Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. Means of escape shall:
Your Answer: (Not answered)
Correct Answer: D (be continuous to the embarkation deck or muster station)
💡 SOLAS II-2/13 requires continuous means of escape to the embarkation deck or muster station.
✗
Question 2. The main functions of an Inmarsat ship earth station include:
Your Answer: (Not answered)
Correct Answer: C (distress alerting, communication and reception of maritime safety information)
💡 SOLAS IV/7 requires an Inmarsat ship earth station for distress alerting, communication and reception of MSI.
✗
Question 3. The ISPS Code applies to:
Your Answer: (Not answered)
Correct Answer: A (passenger ships and cargo ships of 500 GT and above engaged on international voyages)
💡 SOLAS XI-2/3: the ISPS Code applies to passenger ships and cargo ships of 500 GT and above engaged on international voyages.
✗
Question 4. Which high risk areas do SOLAS and the ESP require to be examined on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Hatch covers, the internal structure of top side and hopper side tanks and the corrosion and cracking of bulkheads and side structure)
💡 The ESP and SOLAS require close-up examination and thickness measurement of hatch covers, the internal structure of top side and hopper side tanks and the stiffening of bulkheads and sides, since these areas corrode readily and directly affect the longitudinal strength of the hull.
✗
Question 5. What shall be done if radio equipment fails?
Your Answer: (Not answered)
Correct Answer: D (Repair it as soon as practicable and report as required)
💡 It shall be repaired as soon as practicable and reported as required.
✗
Question 6. What is required for the availability of the emergency source of power in flooding or fire?
Your Answer: (Not answered)
Correct Answer: D (It must be located where it is not directly affected by such casualties and be capable of independent supply)
💡 SOLAS requires the emergency source to be located outside category A machinery spaces, such as on the poop deck, with an independent fuel or power supply, so that it remains available when the machinery space is on fire or flooded.
✗
Question 7. Where a fixed pressure water-spraying system is fitted in a machinery space, its nozzles shall cover:
Your Answer: (Not answered)
Correct Answer: B (all areas of the machinery space where fire may occur)
💡 SOLAS II-2/10 requires the fixed pressure water-spraying system to cover all areas of the machinery space where fire may occur.
✗
Question 8. What is required regarding the order of abandonment when passengers are on board?
Your Answer: (Not answered)
Correct Answer: B (Passengers organised to leave first under the prepared procedure, with crew guiding, assisting boarding and handling the craft, the master leaving last)
💡 SOLAS requires passengers to be evacuated first in an orderly way under the prepared procedure on a passenger ship, with the crew guiding, assisting with boarding and handling the craft and the master leaving last. The crew leaving first or disorder would cause heavy casualties.
✗
Question 9. Emergency lighting batteries are found of insufficient capacity so that the lights cannot last the required time after a power failure. The finding is?
Your Answer: (Not answered)
Correct Answer: A (Emergency lighting cannot last the required duration, a deficiency affecting escape and operational safety)
💡 Emergency lighting, including the emergency source of power, must last the required duration after the main power fails so as to light escape routes, muster stations, engine room escapes and essential operations. Insufficient capacity defeats this function and is a deficiency to be corrected.
✗
Question 10. In heavy weather, which decision should the master give priority to?
Your Answer: (Not answered)
Correct Answer: B (Reducing speed to lessen rolling in a beam sea)
💡 A beam sea increases rolling and endangers cargo and hull strength; speed should be reduced.
✗
Question 11. What does SOLAS require regarding the scenarios used in fire drills?
Your Answer: (Not answered)
Correct Answer: C (Scenarios should be planned to reflect the different situations realistically possible, avoiding the same assumption each time)
💡 SOLAS and good practice require fire drill scenarios to be based on the actual risk assessment and to vary, such as fires in the machinery space, a cargo hold or different parts of the accommodation. Always using the same scenario leaves the crew unprepared for the real event.
✗
Question 12. Before hot work in the cargo tank area of a tanker, what must be done under SOLAS and related guidance?
Your Answer: (Not answered)
Correct Answer: D (Gas testing, a hot work permit, removal of combustibles and firefighting standby precautions)
💡 SOLAS and ISGOTT require gas testing, removal of combustible material, a hot work permit and firefighting standby before hot work in a tanker's cargo area. None of these steps may be omitted.
✗
Question 13. Within an emission control area, what is the sulphur limit of fuel oil used on board?
Your Answer: (Not answered)
Correct Answer: A (0.10 per cent m/m)
💡 Within an emission control area the sulphur limit of fuel oil used on board is 0.10 per cent m/m. The ship should be able to show compliance through bunker delivery notes, changeover procedures and records, and should allow sufficient changeover time before entering the area.
