Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. What does SOLAS address regarding updating structural strength information for a bulk carrier?
Your Answer: (Not answered)
Correct Answer: D (Updated promptly and approved when the structure or loading limitations change)
💡 SOLAS requires the structural strength and loading limitation information of a bulk carrier to be updated promptly and approved by the classification society or the Administration when the structure, equipment or loading conditions change significantly. The crew must not modify it themselves.
✗
Question 2. What is the scope of the term 'ship' in SOLAS?
Your Answer: (Not answered)
Correct Answer: B (Any ship engaged on international voyages, with exclusions such as warships and some small cargo ships)
💡 SOLAS applies to ships on international voyages, with stated exclusions for warships and certain small cargo ships.
✗
Question 3. What are the handling requirements when encountering heavy swell and seas?
Your Answer: (Not answered)
Correct Answer: A (Adjust course and speed so that the hull meets the seas at a suitable angle, avoiding a beam sea and direct head seas which cause damage)
💡 In heavy seas and swell the course and speed should be adjusted so the hull meets the seas at a suitable angle, normally obliquely, avoiding a beam sea which causes heavy rolling and cargo shift and direct head seas which cause violent pitching and slamming that damages the hull.
✗
Question 4. A paint locker shall be located behind:
Your Answer: (Not answered)
Correct Answer: B (A class divisions, with independent ventilation and extinguishing arrangements)
💡 SOLAS II-2/9 requires paint lockers to be bounded by A class divisions with independent ventilation and extinguishing.
✗
Question 5. What identification is required for fire main isolation valves?
Your Answer: (Not answered)
Correct Answer: A (Clear marking of their position and direction of operation, enabling prompt and correct action in a fire)
💡 SOLAS requires fire main isolation valves to be clearly marked as to position and direction of operation, so that in an emergency the crew can find them quickly and correctly isolate the section affected. Missing or wrong marking delays firefighting.
✗
Question 6. An inert gas system shall be used:
Your Answer: (Not answered)
Correct Answer: A (to maintain cargo tanks inert during cargo operations, ballasting and while at sea)
💡 SOLAS II-2/5: the inert gas system shall be used to maintain cargo tanks inert during cargo operations, ballasting and while at sea.
✗
Question 7. What are the updating requirements for AIS voyage related information?
Your Answer: (Not answered)
Correct Answer: B (Entered at the start of the voyage and updated as soon as the information, such as destination, changes)
💡 AIS voyage related information such as draught, cargo, destination and ETA must be entered at the start of the voyage and updated promptly when it changes. Stale data misleads other ships and shore stations.
✗
Question 8. The ISPS Code applies to:
Your Answer: (Not answered)
Correct Answer: A (passenger ships and cargo ships of 500 GT and above engaged on international voyages)
💡 SOLAS XI-2/3: the ISPS Code applies to passenger ships and cargo ships of 500 GT and above engaged on international voyages.
✗
Question 9. What should be done if abnormal heel develops during cargo operations?
Your Answer: (Not answered)
Correct Answer: D (Stop work at once, establish the cause such as cargo shift, flooding or uneven ballast, and then decide the course of action)
💡 If abnormal heel develops during cargo work, operations should stop immediately and the cause established, whether cargo has shifted, a compartment is flooding or the ballast is uneven, with stability and structural condition assessed before deciding what to do. Continuing could allow the heel to increase rapidly and cause capsize.
✗
Question 10. What shall the design of the bridge windows ensure?
Your Answer: (Not answered)
Correct Answer: A (The officer on watch can see the forward seaway and the ship's vicinity)
💡 SOLAS V/22: the bridge must permit a good all-round view from the conning position.
✗
Question 11. What does SOLAS address regarding the position of survival craft relative to the propulsion plant?
Your Answer: (Not answered)
Correct Answer: D (Stowed as far as practicable from the propulsion plant and other hazardous areas, avoiding interference from propellers or exhaust)
💡 SOLAS requires survival craft to be stowed as far as practicable from the propellers, thrusters and exhaust areas, preventing injury to persons or damage to the craft during launching, and allowing safe launching even while the ship still has headway.
✗
Question 12. On what is the safe speed a ship should be carrying at a given moment determined?
Your Answer: (Not answered)
Correct Answer: D (speed settled by visibility, traffic density, manoeuvring performance, wind and sea, draught and background light, so that the ship can stop in the distance appropriate to the conditions)
💡 Rule 6 makes safe speed a capability rather than a figure: ability to stop within the distance appropriate to the conditions and to take effective collision action. Visibility, traffic density, the ship's own stopping distance and turning ability, background lighting by night, wind, sea and rain, draught against the available depth, all count, and engines must be ready in a narrow channel or in fog. A port limit is an extra constraint: keeping under it is not the same as keeping Rule 6, and keeping Rule 6 may call for less than the limit.
✗
Question 13. A ship's AIS is found switched off while under way. The finding is?
