and sliding watertight doors differ in use while the ship is at sea?
Your Answer: (Not answered)
Correct Answer: C (the hinged door shut before the ship leaves port and kept shut at sea, while a sliding door permitted to be used may be closed at any moment from the bridge and from either side)
💡 The line is drawn not by which way the door swings or how fast it shuts, but by whether it may be standing open at sea. A hinged door, open, leaves the bulkhead doing nothing, so it is to be shut before the ship parts from the port and kept shut on the voyage. A power slide sits where people must pass, so it is allowed to work at sea where permission covers it, on the terms that it can be closed at any moment from the bridge and from either side of it, that the closing has a sound and a indication, that lamps show where the door stands, that it is tested at intervals and written up, and that a document on board says which doors may be used at sea and when they must be closed, the master seeing it carried out before sailing. Whether the indication, the alarm and the local control work is a common thing to test in an inspection and in a drill; to treat it as long as somebody keeps an eye on it is the opposite of the requirement.
✗
Question 6. In which circumstances must the supply of inert gas to cargo tanks be stopped?
Your Answer: (Not answered)
Correct Answer: A (When the oxygen content of the gas exceeds the prescribed limit or the system fails)
💡 Where the oxygen content of the inert gas exceeds the limit or the system develops a fault, supply must be stopped and contingency measures taken. Otherwise gas with too much oxygen enters the tanks and defeats the inerting.
✗
Question 7. What may result from insufficient height of the hatch coaming?
Your Answer: (Not answered)
Correct Answer: B (Water shipping into the hold)
💡 The coaming height is set so that shipping or sea water cannot enter the hold.
✗
Question 8. What special life-saving appliance requirements apply in polar waters?
Your Answer: (Not answered)
Correct Answer: D (Measures to extend survival time, such as collective survival craft, thermal protection and search aids)
💡 The Polar Code requires life-saving appliances to address the need to extend survival time in polar regions, including collective survival craft of adequate capacity and thermal performance, ample thermal protective aids and equipment aiding detection by rescuers, such as radar reflectors, SARTs and locating devices, together with corresponding emergency supplies.
✗
Question 9. Which certificate shall a ship hold under the ISPS Code?
Your Answer: (Not answered)
Correct Answer: A (ISSC)
💡 The International Ship Security Certificate.
✗
Question 10. The scrubber in an inert gas system mainly functions to:
Your Answer: (Not answered)
Correct Answer: C (cool and purify the inert gas, removing sulphur compounds and water)
💡 SOLAS II-2/5 requires a scrubber to cool and purify the inert gas, removing sulphur dioxide and moisture.
✗
Question 11. What is the core risk that SOLAS and the IMSBC Code require attention to when handling high density bulk cargo?
Your Answer: (Not answered)
Correct Answer: A (Damage to the tank top or double bottom from excessive local concentrated loading)
💡 High density cargoes weigh heavily for their volume, and a poor sequence can overstress the tank top and double bottom, causing deformation or cracking. The approved sequence and strength limits must be followed.
✗
Question 12. What checking of the firefighting equipment list against the ship is required?
Your Answer: (Not answered)
Correct Answer: D (Periodically verify the list against what is actually on board, replacing anything missing and updating records)
💡 The ISM Code and SOLAS require periodic verification of the firefighting equipment list against what is actually on board, including extinguishers, firefighter's outfits, hoses and fittings, with anything missing, damaged or expired made good and the records updated, preventing a shortfall from being discovered only at an inspection.
✗
Question 13. A cargo ship is licensed for sea areas A1, A2 and A3. Equipment requirements stack by area; what does A3 add on top of A1 and A2?
Your Answer: (Not answered)
Correct Answer: A (either an Inmarsat ship earth station or high-frequency radio equipment, for alerting and for receiving maritime safety information)
💡 Area A3 lies outside A1 and A2, where geostationary satellite coverage holds but high-frequency alerting is not assured; the Convention allows either an Inmarsat ship earth station or high-frequency equipment, one being enough, with safety information taken by EGC or NAVTEX. Reading A3 as demanding both services at once, or as satisfied by an extra very-high-frequency set, is the usual mistake on the equipment list.
✗
Question 14. What is the purpose of the navigation light failure alarm?
Your Answer: (Not answered)
Correct Answer: C (To give an alarm on the bridge when a navigation light fails so that it can be detected and repaired promptly)
💡 Under SOLAS V/19 and related requirements navigation lights should be provided with a failure alarm which, on failure of a light or its circuit, gives an alarm on the bridge so that the watchkeeper can detect and repair it promptly, ensuring the lights can be relied on at night. The testing of the alarm should be kept effective.
✗
Question 15. What is the main purpose of establishing restricted areas under the ship security plan?
Your Answer: (Not answered)
Correct Answer: C (To prevent unauthorised access and the introduction of weapons or dangerous articles)
💡 ISPS Code Part A/10 requires restricted areas to be identified and controlled in order to prevent unauthorised access and the introduction of weapons or dangerous articles on board. Convenience of operations is not the purpose.
