Question 1. In the subdivision of a passenger ship, what does the "subdivision load line" mean?
Your Answer: (Not answered)
Correct Answer: D (An assumed load line used to determine subdivision requirements, not the ship's actual service load line)
💡 The subdivision load line is an assumed load line used in determining subdivision requirements such as bulkhead positions and the subdivision index. It is a different concept from the summer or tropical load lines actually used in service.
✗
Question 2. What preparation does SOLAS and good seamanship require before heavy weather?
Your Answer: (Not answered)
Correct Answer: C (Check and secure deck and hold cargo, close watertight openings and adjust course and speed to reduce impact)
💡 Before heavy weather, cargo securing should be checked, watertight openings closed and course and speed adjusted to reduce hull stress, with the ship's condition monitored, limiting the risk of structural damage and cargo shift.
✗
Question 3. What time window is permitted for an annual survey under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (Within three months before or after the anniversary date, with the next due date counted from the anniversary)
💡 SOLAS provides for the annual survey to be carried out within a window of three months before or after the anniversary date, with the next due date counted from the anniversary. The interval must not be extended at will.
✗
Question 4. What assessment and improvement follows emergency drills?
Your Answer: (Not answered)
Correct Answer: A (Analyse the problems found, assess the effectiveness of the procedures and revise them, forming a closed loop)
💡 The ISM Code and good practice require drills to be assessed: the problems found, such as slow response, unclear duties or unavailable equipment, analysed, the effectiveness of the existing procedures and training evaluated and revisions made, so that drills genuinely drive improvement of the system in a closed loop.
✗
Question 5. What do SOLAS and good practice address regarding the hydraulic steering gear?
Your Answer: (Not answered)
Correct Answer: A (Oil level and pressure monitoring with alarms, preventing loss of steering through low oil or loss of pressure)
💡 The hydraulic steering gear should have oil level and pressure monitoring with alarms, detecting oil loss or loss of pressure in good time, since steering failure directly endangers the safe manoeuvring of the ship.
✗
Question 6. What does the weekly inspection of a lifeboat require regarding the engine?
Your Answer: (Not answered)
Correct Answer: A (Start and run it for the prescribed period, checking starting, running and cooling)
💡 SOLAS requires the boat engine to be started and run for the prescribed period, normally not less than three minutes, during the weekly inspection, checking that it starts readily, runs smoothly and discharges cooling water properly. An appearance or level check alone would not reveal an actual fault.
✗
Question 7. What is the basic requirement of SOLAS for protection against electric shock?
Your Answer: (Not answered)
Correct Answer: A (Live parts must be protected, and safety voltage or isolation used in hazardous locations)
💡 SOLAS requires exposed live parts to be protected and safety voltage or isolation and residual current protection to be used in damp or metal-enclosed locations, reducing the risk of electric shock.
✗
Question 8. The steering gear takes 35 seconds to move the rudder from 35 degrees one side to 30 degrees the other. What is the finding?
Your Answer: (Not answered)
Correct Answer: B (It exceeds the prescribed 28 seconds and does not comply; the steering gear performance must be investigated)
💡 SOLAS II-1/29 requires the main steering gear, at maximum service speed and deepest seagoing draught, to complete the movement from 35 degrees one side to 30 degrees the other within 28 seconds. Thirty five seconds exceeds the limit and indicates a problem with the power or control capability of the steering gear.
✗
Question 9. Life-saving appliances are kept on a planned maintenance schedule. How are the weekly and monthly checks divided?
Your Answer: (Not answered)
Correct Answer: C (weekly testing of the general alarm and of lighting at muster and embarkation stations, monthly examination of all appliances with their equipment confirmed complete and recorded)
💡 The Convention separates the two by object: weekly, the general emergency alarm system and the emergency lighting at muster and embarkation stations are tested; monthly, all life-saving appliances are examined, boats, rafts, their equipment, launching arrangements and engines being confirmed ready for immediate use, with defects logged. Shrinking the monthly check to one pass before the annual survey, or leaving rafts out of the ship's duties, is how equipment turns up missing when it is wanted.
✗
Question 10. What is the relationship between a lifeboat's permitted complement and the overload test?
Your Answer: (Not answered)
Correct Answer: B (The boat should be used within its permitted complement, with an overload test carried out as required to verify strength and safety)
💡 A lifeboat's permitted complement is the specified safe carrying capacity and must not be exceeded in use. Under the relevant requirements a lifeboat may undergo an overload test, such as at one point one times the permitted complement or a specified load, to verify the strength and safety margin of the davits and the boat. Overloading endangers the safety of launching.
✗
Question 11. What does SOLAS V and STCW require regarding watchkeeping when a ship is at anchor?
Your Answer: (Not answered)
Correct Answer: C (A proper anchor watch must be maintained, keeping continuous watch on the ship's position, weather and nearby traffic)
💡 Anchoring does not end watchkeeping duties. SOLAS and STCW require a proper anchor watch, monitoring position, weather changes and the risk of dragging, and taking timely action.