Your Answer: (Not answered)
Correct Answer: B (AIS must be kept in operation as required and may be switched off only in the specified circumstances; failing to keep it on is a violation)
💡 The AIS should be kept in operation as required and may be switched off only in the specific cases permitted by the rules, such as where continuous operation would compromise the safety or security of the ship, and the reason should be recorded. Switching it off at will while under way is a violation that may lead to detention and investigation.
✗
Question 14. Where must the valves of the bilge system be operable under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (From a readily accessible position in the machinery space, and by remote operation when required)
💡 SOLAS requires bilge system valves to be arranged for operation from a readily accessible position and to be capable of remote operation where necessary, avoiding the need for personnel to enter a space that may be flooding or on fire.
✗
Question 15. What does SOLAS address regarding the protection of stairway enclosures?
Your Answer: (Not answered)
Correct Answer: D (Stairways must be enclosed by class A or B divisions, preventing a chimney effect from accelerating fire and smoke spread)
💡 SOLAS requires enclosed stairways in accommodation spaces to be protected by class A or B divisions, preventing the stairwell from acting as a chimney that accelerates the upward spread of flame and smoke, and protecting the escape route.
✗
Question 16. A 4200 GT cargo ship on international voyages has three pumps in the machinery space. Under SOLAS II-2/10.2, what is the minimum fire pump arrangement?
Your Answer: (Not answered)
Correct Answer: B (At least two independently driven fire pumps)
💡 SOLAS II-2/10.2 requires cargo ships of 1000 GT and above to have at least two independently driven fire pumps. At 4200 GT the ship is well above the threshold, so two is the minimum.
✗
Question 17. What fire rating does SOLAS normally require for the boundary between a category A machinery space and accommodation spaces?
Your Answer: (Not answered)
Correct Answer: D (A-60 class division)
💡 SOLAS normally requires A-60 class boundaries between category A machinery spaces and accommodation and service spaces because of the high fire risk in machinery spaces.
✗
Question 18. What does SOLAS require as regards the language of certificates?
Your Answer: (Not answered)
Correct Answer: C (They must be drawn up in the official language of the issuing State with a translation into English, French or Spanish)
💡 SOLAS I/5 requires certificates to be in the official language of the issuing State with a translation into English, French or Spanish, so that port States can verify them. A single language alone does not comply.
✗
Question 19. What does SOLAS address regarding automatic and remote control of propulsion machinery?
Your Answer: (Not answered)
Correct Answer: B (The control system must have the necessary alarms, monitoring and protection, retaining basic manoeuvring capability if it fails)
💡 SOLAS requires the control system of the main propulsion machinery to have alarms and monitoring, such as fault and parameter deviation alarms, and to retain basic manoeuvring capability through local control or other means if the control system fails.
✗
Question 20. On receiving a distress alert, a ship shall:
Your Answer: (Not answered)
Correct Answer: B (acknowledge and relay it as appropriate and take necessary assistance action)
💡 SOLAS V/33: a ship receiving a distress alert shall acknowledge and relay it as appropriate and take the necessary assistance action.
✗
Question 21. What is required when life-saving appliances are changed on board?
Your Answer: (Not answered)
Correct Answer: B (Replace with approved equipment of equal or better performance and update the records and certificate attachments)
💡 Life-saving appliances should be replaced with approved equipment of the same or better performance, with the equipment records and certificate attachments such as the record of equipment for the cargo ship safety equipment certificate updated and the classification society informed for verification where necessary.
✗
Question 22. What interval does SOLAS III/20 require for routine inspection of life-saving appliances?
Your Answer: (Not answered)
Correct Answer: C (At least once a week)
💡 SOLAS III/20 requires life-saving appliances to be inspected at least weekly so as to remain ready for use. Monthly inspections are the more detailed visual checks of survival craft and launching appliances.
✗
Question 23. The auxiliary steering gear shall be capable of putting the rudder from 15° on one side to 15° on the other, at half speed, within:
Your Answer: (Not answered)
Correct Answer: A (60 seconds)
💡 SOLAS II-1/29: the auxiliary steering gear shall be capable of the 15°-to-15° rudder movement at half speed within 60 seconds.
✗
Question 24. What does SOLAS address regarding automatic closing of fire dampers?
Your Answer: (Not answered)
Correct Answer: C (Fire dampers where ducts pass through class A divisions must close automatically or by remote control in a fire)
💡 SOLAS requires fire dampers at duct penetrations of class A divisions to close automatically, for example by fusible elements, or by remote control, preventing fire and smoke from spreading through the ventilation system. Manual closing alone is often too late.
✗
Question 25. For the discharge of bilge water treated by an oily water separator, what is the general oil content limit?
Your Answer: (Not answered)
Correct Answer: B (15 parts per million)
💡 Under MARPOL Annex I, bilge water treated by an oily water separator may generally be discharged only if its oil content does not exceed fifteen parts per million, with the 15ppm alarm and automatic stopping device. Tankers are subject to stricter distance and monitoring requirements.
