Question 1. During the voyage the temperature records for a solid bulk cargo show a steady rise. What treatment of the matter is acceptable for the master?
Your Answer: (Not answered)
Correct Answer: C (testing made more frequent and the cause looked into, ventilation or sealing decided by what the cargo schedule requires, company and port informed)
💡 The Code prescribes different treatment by cargo: some self-heating materials want surface ventilation to carry heat off, others must have air restricted so the oxygen does not feed the reaction, and carbon dioxide is released in one dose to the designed concentration once the space is proved clear and tight. The basis is the proper name, the moisture and the trend, not the single clue of a rising thermometer; opening a hold can also bring smoke back over the working party. Closer record-keeping, report and measurement are the practical ship's side of it.
✗
Question 2. Which extinguishing medium should be used on an electrical fire?
Your Answer: (Not answered)
Correct Answer: A (A non-conducting medium such as CO2 or dry powder, with the power cut first)
💡 An electrical fire requires a non-conducting medium such as CO2 or dry powder with the power cut as soon as possible. Water or foam risks electric shock and further damage to equipment, and cutting the power is the first step.
✗
Question 3. Under SOLAS V/26, radar shall be used:
Your Answer: (Not answered)
Correct Answer: A (in restricted visibility and congested waters to maintain safe navigation)
💡 SOLAS V/26: radar shall be used in restricted visibility and congested waters to maintain safe navigation.
✗
Question 4. An inflatable liferaft shall:
Your Answer: (Not answered)
Correct Answer: B (inflate automatically when launched and also be capable of manual inflation)
💡 SOLAS III/36 (LSA Code) requires an inflatable liferaft to inflate automatically when launched, with manual inflation also provided.
✗
Question 5. What principle governs the selection of electrical equipment within the cargo area of a tanker?
Your Answer: (Not answered)
Correct Answer: D (Equipment of an explosion-protected type appropriate to the hazard level of the area must be used)
💡 SOLAS II-2 requires electrical equipment in hazardous areas of a tanker to be of an explosion-protected type suited to the hazard level. Ordinary equipment is not permitted even with more frequent inspection.
✗
Question 6. A Cargo Ship Safety Construction Certificate shall be issued for a period not exceeding:
Your Answer: (Not answered)
Correct Answer: C (5 years)
💡 SOLAS I/12 requires a Cargo Ship Safety Construction Certificate for a period not exceeding 5 years.
✗
Question 7. For a cargo ship of 100 m and above, the number of lifebuoys with self-igniting lights shall be not less than:
Your Answer: (Not answered)
Correct Answer: B (8)
💡 SOLAS III/32 requires not less than eight lifebuoys with self-igniting lights for cargo ships of 100 m and above.
✗
Question 8. For how long at least should the backup power of an ECDIS keep it working?
Your Answer: (Not answered)
Correct Answer: B (At least thirty minutes)
💡 Under SOLAS V/19.2.6 an ECDIS should have a backup power supply able to keep it working for at least thirty minutes if the main or emergency source fails, so that essential navigational information is not interrupted. The condition of the backup supply such as a UPS should be included in checks and maintenance.
✗
Question 9. Which system, directly related to fire protection, is required in accommodation and service spaces?
Your Answer: (Not answered)
Correct Answer: B (Fixed fire detection and alarm system)
💡 SOLAS II-2/12 requires fixed fire detection and alarm systems in accommodation and service spaces.
✗
Question 10. What is the effect of contamination of a fire detector by oil fume or dust?
Your Answer: (Not answered)
Correct Answer: C (It may cause false alarms or reduced sensitivity leading to a missed alarm, so periodic cleaning and maintenance are required)
💡 A detector contaminated by oil, dust or moisture may give frequent false alarms or lose sensitivity and miss an alarm. It should therefore be cleaned and function tested at the prescribed intervals, especially in heavily contaminated spaces such as the galley and machinery space.
✗
Question 11. What do SOLAS and good practice address regarding the inspection of the propulsion shafting?
Your Answer: (Not answered)
Correct Answer: A (Periodic inspection of the tail shaft, intermediate shaft and bearings for wear, sealing and alignment)
💡 SOLAS and the classification societies require periodic inspection of the propulsion shafting for stern tube sealing, bearing wear and alignment, detecting abnormalities that could cause oil leakage, vibration or shaft failure with loss of propulsion.
✗
Question 12. What does the Polar Code address regarding equipment for low temperature in polar waters?
Your Answer: (Not answered)
Correct Answer: A (Materials and operating temperatures of essential equipment must suit the low temperatures, preventing brittle fracture and failure)
💡 The Polar Code requires essential equipment, materials and systems of a ship in polar waters to be designed for low temperatures, preventing failure through brittle fracture of steel, increased viscosity of hydraulic oil or reduced battery capacity.
✗
Question 13. Where must the muster list be posted?
