Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. What communication is required for key shipboard operations?
Your Answer: (Not answered)
Correct Answer: D (Operations involving several parties must have a designated person in charge, maintained communication and confirmation of key steps)
💡 The ISM Code requires key operations involving several persons or departments, such as cargo work, ballasting, bunkering and hot work, to have a designated person in charge, a communication arrangement including a briefing before starting and confirmation of the key steps, preventing accidents or pollution from a failure of communication.
✗
Question 2. What is required of the master during a PSC inspection?
Your Answer: (Not answered)
Correct Answer: B (Provide information truthfully and arrange for personnel to assist, without concealing deficiencies or obstructing the inspection)
💡 Port State control is a legal power. The master should provide certificates, records and information truthfully, arrange for the crew to assist and explain the situation truthfully. Concealing, falsifying or obstructing leads to escalation and even coercive measures and a higher risk profile for the ship.
✗
Question 3. Which means of look-out meets SOLAS requirements?
Your Answer: (Not answered)
Correct Answer: A (Sight, hearing and all available means appropriate to the circumstances)
💡 Sight, hearing and all available means appropriate to the circumstances.
✗
Question 4. Which symbol denotes the degree of subdivision of a passenger ship?
Your Answer: (Not answered)
Correct Answer: D (R)
💡 A required subdivision index is applied to passenger ships.
✗
Question 5. What is the purpose of sailing directions among the nautical publications required on board?
Your Answer: (Not answered)
Correct Answer: C (To provide written information on navigational conditions, dangers and coastal features of the area)
💡 Sailing directions give written information on navigational conditions, dangers, ports and coastal features, complementing the charts, and are among the publications required by SOLAS.
✗
Question 6. The gas regulating valve in a tanker inert gas system is used to:
Your Answer: (Not answered)
Correct Answer: C (regulate the flow of inert gas into cargo tanks and prevent backflow)
💡 SOLAS II-2/5 requires a gas regulating valve to control inert gas flow into cargo tanks and prevent backflow.
✗
Question 7. What is the principal risk addressed by the requirements for venting arrangements of tanker cargo tanks?
Your Answer: (Not answered)
Correct Answer: B (Preventing overpressure or vacuum in the tanks caused by cargo operations and temperature changes)
💡 Venting arrangements equalise tank pressure during cargo operations and temperature changes, preventing structural damage from overpressure and deformation from vacuum.
✗
Question 8. The reserve source of energy for radio installations shall be capable of operating for at least:
Your Answer: (Not answered)
Correct Answer: A (6 hours)
💡 SOLAS IV/13: the reserve source of energy shall be capable of operating the radio installation for at least 6 hours.
✗
Question 9. The ship security alert system (SSAS) fails its test and cannot transmit an alert to the Administration. The finding is?
Your Answer: (Not answered)
Correct Answer: B (SSAS failure affects the ability to call for help when attacked, a security equipment deficiency to be corrected)
💡 The ship security alert system should be able to transmit an alert to the shore receiving point designated by the Administration when the ship is under a security threat and should be available at all times. A failed test shows it cannot fulfil its function at the critical moment. It is a security equipment deficiency to be corrected.
✗
Question 10. What does SOLAS require regarding the arrangement of scuppers, inlets and discharges on a ship's sides?
Your Answer: (Not answered)
Correct Answer: C (They must not lead water into spaces where it would be dangerous, and reliable means of closure must be fitted)
💡 SOLAS II-1 regulates the arrangement and closing appliances of overboard scuppers and inlets so that water cannot enter spaces where it would create a hazard through damage or inadvertent operation.
✗
Question 11. What is the required sequence in a simulated fire alarm during a fire drill?
Your Answer: (Not answered)
Correct Answer: A (Discovering the fire, raising the alarm, mustering, establishing the situation and firefighting, with responsibilities at each stage clear)
💡 A fire drill should follow the full sequence: raising the alarm on discovering the fire, including use of manual call points, mustering under the muster list, establishing the location and nature of the fire, firefighting and search under the master's or the on-scene commander's orders and releasing the fixed system if necessary, so that the stages connect smoothly.
✗
Question 12. What time requirement does SOLAS address for the stowage of and embarkation into survival craft?
Your Answer: (Not answered)
Correct Answer: D (All persons must be able to embark and the craft launched within the prescribed time)
💡 SOLAS requires stowage and embarkation arrangements enabling all persons to board and the craft to be launched within the prescribed time, based on the rate at which the ship might sink. Excessive time means not everyone could get away.
✗
Question 13. Besides the emergency duties of each crew member, what else must the muster list specify?
Your Answer: (Not answered)
Correct Answer: B (The muster stations)
💡 SOLAS III/37: the muster list shall specify duties and muster stations.
✗
Question 14. Where shall the launching appliance for survival craft be located?