✗
Question 26. What lighting shall survival craft have?
Your Answer: (Not answered)
Correct Answer: B (Their own searchlight and light for night operation)
💡 Survival craft shall be provided with their own lighting for night operation.
✗
Question 27. How many security levels are established under the ISPS Code?
Your Answer: (Not answered)
Correct Answer: A (Three)
💡 The ISPS Code establishes three security levels: 1, 2 and 3.
✗
Question 28. The berth-to-berth principle of voyage planning means that the plan covers:
Your Answer: (Not answered)
Correct Answer: D (the entire passage from berth at the port of departure to berth at the port of destination)
💡 SOLAS V/34 requires a berth-to-berth plan covering all stages of the passage.
✗
Question 29. How does the number of firefighter's outfits differ between tankers and ordinary cargo ships?
Your Answer: (Not answered)
Correct Answer: B (Tankers normally require four outfits, ordinary cargo ships two)
💡 SOLAS II-2/10.10 requires at least two firefighter's outfits on cargo ships of 1000 GT and above. Tankers must carry additional outfits, normally four in total, with extra breathing apparatus.
✗
Question 30. What do SOLAS and good practice address regarding operational testing of a fixed foam system?
Your Answer: (Not answered)
Correct Answer: C (Periodic inspection of piping and nozzles and, as required, a discharge test to confirm the system works)
💡 SOLAS and good practice require periodic inspection of the piping, valves and nozzles of a fixed foam system for obstruction, with a discharge test as required, confirming that the system will operate when needed.
✗
Question 31. What is the principle of assessing stability from the rolling period at sea?
Your Answer: (Not answered)
Correct Answer: D (The rolling period corresponds to the initial metacentric height: a shorter period means excessive stability and a longer one may mean insufficient stability)
💡 The rolling period varies inversely with the square root of the initial metacentric height. A clearly shorter period indicates increased stability from cargo settling or flooding, while a markedly longer period may indicate reduced stability from cargo shifting upwards or flooding. It is a useful aid to judging changes in stability at sea.
✗
Question 32. Where must the remote controls of quick closing valves be located?
Your Answer: (Not answered)
Correct Answer: C (Outside the machinery space in an accessible position, clearly marked)
💡 SOLAS requires the remote controls of quick closing valves to be located outside the machinery space in a readily accessible and clearly marked position, so fuel can be shut off even if the space is on fire and cannot be entered.
✗
Question 33. What is the purpose of the weak link in a liferaft arrangement?
Your Answer: (Not answered)
Correct Answer: D (To part once the raft has inflated and floats, freeing it from the sinking ship)
💡 The weak link has a designed breaking strength so that it parts once the raft has inflated and is lifted by the water, freeing it from the sinking ship. If too strong the raft may be dragged under; if too weak it may part before inflation.
✗
Question 34. A fixed detection system was tested with smoke. What action must follow detection under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (An audible and visual alarm on the bridge or at the control station, indicating the space concerned)
💡 SOLAS requires detection to produce an audible and visual alarm on the bridge or at a continuously manned control station and to indicate the space involved. Automatic discharge is not necessarily required.
✗
Question 35. Which code governs the stability and heeling calculations for grain in bulk?
Your Answer: (Not answered)
Correct Answer: C (the grain code, with its stowage manual and the document of authorisation)
💡 Grain in bulk is dealt with on its own terms: the code gives the assumptions for the heeling caused by grain shifting, the stability criteria and what is required of a hold to be filled with grain, the ship carries a grain stowage manual and an authorisation to carry grain in bulk, and the calculation works out the heeling moment of each hold and checks the stability left after the shift. The solid bulk code answers mineral concentrates and coal, cargoes that may liquefy or react; packaged dangerous goods have their own code; the securing manual is about lashing and the forces in it. The mistake made by mixing the three is to treat grain as an ordinary bulk cargo and so leave out the heeling that comes from surface settlement and slope. Levelling and trimming before loading are done as required, and the booklets with the stability figures go to the master for signature.
✗
Question 36. What is the role of the voyage data recorder in casualty investigation?
Your Answer: (Not answered)
Correct Answer: B (Providing data such as position, course and speed, radar images and bridge audio for investigation)
💡 SOLAS requires the VDR to record navigational and operational data including position, course and speed, radar images, bridge audio and alarms, providing objective evidence for investigation. The data is protected and must not be used at will.
✗
Question 37. What management is required at a crew change?
Your Answer: (Not answered)
Correct Answer: D (Hand over duties and the condition of equipment, provide familiarisation training and update the muster list and related documents)
💡 At a crew change the necessary handover should be completed, covering the duties of the post, the condition of equipment and unfinished matters, familiarisation training arranged for newly joined personnel before they take up duties, the muster list and related documents updated, and the competence and manning of critical positions ensured.
