Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. What is required of an automatic pilot system?
Your Answer: (Not answered)
Correct Answer: D (It shall be possible to change over to manual steering quickly at any time)
💡 Change-over to manual steering shall be possible quickly at any time.
✗
Question 2. What is required regarding the difference between indicated and actual rudder angle?
Your Answer: (Not answered)
Correct Answer: D (The difference must be within the permitted tolerance and corrected if exceeded)
💡 SOLAS and good seamanship require the difference between the indicated and actual rudder angle to be within the permitted tolerance. An excessive difference, such as more than five degrees, misleads the helmsman and the officer, and should be found and corrected at trials.
✗
Question 3. AIS shall be fitted on:
Your Answer: (Not answered)
Correct Answer: C (ships of 300 GT and above on international voyages and cargo ships of 500 GT and above)
💡 SOLAS V/19: AIS shall be fitted on ships of 300 GT and above on international voyages and on cargo ships of 500 GT and above.
✗
Question 4. What does the SOLAS II-2 requirement for the total capacity of fire pumps address?
Your Answer: (Not answered)
Correct Answer: B (The aggregate capacity must meet the prescribed figure and the remaining pumps must still suffice if one is out of action)
💡 SOLAS II-2 specifies the aggregate capacity and requires that, with any one pump out of action, the remaining pumps still deliver the required quantity and pressure, providing redundancy.
✗
Question 5. How is the value of the subdivision index R related to ship type?
Your Answer: (Not answered)
Correct Answer: D (For passenger ships it is determined by length and zone of service, and there are prescribed values for cargo ships)
💡 SOLAS II-1 prescribes values of the subdivision index R by ship type — for passenger ships by length and zone of service, and prescribed values for cargo ships. It is neither uniform nor a matter of choice.
✗
Question 6. What is required regarding the timeliness of system records?
Your Answer: (Not answered)
Correct Answer: A (Records must be completed truthfully and promptly when the event occurs, not written up in a batch later or in advance)
💡 System records, of inspections, maintenance, drills and training, should be completed truthfully and promptly at the time. Writing them up in a batch afterwards or in advance makes them inconsistent with reality, and inconsistencies such as times conflicting with the voyage are readily detected at an inspection and treated as falsification.
✗
Question 7. Emergency lighting batteries are found of insufficient capacity so that the lights cannot last the required time after a power failure. The finding is?
Your Answer: (Not answered)
Correct Answer: A (Emergency lighting cannot last the required duration, a deficiency affecting escape and operational safety)
💡 Emergency lighting, including the emergency source of power, must last the required duration after the main power fails so as to light escape routes, muster stations, engine room escapes and essential operations. Insufficient capacity defeats this function and is a deficiency to be corrected.
✗
Question 8. What does SOLAS address regarding the protection of stairway enclosures?
Your Answer: (Not answered)
Correct Answer: D (Stairways must be enclosed by class A or B divisions, preventing a chimney effect from accelerating fire and smoke spread)
💡 SOLAS requires enclosed stairways in accommodation spaces to be protected by class A or B divisions, preventing the stairwell from acting as a chimney that accelerates the upward spread of flame and smoke, and protecting the escape route.
✗
Question 9. Where a fixed pressure water-spraying system is fitted in a machinery space, its nozzles shall cover:
Your Answer: (Not answered)
Correct Answer: B (all areas of the machinery space where fire may occur)
💡 SOLAS II-2/10 requires the fixed pressure water-spraying system to cover all areas of the machinery space where fire may occur.
✗
Question 10. Before entry into an enclosed space, what preparation must the master ensure?
Your Answer: (Not answered)
Correct Answer: C (Ventilation and testing with calibrated instruments, with satisfactory readings and an entry permit issued)
💡 SOLAS and the IMO resolutions require ventilation, testing of oxygen and toxic and flammable gases with calibrated instruments, and an entry permit issued by the responsible officer before anyone enters.
✗
Question 11. For a cargo ship, the pressure at any hydrant below the maximum breadth shall be not less than:
Your Answer: (Not answered)
Correct Answer: A (0.2 N/mm² (2 bar))
💡 SOLAS II-2/10 requires a pressure of not less than 0.2 N/mm² (2 bar) at any hydrant below the maximum breadth of a cargo ship.
✗
Question 12. How should medical advisory services be used?
Your Answer: (Not answered)
Correct Answer: B (Contact a shore-based medical advisory service by radio or satellite for guidance when a crew member is ill or injured)
💡 SOLAS and the MLC require the ship to contact a shore-based medical advisory service such as a TMAS by radio, satellite or other means for professional guidance when needed, recording the consultation and the treatment given. Prompt advice on an ocean passage markedly improves the outcome.
✗
Question 13. How must matches or an ignition device in a lifeboat be stowed?