✗
Question 16. The deck water seal in a tanker inert gas system primarily serves to:
Your Answer: (Not answered)
Correct Answer: A (prevent cargo tank gas from flowing back into the machinery space)
💡 SOLAS II-2/5 requires a deck water seal to prevent backflow of cargo tank gas to the inert gas generator and machinery space.
✗
Question 17. What is the purpose of AIS?
Your Answer: (Not answered)
Correct Answer: B (Automatic broadcast and reception of ship identification and navigational information)
💡 To broadcast and receive ship identification and navigational information automatically.
✗
Question 18. What is the relationship between an extension and a short-term certificate?
Your Answer: (Not answered)
Correct Answer: B (An extension applies where a certificate expires during a voyage; a short-term certificate is issued to enable the ship to reach a port of survey or for another specific purpose)
💡 An extension under SOLAS is a remedy where a certificate expires during a voyage before survey can be carried out, while a short-term certificate is issued for a limited period to enable the ship to reach the port of survey or for another specific purpose. The situations differ and neither may replace the full certificate long term.
✗
Question 19. In what form shall the fire control plan be presented?
Your Answer: (Not answered)
Correct Answer: D (Plans, with symbols, showing divisions, control stations and fire-fighting appliances on each deck)
💡 Plans with standard symbols showing divisions, control stations and appliances on each deck.
✗
Question 20. When transiting a high-risk piracy area, which of the following is NOT among the measures recommended by Best Management Practices?
Your Answer: (Not answered)
Correct Answer: C (Switching off AIS and automatic identification to avoid being tracked)
💡 Best Management Practices recommend measures such as increasing speed and freeboard, fitting razor wire and physical barriers, providing and drilling a citadel, strengthening lookout and lighting, and reporting as required and reporting pirate activity. AIS should generally remain on, and switching it off may breach the rules and hinder search and rescue, so it is not a recommended measure.
✗
Question 21. Survival craft launching appliances shall be capable of being operated:
Your Answer: (Not answered)
Correct Answer: B (under unfavourable conditions of trim and list)
💡 SOLAS III/16 requires launching appliances to operate under unfavourable conditions of trim and list.
✗
Question 22. Before the ship proceeds to sea, the voyage plan shall be prepared by:
Your Answer: (Not answered)
Correct Answer: B (the master)
💡 SOLAS V/34: the voyage plan shall be prepared before departure by the master.
✗
Question 23. What does SOLAS address regarding zoning of fire detection systems?
Your Answer: (Not answered)
Correct Answer: C (The system must identify the section in which the alarm originated, enabling the fire to be located quickly)
💡 SOLAS requires fixed fire detection systems to be arranged in sections so that the alarm indicates the section or space in which it originated, enabling the watchkeeper to confirm the actual location and act quickly.
✗
Question 24. What reporting do SOLAS and the related rules require for ships carrying dangerous goods?
Your Answer: (Not answered)
Correct Answer: D (Report the class, quantity and location of the dangerous goods as required by the port State)
💡 SOLAS VII and the related rules require the ship to report the class, quantity and location on board of the dangerous goods as required by the port State, so that the port can respond promptly if an incident occurs.
✗
Question 25. What does SOLAS address regarding lighting and marking of survival craft stowage?
Your Answer: (Not answered)
Correct Answer: D (Lighting and markings at the stowage positions and embarkation stations, enabling identification and operation at night)
💡 SOLAS requires the stowage positions of survival craft and the embarkation stations to be provided with lighting and clear markings such as signs or reflective tape, enabling persons to find the boarding positions and appliances quickly at night or in dense smoke.
✗
Question 26. For tankers of 10 000 GT and above, the main steering gear shall consist of:
Your Answer: (Not answered)
Correct Answer: C (two power units capable of simultaneous operation)
💡 SOLAS II-1/29 requires tankers, chemical tankers and gas carriers of 10 000 GT and above to have two power units capable of simultaneous operation.
✗
Question 27. What reporting is required for a security incident?
Your Answer: (Not answered)
Correct Answer: A (Report at once under the procedure to the company, the Administration and the relevant parties, recording the circumstances)
💡 A security incident such as unauthorised boarding, the introduction of weapons, theft or sabotage requires immediate reporting under the ship security plan to the company, the Administration where necessary and the port facility security officer, recording the course of the incident, the action taken and the result, with analysis and improvement to follow.
✗
Question 28. Where shall the emergency generator and its fuel supply be located?
Your Answer: (Not answered)
Correct Answer: B (In a position not readily affected by main engine failure or fire)
💡 It must be sited away from the main engine and fire risk, with an independent fuel supply.
✗
Question 29. What does the Polar Code address regarding equipment for low temperature in polar waters?