Your Answer: (Not answered)
Correct Answer: B (So that launching on either side is safe)
💡 So that launching is safe on the side where the craft is stowed.
✗
Question 15. Means of escape from machinery spaces shall be:
Your Answer: (Not answered)
Correct Answer: A (clearly marked to indicate the escape direction, with emergency lighting where necessary)
💡 SOLAS II-2/13 requires means of escape to be clearly marked and provided with emergency lighting.
✗
Question 16. From what source must radio equipment be supplied when the main source of power fails?
Your Answer: (Not answered)
Correct Answer: D (From the emergency source or a dedicated reserve source, maintaining distress communication capability)
💡 SOLAS IV/9 requires radio equipment to be supplied from the emergency source or a dedicated reserve source for at least one hour, so that distress alerting capability is not lost.
✗
Question 17. The deck foam system of a tanker shall be capable of supplying foam over the protected deck area within:
Your Answer: (Not answered)
Correct Answer: A (30 minutes)
💡 SOLAS II-2/20: the deck foam system shall be capable of supplying foam over the protected deck area within 30 minutes.
✗
Question 18. What periodic testing does the bilge system require?
Your Answer: (Not answered)
Correct Answer: D (Periodic water tests confirming that each compartment suction drains effectively, with strainers and valves checked)
💡 SOLAS and good practice require periodic water tests of the bilge system, confirming that the suction in each compartment drains effectively, that strainers are clear and valves operate reliably, with the results recorded, preventing the system from failing when needed.
✗
Question 19. Within what time shall the emergency generator start and supply power automatically on loss of the main supply?
Your Answer: (Not answered)
Correct Answer: D (30 seconds)
💡 SOLAS II-1/44: the emergency generator shall start automatically within 30 seconds.
✗
Question 20. What does SOLAS address regarding the arrangement of ventilation inlets and outlets in machinery spaces?
Your Answer: (Not answered)
Correct Answer: D (They must be arranged to avoid short circuiting and ensure effective air change)
💡 SOLAS requires the inlets and outlets of machinery space ventilation to be arranged to avoid short circuiting and ensure effective air change, preventing excessive temperature or accumulation of flammable gas, both of which affect equipment and safety.
✗
Question 21. What is required regarding the use of torches and signal lights at night?
Your Answer: (Not answered)
Correct Answer: C (Bright lights that could be mistaken for navigation lights or mislead others must be avoided, so as not to affect others' appreciation or one's own look-out)
💡 COLREG and good seamanship require avoiding lights at night that could be mistaken for navigation lights or mislead another vessel. A searchlight must be used with care, only to draw attention when another vessel is not showing the lights required.
✗
Question 22. Within what period after embarkation must passenger ships conduct a muster and drill for passengers?
Your Answer: (Not answered)
Correct Answer: B (Within 24 hours)
💡 SOLAS III requires a muster and drill for passengers within 24 hours of embarkation so that passengers are familiar with their duties and muster stations.
✗
Question 23. What action do SOLAS and STCW require if the main engine fails while under way?
Your Answer: (Not answered)
Correct Answer: A (Notify the bridge immediately, display the appropriate lights, shapes or sound signals and take action such as anchoring or other avoidance measures)
💡 Engine failure deprives the ship of manoeuvrability. The bridge must be informed at once, the lights, shapes or signals for a vessel not under command displayed, and measures such as anchoring taken to avoid collision, with the authorities informed.
✗
Question 24. What time limits apply to launching and recovering a rescue boat?
Your Answer: (Not answered)
Correct Answer: B (Launching and recovery, when loaded, each within 5 minutes)
💡 Launching and recovery when fully loaded shall each be within 5 minutes.
✗
Question 25. What does SOLAS address regarding resetting fire detection alarms?
Your Answer: (Not answered)
Correct Answer: A (Alarms should be reset only after the fire condition has been cleared, preventing the mask of a real fire by careless resetting)
💡 SOLAS requires detection alarms to be reset only after the fire condition has been dealt with, preventing the watchkeeper from resetting alarms merely to silence them and thereby concealing a real fire with serious consequences.
✗
Question 26. What does SOLAS address regarding fixed fire detection in ro-ro spaces?
Your Answer: (Not answered)
Correct Answer: B (A fixed fire detection and fire alarm system capable of detecting a fire in the vehicle space promptly)
💡 SOLAS requires ro-ro and vehicle spaces to have a fixed fire detection and fire alarm system. Because these spaces are large and vehicles carry fuel, fire spreads rapidly, and periodic rounds alone would not detect it in time.
✗
Question 27. Should satellite positioning fail, the vessel relies on which alternative means?
Your Answer: (Not answered)
Correct Answer: A (Compass bearings together with chart observation)
💡 Traditional observation with compasses and charts remains the fall-back means.
✗
Question 28. A cargo ship is 140 m in length with a crew of 20. What capacity must the survival craft on each side provide under SOLAS III/31?