Your Answer: (Not answered)
Correct Answer: A (In a watertight container, kept dry and usable)
💡 SOLAS requires the ignition device in a lifeboat to be kept in a watertight container and usable. After abandonment it may be needed for warmth, light or signalling, so damp renders it useless and directly affects survival.
✗
Question 14. A PSC inspection found a lifeboat engine that would not start. What does SOLAS require of lifeboat engines?
Your Answer: (Not answered)
Correct Answer: A (They must start at the prescribed low temperature, with adequate fuel and regular testing including weekly running)
💡 SOLAS requires lifeboat engines to start at the prescribed low temperature, with fuel tanks kept filled, and to be run and tested regularly, including weekly running. No fuel or long neglect of testing are common deficiencies.
✗
Question 15. What watch must be maintained after a distress alert is transmitted?
Your Answer: (Not answered)
Correct Answer: A (A watch on the appropriate distress frequency, ready to answer and establish communication)
💡 After transmitting a distress alert the ship should keep a watch on the appropriate distress and safety frequency, such as VHF channel 16, MF 2182 kHz or the satellite equipment, ready to answer other ships or coast stations, so that distress traffic can be established and assistance obtained as quickly as possible.
✗
Question 16. Which account of the segregation of dangerous goods holds up?
Your Answer: (Not answered)
Correct Answer: A (keeping the goods apart as the IMDG Code requires, from other dangerous goods, from foodstuffs and from accommodation)
💡 Segregation pulls chemically unsuitable substances apart horizontally and vertically to the level the Code gives, so that a leak does not bring them into reaction, foul foodstuffs or reach accommodation; on the stowage plan that becomes the choice of hold and tier, the distance from heat and from living spaces, and the number each term - away from, separated from - calls for. It is not advice and two parties cannot agree it away: the levels already reckon the consequence of a leak, and an agreed change of position may only be made within what the level demands. One hold with two tiers commonly does not satisfy it, some combinations calling for a different hold or separation by a complete deck. The requirement belongs in the plan prepared before loading and is re-worked whenever the stow changes.
✗
Question 17. Before hot work in the cargo tank area of a tanker, what must be done under SOLAS and related guidance?
Your Answer: (Not answered)
Correct Answer: D (Gas testing, a hot work permit, removal of combustibles and firefighting standby precautions)
💡 SOLAS and ISGOTT require gas testing, removal of combustible material, a hot work permit and firefighting standby before hot work in a tanker's cargo area. None of these steps may be omitted.
✗
Question 18. The muster list shall be posted:
Your Answer: (Not answered)
Correct Answer: D (in conspicuous places on board, especially the bridge, machinery spaces and accommodation)
💡 SOLAS III/37 requires the muster list to be posted in conspicuous places, including the bridge, machinery spaces and accommodation.
✗
Question 19. What is required in managing certificates of competence?
Your Answer: (Not answered)
Correct Answer: A (Ensure they are valid and appropriate to the position held and produce them for port State inspection as required)
💡 The certificates of competence, training certificates and medical certificates of the crew should be kept valid and appropriate to the positions held, kept safely on board and produced at inspection. Expired certificates or a mismatch with the position held is a serious deficiency and may lead to the ship being detained or the crew member being required to be replaced.
✗
Question 20. What is required for testing the emergency lighting system?
Your Answer: (Not answered)
Correct Answer: A (Periodic testing of automatic operation and duration, with records kept)
💡 SOLAS and good practice require periodic testing of the automatic operation of the emergency lighting and of its duration, for example by simulating failure of the main source, observing the lighting come on and timing it, verifying the prescribed period with records kept, preventing failure during an actual blackout.
✗
Question 21. On the night watch the OOW must keep track of every watertight door. Under SOLAS chapter II-1, which requirement for power-operated sliding watertight doors is stated correctly?
Your Answer: (Not answered)
Correct Answer: A (the bridge shall carry indicators showing each door open or closed, closing normally taking between 20 and 40 seconds with the alarm sounding throughout)
💡 Bridge indicators showing each door individually exist so the OOW can confirm watertight integrity at any moment, not only after flooding; the 20-40 second closing time and continuous alarm give persons below the door time to clear. Verbal relaying or control-room-only indication is a substitute the regulation does not accept.
✗
Question 22. Before the ship proceeds to sea, the voyage plan shall be prepared by:
Your Answer: (Not answered)
Correct Answer: B (the master)
💡 SOLAS V/34: the voyage plan shall be prepared before departure by the master.
✗
Question 23. Besides rocket parachute flares and hand flares, which other pyrotechnic is required among the lifeboat's distress signals?
Your Answer: (Not answered)
Correct Answer: A (Buoyant smoke signals)
💡 SOLAS III/7.2 requires the lifeboat to carry distress signals comprising rocket parachute flares, hand flares and buoyant smoke signals. Extinguishers and first aid kits are separate items of equipment.
