Exam Home Website
中文 English
0
/100
FAIL
Correct: 0/100 Total Questions: 100 Time Spent: 60min0sec
Passing: 80
Retake History
Answer Review
✗
Question 1. What does the Polar Code address regarding communication and navigation in polar waters?
Your Answer: (Not answered)
Correct Answer: A (Recognise that satellite coverage and the magnetic compass may be limited, and take measures to maintain communication and position fixing)
💡 The Polar Code requires account to be taken of limited satellite communication coverage in high latitudes, beyond geostationary satellite coverage, and the unreliability of the magnetic compass, with appropriate means such as HF and back-up navigation provided to maintain communication and position fixing in polar waters.
✗
Question 2. A PSCO tested ventilation closing devices and found some seized. What does SOLAS address?
Your Answer: (Not answered)
Correct Answer: A (Closing devices of machinery space ventilators must close rapidly to cut off ventilation and air supply)
💡 SOLAS II-2 requires machinery space ventilator closing devices to close rapidly and remain effective, cutting off the air supply in a fire. Seized devices or a lack of regular testing are common deficiencies.
✗
Question 3. Radio antennas shall be so installed that they can operate:
Your Answer: (Not answered)
Correct Answer: A (under all weather conditions with adequate protection)
💡 SOLAS IV/13 requires radio antennas to operate under all weather conditions with adequate protection.
✗
Question 4. What are the validity and intermediate audit requirements of the Safety Management Certificate (SMC)?
Your Answer: (Not answered)
Correct Answer: A (Validity generally not more than five years with an intermediate audit between the second and third anniversaries)
💡 Under the ISM Code the Safety Management Certificate has a usual validity of not more than five years, with an intermediate audit between the second and third anniversaries to confirm the continued effective operation of the system. Failure to audit on time invalidates the certificate.
✗
Question 5. Where must the valves of the bilge system be operable under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (From a readily accessible position in the machinery space, and by remote operation when required)
💡 SOLAS requires bilge system valves to be arranged for operation from a readily accessible position and to be capable of remote operation where necessary, avoiding the need for personnel to enter a space that may be flooding or on fire.
✗
Question 6. When peak and deep tanks are used as ballast tanks, what does SOLAS II-1 require of the ballast system?
Your Answer: (Not answered)
Correct Answer: B (It must be capable of safely filling and emptying ballast tanks under all operating conditions)
💡 SOLAS II-1 requires the ballast system to fill and empty tanks safely under all operating conditions so that draught and stability can be controlled. It is not confined to port use.
✗
Question 7. What is required for position monitoring when navigating in restricted waters?
Your Answer: (Not answered)
Correct Answer: B (Cross-check the position using several means such as visual bearings, radar and GPS, detecting any discrepancy early)
💡 SOLAS and good seamanship require the position in restricted waters to be cross-checked by several means, such as visual bearings, radar and GPS, detecting errors early. Reliance on a single means may lead to grounding through equipment error.
✗
Question 8. Where must the closing devices of main machinery space ventilation openings be operable?
Your Answer: (Not answered)
Correct Answer: A (From a readily accessible position outside the machinery space, clearly marked)
💡 SOLAS requires the closing devices of the main inlets and outlets of machinery space ventilation to be operable from a readily accessible position outside the machinery space, clearly marked, so that ventilation can be shut off in a fire without entering the space.
✗
Question 9. What is the principle for dealing with a risk of dragging anchor while at anchor?
Your Answer: (Not answered)
Correct Answer: D (Bring engines to readiness immediately, inform the bridge and master, and if necessary weigh or adjust the cable, warning nearby vessels)
💡 On a risk of dragging, engines should be brought to readiness at once, the bridge and master informed, cable veered or the anchor weighed as necessary, and nearby vessels warned, with the position monitored. Waiting or hesitating often leads to grounding or collision.
✗
Question 10. For a cargo ship with a double bottom, the minimum height of the inner bottom above the top of the keel at midships shall be:
Your Answer: (Not answered)
Correct Answer: D (B/20 or 2 m, whichever is less)
💡 SOLAS II-1/6: the double bottom height shall be not less than B/20 and in no case less than 760 mm; in machinery spaces it may be reduced to B/20 or 2 m, whichever is less.
✗
Question 11. How often must inflatable liferafts be serviced under SOLAS?
Your Answer: (Not answered)
Correct Answer: B (At intervals not exceeding 12 months at an approved servicing station)
💡 SOLAS requires inflatable liferafts to be serviced at intervals not exceeding 12 months at an approved servicing station, while rigid lifeboats are subject to the prescribed annual inspection. The crew cannot replace the approved servicing.
✗
Question 12. What determines the number of fireman's outfits to be carried?
Your Answer: (Not answered)
Correct Answer: A (The gross tonnage)
💡 The number of fireman's outfits is determined by the gross tonnage.
✗
Question 13. Where a certificate expires and the ship is not in a port of survey, the Administration may extend the certificate for a period not exceeding:
Your Answer: (Not answered)
Correct Answer: A (5 months)
💡 SOLAS I/14: where a ship is not in a port of survey at expiry, the Administration may extend the certificate for a period not exceeding 5 months.