Your Answer: (Not answered)
Correct Answer: D (Each side must accommodate all 20 persons on board)
💡 SOLAS III/31 requires the survival craft on each side of a cargo ship to accommodate all persons on board, so that everyone can escape whichever side is unusable. Counting the total for both sides only is not sufficient.
✗
Question 29. From where may the ventilation openings of machinery spaces be closed?
Your Answer: (Not answered)
Correct Answer: A (From outside the machinery space)
💡 SOLAS II-2/9: ventilation openings shall be capable of being closed from outside the space.
✗
Question 30. For a cargo ship of 100 m and above, the number of lifebuoys with self-igniting lights shall be not less than:
Your Answer: (Not answered)
Correct Answer: B (8)
💡 SOLAS III/32 requires not less than eight lifebuoys with self-igniting lights for cargo ships of 100 m and above.
✗
Question 31. An emergency generator starts in 60 seconds. What is the SOLAS requirement?
Your Answer: (Not answered)
Correct Answer: A (Within 45 seconds; 60 seconds does not comply)
💡 SOLAS II-1/41 requires the emergency generator to start automatically and connect to the emergency switchboard within 45 seconds of the main source failing. Sixty seconds exceeds the limit and requires adjustment or repair.
✗
Question 32. What risk does SOLAS address regarding the height of side scuttles in the shell?
Your Answer: (Not answered)
Correct Answer: B (A scuttle set too low may become immersed on list or when shipping seas, allowing water entry)
💡 SOLAS limits the permitted positions of side scuttles and shell openings. A low position may become immersed on list, trim or when shipping seas, allowing water entry; such openings must be considered in subdivision and stability calculations.
✗
Question 33. What is the purpose of the transmitting heading device on board?
Your Answer: (Not answered)
Correct Answer: D (To distribute the heading signal from the gyro compass to radar, AIS and similar equipment)
💡 The transmitting heading device supplies the heading to radar, AIS, ECDIS and other equipment, ensuring consistent heading data and avoiding errors in control and display.
✗
Question 34. A 120 m cargo ship has one lifeboat on each side. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: B (The capacity on each side must accommodate all persons, with at least one boat serving as a rescue boat)
💡 SOLAS requires the capacity on each side of a cargo ship to accommodate all persons on board, with at least one boat meeting the rescue boat requirements. Counting the two boats together would not ensure escape if one side were lost.
✗
Question 35. What should be done after a water ingress alarm on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (Identify the flooded hold, assess the effect on stability and strength and take measures such as pumping or adjustment, reporting as required)
💡 On a water ingress alarm the flooded hold and the cause should be established at once, such as hatch leakage, hull damage or piping leakage, the effect on stability, strength and draught assessed and measures taken such as pumping, adjusting ballast or reducing cargo, with the company and the Administration informed under the SMS.
✗
Question 36. When a deficiency found in a PSC inspection is judged to be a non-detainable one, how is it normally handled?
Your Answer: (Not answered)
Correct Answer: B (Rectify within the specified period, generally without affecting departure, keeping evidence of rectification)
💡 A non-detainable deficiency is normally required to be rectified within the specified period, before departure or subsequently, and does not necessarily lead to detention, but the ship should keep evidence of rectification such as photographs, repair records and service reports for re-inspection and future checks. A detainable deficiency must be rectified before departure.
✗
Question 37. What are the approval and use requirements for the Cargo Securing Manual?
Your Answer: (Not answered)
Correct Answer: C (It should be approved by the Administration and carried on board, the crew securing cargo and inspecting the securing equipment as it requires)
💡 Under SOLAS V/5 and related requirements the relevant ships should carry a Cargo Securing Manual approved by the Administration, containing the list, strength, arrangement and use of the securing devices, the crew securing cargo as it requires and inspecting and maintaining the equipment at the required intervals, recording defects and repairs.
✗
Question 38. During a PSC inspection the lifeboat engine is started and fails several times in a row. The finding is?
Your Answer: (Not answered)
Correct Answer: B (The lifeboat cannot be used reliably, a serious deficiency that may lead to detention)
💡 A lifeboat engine should start reliably at any time, being essential for manoeuvring and clearing the casualty after abandonment. Repeated failure shows the lifeboat cannot be reliably put into use, a deficiency seriously affecting life-saving capability that may normally lead to detention.
✗
Question 39. The isolating valve on the fire main serving the accommodation side has long been seized and cannot be operated. How should this be judged?
Your Answer: (Not answered)
Correct Answer: D (Fire main isolating valves must be operable at all times; being seized is a deficiency affecting the isolating function)
💡 Isolating valves on the fire main are used to isolate a damaged section of piping so that the rest of the system still receives water. They must be capable of manual operation at all times. Being seized deprives them of their isolating function and is a deficiency affecting the reliability of the firefighting system, which should be rectified.