✗
Question 12. In addition to ventilation, what shall be fitted in paint lockers and flammable liquid stores?
Your Answer: (Not answered)
Correct Answer: D (A fixed fire-extinguishing system)
💡 SOLAS II-2/10.6.3: paint lockers and flammable liquid stores shall have a fixed fire-extinguishing arrangement.
✗
Question 13. For how long shall the reserve source of energy for radio installations supply?
Your Answer: (Not answered)
Correct Answer: B (6 hours)
💡 Six hours on ships without an emergency generator.
✗
Question 14. What should the ventilation measures meet before entering an enclosed space?
Your Answer: (Not answered)
Correct Answer: A (Adequate ventilation should be provided and the atmosphere tested as satisfactory before entry, with continuous ventilation and an attendant during the work)
💡 Before entering an enclosed space adequate ventilation should be provided and the atmosphere tested for oxygen, flammable gas and toxic gas and confirmed satisfactory, and during entry ventilation should be continuous, an attendant stationed at the entrance and communication maintained. Entry without ventilation, testing or an attendant is prohibited.
✗
Question 15. What do SOLAS and the IMDG Code require for marking and labelling of dangerous goods packages?
Your Answer: (Not answered)
Correct Answer: D (The proper shipping name, UN number and the relevant hazard class label)
💡 SOLAS VII and the IMDG Code require dangerous goods packages to show the proper shipping name, the UN number and the relevant hazard class label, including the marine pollutant mark, so that the crew can identify the hazard and act accordingly.
✗
Question 16. What emergency supplies are required in polar waters?
Your Answer: (Not answered)
Correct Answer: D (Sufficient warm clothing, emergency food and water, heating means and emergency lighting)
💡 The Polar Code requires emergency supplies suited to the polar environment: ample warm clothing and thermal protection, emergency food and water, means of heating such as a spare heater, emergency lighting and communication equipment, in view of the long search and rescue response times.
✗
Question 17. What measures are required to manage fatigue of officers?
Your Answer: (Not answered)
Correct Answer: B (Arrange watches and rest properly, avoid prolonged continuous duty and ensure the prescribed rest hours with records kept)
💡 STCW requires fatigue to be managed by proper arrangement of watch rotations and rest periods, avoiding prolonged continuous duty and ensuring the prescribed rest hours with records kept. Fatigue seriously affects judgement and reaction and is a major cause of navigational accidents.
✗
Question 18. Lifeboat and liferaft launching appliances shall be inspected and tested at intervals not exceeding:
Your Answer: (Not answered)
Correct Answer: B (monthly)
💡 SOLAS III/20 requires launching appliances to be inspected weekly and tested monthly.
✗
Question 19. What are the main items checked when an inflatable liferaft is serviced?
Your Answer: (Not answered)
Correct Answer: B (Tightness of the raft, the inflation system, the equipment, the weak link and the hydrostatic release unit)
💡 Servicing an inflatable liferaft covers a tightness test, the inflation system including cylinder pressure and valves, the completeness and expiry of the equipment and the condition of the weak link and hydrostatic release unit. Failure of any of these would affect use after abandonment.
✗
Question 20. Regarding main and emergency sources of electrical power, which statement is correct?
Your Answer: (Not answered)
Correct Answer: A (the emergency source comes into operation automatically upon failure of the main source)
💡 SOLAS II-1 requires the emergency source to come into operation automatically upon failure of the main source, being independent from it.
✗
Question 21. What should an equipment failure record contain?
Your Answer: (Not answered)
Correct Answer: A (The time, symptoms, part affected, cause analysis, action taken and restoration)
💡 An equipment failure record should contain the time, the symptoms and the part affected, an analysis of the cause, the emergency and repair action taken, the return to service and whether safety of navigation was affected or reporting was needed. A complete record supports later repair, analysis and survey.
✗
Question 22. What are the handling requirements when encountering heavy swell and seas?
Your Answer: (Not answered)
Correct Answer: A (Adjust course and speed so that the hull meets the seas at a suitable angle, avoiding a beam sea and direct head seas which cause damage)
💡 In heavy seas and swell the course and speed should be adjusted so the hull meets the seas at a suitable angle, normally obliquely, avoiding a beam sea which causes heavy rolling and cargo shift and direct head seas which cause violent pitching and slamming that damages the hull.
✗
Question 23. What insulation monitoring is required for the electrical system?
Your Answer: (Not answered)
Correct Answer: B (Insulation monitoring means such as a switchboard insulation resistance meter or monitor, detecting a fall promptly)
💡 SOLAS requires means of insulation monitoring, such as an insulation resistance meter on the main switchboard or an insulation monitor, giving continuous or periodic indication of the insulation to earth and an alarm when it falls, so that leakage and faults are found in time.