Your Answer: (Not answered)
Correct Answer: A (Materials and operating temperatures of essential equipment must suit the low temperatures, preventing brittle fracture and failure)
💡 The Polar Code requires essential equipment, materials and systems of a ship in polar waters to be designed for low temperatures, preventing failure through brittle fracture of steel, increased viscosity of hydraulic oil or reduced battery capacity.
✗
Question 30. What certificate must a ship operating in polar waters carry?
Your Answer: (Not answered)
Correct Answer: C (A Polar Ship Certificate)
💡 SOLAS XIV/3 requires ships operating in polar waters to hold a Polar Ship Certificate attesting compliance with the relevant parts of the Polar Code.
✗
Question 31. When a vessel at sea receives a distress alert, what is the master's obligation?
Your Answer: (Not answered)
Correct Answer: A (To proceed as quickly as possible to assist persons in distress, there being an obligation to assist unless doing so would seriously endanger the vessel and persons on board)
💡 Under SOLAS V/33 and the international obligation to render assistance, a vessel in a position to assist, on receiving information about persons in distress, should proceed as quickly as possible to their assistance unless doing so would seriously endanger the vessel and those on board. It should also inform those concerned and maintain communication.
✗
Question 32. What shall fuel oil tank level gauging comply with?
Your Answer: (Not answered)
Correct Answer: A (Devices that do not endanger fire safety)
💡 Gauging shall not endanger fire safety; glass tube gauges are prohibited for such use.
✗
Question 33. To which tankers does the emergency towing arrangement requirement of SOLAS II-1/3-3 apply?
Your Answer: (Not answered)
Correct Answer: D (Oil tankers of 20000 tonnes deadweight and above)
💡 SOLAS II-1/3-3 requires oil tankers of 20000 tonnes deadweight and above to be fitted with an emergency towing arrangement at bow and stern, so that a disabled tanker can be taken in tow. It is not limited to new ships.
✗
Question 34. What is the most important requirement in the stowage and securing of a liferaft?
Your Answer: (Not answered)
Correct Answer: B (That it can be released very quickly)
💡 A liferaft must be capable of quick release; excessive chocking impedes access.
✗
Question 35. Sea area A1 means an area within the radiotelephone coverage of at least one:
Your Answer: (Not answered)
Correct Answer: A (VHF coast station with continuous alerting capability)
💡 SOLAS IV/2: Sea area A1 is the area within the radiotelephone coverage of at least one VHF coast station with continuous DSC alerting.
✗
Question 36. What is the master's responsibility under SOLAS V?
Your Answer: (Not answered)
Correct Answer: A (Ultimate responsibility for the safety of the ship and persons, which may not be assumed by others)
💡 The master bears ultimate responsibility for the safety of the ship and those on board.
✗
Question 37. What is the essential requirement of SOLAS II-2/9 for fire doors?
Your Answer: (Not answered)
Correct Answer: B (They must maintain the fire integrity of the division and close reliably in the event of fire)
💡 SOLAS II-2/9 requires fire doors to preserve the rating of the division and to close in a fire by self-closing means or remote control. Securing them permanently open is a common deficiency.
✗
Question 38. What does SOLAS address regarding the equipment of a rescue boat compared with a lifeboat?
Your Answer: (Not answered)
Correct Answer: D (A rescue boat must carry equipment suited to its task, such as a rescue quoit, buoyant lifeline and portable VHF)
💡 SOLAS requires a rescue boat to carry equipment suited to its task, including a rescue quoit with line, a buoyant lifeline for recovery, a portable VHF and similar items, enabling it to recover a person from the water quickly.
✗
Question 39. Which statement about the role of the NAVTEX receiver in sea areas A1 and A2 is correct?
Your Answer: (Not answered)
Correct Answer: D (It automatically receives and prints maritime safety information broadcast by coast stations in the area)
💡 NAVTEX is a receive-only device that automatically prints MSI such as navigational warnings and weather forecasts broadcast by coast stations on 518 kHz. It neither transmits alerts nor carries two-way traffic.
✗
Question 40. What expansion ratio is generally required for a tanker deck foam system?
Your Answer: (Not answered)
Correct Answer: C (Not exceeding about 12)
💡 The expansion ratio shall generally not exceed about 12.
✗
Question 41. What is the requirement for the total capacity of fire pumps?
Your Answer: (Not answered)
Correct Answer: A (It shall be sufficient to supply the required jets at the minimum pressure)
💡 Pumps shall supply the required jets at the prescribed minimum pressure.
✗
Question 42. What should be noted about steering gear in cold climates?
Your Answer: (Not answered)
Correct Answer: C (The increased oil viscosity and the effect of low temperature on pipes must be considered, with heating or low temperature oil as necessary)
💡 In cold climates the increased viscosity of the hydraulic oil slows the steering response and increases pressure loss in the piping. Oil suited to low temperature should be used as the maker requires, with heating where necessary, and the steering gear fully tested before sailing, preventing loss of steering in confined waters.