✗
Question 14. How is the rated capacity of survival craft determined under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (From the volume and floor area required per person and the design capacity of the craft)
💡 SOLAS prescribes the method of determining the rated capacity of survival craft, based on the minimum volume and floor area per person and the buoyancy and strength of the craft. Carrying more than the rated capacity seriously affects buoyancy and stability.
✗
Question 15. Life-saving appliances are kept on a planned maintenance schedule. How are the weekly and monthly checks divided?
Your Answer: (Not answered)
Correct Answer: C (weekly testing of the general alarm and of lighting at muster and embarkation stations, monthly examination of all appliances with their equipment confirmed complete and recorded)
💡 The Convention separates the two by object: weekly, the general emergency alarm system and the emergency lighting at muster and embarkation stations are tested; monthly, all life-saving appliances are examined, boats, rafts, their equipment, launching arrangements and engines being confirmed ready for immediate use, with defects logged. Shrinking the monthly check to one pass before the annual survey, or leaving rafts out of the ship's duties, is how equipment turns up missing when it is wanted.
✗
Question 16. What testing do fire pumps require in port?
Your Answer: (Not answered)
Correct Answer: A (Periodic testing of starting, discharge and pressure with records kept)
💡 SOLAS and good practice require periodic testing of fire pumps, including the method of starting, the discharge and whether the pressure meets the requirement, with the results recorded, keeping the system serviceable. Long neglect means a pump may not start when actually needed.
✗
Question 17. What is required when checking the lighting at survival craft embarkation positions?
Your Answer: (Not answered)
Correct Answer: A (Confirm that the emergency lighting operates, covering the embarkation area and the water alongside)
💡 SOLAS requires the lighting of the embarkation stations, survival craft stowage positions and the water alongside, including emergency lighting, to be confirmed in working order and covering the required area, so that abandonment at night is adequately lit. An appearance check would not confirm availability during a blackout.
✗
Question 18. The bow structure requirements for bulk carriers mainly address:
Your Answer: (Not answered)
Correct Answer: B (carriage of high-density solid bulk cargoes such as ore)
💡 SOLAS XII/9: the bow structure requirements address the carriage of high-density solid bulk cargoes such as ore.
✗
Question 19. A ship is to load a concentrate liable to liquefy. Under SOLAS VI/1 which two key data must the shipper provide to the master before loading?
Your Answer: (Not answered)
Correct Answer: B (The moisture content and the transportable moisture limit (TML))
💡 SOLAS VI/1 and the IMSBC Code require the moisture content and the TML to be provided before loading. The cargo may be accepted only when the moisture content is below the TML; weight alone gives no indication of liquefaction risk.
✗
Question 20. What does SOLAS address regarding the relationship between survey intervals and the validity of certificates?
Your Answer: (Not answered)
Correct Answer: B (The validity period corresponds to the survey cycle, and failure to survey in time makes the certificate invalid)
💡 SOLAS links the survey cycle to the validity of the certificate: the initial, annual or intermediate and renewal surveys are the conditions for maintaining validity. Failure to carry out any of them in time affects the validity of the certificate.
✗
Question 21. What is required for monitoring deviation from the planned route?
Your Answer: (Not answered)
Correct Answer: B (Check the position against the planned route regularly, correcting any deviation promptly and recording the reason)
💡 During the voyage the position should be checked regularly against the planned route, together with the course and speed, with the cause of any deviation, such as wind and current set or a steering error, established and corrected at once, analysing the trend where necessary to prevent continuing offset leading to grounding.
✗
Question 22. A survey is carried out two months early. What is the effect under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (The next due date is still counted from the original anniversary, not postponed by the early survey)
💡 The SOLAS window allows flexibility in scheduling but does not change the due date, which is counted from the certificate anniversary. An early survey does not postpone the next one, preventing effective extension of the certificate by surveying early.
✗
Question 23. What interval applies to launching lifeboats into the water during drills on a cargo ship?
Your Answer: (Not answered)
Correct Answer: C (At least once every three months the boat is lowered into the water and manoeuvred, where reasonable and practicable)
💡 SOLAS III/19 requires a launching drill at least every three months and, where reasonable and practicable, the boat to be lowered into the water and manoeuvred at least once in that period, so that the crew acquires practical skill.
✗
Question 24. What should the crew do after the abandon ship alarm is sounded?
Your Answer: (Not answered)
Correct Answer: A (Act in accordance with the duties in the muster list, taking the designated items to the muster station and awaiting orders)
💡 On the abandon ship alarm the crew acts under the muster list: taking the designated emergency items such as lifejackets, certificates and the log and reporting to the muster station, with the master or the officer in charge deciding whether to abandon and the order of boarding. No one acts independently.
✗
Question 25. When must lock-out tag-out measures be applied?
Your Answer: (Not answered)
Correct Answer: D (When maintaining equipment that could cause injury if inadvertently started or operated)
💡 Lock-out tag-out measures, isolating the energy source, tagging and if necessary locking, should be applied to equipment maintenance where inadvertent starting, energising or opening of a valve could injure someone, preventing the equipment or medium from being brought into action while work is in progress.