✗
Question 24. What are the key points in using a portable extinguisher?
Your Answer: (Not answered)
Correct Answer: D (Pull the pin, aim the nozzle at the base of the fire and sweep while pressing the lever)
💡 Using a portable extinguisher involves pulling the pin, holding the nozzle and aiming at the base of the fire, that is the burning surface, then sweeping while pressing the lever. Aiming at the top of the flames is ineffective, and the position should allow a line of retreat.
✗
Question 25. What are the principal risks the officer of the watch should consider when navigating in coastal waters?
Your Answer: (Not answered)
Correct Answer: C (High traffic density, many fishing and small craft, crossing routes and shoal water, and fishing gear or aquaculture installations)
💡 Coastal waters have dense traffic, frequent fishing and small craft, crossing routes, fishing gear and aquaculture installations, while shoal water affects under-keel clearance. The officer must enhance the look-out, manoeuvre prudently and keep a safe speed.
✗
Question 26. Which document must be readily available on board after container loading?
Your Answer: (Not answered)
Correct Answer: B (Container Packing Certificate)
💡 The Container Packing Certificate, signed by the person responsible, evidences correct stowage.
✗
Question 27. What familiarisation training is required for newly joined crew?
Your Answer: (Not answered)
Correct Answer: A (Completed before taking up duties, covering duties, the location and operation of equipment and emergency duties and procedures)
💡 The ISM Code and STCW require newly joined crew to complete familiarisation training before taking up their duties, covering their responsibilities on board, the location and operation of relevant equipment and emergency duties and procedures and safety and pollution prevention requirements, with records kept. Training after taking up duties is not acceptable.
✗
Question 28. What is the requirement for rescue boats on cargo ships?
Your Answer: (Not answered)
Correct Answer: D (At least one rescue boat)
💡 At least one rescue boat shall be provided.
✗
Question 29. What is required for monitoring stability during loading and unloading?
Your Answer: (Not answered)
Correct Answer: C (Monitor stability and strength at each stage against the loading plan, preventing excessive hogging or sagging or insufficient initial stability)
💡 SOLAS requires stability and hull strength to be monitored at each stage against the loading plan, preventing excessive hogging or sagging and insufficient initial stability. Calculating only afterwards cannot prevent structural damage during cargo work.
✗
Question 30. What does SOLAS and the Polar Code require regarding manning and training for polar waters?
Your Answer: (Not answered)
Correct Answer: A (The master and officers in charge of a navigational watch must have completed appropriate polar waters training and gained the required experience)
💡 SOLAS XIV and STCW require the master and officers in charge of a navigational watch of a ship in polar waters to have completed polar waters training appropriate to the ship's category and to have the prescribed seagoing experience, ensuring the ability to operate in polar conditions.
✗
Question 31. The voyage plan shall include:
Your Answer: (Not answered)
Correct Answer: A (a berth-to-berth plan giving due consideration to navigational hazards including safe speed)
💡 SOLAS V/34: the voyage plan covers the whole passage from berth to berth, giving due consideration to navigational hazards and safe speed.
✗
Question 32. Which of the following is NOT required navigation equipment under SOLAS V/19?
Your Answer: (Not answered)
Correct Answer: A (facsimile machine)
💡 SOLAS V/19: a facsimile machine is not among the navigation equipment required by SOLAS V/19.
✗
Question 33. To which ship types does the Enhanced Programme of Inspections apply?
Your Answer: (Not answered)
Correct Answer: C (Oil tankers and bulk carriers)
💡 SOLAS XI-1/2 applies the enhanced programme of inspections to oil tankers and bulk carriers, imposing stricter survey requirements on these higher-risk ship types. It does not apply to all ships.
✗
Question 34. What does SOLAS address regarding the quantity of extinguishing medium in a fixed system?
Your Answer: (Not answered)
Correct Answer: B (Calculated from the volume of the protected space with the prescribed margin)
💡 SOLAS requires the quantity of extinguishing medium to be calculated from the net volume of the protected space and to meet the prescribed minimum concentration and margin, ensuring an effective concentration after release.
✗
Question 35. If a vessel cannot give effective assistance to a ship in distress, it shall:
Your Answer: (Not answered)
Correct Answer: C (Record it and report the situation to the appropriate authority)
💡 Record the matter and report to the appropriate authority.
✗
Question 36. An inert gas system on a tanker was verified during a PSC inspection. What does SOLAS require for the oxygen content in cargo tanks?
Your Answer: (Not answered)
Correct Answer: A (It must be kept at not more than 8 per cent by volume, in accordance with the prescribed limit)
💡 SOLAS and the IBC and IGC Codes require the oxygen content of inerted cargo tanks to be kept at not more than 8 per cent by volume, so that hydrocarbon vapour cannot burn. Exceeding the limit means inerting has failed, a serious deficiency.