✗
Question 24. If a PSC deficiency involves the responsibility of a classification society, what does the port State do?
Your Answer: (Not answered)
Correct Answer: B (Notify the flag State and the recognised organisation, requiring follow-up and confirmation of rectification)
💡 Where a deficiency involves the responsibility of a classification society as a recognised organisation, the port State notifies the flag State and the organisation, requiring assessment and follow-up, such as an additional survey or rectification. This is the statutory notification mechanism between port State, flag State and recognised organisation.
✗
Question 25. After a marine casualty such as a collision or grounding with serious loss, what is required of the master as to reporting?
Your Answer: (Not answered)
Correct Answer: C (Report to the flag Administration as required and, where necessary, to the nearest coastal State, and preserve the relevant records and information)
💡 Under SOLAS I/21 and related requirements, after a marine casualty the ship should report to the flag Administration as required and, where necessary, to the nearest coastal State, and should preserve evidence, the official log book and related records for the investigation. Concealing or delaying a report aggravates liability.
✗
Question 26. What is the purpose of the voyage data recorder required by SOLAS V/19?
Your Answer: (Not answered)
Correct Answer: C (To provide data on the navigation and operation of the ship for accident investigation)
💡 The VDR records navigational and operational data for use in casualty investigation. The data is protected and must not be used for crew assessment or other purposes.
✗
Question 27. For how long shall the emergency source of power on a passenger ship be capable of supplying the emergency services?
Your Answer: (Not answered)
Correct Answer: B (36 hours)
💡 SOLAS II-1/42: 36 hours on passenger ships; 18 hours on cargo ships.
✗
Question 28. What monitoring of the steering gear is required in normal operation?
Your Answer: (Not answered)
Correct Answer: C (Monitor noise, temperature, oil level and response, investigating any abnormality promptly)
💡 In service the steering gear should be monitored by abnormal noise, changes in oil temperature or level, slow response or increased steering effort, with any abnormality investigated promptly, such as leakage in the hydraulic system, deterioration of the oil or mechanical seizure, preventing loss of steering at sea.
✗
Question 29. What shall be provided between the bridge and the steering gear compartment?
Your Answer: (Not answered)
Correct Answer: D (Reliable communication such as a sound-powered telephone)
💡 Reliable communication, such as a sound-powered telephone, shall be provided.
✗
Question 30. What fire rating does SOLAS normally require for the boundary between a category A machinery space and accommodation spaces?
Your Answer: (Not answered)
Correct Answer: D (A-60 class division)
💡 SOLAS normally requires A-60 class boundaries between category A machinery spaces and accommodation and service spaces because of the high fire risk in machinery spaces.
✗
Question 31. What is the principal means by which a flag State discharges its supervision?
Your Answer: (Not answered)
Correct Answer: A (Issuing valid certificates and carrying out surveys)
💡 Certification and survey are the principal means of flag State supervision.
✗
Question 32. What is required regarding the stability information at a renewal survey?
Your Answer: (Not answered)
Correct Answer: D (Verify that it agrees with the actual condition of the ship and update it if the loading conditions have changed)
💡 SOLAS requires the approved stability information to be verified at survey as agreeing with the actual condition of the ship, structure, equipment and loading conditions. Where the ship is converted, the loading method changes or the weight distribution alters, the information should be updated and approved.
✗
Question 33. What is the minimum rest requirement for a crew member in any 24-hour period?
Your Answer: (Not answered)
Correct Answer: A (At least ten hours)
💡 Under STCW and the related requirements of the Maritime Labour Convention 2006, a crew member must have at least ten hours of rest in any twenty-four hour period, which may be divided into not more than two periods one of which is at least six hours, with at least seventy-seven hours of rest in any seven-day period.
✗
Question 34. Which Code governs the stability of ships carrying grain in bulk?
Your Answer: (Not answered)
Correct Answer: C (The International Grain Code)
💡 The International Grain Code.
✗
Question 35. What does SOLAS III/19 require regarding lifeboats in abandon ship drills?
Your Answer: (Not answered)
Correct Answer: A (At least once every three months the boat is to be launched, and where reasonable and practicable lowered to the water and manoeuvred)
💡 SOLAS III/19 requires launching drills at least every three months, with the boat, where reasonable and practicable, lowered into the water and manoeuvred at least once in that period.
✗
Question 36. What is required for the use of safety harnesses during cargo securing?
Your Answer: (Not answered)
Correct Answer: B (A harness secured to a reliable point is required when working on top of containers or at height)
💡 Securing work on top of containers, on hatch coamings or at height requires a safety harness secured to a reliable point, with attention to ship movement, wind and sea and to the effect on adjacent work, preventing falls from height.
✗
Question 37. On what basis must first aid be given in a dangerous goods incident involving poisoning or burns?