Your Answer: (Not answered)
Correct Answer: A (On the bridge and in the spaces where emergency duties are assigned)
💡 The muster list is posted on the bridge and at each station where emergency duties are performed.
✗
Question 14. What preparation is required before new equipment is brought into use?
Your Answer: (Not answered)
Correct Answer: A (Familiarisation training completed, procedures and checklists revised and the item included in the maintenance programme)
💡 Before new or replacement equipment is brought into use, the crew should complete familiarisation training covering operation, emergencies and maintenance, the relevant procedures and checklists be revised, the item included in the maintenance programme and the effect on the system documentation considered, preventing errors from unfamiliarity.
✗
Question 15. A lifeboat shall be provided with at least how many rocket parachute flares?
Your Answer: (Not answered)
Correct Answer: B (4)
💡 SOLAS III/34 requires at least four rocket parachute flares in a lifeboat.
✗
Question 16. What should the ventilation measures meet before entering an enclosed space?
Your Answer: (Not answered)
Correct Answer: A (Adequate ventilation should be provided and the atmosphere tested as satisfactory before entry, with continuous ventilation and an attendant during the work)
💡 Before entering an enclosed space adequate ventilation should be provided and the atmosphere tested for oxygen, flammable gas and toxic gas and confirmed satisfactory, and during entry ventilation should be continuous, an attendant stationed at the entrance and communication maintained. Entry without ventilation, testing or an attendant is prohibited.
✗
Question 17. The packaging of dangerous goods shall:
Your Answer: (Not answered)
Correct Answer: C (comply with the packing requirements of the IMDG Code and be properly marked and labelled)
💡 SOLAS VII/3 requires packaging in accordance with the IMDG Code with proper marking and labelling.
✗
Question 18. What is required in managing certificates of competence?
Your Answer: (Not answered)
Correct Answer: A (Ensure they are valid and appropriate to the position held and produce them for port State inspection as required)
💡 The certificates of competence, training certificates and medical certificates of the crew should be kept valid and appropriate to the positions held, kept safely on board and produced at inspection. Expired certificates or a mismatch with the position held is a serious deficiency and may lead to the ship being detained or the crew member being required to be replaced.
✗
Question 19. A VDR shall record:
Your Answer: (Not answered)
Correct Answer: D (date/time, position, speed, heading, bridge audio and other data)
💡 SOLAS V/20: a VDR records date/time, position, speed, heading, radar images and bridge audio.
✗
Question 20. How many security levels are established under the ISPS Code?
Your Answer: (Not answered)
Correct Answer: A (Three)
💡 The ISPS Code establishes three security levels: 1, 2 and 3.
✗
Question 21. A ship is found not to have carried out and recorded the emergency steering drill within the recent period. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Emergency steering drills must be held and recorded at the required intervals; failure is an SMS and operational deficiency)
💡 Emergency steering drills should be held at regular intervals so that the crew are familiar with the procedures for steering by the emergency steering gear when the main steering fails. Failure to hold or record them shows that emergency preparedness and training are inadequate. It is a deficiency to be corrected.
✗
Question 22. What does the Ship Security Officer's duty include?
Your Answer: (Not answered)
Correct Answer: B (Implementation of the SSP and security training)
💡 Implementation of the SSP and security training.
✗
Question 23. What does SOLAS address regarding the stowage of lifebuoys?
Your Answer: (Not answered)
Correct Answer: C (Stowed where they can be quickly released, not locked or lashed)
💡 SOLAS requires lifebuoys to be stowed so they can be released at once. Locking them or lashing them down means a lifebuoy cannot be thrown immediately when a person falls overboard, a common deficiency.
✗
Question 24. What does A-60 mean in the context of class A fire divisions?
Your Answer: (Not answered)
Correct Answer: B (That the division prevents passage of smoke and flame and limits temperature rise for 60 minutes in the standard fire test)
💡 Class A divisions are graded A-60, A-30, A-15 and A-0 by the duration for which they prevent passage of smoke and flame and limit temperature rise in the standard fire test. The number is a duration in minutes, not a thickness.
✗
Question 25. To which tankers does the emergency towing arrangement requirement of SOLAS II-1/3-3 apply?
Your Answer: (Not answered)
Correct Answer: D (Oil tankers of 20000 tonnes deadweight and above)
💡 SOLAS II-1/3-3 requires oil tankers of 20000 tonnes deadweight and above to be fitted with an emergency towing arrangement at bow and stern, so that a disabled tanker can be taken in tow. It is not limited to new ships.
✗
Question 26. What routine maintenance does the fire main require?
Your Answer: (Not answered)
Correct Answer: A (Periodic checks for corrosion and leakage, freedom of valve operation and prevention of water standing and freezing in the pipe)
💡 The fire main should be checked periodically for corrosion and leakage of the pipe wall and for freedom of valve operation, with standing water prevented from freezing in cold weather and periodic pressure testing, ensuring the system works reliably when needed.
✗
Question 27. What preparations should a ship make before an annual survey?