✗
Question 37. Each ship shall carry how many lifejackets for every person on board?
Your Answer: (Not answered)
Correct Answer: D (one per person)
💡 SOLAS III/7 requires one lifejacket for every person on board, with additional child lifejackets as required.
✗
Question 38. What does SOLAS require regarding manoeuvring information?
Your Answer: (Not answered)
Correct Answer: C (Manoeuvring information such as turning circles and stopping distances must be available on board for the master's use)
💡 SOLAS V/19.2.8 requires manoeuvring information such as turning circles, stopping distances and track reach to be on board for the master's use in narrow channels and during berthing. Shore-side retention does not comply.
✗
Question 39. A PSC inspection found the AIS switched off throughout the voyage. On what basis is this a deficiency?
Your Answer: (Not answered)
Correct Answer: C (AIS must remain in operation and may be switched off only where the master considers this necessary for safety or security)
💡 SOLAS V/19.2.10 requires AIS to remain in operation. It may be switched off only where the master believes its operation might compromise safety or security, with the reason and period recorded in the log. Leaving it off without justification is a deficiency.
✗
Question 40. What does SOLAS require regarding local and remote operation of watertight doors?
Your Answer: (Not answered)
Correct Answer: B (They must be operable locally from both sides of the door and closable remotely from the bridge)
💡 SOLAS requires watertight doors to be operable locally from both sides of the door and closable by remote control from the bridge. Both means must be available; one alone does not comply.
✗
Question 41. Where should the fire control plan be stowed on board?
Your Answer: (Not answered)
Correct Answer: B (In a conspicuously marked weathertight enclosure outside the deckhouse, with a further copy on the bridge or equivalent position)
💡 SOLAS II-2/15 requires the fire control plan to be permanently stowed in a conspicuously marked weathertight enclosure outside the deckhouse, with another copy on the bridge or equivalent, for use by shore firefighters.
✗
Question 42. What does SOLAS require for emergency communication between the bridge and the machinery space?
Your Answer: (Not answered)
Correct Answer: A (Means independent of the main communication system, such as the telegraph or an independent telephone)
💡 SOLAS requires an independent means of emergency communication between the bridge and machinery space, so that manoeuvring orders can still be passed if the main system fails. A hand-held radio is not an acceptable compliant means.
✗
Question 43. The function of flame arresters in a tanker cargo tank venting system is to:
Your Answer: (Not answered)
Correct Answer: C (prevent external flame from entering the cargo tanks)
💡 SOLAS II-2/4 requires flame arresters to prevent external flame from passing through vent pipes into cargo tanks.
✗
Question 44. Which equipment shall be provided to maintain an effective watch against collision with a towing operation in restricted visibility?
Your Answer: (Not answered)
Correct Answer: D (Radar and AIS)
💡 Towing operations present a large, dispersed target, so radar and AIS are required in addition to visual watch.
✗
Question 45. Portable fire extinguishers in machinery spaces shall be:
Your Answer: (Not answered)
Correct Answer: A (at least one near each hydrant and sufficient in total for the space)
💡 SOLAS II-2/10 requires at least one portable extinguisher near each hydrant, with sufficient total number.
✗
Question 46. What are common reasons for a finding of ISM system failure during a PSC inspection?
Your Answer: (Not answered)
Correct Answer: B (Repeated serious deficiencies of the same kind, records seriously inconsistent with the ship, or the crew unfamiliar with key operations or emergency duties)
💡 Findings of system failure commonly rest on the recurrence of serious deficiencies of the same kind, showing corrective action has been ineffective, records seriously inconsistent with the ship, such as falsified drill records, the crew unfamiliar with the equipment they operate or with their emergency duties, and critical equipment long out of repair, all showing that the system is not being implemented effectively.
✗
Question 47. Besides the number, what has to be managed about portable extinguishers?
Your Answer: (Not answered)
Correct Answer: B (placed where they are seen and reached at once, their agent marked on them, and tested at the intervals set)
💡 Beyond the count there are three things to hold. Where they stand: well distributed, plainly seen, not behind cargo or equipment, one near the entrances to a machinery space and about the accommodation, so the plate and the escape lighting let a man find one through smoke. What is in them: matched to the fire the space can give - water not being the thing for a liquid fire or a live circuit - with the agent stated on the set so nobody grabs the wrong one. And their condition: weighed, gauged and checked at the intervals fixed, sent away or scrapped when the date or the pressure says so, the check and its finding written down. The number is settled for the type of space and this ship's layout, not copied from another vessel, and the crew are trained to draw and use them under strain, knowing both the reach and the short time each will serve.
✗
Question 48. What do SOLAS and the Load Line Convention address regarding the height of coamings at openings in the freeboard deck?
Your Answer: (Not answered)
Correct Answer: A (Coamings must reach the prescribed height to prevent sea water entering spaces below)
💡 SOLAS and the Load Line Convention require openings in the freeboard deck leading to spaces below to have coamings of the prescribed height with effective closing appliances, preventing water shipped on deck from entering and affecting stability.