Your Answer: (Not answered)
Correct Answer: D (MFAG, the Medical First Aid Guide for use in accidents involving dangerous goods)
💡 SOLAS VII requires MFAG to be carried on board, with first aid given according to the relevant card, such as decontamination, oxygen and artificial respiration, gaining time for subsequent medical treatment.
✗
Question 38. When loading solid bulk cargoes liable to liquefy, care must be taken to prevent:
Your Answer: (Not answered)
Correct Answer: B (Water accumulation in the holds)
💡 Accumulated water can cause liquefaction, so trimming and drainage are essential.
✗
Question 39. A class divisions on a passenger ship shall be capable of preventing the passage of smoke and flame to the end of a 60-minute standard fire test. The fire integrity is:
Your Answer: (Not answered)
Correct Answer: B (determined by structure, generally not less than 60 minutes)
💡 A class divisions are defined to withstand a standard fire test for 60 minutes without passage of smoke and flame.
✗
Question 40. What are the usual transmit power settings of a ship's VHF radiotelephone?
Your Answer: (Not answered)
Correct Answer: A (1 watt (low) and 25 watts (high))
💡 A ship's VHF normally has two settings, one watt for low power and twenty-five watts for high power, low power being used for short-range communication to reduce interference and high power for long range or distress communication to ensure coverage. Selecting the right setting is a basic watchkeeping requirement.
✗
Question 41. On what principle are portable extinguishers provided in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: A (According to the arrangement of the spaces, so that an extinguisher can be reached quickly wherever a fire starts)
💡 SOLAS requires portable extinguishers distributed according to the arrangement of accommodation spaces, so that one can be reached quickly wherever a fire starts. Central stowage prevents timely attack on a fire in its early stage.
✗
Question 42. What rescue preparation is required for enclosed space entry?
Your Answer: (Not answered)
Correct Answer: A (Rescue equipment including breathing apparatus and a lifting harness must be ready with personnel standing by, not sought at the time)
💡 Before entering an enclosed space, rescue equipment such as self-contained breathing apparatus, a harness and lifting line and a stretcher must be ready with personnel standing by, so that rescue can begin at once if something goes wrong. Seeking equipment at the time is a principal cause of multiple fatalities.
✗
Question 43. Regarding the master's duties, which is correct?
Your Answer: (Not answered)
Correct Answer: D (the master has ultimate responsibility for safe navigation and shall take charge when necessary)
💡 SOLAS V/34: the master has ultimate responsibility for safe navigation and shall take charge when necessary.
✗
Question 44. What does SOLAS address regarding the axe in a firefighter's outfit?
Your Answer: (Not answered)
Correct Answer: D (An axe suitable for breaking through must be provided and stowed with the rest of the outfit)
💡 SOLAS requires an axe to be provided in the firefighter's outfit for breaking through doors, windows and structure in smoke-filled or obstructed conditions, stowed with the rest of the outfit in an accessible position.
✗
Question 45. What is the requirement for the safety lamp in a firefighter's outfit?
Your Answer: (Not answered)
Correct Answer: D (An electric safety lamp capable of continuous illumination for at least three hours)
💡 SOLAS requires an electric safety lamp giving continuous illumination for at least three hours, safe in smoke and flammable atmospheres. Ordinary torches and flame lamps are not acceptable.
✗
Question 46. What do SOLAS and good practice address regarding inspection and maintenance of extinguishers?
Your Answer: (Not answered)
Correct Answer: A (Periodic checks of weight or pressure with records kept)
💡 SOLAS requires portable extinguishers to be checked periodically for pressure or weight, seal and discharge mechanism, with records kept, preventing leakage or failure of the agent so that the extinguisher cannot put out a fire when needed.
✗
Question 47. What fire precautions apply before entering a cargo tank or other enclosed space on a tanker?
Your Answer: (Not answered)
Correct Answer: C (Thorough ventilation and gas testing to confirm no flammable gas and acceptable oxygen content, with ventilation maintained during entry)
💡 Before entering a cargo tank, pump room or similar enclosed space on a tanker, thorough ventilation is required with testing of flammable gas, toxic gas and oxygen content all satisfactory, and an entry permit obtained, ventilation maintained during the entry and explosion-protected lighting and tools used, preventing ignition.
✗
Question 48. What does SOLAS address regarding stability when carrying timber deck cargo?
Your Answer: (Not answered)
Correct Answer: B (The increase in weight from water absorbed by the timber and ice accretion must be included, with the prescribed stability criteria applied)
💡 SOLAS and the Load Line Convention prescribe stability requirements for ships carrying timber deck cargo, requiring account to be taken of the weight gained from water absorbed, ice accretion and increased windage, assessed against the prescribed criteria, failing which capsize may occur.
✗
Question 49. In radiocommunication, what is the priority of distress communication?