✗
Question 14. What does SOLAS address regarding drawings and documents to be kept on board?
Your Answer: (Not answered)
Correct Answer: A (Approved drawings and information must be kept on board for inspection and use)
💡 SOLAS requires approved drawings and technical information such as stability information, fire control plans and cargo securing manuals to be kept on board for use by the crew and verification at surveys. Missing drawings prevent correct operation or survey.
✗
Question 15. What does SOLAS address regarding fire protection of the cargo pump room on a tanker?
Your Answer: (Not answered)
Correct Answer: D (Class A divisions at its boundaries with a fixed extinguishing system and fire detection inside)
💡 SOLAS requires the boundaries of a cargo pump room on a tanker to be class A divisions, with a fixed extinguishing system, normally CO2 or foam, and fire detection inside, since the pump room is a high risk space for accumulation and explosion of vapour.
✗
Question 16. What is required for closing appliances on overboard discharges below the load line?
Your Answer: (Not answered)
Correct Answer: B (Effective closing appliances operable from above the bulkhead deck, preventing back flooding)
💡 SOLAS and the Load Line Convention require discharges and inlets below the load line to have effective closing appliances such as non-return valves or cocks, operable from above the bulkhead deck, preventing sea water from entering. Temporary plugs of wood are not reliable.
✗
Question 17. What does routine checking of the bilge system include?
Your Answer: (Not answered)
Correct Answer: C (Strainers free of blockage, valves operating freely and pumps priming properly, with records kept)
💡 Routine checks of the bilge system should cover strainers and mud boxes for blockage and cleanliness, valves for free and correct operation and pumps for starting and priming, with records kept. Checking only in dry dock would leave the system failing in service without anyone knowing.
✗
Question 18. What is the legal status of annexes and attachments to statutory certificates under SOLAS?
Your Answer: (Not answered)
Correct Answer: D (They form part of the certificate, to be kept with it and produced for inspection)
💡 SOLAS requires annexes and attachments such as equipment records, exemption lists and survey records to form part of the certificate, kept with it and produced at port State inspection. Missing annexes make the certificate incomplete.
✗
Question 19. What is the meaning and use of an H class division?
Your Answer: (Not answered)
Correct Answer: A (The highest grade of fire-resisting division in the standard test, used for high risk boundaries such as pump rooms on tankers)
💡 An H class division is the highest grade of fire-resisting division under SOLAS, used for high risk boundaries such as the boundaries of cargo pump rooms on tankers. It exceeds class A performance and must retain structural integrity after the test.
✗
Question 20. Before proceeding to sea, the ship shall be:
Your Answer: (Not answered)
Correct Answer: A (ensured to be in all respects seaworthy, including adequate stability and trim)
💡 SOLAS V/34: before proceeding to sea the ship shall be ensured to be in all respects seaworthy, including adequate stability and trim.
✗
Question 21. A ship's enclosed escape route from the machinery space was used to store spare parts. What is the finding?
Your Answer: (Not answered)
Correct Answer: C (A serious deficiency, because the enclosed escape route must remain clear for evacuation)
💡 SOLAS requires the enclosed escape route to be kept clear for emergency evacuation. Using it to store articles obstructs evacuation and adds fire load, a deficiency seriously affecting safety.
✗
Question 22. An International Ship Security Certificate (ISSC) shall be issued for a period not exceeding:
Your Answer: (Not answered)
Correct Answer: C (5 years)
💡 SOLAS XI-2/3: an International Ship Security Certificate shall be issued for a period not exceeding 5 years.
✗
Question 23. What is the purpose of isolation valves on the fire main required by SOLAS?
Your Answer: (Not answered)
Correct Answer: B (To isolate a damaged section so the rest of the main can continue to supply water)
💡 SOLAS requires isolation valves on the fire main so that if a section, for example in the machinery space, is damaged, it can be isolated while the remainder still supplies the hydrants, preserving at least part of the firefighting capability.
✗
Question 24. From what source must emergency lighting in accommodation spaces and escape routes be supplied?
Your Answer: (Not answered)
Correct Answer: C (From the emergency source, automatically connected when the main source fails)
💡 SOLAS requires emergency lighting in escape routes and accommodation to be supplied from the emergency source and connected automatically when the main source fails, without manual switching. Main source supply would not illuminate when power is lost.
✗
Question 25. Ventilation must be shut down when a machinery space fire occurs. What does SOLAS II-2/12 require for closing ventilation openings of machinery spaces?
Your Answer: (Not answered)
Correct Answer: D (They shall be capable of being closed rapidly from outside the space)
💡 SOLAS II-2/12 requires ventilation openings of machinery spaces to be capable of being closed rapidly from outside the space, so ventilation can be stopped without entering the fire area.
✗
Question 26. What is required for maintenance and inspection of radio equipment?
Your Answer: (Not answered)
Correct Answer: A (Periodic inspection and maintenance to keep it ready for use)
💡 Periodic inspection and maintenance to keep it available at all times.
✗
Question 27. A 4200 GT cargo ship on international voyages has three pumps in the machinery space. Under SOLAS II-2/10.2, what is the minimum fire pump arrangement?