✗
Question 49. A rescue boat shall be provided with equipment including:
Your Answer: (Not answered)
Correct Answer: B (a complete set including oars, lifebuoy, first-aid kit and searchlight)
💡 SOLAS III/34 (LSA Code) requires a rescue boat to carry equipment including oars, lifebuoy, first-aid kit and searchlight.
✗
Question 50. A PSCO tested ventilation closing devices and found some seized. What does SOLAS address?
Your Answer: (Not answered)
Correct Answer: A (Closing devices of machinery space ventilators must close rapidly to cut off ventilation and air supply)
💡 SOLAS II-2 requires machinery space ventilator closing devices to close rapidly and remain effective, cutting off the air supply in a fire. Seized devices or a lack of regular testing are common deficiencies.
✗
Question 51. Segregation is required when dangerous goods are stowed on board. What is the fundamental purpose?
Your Answer: (Not answered)
Correct Answer: B (To prevent incompatible substances reacting dangerously on contact)
💡 Segregation under SOLAS VII/3 and the IMDG Code prevents incompatible substances from reacting if released, causing fire, explosion or toxic gas. It is not a tallying convenience.
✗
Question 52. In radiocommunication, what is the priority of distress communication?
Your Answer: (Not answered)
Correct Answer: B (It has the highest priority above all other communication, which must give way to it)
💡 Under the Radio Regulations and the GMDSS distress communication has the highest priority and all other communication must give way and keep silence while it is in progress. A ship receiving a distress alert or distress traffic must not use the distress frequencies for non-distress communication.
✗
Question 53. What preparation and checks are required before entering port?
Your Answer: (Not answered)
Correct Answer: D (Test the main engine and steering gear, check the telegraph, verify draught and under-keel clearance and confirm certificates and documents are in order)
💡 Before entering port the main engine and steering gear should be tested, the telegraph checked, the windlass and thrusters where fitted examined, the draught and under-keel clearance verified and the nautical publications corrected and certificates ready, so that the ship is fully under control in confined waters.
✗
Question 54. Which is the MF digital selective calling distress frequency?
Your Answer: (Not answered)
Correct Answer: A (2187.5 kHz)
💡 2187.5 kHz is the MF DSC distress frequency; 2182 kHz is the MF radiotelephony distress frequency.
✗
Question 55. A shipment of dangerous goods is offered without a proper shipping name. What should the master do?
Your Answer: (Not answered)
Correct Answer: D (Require the proper shipping name, UN number and other information, refusing to load if it is incomplete)
💡 SOLAS VII and the IMDG Code require dangerous goods to be declared under the proper shipping name with the UN number, class and packing group. An incomplete declaration or a general description such as chemicals would leave the crew unable to identify the hazards. The master should require full information, or refuse to load.
✗
Question 56. The ISPS Code applies to:
Your Answer: (Not answered)
Correct Answer: A (passenger ships and cargo ships of 500 GT and above engaged on international voyages)
💡 SOLAS XI-2/3: the ISPS Code applies to passenger ships and cargo ships of 500 GT and above engaged on international voyages.
✗
Question 57. A Safety Management Certificate (SMC) shall be issued for a period not exceeding:
Your Answer: (Not answered)
Correct Answer: C (5 years)
💡 SOLAS IX/4: a Safety Management Certificate shall be issued for a period not exceeding 5 years.
✗
Question 58. Who issues the Safety Management Certificate?
Your Answer: (Not answered)
Correct Answer: B (The Administration or its recognized organization)
💡 The Administration or its recognized organization.
✗
Question 59. A fire in the machinery space has ruptured the fire main within that space. What is the purpose of the isolation valves fitted on the fire main?
Your Answer: (Not answered)
Correct Answer: A (To isolate the damaged section so the remainder of the main stays charged)
💡 SOLAS II-2/10.2 requires isolation valves so that a damaged section can be cut off while the rest of the fire main remains supplied with water.
✗
Question 60. The separation between cargo tanks and machinery spaces on a tanker shall be:
Your Answer: (Not answered)
Correct Answer: A (A class division)
💡 SOLAS II-2/9: the separation between cargo tanks and machinery spaces on a tanker shall be an A class division.
✗
Question 61. On what basis must first aid be given in a dangerous goods incident involving poisoning or burns?
Your Answer: (Not answered)
Correct Answer: D (MFAG, the Medical First Aid Guide for use in accidents involving dangerous goods)
💡 SOLAS VII requires MFAG to be carried on board, with first aid given according to the relevant card, such as decontamination, oxygen and artificial respiration, gaining time for subsequent medical treatment.
✗
Question 62. Among the information entered into AIS, which is static?