Your Answer: (Not answered)
Correct Answer: A (Keep equipment in good order and have records, certificates and survey reports ready so that the survey proceeds smoothly)
💡 Before a survey, equipment should be in working order, records and certificates available, routine maintenance completed and known problems dealt with, avoiding deficiencies, or even an effect on the validity of certificates, from equipment not working or records missing.
✗
Question 28. May AIS be switched off while the ship is under way? What is the position of SOLAS V?
Your Answer: (Not answered)
Correct Answer: A (AIS must remain in operation; it may be switched off only where the master considers this necessary for safety or security, with the reason recorded)
💡 SOLAS V/19.2.10 requires AIS to remain in operation, permitting it to be switched off only where the master believes its operation might compromise the safety or security of the ship, with the reasons entered in the log.
✗
Question 29. Which of the following is supplied from the emergency source of power?
Your Answer: (Not answered)
Correct Answer: A (Emergency lighting, navigation lights, radio installation and steering gear related equipment, among others)
💡 SOLAS II-1/42 lists the emergency services, including emergency lighting, navigation lights, the GMDSS installation, steering gear and, where applicable, the emergency fire pump. Lighting is only one of them.
✗
Question 30. What does SOLAS V require of the master when heavy weather is encountered at sea?
Your Answer: (Not answered)
Correct Answer: D (To take appropriate measures to safeguard the ship, altering course or speed if necessary, and to report to the company)
💡 SOLAS V/33 places responsibility for the safety of the ship and persons on board on the master, who must take measures such as sheltering, altering course or reducing speed, and must report under the SMS.
✗
Question 31. Under typical conditions (antenna height and SART height of 1 m), a SART should be detectable at a range of about:
Your Answer: (Not answered)
Correct Answer: D (5 nm)
💡 SOLAS IV/7: a SART should be detectable at a range of about 5 nautical miles under typical conditions.
✗
Question 32. What do COLREG and SOLAS require for overtaking in a narrow channel?
Your Answer: (Not answered)
Correct Answer: D (The overtaking vessel must obtain the agreement of the vessel being overtaken and keep a sufficient distance)
💡 COLREG Rule 9 requires a vessel intending to overtake in a narrow channel to obtain the agreement of the vessel to be overtaken, normally by VHF or sound signal, and to pass at a sufficient distance. Overtaking without agreement risks collision.
✗
Question 33. What is required for the height of liferaft stowage?
Your Answer: (Not answered)
Correct Answer: A (Stowed at a height allowing the raft to float free and allowing persons to board and handle it)
💡 A liferaft should be stowed at a height that allows it to float free, clear of deck structures, and that permits persons to board and handle it, normally on a dedicated rack on the boat deck. Too high makes boarding difficult; too low risks damage by seas or prevents free floating.
✗
Question 34. The firefighter's outfit store is found locked with the key not readily available, so difficult to obtain in an emergency. The finding is?
Your Answer: (Not answered)
Correct Answer: B (Firefighter's outfits must be readily available; improper stowage is a deficiency affecting firefighting readiness)
💡 The firefighter's outfits and their associated equipment should be stowed in a location that is easily reached and readily available. If locked with the key not promptly available it delays the donning and entry of the firefighters at the start of a fire. It is a deficiency affecting firefighting readiness.
✗
Question 35. The intermediate verification of a Safety Management Certificate shall be carried out:
Your Answer: (Not answered)
Correct Answer: A (around the mid-point of the certificate's validity)
💡 SOLAS IX/4 (ISM) requires intermediate verification around the mid-point of the SMC validity.
✗
Question 36. A bypass pipe allowing oily water to be discharged overboard while circumventing the oily water separator is found on board. The finding is?
Your Answer: (Not answered)
Correct Answer: C (An illegal bypass is a serious violation that may lead to detention and administrative penalty)
💡 Oily water must be processed and meet the discharge standard before discharge. Fitting a bypass pipe to discharge overboard while circumventing the separator is a serious violation evading pollution prevention rules. Once found it is not only a detainable deficiency but may also trigger administrative penalty and investigation.
✗
Question 37. What is the role of the echo sounder in berthing and narrow channel navigation?
Your Answer: (Not answered)
Correct Answer: C (To provide a real-time depth reading and assist in judging under-keel clearance)
💡 The echo sounder gives a real-time depth reading, helping the officer judge under-keel clearance in shoal water, narrow channels and when berthing, preventing grounding. It does not replace position fixing equipment.
✗
Question 38. A certificate exempting a ship from certain convention requirements is called:
Your Answer: (Not answered)
Correct Answer: C (An Exemption Certificate)
💡 An Exemption Certificate is issued where special construction makes full compliance impracticable.
✗
Question 39. Which statement about the changeover to emergency steering is correct?