✗
Question 40. What is the principal safety hazard of a fixed CO2 system?
Your Answer: (Not answered)
Correct Answer: B (Asphyxiation of personnel)
💡 CO2 displaces oxygen, so personnel must be clear and alarms given before release.
✗
Question 41. The fire main pressure gauge shows an abnormally low pressure. What is the concern?
Your Answer: (Not answered)
Correct Answer: C (It may indicate reduced pump performance, leakage or a valve not properly opened and the cause should be established)
💡 Abnormally low pressure in the fire main may result from reduced fire pump performance, leakage in the piping or valves, a valve not correctly opened or a problem on the suction side. It would mean insufficient pressure at the jets in a fire, so the cause should be established and dealt with at once, as this is a deficiency that may affect firefighting capability.
✗
Question 42. In machinery spaces, at least how many portable fire extinguishers shall be provided near each hydrant?
Your Answer: (Not answered)
Correct Answer: D (1)
💡 SOLAS II-2/10 requires at least one portable fire extinguisher near each hydrant in machinery spaces.
✗
Question 43. What is required for escape routes in an emergency?
Your Answer: (Not answered)
Correct Answer: C (They must be usable in fire and smoke, with low level lighting, kept clear and doors openable from inside without a key)
💡 SOLAS requires escape routes to be designed and arranged to remain usable in a fire, with low level lighting enabling the direction to be seen in dense smoke, the route kept clear and doors openable from inside without a key, so that personnel can evacuate safely.
✗
Question 44. A self-igniting light on a lifebuoy is found inoperative because its battery has failed. The finding is?
Your Answer: (Not answered)
Correct Answer: C (The lifebuoy has lost its night-marking capability, a life-saving equipment deficiency to be replaced)
💡 The self-igniting light is used at night to mark the position of a person overboard and is a key attachment of the lifebuoy. A failed battery makes the lifebuoy unidentifiable at night. This is a functional deficiency of life-saving equipment; the battery or light should be replaced so that it is always ready for use.
✗
Question 45. Trading at high latitudes: what more does the radio installation need?
Your Answer: (Not answered)
Correct Answer: B (alerting and watch resting chiefly on high and medium frequencies, the beacon being one that works through polar-orbiting satellites)
💡 Those waters lie outside the view of a geostationary satellite, so distress alerting and the safety traffic fall mainly on digital selective calling in the medium and high frequencies, and maritime safety information comes by narrow-band direct printing on high frequencies, receivers being required to work there. The beacon depends on the polar-orbiting system, so its fit and its stowage are settled with a high-latitude alert in mind. Beyond the gear itself: propagation in those frequencies changes with the hour and with solar activity, an antenna can fail under ice, and the run from the bridge to that antenna matters. The equipment list, the frequencies watched and the back-ups, a usable source of power and a second means of alerting among them, are checked against the radio record and the certificates rather than judged from experience earned further south or north.
✗
Question 46. What do SOLAS and good practice address regarding stability in the ballast condition?
Your Answer: (Not answered)
Correct Answer: A (The centre of gravity is relatively high and the initial metacentric height may be small, requiring particular attention to intact stability)
💡 In the ballast condition the draught is small, the windage relatively large and the righting capability limited. Improper ballasting may cause insufficient stability or the propeller to break surface, so the intact stability of the ballast condition must be calculated separately and meet the criteria.
✗
Question 47. What cleanliness and dryness is required of holds before loading a bulk carrier?
Your Answer: (Not answered)
Correct Answer: B (Holds to be clean, dry and free of residues from the previous cargo, preventing contamination and chemical reaction)
💡 Before loading a bulk carrier the holds should be confirmed clean, dry and free of smell and residues from the previous cargo, such as rust, oil and chemical traces, preventing contamination or reaction with residues producing harmful gas and self-heating. There should be no standing water or refuse.
✗
Question 48. A Cargo Ship Safety Certificate (combined) shall be issued for a period not exceeding:
Your Answer: (Not answered)
Correct Answer: D (5 years)
💡 SOLAS I/12 allows a combined Cargo Ship Safety Certificate for a period not exceeding 5 years.
✗
Question 49. Which statement about the discharge of plastic wastes is correct?
Your Answer: (Not answered)
Correct Answer: C (All plastics, including synthetic ropes, plastic refuse bags and incinerator ash residues, are prohibited from discharge)
💡 Under MARPOL Annex V all plastics are prohibited from discharge into the sea, including synthetic ropes, synthetic fishing gear, plastic refuse bags and incinerator ash containing plastics. This is the strictest prohibition in Annex V and a breach is a serious violation.
✗
Question 50. What should be noted about the use of distress signals during drills?