Your Answer: (Not answered)
Correct Answer: B (At least two independently driven fire pumps)
💡 SOLAS II-2/10.2 requires cargo ships of 1000 GT and above to have at least two independently driven fire pumps. At 4200 GT the ship is well above the threshold, so two is the minimum.
✗
Question 28. What is the principle for the food ration provided per person in the equipment of a lifeboat?
Your Answer: (Not answered)
Correct Answer: D (Not less than 10 000 kilojoules (about 2400 kilocalories) per person)
💡 Under SOLAS III/34 a lifeboat should carry a food ration of not less than ten thousand kilojoules, about twenty-four hundred kilocalories, for each person the boat is permitted to accommodate, to sustain them while awaiting rescue at sea after abandonment. The ration should be properly packed and within its shelf life.
✗
Question 29. A PSC inspection found the AIS switched off throughout the voyage. On what basis is this a deficiency?
Your Answer: (Not answered)
Correct Answer: C (AIS must remain in operation and may be switched off only where the master considers this necessary for safety or security)
💡 SOLAS V/19.2.10 requires AIS to remain in operation. It may be switched off only where the master believes its operation might compromise safety or security, with the reason and period recorded in the log. Leaving it off without justification is a deficiency.
✗
Question 30. What is the purpose of the emergency towing arrangement required on a tanker?
Your Answer: (Not answered)
Correct Answer: A (To enable the ship to be taken in tow quickly when the main engine or steering fails, reducing the risk of becoming a hazard)
💡 Under SOLAS II-1/3-4 a tanker should be provided with an emergency towing arrangement at the bow and stern so that it can be taken in tow quickly if the main engine or steering fails, reducing the risk of an accident and pollution when out of control in a busy or sensitive area. The arrangement should be capable of rapid deployment.
✗
Question 31. What is required for stowage and securing of containers?
Your Answer: (Not answered)
Correct Answer: B (Load according to the approved securing plan and stowage plan, securing tier by tier with attention to weight distribution and the order of lashing)
💡 SOLAS and the CSS Code require containers to be loaded in accordance with the approved securing plan and stowage plan, lashed tier by tier with attention to weight distribution, heavier boxes below and avoiding uneven loading, and to the order of lashing, with weights and conditions verified, preventing stack collapse or loss overboard.
✗
Question 32. Besides the proper shipping name, what must appear on a dangerous goods document?
Your Answer: (Not answered)
Correct Answer: C (The UN number and the hazard class)
💡 Dangerous goods documents must show the proper shipping name, UN number, class and packing group.
✗
Question 33. After a marine casualty such as a collision or grounding with serious loss, what is required of the master as to reporting?
Your Answer: (Not answered)
Correct Answer: C (Report to the flag Administration as required and, where necessary, to the nearest coastal State, and preserve the relevant records and information)
💡 Under SOLAS I/21 and related requirements, after a marine casualty the ship should report to the flag Administration as required and, where necessary, to the nearest coastal State, and should preserve evidence, the official log book and related records for the investigation. Concealing or delaying a report aggravates liability.
✗
Question 34. Where must the muster list be posted?
Your Answer: (Not answered)
Correct Answer: A (On the bridge and in the spaces where emergency duties are assigned)
💡 The muster list is posted on the bridge and at each station where emergency duties are performed.
✗
Question 35. What is the purpose of the safety contour and safety depth settings in ECDIS?
Your Answer: (Not answered)
Correct Answer: A (To warn automatically of shoal water and dangers by triggering safety alarms)
💡 The safety contour and safety depth define the navigable safe area and trigger automatic alarms when the ship approaches shoal water or dangers. They are central to passage monitoring.
✗
Question 36. The bridge arrangement shall ensure that:
Your Answer: (Not answered)
Correct Answer: D (The look-out is not obstructed from any direction)
💡 SOLAS V/22: the bridge must permit an unobstructed view all round from the conning position.
✗
Question 37. What minimum speed must a powered rescue boat be capable of maintaining in calm water with its full complement aboard?
Your Answer: (Not answered)
Correct Answer: B (6 knots)
💡 SOLAS III/17 requires a powered rescue boat to maintain at least 6 knots for not less than 4 hours. Four knots is a frequently confused figure.
✗
Question 38. What does SOLAS chapter II-2 require of the layout of fire mains and hydrants?
Your Answer: (Not answered)
Correct Answer: D (at least two jets reaching any part of the space protected, one of them on a single length of hose, with the specified fire pumps working)
💡 The chapter fixes the number of jets and the pressure by ship type: cargo ships as a rule require at least two jets from different hydrants, one of them available on a single length of hose to any part of the space protected, with separate requirements for machinery spaces. Main diameter, pump capacity and nozzle size have to match, or the far hydrant loses pressure. Layout follows coverage and simultaneous use, not ease of maintenance or a ratio of floor area, which tells nothing about jets.
✗
Question 39. On the navigation bridge, the main propulsion machinery shall be provided with:
Your Answer: (Not answered)
Correct Answer: A (indications of speed and direction of rotation and the necessary communication)
💡 SOLAS II-1/31 requires indications of propeller speed and direction and necessary communication on the bridge.