✗
Question 43. What is the total embarkation and launching time for survival craft on a passenger ship?
Your Answer: (Not answered)
Correct Answer: B (Not more than 30 minutes from the abandon ship signal)
💡 Within 30 minutes of the abandon ship signal.
✗
Question 44. Each lifeboat shall be launched during an abandon-ship drill at least every:
Your Answer: (Not answered)
Correct Answer: A (three months)
💡 SOLAS III/19 requires each lifeboat to be launched in a drill at least every three months.
✗
Question 45. What means should be used first for distress communication in sea area A4?
Your Answer: (Not answered)
Correct Answer: B (MF/HF equipment, DSC, radiotelephony and NBDP, trying several bands)
💡 Sea area A4 has no satellite or VHF coast station coverage, so distress communication should be attempted first on MF/HF equipment, including DSC alerting, radiotelephony distress calls and narrow-band direct printing telegraphy, trying several bands to establish contact with a coast station or another ship.
✗
Question 46. What do SOLAS and the related rules emphasise for position fixing in ice or polar waters?
Your Answer: (Not answered)
Correct Answer: A (Cross-check by several means, since compass and position fixing equipment may be affected by magnetic variation and signal conditions in polar regions)
💡 Magnetic variation is large in polar regions and satellite signals may be affected by ionospheric conditions. SOLAS and good seamanship require the position and heading to be cross-checked by several means, avoiding the risk from a single equipment error.
✗
Question 47. What time limits apply to work in an enclosed space?
Your Answer: (Not answered)
Correct Answer: D (Work according to the conditions and period in the permit, with re-testing and a new permit if the period expires or conditions change)
💡 SOLAS and the IMO resolutions require work in an enclosed space to be carried out under the conditions and for the period stated in the permit, with ventilation and testing maintained. If the permit period expires, ventilation is interrupted or conditions change, work must stop, the atmosphere be re-tested and a new permit issued.
✗
Question 48. What is the usual maximum validity of a Cargo Ship Safety Equipment Certificate?
Your Answer: (Not answered)
Correct Answer: D (Five years, with annual and periodical surveys)
💡 Under SOLAS I/12 the Cargo Ship Safety Equipment Certificate has a usual validity of not more than five years, with annual and periodical surveys within it. It remains valid only if the surveys are carried out and endorsed, the safety equipment provision and performance being the focus of the survey.
✗
Question 49. What is the starting requirement for the emergency generator under list and trim?
Your Answer: (Not answered)
Correct Answer: D (It must start automatically and supply the emergency load under the prescribed angles of list and trim)
💡 SOLAS requires the emergency generator to start automatically and carry the emergency load under the prescribed angles of list and trim. Since a ship is often listed after damage, the emergency source must be available in that condition.
✗
Question 50. What should be done if another vessel is not showing the required lights?
Your Answer: (Not answered)
Correct Answer: C (Navigate with particular caution, warn by VHF or light if necessary and act on the most probable assumption)
💡 If another vessel is not showing the prescribed lights or shapes, particular caution is required, as she may be a fishing vessel, not under command or have defective equipment. She should be warned by VHF or light if necessary and avoiding action taken on the most cautious assumption, preventing collision.
✗
Question 51. Which principle applies to the stowage of survival craft?
Your Answer: (Not answered)
Correct Answer: D (They must be readily available and capable of being launched and boarded rapidly and safely in an emergency)
💡 Under SOLAS III/13 survival craft should be stowed in a position where they are readily available and can be launched and boarded rapidly and safely, protected from the effects of fire and explosion, the arrangement of the craft and their launching and boarding appliances ensuring that in an emergency persons can muster, board and clear quickly.
✗
Question 52. A fixed fire detection and fire alarm system shall cover:
Your Answer: (Not answered)
Correct Answer: C (machinery spaces, accommodation spaces and control stations as specified)
💡 SOLAS II-2/7: a fixed fire detection and fire alarm system shall cover machinery spaces, accommodation spaces and control stations as specified.
✗
Question 53. What safety precautions apply when using a CO2 extinguisher?
Your Answer: (Not answered)
Correct Answer: A (Hold the insulated handle to avoid cold burns and leave a poorly ventilated space promptly after use to avoid asphyxiation)
💡 CO2 discharges at a very low temperature, so the insulated handle should be held to avoid cold burns. CO2 displaces oxygen, so after heavy use in a confined space personnel should leave promptly and the space be ventilated, avoiding asphyxiation.
✗
Question 54. What must be checked on board when loading containers under SOLAS and the CSS Code?
Your Answer: (Not answered)
Correct Answer: D (The weight, position and securing of containers, preventing structural damage or securing failure from overweight boxes)
💡 SOLAS VI/2 requires the declared weight of containers to be verified against actual weight and securing carried out in accordance with the securing manual. Overweight boxes or improper securing cause structural damage and loss of cargo overboard.