✗
Question 38. Fire is burning in a cargo hold that cannot be entered and whose seat cannot be reached directly. What is the more suitable treatment?
Your Answer: (Not answered)
Correct Answer: D (ventilation and openings of that hold closed, boundary cooling arranged, the fixed system discharged to its design concentration and the space left sealed)
💡 Where the seat cannot be reached the method is to shut off air and keep the agent in the space: ventilation, fire dampers and openings closed, the boundaries and adjacent spaces cooled, the space proved empty, the fixed gas or foam system discharged once at its design concentration, and then left sealed while concentration and bulkhead temperatures are watched. Floodwater on some cargoes worsens the reaction or adds weight and free surface; opening a hatch invites backdraft and injures the party with smoke; injection through a boundary rarely reaches a working concentration.
✗
Question 39. When is the safety signal SECURITE used?
Your Answer: (Not answered)
Correct Answer: C (To broadcast navigational safety information such as a floating hazard or a gale warning)
💡 SECURITE is the safety signal, used to broadcast navigational safety information such as a hazard, a weather warning or a navigational warning. Its priority is lower than MAYDAY and PAN PAN but it is still safety traffic, and unrelated calls must not occupy the frequency.
✗
Question 40. A PSCO checked the gyro compass error. What does SOLAS and the related standards require of the gyro compass?
Your Answer: (Not answered)
Correct Answer: C (It must indicate true north steadily with the error within the prescribed limits while the ship is under way)
💡 SOLAS V/19 requires the gyro compass to indicate true north steadily within prescribed error limits while the ship is under way and rolling, with regular checks and records during the voyage.
✗
Question 41. How should a safety culture be built on board?
Your Answer: (Not answered)
Correct Answer: A (Through leadership by example, open communication, training and encouragement, making safety the crew's own practice)
💡 The effectiveness of a safety management system depends on its culture: the master and officers setting an example, open communication and reporting encouraged, continuous training and encouragement and attention to safety performance, so that safety becomes the crew's own behaviour rather than passive compliance with rules.
✗
Question 42. What is the purpose of the oily water separator arrangement, considering SOLAS and MARPOL?
Your Answer: (Not answered)
Correct Answer: B (To prevent oily bilge water being discharged overboard untreated, requiring treatment to meet the discharge standard)
💡 SOLAS and MARPOL require oily water separation and filtering equipment so that oily bilge water is treated to the prescribed oil content before discharge, preventing pollution of the marine environment.
✗
Question 43. SOLAS requires each ship to be provided with:
Your Answer: (Not answered)
Correct Answer: A (a training manual describing the use of life-saving appliances and survival knowledge)
💡 SOLAS III/35 requires a training manual describing the use of the ship's life-saving appliances and survival knowledge.
✗
Question 44. In what form must the safe working load information for mooring equipment be kept under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (On board in an accessible form identifying each fitting and its safe working load)
💡 SOLAS requires information on the arrangement, identification and safe working load of mooring and towing equipment to be kept on board, such as a mooring arrangement plan and load table, for correct use and inspection.
✗
Question 45. How many means of escape, widely separated, shall be provided on each deck in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: B (Two)
💡 SOLAS II-2/13: at least two widely separated means of escape shall be provided on each deck.
✗
Question 46. How long must dangerous goods documentation be kept on board?
Your Answer: (Not answered)
Correct Answer: A (For the prescribed period, normally until some time after discharge at the port of destination, for traceability and investigation)
💡 The documentation for dangerous goods, the manifest, stowage plan and special cargo information, must be retained for the prescribed period, normally until a certain time after discharge at the port of destination depending on the rules, so that the nature and stowage of the goods can be traced in the event of an incident or pollution.
✗
Question 47. What should be noted when using HF for long range communication?
Your Answer: (Not answered)
Correct Answer: C (Choose the appropriate band according to time and distance, taking account of ionospheric conditions, and establish contact after a test call)
💡 HF communication relies on ionospheric reflection, and the suitable band differs by day and night and with distance, higher bands by day and lower bands at night. Contact should be established after the prescribed test call with the frequency watched. A single fixed frequency often means no contact at all.
✗
Question 48. What does SOLAS XII require regarding the sequence of loading or unloading bulk carriers?
Your Answer: (Not answered)
Correct Answer: A (An approved sequence complying with structural strength limitations must be used)
💡 SOLAS XII requires loading and unloading to follow an approved sequence within structural limits. Skipping holds or working for speed alone can overstress the hull.
✗
Question 49. What do SOLAS and good practice address regarding emergency stopping of the main engine?
Your Answer: (Not answered)
Correct Answer: C (Means for emergency stopping must be provided on the bridge and in the machinery space, operable rapidly in an emergency)
💡 SOLAS and good practice require means for emergency stopping of the main engine, operable quickly from the bridge or the machinery space, preventing an incident from escalating when the propeller is fouled, a person is in the water nearby, or machinery behaves abnormally.