✗
Question 26. Why does SOLAS V/19.2.2 require a heading repeater at the steering position?
Your Answer: (Not answered)
Correct Answer: D (So that the helmsman can read the heading without leaving the steering position)
💡 SOLAS requires a heading repeater at the steering position so the helmsman can read the heading directly without leaving his station.
✗
Question 27. What is the basic requirement for navigation lights used at night or in restricted visibility?
Your Answer: (Not answered)
Correct Answer: B (They must be displayed in accordance with the requirements, with indicators or failure alarms on the bridge)
💡 SOLAS V/19 requires navigation lights to comply with COLREG and to have indicators or failure alarms on the bridge, so that the ship can be identified at night and in restricted visibility.
✗
Question 28. When navigating in restricted visibility, what is required for look-out under SOLAS V and COLREG?
Your Answer: (Not answered)
Correct Answer: B (A proper look-out by sight and hearing as well as by radar, with an additional look-out posted forward)
💡 A proper look-out uses sight, hearing and radar together. In restricted visibility an additional look-out should be posted forward and a listening watch maintained. Radar does not replace the human look-out.
✗
Question 29. What principle should the officer of the watch follow in using ECDIS in confined waters or a port approach?
Your Answer: (Not answered)
Correct Answer: B (Adjust the display scale appropriately and keep the chart updated, avoiding over-reliance on a single display for position)
💡 ECDIS should be used with the scale adjusted to the leg of the passage, charts kept updated and the position cross-checked. Switching off safety alarms or fixing one scale weakens the warning function and increases the risk of grounding.
✗
Question 30. The securing of cargo units such as containers shall be carried out in accordance with:
Your Answer: (Not answered)
Correct Answer: A (the approved Cargo Securing Manual)
💡 SOLAS VI/5 requires securing of cargo units in accordance with the approved Cargo Securing Manual.
✗
Question 31. A PSC inspection found escape routes from accommodation to the embarkation station obstructed by stores. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (Escape routes must be kept clear and unobstructed; any obstruction is a deficiency)
💡 SOLAS II-2/13 requires means of escape to be kept clear and usable at all times. Any stowage or obstruction could cause casualties during an emergency evacuation and is a serious deficiency.
✗
Question 32. For a ship with periodically unattended machinery spaces, what does SOLAS require regarding alarms?
Your Answer: (Not answered)
Correct Answer: A (An alarm system automatically transmitting alarms to the bridge or the engineers' accommodation)
💡 A ship with periodically unattended machinery spaces must have an alarm system that automatically transmits machinery faults and abnormalities to the bridge or the engineers' accommodation, ensuring safe operation without attendance.
✗
Question 33. A cargo ship of 85 m in length is equipping lifebuoys. Under SOLAS III/7.1, what is the minimum number required?
Your Answer: (Not answered)
Correct Answer: A (12)
💡 SOLAS III/7.1 sets bands by length: under 60 m — 8; 60 m and under 120 m — 12; 120 m and under 180 m — 18; 180 m and above — 24. At 85 m the second band applies.
✗
Question 34. What does SOLAS require of the water ingress detection and alarm system on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: B (Detection in cargo holds, ballast tanks and dry spaces, with an audible and visual alarm on the bridge)
💡 SOLAS XII/12 requires a bulk carrier to have water ingress detection in cargo holds, ballast tanks and dry spaces, with an audible and visual alarm on the bridge, enabling the watchkeeper to detect flooding promptly and act.
✗
Question 35. What does the ISM Code emphasise about the company's responsibility?
Your Answer: (Not answered)
Correct Answer: A (The company has overall responsibility for the safety and pollution prevention management of its ships and must provide resources and support)
💡 The ISM Code emphasises that the company bears overall responsibility for the safety and pollution prevention management of its ships and must provide the necessary resources, personnel, equipment, training and shore support, and must not shift that responsibility to the master or the crew.
✗
Question 36. What does SOLAS require for the use of the echo sounder in shoal water?
Your Answer: (Not answered)
Correct Answer: A (It must give a continuous depth reading and be capable of an alarm at a preset safety depth)
💡 SOLAS requires the echo sounder to provide a continuous depth reading and to be capable of an alarm at a preset safety depth, enabling the officer to detect approaching shoal water in good time. A hand lead is not a substitute.
✗
Question 37. What is the required capacity of the main source of electrical power?
Your Answer: (Not answered)
Correct Answer: D (It must be capable of supplying all services necessary to maintain the ship in normal operational and habitable conditions)
💡 SOLAS II-1/40 requires the main source to supply all services necessary for normal operation and habitability, including propulsion auxiliaries, lighting, ventilation and communications.
✗
Question 38. What does SOLAS address regarding drawings and documents to be kept on board?