Your Answer: (Not answered)
Correct Answer: B (It has the highest priority above all other communication, which must give way to it)
💡 Under the Radio Regulations and the GMDSS distress communication has the highest priority and all other communication must give way and keep silence while it is in progress. A ship receiving a distress alert or distress traffic must not use the distress frequencies for non-distress communication.
✗
Question 50. Which is the 4 MHz band DSC distress frequency among the HF frequencies?
Your Answer: (Not answered)
Correct Answer: A (4207.5 kHz)
💡 HF DSC distress frequencies are 4207.5, 6312, 8414.5, 12577 and 16804.5 kHz. 2187.5 kHz is an MF frequency and 6312 kHz belongs to the 6 MHz band.
✗
Question 51. Which statement about the remote starting of fire pumps is correct?
Your Answer: (Not answered)
Correct Answer: C (Fire pumps should be capable of being started remotely from the bridge or fire control station, or readily started locally, for prompt water supply)
💡 Under SOLAS II-2/10 fire pumps should be capable of being started from the bridge or fire control station, or otherwise ensured to start promptly and supply the fire main in a fire. The means of starting should be stated in the operating instructions, with which the crew should be familiar. The emergency fire pump should have an independent source of power and self-priming capability.
✗
Question 52. What is the minimum number of fire pumps for a cargo ship of 1000 gross tonnage and above?
Your Answer: (Not answered)
Correct Answer: C (At least two independently driven fire pumps)
💡 Under SOLAS II-2/10 a cargo ship of 1000 gross tonnage and above should have at least two independently driven fire pumps so that water is still supplied if one fails. Each pump's capacity is not less than eighty per cent of the total required and the main pressure must be met.
✗
Question 53. A cargo ship is 140 m in length with a crew of 20. What capacity must the survival craft on each side provide under SOLAS III/31?
Your Answer: (Not answered)
Correct Answer: D (Each side must accommodate all 20 persons on board)
💡 SOLAS III/31 requires the survival craft on each side of a cargo ship to accommodate all persons on board, so that everyone can escape whichever side is unusable. Counting the total for both sides only is not sufficient.
✗
Question 54. What does SOLAS address regarding fire protection of the cargo pump room on a tanker?
Your Answer: (Not answered)
Correct Answer: D (Class A divisions at its boundaries with a fixed extinguishing system and fire detection inside)
💡 SOLAS requires the boundaries of a cargo pump room on a tanker to be class A divisions, with a fixed extinguishing system, normally CO2 or foam, and fire detection inside, since the pump room is a high risk space for accumulation and explosion of vapour.
✗
Question 55. What should be done about a failed water ingress detector on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (Repair promptly and, pending repair, increase manual checks such as sounding the bilges, with records kept)
💡 A failed water ingress detector should be repaired as soon as possible and, pending repair, manual checks increased, such as periodic sounding of holds, ballast tanks and bilges, with the failure and the temporary measures recorded. Switching the system off would remove the warning of flooding and is a serious deficiency.
✗
Question 56. The pumping system requirement for bulk carriers applies to:
Your Answer: (Not answered)
Correct Answer: C (new bulk carriers, which shall be able to drain cargo holds under specified conditions)
💡 SOLAS XII/13: new bulk carriers shall be provided with a pumping system able to drain cargo holds under specified conditions.
✗
Question 57. Which means of look-out meets SOLAS requirements?
Your Answer: (Not answered)
Correct Answer: A (Sight, hearing and all available means appropriate to the circumstances)
💡 Sight, hearing and all available means appropriate to the circumstances.
✗
Question 58. What is the sequence of action when visibility suddenly deteriorates at sea?
Your Answer: (Not answered)
Correct Answer: A (Inform the master at once, prepare the engine and reduce to a safe speed, start radar and navigation lights, sound fog signals and enhance the look-out)
💡 Sudden loss of visibility requires prompt action in sequence: inform the master, tell the engine room to stand by and reduce to a safe speed, start the radar on a longer range scale and switch on navigation lights, sound fog signals as prescribed, post an additional look-out and keep a sharp listening watch, considering anchoring if necessary.
✗
Question 59. What is the minimum number of two-way VHF radiotelephone sets for a cargo ship?
Your Answer: (Not answered)
Correct Answer: A (Three, with at least one on each side)
💡 Under SOLAS IV/7 a cargo ship should carry at least three two-way VHF radiotelephone sets, with at least one on each side and the remainder stowed such as on the bridge, so that they can be taken into the respective survival craft for on-scene communication during abandonment.
✗
Question 60. What fire detection is required in spaces carrying dangerous goods?
Your Answer: (Not answered)
Correct Answer: C (Detection suited to the cargo, with gas detection for certain cargoes)
💡 SOLAS and the IMDG Code require spaces carrying dangerous goods to have detection suited to the cargo, such as smoke, heat or gas detection, with gas detection and alarm where flammable gas may be released, so that an incipient fire or a leak is detected promptly.