Your Answer: (Not answered)
Correct Answer: B (The IMO number, call sign and ship's name, being fixed particulars of the ship)
💡 AIS static information includes the IMO number, call sign, name and type of ship, entered at installation and rarely changed. Position, course and speed are dynamic; destination and ETA are voyage related.
✗
Question 63. What is one of the main functions of an Inmarsat-C ship earth station in GMDSS?
Your Answer: (Not answered)
Correct Answer: B (Transmitting and receiving distress alerts and enhanced group call maritime safety information)
💡 Inmarsat-C can transmit distress alerts, receive EGC SafetyNET information and provide two-way messaging, making it an important means of meeting GMDSS requirements in sea area A3.
✗
Question 64. What does security level 2 signify?
Your Answer: (Not answered)
Correct Answer: B (A heightened risk of a security incident requiring additional protective measures)
💡 Under the ISPS Code level 1 is the minimum in normal circumstances, level 2 additional measures when risk is heightened, and level 3 specific measures when an incident is probable or imminent. The measures escalate by level.
✗
Question 65. A PSC inspection found a lifeboat equipment locker locked with the key not in the boat. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: A (Equipment of survival craft must be ready for immediate use and must not be locked away)
💡 SOLAS requires survival craft equipment to be ready for immediate use. Locking it away or storing it elsewhere means it cannot be reached promptly in an abandonment, contrary to the readiness requirement, and is a deficiency.
✗
Question 66. Which symbol denotes the degree of subdivision of a passenger ship?
Your Answer: (Not answered)
Correct Answer: D (R)
💡 A required subdivision index is applied to passenger ships.
✗
Question 67. What does the Polar Code address regarding safety equipment for ships in polar waters?
Your Answer: (Not answered)
Correct Answer: B (Equipment suited to the polar environment for life-saving, firefighting, ice protection and emergencies)
💡 The Polar Code requires equipment suited to the polar environment, such as thermally protective life-saving appliances, firefighting equipment suitable for low temperature, ice protection and de-icing arrangements and emergency communication and escape means. Ordinary water equipment is not sufficient.
✗
Question 68. The lifeboat drill records for three consecutive months are identical. What is the PSCO's concern?
Your Answer: (Not answered)
Correct Answer: B (It may indicate that drills were not actually carried out with different scenarios or that the records are not truthful, requiring verification of their genuineness)
💡 Identical drill records over successive months raise doubt about the genuineness and effectiveness of the drills, and the PSCO may check the crew's practical ability further. Scenarios should vary and address different risks, and the records should reflect what was actually done.
✗
Question 69. A watertight door open/closed indicator at the central control station shows the wrong state, a door actually open being indicated as closed. The finding is?
Your Answer: (Not answered)
Correct Answer: D (A wrong indication may mislead the bridge as to the subdivision state; a deficiency to be corrected)
💡 The open/closed indicator at the central control station is an important basis for judging the actual state of each watertight door and deciding on closing measures. A wrong indication misleads the bridge as to subdivision integrity and may delay closure in the event of flooding. It is a deficiency to be corrected.
✗
Question 70. What is the principal characteristic of class 3 dangerous goods?
Your Answer: (Not answered)
Correct Answer: C (Flammable liquids, whose vapour can be ignited at ambient temperature)
💡 Class 3 of the IMDG Code covers flammable liquids, being liquids which give off flammable vapour at or below their flashpoint. Explosives are class 1 and oxidising substances class 5.
✗
Question 71. What is required for stability calculation after loading is completed?
Your Answer: (Not answered)
Correct Answer: C (Calculate the stability for the departure and arrival conditions and confirm compliance with the stability information)
💡 SOLAS requires the stability for departure and arrival conditions to be calculated and confirmed against the stability information, checking parameters such as metacentric height and righting levers. Any exceedance requires adjustment.
✗
Question 72. What must a Declaration of Security contain?
Your Answer: (Not answered)
Correct Answer: B (The responsibilities, contacts and measures of each party at the security level applicable and the procedure if it changes)
💡 The ISPS Code requires a Declaration of Security to set out the responsibilities, points of contact and measures of the ship and the port facility at the applicable security level, together with the procedure if that level changes, making the security responsibilities during the interface clear.
✗
Question 73. The carriage of dangerous goods in packaged form shall follow:
Your Answer: (Not answered)
Correct Answer: B (the International Maritime Dangerous Goods (IMDG) Code)
💡 SOLAS VII/3: the carriage of dangerous goods in packaged form shall follow the IMDG Code.
✗
Question 74. What is the purpose of AIS?
Your Answer: (Not answered)
Correct Answer: B (Automatic broadcast and reception of ship identification and navigational information)
💡 To broadcast and receive ship identification and navigational information automatically.
✗
Question 75. What medical first aid guidance must a ship carrying dangerous goods carry?