✗
Question 40. What does SOLAS address regarding SART batteries and testing?
Your Answer: (Not answered)
Correct Answer: D (Periodic testing and checking of battery expiry, ensuring the prescribed standby and operating time)
💡 SOLAS requires periodic testing of the SART and checking of its battery condition and expiry, ensuring the prescribed standby and operating periods. An unsuitable battery means the searching radar cannot detect the survival craft.
✗
Question 41. What is the purpose of heading repeaters for the gyro compass?
Your Answer: (Not answered)
Correct Answer: B (To repeat the heading at positions where it is needed, such as the steering and emergency steering positions)
💡 SOLAS requires heading repeaters at the main steering and emergency steering positions so that the helmsman can read the heading without leaving his station, ensuring accurate steering.
✗
Question 42. Which certificates may a recognized organization issue on behalf of the Administration?
Your Answer: (Not answered)
Correct Answer: A (Statutory certificates such as the Passenger Ship Safety Certificate)
💡 A recognized organization may be entrusted with statutory surveys and certification.
✗
Question 43. What is the purpose of the towing and mooring equipment information required by SOLAS II-1/3-9?
Your Answer: (Not answered)
Correct Answer: B (To enable the crew to know the safe working load and limitations of the equipment and prevent injury during mooring)
💡 SOLAS II-1/3-9 requires information on the arrangement, number and safe working load of towing and mooring equipment to be kept on board for safe operation and maintenance.
✗
Question 44. If a ship fails a survey because of an equipment deficiency, what may the Administration do?
Your Answer: (Not answered)
Correct Answer: B (Require rectification within a period and re-inspect afterwards, with the validity of the certificate possibly affected meanwhile)
💡 SOLAS I/12 permits the Administration to suspend or withdraw a certificate where the ship does not comply. In practice rectification within a period and re-inspection is required before validity is maintained or restored. A certificate must not be issued with a deficiency outstanding.
✗
Question 45. What analysis and records are required if a voyage plan is not followed exactly?
Your Answer: (Not answered)
Correct Answer: B (Analyse the cause, such as avoidance, sheltering or a fault, assess the effect and record it, revising the plan if necessary)
💡 Where the execution of a voyage plan deviates, the reason should be analysed, whether avoidance, sheltering, an equipment fault or a temporary task, the effect on the remaining passage and safety assessed and the matter recorded, with the remaining plan revised as appropriate, such as updating waypoints or adjusting timing, keeping the plan consistent with what is being done.
✗
Question 46. The second officer drafts the quarterly drill plan: "muster monthly, brief on the equipment, everyone to the station, no boat actually lowered." Measured against the SOLAS chapter III drill frequencies, what is missing?
Your Answer: (Not answered)
Correct Answer: A (every lifeboat should be launched with its assigned crew at intervals not exceeding 3 months and manoeuvred with them, and launched with at least two crew at intervals not exceeding 6 months)
💡 The frequencies are easy to mix up: launching with the assigned crew and manoeuvring at intervals within 3 months, launching with two or more crew within 6 months. The monthly abandon-ship and fire drill is a separate layer and neither substitutes for the other, and an annual survey of the appliances says nothing about the crew's ability to get the boat down.
✗
Question 47. With regard to spare antennas:
Your Answer: (Not answered)
Correct Answer: C (a spare antenna shall be provided so that it can be rigged if the main antenna is damaged)
💡 SOLAS IV/13 requires a spare antenna capable of being rigged if the main antenna is damaged.
✗
Question 48. What minimum duration of air supply does SOLAS II-2/10.1 require for the self-contained compressed air breathing apparatus of a firefighter's outfit?
Your Answer: (Not answered)
Correct Answer: A (30 minutes)
💡 SOLAS II-2/10.1 requires the self-contained breathing apparatus to have a capacity of at least 30 minutes of air. Do not confuse this with the 3-hour electric safety lamp or the 30 m lifeline.
✗
Question 49. What action do SOLAS and STCW require if the main engine fails while under way?
Your Answer: (Not answered)
Correct Answer: A (Notify the bridge immediately, display the appropriate lights, shapes or sound signals and take action such as anchoring or other avoidance measures)
💡 Engine failure deprives the ship of manoeuvrability. The bridge must be informed at once, the lights, shapes or signals for a vessel not under command displayed, and measures such as anchoring taken to avoid collision, with the authorities informed.
✗
Question 50. What factors must be considered in preparing a solid bulk cargo loading plan?
Your Answer: (Not answered)
Correct Answer: B (Hull strength and stability limits, the weight per hold and the loading sequence, and the properties of the cargo)
💡 The IMSBC Code and SOLAS require the loading plan to take account of hull strength and stability limits, the maximum weight per hold and restrictions on adjacent holds, the sequence of loading and discharging and the properties of the cargo, such as density and moisture content, with the approved sequence followed.
✗
Question 51. What must be carefully considered when loading high density cargo into a bulk carrier?
Your Answer: (Not answered)
Correct Answer: C (Hull structural strength and the loading rate)
💡 Hull structural strength and the rate of loading must be controlled.