Your Answer: (Not answered)
Correct Answer: A (Signals should not be fired in a drill unless necessary; if fired, the direction and safety must be confirmed and the matter recorded)
💡 Distress signals are dangerous goods with a limited life. They are not normally fired in a drill, alternative means being used to check them. If firing is genuinely required, the direction and the safety of the surroundings must be confirmed, the bridge informed and the expenditure recorded, avoiding misunderstanding or danger.
✗
Question 51. How many SARTs must a ship normally carry under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Two, normally sited on either side of the bridge for rapid access)
💡 SOLAS IV/7 requires two SARTs on cargo ships of 300 GT and above, normally sited on either side of the bridge for rapid access. A single SART cannot serve rescuing vessels approaching from either side.
✗
Question 52. The ship shall carry for dangerous goods:
Your Answer: (Not answered)
Correct Answer: A (a list or manifest giving the name, class and location of the goods)
💡 SOLAS VII/5 requires a special list or manifest giving the name, class and location of the dangerous goods.
✗
Question 53. What is the minimum number of firefighter's outfits for a cargo ship?
Your Answer: (Not answered)
Correct Answer: A (At least two)
💡 Under SOLAS II-2/10 a cargo ship should carry at least two firefighter's outfits, comprising protective clothing, boots, gloves, a rigid helmet, a safety lamp and an axe, with tankers requiring more as specified. Insufficient provision weakens the ability to enter a fire area.
✗
Question 54. Which satellite communication equipment must a ship in sea area A3 carry?
Your Answer: (Not answered)
Correct Answer: B (An Inmarsat ship earth station (SES))
💡 Sea area A3 lies within Inmarsat coverage, so an Inmarsat ship earth station is required. MF/HF is the principal means in sea area A4.
✗
Question 55. What is required regarding toolbox meetings?
Your Answer: (Not answered)
Correct Answer: C (A short meeting before starting work to confirm the task, risks, duties and safety measures)
💡 The ISM Code and good practice require a toolbox meeting before work starts, particularly for high risk or complex work, at which the person in charge explains the task, the risks identified, the safety measures, the allocation of duties and the emergency arrangements and confirms that those taking part understand them, preventing accidents from inadequate communication.
✗
Question 56. What must be checked on board when loading containers under SOLAS and the CSS Code?
Your Answer: (Not answered)
Correct Answer: D (The weight, position and securing of containers, preventing structural damage or securing failure from overweight boxes)
💡 SOLAS VI/2 requires the declared weight of containers to be verified against actual weight and securing carried out in accordance with the securing manual. Overweight boxes or improper securing cause structural damage and loss of cargo overboard.
✗
Question 57. How does the position of the centre of gravity affect cargo stowage?
Your Answer: (Not answered)
Correct Answer: D (The higher the cargo, the higher the centre of gravity, the smaller the initial metacentric height and the poorer the stability; cargo should not be concentrated high)
💡 The higher the cargo, the higher the ship's centre of gravity, the smaller the initial metacentric height and the less the reserve of stability, making capsize more likely in rough weather. Stowage should avoid concentrating cargo high up, particularly on a tween deck, and the resulting height of the centre of gravity should be checked against the permissible value.
✗
Question 58. The oil discharge monitoring equipment (ODM) is found not to have recorded as required during the voyage. The finding is?
Your Answer: (Not answered)
Correct Answer: B (The ODM must continuously monitor and record as required; failure to record is an operational and record deficiency)
💡 A tanker oil discharge monitoring equipment should continuously monitor the discharge and record the quantity discharged and the instantaneous rate as proof of a compliant discharge. Failure to record makes compliance unprovable. It is an operational and record deficiency to be corrected.
✗
Question 59. Which VHF channel is used for distress and safety radiotelephony?
Your Answer: (Not answered)
Correct Answer: A (Channel 16 (156.8 MHz))
💡 VHF channel 16 (156.8 MHz) is for distress and safety radiotelephony. Channel 70 is reserved for DSC calling and must not be used for speech.
✗
Question 60. Electrical equipment in a hazardous area: on what is the selection made?
Your Answer: (Not answered)
Correct Answer: B (matched to the zone in type of protection and temperature class, that protection surviving maintenance)
💡 The choice rests on two things: the classification of the space, and how easily the gas or vapour there can be lit. Zones run by how often a flammable mixture may appear, equipment by type of protection and temperature class, the marking on its certificate covering the zone it is put into and its temperature class staying below the ignition temperature of what may be there. After installation, maintenance can undo all of it: a bolt left out, a flame path scored, a wrong cable gland, a housing not made by the original maker, and a certified item is uncertified in the place that matters. Testing the atmosphere before hot work or entry is a separate defence and does not substitute for the selection.
✗
Question 61. Where should the fire control plan be stowed on board?