✗
Question 55. Which watertight doors may be used for passage during navigation?
Your Answer: (Not answered)
Correct Answer: A (Sliding watertight doors)
💡 Sliding watertight doors may be used during navigation; other watertight doors shall be kept closed.
✗
Question 56. The isolating valve on the fire main serving the accommodation side has long been seized and cannot be operated. How should this be judged?
Your Answer: (Not answered)
Correct Answer: D (Fire main isolating valves must be operable at all times; being seized is a deficiency affecting the isolating function)
💡 Isolating valves on the fire main are used to isolate a damaged section of piping so that the rest of the system still receives water. They must be capable of manual operation at all times. Being seized deprives them of their isolating function and is a deficiency affecting the reliability of the firefighting system, which should be rectified.
✗
Question 57. Portable fire extinguishers in machinery spaces shall be:
Your Answer: (Not answered)
Correct Answer: A (at least one near each hydrant and sufficient in total for the space)
💡 SOLAS II-2/10 requires at least one portable extinguisher near each hydrant, with sufficient total number.
✗
Question 58. What does SOLAS address regarding the location of the emergency fire pump?
Your Answer: (Not answered)
Correct Answer: A (Located outside the machinery space with independent power and a separate suction)
💡 SOLAS requires the emergency fire pump to be located outside category A machinery spaces with an independent source of power and a separate suction, so that it is not affected by a fire in that space and can draw water independently.
✗
Question 59. What time limits apply to launching and recovering a rescue boat?
Your Answer: (Not answered)
Correct Answer: B (Launching and recovery, when loaded, each within 5 minutes)
💡 Launching and recovery when fully loaded shall each be within 5 minutes.
✗
Question 60. What does the management element of a SIRE inspection normally cover?
Your Answer: (Not answered)
Correct Answer: D (Crew qualifications and training records, hours of work and rest and the conduct of safety meetings and training)
💡 The management element of a SIRE inspection normally covers the qualifications and certificates of competence of the crew, training and familiarisation records, records of hours of work and rest for fatigue management and the actual conduct of safety meetings and training, together with the crew's grasp of their own duties.
✗
Question 61. Which high risk areas do SOLAS and the ESP require to be examined on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Hatch covers, the internal structure of top side and hopper side tanks and the corrosion and cracking of bulkheads and side structure)
💡 The ESP and SOLAS require close-up examination and thickness measurement of hatch covers, the internal structure of top side and hopper side tanks and the stiffening of bulkheads and sides, since these areas corrode readily and directly affect the longitudinal strength of the hull.
✗
Question 62. What does SOLAS and the related rules address regarding cargo ventilation?
Your Answer: (Not answered)
Correct Answer: B (Ventilating appropriately according to the nature of the cargo, preventing self-heating, harmful gas accumulation or condensation damage)
💡 SOLAS and the IMSBC Code require the method and timing of ventilation to suit the cargo: some need ventilation to remove heat, others must not be ventilated to avoid moisture uptake or increased self-heating. Ventilating blindly may make matters worse.
✗
Question 63. When a ship changes flag, which is required?
Your Answer: (Not answered)
Correct Answer: D (Both the former and new flag States must recognise the ship's safety status)
💡 Flag change requires formal recognition of safety status by both the former and new flag States.
✗
Question 64. If the master finds a defect affecting safe navigation that cannot be repaired on board, the first action is to:
Your Answer: (Not answered)
Correct Answer: A (Report to the Company and arrange repair)
💡 The master should report to the Company so that repair can be arranged and the voyage adjusted.
✗
Question 65. How does the survival craft requirement for a passenger ship differ from that for a cargo ship?
Your Answer: (Not answered)
Correct Answer: A (Each side must accommodate all persons, with additional liferafts for a percentage of the total number of persons)
💡 SOLAS III/21 requires each side of a passenger ship to accommodate all persons on board, with additional liferafts for a percentage of the total number of persons, so that everyone can escape if one side is unavailable.
✗
Question 66. Why does SOLAS V/19.2.2 require a heading repeater at the steering position?
Your Answer: (Not answered)
Correct Answer: D (So that the helmsman can read the heading without leaving the steering position)
💡 SOLAS requires a heading repeater at the steering position so the helmsman can read the heading directly without leaving his station.
✗
Question 67. What is sea area A1?
Your Answer: (Not answered)
Correct Answer: D (An area within coverage of at least one VHF coast station)
💡 An area within coverage of at least one VHF coast station with DSC.
✗
Question 68. A cargo ship is 140 m in length with a crew of 20. What capacity must the survival craft on each side provide under SOLAS III/31?
Your Answer: (Not answered)
Correct Answer: D (Each side must accommodate all 20 persons on board)
💡 SOLAS III/31 requires the survival craft on each side of a cargo ship to accommodate all persons on board, so that everyone can escape whichever side is unusable. Counting the total for both sides only is not sufficient.