Your Answer: (Not answered)
Correct Answer: B (Emergency steering should be possible in the steering gear space or at an alternative position, and the crew should be familiar with the operating and communication procedures)
💡 Under SOLAS II-1/29 and the operational requirements emergency steering should be possible in the steering gear space or at a designated alternative position, with communication to the bridge by direct telephone or as required. The crew should become familiar with the changeover and steering procedures through emergency steering drills, and test records should be retained.
✗
Question 40. What does SOLAS address regarding the location of the emergency fire pump?
Your Answer: (Not answered)
Correct Answer: A (Located outside the machinery space with independent power and a separate suction)
💡 SOLAS requires the emergency fire pump to be located outside category A machinery spaces with an independent source of power and a separate suction, so that it is not affected by a fire in that space and can draw water independently.
✗
Question 41. What must be provided in the steering gear compartment under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (Arrangements to control the steering gear and to operate the machinery on emergency)
💡 SOLAS requires the steering gear compartment to have arrangements for controlling the steering gear and for operating the machinery on emergency, such as emergency stopping, making it an emergency control centre.
✗
Question 42. What is the maximum extension the Administration may grant to an expired certificate?
Your Answer: (Not answered)
Correct Answer: B (5 months)
💡 An extension of not more than 5 months may be granted.
✗
Question 43. Before departure, a steering gear test shall be carried out to:
Your Answer: (Not answered)
Correct Answer: A (verify that the main and emergency steering gear are working properly)
💡 SOLAS V/12: a steering gear test shall be carried out before departure to verify that the main and emergency steering gear work properly.
✗
Question 44. With regard to the IMO Ship Identification Number, it shall be:
Your Answer: (Not answered)
Correct Answer: B (permanent and marked on the hull)
💡 SOLAS XI-1/3: a ship shall have a permanent IMO Ship Identification Number marked on the hull and shown on certificates.
✗
Question 45. With regard to the stability of a grain-laden ship:
Your Answer: (Not answered)
Correct Answer: C (the effect of grain shift shall be considered and the Grain Code stability requirements met)
💡 SOLAS VI/6 requires consideration of grain shift and compliance with the International Grain Code stability requirements.
✗
Question 46. An 80 m cargo ship is under plan approval. What does SOLAS II-1/10 require regarding the double bottom?
Your Answer: (Not answered)
Correct Answer: A (For ships of 76 m and above a double bottom shall be fitted as far as practicable between the collision and afterpeak bulkheads)
💡 SOLAS II-1/10 requires a double bottom, as far as practicable, between the collision bulkhead and the afterpeak bulkhead for cargo ships of 76 m and above. It does not require it throughout the whole ship.
✗
Question 47. What should be noted about using survival craft at low temperature in polar waters?
Your Answer: (Not answered)
Correct Answer: B (Difficulty in starting engines, reduced battery capacity and changed equipment performance, with insulation and pre-heating measures taken)
💡 Using survival craft in polar conditions requires attention to difficulty in starting engines, addressed by insulation, pre-heating and oil suited to low temperature, reduced battery capacity, addressed by insulation or spares, changed performance of equipment and the risk of hypothermia, with plans and drills in place.
✗
Question 48. What does SOLAS require regarding the starting arrangements for fire pumps?
Your Answer: (Not answered)
Correct Answer: C (They must be capable of remote starting from the bridge or fire control station, with means at the hydrants to start a pump)
💡 SOLAS requires fire pumps to be capable of remote starting by the watchkeeper from the bridge or a fire control station, with means at the hydrants to start a pump, so water is available quickly in a fire.
✗
Question 49. How must ballast be managed during cargo operations on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: A (Adjust the ballast in step with the cargo work as the loading plan provides, controlling hull stress and draught)
💡 Cargo and ballast operations on a bulk carrier should proceed together, with the plan setting out the ballast work for each stage, so as to control hogging and sagging, draught and stability. Adjusting the ballast only after cargo work would overstress the hull during the operation and cause structural damage.
✗
Question 50. What attention must be paid to crew mental health and fatigue?
Your Answer: (Not answered)
Correct Answer: C (Attention to the effect of mental state and fatigue on safety, mitigated by sensible work and rest arrangements and communication)
💡 The MLC and STCW require attention to the mental health and fatigue of the crew, addressed by sensible arrangement of work and rest, maintained lines of communication and support and improved living conditions. Fatigue and mental stress affect judgement and performance and are major contributors to accidents.
✗
Question 51. How many fire pumps are required on a passenger ship of 4000 GT and above?
Your Answer: (Not answered)
Correct Answer: D (Three)
💡 At least three.
✗
Question 52. What does SOLAS address regarding zoning of fire detection systems?
Your Answer: (Not answered)
Correct Answer: C (The system must identify the section in which the alarm originated, enabling the fire to be located quickly)
💡 SOLAS requires fixed fire detection systems to be arranged in sections so that the alarm indicates the section or space in which it originated, enabling the watchkeeper to confirm the actual location and act quickly.
✗
Question 53. What is the main purpose of the main engine and steering gear information required on board?