✗
Question 61. Who must confirm the securing arrangement for cargo units under SOLAS and the CSS Code?
Your Answer: (Not answered)
Correct Answer: A (The master or chief officer, in accordance with the approved cargo securing manual)
💡 SOLAS VI/5 and the CSS Code require the securing arrangement to be determined in accordance with the approved cargo securing manual and confirmed by the master or the responsible officer as to position, number and pre-tension. It is not left to the terminal or the cargo owner.
✗
Question 62. What first aid is required for an injury at sea?
Your Answer: (Not answered)
Correct Answer: C (Give first aid at once, inform the bridge and request medical advice as necessary, recording the injury and treatment)
💡 An injury requires immediate first aid, the bridge and master being informed and medical advice requested where necessary, including a MEDEVAC, with the injury, time and treatment recorded. Delay worsens the outcome, particularly on an ocean passage.
✗
Question 63. What is the requirement for the total capacity of fire pumps?
Your Answer: (Not answered)
Correct Answer: A (It shall be sufficient to supply the required jets at the minimum pressure)
💡 Pumps shall supply the required jets at the prescribed minimum pressure.
✗
Question 64. How often shall the Company carry out internal audits of the SMS?
Your Answer: (Not answered)
Correct Answer: A (At least once a year)
💡 At least once a year.
✗
Question 65. Insulation was removed from a fire division for work and not replaced. What is the finding?
Your Answer: (Not answered)
Correct Answer: B (A deficiency; missing insulation reduces the fire performance of the division and must be restored promptly)
💡 Insulation removed from a fire division, for example to gain access during work, and not replaced significantly reduces its fire performance, so heat and fire cannot be effectively contained. It is a deficiency affecting safety and must be restored promptly with approved material.
✗
Question 66. Ships shall be provided with heading indication by means of:
Your Answer: (Not answered)
Correct Answer: D (a gyro-compass or magnetic compass providing heading indication on the bridge)
💡 SOLAS V/19 requires heading indication equipment providing heading to the bridge.
✗
Question 67. What do SOLAS V and COLREG require when navigating in a narrow channel?
Your Answer: (Not answered)
Correct Answer: A (Keep as near to the outer limit on the starboard side as is safe and practicable, at a safe speed with an adequate look-out)
💡 COLREG Rule 9 requires a vessel in a narrow channel to keep as near to the outer limit on her starboard side as is safe and practicable, at a safe speed with an adequate look-out. High speed or occupying any part of the channel greatly increases the risk of collision.
✗
Question 68. An inert gas system shall keep the oxygen content of cargo tank atmospheres below:
Your Answer: (Not answered)
Correct Answer: B (8%)
💡 SOLAS II-2/5 requires the inert gas system to maintain the oxygen content of cargo tank atmospheres below 8% by volume.
✗
Question 69. What does the ISM Code address regarding the link between drills and incident reporting?
Your Answer: (Not answered)
Correct Answer: D (Problems revealed in drills should be analysed and used for improvement, together with accident and near-miss reporting)
💡 ISM Code 9 requires non-conformities, accidents and hazardous occurrences to be investigated and analysed with corrective action. Problems revealed in drills should likewise be analysed and used for improvement, serving as a basis for raising the standard of safety management.
✗
Question 70. In addition to one per person, passenger ships shall carry:
Your Answer: (Not answered)
Correct Answer: A (an additional appropriate number of lifejackets for watchkeeping and other personnel)
💡 SOLAS III/7 requires passenger ships to carry additional lifejackets for watchkeeping personnel and those at muster stations.
✗
Question 71. A cargo ship of 85 m in length is equipping lifebuoys. Under SOLAS III/7.1, what is the minimum number required?
Your Answer: (Not answered)
Correct Answer: A (12)
💡 SOLAS III/7.1 sets bands by length: under 60 m — 8; 60 m and under 120 m — 12; 120 m and under 180 m — 18; 180 m and above — 24. At 85 m the second band applies.
✗
Question 72. For a ship without an approved treatment plant, what is the general distance requirement for the discharge of sewage?
Your Answer: (Not answered)
Correct Answer: C (Beyond 12 nautical miles from the nearest land and at the specified speed)
💡 Under MARPOL Annex IV, where no approved treatment plant is fitted, sewage may generally be discharged beyond twelve nautical miles from the nearest land and subject to speed and other conditions, while a ship with an approved plant may discharge closer when the conditions are met. Port States may also have stricter local rules.
✗
Question 73. Ventilation inlets of machinery spaces of tankers should be located at which position to effectively remove hydrocarbon vapours?
Your Answer: (Not answered)
Correct Answer: A (top of the space)
💡 SOLAS II-2/4 requires ventilating inlets at the top of the space to remove accumulated hydrocarbon or flammable vapours.