✗
Question 69. The navigation lights are found not to meet the required position, colour or arc of visibility. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Non-compliant navigation lights affect the ability of other ships to judge the situation, a deficiency to be corrected)
💡 The position, colour and arc of visibility of the navigation lights, such as masthead, sidelights and stern light, must meet the requirements so that other ships can judge the heading and movement of the vessel from the correct bearing and distance. Non-compliance may lead to misjudgement and increased risk of collision. It is a deficiency to be corrected.
✗
Question 70. What does SOLAS address regarding the watertight integrity of spaces above the bulkhead deck?
Your Answer: (Not answered)
Correct Answer: C (Openings must be fitted with effective closing appliances to prevent sea water entering the hull through them)
💡 SOLAS requires openings such as doors, side scuttles and ventilators above the bulkhead deck to have effective closing appliances, preventing sea water from entering the hull and causing loss of stability.
✗
Question 71. In what condition must a lifeboat be kept while stowed?
Your Answer: (Not answered)
Correct Answer: C (In a condition of immediate readiness for launching, with securing arrangements that can be released quickly without impairing safety)
💡 SOLAS requires a lifeboat when stowed to be ready for immediate launching: equipment complete on board, a gravity davit in a releasable condition and securing arrangements that hold the boat secure at sea yet can be released quickly in an emergency. Multiple lashings or dismantled parts would delay abandonment.
✗
Question 72. A certificate exempting a ship from certain convention requirements is called:
Your Answer: (Not answered)
Correct Answer: C (An Exemption Certificate)
💡 An Exemption Certificate is issued where special construction makes full compliance impracticable.
✗
Question 73. What should be done when a detection system alarms without an actual fire?
Your Answer: (Not answered)
Correct Answer: C (Establish the cause, such as a contaminated detector, a fault or a real latent hazard, and deal with it before resetting)
💡 When the cause of an alarm is unclear, it should be established whether a detector is contaminated, there is a circuit fault or a real latent hazard exists, such as concealed smouldering, and dealt with before resetting. Simply resetting or disabling the circuit conceals a real danger, a serious concern.
✗
Question 74. What does the ISPS Code list among the duties of the ship security officer?
Your Answer: (Not answered)
Correct Answer: C (Implementing the ship security plan, conducting security training and drills and reporting security incidents)
💡 ISPS Code Part A/14 makes the ship security officer responsible for implementing and maintaining the ship security plan, conducting training and drills, reporting security incidents and liaising with the port facility security officer.
✗
Question 75. Cargo tank hatch covers on a tanker shall:
Your Answer: (Not answered)
Correct Answer: C (be kept closed and prevent the escape of vapour when opened)
💡 SOLAS II-2/4 requires cargo tank hatches to be kept closed and to prevent vapour escape.
✗
Question 76. What communication procedure should be exercised in emergency steering drills?
Your Answer: (Not answered)
Correct Answer: D (Passing and confirming orders between the bridge and the steering gear compartment, ensuring communication works in an emergency)
💡 An emergency steering drill should include passing and repeating orders between the bridge and the steering gear compartment using the prescribed means, so that orders are accurate in an emergency. Practising the operation without the communication leaves a gap.
✗
Question 77. What do SOLAS and the ISM Code require after equipment failure at sea?
Your Answer: (Not answered)
Correct Answer: B (Record the failure and the action taken, report to the company and, where required, to the Administration)
💡 SOLAS and the ISM Code require failures affecting safety to be recorded, including the time, nature of the failure, action taken and result, reported to the company as required and, where necessary, to the Administration or port State, as a basis for the operation of the system and later repair.
✗
Question 78. What do the blind sector limitations of SOLAS V/22 principally concern?
Your Answer: (Not answered)
Correct Answer: A (The total arc and individual arcs of blind sectors ahead as seen from the conning position)
💡 SOLAS V/22 limits the number and total arc of blind sectors ahead from the conning position so that the look-out remains effective. It does not deal with radar shadows or window reflection.
✗
Question 79. What is required regarding propeller immersion in the ballast condition?
Your Answer: (Not answered)
Correct Answer: A (The propeller must be sufficiently immersed to avoid racing and vibration, adjusting the ballast distribution if necessary)
💡 In the ballast condition a suitable distribution of ballast should ensure sufficient immersion of the propeller, normally a certain proportion of its diameter, avoiding racing, vibration and cavitation damage, while keeping the forward draught and trim such that the rudder remains effective.
✗
Question 80. What is the principle of assessing stability from the rolling period at sea?
Your Answer: (Not answered)
Correct Answer: D (The rolling period corresponds to the initial metacentric height: a shorter period means excessive stability and a longer one may mean insufficient stability)
💡 The rolling period varies inversely with the square root of the initial metacentric height. A clearly shorter period indicates increased stability from cargo settling or flooding, while a markedly longer period may indicate reduced stability from cargo shifting upwards or flooding. It is a useful aid to judging changes in stability at sea.