✗
Question 50. Who issues the container packing certificate?
Your Answer: (Not answered)
Correct Answer: C (The person or organization responsible for packing)
💡 The person or organization responsible for packing.
✗
Question 51. In what circumstances must the master take over the conning of the ship?
Your Answer: (Not answered)
Correct Answer: D (Whenever the master judges that conditions or circumstances require him to take over personally)
💡 Under STCW and SOLAS, the master takes over whenever he considers it necessary, such as in narrow channels, dense traffic, heavy weather, restricted visibility or when berthing. It is his judgement.
✗
Question 52. What does SOLAS Chapter IX apply to?
Your Answer: (Not answered)
Correct Answer: C (Passenger ships and cargo ships of 500 GT and above, among others)
💡 Passenger ships and cargo ships of 500 GT and above, among others.
✗
Question 53. What is the role of draught survey during loading and unloading of a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Determining the cargo quantity from draught readings, with attention to the effect of hull deformation)
💡 A draught survey determines cargo quantity from forward, midship and after draughts. Because a bulk carrier's hull deforms during cargo work, readings must be taken repeatedly with allowance for hogging and sagging, and should be agreed by ship and shore.
✗
Question 54. What rowing equipment shall a liferaft carry?
Your Answer: (Not answered)
Correct Answer: D (Oars suitable for rowing)
💡 Oars shall be provided so the raft can be moved short distances.
✗
Question 55. What are the core documents of the safety management system required by SOLAS Chapter IX?
Your Answer: (Not answered)
Correct Answer: A (A safety management manual together with supporting procedures covering the elements of the system)
💡 SOLAS IX and the ISM Code require a safety management manual with supporting procedures covering the elements of the Code. A policy statement or a single plan does not constitute a complete system.
✗
Question 56. What should be done if dangerous goods packages are found damaged on board?
Your Answer: (Not answered)
Correct Answer: B (Take the measures in the EmS Guide, segregate the damaged packages, protect personnel and assess whether carriage may continue)
💡 On discovering damaged packages of dangerous goods, the measures in the EmS Guide should be taken: segregating the damaged packages, protecting personnel and ventilating, collecting the spillage and notifying the port and the company where necessary, assessing whether carriage may continue or the goods must be discharged. Discarding them at random or ignoring the matter is not acceptable.
✗
Question 57. On what is the effectiveness of the system judged?
Your Answer: (Not answered)
Correct Answer: D (The achievement of objectives, the trend in non-conformities, changes in accidents and near misses and the crew's grasp of the system)
💡 The effectiveness of the system should be judged on the achievement of safety and pollution prevention objectives, the number and trend of non-conformities, the occurrence and nature of accidents and near misses and the crew's grasp of the system and their duties, together with the quality of internal audits and management reviews, not merely on certificates or on passing an audit.
✗
Question 58. What condition regarding the suction of the emergency fire pump does SOLAS address?
Your Answer: (Not answered)
Correct Answer: D (It must be capable of drawing water under all operating draughts and trims of the ship)
💡 SOLAS requires the emergency fire pump suction to be arranged so that water can be drawn under all operating draughts and trims. Otherwise it may fail in a particular condition, a common ground for detention.
✗
Question 59. What fire division requirement applies to cargo spaces carrying dangerous goods?
Your Answer: (Not answered)
Correct Answer: B (The prescribed fire division rating, preventing spread of fire to adjacent spaces)
💡 SOLAS requires spaces carrying dangerous goods to be separated from adjacent spaces by class A divisions of the appropriate rating according to position, preventing a dangerous goods fire from spreading rapidly into the machinery space or accommodation.
✗
Question 60. What do SOLAS and the related conventions address regarding sewage treatment systems?
Your Answer: (Not answered)
Correct Answer: D (The plant must operate and discharge in accordance with the requirements, with attention to the risk of harmful gas)
💡 A sewage treatment plant must be operated and discharge in accordance with MARPOL, and attention paid to the harmful gases which may be produced in the process. The relevant spaces should be ventilated, entry restricted and testing carried out as prescribed to prevent poisoning.
✗
Question 61. Which of the following must be included in a distress alert sent by DSC?
Your Answer: (Not answered)
Correct Answer: C (Ship's identification and her position at the time)
💡 A DSC distress alert carries the ship's identity, position, nature of distress and the time of the alert.
✗
Question 62. Who approves the Ship Security Plan?
Your Answer: (Not answered)
Correct Answer: C (The Administration or its recognized security organization)
💡 ISPS Code Part A/9: the SSP must be approved by the Administration or its RSO.
✗
Question 63. What is required for bridge lighting at night?
Your Answer: (Not answered)
Correct Answer: A (Kept dim enough to preserve night vision while providing the lighting needed for instruments and chart work)
💡 Bridge lighting at night should be dim enough to preserve night vision while meeting the need for instrument, chart and equipment lighting, preferably red or dimmable. Excessive or white light destroys the watchkeeper's dark adaptation.