✗
Question 74. What does SOLAS require for the power or drive of the emergency fire pump?
Your Answer: (Not answered)
Correct Answer: D (It must be independently driven with a power or fuel supply unaffected by a fire in the machinery space)
💡 SOLAS requires the emergency fire pump to be independently driven, with its source of power or fuel arranged so that a fire in the machinery space does not put it out of action.
✗
Question 75. A shipment of dangerous goods is offered without a proper shipping name. What should the master do?
Your Answer: (Not answered)
Correct Answer: D (Require the proper shipping name, UN number and other information, refusing to load if it is incomplete)
💡 SOLAS VII and the IMDG Code require dangerous goods to be declared under the proper shipping name with the UN number, class and packing group. An incomplete declaration or a general description such as chemicals would leave the crew unable to identify the hazards. The master should require full information, or refuse to load.
✗
Question 76. An embarkation ladder is found with missing treads and corroded ropes. The finding is?
Your Answer: (Not answered)
Correct Answer: C (The embarkation ladder is vital for safe boarding during abandonment; damage is a serious life-saving deficiency)
💡 The embarkation ladder is the means by which personnel board the survival craft from the deck during abandonment and its treads, side ropes and securing arrangements should be intact. Damage may cause a person to fall and be injured during emergency boarding, directly endangering safety. It is a serious life-saving deficiency to be corrected.
✗
Question 77. Into how many classes does the IMDG Code divide packaged dangerous goods?
Your Answer: (Not answered)
Correct Answer: D (Nine)
💡 The IMDG Code divides packaged dangerous goods into nine classes by hazard type, for example Class 1 explosives, Class 2 gases and Class 3 flammable liquids. The number is fixed at nine.
✗
Question 78. A ship's radio reserve source is a battery. For how long must its capacity sustain operation under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (At least one hour of communication, including distress alerting capability)
💡 SOLAS IV/9 requires the reserve source to sustain at least one hour of essential communication including distress alerting after the main source fails. Where the emergency source also supplies the radio installation, it may be taken into account.
✗
Question 79. How is continual improvement of the safety management system demonstrated?
Your Answer: (Not answered)
Correct Answer: A (Through a cycle of setting objectives, monitoring performance, identifying problems at audit and taking improvement action)
💡 Continual improvement is achieved through a cycle of setting safety and pollution prevention objectives, monitoring performance such as accident rates, non-conformities and deficiency numbers, identifying problems through audit and review and taking corrective and preventive action, so that the system is continuously refined rather than being fixed once established.
✗
Question 80. For side scuttles in the shell below the freeboard deck, what is required as to type and closing appliances?
Your Answer: (Not answered)
Correct Answer: D (A type complying with the requirements according to position and the limiting line, with effective closing appliances to prevent the entry of water)
💡 Under SOLAS II-1/26 and similar requirements, side scuttles in the shell below the freeboard deck should be of an appropriate type, such as a fixed light with a hinged deadlight, and have effective closing appliances, such as inside deadlights, ensuring that water does not enter the hull in flooding or boarding seas. Openings below the limiting line are more strictly restricted.
✗
Question 81. How many torches shall a lifeboat carry among its equipment?
Your Answer: (Not answered)
Correct Answer: B (Two)
💡 At least two torches.
✗
Question 82. What interval does SOLAS III/20 require for routine inspection of life-saving appliances?
Your Answer: (Not answered)
Correct Answer: C (At least once a week)
💡 SOLAS III/20 requires life-saving appliances to be inspected at least weekly so as to remain ready for use. Monthly inspections are the more detailed visual checks of survival craft and launching appliances.
✗
Question 83. What does SOLAS require for quick closing valves in the fuel oil system of a machinery space?
Your Answer: (Not answered)
Correct Answer: A (Quick closing valves at fuel tank outlets and at fuel pumps, remotely operable from outside the space)
💡 SOLAS requires quick closing valves at fuel tank outlets and at fuel pumps, capable of remote operation from a readily accessible position, normally outside the space, so the fuel supply can be cut off rapidly in a machinery space fire.
✗
Question 84. What is the essential capability of the windlass while at anchor?
Your Answer: (Not answered)
Correct Answer: D (Reliably braking the anchor so that it will not drag)
💡 SOLAS II-1/31: the windlass must be capable of holding the anchor reliably in bad weather.
✗
Question 85. Each person in a lifeboat shall be provided with fresh water of not less than:
Your Answer: (Not answered)
Correct Answer: A (3 litres)
💡 SOLAS III/34 requires not less than 3 litres of fresh water per person in a lifeboat.
✗
Question 86. What is the particular danger of a cargo leak on a gas carrier?
Your Answer: (Not answered)
Correct Answer: A (The cargo is often cryogenic, flammable or toxic; a leak vaporises rapidly and may form a flammable or toxic cloud)
💡 Gas carrier cargoes such as LPG and LNG are cryogenic, flammable, explosive or toxic. A leak vaporises rapidly and mixes with air to form a flammable or toxic cloud which may flash or explode on contact with a source of ignition, so the response must be by trained personnel.