✗
Question 81. What is the minimum number of radar transponders (SARTs) for a cargo ship of 500 gross tonnage and above?
Your Answer: (Not answered)
Correct Answer: D (Two, one on each side)
💡 Under SOLAS IV/7 a cargo ship of five hundred gross tonnage and above should carry at least two radar transponders, normally one on each side, so that one can be taken into the survival craft on either side during abandonment. The SART marks the distress position on the radar.
✗
Question 82. Who fixes the minimum safe manning document and how is it used on board?
Your Answer: (Not answered)
Correct Answer: A (settled and issued by the flag administration for the type of ship and the trade)
💡 The figure is the flag's to fix: taking the type of ship, her tonnage and machinery power, the trade she plies and her organisation, with the automation she carries, and following the international guidelines on the subject, the administration settles the least number and the grades needed and sends the document to the ship. She is then manned to it, and those actually on board are not below what it asks; if the two disagree the discrepancy is a deficiency however the work is being done. The port State does not as a rule substitute its own calculation, but where it judges the people on board too few or too untalented for her ordinary and emergency working it may consult the flag. To give the number to the society or to leave it with the company crosses a line: the society surveys hull, machinery and equipment, and what the ship costs to man cannot change the least she needs.
✗
Question 83. What do SOLAS and good practice require of the electrical system after a fire?
Your Answer: (Not answered)
Correct Answer: A (Assess the circuits and equipment affected, isolate the faulty part and prioritise supply to emergency and firefighting equipment)
💡 After a fire the circuits affected should be assessed, the faulty part isolated and priority given to supplying emergency lighting, fire pumps and communications, preventing secondary incidents from short circuits or water. Cutting all power would defeat firefighting and evacuation.
✗
Question 84. What does SOLAS require regarding the establishment of safe working practices on board?
Your Answer: (Not answered)
Correct Answer: D (Appropriate systems and procedures must be established and followed so that personnel perform their duties to a consistent standard)
💡 SOLAS V/14 requires systems and procedures for safe working practices, covering bridge procedures, anchor watch, machinery operation and emergency procedures, ensuring consistent and safe operation.
✗
Question 85. What is required for cleaning the galley range hood and exhaust duct?
Your Answer: (Not answered)
Correct Answer: B (Periodic cleaning of grease deposits, preventing accumulated oil from being ignited by heat)
💡 Grease accumulating in a galley hood and exhaust duct is readily ignited by high temperature or flame, so thorough periodic cleaning is required, with the nozzles of the fixed extinguishing system checked for grease blockage. This is a common cause of galley fires.
✗
Question 86. What loading limitation must be observed when a bulk carrier loads high density cargo?
Your Answer: (Not answered)
Correct Answer: D (Limits on the maximum weight in each hold and on differences between adjacent holds, preventing excessive local stresses)
💡 Concentrated high density cargo overstresses the tank top and double bottom. SOLAS and the IMSBC Code require limits on the maximum weight per hold and on differences between adjacent holds to be observed. Limiting deadweight alone does not protect the structure.
✗
Question 87. What has to appear on the fire control plan?
Your Answer: (Not answered)
Correct Answer: C (the layout of each deck, the fire divisions and where the detecting and extinguishing gear stands, the whole agreeing with what is there)
💡 The plan is written for the people coming to fight the fire, so it must answer where to get in, what will stop the fire spreading, with what it is to be attacked and how to get out: the decks as arranged and numbered, the boundaries of class A and class B divisions and the fire zones they make, the doors and the dampers, the detection and the alarm, the systems and the appliances with where each stands, the ventilators and the means of closing them, and the ways of escape. It is made of durable material, agrees with the ship as she now is, and is altered when she is altered; a copy stands outside the bridge for the shore brigade and a copy is kept with the company. Hence marking only the extinguishers, the company settling the style, or a general arrangement drawing in place of it all fail - that drawing carries no line of fire division, no detection or extinguishing gear, and is not revised with the work. Each note on the plan is compared with the thing itself, and the commonest finding is the change that was made without the plan being changed.
✗
Question 88. The purpose of the Bridge Navigational Watch Alarm System (BNWAS) is to:
Your Answer: (Not answered)
Correct Answer: D (monitor the activity of the officer of the watch and raise an alarm if incapacitated)
💡 SOLAS V/19: a BNWAS monitors the activity of the officer of the watch and raises an alarm if he is incapacitated.
✗
Question 89. How many means of escape are required on each deck in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: A (At least two, widely separated)
💡 At least two widely separated means of escape per deck.
✗
Question 90. What is the usual maximum validity of a Cargo Ship Safety Radio Certificate?
Your Answer: (Not answered)
Correct Answer: B (Five years, with periodical surveys)
💡 Under SOLAS I/12 the Cargo Ship Safety Radio Certificate has a usual validity of not more than five years, with periodical surveys as required. The performance and provision of the radio installation, including distress alerting, communications and the reserve source of energy, are the focus of the survey.