Your Answer: (Not answered)
Correct Answer: B (To enable the master to know the machinery and steering response and plan safe manoeuvres)
💡 SOLAS requires information on the main engine and steering gear so the master understands acceleration, deceleration and steering response, and can plan berthing and narrow channel manoeuvres.
✗
Question 54. What is the basic requirement of SOLAS for protection against electric shock?
Your Answer: (Not answered)
Correct Answer: A (Live parts must be protected, and safety voltage or isolation used in hazardous locations)
💡 SOLAS requires exposed live parts to be protected and safety voltage or isolation and residual current protection to be used in damp or metal-enclosed locations, reducing the risk of electric shock.
✗
Question 55. For a cargo ship of 2000 GT and above, the auxiliary steering gear shall put the rudder over how quickly?
Your Answer: (Not answered)
Correct Answer: C (From 15° one side to 15° the other in not more than 30 seconds)
💡 SOLAS II-1/29: the auxiliary steering gear shall be capable of putting the rudder over in 30 seconds.
✗
Question 56. What shall the master do on encountering dangerous ice or derelicts?
Your Answer: (Not answered)
Correct Answer: B (Communicate the danger immediately to ships in the vicinity and to the competent authority ashore)
💡 SOLAS V/31: the master shall communicate the danger immediately to nearby ships and to the competent authority.
✗
Question 57. What is the scope of application of the ISPS Code?
Your Answer: (Not answered)
Correct Answer: D (Ships of 500 GT and above engaged on international voyages and the port facilities serving them)
💡 SOLAS XI-2 and the ISPS Code apply to ships of 500 GT and above on international voyages and to the port facilities serving such ships, not to all ships.
✗
Question 58. If the Inmarsat equipment fails while a ship is in sea area A3, what alternative does SOLAS permit?
Your Answer: (Not answered)
Correct Answer: A (Using MF/HF equipment to meet the distress and safety communication requirements)
💡 Where the primary satellite equipment fails, the ship must use MF/HF to maintain distress and safety communication in sea area A3. Reliance on another ship or on repair is not acceptable.
✗
Question 59. What does SOLAS address regarding the relationship between survey intervals and the validity of certificates?
Your Answer: (Not answered)
Correct Answer: B (The validity period corresponds to the survey cycle, and failure to survey in time makes the certificate invalid)
💡 SOLAS links the survey cycle to the validity of the certificate: the initial, annual or intermediate and renewal surveys are the conditions for maintaining validity. Failure to carry out any of them in time affects the validity of the certificate.
✗
Question 60. What is the first action required when a person falls overboard, under SOLAS and the related rules?
Your Answer: (Not answered)
Correct Answer: C (Raise the alarm immediately, report to the bridge, keep the person in sight and carry out a Williamson or Scharnow turn as necessary)
💡 STCW and SOLAS require immediate alarm, keeping the person in sight, throwing a lifebuoy and manoeuvring the ship back to the position as quickly as possible. Waiting for another ship or abandoning ship is not a correct response.
✗
Question 61. In the periodic inspection of lifeboat davits, what does SOLAS require particular attention to?
Your Answer: (Not answered)
Correct Answer: B (Structural corrosion, sheave wear and the reliability of limit switches and release gear)
💡 Davit inspection concentrates on structural corrosion, wear of sheaves and falls, and the reliability of limit switches and on-load release gear, all of which determine whether the boat can be launched safely.
✗
Question 62. What is recommended when cargo in a hold self-heats and ignites?
Your Answer: (Not answered)
Correct Answer: C (Close the hold ventilation and openings and use the fixed extinguishing system or measures suited to the cargo)
💡 When cargo in a hold ignites, ventilation and openings should be closed to limit the oxygen available and the fixed extinguishing system, such as CO2, or measures suited to the cargo, such as flooding, used. Opening the hold for ventilation admits large quantities of air and feeds the fire, an incorrect response.
✗
Question 63. What protection against freezing is required for bilge and fire piping in cold weather?
Your Answer: (Not answered)
Correct Answer: C (Drain or insulate piping liable to freeze, preventing water in it freezing and bursting the pipe)
💡 In cold weather the bilge, fire and ballast piping liable to freeze should be protected by draining, insulation or trace heating, preventing trapped water from freezing and expanding to burst the pipe or valves and so impairing the supply and drainage capability needed in an emergency.
✗
Question 64. What is the function of the bridge navigational watch alarm system?
Your Answer: (Not answered)
Correct Answer: A (To raise an alarm if the officer of the watch becomes incapacitated, alerting the master or another crew member)
💡 BNWAS monitors the activity of the officer of the watch and, if he becomes incapacitated, first gives a local alarm and then alerts the master or another crew member, preventing an unattended bridge. It neither steers the ship nor detects collision risk.
✗
Question 65. Which persons are not counted as passengers under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (Children under one year of age)
💡 Children under one year of age are not counted.