✗
Question 64. What does SOLAS address regarding fixed extinguishing systems for spaces carrying dangerous goods?
Your Answer: (Not answered)
Correct Answer: D (A system suited to the cargo, such as water spray, foam or inert gas, must be provided)
💡 SOLAS requires spaces carrying dangerous goods to have a fixed extinguishing system appropriate to the cargo. Some cargoes react with water or liberate toxic gas, so using water could make the situation worse.
✗
Question 65. What is required regarding medication affecting the ability to keep watch?
Your Answer: (Not answered)
Correct Answer: A (Crew taking medication that may impair judgement or reaction must not keep watch, with the company managing the risk)
💡 Medication that may cause drowsiness, reduced attention or slow reactions, such as some cold remedies, sedatives and antihistamines, impairs the ability to keep watch. Crew should report it and avoid standing watch or be relieved, and the company should have management requirements and a means for seafarers to declare their condition.
✗
Question 66. When should a renewal survey of a statutory certificate normally be completed?
Your Answer: (Not answered)
Correct Answer: A (Within a window of three months before or after the expiry date of the existing certificate)
💡 Under SOLAS I/14 and the harmonised survey system a renewal survey should be completed within a window of three months before or after the expiry date of the existing certificate, a new certificate being issued on satisfactory completion, with account taken of the harmonisation period. Failure leaves the certificate invalid and affects the ship's operation and insurance.
✗
Question 67. What is the principle for the number of thermal protective aids to be provided in survival craft?
Your Answer: (Not answered)
Correct Answer: D (Ten per cent of the number of persons the craft is permitted to accommodate, with additional requirements in certain cases)
💡 Under SOLAS III/22 survival craft should be provided with thermal protective aids, generally not less than ten per cent of the number of persons the craft is permitted to accommodate, to help prevent hypothermia of survivors. The provision also takes account of the temperature of the trading area.
✗
Question 68. What steering gear checks should be made before navigating in confined waters?
Your Answer: (Not answered)
Correct Answer: C (Check the steering gear alarms, test rudder movement and the rudder angle indicator and confirm the power and control systems are in order)
💡 Before navigating in confined waters such as a narrow channel or when berthing, the steering gear should be tested, the rudder angle indicator checked and the alarms and the power and control systems verified. A sudden steering failure in confined waters has serious consequences.
✗
Question 69. What is the safety significance of spare parts management?
Your Answer: (Not answered)
Correct Answer: D (Essential parts must be carried for critical equipment so that failures can be repaired promptly without affecting safety)
💡 Carrying spares for critical safety equipment, such as parts for fire pumps, wearing components of the emergency generator and steering gear and items of life-saving equipment, enables failures to be repaired promptly, avoiding the ship remaining in a deficient state for a long time while spares are awaited, which would affect her safety.
✗
Question 70. What language does SOLAS require for life-saving appliance markings?
Your Answer: (Not answered)
Correct Answer: C (The working language of the ship or English, with operating illustrations)
💡 SOLAS requires markings and instructions on life-saving appliances to be in the working language of the ship or in English, with illustrations, so that seafarers of different nationalities can understand them.
✗
Question 71. The ship shall carry for dangerous goods:
Your Answer: (Not answered)
Correct Answer: A (a list or manifest giving the name, class and location of the goods)
💡 SOLAS VII/5 requires a special list or manifest giving the name, class and location of the dangerous goods.
✗
Question 72. A PSCO found a lifeboat without a sea anchor. What is its function?
Your Answer: (Not answered)
Correct Answer: A (To reduce drift and keep the boat's head to wind and sea)
💡 The sea anchor controls drift and attitude in a seaway, keeping the boat's head to wind and reducing the risk of capsize. It is a key item for survival after abandonment, and its absence is a deficiency.
✗
Question 73. What does SOLAS address regarding the arrangement of fuel oil tanks?
Your Answer: (Not answered)
Correct Answer: C (They must be arranged to avoid proximity to or being above high temperature areas, reducing the risk of leaking oil contacting a source of heat)
💡 SOLAS requires fuel oil tanks to be arranged away from high temperature areas or from being above them, reducing the risk of leaking oil contacting hot surfaces or falling into hot zones of the machinery space, preventing fire.
✗
Question 74. What key information shall the shipper provide?
Your Answer: (Not answered)
Correct Answer: B (Cargo characteristics and the information needed for safe handling)
💡 Cargo characteristics and the information needed for safe carriage.
✗
Question 75. What is the relationship between the emergency switchboard and the main switchboard under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (The emergency switchboard is supplied from the emergency source, normally the emergency generator or battery, with appropriate interconnection to the main switchboard)
💡 SOLAS requires the emergency switchboard to be supplied from the emergency source, the emergency generator or battery, with appropriate interconnection to the main switchboard for normal conditions, while remaining independently supplied if the main source fails.