✗
Question 52. For a cargo ship, the pressure at any hydrant below the maximum breadth shall be not less than:
Your Answer: (Not answered)
Correct Answer: A (0.2 N/mm² (2 bar))
💡 SOLAS II-2/10 requires a pressure of not less than 0.2 N/mm² (2 bar) at any hydrant below the maximum breadth of a cargo ship.
✗
Question 53. What is the basic principle for the provision of lifejackets?
Your Answer: (Not answered)
Correct Answer: D (One for every person on board, with additional ones for watchkeepers, remote locations and survival craft stations)
💡 Under SOLAS III/7 and III/32 a lifejacket should be provided for every person on board, with additional ones to meet the needs of watchkeeping positions, remote locations and survival craft stations, so that one can be obtained at any time and place.
✗
Question 54. What does SOLAS address regarding automatic change-over of the radio reserve source?
Your Answer: (Not answered)
Correct Answer: D (The reserve source must connect automatically or be switched promptly according to procedure when the main source fails)
💡 SOLAS requires the radio reserve source to be connected automatically or switched promptly under the procedure when the main source fails, keeping distress communication capability uninterrupted. A change-over needing lengthy manual action would interrupt emergency communication.
✗
Question 55. The anniversary date for the annual survey is 15 June. What is the proper window?
Your Answer: (Not answered)
Correct Answer: B (Between March and mid-September, that is within three months before or after the anniversary)
💡 SOLAS sets the window for the annual survey at three months before and after the certificate anniversary, so 15 June gives 15 March to 15 September. A survey outside the window makes the certificate invalid, while one too early does not advance the next due date.
✗
Question 56. What does SOLAS address regarding marking of escape routes?
Your Answer: (Not answered)
Correct Answer: C (Clear marking identifiable in dense smoke, indicating the way to muster and embarkation stations)
💡 SOLAS requires escape routes to be clearly marked in a form identifiable in dense smoke, such as low level lighting or photoluminescent markings, showing the way to the muster and embarkation stations so that personnel can find the exit in very poor visibility.
✗
Question 57. What must the cargo information provided by the shipper include under SOLAS and the IMSBC Code?
Your Answer: (Not answered)
Correct Answer: A (The cargo name, group, stowage factor, trimming requirements and chemical hazards where applicable)
💡 SOLAS VI/1 and the IMSBC Code require information including the proper shipping name, cargo group, stowage factor, trimming requirements, moisture content and chemical hazards to be provided before loading, enabling the master to judge suitability and take the necessary precautions.
✗
Question 58. What safety is required for deck work at sea?
Your Answer: (Not answered)
Correct Answer: D (Safe working procedures including risk assessment, use of protective equipment and restrictions in heavy weather)
💡 SOLAS and the ISM Code require deck work such as checking securing, chipping and maintenance to follow safe working practices: a risk assessment before starting, covering ship movement, wind and sea, work at height and enclosed spaces, correct use of personal protective equipment and restriction or suspension of the work in heavy weather.
✗
Question 59. Regarding launching and recovery of survival craft:
Your Answer: (Not answered)
Correct Answer: B (training shall be given in both launching and recovery)
💡 SOLAS III/19 requires training in both launching and recovery of survival craft.
✗
Question 60. After a distress alert sent by digital selective calling, on which frequency is the follow-up distress traffic made?
Your Answer: (Not answered)
Correct Answer: D (very high frequency moving to sixteen, medium frequency to two thousand one hundred and eighty-two kilohertz)
💡 Selective calling only puts the alert and the position out; the channel itself is not for speech. A very high frequency alert goes out on seventy and the traffic that follows is made on sixteen; the medium frequency alert is sent on two thousand one hundred and eighty-seven and a half kilohertz with the traffic on two thousand one hundred and eighty-two, high frequency having its own distress and safety frequencies. An alert is normally acknowledged by radiotelephony, and acknowledgements and relays are made on the frequency the rules assign, the alerting channel being kept clear. Treating seventy as a speech channel confuses the calling and the telephony sides of the system.
✗
Question 61. What does SOLAS address regarding resetting fire detection alarms?
Your Answer: (Not answered)
Correct Answer: A (Alarms should be reset only after the fire condition has been cleared, preventing the mask of a real fire by careless resetting)
💡 SOLAS requires detection alarms to be reset only after the fire condition has been dealt with, preventing the watchkeeper from resetting alarms merely to silence them and thereby concealing a real fire with serious consequences.
✗
Question 62. Under SOLAS I/8, the flag State shall:
Your Answer: (Not answered)
Correct Answer: D (ensure compliance with the Convention and supervise its ships)
💡 SOLAS I/8: the flag State shall ensure compliance with the Convention and supervise its ships.
✗
Question 63. Which statement about the inspection and maintenance of davits is correct?
Your Answer: (Not answered)
Correct Answer: A (Their structure, sheaves, wire ropes and braking arrangements should be inspected regularly to ensure reliable launching with the boat at its permitted complement)
💡 Under SOLAS III/4 and related requirements davits and their launching appliances should be inspected regularly for structural integrity, the condition of the sheaves and wire ropes, the braking and limit arrangements and whether the boat can be launched reliably with its permitted complement. Inspection and maintenance records should be kept and defects rectified promptly.