✗
Question 66. Where are firefighter's outfits stowed?
Your Answer: (Not answered)
Correct Answer: B (distributed over two or more readily accessible spots, clearly marked and lit, one still reachable if another is cut off)
💡 One question decides the stowage: can they still be reached when a fire is burning. The positions are to be readily accessible, plainly marked and permanently lighted, and distributed according to the size and layout of the ship so that a fire or a space full of smoke does not put every outfit out of reach. How many outfits, with the breathing sets and spares that go with them, is separately laid down; apart does not mean scattered, and each location must serve on its own. To lock them in a store and fetch the key when the alarm goes, to group them where the watchkeeper sits, to keep them with the paperwork because that is easy to register, all push the moment of use later, and a fire does not wait. The periodic check covers the positions as well: goods stacked in front of them, a dead light, a fallen sign, each makes sound gear unreachable.
✗
Question 67. Which spaces must emergency lighting cover at a minimum under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (Embarkation stations, survival craft stowage positions, escape routes, machinery spaces and the bridge, among other essential spaces)
💡 SOLAS requires emergency lighting for essential spaces including embarkation stations, survival craft stowage positions, escape routes, machinery spaces, the bridge and fire control stations, supporting abandonment and emergency operations.
✗
Question 68. What do SOLAS and STCW emphasise about the master's instructions to the officer of the watch?
Your Answer: (Not answered)
Correct Answer: D (The master should issue clear standing and night orders, which the watchkeeper follows, with the orders recorded)
💡 STCW and SOLAS require the master to issue clear standing orders and night orders, normally in writing, which the officer of the watch is familiar with and follows, calling the master immediately in any unforeseen situation.
✗
Question 69. A cargo ship completed its renewal survey in June 2020. Under SOLAS I/10, when must the subsequent annual surveys be held?
Your Answer: (Not answered)
Correct Answer: D (Every 12 months, within three months before or after the anniversary date)
💡 SOLAS I/10 requires annual surveys every 12 months, normally within a window of three months before or after the anniversary date.
✗
Question 70. Liferafts shall be stowed so that they:
Your Answer: (Not answered)
Correct Answer: A (float free automatically if the ship sinks before manual release)
💡 SOLAS III/13 requires liferafts to be stowed to float free automatically, using a hydrostatic release unit.
✗
Question 71. What does SOLAS address regarding automatic and remote control of propulsion machinery?
Your Answer: (Not answered)
Correct Answer: B (The control system must have the necessary alarms, monitoring and protection, retaining basic manoeuvring capability if it fails)
💡 SOLAS requires the control system of the main propulsion machinery to have alarms and monitoring, such as fault and parameter deviation alarms, and to retain basic manoeuvring capability through local control or other means if the control system fails.
✗
Question 72. An A-60 class division means a division capable of withstanding a standard fire test for:
Your Answer: (Not answered)
Correct Answer: D (60 minutes)
💡 SOLAS II-2/3: an A-60 class division is an A class division capable of withstanding a standard fire test for 60 minutes.
✗
Question 73. What is required when using electrical tools in a paint locker?
Your Answer: (Not answered)
Correct Answer: A (Confirm adequate ventilation and vapour concentration within safe limits and use explosion-protected or intrinsically safe tools, restricting the work if necessary)
💡 Flammable vapour may accumulate in a paint locker. Before using electrical or spark-producing tools, adequate ventilation and vapour concentration within safe limits should be confirmed and explosion-protected or intrinsically safe tools used, with the work prohibited inside the locker if necessary.
✗
Question 74. What should be checked about the type approval marking of life-saving appliances?
Your Answer: (Not answered)
Correct Answer: C (That the appliance bears the approval marking or certificate number of the Administration or a recognised body)
💡 SOLAS and the LSA Code require life-saving appliances to be type approved and to bear the approval marking or certificate number. On inspection the marking should be clear and consistent with the certificate. Appliances without an approval mark may not be accepted by the surveyor or the PSC, and are a deficiency.
✗
Question 75. What is the purpose of the ship security assessment?
Your Answer: (Not answered)
Correct Answer: C (To identify security risks and weaknesses of the ship, forming the basis for the ship security plan)
💡 ISPS Code Part A/6 requires a ship security assessment identifying security risks, weaknesses and possible threats, the results of which form the basis for developing and updating the ship security plan.
✗
Question 76. Where must the valves of the bilge system be operable under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (From a readily accessible position in the machinery space, and by remote operation when required)
💡 SOLAS requires bilge system valves to be arranged for operation from a readily accessible position and to be capable of remote operation where necessary, avoiding the need for personnel to enter a space that may be flooding or on fire.
✗
Question 77. What is required in setting the safety contour on ECDIS?
Your Answer: (Not answered)
Correct Answer: D (Set it in accordance with the ship's draught and the required under-keel clearance so that it reflects the actual safe depth)
💡 The safety contour and safety depth on ECDIS should be set according to the ship's draught, her under-keel clearance policy and the depths of the area, so that the system alarms accurately when approaching shoal water. An unsuitable default setting may make the alarm ineffective or cause constant false alarms.