Your Answer: (Not answered)
Correct Answer: B (In a conspicuously marked weathertight enclosure outside the deckhouse, with a further copy on the bridge or equivalent position)
💡 SOLAS II-2/15 requires the fire control plan to be permanently stowed in a conspicuously marked weathertight enclosure outside the deckhouse, with another copy on the bridge or equivalent, for use by shore firefighters.
✗
Question 62. The launching appliance for survival craft shall:
Your Answer: (Not answered)
Correct Answer: A (be capable of controlled lowering to ensure safe water entry)
💡 SOLAS III/16 requires the launching appliance to lower survival craft under control for a safe water entry.
✗
Question 63. What is the minimum number of radar transponders (SARTs) for a cargo ship of 500 gross tonnage and above?
Your Answer: (Not answered)
Correct Answer: D (Two, one on each side)
💡 Under SOLAS IV/7 a cargo ship of five hundred gross tonnage and above should carry at least two radar transponders, normally one on each side, so that one can be taken into the survival craft on either side during abandonment. The SART marks the distress position on the radar.
✗
Question 64. Where shall the collision bulkhead be fitted and why?
Your Answer: (Not answered)
Correct Answer: B (Forward, to confine flooding from bow damage)
💡 The collision bulkhead limits flooding to the forward region after a collision.
✗
Question 65. What is the basic SOLAS II-1/42 requirement for the location of the emergency generator and its prime mover?
Your Answer: (Not answered)
Correct Answer: C (Outside category A machinery spaces, with an independent fuel supply)
💡 SOLAS II-1/42 requires the emergency source of power to be located outside category A machinery spaces so it remains available if that space is on fire, with a separate fuel supply.
✗
Question 66. What shall the Ship Security Plan contain?
Your Answer: (Not answered)
Correct Answer: B (Security organisation, duties, measures and training)
💡 Security organisation, duties, protective measures and training.
✗
Question 67. What does SOLAS address regarding the position of survival craft relative to the propulsion plant?
Your Answer: (Not answered)
Correct Answer: D (Stowed as far as practicable from the propulsion plant and other hazardous areas, avoiding interference from propellers or exhaust)
💡 SOLAS requires survival craft to be stowed as far as practicable from the propellers, thrusters and exhaust areas, preventing injury to persons or damage to the craft during launching, and allowing safe launching even while the ship still has headway.
✗
Question 68. What is the basic SOLAS II-1 requirement for the position of the collision bulkhead on a cargo ship?
Your Answer: (Not answered)
Correct Answer: A (At a distance from the forward perpendicular of not less than 5 per cent of the ship's length, or 10 m, whichever is the less)
💡 SOLAS II-1 requires the collision bulkhead to be not less than 5 per cent of the ship's length or 10 m, whichever is less, from the forward perpendicular, so that flooding forward protects the spaces abaft.
✗
Question 69. How must operating instructions and markings for equipment be managed?
Your Answer: (Not answered)
Correct Answer: B (Clear instructions and warnings, available near the equipment and kept in good condition)
💡 Operating instructions and warning markings for critical equipment should be provided near the equipment, clear and in good condition, not fallen off or illegible, so that the operator can consult them at any time. Relying on memory without markings makes errors likely after a change of personnel or under pressure.
✗
Question 70. What does the ISM Code require regarding retention of documents and records?
Your Answer: (Not answered)
Correct Answer: A (Retained for the prescribed periods, able to demonstrate the effective operation of the system and available for inspection)
💡 ISM Code 11 requires documents and records such as those of training, maintenance, drills and audits to be retained for the prescribed periods, demonstrating the effective operation of the system and available for reference and inspection when needed.
✗
Question 71. Which of the following is NOT part of an abandon ship drill under SOLAS III/19?
Your Answer: (Not answered)
Correct Answer: C (Checking crew wage and leave records)
💡 SOLAS III/19 lists summoning of persons, checking dress and lifejackets, briefing and operation of launching appliances and checking equipment readiness. Wage and leave records are not part of a drill.
✗
Question 72. What is examined during a PSC inspection of a galley fixed extinguishing system?
Your Answer: (Not answered)
Correct Answer: C (Whether the system is operational, whether nozzles are clear and whether the release control is marked)
💡 A galley fixed extinguishing system should be checked for being operational, with pressure or weight correct, nozzles clear of grease and the release control clearly marked and operable. An appearance check alone would not reveal a failed system.
✗
Question 73. On what basis may the Administration issue an exempted certificate?
Your Answer: (Not answered)
Correct Answer: A (Where the ship's particular voyage makes compliance unreasonable, provided the conditions are safe and consistent with the purpose of the Convention)
💡 SOLAS I/12 permits an exemption where the ship is not engaged on an international voyage and the circumstances of the voyage make compliance unreasonable or unnecessary, provided safety is assured.
✗
Question 74. What should be noted when using VHF for port communication?