Your Answer: (Not answered)
Correct Answer: A (Approved drawings and information must be kept on board for inspection and use)
💡 SOLAS requires approved drawings and technical information such as stability information, fire control plans and cargo securing manuals to be kept on board for use by the crew and verification at surveys. Missing drawings prevent correct operation or survey.
✗
Question 39. What does SOLAS address regarding the protection of stairway enclosures?
Your Answer: (Not answered)
Correct Answer: D (Stairways must be enclosed by class A or B divisions, preventing a chimney effect from accelerating fire and smoke spread)
💡 SOLAS requires enclosed stairways in accommodation spaces to be protected by class A or B divisions, preventing the stairwell from acting as a chimney that accelerates the upward spread of flame and smoke, and protecting the escape route.
✗
Question 40. Radio antennas shall be so installed that they can operate:
Your Answer: (Not answered)
Correct Answer: A (under all weather conditions with adequate protection)
💡 SOLAS IV/13 requires radio antennas to operate under all weather conditions with adequate protection.
✗
Question 41. What is required of machinery space fans in a fire?
Your Answer: (Not answered)
Correct Answer: A (Capable of being stopped promptly and ventilation closed from outside)
💡 Fans shall be capable of prompt stopping and ventilation closed from outside.
✗
Question 42. Each ship shall carry at least how many sets of firefighter's outfits?
Your Answer: (Not answered)
Correct Answer: C (2)
💡 SOLAS II-2/10: each ship shall carry at least two sets of firefighter's outfits.
✗
Question 43. The Ship Security Plan shall be approved by:
Your Answer: (Not answered)
Correct Answer: A (the Administration or a recognised security organisation on its behalf)
💡 SOLAS XI-2/3: the Ship Security Plan shall be approved by the Administration or a recognised security organisation on its behalf.
✗
Question 44. What does SOLAS address regarding the construction of side doors and cargo doors in the shell?
Your Answer: (Not answered)
Correct Answer: C (They must be of strength equivalent to the adjacent hull with reliable closing appliances, included in survey and records)
💡 SOLAS requires shell doors and cargo doors in a cargo ship to have strength and watertightness equivalent to the adjacent hull, with reliable closing appliances, and to be included in periodic survey and maintenance records, since such openings are a high risk point for flooding.
✗
Question 45. Which is the MF digital selective calling distress frequency?
Your Answer: (Not answered)
Correct Answer: A (2187.5 kHz)
💡 2187.5 kHz is the MF DSC distress frequency; 2182 kHz is the MF radiotelephony distress frequency.
✗
Question 46. What is required for coordinating mooring lines and tugs when unberthing?
Your Answer: (Not answered)
Correct Answer: D (Slack and let go the lines in the proper order while maintaining communication with tugs and the terminal, preventing lines from fouling the propeller)
💡 Lines should be let go in the proper order, normally the spring and breast lines first and the head and stern lines last, with communication maintained with the tugs and the terminal, preventing slack lines from being taken into the propeller and damaging the propulsion system.
✗
Question 47. What are the usual transmit power settings of a ship's VHF radiotelephone?
Your Answer: (Not answered)
Correct Answer: A (1 watt (low) and 25 watts (high))
💡 A ship's VHF normally has two settings, one watt for low power and twenty-five watts for high power, low power being used for short-range communication to reduce interference and high power for long range or distress communication to ensure coverage. Selecting the right setting is a basic watchkeeping requirement.
✗
Question 48. What is a category A ship under the Polar Code?
Your Answer: (Not answered)
Correct Answer: B (A ship designed for operation in polar waters in at least medium first-year ice, possibly including old ice inclusions)
💡 The Polar Code categorises ships by ice capability: category A for at least medium first-year ice possibly with old ice inclusions, B for thin first-year ice, and C for open water or ice conditions lighter than A and B.
✗
Question 49. What should be done if oil overflows during bunkering?
Your Answer: (Not answered)
Correct Answer: C (Stop the operation at once, take emergency measures to contain the spill and prevent it entering the water)
💡 On overflow during bunkering the operation should be stopped at once by the agreed signal and emergency measures taken, such as absorbents and booms, with the spill collected and reported as required. Continuing would increase the quantity spilled and create pollution and fire risk.
✗
Question 50. Which statement about the inspection and maintenance of davits is correct?
Your Answer: (Not answered)
Correct Answer: A (Their structure, sheaves, wire ropes and braking arrangements should be inspected regularly to ensure reliable launching with the boat at its permitted complement)
💡 Under SOLAS III/4 and related requirements davits and their launching appliances should be inspected regularly for structural integrity, the condition of the sheaves and wire ropes, the braking and limit arrangements and whether the boat can be launched reliably with its permitted complement. Inspection and maintenance records should be kept and defects rectified promptly.
✗
Question 51. What is the maximum interval between ship security drills required by the ISPS Code?