✗
Question 78. Before a container is packed a packing certificate must be signed. Who issues this document?
Your Answer: (Not answered)
Correct Answer: B (The container packing certificate, issued by the person or organisation responsible for packing)
💡 SOLAS VII/6 requires the container packing certificate to be issued by the person or organisation that packed the container, confirming compliance with the IMDG Code. The master, who is not the packer, cannot issue it.
✗
Question 79. When testing the auxiliary steering gear, what speed condition does SOLAS II-1/29 require?
Your Answer: (Not answered)
Correct Answer: D (Seven knots or one half of the maximum service speed, whichever is greater)
💡 SOLAS II-1/29 requires the auxiliary steering gear, at 7 knots or one half the maximum service speed (whichever is greater), to put the rudder over from 15 degrees to 15 degrees within 60 seconds.
✗
Question 80. Enhanced Surveys (ESP) apply to:
Your Answer: (Not answered)
Correct Answer: C (bulk carriers and oil tankers to which the requirements apply)
💡 SOLAS XI-1/2: Enhanced Surveys apply to bulk carriers and oil tankers to which the requirements apply.
✗
Question 81. What checking of survival craft stowage cradles is required?
Your Answer: (Not answered)
Correct Answer: C (Check the structure for corrosion and deformation and the lashings and limiters for reliability)
💡 Survival craft cradles should be checked for serious corrosion or deformation of the structure and for the reliability of the lashings and limiters, with the sliding surfaces smooth so that launching is unobstructed. Structural failure would prevent launching or allow the craft to move in a seaway, a serious hazard.
✗
Question 82. What do SOLAS and the IBC Code address regarding the operation of the inert gas system?
Your Answer: (Not answered)
Correct Answer: D (It must remain in operation with tank pressure and oxygen content monitored during cargo, ballast and tank cleaning operations)
💡 SOLAS and the IBC Code require the inert gas system to remain in operation during cargo handling, ballasting and tank washing, with the oxygen content and pressure of each tank monitored continuously. If limits are exceeded, operations must stop to avoid the risk of explosion.
✗
Question 83. On passenger ships, the width of means of escape shall:
Your Answer: (Not answered)
Correct Answer: A (meet the prescribed requirements for the number of persons to be evacuated)
💡 SOLAS II-2/13 requires escape routes and stairways to have the width prescribed for the number of persons.
✗
Question 84. What should be noted about the combined operation of watertight doors and the bilge system?
Your Answer: (Not answered)
Correct Answer: B (The interaction of door closure with bilge pumping should be considered, avoiding a change in heel or stability from pumping or flooding)
💡 Bilge pumping and ballast operations change the distribution of weight and the heel of the ship. They should be considered together with the open or closed state of the watertight doors, preventing pumping or flooding from increasing the list, altering stability or cross-connecting compartments, particularly when the ship is already damaged.
✗
Question 85. Why should the length and diameter of fire hoses meet the requirements?
Your Answer: (Not answered)
Correct Answer: B (To ensure the hose reaches the protected space, is easy to handle and does not affect discharge pressure)
💡 A fire hose should be of appropriate length and diameter: too long increases friction loss and reduces pressure, too short cannot reach the protected space. Every hydrant's hose should reach any position in the protected space requiring it and be suitable for operation by two persons.
✗
Question 86. After a distress alert sent by digital selective calling, on which frequency is the follow-up distress traffic made?
Your Answer: (Not answered)
Correct Answer: D (very high frequency moving to sixteen, medium frequency to two thousand one hundred and eighty-two kilohertz)
💡 Selective calling only puts the alert and the position out; the channel itself is not for speech. A very high frequency alert goes out on seventy and the traffic that follows is made on sixteen; the medium frequency alert is sent on two thousand one hundred and eighty-seven and a half kilohertz with the traffic on two thousand one hundred and eighty-two, high frequency having its own distress and safety frequencies. An alert is normally acknowledged by radiotelephony, and acknowledgements and relays are made on the frequency the rules assign, the alerting channel being kept clear. Treating seventy as a speech channel confuses the calling and the telephony sides of the system.
✗
Question 87. What communication backup is required in polar waters?
Your Answer: (Not answered)
Correct Answer: D (Backup means not depending on a single system, such as HF together with satellite, with consideration of reserve power)
💡 The Polar Code requires account to be taken of limited satellite coverage and possible loss of communication in polar regions, providing means not dependent on a single system, such as HF together with satellite equipment, reserve power and a spare antenna, and setting out the contingency arrangements if communication is lost.
✗
Question 88. For a hydraulic steering gear, provision shall be made to detect abnormal conditions by means of:
Your Answer: (Not answered)
Correct Answer: C (a tank level gauge with a low-level alarm)
💡 SOLAS II-1/29 requires a tank level gauge with a low-level alarm to monitor hydraulic fluid leakage.