Your Answer: (Not answered)
Correct Answer: A (Use the designated port channels, keep transmissions concise and end them promptly, maintaining a watch on channel 16)
💡 Port communication should use the designated channels, such as the berthing, pilot and VTS frequencies, with concise standard phraseology and transmissions ended promptly, while a watch is kept on channel 16 for distress and safety traffic. Channel 16 must not be occupied at length.
✗
Question 75. The sewage treatment plant is found not in operation and untreated sewage is being discharged directly. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Discharging untreated sewage does not meet the rules, a pollution prevention deficiency)
💡 Discharge of sewage must meet the applicable rules, that is, be treated by an approved treatment plant and meet the discharge conditions, or be discharged as permitted beyond the specified distance. Direct discharge of untreated sewage with the plant not running does not meet pollution prevention requirements and is a deficiency to be corrected.
✗
Question 76. Which Convention governs the ship's handling of ballast water?
Your Answer: (Not answered)
Correct Answer: B (The Ballast Water Management Convention)
💡 Ballast water is to be managed under the Ballast Water Management Convention.
✗
Question 77. What should the safety training of crew cover?
Your Answer: (Not answered)
Correct Answer: B (Safety awareness, shipboard and job specific training, emergency duties and equipment operation, risk assessment and permit to work systems)
💡 The ISM Code and STCW require crew safety training to cover safety awareness, shipboard and job specific training including familiarisation with duties and equipment, emergency duties and the operation of life-saving and firefighting equipment, risk assessment and permit to work systems, with familiarisation arranged for newly joined and transferred personnel.
✗
Question 78. The bow structure requirements for bulk carriers mainly address:
Your Answer: (Not answered)
Correct Answer: B (carriage of high-density solid bulk cargoes such as ore)
💡 SOLAS XII/9: the bow structure requirements address the carriage of high-density solid bulk cargoes such as ore.
✗
Question 79. How does the number of firefighter's outfits differ between tankers and ordinary cargo ships?
Your Answer: (Not answered)
Correct Answer: B (Tankers normally require four outfits, ordinary cargo ships two)
💡 SOLAS II-2/10.10 requires at least two firefighter's outfits on cargo ships of 1000 GT and above. Tankers must carry additional outfits, normally four in total, with extra breathing apparatus.
✗
Question 80. What does SOLAS require regarding the receipt of navigational warnings and meteorological information at sea?
Your Answer: (Not answered)
Correct Answer: D (They must be received and processed continuously by the prescribed means, with timely assessment of their effect on the voyage)
💡 SOLAS V requires continuous reception of navigational warnings and weather information by the appropriate means, with the watchkeeper assessing their effect on route and speed and acting accordingly.
✗
Question 81. When is a Declaration of Security concluded?
Your Answer: (Not answered)
Correct Answer: D (When security levels differ between ship and port facility, or the interface risk is high)
💡 ISPS Code A/5: a DoS is concluded when levels differ or the security risk at the interface is high.
✗
Question 82. If a DSC alert in sea area A1 receives no response, what does GMDSS procedure require?
Your Answer: (Not answered)
Correct Answer: C (Make a radiotelephony distress call on VHF channel 16 and try other means available)
💡 If a DSC alert is not acknowledged, a radiotelephony distress call should be made on VHF channel 16 or MF 2182 kHz, at the same time or afterwards, and other means such as satellite or HF tried, ensuring the alert is received. Channel 70 must not be used for speech.
✗
Question 83. What does SOLAS VI/1 require regarding cargo information before loading ordinary cargo?
Your Answer: (Not answered)
Correct Answer: B (The shipper must provide the necessary information about the cargo before loading, so the master can judge its suitability for safe carriage)
💡 SOLAS VI/1 requires the shipper to give the master the necessary information about the cargo before loading, enabling him to judge suitability for safe carriage and the precautions needed. Experience alone or later submission does not comply.
✗
Question 84. An escape route in the engine room is found permanently blocked by stores. The finding is?
Your Answer: (Not answered)
Correct Answer: C (Escape routes must be kept clear; blockage seriously affects emergency evacuation, a serious deficiency)
💡 A machinery space should have two escape routes as widely separated as practicable, always available. A blocked escape route endangers the evacuation of engine room personnel in a fire or other emergency. It is a serious deficiency affecting personnel safety and the obstruction should be removed at once.
✗
Question 85. How must cable penetrations of fire divisions be treated under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (They must be sealed to maintain the original fire and smoke integrity of the division)
💡 SOLAS requires approved penetration seals where cables pass through class A or B divisions, maintaining fire and smoke integrity. Cotton waste or loose packing provides no fire resistance.
✗
Question 86. The collision bulkhead shall be located at a distance from the forward perpendicular of not less than:
Your Answer: (Not answered)
Correct Answer: D (0.05L or 10 m, whichever is less)
💡 SOLAS II-1/12 requires the collision bulkhead to be located not less than 0.05L or 10 m (whichever is less) from the forward perpendicular, and not more than 0.08L.