✗
Question 76. What action do SOLAS and STCW require if the main engine fails while under way?
Your Answer: (Not answered)
Correct Answer: A (Notify the bridge immediately, display the appropriate lights, shapes or sound signals and take action such as anchoring or other avoidance measures)
💡 Engine failure deprives the ship of manoeuvrability. The bridge must be informed at once, the lights, shapes or signals for a vessel not under command displayed, and measures such as anchoring taken to avoid collision, with the authorities informed.
✗
Question 77. Before proceeding to sea, the ship shall be:
Your Answer: (Not answered)
Correct Answer: A (ensured to be in all respects seaworthy, including adequate stability and trim)
💡 SOLAS V/34: before proceeding to sea the ship shall be ensured to be in all respects seaworthy, including adequate stability and trim.
✗
Question 78. Surveys shall be carried out by:
Your Answer: (Not answered)
Correct Answer: D (officers of the Administration or recognised organisations acting on its behalf)
💡 SOLAS I/5 requires surveys by officers of the Administration or recognised organisations on its behalf.
✗
Question 79. Which Convention governs the ship's handling of ballast water?
Your Answer: (Not answered)
Correct Answer: B (The Ballast Water Management Convention)
💡 Ballast water is to be managed under the Ballast Water Management Convention.
✗
Question 80. What is the main purpose of establishing restricted areas under the ship security plan?
Your Answer: (Not answered)
Correct Answer: C (To prevent unauthorised access and the introduction of weapons or dangerous articles)
💡 ISPS Code Part A/10 requires restricted areas to be identified and controlled in order to prevent unauthorised access and the introduction of weapons or dangerous articles on board. Convenience of operations is not the purpose.
✗
Question 81. What do COLREG and SOLAS require for overtaking in a narrow channel?
Your Answer: (Not answered)
Correct Answer: D (The overtaking vessel must obtain the agreement of the vessel being overtaken and keep a sufficient distance)
💡 COLREG Rule 9 requires a vessel intending to overtake in a narrow channel to obtain the agreement of the vessel to be overtaken, normally by VHF or sound signal, and to pass at a sufficient distance. Overtaking without agreement risks collision.
✗
Question 82. What does sea area A4 cover?
Your Answer: (Not answered)
Correct Answer: A (The area outside sea areas A1, A2 and A3, principally polar waters with no satellite coverage)
💡 Sea area A4 means the area outside A1, A2 and A3, principally polar waters beyond Inmarsat coverage. It is not a collective term for all sea areas.
✗
Question 83. Under what conditions shall the windlass reliably hold the anchor?
Your Answer: (Not answered)
Correct Answer: B (Under the specified weather conditions)
💡 It shall be capable of holding the anchor under the specified conditions.
✗
Question 84. Cargo ships of 1 000 GT and above shall be provided with at least how many independently driven fire pumps?
Your Answer: (Not answered)
Correct Answer: D (2)
💡 SOLAS II-2/10 requires at least two independently driven fire pumps for cargo ships of 1 000 GT and above.
✗
Question 85. What does SOLAS address regarding fire doors in an enclosed escape route?
Your Answer: (Not answered)
Correct Answer: C (Self-closing fire doors must be fitted, maintaining the fire integrity of the route)
💡 SOLAS requires self-closing fire doors in an enclosed escape route, allowing normal passage and closing automatically in a fire to preserve the fire integrity of the route. Ordinary or removed doors destroy that protection.
✗
Question 86. A PSC inspection found hydrant outlets in the machinery space that did not match the ship's hoses. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: A (All hydrant outlets and hose couplings must be interchangeable, with a uniform coupling standard)
💡 SOLAS requires hydrants, hoses and couplings to fit one another on a uniform standard, otherwise they cannot be assembled in a fire. A mixture of standards is a common ground for detention.
✗
Question 87. The second officer drafts the quarterly drill plan: "muster monthly, brief on the equipment, everyone to the station, no boat actually lowered." Measured against the SOLAS chapter III drill frequencies, what is missing?
Your Answer: (Not answered)
Correct Answer: A (every lifeboat should be launched with its assigned crew at intervals not exceeding 3 months and manoeuvred with them, and launched with at least two crew at intervals not exceeding 6 months)
💡 The frequencies are easy to mix up: launching with the assigned crew and manoeuvring at intervals within 3 months, launching with two or more crew within 6 months. The monthly abandon-ship and fire drill is a separate layer and neither substitutes for the other, and an annual survey of the appliances says nothing about the crew's ability to get the boat down.
✗
Question 88. What is the basic principle for selecting portable extinguishers for a machinery space?