✗
Question 89. How many hand flares must each survival craft carry?
Your Answer: (Not answered)
Correct Answer: A (Six)
💡 SOLAS III requires six hand flares in each survival craft, in addition to the four rocket parachute flares required separately. The two numbers are different.
✗
Question 90. What is the role of the designated person ashore under the ISM Code?
Your Answer: (Not answered)
Correct Answer: D (To monitor the safety and pollution prevention aspects of the ship's operation and ensure adequate resources and shore support)
💡 ISM Code 4 requires the company to designate a person or persons ashore to monitor the safety and pollution prevention aspects of the operation of each ship and to ensure adequate resources and shore support are provided, acting as the link between company and ship.
✗
Question 91. What valves and fittings does SOLAS require on fire pumps?
Your Answer: (Not answered)
Correct Answer: A (A relief valve and pressure gauge on each pump, preventing overpressure damage to the piping)
💡 SOLAS requires a relief valve and pressure gauge on each fire pump, preventing overpressure damage when the discharge valve is closed or the line is blocked, with the gauge enabling the watchkeeper to judge the water supply.
✗
Question 92. How should fire hoses be used in a fire drill?
Your Answer: (Not answered)
Correct Answer: C (Use hydrants and hoses at designated positions under the drill plan to verify the system, avoiding waste and damage to equipment)
💡 In a fire drill, hydrants and hoses should be used at designated safe positions to verify hose connection, nozzle handling and supply pressure, giving the crew practical experience. After using substantial water, drainage and anti-slip measures should be taken and cargo and equipment protected.
✗
Question 93. What corridor length limit does SOLAS address in the escape requirements for accommodation spaces?
Your Answer: (Not answered)
Correct Answer: B (An enclosed corridor exceeding 13 m must have escape routes at both ends)
💡 SOLAS II-2/13 requires an enclosed corridor more than 13 m long to have access to escape routes at both ends, so that persons are not trapped in a long corridor with a single exit.
✗
Question 94. What does SOLAS require regarding the arrangement of scuppers, inlets and discharges on a ship's sides?
Your Answer: (Not answered)
Correct Answer: C (They must not lead water into spaces where it would be dangerous, and reliable means of closure must be fitted)
💡 SOLAS II-1 regulates the arrangement and closing appliances of overboard scuppers and inlets so that water cannot enter spaces where it would create a hazard through damage or inadvertent operation.
✗
Question 95. What is the difference between the bulkhead deck and the freeboard deck under SOLAS II-1?
Your Answer: (Not answered)
Correct Answer: C (The bulkhead deck limits the extent of the main watertight bulkheads, while the freeboard deck is the datum for freeboard and load line)
💡 The bulkhead deck is the uppermost deck to which the main watertight bulkheads extend, whereas the freeboard deck is the datum for measuring freeboard and assigning load lines. Their roles in subdivision and load line calculations differ.
✗
Question 96. With regard to charts, which requirement is correct?
Your Answer: (Not answered)
Correct Answer: A (up-to-date charts covering the intended voyage shall be carried)
💡 SOLAS V/27 requires up-to-date charts covering the intended voyage.
✗
Question 97. Emergency lighting was tested and some survival craft embarkation stations had no lighting. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: C (Embarkation stations, survival craft stowage positions and the water alongside must be lit from the emergency source)
💡 SOLAS requires embarkation stations, survival craft stowage positions and the water alongside to be illuminated from the emergency source of power, ensuring safe abandonment. Torches are not a substitute for fixed emergency lighting.
✗
Question 98. A PSCO checked the escape arrangements from a category A machinery space. What does SOLAS require?
Your Answer: (Not answered)
Correct Answer: D (Two means of escape distant from each other, one of which may be an enclosed route)
💡 SOLAS II-2/13 requires two means of escape from a category A machinery space, remote from each other, normally two steel ladders one of which may be enclosed, so that one remains usable if the other is blocked by fire or smoke.
✗
Question 99. What do SOLAS and good practice address regarding fire safety in boiler spaces?
Your Answer: (Not answered)
Correct Answer: C (Quick closing valves and ventilation shut-off arrangements, with guarding and alarms around the boiler)
💡 SOLAS requires quick closing valves and ventilation shut-off arrangements in boiler spaces, with guarding around the boiler, preventing leaking fuel from being ignited by heat. The boiler space is a high fire risk location in the machinery space.
✗
Question 100. What does the weekly inspection of a lifeboat require regarding the engine?
Your Answer: (Not answered)
Correct Answer: A (Start and run it for the prescribed period, checking starting, running and cooling)
💡 SOLAS requires the boat engine to be started and run for the prescribed period, normally not less than three minutes, during the weekly inspection, checking that it starts readily, runs smoothly and discharges cooling water properly. An appearance or level check alone would not reveal an actual fault.