Your Answer: (Not answered)
Correct Answer: C (MFAG, the Medical First Aid Guide for use in accidents involving dangerous goods)
💡 SOLAS requires MFAG for the treatment of poisoning and chemical injury, while the EmS Guide addresses fire and spill response. The two serve different purposes and neither replaces the other.
✗
Question 76. What is required when new piping is passed through a fire division during a conversion?
Your Answer: (Not answered)
Correct Answer: D (Execute the approved penetration sealing arrangement, updating the fire control plan and records)
💡 New penetrations of a fire division require the approved penetration sealing arrangement to be used, with approved seals of equivalent fire rating, while the fire control plan and records are updated and the work verified by the classification society. A plain hole or cement sealing destroys the fire integrity of the division.
✗
Question 77. Pipes passing through the collision bulkhead shall be fitted with:
Your Answer: (Not answered)
Correct Answer: C (a valve operable from above the bulkhead deck, with the valve chest inside the forepeak)
💡 SOLAS II-1/12 requires pipes through the collision bulkhead to be fitted with a valve operable from above the bulkhead deck.
✗
Question 78. What is required for backup power of the firefighting system?
Your Answer: (Not answered)
Correct Answer: C (The emergency fire pump must have a source of power independent of the main fire pumps, so water is available on a blackout or machinery space fire)
💡 SOLAS requires the emergency fire pump to be independently driven, such as by a dedicated diesel engine or an independent power supply, so that it can still supply water if a blackout or a fire in the machinery space puts the main fire pumps out of action. It is essential to the redundancy of the firefighting system.
✗
Question 79. Fire hoses shall be provided:
Your Answer: (Not answered)
Correct Answer: B (for each hydrant in sufficient number, including spare hoses)
💡 SOLAS II-2/10: fire hoses shall be provided for each hydrant in sufficient number, including spare hoses.
✗
Question 80. What additional safety is required when carrying timber deck cargo?
Your Answer: (Not answered)
Correct Answer: A (Enhanced securing, safe access and unobstructed visibility, with attention to deck load and stability)
💡 Timber deck cargo requires enhanced securing with the prescribed methods and attention to the weight gained by water absorption, safe access for the crew and an unobstructed view from the bridge, with deck loading and stability calculated including the effects of water absorption and ice accretion, in accordance with the timber deck cargo requirements of the Load Line Convention.
✗
Question 81. What must be handed over regarding radar and ECDIS at a watch handover?
Your Answer: (Not answered)
Correct Answer: B (The encountered situations, avoiding action taken and important information on the radar and ECDIS)
💡 At handover, the situations encountered during the watch, the avoiding action taken and important targets and warnings on the radar and ECDIS should be passed on, enabling the relieving officer to continue monitoring. Position and course alone may leave a critical risk unmentioned.
✗
Question 82. Water-tight doors shall be capable of being operated watertight:
Your Answer: (Not answered)
Correct Answer: D (At all times)
💡 Water-tight doors must be capable of being closed watertight at all times and kept closed during navigation.
✗
Question 83. A survey found the nautical publications on board out of date. What does SOLAS address?
Your Answer: (Not answered)
Correct Answer: C (A deficiency; publications must be kept corrected up to date, as out-of-date information affects safety of navigation)
💡 SOLAS V/27 requires charts and nautical publications to be kept corrected to the latest information and they are checked at survey. Out-of-date publications are a deficiency affecting safety of navigation, particularly in confined waters and on an unfamiliar coast, where they create a risk of grounding.
✗
Question 84. For passenger ships of less than 4 000 GT, the number of independently driven fire pumps required is:
Your Answer: (Not answered)
Correct Answer: C (not less than 2)
💡 SOLAS II-2/10 requires at least two independently driven fire pumps for passenger ships of less than 4 000 GT.
✗
Question 85. On what basis shall the master plan the voyage before departure?
Your Answer: (Not answered)
Correct Answer: B (All available information in preparing a detailed passage plan)
💡 All available information, in preparing a detailed passage plan.
✗
Question 86. What should be noted in using sound and light signals to indicate intentions?
Your Answer: (Not answered)
Correct Answer: A (Use them as prescribed, watch for conflict with the other vessel's intentions and coordinate by VHF if necessary)
💡 Sound and light signals should be used as prescribed when vessels are in sight of one another to indicate manoeuvring intentions or to propose a course of action, but they do not replace actual avoiding action. After making a signal the other vessel's response should be watched and VHF used to coordinate if necessary, preventing conflicting intentions.
✗
Question 87. What is the relationship between the Document of Compliance and the Safety Management Certificate?
Your Answer: (Not answered)
Correct Answer: D (The DOC is issued to the company and the SMC to the ship, both valid for not more than five years with intermediate verification)
💡 ISM Code 13 provides that the DOC is issued to the company and the SMC to the ship, each valid for not more than five years with intermediate verification, including an annual verification of the DOC, to remain valid.
✗
Question 88. A ship has double side skin, a single deck, top side tanks and hopper side tanks and carries ore in bulk. What is she under SOLAS XII/1?