Your Answer: (Not answered)
Correct Answer: B (the class of fire likely in the space deciding the choice, oil and electrical fires requiring a suitable agent, the number and siting as prescribed)
💡 In a machinery space the likely fires are oil and electrical. Water will spread a burning oil fire and carries the shock risk on live equipment, so it belongs to solid combustible fires; here foam, powder or carbon dioxide suits the class, with the capacity, number and siting the rules call for along passages and in spaces, placed where a hand can reach it and not blocked by gear or cargo. Carbon dioxide released in quantity in a small closed space drives the oxygen down, which has to be thought of as the party withdraws. Counting only the extinguishers and their service dates, without regard to whether the type suits the space, is a deficiency waiting to be written up and a mistake waiting to be made at the fire itself.
✗
Question 89. Rescue boat launching appliances shall be capable of launching and recovering the rescue boat when the ship is making headway at up to:
Your Answer: (Not answered)
Correct Answer: A (5 knots)
💡 SOLAS III/16 requires the rescue boat launching appliance to operate at ship's headway of up to 5 knots.
✗
Question 90. Which back-up arrangements are accepted when ECDIS is used to satisfy the chart carriage requirement?
Your Answer: (Not answered)
Correct Answer: C (A full folio of up-to-date paper charts or a second ECDIS with independent power supply)
💡 SOLAS V/19 requires adequate back-up for ECDIS, normally a full folio of corrected paper charts or a second ECDIS with independent power supply. Internal files or a CD do not constitute adequate back-up.
✗
Question 91. What does SOLAS address regarding the function of the double bottom in the event of damage?
Your Answer: (Not answered)
Correct Answer: B (The inner space limits flooding and protects the inner bottom structure when the bottom is damaged)
💡 One of the principal reasons SOLAS requires a double bottom is that when the bottom is damaged by grounding or stranding, the double bottom space limits the extent of flooding and protects the inner bottom structure, reducing the volume of water admitted and improving survivability.
✗
Question 92. What does SOLAS address regarding sounding and observation arrangements for fuel oil tanks?
Your Answer: (Not answered)
Correct Answer: C (Safe and reliable measuring arrangements, preventing oil from overflowing or spraying out)
💡 SOLAS requires fuel oil tank measuring arrangements to be safe and reliable, such as self-closing sounding pipes or closed level gauges, preventing oil from overflowing or spraying onto hot surfaces during measurement and causing fire.
✗
Question 93. The bridge arrangement shall ensure that:
Your Answer: (Not answered)
Correct Answer: D (The look-out is not obstructed from any direction)
💡 SOLAS V/22: the bridge must permit an unobstructed view all round from the conning position.
✗
Question 94. For free-fall lifeboats, drills shall include:
Your Answer: (Not answered)
Correct Answer: D (a free-fall launch at the required interval or an equivalent approved method)
💡 SOLAS III/19 requires free-fall lifeboats to be free-fall launched at the prescribed interval or by an approved equivalent method.
✗
Question 95. What does SOLAS address regarding drainage of ro-ro spaces?
Your Answer: (Not answered)
Correct Answer: A (Effective drainage removing firefighting water and leaked oil promptly)
💡 SOLAS requires ro-ro spaces to have effective drainage and storage arrangements able to remove firefighting water and leaked oil promptly, preventing free surface from affecting stability and reducing the risk of oil spreading the fire.
✗
Question 96. For SOLAS purposes, a passenger ship is one which carries more than how many passengers?
Your Answer: (Not answered)
Correct Answer: A (More than 12)
💡 SOLAS I/2: a passenger ship carries more than 12 passengers; children under one year are not counted.
✗
Question 97. In sea area A1, on what channel must a ship maintain watch under GMDSS?
Your Answer: (Not answered)
Correct Answer: A (DSC watch on VHF channel 70, together with any required radiotelephony watch)
💡 SOLAS IV requires a DSC watch on VHF channel 70 in sea area A1, together with the prescribed watch on the associated radiotelephony channel. A single voice channel watch is not sufficient.
✗
Question 98. What should be done first when a fire breaks out in accommodation spaces?
Your Answer: (Not answered)
Correct Answer: C (Raise the alarm, organise evacuation and shut off ventilation to the area and, as required, the power)
💡 A fire in accommodation should first trigger the alarm, with evacuation and firefighting organised under the muster list, ventilation shut off as necessary to limit smoke spread and power controlled. Breaking in hastily admits air that feeds the fire and endangers personnel.
✗
Question 99. Which channel is used for VHF DSC distress alerting?
Your Answer: (Not answered)
Correct Answer: B (Channel 70)
💡 VHF DSC distress and calling use channel 70, which is not used for speech. Channel 16 is for radiotelephony distress and safety traffic.
✗
Question 100. A ship grounded and the investigation found no adequate scale charts of the area on board. What does SOLAS require regarding charts?
Your Answer: (Not answered)
Correct Answer: C (Charts or ENCs of adequate scale covering the intended voyage, kept corrected to the latest information)
💡 SOLAS V/19 requires charts or ENCs of adequate scale covering the whole intended voyage, corrected to the latest information. A general chart or overview display is not sufficient for safe navigation, and the absence of adequate charts is a common cause of grounding.