✗
Question 87. A fixed detection system was tested with smoke. What action must follow detection under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (An audible and visual alarm on the bridge or at the control station, indicating the space concerned)
💡 SOLAS requires detection to produce an audible and visual alarm on the bridge or at a continuously manned control station and to indicate the space involved. Automatic discharge is not necessarily required.
✗
Question 88. What does SOLAS address regarding the combustibility of curtains and decorative materials in accommodation?
Your Answer: (Not answered)
Correct Answer: D (Their combustibility must be restricted, using flame retardant or treated materials)
💡 SOLAS places requirements on the combustibility of curtains, carpets and decorative materials in accommodation spaces, requiring flame retardant or treated materials to prevent fire from spreading rapidly along them.
✗
Question 89. What is required for the maintenance of water ingress detectors on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: B (Tested at regular intervals and kept operational, with tests and maintenance recorded)
💡 SOLAS requires the water ingress detection system of a bulk carrier to be tested and maintained at regular intervals with records kept, so that it alarms reliably when flooding occurs. Long neglect of testing means the system may fail unnoticed.
✗
Question 90. In addition to one per person, passenger ships shall carry:
Your Answer: (Not answered)
Correct Answer: A (an additional appropriate number of lifejackets for watchkeeping and other personnel)
💡 SOLAS III/7 requires passenger ships to carry additional lifejackets for watchkeeping personnel and those at muster stations.
✗
Question 91. In restricted visibility, which measure is NOT in accordance with SOLAS?
Your Answer: (Not answered)
Correct Answer: D (accelerate to pass through quickly)
💡 SOLAS V/8: in restricted visibility measures such as reducing speed, using radar and keeping a proper lookout shall be taken; accelerating is not permitted.
✗
Question 92. Annual verification of a Document of Compliance shall be carried out:
Your Answer: (Not answered)
Correct Answer: C (within the prescribed period around each anniversary date)
💡 SOLAS IX/4 (ISM) requires annual verification within the prescribed window around the anniversary date.
✗
Question 93. What is the purpose of a loading instrument on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Computing hull strength and stability at each stage of loading)
💡 Computing hull strength and stability at each stage of loading and discharging.
✗
Question 94. Earthing of electrical equipment on board serves to:
Your Answer: (Not answered)
Correct Answer: C (Prevent electric shock and leakage)
💡 Earthing protects against electric shock and leakage causing fire.
✗
Question 95. Bulk carriers of 150 m and above must be fitted with a loading instrument. What is its purpose?
Your Answer: (Not answered)
Correct Answer: A (To calculate hull stress and intact stability during loading and unloading)
💡 SOLAS XII/11 requires the loading instrument for calculating hull stresses and intact stability during cargo work, preventing structural damage from overloading or incorrect sequence. Water level detection is a separate requirement.
✗
Question 96. What calibration is required for portable gas detectors?
Your Answer: (Not answered)
Correct Answer: C (Calibrated at the prescribed intervals with a functional test before each use and records kept)
💡 SOLAS and the manufacturers require portable gas detectors to be calibrated at the prescribed intervals, normally not exceeding 12 months, with a functional test including zero and span checks before each use and records kept. Readings from an uncalibrated instrument cannot be trusted, and a wrong appreciation can be fatal.
✗
Question 97. Ships shall be provided with heading indication by means of:
Your Answer: (Not answered)
Correct Answer: D (a gyro-compass or magnetic compass providing heading indication on the bridge)
💡 SOLAS V/19 requires heading indication equipment providing heading to the bridge.
✗
Question 98. What checking of rations in lifeboats is required?
Your Answer: (Not answered)
Correct Answer: B (Check the packaging is sound and the rations are within date, replacing them if not)
💡 Lifeboat rations should be checked for sound packaging, free of damage or damp, and for being within their expiry date, with any failing replaced at once. Expired or damp rations provide no nourishment after abandonment and may even cause illness. It is a common deficiency.
✗
Question 99. What is required for manholes and flush covers in the freeboard deck?
Your Answer: (Not answered)
Correct Answer: C (Kept closed and secured, preventing sea water entering spaces below when the deck is swept)
💡 SOLAS and the Load Line Convention require manholes and flush covers in the freeboard deck leading to spaces below to be kept closed and secured, with gaskets and fastenings, preventing sea water from entering when the deck is swept or the ship lists. A simple plate is not watertight.
✗
Question 100. What does SOLAS specifically require regarding the correction of nautical charts and publications?
Your Answer: (Not answered)
Correct Answer: B (They must be corrected promptly from notices to mariners, with a record of the corrections kept)
💡 SOLAS V/27 requires charts and nautical publications to be corrected promptly from notices to mariners with a record kept, such as a chart correction log. Late or missing correction is a common ground for detention.