✗
Question 64. The fire main pressure gauge shows an abnormally low pressure. What is the concern?
Your Answer: (Not answered)
Correct Answer: C (It may indicate reduced pump performance, leakage or a valve not properly opened and the cause should be established)
💡 Abnormally low pressure in the fire main may result from reduced fire pump performance, leakage in the piping or valves, a valve not correctly opened or a problem on the suction side. It would mean insufficient pressure at the jets in a fire, so the cause should be established and dealt with at once, as this is a deficiency that may affect firefighting capability.
✗
Question 65. What does SOLAS address regarding product certification of life-saving appliances?
Your Answer: (Not answered)
Correct Answer: C (Appliances must hold type approval or product certificates from a recognised body attesting compliance with the performance standards)
💡 SOLAS requires life-saving appliances to comply with the performance standards such as the LSA Code and to hold type approval or product certificates. Approval marks and certificates are checked at survey and PSC, and equipment without an approval mark may not be accepted.
✗
Question 66. What does SOLAS address regarding the position of survival craft relative to the propulsion plant?
Your Answer: (Not answered)
Correct Answer: D (Stowed as far as practicable from the propulsion plant and other hazardous areas, avoiding interference from propellers or exhaust)
💡 SOLAS requires survival craft to be stowed as far as practicable from the propellers, thrusters and exhaust areas, preventing injury to persons or damage to the craft during launching, and allowing safe launching even while the ship still has headway.
✗
Question 67. What do SOLAS and the related rules emphasise for position fixing in ice or polar waters?
Your Answer: (Not answered)
Correct Answer: A (Cross-check by several means, since compass and position fixing equipment may be affected by magnetic variation and signal conditions in polar regions)
💡 Magnetic variation is large in polar regions and satellite signals may be affected by ionospheric conditions. SOLAS and good seamanship require the position and heading to be cross-checked by several means, avoiding the risk from a single equipment error.
✗
Question 68. What does SOLAS and the Polar Code require regarding manning and training for polar waters?
Your Answer: (Not answered)
Correct Answer: A (The master and officers in charge of a navigational watch must have completed appropriate polar waters training and gained the required experience)
💡 SOLAS XIV and STCW require the master and officers in charge of a navigational watch of a ship in polar waters to have completed polar waters training appropriate to the ship's category and to have the prescribed seagoing experience, ensuring the ability to operate in polar conditions.
✗
Question 69. Who approves a permit to work?
Your Answer: (Not answered)
Correct Answer: C (The master or an authorised person, with the risk assessment and safety measures confirmed before the work starts)
💡 A permit to work should be approved by the master or an authorised responsible person, the approval being given after confirming that the risk assessment is complete and the safety measures, including gas testing, ventilation, standby, protection and emergency preparation, are in place and conditions are suitable, remaining valid and supervised while the work proceeds.
✗
Question 70. What is the purpose of the radar reflector among the lifeboat equipment?
Your Answer: (Not answered)
Correct Answer: C (To increase the radar echo of the boat so that it is detected by searching vessels)
💡 SOLAS requires a lifeboat to carry a radar reflector, increasing the radar echo so that searching vessels detect the boat at a greater distance, improving the chance of rescue.
✗
Question 71. How should a lifeboat be launched?
Your Answer: (Not answered)
Correct Answer: D (Controlled from within the boat (gravity davit) with the lowering speed controlled and the boat kept steady)
💡 A lifeboat is launched under control from within the boat, with a release arrangement in the boat for a gravity davit. The lowering speed should be controlled, contact with the ship's side prevented and the boat turned and cleared for release before entering the water. Too fast a descent causes casualties and structural damage.
✗
Question 72. When children are carried on board, how must children's lifejackets be provided?
Your Answer: (Not answered)
Correct Answer: A (In number equal to the number of children on board, plus a number of spares)
💡 SOLAS III/7.1 requires children's lifejackets equal to the number of children carried, plus spares. Adult lifejackets are not an acceptable substitute.
✗
Question 73. Boundaries of machinery spaces shall be constructed of:
Your Answer: (Not answered)
Correct Answer: C (A class divisions)
💡 SOLAS II-2/9 requires machinery space boundaries of A class divisions.
✗
Question 74. What does SOLAS address regarding the two steel ladders forming the means of escape from a machinery space?
Your Answer: (Not answered)
Correct Answer: A (The two ladders must be distant from each other, one of which may be enclosed, so that one remains usable if the other is blocked)
💡 SOLAS requires two means of escape from a category A machinery space, distant from each other, normally two steel ladders one of which may be enclosed, so that personnel can withdraw by the other if one exit is blocked by fire or smoke. Adjacent ladders or a common exit would put both out of use at once.
✗
Question 75. What do SOLAS and STCW address regarding drills for recovering a person from the water?
Your Answer: (Not answered)
Correct Answer: D (Practical drills including launching and recovering the rescue boat, so the crew is familiar with the procedure)
💡 SOLAS and STCW require drills so that the crew is familiar with the procedure for recovering a person overboard, including raising the alarm, keeping the person in sight, manoeuvring the ship back and launching and recovering the rescue boat, so that an actual recovery is prompt and orderly.