Your Answer: (Not answered)
Correct Answer: C (Three months)
💡 ISPS Code Part A/13 and SOLAS XI-2 require ship security drills at intervals of not more than three months, with additional drills where the security level changes.
✗
Question 52. How many security levels are established under the ISPS Code?
Your Answer: (Not answered)
Correct Answer: A (Three)
💡 The ISPS Code establishes three security levels: 1, 2 and 3.
✗
Question 53. How many SARTs must a ship normally carry under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Two, normally sited on either side of the bridge for rapid access)
💡 SOLAS IV/7 requires two SARTs on cargo ships of 300 GT and above, normally sited on either side of the bridge for rapid access. A single SART cannot serve rescuing vessels approaching from either side.
✗
Question 54. In what circumstances must the master take over the conning of the ship?
Your Answer: (Not answered)
Correct Answer: D (Whenever the master judges that conditions or circumstances require him to take over personally)
💡 Under STCW and SOLAS, the master takes over whenever he considers it necessary, such as in narrow channels, dense traffic, heavy weather, restricted visibility or when berthing. It is his judgement.
✗
Question 55. What is the scope of the term 'ship' in SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Any ship engaged on international voyages, with exclusions such as warships and some small cargo ships)
💡 SOLAS applies to ships on international voyages, with stated exclusions for warships and certain small cargo ships.
✗
Question 56. Indication of propeller pitch and speed shall show:
Your Answer: (Not answered)
Correct Answer: B (pitch (where applicable), propeller speed and direction of rotation)
💡 SOLAS V/19: the bridge shall be provided with indicators for pitch (where applicable), propeller speed and direction of rotation.
✗
Question 57. In restricted visibility, which measure is NOT in accordance with SOLAS?
Your Answer: (Not answered)
Correct Answer: D (accelerate to pass through quickly)
💡 SOLAS V/8: in restricted visibility measures such as reducing speed, using radar and keeping a proper lookout shall be taken; accelerating is not permitted.
✗
Question 58. In which circumstances must the supply of inert gas to cargo tanks be stopped?
Your Answer: (Not answered)
Correct Answer: A (When the oxygen content of the gas exceeds the prescribed limit or the system fails)
💡 Where the oxygen content of the inert gas exceeds the limit or the system develops a fault, supply must be stopped and contingency measures taken. Otherwise gas with too much oxygen enters the tanks and defeats the inerting.
✗
Question 59. Cargo ships of 1 000 GT and above shall be provided with at least how many independently driven fire pumps?
Your Answer: (Not answered)
Correct Answer: D (2)
💡 SOLAS II-2/10 requires at least two independently driven fire pumps for cargo ships of 1 000 GT and above.
✗
Question 60. Surveys required for ships include:
Your Answer: (Not answered)
Correct Answer: C (initial, renewal, intermediate, annual and additional surveys)
💡 SOLAS I/6: surveys include initial, renewal, intermediate, annual and additional surveys.
✗
Question 61. What is meant by permeability in the subdivision calculation?
Your Answer: (Not answered)
Correct Answer: D (The proportion of the volume of a space that can be occupied by water)
💡 Permeability is the proportion of the volume of a space that can be occupied by water after damage. Its value differs for machinery spaces, accommodation and cargo spaces, and directly affects the volume of water entering and the calculation of residual stability.
✗
Question 62. Which factors must be considered in determining a safe speed under COLREG and SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Visibility, traffic density, manoeuvrability, background lights and weather conditions, among others)
💡 COLREG Rule 6 requires a safe speed to be determined with regard to visibility, traffic density, manoeuvrability, background lights and weather and sea state. Power or passage length alone is not a basis.
✗
Question 63. Under what conditions must machinery operate according to the relevant SOLAS provisions on list and trim?
Your Answer: (Not answered)
Correct Answer: A (It must operate normally under the prescribed angles of heel, trim and rolling)
💡 SOLAS requires main and auxiliary machinery and emergency equipment to operate normally under the prescribed angles of heel, trim and rolling, ensuring power and emergency capability in heavy weather.
✗
Question 64. Which system, directly related to fire protection, is required in accommodation and service spaces?
Your Answer: (Not answered)
Correct Answer: B (Fixed fire detection and alarm system)
💡 SOLAS II-2/12 requires fixed fire detection and alarm systems in accommodation and service spaces.
✗
Question 65. If unable to assist, the master receiving a distress alert shall:
Your Answer: (Not answered)
Correct Answer: D (Endeavour to relay the alert to units able to assist)
💡 Endeavour to relay the alert to units able to render assistance.
✗
Question 66. What should be done if the watertight door indicator fails?
Your Answer: (Not answered)
Correct Answer: B (Repair promptly; pending repair, increase rounds or take alternative measures and record them)
💡 The indicator is an important means of maintaining watertight integrity and should be repaired promptly. Where immediate repair is not possible, additional rounds or alternative measures should be taken and recorded, since without the indication the response to damage would be delayed.