Your Answer: (Not answered)
Correct Answer: D (A bulk carrier subject to the requirements of Chapter XII)
💡 SOLAS XII/1 defines a bulk carrier as a ship with a single deck, top side tanks and hopper side tanks intended primarily to carry dry cargo in bulk. An ore carrier meets the definition and must comply with Chapter XII.
✗
Question 89. What does SOLAS require regarding automatic controls and safety devices for main machinery and boilers?
Your Answer: (Not answered)
Correct Answer: B (Safety devices must be fitted to give warning or take action automatically when parameters become abnormal, preventing damage)
💡 SOLAS II-1 requires safety devices for propulsion machinery and boilers that warn or act automatically on abnormal conditions such as low lubricating oil pressure or high cooling water temperature, preventing damage.
✗
Question 90. When shall the annual survey of a ship be carried out?
Your Answer: (Not answered)
Correct Answer: A (Within three months before or after the anniversary date)
💡 The annual survey is held within three months before or after the anniversary date.
✗
Question 91. What is required for checking the windlass and anchor cable?
Your Answer: (Not answered)
Correct Answer: A (Periodic checks of the windlass brake and clutch and the wear of the cable, ensuring reliable anchoring)
💡 The windlass brake and clutch and the anchor cable with its stopper should be checked periodically for wear and corrosion, ensuring reliable operation when anchoring is needed in an emergency. A failed windlass deprives the ship of her last resort at a critical moment, particularly in confined waters.
✗
Question 92. A class divisions on a passenger ship shall be capable of preventing the passage of smoke and flame to the end of a 60-minute standard fire test. The fire integrity is:
Your Answer: (Not answered)
Correct Answer: B (determined by structure, generally not less than 60 minutes)
💡 A class divisions are defined to withstand a standard fire test for 60 minutes without passage of smoke and flame.
✗
Question 93. What is the correct action if a pan of oil catches fire in the galley?
Your Answer: (Not answered)
Correct Answer: A (Shut off the heat, smother with a lid or fire blanket and use the galley fixed extinguishing system)
💡 Oil burning in a pan should be dealt with by shutting off the heat and smothering with a lid or fire blanket, or by releasing the galley fixed extinguishing system. Water makes hot oil splash and spreads the fire, and carrying a burning pan out is even more dangerous.
✗
Question 94. What is the main purpose of the requirements for fire main diameter and pressure?
Your Answer: (Not answered)
Correct Answer: A (To ensure that the required number of jets can be supplied simultaneously with effective reach)
💡 The SOLAS II-2 requirements for fire main diameter and pressure ensure that the required number of jets can be maintained simultaneously at an effective reach when the fire pumps are running.
✗
Question 95. Before departure, a steering gear test shall be carried out to:
Your Answer: (Not answered)
Correct Answer: A (verify that the main and emergency steering gear are working properly)
💡 SOLAS V/12: a steering gear test shall be carried out before departure to verify that the main and emergency steering gear work properly.
✗
Question 96. If a ship fails a survey because of an equipment deficiency, what may the Administration do?
Your Answer: (Not answered)
Correct Answer: B (Require rectification within a period and re-inspect afterwards, with the validity of the certificate possibly affected meanwhile)
💡 SOLAS I/12 permits the Administration to suspend or withdraw a certificate where the ship does not comply. In practice rectification within a period and re-inspection is required before validity is maintained or restored. A certificate must not be issued with a deficiency outstanding.
✗
Question 97. What is the use of the maximum permissible centre of gravity curve in the stability information?
Your Answer: (Not answered)
Correct Answer: D (To judge quickly during loading whether the centre of gravity exceeds the permissible value at each displacement)
💡 The curve or table of maximum permissible height of the centre of gravity gives the permissible value for each displacement, so that during loading the calculated actual height can simply be compared with it to judge whether stability is satisfactory, without computing the full stability curve each time.
✗
Question 98. At the change of watch, which statement about what should be handed over is correct?
Your Answer: (Not answered)
Correct Answer: A (Course and speed, position, traffic situation, condition of the ship's equipment and existing risks and other essential information)
💡 The change of watch should ensure that the relieving officer takes responsibility with a full understanding of the situation, including course and speed, position and passage plan, traffic and intentions, equipment condition and alarms, weather and visibility, and existing risks and outstanding matters. A poor handover is a common cause of navigational accidents.
✗
Question 99. Which load is NOT among those supplied by the emergency source of power?
Your Answer: (Not answered)
Correct Answer: B (Cargo handling equipment)
💡 The emergency source supplies safety-related loads, not cargo handling equipment.
✗
Question 100. What is the purpose of isolating valves in the fire main?
Your Answer: (Not answered)
Correct Answer: B (Isolating the damaged section while maintaining supply elsewhere)
💡 They isolate a damaged section while the rest of the main remains in service.