✗
Question 76. What arrangements does SOLAS permit to ensure the availability of radio equipment in sea areas A1 and A2?
Your Answer: (Not answered)
Correct Answer: A (Duplication of equipment, a shore-based maintenance agreement, or at-sea maintenance capability — one of the three)
💡 SOLAS IV/15 allows availability to be ensured by duplication of equipment, a shore-based maintenance contract or at-sea maintenance capability, used singly or in combination.
✗
Question 77. The total capacity of the fire pumps on a cargo ship shall not be less than:
Your Answer: (Not answered)
Correct Answer: C (the required capacity of each pump)
💡 SOLAS II-2/10 requires the total capacity of fire pumps on a cargo ship to be not less than the required capacity of each pump.
✗
Question 78. Which Code governs the classification of dangerous goods?
Your Answer: (Not answered)
Correct Answer: D (The IMDG Code)
💡 The IMDG Code.
✗
Question 79. What should be done if a watertight door cannot be closed after damage?
Your Answer: (Not answered)
Correct Answer: A (Take measures to plug or otherwise limit the flooding, assess stability and decide the further course of action)
💡 A watertight door that cannot be closed allows flooding to spread. Measures to plug it, such as with leak-stopping material or wedges, or to limit the flooding should be taken at once, the stability and rate of flooding assessed and the further course decided, whether to beach, pump out or seek outside assistance, with the company informed.
✗
Question 80. What is the purpose of the water ingress detection system required on a bulk carrier?
Your Answer: (Not answered)
Correct Answer: B (To give an alarm when water enters the cargo holds and fore and aft spaces, enabling the crew to detect and deal with it promptly)
💡 Under SOLAS XII/12 a bulk carrier should have water ingress detection and alarm systems for the cargo holds and the forepeak and similar spaces, giving an alarm on the bridge promptly when water enters so that the crew can detect the ingress early and take pumping, leak-hunting and damage control measures, preventing the situation from worsening. The testing of the system should be kept effective.
✗
Question 81. If the master finds a defect affecting safe navigation that cannot be repaired on board, the first action is to:
Your Answer: (Not answered)
Correct Answer: A (Report to the Company and arrange repair)
💡 The master should report to the Company so that repair can be arranged and the voyage adjusted.
✗
Question 82. A VHF radio installation shall maintain a continuous watch on:
Your Answer: (Not answered)
Correct Answer: A (channel 16)
💡 SOLAS IV/7: a VHF installation shall maintain a continuous watch on channel 16 and, where required, on channel 70.
✗
Question 83. When a fixed CO2 system serves a machinery space, what key parameter does SOLAS address?
Your Answer: (Not answered)
Correct Answer: C (The quantity released must achieve the prescribed extinguishing concentration and the space must be reasonably gas-tight)
💡 SOLAS requires the CO2 quantity to be calculated from the volume of the space to achieve the prescribed concentration, and the space to be reasonably gas-tight so that leakage does not defeat the system.
✗
Question 84. How is the rated capacity of survival craft determined under SOLAS?
Your Answer: (Not answered)
Correct Answer: A (From the volume and floor area required per person and the design capacity of the craft)
💡 SOLAS prescribes the method of determining the rated capacity of survival craft, based on the minimum volume and floor area per person and the buoyancy and strength of the craft. Carrying more than the rated capacity seriously affects buoyancy and stability.
✗
Question 85. What does the weather criterion of the intact stability code examine?
Your Answer: (Not answered)
Correct Answer: B (a gust heeling lever added to that of the steady wind, the angle of heel and the downflooding angle retaining adequate margin)
💡 The criterion splits the wind into a steady pressure and a gust: the ship heels under the steady heeling lever and the gust pushes her further, the area under the righting lever curve having to exceed that under the wind levers, the gust heel staying within the fraction of the downflooding angle and inside the stated limit. Metacentric height or roll period alone cannot answer that question.
✗
Question 86. What is required for periodic running of lifeboat engines?
Your Answer: (Not answered)
Correct Answer: B (Run at least once each week for not less than the prescribed period, checking the cooling and fuel systems)
💡 SOLAS requires the lifeboat engine to be run at least once each week for not less than the prescribed period, bringing it to normal operating condition and checking the cooling and fuel systems. Long neglect leads to difficulty in starting and the engine may not work when genuinely needed.
✗
Question 87. What is required for the batteries of two-way VHF radiotelephones in survival craft?
Your Answer: (Not answered)
Correct Answer: D (Capacity meeting the required operating time, with periodic testing and replacement)
💡 SOLAS requires the batteries of two-way VHF sets to have capacity for the prescribed operating time, with periodic testing and replacement. Neglecting this means the equipment may not work on abandonment.
✗
Question 88. Under typical conditions (antenna height and SART height of 1 m), a SART should be detectable at a range of about:
Your Answer: (Not answered)
Correct Answer: D (5 nm)
💡 SOLAS IV/7: a SART should be detectable at a range of about 5 nautical miles under typical conditions.
✗
Question 89. What is the effect of contamination of a fire detector by oil fume or dust?