✗
Question 67. What limitation must the officer of the watch bear in mind when using ARPA?
Your Answer: (Not answered)
Correct Answer: D (Target tracking may be lost or erroneous due to sea state, target manoeuvres or shadowing, so it cannot be relied upon entirely)
💡 ARPA tracking is affected by sea state, target manoeuvres, shadowing and input data accuracy, and targets may be lost or plotted in error. The officer must cross-check with the raw radar picture and visual look-out.
✗
Question 68. In addition to the Polar Ship Certificate, a ship operating in polar waters must carry:
Your Answer: (Not answered)
Correct Answer: C (A Polar Water Operational Manual)
💡 SOLAS XIV requires a Polar Water Operational Manual setting out polar procedures and limitations.
✗
Question 69. How should abnormal engine revolutions or speed be judged?
Your Answer: (Not answered)
Correct Answer: B (Taking account of current, wind, draught and hull fouling, with the cause established if abnormal)
💡 Abnormal speed or engine revolutions may result from current, wind, a change of draught, fouling of the hull or propeller or a fault in the engine or shafting. They should be judged against the navigational conditions and the cause established, since a marked loss of speed affects the voyage plan and safety.
✗
Question 70. Who is normally responsible for checking the securing of cargo during the voyage?
Your Answer: (Not answered)
Correct Answer: A (The cargo officer or second officer)
💡 Routine checks of cargo securing are made by those responsible for cargo operations.
✗
Question 71. What is the purpose of the cargo securing manual in a PSC inspection?
Your Answer: (Not answered)
Correct Answer: C (To give the crew the correct securing methods and strength criteria for cargo units)
💡 SOLAS VI/5 and the CSS Code require a cargo securing manual specifying securing methods and strength criteria for cargo units, which the crew use to arrange and check the securing.
✗
Question 72. What is the principle for dealing with a risk of dragging anchor while at anchor?
Your Answer: (Not answered)
Correct Answer: D (Bring engines to readiness immediately, inform the bridge and master, and if necessary weigh or adjust the cable, warning nearby vessels)
💡 On a risk of dragging, engines should be brought to readiness at once, the bridge and master informed, cable veered or the anchor weighed as necessary, and nearby vessels warned, with the position monitored. Waiting or hesitating often leads to grounding or collision.
✗
Question 73. What has to appear on the fire control plan?
Your Answer: (Not answered)
Correct Answer: C (the layout of each deck, the fire divisions and where the detecting and extinguishing gear stands, the whole agreeing with what is there)
💡 The plan is written for the people coming to fight the fire, so it must answer where to get in, what will stop the fire spreading, with what it is to be attacked and how to get out: the decks as arranged and numbered, the boundaries of class A and class B divisions and the fire zones they make, the doors and the dampers, the detection and the alarm, the systems and the appliances with where each stands, the ventilators and the means of closing them, and the ways of escape. It is made of durable material, agrees with the ship as she now is, and is altered when she is altered; a copy stands outside the bridge for the shore brigade and a copy is kept with the company. Hence marking only the extinguishers, the company settling the style, or a general arrangement drawing in place of it all fail - that drawing carries no line of fire division, no detection or extinguishing gear, and is not revised with the work. Each note on the plan is compared with the thing itself, and the commonest finding is the change that was made without the plan being changed.
✗
Question 74. A PSCO tested ventilation closing devices and found some seized. What does SOLAS address?
Your Answer: (Not answered)
Correct Answer: A (Closing devices of machinery space ventilators must close rapidly to cut off ventilation and air supply)
💡 SOLAS II-2 requires machinery space ventilator closing devices to close rapidly and remain effective, cutting off the air supply in a fire. Seized devices or a lack of regular testing are common deficiencies.
✗
Question 75. What is the definition of GMDSS sea area A2?
Your Answer: (Not answered)
Correct Answer: A (An area within MF coast station DSC coverage)
💡 In the GMDSS, sea area A2 is an area within MF coast station continuous digital selective calling coverage, excluding A1. The provision of MF DSC equipment and the corresponding distress alerting means for the trading area is a basic requirement of fitness for that area.
✗
Question 76. What does SOLAS address regarding class A divisions at the galley?
Your Answer: (Not answered)
Correct Answer: A (Class A divisions between the galley and adjacent accommodation, preventing spread of fire and fumes)
💡 SOLAS requires class A divisions between the galley and adjacent accommodation to prevent the spread of fire. Since the galley presents open flame and oil fire risks, inadequate separation would allow fire to reach the accommodation quickly.
✗
Question 77. For a hydraulic steering gear, provision shall be made to detect abnormal conditions by means of:
Your Answer: (Not answered)
Correct Answer: C (a tank level gauge with a low-level alarm)
💡 SOLAS II-1/29 requires a tank level gauge with a low-level alarm to monitor hydraulic fluid leakage.