✗
Question 91. What is the cycle for safety management system audits?
Your Answer: (Not answered)
Correct Answer: D (Internal audits normally not exceeding 12 months, annual verification of the DOC and intermediate verification of the SMC)
💡 The ISM Code requires internal audits at intervals not exceeding 12 months, annual verification of the Document of Compliance to keep it valid and intermediate verification of the Safety Management Certificate within its period of validity. Failure to verify in time affects the validity of the certificates.
✗
Question 92. On which primary frequency does NAVTEX broadcast navigational and meteorological warnings?
Your Answer: (Not answered)
Correct Answer: B (518 kHz)
💡 NAVTEX broadcasts on 518 kHz, with 490 kHz as the backup frequency.
✗
Question 93. Which ships must carry an automatic identification system under the Convention?
Your Answer: (Not answered)
Correct Answer: A (passenger ships of any size, cargo ships of three hundred gross tonnage and upwards on international voyages, cargo ships of five hundred gross tonnage and upwards not so engaged, and mobile offshore drilling units)
💡 The requirement is written by ship type. Passenger ships carry it whatever their size. Of cargo ships, those of three hundred gross tonnage and upwards engaged on international voyages and those of five hundred gross tonnage and upwards not so engaged are to be fitted within the dates the Regulation gives, and mobile offshore drilling units are named with them. To say "every ship of three hundred tons on an international voyage" therefore claims too much: a cargo ship between three hundred and four hundred and ninety-nine tons trading domestically is outside the Regulation, and whether a voyage is international is for the flag administration. Nothing turns on whether the ship carries an electronic chart, and nothing turns on her radar; the text looks at type, tonnage and the trading area.
✗
Question 94. If a ship fails a survey because of an equipment deficiency, what may the Administration do?
Your Answer: (Not answered)
Correct Answer: B (Require rectification within a period and re-inspect afterwards, with the validity of the certificate possibly affected meanwhile)
💡 SOLAS I/12 permits the Administration to suspend or withdraw a certificate where the ship does not comply. In practice rectification within a period and re-inspection is required before validity is maintained or restored. A certificate must not be issued with a deficiency outstanding.
✗
Question 95. Where shall the emergency fire pump required by SOLAS be located?
Your Answer: (Not answered)
Correct Answer: C (Outside the machinery space)
💡 The emergency fire pump must be located outside the machinery space so that it remains available if that space is on fire.
✗
Question 96. When peak and deep tanks are used as ballast tanks, what does SOLAS II-1 require of the ballast system?
Your Answer: (Not answered)
Correct Answer: B (It must be capable of safely filling and emptying ballast tanks under all operating conditions)
💡 SOLAS II-1 requires the ballast system to fill and empty tanks safely under all operating conditions so that draught and stability can be controlled. It is not confined to port use.
✗
Question 97. What should be checked about the type approval marking of life-saving appliances?
Your Answer: (Not answered)
Correct Answer: C (That the appliance bears the approval marking or certificate number of the Administration or a recognised body)
💡 SOLAS and the LSA Code require life-saving appliances to be type approved and to bear the approval marking or certificate number. On inspection the marking should be clear and consistent with the certificate. Appliances without an approval mark may not be accepted by the surveyor or the PSC, and are a deficiency.
✗
Question 98. What does SOLAS require regarding the drive of fire pumps?
Your Answer: (Not answered)
Correct Answer: A (Each fire pump must be driven by an independent prime mover, so a single failure does not put all pumps out of action)
💡 SOLAS requires fire pumps to be independently driven, so that failure of the power supply or prime mover of one pump does not disable the others, ensuring an alternative pump remains available.
✗
Question 99. What do SOLAS and the Load Line Convention address regarding the height of coamings at openings in the freeboard deck?
Your Answer: (Not answered)
Correct Answer: A (Coamings must reach the prescribed height to prevent sea water entering spaces below)
💡 SOLAS and the Load Line Convention require openings in the freeboard deck leading to spaces below to have coamings of the prescribed height with effective closing appliances, preventing water shipped on deck from entering and affecting stability.
✗
Question 100. The officer of the watch sees a man fall overboard off the starboard side. What is the first action?
Your Answer: (Not answered)
Correct Answer: A (turning at once towards the person to get back quickly, the lifebuoy with its self-lighting smoke gone, the man-overboard alarm sounded)
💡 The first business is to get the ship back to the water he went in: turning towards him keeps him clear of the screws and shortens the return — the Anderson turn is quickest in good visibility, the Williamson turn brings the ship back along her own track by night or in fog. The lifebuoy with its light and smoke marks the spot, three long blasts give the man-overboard alarm, VHF carries the ship's intentions, and the muster list sets the look-out and the boat. Stopping the ship, or reporting before manoeuvring, throws away the minutes in which recovery is still possible.