✗
Question 87. Fuel oil used in machinery spaces shall generally have a flash point (closed cup) of not less than:
Your Answer: (Not answered)
Correct Answer: A (60 °C)
💡 SOLAS II-2/4 generally requires a flash point of not less than 60 °C, except emergency generators may use fuel with a flash point of not less than 43 °C.
✗
Question 88. Each ship shall carry how many lifejackets for every person on board?
Your Answer: (Not answered)
Correct Answer: D (one per person)
💡 SOLAS III/7 requires one lifejacket for every person on board, with additional child lifejackets as required.
✗
Question 89. What does SOLAS provide regarding combining different types of drill?
Your Answer: (Not answered)
Correct Answer: B (Drills of different kinds may be combined where reasonable and practicable, provided the objectives of each are met)
💡 SOLAS permits drills of different kinds, such as abandon ship and fire drills, to be combined where reasonable and practicable, provided that the training objectives of each are achieved. Combining must not mean omitting essential elements.
✗
Question 90. What does SOLAS address regarding stowage and immediate availability of survival craft?
Your Answer: (Not answered)
Correct Answer: C (Stowed where they can be reached and launched promptly, in a condition of immediate readiness)
💡 SOLAS requires survival craft to be stowed where they can be reached and launched promptly and to be in a condition of immediate readiness, with gravity davits able to be released without preparation. Dismantling them or stowing them in a hold makes them unusable on abandonment.
✗
Question 91. During a PSC inspection the firefighter's outfits were checked. Under SOLAS II-2/10.1, which of the following is NOT part of a firefighter's outfit?
Your Answer: (Not answered)
Correct Answer: D (A portable gas detector)
💡 SOLAS II-2/10.1 defines a firefighter's outfit as personal equipment (protective clothing, boots and gloves, rigid helmet, electric safety lamp and axe) together with a self-contained compressed air breathing apparatus. A gas detector belongs to other requirements such as enclosed space entry and is not part of the outfit.
✗
Question 92. Rescue boat recovery appliances shall be capable of recovering the rescue boat with persons and equipment at ship's headway of up to:
Your Answer: (Not answered)
Correct Answer: B (5 knots)
💡 SOLAS III/16 requires recovery at ship's headway of up to 5 knots.
✗
Question 93. What is examined in testing a fixed fire detection and alarm system?
Your Answer: (Not answered)
Correct Answer: B (The alarm function of detectors tested point by point or by section, and that the display corresponds to the actual location)
💡 Testing a fixed detection and alarm system involves triggering detectors point by point or by section and confirming that the alarm sounds correctly and accurately indicates the space concerned, so that the watchkeeper can locate it quickly. Powering it on or listening for the sound alone does not confirm correct sectional indication.
✗
Question 94. What does SOLAS III/36 require for maintenance of survival craft and launching appliances?
Your Answer: (Not answered)
Correct Answer: C (A planned maintenance system on board in accordance with the manufacturer's instructions)
💡 SOLAS III/36 requires planned maintenance of survival craft and launching appliances on board in accordance with the manufacturer's instructions, with records kept. Breakdown maintenance alone is not acceptable.
✗
Question 95. What is the period of validity of the International Ship Security Certificate?
Your Answer: (Not answered)
Correct Answer: C (Not more than five years)
💡 SOLAS XI-2 provides that the ISSC is valid for not more than five years, with intermediate verification arranged separately. It is not valid indefinitely.
✗
Question 96. Which Code governs the construction of ships carrying liquefied gases in bulk?
Your Answer: (Not answered)
Correct Answer: B (The IGC Code)
💡 The IGC Code.
✗
Question 97. Which measure complies with SOLAS for protection against electric shock?
Your Answer: (Not answered)
Correct Answer: C (Live parts shall be protected against accidental contact)
💡 Live parts which may be accidentally touched shall be protected.
✗
Question 98. What is the principal characteristic of class 2 dangerous goods under the IMDG Code?
Your Answer: (Not answered)
Correct Answer: B (Gases, including compressed, liquefied and dissolved gases, presenting flammable, toxic or asphyxiant hazards)
💡 Class 2 of the IMDG Code covers gases, compressed, liquefied or dissolved under pressure, divided into flammable, non-flammable non-toxic and toxic gases. Flammable liquids are class 3 and radioactive material class 7.
✗
Question 99. From what tonnage shall the main steering gear have two independent power units?
Your Answer: (Not answered)
Correct Answer: D (10000 GT)
💡 From 10000 GT and above.
✗
Question 100. The emergency steering position shall be located:
Your Answer: (Not answered)
Correct Answer: B (in the steering gear compartment)