✗
Question 78. What power supply does SOLAS require for a fixed fire detection system?
Your Answer: (Not answered)
Correct Answer: B (Supplied from both the main and the emergency source, with automatic change-over if the main source fails)
💡 SOLAS requires the fixed fire detection system to be supplied from both the main and the emergency sources with automatic change-over if the main source fails, so that detection continues to work during a blackout.
✗
Question 79. Which code governs the stability and heeling calculations for grain in bulk?
Your Answer: (Not answered)
Correct Answer: C (the grain code, with its stowage manual and the document of authorisation)
💡 Grain in bulk is dealt with on its own terms: the code gives the assumptions for the heeling caused by grain shifting, the stability criteria and what is required of a hold to be filled with grain, the ship carries a grain stowage manual and an authorisation to carry grain in bulk, and the calculation works out the heeling moment of each hold and checks the stability left after the shift. The solid bulk code answers mineral concentrates and coal, cargoes that may liquefy or react; packaged dangerous goods have their own code; the securing manual is about lashing and the forces in it. The mistake made by mixing the three is to treat grain as an ordinary bulk cargo and so leave out the heeling that comes from surface settlement and slope. Levelling and trimming before loading are done as required, and the booklets with the stability figures go to the master for signature.
✗
Question 80. What does SOLAS address regarding fuel for lifeboat engines?
Your Answer: (Not answered)
Correct Answer: B (Fuel with a flashpoint of not less than 43 degrees Celsius, and tank capacity allowing the boat to run at the prescribed speed for a specified time)
💡 SOLAS requires lifeboat engines to use fuel with a flashpoint of not less than 43 degrees Celsius, reducing fire risk, and a tank capacity allowing the boat to run at the prescribed speed for a specified period, ensuring mobility after abandonment.
✗
Question 81. What is the SOLAS requirement regarding independence of means for transmitting distress alerts?
Your Answer: (Not answered)
Correct Answer: B (At least two separate and independent means shall be available)
💡 SOLAS IV/4: at least two separate and independent means shall be available for transmitting distress alerts.
✗
Question 82. What should the owner or master do after deficiencies are recorded in a PSC inspection?
Your Answer: (Not answered)
Correct Answer: A (Take corrective action as required by the port State, keep the evidence and complete it within the prescribed period)
💡 Deficiencies must be rectified within the time required and records kept, with detainable deficiencies cleared before sailing. The handling of deficiencies may affect the ship's risk profile at subsequent inspections.
✗
Question 83. Where must the distress signals of a lifeboat be stowed?
Your Answer: (Not answered)
Correct Answer: A (In a watertight container inside the lifeboat, readily available and protected from damp)
💡 SOLAS requires the distress signals to be stowed in a watertight container in the lifeboat, protected from damp and available at hand if the ship is abandoned. Stowing them on the bridge or in a store would make them unavailable.
✗
Question 84. How must the expiry date of distress signals be managed?
Your Answer: (Not answered)
Correct Answer: D (Check expiry dates periodically and replace expired signals, which may fail or be dangerous)
💡 Distress signals have a definite expiry date and should be checked periodically with expired ones replaced. An expired signal may fail to ignite or behave abnormally, such as premature burning or insufficient height, and failure when genuinely needed endangers life. It is a common deficiency at inspection.
✗
Question 85. In a bridge design review for a new multi-purpose vessel the yard submits four statements: (1) five forward windows with frames kept as narrow as practicable; (2) a refrigeration compressor casing at the conning position blocking about 15 degrees ahead; (3) in ballast the sea surface ahead of the bow is not visible from the conning position; (4) fixed wipers with washing and defrosting on the forward windows. Which statements are non-compliant with SOLAS chapter V?
Your Answer: (Not answered)
Correct Answer: D (items 2 and 3)
💡 The permitted blind sector forward of the conning position is limited, so a 15-degree obstruction ahead is a classic layout error, and the field must be met in both loaded and ballast conditions — a bare claim that the bow can be seen is not enough. Narrow frames, fixed wipers and wash/defrost are what V/22 expects, so 1 and 4 comply.
✗
Question 86. What is the master's obligation regarding charts and nautical publications before sailing?
Your Answer: (Not answered)
Correct Answer: B (They shall be adequate and kept up to date)
💡 SOLAS V/27: charts and nautical publications shall be adequate and kept up to date.
✗
Question 87. What safety is required for lifting appliances at sea?
Your Answer: (Not answered)
Correct Answer: D (Use within the rated load, periodic inspection of wires and brakes and operation by trained persons)
💡 Lifting appliances should be used within the rated safe working load, with periodic inspection of the wires, brakes and limit switches and records kept, operated by trained persons and the slings and cargo securing checked before lifting. Overloading or using defective equipment causes casualties.