Your Answer: (Not answered)
Correct Answer: C (It may cause false alarms or reduced sensitivity leading to a missed alarm, so periodic cleaning and maintenance are required)
💡 A detector contaminated by oil, dust or moisture may give frequent false alarms or lose sensitivity and miss an alarm. It should therefore be cleaned and function tested at the prescribed intervals, especially in heavily contaminated spaces such as the galley and machinery space.
✗
Question 90. What must the line-throwing appliance achieve under SOLAS?
Your Answer: (Not answered)
Correct Answer: C (Throw a line not less than 230 m, with not fewer than four lines and four projectiles)
💡 SOLAS III/18 requires the line-throwing appliance to throw a line not less than 230 m, provided with four lines and four projectiles, for establishing contact with a casualty or the shore. Insufficient range or quantity reduces the rescue capability.
✗
Question 91. A fire drill must do more than muster and call names. What else has to happen?
Your Answer: (Not answered)
Correct Answer: D (mustering to the station bill and reporting, doors, dampers, outfits and communication examined, a fire simulated and water streamed)
💡 The drill has to be worked through for real: mustering to the station bill and reporting the numbers and the positions taken; fire doors and dampers closed and their closing confirmed; the firemen's outfits ready to be put on, the cylinders charged, the communication gear tested; a fire simulated, the way found and approached, the fire pump started and water streamed from a hydrant, so that pump, pipe, nozzle and people are proved together. A fire party drilling alone while the rest wait in their cabins, or a lecture in place of the exercise, tests nothing about the duties the station bill assigns and leaves a record no inspector can accept.
✗
Question 92. What is required of navigational equipment fitted on board?
Your Answer: (Not answered)
Correct Answer: B (That it complies with the applicable standards and remains in effective working order)
💡 It shall comply with applicable standards and remain in effective working order.
✗
Question 93. What safety is required in operating ballast system valves?
Your Answer: (Not answered)
Correct Answer: B (Valves clearly identified and operated in order, preventing misoperation causing cross-connection or cargo contamination)
💡 SOLAS and good practice require the valves of the ballast and bilge systems to be clearly identified and operated in a proper sequence, normally following the ballast plan, preventing an inadvertent opening from cross-connecting ballast and cargo tanks, contaminating cargo or causing a sudden change in stability.
✗
Question 94. What does SOLAS address regarding the protection of stairway enclosures?
Your Answer: (Not answered)
Correct Answer: D (Stairways must be enclosed by class A or B divisions, preventing a chimney effect from accelerating fire and smoke spread)
💡 SOLAS requires enclosed stairways in accommodation spaces to be protected by class A or B divisions, preventing the stairwell from acting as a chimney that accelerates the upward spread of flame and smoke, and protecting the escape route.
✗
Question 95. What analysis of accidents and near misses is required?
Your Answer: (Not answered)
Correct Answer: D (Report and analyse the root cause, take corrective action, assess the outcome and share the lesson)
💡 The ISM Code requires accidents and near misses, events that could have caused loss, to be reported and analysed for root cause, with corrective and preventive action taken, effectiveness assessed and the lesson shared on board and within the company, so that the warning is used and a near miss does not become an accident.
✗
Question 96. What is the position under SOLAS V and the related rules regarding responsibility when a pilot is on board?
Your Answer: (Not answered)
Correct Answer: B (The pilot advises; the master retains full responsibility for the safety of the ship)
💡 A pilot contributes local knowledge and handling expertise but commands no authority over the ship; the master retains overall responsibility and command for her safety.
✗
Question 97. What capacity is required for the fuel tank of the emergency generator?
Your Answer: (Not answered)
Correct Answer: A (Sufficient to run the emergency generator at full load for the prescribed period, normally not less than 18 hours)
💡 SOLAS requires the fuel tank of the emergency generator to hold enough fuel to run it at full rated load for the prescribed period, normally not less than 18 hours on a cargo ship, corresponding to the emergency lighting period, with the fuel of an acceptable flashpoint and able to feed properly at low temperature.
✗
Question 98. A magnetic compass deviation curve is found not updated within the required period. The finding is?
Your Answer: (Not answered)
Correct Answer: A (The magnetic compass must be swung and its deviation curve drawn periodically; being overdue makes the heading reference unreliable)
💡 The magnetic compass is one of the key heading references and should be swung and its deviation curve drawn at the required intervals, the deviation changing with the magnetic state of the ship. Being overdue means the indicated heading carries an unknown error. If relied on as the primary heading reference it may endanger navigational safety. It is a deficiency to be corrected.
✗
Question 99. The muster list is found not updated after crew changes and some duties are vacant. The finding is?
Your Answer: (Not answered)
Correct Answer: A (The muster list must match the crew on board; failure to update is an emergency preparedness deficiency)
💡 The muster list should set out the duties and muster station of each crew member in an emergency and be updated promptly with crew changes so that everyone knows their duty. Failure to update leaves some posts vacant and causes confusion in an emergency. It is a deficiency to be corrected.
✗
Question 100. What shall the training manual for life-saving appliances contain?
Your Answer: (Not answered)
Correct Answer: C (Instructions on the use of each appliance and survival information)
💡 Instructions on using each appliance and survival information.