✗
Question 88. What action principle do SOLAS and COLREG emphasise once a risk of collision exists?
Your Answer: (Not answered)
Correct Answer: A (Take early and substantial action so as to be readily apparent to the other vessel and avoid a close-quarters situation)
💡 COLREG requires action to be positive, made in ample time and large enough to be readily apparent. Waiting, hesitating or making a succession of small alterations creates confusion and leads to a close-quarters situation.
✗
Question 89. The 15ppm oil content meter alarm is inoperative and the automatic discharge stopping function does not operate. The finding is?
Your Answer: (Not answered)
Correct Answer: C (Loss of monitoring and automatic stop means an over-limit discharge cannot be prevented; a serious deficiency)
💡 The 15ppm oil content meter and the automatic discharge stopping device are key equipment for controlling the discharge of bilge water. The failure of the alarm and of the automatic stop means that an over-limit discharge cannot be automatically prevented and an illegal discharge may result. It is a serious deficiency affecting pollution prevention.
✗
Question 90. What is the primary purpose of ships' routeing under SOLAS V/10?
Your Answer: (Not answered)
Correct Answer: B (To improve safety of navigation and reduce the risk of collision and grounding)
💡 SOLAS V/10 states that the purpose of ships' routeing is to improve safety of navigation and reduce the risk of collision, not to delimit jurisdiction or increase speed.
✗
Question 91. What routine maintenance does the fire main require?
Your Answer: (Not answered)
Correct Answer: A (Periodic checks for corrosion and leakage, freedom of valve operation and prevention of water standing and freezing in the pipe)
💡 The fire main should be checked periodically for corrosion and leakage of the pipe wall and for freedom of valve operation, with standing water prevented from freezing in cold weather and periodic pressure testing, ensuring the system works reliably when needed.
✗
Question 92. In what form shall the fire control plan be presented?
Your Answer: (Not answered)
Correct Answer: D (Plans, with symbols, showing divisions, control stations and fire-fighting appliances on each deck)
💡 Plans with standard symbols showing divisions, control stations and appliances on each deck.
✗
Question 93. Within what time shall the emergency generator start automatically and supply power?
Your Answer: (Not answered)
Correct Answer: A (30 seconds)
💡 Within 30 seconds.
✗
Question 94. In a head-on situation, what is required of the vessels?
Your Answer: (Not answered)
Correct Answer: C (Each alters course to starboard so as to pass on the port side of the other)
💡 Under the collision regulations when two power-driven vessels are meeting on reciprocal or nearly reciprocal courses so as to involve risk of collision, each should alter course to starboard so as to pass on the port side of the other. If in doubt, the situation should be presumed to be head-on and action taken accordingly.
✗
Question 95. On finding a deficiency in the safety management system, what must the master do under the ISM Code?
Your Answer: (Not answered)
Correct Answer: C (Report the deficiency to the shore management and suggest improvements)
💡 ISM Code 5.1.5 requires the master to review the SMS and report deficiencies to the shore-based management with proposals for improvement. He may neither amend the system himself nor merely record the matter in the log.
✗
Question 96. The reserve source of energy for radio installations shall be capable of operating for at least:
Your Answer: (Not answered)
Correct Answer: A (6 hours)
💡 SOLAS IV/13: the reserve source of energy shall be capable of operating the radio installation for at least 6 hours.
✗
Question 97. What is the purpose of the bucket and bailer in a lifeboat?
Your Answer: (Not answered)
Correct Answer: A (Bailing water out of the boat, drawing fresh water and, if necessary, firefighting and washing down)
💡 The bucket and bailer carried in a lifeboat serve several purposes: bailing water out to preserve buoyancy and stability, drawing fresh water and attacking a small fire or washing down. They are practical and important items, and their absence reduces the boat's ability to survive and help itself.
✗
Question 98. What does SOLAS V require when a ship enters a deep-water route?
Your Answer: (Not answered)
Correct Answer: A (To report to the appropriate authority as required and comply with the conditions of use)
💡 SOLAS V requires ships using deep-water routes to report as prescribed and comply with conditions such as under-keel clearance, so as to reduce the risk of grounding.
✗
Question 99. Which type of portable extinguisher is suitable for electrical fires?
Your Answer: (Not answered)
Correct Answer: C (carbon dioxide)
💡 SOLAS II-2/10 requires extinguishers suitable for electrical fires, typically CO2 or dry powder.
✗
Question 100. Where must the equipment of a lifeboat be stowed?
Your Answer: (Not answered)
Correct Answer: C (Inside the boat in designated positions, secured to prevent loss or injury if the boat capsizes)
💡 SOLAS requires the equipment of a lifeboat to be stowed inside the boat in designated positions, such as a locker or secured by lashings, preventing loss or injury if the boat capsizes or during launching. The equipment belongs with the boat and must not be kept on the parent ship.